dlg, test report 6137f, saccheria antonio consonni snc ... · pdf file20847...
TRANSCRIPT
DLG e.V.Test Center
Technology and Farm Inputs
DLG Test Report 6137 F page 1 of 2
DescriptionGrey thick woven cover for cow mattresses made of PET (Polyethylenterephthalat) and PP (Polypropylen), thickness approximately 1 mm.
AnmelderSaccheria Antonio Consonni SNC
Via G. Marconi 98/10020847 AlbiateMBItaly
Telephone: 0039 0362 930 204Telefax: 0039 0362 913 [email protected] / [email protected] www.saccheriaconsonni.it
Test results and detailed evaluationsPermanent tread load
For the test the cover muSAC gris was fixed on a foam made of Polyurethan (approximately 45 mm thick).
After the permanent tread load exerted by a round steel foot (artificial cow’s foot) having a diameter of 105 mm (contact area 75 cm², with a 5 mm wide ring at the periphery of the sole, which projects 1 mm over the rest of the surface (carrying edge of the claw) in test stand trials (100.000 alternating loads of 10.000 N (corresponding
Evaluation*
– little wear on the surface
* Evaluation range: ++ / + / / – / – – ( = standard)
to ca. 1000 kg), the cover muSAC gris showed little wear on the surface and no damage.
DLG Test Report 6137 F
Saccheria Antonio Consonni SNC
Cover muSAC grisPermanent tread load
ENTAM – European Network for Testing of Agricultural Machines, is the association of European test centres. ENTAM’s objective is the Europewide distribution of test results for farmers, agricultural equipment dealers, and producers.More information about the Network is available at www.entam.com or by writing to ENTAM at the email address: [email protected]
DLG Test Report 6137 F page 2 of 2
DLG e.V. – Test Center Technology and Farm InputsMaxEythWeg 1, 64823 GroßUmstadt, Germany Telephone 069 247 88600, Fax: 069 247 88690, Email: [email protected], Internet: www.DLG.org
Download all DLG test reports free of charge at: http://www.dlg.org/testsagriculture.html
12975July 2013© DLG
TestThe DLG Fokus Test included a permanent tread load on a test rig of the DLG test station. Other criteria were not tested.
The test was done in accordance to the DLG test program for elastic floors for animals, version april 2010.
Realization of the test
DLG e.V. –Test Center Technology and Farm Inputs,MaxEythWeg 1,64823 GroßUmstadtGermany
Reporting engineer
Dr. Harald Reubold
Project manager technique animals
Dipl.Ing. agr. Susanne Gäckler
Picture 3: sample after permanent tread load test
Picture 2: permanent tread load test