dlg, test report 6137f, saccheria antonio consonni snc ... · pdf file20847...

2
DLG e.V. Test Center Technology and Farm Inputs DLG Test Report 6137 F page 1 of 2 Description Grey thick woven cover for cow mattresses made of PET (Polyethylen- terephthalat) and PP (Polypropylen), thickness approximately 1 mm. Anmelder Saccheria Antonio Consonni SNC Via G. Marconi 98/100 20847 Albiate-MB-Italy Telephone: 0039 0362 930 204 Telefax: 0039 0362 913 237 [email protected] / [email protected] www.saccheriaconsonni.it Test results and detailed evaluations Permanent tread load For the test the cover muSAC gris was fixed on a foam made of Polyurethan (approximately 45 mm thick). After the permanent tread load exerted by a round steel foot (arti- ficial cow’s foot) having a diameter of 105 mm (contact area 75 cm², with a 5 mm wide ring at the peri- phery of the sole, which projects 1 mm over the rest of the surface (carrying edge of the claw) in test stand trials (100.000 alternating loads of 10.000 N (corresponding Evaluation* – little wear on the surface * Evaluation range: ++ / + / / – / – – ( = standard) to ca. 1000 kg), the cover muSAC gris showed little wear on the sur- face and no damage. DLG Test Report 6137 F Saccheria Antonio Consonni SNC Cover muSAC gris Permanent tread load

Upload: vuongphuc

Post on 13-Mar-2018

221 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: DLG, Test Report 6137F, Saccheria Antonio Consonni SNC ... · PDF file20847 Albiate­MB­Italy Telephone: 0039 0362 930 204 Telefax: 0039 0362 913 237 nfi o@saccheacri onsonnti.i

DLG e.V.Test Center

Technology and Farm Inputs

DLG Test Report 6137 F page 1 of 2

DescriptionGrey thick woven cover for cow mattresses made of PET (Polyethylen­terephthalat) and PP (Polypropylen), thickness approximately 1 mm.

AnmelderSaccheria Antonio Consonni SNC

Via G. Marconi 98/10020847 Albiate­MB­Italy

Telephone: 0039 0362 930 204Telefax: 0039 0362 913 [email protected] / [email protected] www.saccheriaconsonni.it

Test results and detailed evaluationsPermanent tread load

For the test the cover muSAC gris was fixed on a foam made of Polyurethan (approximately 45 mm thick).

After the permanent tread load exerted by a round steel foot (arti­ficial cow’s foot) having a diameter of 105 mm (contact area 75 cm², with a 5 mm wide ring at the peri­phery of the sole, which projects 1 mm over the rest of the surface (carrying edge of the claw) in test stand trials (100.000 alternating loads of 10.000 N (corresponding

Evaluation*

– little wear on the surface

* Evaluation range: ++ / + / / – / – – ( = standard)

to ca. 1000 kg), the cover muSAC gris showed little wear on the sur­face and no damage.

DLG Test Report 6137 F

Saccheria Antonio Consonni SNC

Cover muSAC grisPermanent tread load

Page 2: DLG, Test Report 6137F, Saccheria Antonio Consonni SNC ... · PDF file20847 Albiate­MB­Italy Telephone: 0039 0362 930 204 Telefax: 0039 0362 913 237 nfi o@saccheacri onsonnti.i

ENTAM – European Network for Testing of Agricultural Machines, is the association of European test centres. ENTAM’s objective is the Europe­wide distribution of test results for farmers, agricultural equipment dealers, and producers.More information about the Network is available at www.entam.com or by writing to ENTAM at the email address: [email protected]

DLG Test Report 6137 F page 2 of 2

DLG e.V. – Test Center Technology and Farm InputsMax­Eyth­Weg 1, 64823 Groß­Umstadt, Germany Telephone 069 247 88­600, Fax: 069 247 88­690, E­mail: [email protected], Internet: www.DLG.org

Download all DLG test reports free of charge at: http://www.dlg.org/testsagriculture.html

12­975July 2013© DLG

TestThe DLG Fokus Test included a permanent tread load on a test rig of the DLG test station. Other criteria were not tested.

The test was done in accordance to the DLG test program for elastic floors for animals, version april 2010.

Realization of the test

DLG e.V. –Test Center Technology and Farm Inputs,Max­Eyth­Weg 1,64823 Groß­UmstadtGermany

Reporting engineer

Dr. Harald Reubold

Project manager technique animals

Dipl.­Ing. agr. Susanne Gäckler

Picture 3: sample after permanent tread load test

Picture 2: permanent tread load test