HS-100, HS-150 HOTEL CARD KEY SWITCHES
Hotel Key Card
Significantly reduce energy consumption in hotel rooms
T a b l e o f C o n t e n t s
Overview
Features and Benefits
Energy Savings and Code Operation Design and Applications
Product Details
3
4-5
6-7
8-9
10-11
2
3
The new HS Series Card Key Switches from Watt Stopper/Legrand, leading innovator in energy efficient lighting controls, help the hospitality industry significantly reduce energy consumption in empty hotel rooms.
Whether it’s for comfort, safety orjust a response to the unfamiliarsurroundings, hotel guests arenotorious for leaving lights on inunoccupied rooms. To stem thisunnecessary waste of energy, the2006 IECC and ANSI/ASHRAE/IESNA Standard 90.1 both require all new hospitality rooms to include a master switch or control device at the main entry that controls permanently installed lighting and switched receptacles throughout the room.
The elegantly styled HS Card Key Switch easily complies with current energy codes,
saves on utility bills and improves guest comfort and convenience – all by providing a simple way to turn the room’s controlled lighting on or off at once when entering or exiting a room.
Operation couldn’t be simplerRegistered guests and housekeeping staff insert the room’s card key (or HS-FOB Key Fob for guest rooms that do not use a card
key) into the Card Key Switch and the room’s controlled circuits become energized. When the card key or Key Fob is removed, thecontrolled circuits will turn off after 30 seconds, allowing for safe egress from the room.
The HS series Card Key Switches are ideal for hotels, motels, inns, boarding houses, senior residences and other similar facilities.
No morelights onin empty
guest rooms!
while improving guest comfort and convenience
4
Masterfully engineered with the hotel facility manager and guest in mind
About 50% of energy used in the hotel isin guest rooms.* And studies show thathotel lighting usage patterns do not reflect a significant dip in energy consumption during 11 A.M. to 5 P.M. when guest rooms are typically unoccupied. Rather, researchers have found that guest room lights are on 20-25% of the time during this time period.
Watt Stopper’s HS Series Card Key Switches will positively impact the energy management behavior of housekeeping staff and guests without the need for any special training, offering a significantopportunity to achieve maximum energy
savings during the day when peak load rates are highest.
9
8
7
6
5
4
3
2
1
0
Bathroom Light
DeskTable Lamp
BedsideTable Lamp
Average Hours per Day On Time
Hou
rs /
Day
FloorLamp
Torchiere
SOURCE: “Lighting Energy Savings Opportunities in Hotel Guestrooms” (research study, Redondo Beach Crowne Plaza, Oct. 1999)Erik Page and Michael Siminovitch, Lighting Research Group, Building Technologies Dept., Lawrence Berkeley National Laboratory
This chart illustrates a pattern of wasteful energy consumption.
Average Hours of Operation Per Day for Various Fixture Types
*Hotels Magazine, April 2001. www.hotelsmag.com
5
• Attractive, low-profile styling enhances even the finest decor.
• LED illuminated card key slot for easy visibility in darkened rooms.
• Five decorator colors coordinate with any room design.
• Unlike a master wall switch, all controlled electrical loads turn off automatically when guests leave the room, a convenience they appreciate.
• Card Key Switch’s 30-second egress time ensures guest safety.
• Since guests need their card keys to
power lights in their room, they’ll never
lose track of their card key again!
HS-100• Low voltage unit• Normally open/normally closed isolated
relay• Interfaces with third-party energy and/or
lighting management control systems.• Connects to one or more Watt Stopper
Power Packs.
HS-150• Line voltage unit• Serves as a master switch for a single
guest room circuit.
The right choice for energy savings in hotel rooms — line or low voltage models available
6
Satisfy energy codesCurrent requirements in both the 2006 IECC and ANSI/ASHRAE/IESNA Standard 90.1-2004 and 2007 require all new hospitality rooms and those installing new lighting systems to include a master switch or control device at the main entry that controls permanently installed lighting and switched receptacles throughout the room.
Save energyThe ability to control electrical circuits from one HS Series Card Key Switch ensures reliable energy savings.
Support ‘green’ living HS Series Card Key Switches can help earn credits for LEED NC 2.2 certification. A hotel designed with practical, energy-efficient standards can be marketed to environmentally-conscious consumers, and may help increase occupancy rates.
Lower operating expensesUsing less energy means real savings on your energy bills, especially controlling consumption during peak load hours when rates are highest. Your light bulbs will last longer from less use, and you’ll save money on their replacement and the labor for installing them.
Specifics of the current energy codesWhat buildings must comply with the energy codes?The energy codes apply to all new guest room facilities, new portions of those facilities and new systems and equipment in existing facilities.
IECC* 2006, 505.2.3: “Sleeping unit. Sleeping units in hotels, motels, boarding houses or similar buildings shall have at least one master switch at the main entry door that controls all permanently wired luminaires and switched receptacles, except those in the bathroom(s). Suites shall have a control meeting these requirements at the entry to each room or at the primary entry to the suite.”
ANSI/ASHRAE/IESNA** Standard 90.1-2004: “hotel and motel guest rooms and guest suites shall have a master control device at the main entry that controls all permanently installed luminaires and switched receptacles.”
ANSI/ASHRAE/IESNA** Standard 90.1-2007 with Addenda: “Guest rooms in hotels, motels, boarding houses or similar buildings shall have one or more control devices(s) at the entry door that collectively control all permanently installed luminaires and switched receptacles, except those in the bathroom(s). Suites shall have control(s) meeting these requirements at the entry to each room or at the primary entry to the suite. Bathrooms shall have a control device installed to automatically turn off the bathroom lighting, except for night lighting not exceeding 5 watts, within 60 minutes of the occupant leaving the space.”
* International Energy Conservation Code** American National Standards Institute/American Society of Heating, Refrigerating and Air Conditioning Engineers/Illuminating Engineering Society of North America
Simple solution to code compliance
7
And since guests need their key cards to power lights
in their rooms, they’ll never lose track of their key cards again!
• Easily locate the illuminated HS Series
Card Key Switch, even in a darkened
room.
• Insert the hotel room’s card key (or
HS-FOB) into the HS Series Card Key
Switch.
• The controlled circuits become
energized.
• Remove the card key (or HS-FOB).
• The controlled circuits will have power
for another 30 seconds to allow safe
egress from the room before power
turns off.
• Restore power to the room’s controlled
circuits by reinserting the hotel card key
into the Card Key Switch.
Operation couldn’t be simpler
8
HS Card Key Switches are ideal
control devices for guest rooms in
hotels, motels, inns, boarding houses,
senior residences or similar buildings. When
installed near the main entry door, an HS Card
Key Switch can control the permanently installed
luminaires and switched receptacles as required by
some energy codes. If your state follows the IECC
or ANSI/ASHRAE/IESNA Standard 90.1-2007, the
bathroom circuits do not need to be controlled by
the Card Key Switch.
When bathrooms are not controlled
by the Card Key Switch, maximize
your energy savings by adding a Watt
Stopper/Legrand WN-100 PIR Nightlight
Wall Switch Sensor to control bathroom lighting
based on occupancy. The WN-100’s nightlight
remains on when lights are off, providing constant
illumination that deters the need to leave overhead
lighting on all night. For more information on the
WN-100, go to www.wattstopper.com, or request
our new Product Selection Guide.
9
And while your guests are
away from their rooms,
they’re actually saving
you valuable energy and
reducing your energy bill.
Ca
rd
Ke
y S
wit
ch
OC
CU
PA
NC
Y
SE
NS
OR
S
10www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5
Product Overview
Features
The HS Series Card Key Switch turns electrical circuits on or off when a card key or HS-FOB Key Fob is inserted or removed from its slot. The HS-100 is a low voltage unit with a normally open and normally closed isolated relay, allowing it to interface with third-party energy and lighting management control systems. Additionally, the HS-100 can connect to one or more Watt Stopper Power Pack(s). The HS-150 is a line voltage unit that serves as a master switch for a single guest room circuit.
HS Series Card Key Switches
PROJECT
LOCATION/TYPE
30-second egress time
Line and low voltage models
• Attractive. low-profile styling
• Choice of five decorator colors
• Backlit card key slot provides visibility in darkened rooms
• 30-second egress time delay
• Zero crossing for reliability and increased product longevity (HS-150)
• HS-100 can connect with one or more Watt Stopper Power Packs
Code Compliance
Applications
HS Card Key Switches are ideal for guest rooms in hotels, motels, boarding houses, senior residences or similar applications with guest rooms. Once installed, they function as control devices located at the main entry door, controlling all permanently installed luminaires and switched receptacles.
Operation
Inserting a door entry card key or HS-FOB into the HS Card Key Switch energizes the controlled circuits and loads. Removing the card key initiates a 30-second time delay to allow safe egress from the hotel room. Once this time delay elapses, the power to the circuits is terminated. To restore power to the room’s controlled circuits, reinsert the card key into the HS Card Key Switch.
Description
• Uses the same card key that unlocks the door
• More effective compliance with code than a simple master wall switch, as only the HS Card Key Switch ensures that lights are off when the room is vacant
• Compliant with current requirements in both the IECC and ANSI/ASHRAE/IESNA Standard 90.1
• Compatible with Building Automation Systems, Energy Management Systems, and Lighting Control Panels
Backlit card key slot for visibility in darkened rooms
Ideal for guest rooms in hotels, motels and boarding houses
HS Card Key Switches provide an easy solution to current requirements in both the IECC and ANSI/ASHRAE/IESNA Standard 90.1, which now require a master switch at the entrance of every new guest room to control the room’s electrical circuits. Unlike a simple master switch, the HS Series Card Key Switches ensure that lights are off when a room is vacant for more reliable energy savings.
Optional key fob for guest rooms that do not use a card key
OC
CU
PA
NC
Y
SE
NS
OR
SC
ar
d K
ey
Sw
itch
11
Installation& Wiring
Pub. No. 27002
Ordering Information
Specifications
www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5
HS-100 Wiring with Power Pack HS-150 Wiring
Catalog No. Color Description
One HS-WP included with each Card Key Switch
Accessories
HS-100-W
HS-100-LA
HS-100-I
HS-100-B
HS-100-G
White
Light Almond
Ivory
Black
Gray
HS-150-W
HS-150-LA
HS-150-I
HS-150-B
HS-150-G
White
Light Almond
Ivory
Black
Gray
Catalog No. Color Description
Low voltage Card Key
Switch
Line voltage Card Key
Switch
HS-WP-W
HS-WP-LA
HS-WP-I
HS-WP-B
HS-WP-G
HS-WPR-W
HS-WPR-LA
HS-WPR-I
HS-WPR-B
HS-WPR-G
HS-WPL-W
HS-WPL-LA
HS-WPL-I
HS-WPL-B
HS-WPL-G
White
Light Almond
Ivory
Black
Gray
White
Light Almond
Ivory
Black
Gray
White
Light Almond
Ivory
Black
Gray
Optional Key Fob for
guest rooms that do not
use a Card Key Switch
Cover plate for single-
gang box
Cover plate for three- gang box with decorator switch option; card slot on the right
Cover plate for three- gang box with decorator switch option; card slot on the left
• HS-100: Input: 24VDC/24VAC Half Wave Rectified, Max. 25mA DC/10mA AC
Output: 1A/30VDC/VAC SPDT Isolated Relay• HS-150: 120-277 VAC; 50/60Hz, 2.1W Relay Output @120VAC: 0-800W tungsten,
0-600W ballast, 500W compact fluorescent, 1/6hp
Relay Output @277VAC: 0-1200W ballast• Zero crossing (HS-150)
• Compatible with building automation/energy management systems, lighting control panels and Watt Stopper power packs
• Dimensions: 2.63” x 1.69” x 1.88” (67.8mm x 42.9mm x 47.8mm) L x W x D
Accepts standard hotel card keys with dimensions of: 2.125”W x 3.375”H x 0.034”D (53.975mm x 85.725mm x 0.8636mm)
• Egress time delay: 30 seconds• UL and CUL listed; five-year warranty
HS-100 with BAS or LCP Cover Plates and Key Fob
(161.65mm)
6.36”
HS-WPHS-FOB HS-WPL
HS-FOB-W
HS-FOB-LA
HS-FOB-I
HS-FOB-B
HS-FOB-G
White
Light Almond
Ivory
Black
Gray
White (Neutral)
WhiteNeutral
BlackHot/Line
Whi
te
Red *(Load)
Local OFFswitches
Controlled receptacles inside the room
Lightingload
Lightingload
Lightingload
* Do not exceed the HS-150’s maximum load rating.
08363r1
Santa Clara, CA800.879.8585
Model #
HS-150Card Key Switch120-277VAC, 50/60HzRelay Output:0-800W tungsten/ballast, 1/6hp@120VAC0-1200W ballast, 1/4hp@277VACIndoor use only
GROUNDAPPLIANCECONTROL
88T9
(161.65mm)
6.36”
(119.38mm)
4.7”
(119.38mm)
4.7”
HS-WPR
(67.8mm)
2.63”
(85.5mm)
3.37”
(63.8mm)
2.51”
Corporate Headquarters2800 De La Cruz Blvd.Santa Clara, CA 95050
Tech Support: 800.879.8585www.wattstopper.com
WS-
08-2
0084
CAD Resource Center Over 300 CAD drawings from which to choose Wiring diagrams you can place in your own CAD drawings Available at www.wattstopper.com
Support & Services Commission and start-up services District managers, trained representatives and experts
available to answer all technical questions
Continuing Education Courses throughout North America qualify for AIA/CES
Health, Safety and Welfare (HSW) credit and NCQLP Lighting Education Units (LEUs)
In-person and on-line events Course selection available at www.wattstopper.com
Product Selection Guide Compilation of product ordering information, cut sheets,
design and application assistance
Watt Stopper/Legrand Resources & Tools