Contents
Reduced Voltage Motor Starters 1
Red
uce
d V
olt
ag
eM
oto
r S
tart
ers
Description Page
Type S811, Intelligent Technologies
(
IT.
)
Soft Starters with DIM
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
Instructional Leaflets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
IT.
Solid-State Soft Starters — Enclosed
Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
Non-combination
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
Combination with Fusible Disconnect
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
Combination with Breaker
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
Note:
Supplement to Publication No. CA08102001E — Tab 39.
S811 IT. Soft Starter
April 2007
2
For more information visit:
www.eaton.com
CA03902004E
Reduced Voltage Motor StartersSolid-State Starters
Type S811, Intelligent Technologies
(IT.)
Soft Starters with DIM
Contents
Description Page
Type S811, Intelligent Technologies
(
IT.
)
Soft Starters with DIM
Product Description . . . . . . .
2
Application Description . . . .
2
Features and Benefits . . . . . .
4
Operation . . . . . . . . . . . . . . .
7
Catalog Number Selection . . . . . . . . . . . . . . .
8
Product Selection . . . . . . . . .
9
Options . . . . . . . . . . . . . . . . .
19
Accessories . . . . . . . . . . . . . .
19
Standards and Certifications . . . . . . . . . . .
20
Instructional Leaflets . . . . . .
20
Technical Data andSpecifications . . . . . . . . . . .
21
Dimensions . . . . . . . . . . . . . .
22
Product Description
Eaton’s Cutler-Hammer
®
IT.
S801 revolutionized the reduced voltage control marketplace with its advanced feature set and small size. In fact, readers of an industry leading control publication rated Cutler-Hammer Soft Starters best in customer satisfaction in March 2004 and April 2006. The new
IT.
S811 from Eaton’s electrical busi-ness offers all the popular features of the S801, but adds enhanced function-ality with the new DIM (Digital Inter-face Module), communications, metering, monitoring and diagnostics capabilities.
The Cutler-Hammer Intelligent Technologies (
IT.
) Line of S811 Reduced Voltage Soft Starters is very compact, multi-functional, easy to install and easy to program. Designed to control the acceleration and deceleration of three-phase motors up to 690V, the line is available from 11 amps through 1,000 amps.
The S811 is designed to be a complete package combining the SCRs, bypass contactor and overload in one, very compact unit. The S811 is available as a component for panel mounting, in motor control centers or in enclosed control (NEMA Type 1, 3R, 4, 4X, 7/9 and 12).
Application Description
Designed to control the acceleration and deceleration of three-phase motors, the
IT.
S811 soft starter uses Silicon Controlled Rectifiers (SCRs) to control the voltage to soft start and soft stop the motor. After the motor is started, internal run bypass contactors close, resulting in the motor running directly across-the-line. The built-in solid-state overload protects the motor from overload conditions with sophis-ticated algorithms that model true motor heating, resulting in better motor protection and fewer nuisance trips. Advanced protective and diag-nostic features reduce downtime.
A voltage ramp start or current limit start is available. Kick start is available in either starting mode. The soft stop option allows for a ramp stop time that is longer than the coast to stop time. The pump control option provides a smooth transition for starting and stopping a motor and eliminating the “water-hammer” effect that can damage pipes, valves and pumps.
The S811 offers an impressive array of advanced protective features. Not only are the protective features selectable, but many offer variable settings allow-ing the user to fine tune the starter to meet specific system requirements.
The S811 has an easy to use Digital Interface Module (DIM) that allows the user to configure the device and to read system parameters. The DIM includes an LCD display and keypad to scroll through the various menus. The DIM allows the user to modify control parameters, enable or disable protec-tions, set communication variables, monitor system parameters such as line voltages and currents, and access the fault queue.
Figure 1. Digital Interface Module (DIM)
The DIM can be removed from the S811 and remote mounted. Kits are available to door mount the DIM, enabling users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclosure door. This will help eliminate the possibility of an arc flash incident.
S811 Open Soft Starter
ESC
ONLN SS OXFDO1 H STOP
Monitoring
PREV NEXT ENTER
April 2007
CA03902004E For more information visit:
www.eaton.com
3Reduced Voltage Motor StartersSolid-State Starters
Type S811, Intelligent Technologies
(IT.)
Soft Starters with DIM
Communications
The S811 has built-in communication capabilities through Cutler-Hammer QC (Quick Connect) Port. QCPort enables the soft starter to be con-nected to a variety of networks, includ-ing DeviceNet™, EtherNet/Modbus, EtherNet/IP and PROFIBUS. The advantage of QCPort is that multiple control components can be connected to one Cutler-Hammer
IT.
D77D gate-way. The gateway concentrates data from the devices into a single node. Configuration is simple — a single press of the gateway’s Auto Configura-tion button sets the system up for default operation. This automatically configures the I/O assemblies to the QCPort system devices. The data from these devices are then assembled into single input and output messages.
The S811 communication parameters can be configured with the DIM or through the fieldbus using CH Studio Component Manager. Advanced communication configuration settings provide the system integrator with powerful tools to facilitate system optimization.
Figure 2. S811 Connection Diagram
Table 1. Communications Reference
�
See Tab 50 of CA08102001E.
�
See Tab 44 of CA08102001E.
FieldBus
DIM
NetworkAdapter
(Gateway)
Terminator&
Power Tap
DIN RailCommunications
Backplane
24V DCPowerSupply
+– 1 0
IT. S811 Soft Starter
Description PartNumber
CatalogPage
DeviceNet Network Adapter
D77D-DNA
�
EtherNet Modbus Network Adapter
D77D-EMA
�
EtherNet/IP Network Adapter
D77D-EIP
�
PROFIBUS Network Adapter
D77D-PNA
�
Terminator and Power Tap
D77E-QPLR
�
DIN Rail Communications Backplane, 7-position
D77E-BP7
�
DIN Rail Communications Backplane, 12-position
D77E-BP12
�
24V DC Power Supply (120V AC Input)
PSS55A
�
24V DC Power Supply (240V AC Input)
PSS55B
�
24V DC Power Supply (480V AC Input)
PSS55C
�
April 2007
4
For more information visit:
www.eaton.com
CA03902004E
Reduced Voltage Motor StartersSolid-State Starters
Type S811, Intelligent Technologies
(IT.)
Soft Starters with DIM
Features and Benefits
■
The DIM (Digital Interface Module) provides an intuitive, easy-to-use human interface with powerful con-figuration capabilities to maximize system performance.
■
Door or device mounted DIM enables users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclo
sure door, eliminating the possibility
of an arc flash incident.
■
System operating parameters can be monitored enterprise-wide through a communications network. Increase uptime by providing data for process management and preventive diagnostics.
■
Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs. Bypass contactor directly connects the motor to the line and improves system efficiency by reducing internal power losses.
■
Internal solid-state overload protec-tion provides accurate current mea-surement and trip settings. Sophisticated algorithms solve a series of differential equations that model true motor heating and cool-ing, resulting in superior motor overload protection while minimiz-ing nuisance trips. Advanced select-able protective features safeguard the motor and system against a variety of system faults.
■
Internal run bypass contactors and overload protection eliminate the need for additional devices, reduc-ing enclosure sizes, minimizing installation and wiring time and reducing overall assembly size and cost.
■
Wide range of overload FLA settings (31 – 100% of rated current) and a selectable trip class (5 – 30) offers users the flexibility to fine tune the starter to match specific application requirements.
■
Variable ramp times and torque con-trol settings provide unlimited start-ing configurations, allowing for maximum application flexibility.
■
Kick-start feature enables soft start-ing of high friction loads.
■
Soft stop control for applications where an abrupt stop of the load is not acceptable.
■
Pump control option with sophisti-cated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer. The pump control option will maximize the life of the pump and piping systems while minimizing the downtime caused by system failure.
■
Six SCRs control all three motor phases, providing smooth accelera-tion and deceleration performance.
■
Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings.
■
Reduce the peak inrush current’s stress on the power system.
■
Minimize peak starting torque to diminish mechanical system wear and damage.
■
24V DC control module enhances personnel and equipment safety.
■
Removable, lockable control termi-nal block reduces maintenance costs. Also provides the opportunity for OEMs to reduce assembly and test costs by utilizing pre-assembled wire harnesses.
Protective Features
All protective features can be config-ured, enabled or disabled with the DIM or through the communications network.
Motor Overload
The S811 includes electronic overload protection as standard. The overload meets applicable requirements for a motor overload protective device. The overload protects the motor from over heat conditions with the use of sophisti-cated algorithms that model true motor heating, resulting in superior motor protection and fewer nuisance trips.
The S811 calculates a thermal memory value. A 100% value represents the maximum safe temperature of the motor. When the thermal memory value reaches 100%, an overload trip will occur removing power to the motor. Upon trip, the S811 stores the calculated motor heating value and will not allow a motor re-start until the motor has sufficiently cooled. This fea-ture ensures the motor will not be damaged by repeated overload trip, reset and re-start cycles.
The thermal memory value can be monitored through the DIM or the communications network. The thermal memory value can be of great use in determining an impending overload trip condition. Alarms can be imple-mented in the process monitoring system warning of an impending trip before a trip occurs halting the pro-cess. Costly system downtime can be avoided.
The trip current is adjusted to match the specific application requirements by entering the motor nameplate full load current rating and trip class. The FLA adjustment includes a 3 to 1 adjustment range. The overload trip class is adjustable from class 5 through class 30. The overload is ambient temperature compensated — meaning its trip characteristics will not vary with changes in ambient temperature. The overload protection can be enabled, disabled, or disabled on start.
Short Circuit
The use of a short circuit protective device in coordination with the S811 is required in branch motor circuits by most electrical codes. Short circuit coordination ratings with both fuses and Cutler-Hammer molded case cir-cuit breakers are available providing customers with design flexibility. The S811 has short circuit coordination ratings as an open component, an enclosed starter, and in a motor control center.
Jam
Excessive current and torque up to locked rotor levels can occur in a jam condition. The condition can result in stress and damage to the motor, load, mechanical system, and the electrical distribution system. Jam protection prevents the stress and damage from a jam during normal run. After the motor is started, a current greater than 300% FLA setting will cause the starter to trip on a jam fault.
April 2007
CA03902004E For more information visit:
www.eaton.com
5Reduced Voltage Motor StartersSolid-State Starters
Type S811, Intelligent Technologies
(IT.)
Soft Starters with DIM
Stall
Excessive current and torque up to locked rotor levels can occur in a stall condition. The condition can lead to an overload trip and result in stress and damage to the motor, load, mechani-cal system, and the electrical distribu-tion system. Stall protection prevents stress and damage to a motor that has not come up to speed, or stalled after the soft start time. The S811 will trip to protect the system in the event that the motor did not get to the rated speed in the defined soft start period. A current greater than 200% FLA at the end of the soft start period will cause the starter to trip on a stall fault.
Pole Over Temperature
High ambient temperatures, extended ramp times and high duty cycle condi-tions may cause the S811 power pole conductors to reach a temperature that exceeds their thermal rating. The S811 is equipped with sensors that monitor the temperature of the power poles. Over temperature protection occurs if the device’s thermal capacity is exceeded. The soft starter will trip in over temperature conditions, prevent-ing device failure.
The device pole temperature value can be monitored through the DIM or the communications network. This feature can be of use in determining an impending over temperature trip condition. Alarms can be implemented in the process monitoring system warning of an impending trip before a trip occurs, halting the process. Costly system shutdown can be avoided.
Phase Loss
Loss of a phase can cause a significant increase in the current drawn in the remaining two phases. Phase loss can lead to motor damage before an even-tual overload trip occurs. Phase loss is typically an indication of a failure in the electrical distribution system. The S811 will detect a phase loss and trip if any phase current drops below a preset value. The phase loss trip level is adjustable from 0% to 100% of the average of the other two phase levels with an adjustable trip delay of 0.1 to 60 seconds.
Phase Imbalance
Phase current or voltage imbalance can cause a significant increase in the current drawn in the remaining two phases. Phase imbalance can lead to motor damage before an eventual overload trip. Phase imbalance is typically an indication of a failure in the electrical distribution system or the motor. The S811 will detect both current and voltage phase imbalances and trip if any phase becomes imbal-anced as compared to the average of the other two phases.
The phase current imbalance trip level is adjustable from 0% to 100% of the average of the current in the other two phases with an adjustable trip delay of 0.1 to 60 seconds.
The phase voltage imbalance trip level is adjustable from 0% to 100% of the average of the voltage in the other two phases with an adjustable trip delay of 0.1 to 60 seconds.
Reset Mode
The S811 can be set up for automatic or manual reset on trip. The manual reset mode requires the operator to physically press the RESET button located on the soft starter. The over-load can be manually reset through the DIM or through the communica-tions network. The overload can also be electrically reset by energizing a 24V DC input on the control terminal block.
The automatic reset mode allows the soft starter to be automatically reset as soon as the trip condition is no longer present. With the automatic reset mode, after the fault is no longer present, the motor will be restarted as soon as a valid start signal is present.
Phase Reversal
The S811 can determine if the proper line phase sequence is present by default. The device will trip if the line phase sequence is something other than A-B-C. The S811 can be config-ured to operate under reversed phase conditions (A-C-B).
Shorted SCR Detection
The S811 monitors the operation of the power poles and will trip under a shorted SCR condition.
Open SCR Detection
The S811 monitors the operation of the power poles and will trip under an open SCR condition.
Low Current
Low current conditions can be a result of a loss of load or a failure in the mechanical system. The S811 has low current protection that will trip if the average RMS current falls below a pre-set value. The low current protection can be programmed as a percent of motor FLA from 0% to 100%.
Low Voltage
Low voltage conditions can result from disturbances in the electrical power distribution system. Low voltage conditions can cause a malfunction and damage to electrical equipment. The S811 has low voltage protection that will trip if the average RMS volt-age falls below a preset value. The low voltage protection can be pro-grammed as a percent of nominal voltage from 1% to 99% with a trip delay of 0.1 to 60 seconds.
High Voltage
High voltage conditions can result from disturbances in the electrical power distribution system. High volt-age conditions can cause malfunctions or failures of electrical equipment. The S811 has high voltage protection that will trip if the average RMS voltage is greater than a preset value. The high voltage protection can be pro-grammed as a percent of nominal voltage from 101% to 120% with a trip delay of 0.1 to 60 seconds.
April 2007
6
For more information visit:
www.eaton.com
CA03902004E
Reduced Voltage Motor StartersSolid-State Starters
Type S811, Intelligent Technologies
(IT.)
Soft Starters with DIM
Monitoring Capabilities
The S811 has an impressive array of system monitoring capabilities that allow users to access real time process and diagnostic data. This data can be viewed at the device with the DIM or through a communications network. Data over a communications network can provide valuable insight into the condition of the equipment and pro-cesses. Maintenance and production personnel can monitor critical opera-tional and maintenance data from a central control station that can be located far away from the production facility. Process data can be monitored to determine system anomalies that may indicate a need for preventive maintenance or an impeding failure. Adjustments made through the com-munications network can reduce costs by minimizing the time traveling to the location where the motor controls are located. When faults do occur, real time fault data can assist maintenance in troubleshooting and planning repair resources. Remote reset signals can be given to tripped devices without the need for manual intervention by main-tenance personnel.
Average Line Current
Provides the average of the three-phase RMS line currents in amps, accurate to within 2%. Current data can be used to indicate a need for maintenance. Increased currents in a fixed load application can indicate a reduction in system efficiencies and performance, signifying system maintenance is due.
Average Pole Current
Provides the average of the three-phase RMS pole currents in amps, accurate to within 2%. The pole current is the current through the soft starter. The line and pole current will be identical in in-line applications, and will differ in inside-the-delta applications.
Average line current as a % FLA
Provides the average RMS line current as a percentage of the S811 FLA setting.
Three-Phase Line CurrentsProvides three RMS phase line cur-rents in amps, accurate to within 2%. Imbalances or changes in the relative phase current to one another can indi-cate anomalies in the motor or electri-cal distribution system.
Three-Phase Pole CurrentsProvides three RMS phase pole cur-rents in amps, accurate to within 2%. The pole current is the current through the soft starter. The line and pole current will be identical in in-line applications, and will differ in inside-the-delta applications.
Three-Phase Line VoltagesProvides the individual RMS three-phase line voltages. Imbalances or changes in the relative phase voltage to one another can indicate anomalies in the motor or electrical distribution system. Voltage can be used to moni-tor electrical distribution system per-formance. Warnings, alarms and system actions to low or high voltage conditions can be implemented.
Percent Thermal MemoryProvides the real time calculated ther-mal memory value. The S811 calcu-lates thermal memory value. A 100% value represents the maximum safe temperature of the motor. When the thermal memory value reaches 100%, an overload trip will occur, removing power to the motor.
The thermal memory value can be of great use in determining an impending overload trip condition. Alarms can be implemented in the process monitor-ing system warning of an impending trip before a trip occurs, halting the process. Costly system downtime can be avoided.
DC Control VoltageMonitors level of the 24V DC control voltage. Fluctuations in control voltage can cause component malfunction and failure. System control voltage data can be used to implement warnings, alarms and system actions to low or high voltage conditions.
Pole TemperatureIncreases in pole temperature are caused by increases in ambient tem-perature, start/stop times and start duty cycles. Changes in pole tempera-tures represent a change in system operating conditions. Identifying unexpected operating conditions or changes can prompt maintenance and aid in process evaluation activities.
Device TemperatureAn increase in device temperature is a strong indication of an increase in ambient temperature. High ambient temperature operation can be identi-fied with the Device Temperature data. Ambient temperature increases can be due to loss of enclosure cooling fans or blocked venting. High ambient temperatures will reduce the life of all electrical equipment in the enclosure.
Start CountStart count data can be used to monitor system output, schedule preventative maintenance, identify system anomalies and identify changes in system operation.
Diagnostics
Fault QueueCurrent fault and a fault queue con-taining the last nine system faults can be read through the DIM or communi-cations network. Fault identification can minimize troubleshooting time and cost and prevent arc flash inci-dents. The fault queue can be remotely accessed through a communications network to assist in planning mainte-nance resources. 30 different faults can be identified by the S811.
Control StatusThe S811 provides data that repre-sents system conditions that can be read through the DIM or the communi-cations network. This data identifies the status of the system and the con-trol commands the system is request-ing of the S811. This can be used for advanced troubleshooting and system integration activities.
Breaker StatusThe S811 has provisions to read and display circuit breaker status. Cutler-Hammer communicating Cover Con-trol or other communicating protective device is required to take advantage of this feature.
April 2007
CA03902004E For more information visit: www.eaton.com
7Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Operation
Starting and Stopping ModesThe S811 has a variety of starting and stopping methods to provide superior performance in the most demanding applications. The motor can be started in either Voltage Ramp Start or Current Limit Start mode. Kick Start and Soft Stop are available within both starting modes.
Voltage Ramp StartProvides a voltage ramp to the motor resulting in a constant torque increase. The most commonly used form of soft start, this start mode allows you to set the initial torque value and the duration of the ramp to full voltage conditions. Bypass contactors close after ramp time.
■ Adjustable initial torque 0 – 85% of locked rotor torque.
■ Adjustable ramp time 0.5 – 180 seconds (can be extended with factory modification).
Current Limit StartLimits the maximum current available to the motor during the start phase. This mode of soft starting is used when it becomes necessary to limit the maxi-mum starting current due to long start times or to protect the motor. This start mode allows you to set the maximum starting current as a percentage of locked rotor current and the duration of the current limit. Bypass contactors close after current limit time.
■ Maximum current of 0 – 85% locked rotor current.
■ Adjustable ramp time 0.5 – 180 seconds (can be extended with factory modification).
Kick StartSelectable feature in both Voltage Ramp Start and Current Limit Start modes. Provides a current and torque “kick” for 0 to 2.0 seconds. This pro-vides greater initial current to develop additional torque to breakaway a high friction load.
■ 0 – 85% of locked rotor torque■ 0 – 2.0 seconds duration
Soft StopAllows for a controlled stopping of a load. Used when a stop-time that is greater than the coast-to-stop time is desired. Often used with high friction loads where a sudden stop may cause system or load damage.
■ Stop time = 0 – 60 seconds.
Figure 3. Starting Characteristics — Ramp Start
Figure 4. Starting Characteristics — Current Limit Start
Figure 5. Starting Characteristics — Kick Start
Figure 6. Starting Characteristics — Soft Stop
Run (FLA)
100%
Lock
ed R
oto
r To
rqu
e
Time (Seconds)
InitialTorque
Run
Max.Allowed
100%FLA
Cu
rren
t
Time (Seconds)
100%
Lock
ed R
oto
r To
rqu
e
Ramp
Time (Seconds)
KickStart
Run (FLA)
Ramp
Time (Seconds)
Run
April 2007
8
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Catalog Number Selection Table 2. S811 Open Soft Starters Catalog Numbering System
� Not available in U-Frame.� U-Frame 500 Amp unit does not have IEC Certification.
Edge and Level Sensing Control
Edge SensingEdge sensing is denoted with an “S” in the last character of the Catalog Number. Example: S801T30N3S.
Edge sensing requires +24V DC power be momentarily applied to pin 1 (with terminal P at +24V DC) to initiate a start under all conditions. After a stop or fault occurs, the +24V DC must be removed, then reapplied to pin 1 before another start can occur. This control configuration should be used when restarting of the motor after a fault or stop must be supervised man-ually or as a part of a control scheme. The cycling of +24V DC power to ter-minal 1 before starting is required regardless of the position of the auto reset switch on the CIM.
Level Sensing Level sensing is denoted with a “B” in the last character of the Catalog Number. Example: S801T30N3B.
Level sensing will enable a motor to restart after a fault is cleared without cycling +24V DC power to terminal 1 as long as:
■ Terminal P is supplied with +24V DC (to start from Terminal Block, Input #3 must also be enabled),
■ The auto reset switch on the CIM is set to enabled,
■ All faults have been reset.
This control configuration should be used where it is desirable to restart a motor after a fault without additional manual or automatic control. An example of this condition would be on a remote pumping station where it is desirable to automatically restart a pump after a power outage without operator intervention.
If the auto reset feature is used, CAUTION must be exercised to assure that any restart occurs in a safe manner.
S 8 1 1 T 3 0 N 3 S
Ampacity Rating
37 = 37 amps66 = 66 amps10 = 105 amps13 = 135 amps18 = 180 amps24 = 240 amps30 = 304 amps
36 = 360 amps42 = 420 amps50 = 500 amps �65 = 650 amps72 = 720 amps85 = 850 amps10 = 1000 amps
Frame Size
N = 65 mmR = 110 mmT = 200 mmU = 200 mmV = 290 mm
811 = Non-combination Soft Starter
N = No OptionsP = Pump ControlV = 690V Option
(Frame T18 through V85) �
3 = 3-Pole Device
S = Standard Soft Starter (Configurable for Edge or Level Control)
D = Inside-the-DeltaL = Extended Ramp StartW = Without DIM
S = IT. Soft Starter
April 2007
CA03902004E For more information visit: www.eaton.com
9Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Product Selection Motor applications and customer needs come in many different varieties. With the standard and severe duty rating tables, we have attempted to provide guidelines on what the IT. Soft Starter is capable of. If the application falls
under these categories, you can use these charts. For other applications, or when a question arises, consult with your local Eaton Representative or call our Technical Resource Center.
Standard DutyTable 3. Standard Duty Ratings
Table 4. Product Selection — 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.
Starting Method Ramp Current %of FLA
Ramp TimeSeconds
Starts perHour
AmbientTemperature
vs. Soft Startvs. Full Voltagevs. Wye-Deltavs. 80% RVATvs. 65% RVATvs. 50% RVAT
300%500%350%480%390%300%
30 sec.10 sec.20 sec.20 sec.20 sec.20 sec.
333234
50°C50°C50°C50°C50°C50°C
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
3766
1018.5
18.530
18.537
1020
1015
1020
1020
2550
2040
3060
3050
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
105135
3040
5563
5980
3040
2530
4050
3040
75100
6075
100125
75100
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
180240304
517590
90110160
110147185
6075
100
506075
6075
100
6075
100
150200250
125150200
150200300
150200250
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
360420500
110129150
185220257
220257300
125150150
100125150
150175200
125150150
300350400
250300350
350450500
300350450
S811U36N3SS811U42N3SS811U50N3S �
7,880.8,870.9,980.
Frame Size V
360420500650
110129150200
185220257355
220257300425
125150150250
100125150200
150175200250
125150150200
300350400500
250300350450
350450500600
300350450500
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
720850
1000
220257277
400475525
45050050
———
———
300350400
250300350
600700800
500600700
700900900
600700800
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
10
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Table 5. Product Selection — 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.
Table 6. Product Selection — 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
3463
915
1530
18.533
1020
7-1/215
1020
1020
2540
2040
3060
2550
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
96120
2533
4563
5563
3040
2530
3040
3040
7575
6075
75100
75100
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
150215278
456380
80110147
90132160
506075
406075
5075
100
506075
100150200
100150200
150200250
125150250
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
320380460
90110140
160200250
185220280
100125150
75100125
125150150
100125150
250300350
200250300
300350450
250300400
S811U36N3SS811U42N3SS811U50N3S �
7,880.8,870.9,980.
Frame Size V
320380460610
90110140185
160200250315
185220280375
100125150250
75100125150
125150150200
100125150200
250300350500
200250300450
300350450600
250300400500
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
680810890
200250290
375450510
445500560
———
200——
250300400
200300350
600700700
500600600
700900900
600700700
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
3463
915
1530
18.533
1020
7-1/215
1020
1020
2540
2040
3060
2550
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
96120
2533
4563
5563
3040
2530
3040
3040
7575
6075
75100
75100
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
150215278
456380
80110147
90132160
506075
406075
5075
100
506075
100150200
100150200
150200250
125150250
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
320380460
90110140
160200250
185220280
100125150
75100125
125150150
100125150
250300350
200250300
300350450
250300400
S811U36N3SS811U42N3SS811U50N3S �
7,880.8,870.9,980.
Frame Size V
320380460610
90110140185
160200250315
185220280375
100125150250
75100125150
125150150200
100125150200
250300350500
200250300450
300350450600
250300400500
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
680830960
200257302
375450510
445500540
———
200——
250300350
200300300
600700800
500600700
700900900
600700800
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
CA03902004E For more information visit: www.eaton.com
11Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Table 7. Product Selection — 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.� 500A rating does not have IEC certification.
Table 8. Product Selection — 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
2142
5.511
1018.5
1122
510
510
515
510
1530
1025
1540
1530
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
6080
1522
3040
3345
1525
1520
2030
1525
4060
4050
5075
5060
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
115150192
334555
5980
100
6390
110
305060
304050
405060
305060
75100150
75100125
100150200
100125150
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
280340380
80110110
150180200
160200220
75100125
75100100
100125150
75100125
200250300
200200250
250350350
250300300
S811U36N3SS811U42N3SS811U50N3S �
7,880.8,870.9,980.
Frame Size V
280340380420
80110110129
150180200220
160200220257
75100125150
75100100125
100125150150
75100125150
200250300350
200200250300
250350350450
250300300350
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
480590650
147180205
257315370
295375415
150200250
150150200
200200250
150200200
400500500
350400450
500600600
450500500
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
2949
7.512.5
12.522
1525
7-1/215
7-1/210
1015
7-1/215
2030
1530
2540
2040
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
7394
18.525
3745
4055
2030
2025
2530
2030
5060
4060
6075
6075
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
155219280
456380
80110150
90132160
506075
406075
6075
100
506075
100150200
100150200
150200250
125150250
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
345405
100110
185200
200250
100125
100100
125150
100125
250300
200250
350400
300350
S811U36N3SS811U42N3S
7,880.8,870.
Frame Size V
345405465530
100110140160
185200250280
200250280335
100125150150
100100125150
125150150200
100125150150
250300350450
200250300350
350400450500
300350400450
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
590651754
180200220
315355400
375425465
200——
150——
———
200——
500600600
400450500
600700800
500600700
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
12
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Table 9. Product Selection — 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
2140
5.511
1018.5
12.522
510
510
510
510
1530
1025
1530
1530
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
5575
1522
2537
3045
1520
1520
2025
1520
4050
3050
5060
4060
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
151215264
456380
80110140
90132160
506075
406075
5075
100
506075
100150200
100150150
150200250
125150200
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
300340
90100
160180
185200
100100
75100
100125
100100
200250
200200
300350
250300
S811U36N3SS811U42N3S
7,880.8,870.
Frame Size V
300340380420
90100110129
160180200220
185200220257
100100125150
75100100125
100125150150
100100125150
200250300350
200200250300
300350350450
250300300350
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
460500560
140150160
250257277
280300325
150150200
125150150
150200250
150150200
350400500
300350400
450500600
400450500
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
CA03902004E For more information visit: www.eaton.com
13Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Severe DutyTable 10. Severe Duty Ratings
Table 11. Product Selection — > 30 Second Ramp, > 4 Starts per Hour or >300% Current Limit
� For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Severe Duty Ratings are defined as any combination of parameters that exceed the Standard Duty Ratings where the ramp time is over 30 seconds, the number of starts per hour exceeds 4, or the current limit set is over 300%. Example: 35-Second Ramp, 5 Starts per Hour, 350% Current Limit @ 40°C Ambient.
Starting Method Ramp Current %of FLA
Ramp TimeSeconds
Starts perHour
Ambient Temperature
vs. Soft Startvs. Full Voltagevs. Wye-Deltavs. 80% RVATvs. 65% RVATvs. 50% RVAT
450%500%350%480%390%300%
30 sec.10 sec.65 sec.25 sec.40 sec.60 sec.
4103444
50°C50°C50°C50°C50°C50°C
Max.Current
Three-Phase Motors CatalogNumber
PriceU.S. $
kW Rating (50 Hz) hp Rating (60 Hz)
230V 380 – 400V
440V 200V 230V 460V 575 – 690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N
2242
5.511
1018.5
1122
510
510
7-1/215
510
1530
1025
2040
1530
S811N37N3SS811N66N3S
1,960.3,010.
Frame Size R
6580
1522
3040
3345
1525
1520
2030
1525
5060
4050
5075
5060
S811R10N3SS811R13N3S
4,540.5,640.
Frame Size T
115150192
334555
5980
100
6390
110
305060
304050
405075
305060
75100150
75100125
100150200
100125150
S811T18N3SS811T24N3SS811T30N3S
5,780.6,150.6,540.
Frame Size U
240305
7590
110160
147185
75100
6075
75100
75100
200250
150200
200300
200250
S811U36N3SS811U42N3S
7,880.8,870.
Frame Size V
240305365420
7590
110129
110160185220
147185220257
75100125150
6075
100125
75100150150
75100125150
200250300350
150200250300
200300350450
200250300350
S811V36N3SS811V42N3SS811V50N3SS811V65N3S
7,610.8,570.9,640.
10,850.
480525575
147160172
257280303
295335370
150150200
150150150
200200250
150150200
400450500
350350450
500500600
450450500
S811V72N3SS811V85N3SS811V10N3S �
12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
14
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Inside-the-Delta Standard Duty Ratings
Table 12. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C Ambient
� 15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 865A Inside-the-Delta Starter.
� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Table 13. 25 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40°C Ambient
� 15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 796A Inside-the-Delta Starter.
� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N65
1141018.5
18.530
18.537
1530
1525
1530
1530
4075
3060
50100
5075
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R182234
3040
5563
5980
5060
4050
6075
5060
125150
100125
150200
125150
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T311415526
517590
90110160
110147185
100125150
75100125
100125150
100125150
250300400
200250300
250300400
250300400
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U623727865
110129150
185220257
220257300
200250250
150200250
250300300
200250250
450550600
400450550
550700750
450550700
S811U36N3DS811U42N3DS811U50N3D ��
7,880.8,870.9,980.
Frame Size V623727865
112512461471—
110129150200———
185220257355———
220257300425———
200250250400———
150200250300———
250300300400———
200250250300———
450550600750———
400450550700———
550700750900———
450550700750———
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �
7,610.8,570.9,640.
10,850.12,470.15,100.25,200.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N58
1089
151530
18.533
1530
1025
1530
1530
4060
3060
50100
4075
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R164206
2533
4563
5563
5060
4050
5060
5050
125125
100125
125150
125150
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T257365477
456380
80110147
90132160
75100125
60100125
75125150
60100125
150250300
150250300
250300400
200250400
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U554646796
90110140
160200250
185220280
150200250
125150200
200250250
150200250
400500550
300400500
450550700
400450600
S811U36N3DS811U42N3DS811U50N3D ��
7,880.8,870.9,980.
Frame Size V554646796
105511761358—
90110140185200——
160200250315375——
185220280375445——
150200250400———
125150200250300——
200250250300400——
150200250300300——
400500550800900——
300400500700800——
450550700900900——
400450600750900——
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �
7,610.8,570.9,640.
10,850.12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
CA03902004E For more information visit: www.eaton.com
15Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Inside-the-Delta Standard Duty Ratings
Table 14. 15 Second Ramp, 4 Starts per Hour, 300% Current Limit @ 50°C Ambient
� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Table 15. 50 Second Ramp, 2 Starts per Hour, 300% Current Limit @ 50°C Ambient
� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N58
1089
151530
18.533
1530
1025
1530
1530
4060
3060
50100
4075
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R164206
2533
4563
5563
5060
4050
5060
5060
125125
100125
125150
125150
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T257365477
456380
80110147
90132160
75100125
60100125
75125150
75100125
150250300
150250300
250300400
200250400
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U554646796
90110140
160200250
185220280
150200250
125150200
200250250
150200250
400450550
300400450
450550700
400450600
S811U36N3DS811U42N3DS811U50N3D �
7,880.8,870.9,980.
Frame Size V554646796
105511761358—
90110140185200257—
160200250315375450—
185220280375445500—
150200250400———
125150200250———
200250250300———
150200250300———
400450550750———
300400450700———
450550700900———
400450600750———
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �
7,610.8,570.9,640.
10,850.12,470.15,100.25,200.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N3673
5.511
1018.5
1122
7-1/215
7-1/215
7-1/225
7-1/215
2550
1540
2560
2550
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R103138
1522
3040
3345
2540
2530
3050
2540
60100
6075
75125
75100
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T199257324
334555
5980
100
6390
110
5075
100
506075
6075
100
5075
100
125150250
125150200
150250300
150200250
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U485580646
80100110
150180200
160200220
125150200
125150150
150200250
125150200
300400450
300300400
400550550
400450450
S811U36N3DS811U42N3DS811U50N3D �
7,880.8,870.9,980.
Frame Size V485580646727816
1021—
80100110129147180—
150180200220257315—
160200220257295375—
125150200250250300—
125150150200250250—
150200250250300300—
125150200250250300—
300400450550600750—
300300400500550600—
400550550700750900—
400450450550700750—
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �
7,610.8,570.9,640.
10,850.12,470.15,100.25,200.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
16
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Inside-the-Delta Standard Duty Ratings
Table 16. 15 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C Ambient
� U-Frame 500 Amp unit does not have IEC Certification.
Table 17. 30 Second Ramp, 4 Starts per Hour, 450% Current Limit @ 40°C Ambient
� U-Frame 500 Amp unit does not have IEC Certification.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N4783
7.512.5
12.522
1525
1025
1015
1525
1025
3050
2550
4060
3060
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R126162
18.525
3745
4055
3050
3040
4050
3050
75100
60100
100125
100125
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T266379485
456380
80110150
90132160
75100125
60100125
100125150
75100125
150250300
150250300
250300400
200250400
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U580695798
100110140
185200250
200250280
150200250
150150200
200250250
150200250
400450550
300400450
550600700
450550600
S811U36N3DS811U42N3DS811U50N3D �
7,880.8,870.9,980.
Frame Size V580695798908
10211125
100110140160——
185200250280——
200250280335——
150200250250——
150150200250——
200250250300——
150200250250——
400450550700——
300400450550——
550600700750——
450550600700——
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3D
7,610.8,570.9,640.
10,850.12,470.15,100.
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N3669
5.511
1018.5
12.522
7-1/215
7-1/215
7-1/215
7-1/215
2550
1540
2550
2550
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R96
1301522
2537
3045
2530
2530
3040
2530
6075
5075
75100
60100
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T257365448
456380
80110140
90132160
75100125
60100125
75125150
75100125
150250300
150250250
250300400
200250300
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U503580646
90100110
160180200
185200220
150150200
125150150
150200250
150150200
300400450
300300400
450550550
400450450
S811U36N3DS811U42N3DS811U50N3D �
7,880.8,870.9,980.
Frame Size V503580646727796865
90100110129——
160180200220——
185200220257——
150150200250——
125150150200——
150200250250——
150150200250——
300400450550——
300300400450——
450550550700——
400450450550——
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3D
7,610.8,570.9,640.
10,850.12,470.15,100.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
CA03902004E For more information visit: www.eaton.com
17Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Inside-the-Delta Severe Duty Ratings Severe Duty Ratings are defined as any combination of parameters that exceed the Standard Duty Ratings where the ramp time is over 30 seconds, the num-ber of starts per hour exceeds 4, or the current limit set is over 300%.
Example: 35-Second Ramp, 5 Starts per Hour 350% Current Limit @ 40°C Ambient.
Table 18. Severe Duty Inside-the-Delta Ratings
� U-Frame 500 Amp unit does not have IEC Certification. � For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Typical Power Wiring Diagrams
Figure 7. Line Connected Soft Starter Power Wiring Diagram
Max.Continuous Motor Line Current
Three-Phase Motor CatalogNumber
PriceU.S. $kW Rating (50 Hertz) hp Rating (60 Hertz)
230 380 – 400 440 200V 230V 460V 575V
Volt Volt Volt 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Frame Size N3973
5.511
1018.5
1122
7-1/215
7-1/215
1025
7-1/215
2550
1540
3060
2550
S811N37N3DS811N66N3D
1,960.3,010.
Frame Size R111138
1522
3040
3345
2540
2530
3050
2540
75100
6075
75120
75100
S811R10N3DS811R13N3D
4,540.5,640.
Frame Size T199257324
334555
5980
100
6390
110
5075
100
506075
6075
100
5075
100
125150250
125150200
150250300
150200250
S811T18N3DS811T24N3DS811T30N3D
5,780.6,150.6,540.
Frame Size U415526623
7590
110
110160185
147185220
125150200
100120150
125150250
125150200
300400450
250300400
300450550
300400450
S811U36N3DS811U42N3DS811U50N3D �
7,880.8,870.9,980.
Frame Size V415526623727816908—
7590
110129147160—
110160185220257280—
147185220257295335—
125150200250250250—
100120150200250250—
125150250250300300—
125150200250250250—
300400450550600700—
250300400450550550—
300450550700750750—
300400450550700700—
S811V36N3DS811V42N3DS811V50N3DS811V65N3DS811V72N3DS811V85N3DS811V10N3D �
7,610.8,570.9,640.
10,850.12,470.15,100.25,200.
1 L1 3 L2
S811
5 L3
2 T1 4 T2 6 T3
M3˜
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
18
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Figure 8. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a6-Lead Motor
Figure 9. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a12-Lead Low Voltage Motor
Figure 10. Inside-the-Delta Connected Soft Starter Power Wiring Diagram for a12-Lead High Voltage Motor
L1S L2SSupply
L3S
L31L1
3L2
5L3
T5 T4 T6
T3
T3
T3
T6
T4
T1T1
T2
T2
T2
T1
2T1
4T2
6T3
S811
T5
L1
L1
Motor
L3
L2L2
L1S L2SSupply
L3S
L3
L1
1L1
3L2
5L3
T11T5
T11T10T4
T12T6
T3T9
T3
T5
T3
T6T10
T7
T4
T1
T1
T12
T9
T2T8
T2T2
T1T7
2T1
4T2
6T3
T8
L1
Motor
L3
L2L2
12-LeadLow Voltage
S811
L1S L2SSupply 12-Lead
High VoltageL3S
L3
L1
1L1
3L2
5L3
T11
T11
T10 T12
T3
T3
T3
T6T10
T7T4
T1T1
T12
T9
T2
T2
T2
T1
2T1
4T2
6T3
T8T5
T5T8
T6T9
L1
T7T4
Motor
L3
L2L2
S811
April 2007
CA03902004E For more information visit: www.eaton.com
19Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Options Extended Ramp For a longer ramp acceleration time of .5 – 360 seconds, change the last digit in the Catalog Number from Page 9 to L. Table 19. Extended Ramp Option
� U-Frame 500 Amp unit does not have IEC Certification.
Extended Ramp and 690V Option690V ratings are available on the T and V Frames by changing the 8th digit in the Catalog Number to V.Table 20. 690V Option
Pump ControlFor pump control option, change the 8th digit in the Catalog Number to P.Table 21. Pump Control Option
� U-Frame 500 Amp unit does not have IEC Certification.
FrameSize
Max.Current
CatalogNumber
PriceU.S. $
N 3766
S811N37N3LS811N66N3L
2,360.3,415.
R 105135
S811R10N3LS811R13N3L
4,945.5,640.
T 180240304
S811T18N3LS811T24N3LS811T30N3L
6,190.6,570.6,940.
U 360420500
S811U36N3LS811U42N3LS811U50N3L �
8,320.9,290.
10,400.V 360
420500650
S811V36N3LS811V42N3LS811V50N3LS811V65N3L
8,030.8,970.
10,040.11,260.
720850
1000
S811V72N3LS811V85N3LS811V10N3L
12,870.15,490.24,710.
Frame Size
Max.Current
CatalogNumber
PriceU.S. $
T 180240304
S811T18V3LS811T24V3LS811T30V3L
6,930.7,310.7,450.
V 360420500
S811V36V3LS811V42V3LS811V50V3L
8,530.9,490.
10,560.650720850
S811V65V3LS811V72V3LS811V85V3L
11,770.13,380.16,010.
FrameSize
Max.Current
CatalogNumber
PriceU.S. $
N 3766
S811N37P3SS811N66P3S
3,170.4,230.
R 105135
S811R10P3SS811R13P3S
5,750.6,660.
T 180240304
S811T18P3SS811T24P3SS811T30P3S
7,010.7,360.7,740.
U 360420500
S811U36P3SS811U42P3SS811U50P3S �
9,160.10,150.11,250.
V 360420500650
S811V36P3SS811V42P3SS811V50P3SS811V65P3S
8,850.9,800.
10,860.12,090.
720850
1000
S811V72P3SS811V85P3SS811V10P3S
13,690.16,330.25,490.
Accessories
Surge SuppressorsThe surge suppressor can mount on either the line or load side of the IT. Soft Starter. It is designed to clip the line voltage (or load side induced voltage).
Table 22. Surge Suppressors
� T-Frame only.
Lug Kits The 200 mm and 290 mm soft starters do not include lugs.
The 200 mm and 290 mm soft starters each have different lug options based on your wiring needs. Each lug kit con-tains three lugs which can be mounted on either the load or line side.
Table 23. Lug Kits
� The EML33 does not have a CSA Listing.
Lug Cover Kits Replacement covers for the T and V frame are available in case of damage to the existing covers.
Table 24. Lug Cover Kits
Description CatalogNumber
PriceU.S. $
600V MOV for 65 mm and 110 mm units
EMS38 178.
600V MOV for 200 mm and 290 mm units
EMS39 193.
690V MOV for 200 mm � and 290 mm units
EMS41 220.
Surge Suppressor
Surge SuppressorMounted on a 200 mm Device
Lug Kits — EML23
FrameSize
FrameDesignation
Description CatalogNumber
PriceU.S. $
200 mm SSRV
T, U 2 cable connections, 4 AWG to 1/0 cable1 cable connection, 4/0 to 500 MCM cable2 cable connections, 4/0 to 500 MCM cable1 cable connection, 2/0 to 300 MCM cable2 cable connections, 2/0 to 300 MCM cable
EML22EML23EML24EML25EML26
175.197.249.175.222.
290 mmSSRV
V 2 cable connections, 4/0 to 500 MCM cable4 cable connections, 4/0 to 500 MCM cable6 cable connections, 4/0 to 500 MCM cable4 cable connections, 2/0 to 300 MCM cable
EML28EML30EML32EML33 �
402.403.585.408.
Description CatalogNumber
PriceU.S.$
Lug Cover T, U Frame EML27 79.
Lug Cover V Frame EML34 98.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
20
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Digital Interface ModuleThe Digital Interface Module (DIM) is available as a replacement part.
Table 25. DIM
Control Wire ConnectorTable 26. Control Wire Connector
User Manual A comprehensive user manual is available and can be downloaded free of charge from www.eaton.com by performing a document search for MN03902002E.
Mounting PlatesThe Mounting Plates are designed to help make it easy to install or retrofit the soft starter into enclosures and MCCs. The soft starter can be mounted onto the plate prior to installation. The mounting plate is designed with tear drop mounting holes for easier installation.
Table 27. Mounting Plates
Adapter PlatesThe Adapter Plate allows customers to retrofit a V-Frame 290 mm Soft Starter with the U-Frame 200 mm Soft Starter.
Table 28. Adapter Plates
� For more information see Pub. 51719.
Vibration PlatesThe Vibration Plates allow the soft starter to be applied in high shock and vibration applications. The vibration plate allows vibration up to 5g and shock in up to 40g. The soft starter is mounted onto the vibration plate prior to installation in the panel.
Table 29. Vibration Plates
Power Supplies24V DC Power Supply which can be used with the S811 SSRV or as a stand- alone device.
Table 30. Power Supplies
DIN Rail Power Supply Mounting Kit (35 mm) Table 31. DIN Rail Mounting Kit
Standards and Certifications ■ IEC 60947-4-2■ EN 60947-4-2■ UL Listed (NMFT) – Frame N37
to V85■ UL Recognized (NMFT2) – Frame V10■ CE Marked■ CSA Certified (3211 06)■ CSA Elevator (2411 01)
Instructional Leaflets■ Instruction Manual: MN03902002E■ Outline Drawings:
❑ 65 mm, N-Frame: 10-8574❑ 110 mm, R-Frame: 10-8575❑ 200 mm, T-Frame: 10-8576❑ 200 mm, U-Frame: 10-8857❑ 290 mm, V-Frame: 10-8577
Description CatalogNumber
PriceU.S. $
Blank Cover (Filler) EMA68 58.50
DIM EMA91 332.00
Panel Mounting Kit —3 ft. Cable5 ft. Cable8 ft. Cable
10 ft. Cable
EMA69AEMA69BEMA69CEMA69D
196.00221.00245.00271.00
Description CatalogNumber
PriceU.S.$
12 pin, 5 mm pitchConnector forControl Wiring
EMA75L 16.20
Description CatalogNumber
PriceU.S. $
Mounting Plate N Frame EMM13N 61.50
Mounting Plate R Frame EMM13R 85.00
Mounting Plate T, U Frame
EMM13T 95.00
Mounting Plate V Frame EMM13V 122.00
Fan/Hood Accessory EMM18 158.00
Description CatalogNumber
PriceU.S. $
Adapter Plates � EMM13U 220.00
Description CatalogNumber
PriceU.S. $
Vibration Plate N Frame EMM14N 158.00
Vibration Plate R Frame EMM14R 170.00
Vibration Plate T, U Frame
EMM14T 196.00
Vibration Plate V Frame EMM14V 228.00
Description CatalogNumber
PriceU.S. $
115V AC Input24V DC Output
PSS55A 262.00
230V AC Input24V DC Output
PSS55B 262.00
380 – 480V AC Input24V DC Output
PSS55C 312.00
Description CatalogNumber
PriceU.S. $
DIN Rail Mounting Kit (35 mm)
PSSDIN 25.00
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . 1CD1
April 2007
CA03902004E For more information visit: www.eaton.com
21Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Technical Data and SpecificationsTable 32. Specifications— IT. Soft Starter
� U-Frame 500 Amp unit does not have IEC Certification.� UR Recognized Product.
Soft Starter (Partial Catalog Number)
S811N37
S811N66
S811R10
S811R13
S811T18
S811T24
S811T30
S811U36
S811U42
S811U50 �
S811V36
S811V42
S811V50
S811V65
S811V72
S811V85
S811V10 �
Max. Current Capacity 37 66 105 135 180 240 304 360 420 500 360 420 500 650 720 850 1000FLA Range 11 –
3720 – 66
32 – 105
42 – 135
56 – 180
75 – 240
95 – 304
112 – 360
131 – 420
156 – 500
112 – 360
131 – 420
156 – 500
203 – 650
225 – 720
265 – 580
320 – 1000
DimensionsWidth in Inches (mm) 2.66 (67.6) 4.38 (111.3) 7.67 (194.8) 7.73 (196.3) 11.05 (280.6)Height in Inches (mm) 7.38
(187.4)7.92 (201.2) 12.71 (322.9) 12.72 (323.1) 16.57 (420.8)
Depth in Inches (mm) 6.47 (164.4)
6.66 (169.2) 6.39 (162.4) 7.08 (179.9) 7.35 (186.6)
Weight in lbs. (kg) 5.8 (2.6) 10.5 (4.8) 48 (21.8) with lugs41 (18.6) without
lugs
48 (21.8) with lugs41 (18.6) without lugs
103 (46.8) with lugs91 (41.4) without lugs
General InformationBypass Mechanical Lifespan
10M
Insulating Voltage Ui 660VRamp Time Range .5 – 180 Seconds (.5 – 360 Seconds Extended Ramp)Resistance to Vibration 3gResistance to Shock 15g
Electrical InformationOperating Voltage 200 – 600VOperating Frequency 47 – 63 HzOverload Setting 30 – 100%Trip Class 5, 10, 20, & 30
Cabling Capacity (IEC 947)Number of Conductors 1 1 1 or 2 1 or 2 2, 4 or 6Wire Sizes 14 – 2 14 – 4/0 4 AWG to 500 MCM 4 AWG to 500 MCM 2/0 to 500 MCM Type of Connectors Box Lug Add-On Lug Kit
Control Wiring (12-Pin)Wire Sizes in AWG 22 – 14Number of Conductors (Stranded)
2 (or one AWG 12)
Torque Requirements in lb-in
3.5
Solid, Stranded or Flexible Max. Size in mm2
3.31
Control Power RequirementsVoltage Range (24V ± 10%) 21.6 – 26.4Steady State Current Amps
1.0 1.0 1.0 1.0 1.4
Inrush Current Amps 10 10 10 10 10Ripple 1%
Relays (1) Class A and CVoltage AC — maximum 240Voltage DC — maximum 120Amps — maximum 3
EnvironmentTemperature — Operating -30 – 50°C (No derating) Consult factory for operation > 50˚ CTemperature — Storage -50 – 70°CAltitude <2000 Meters — Consult factory for operation > 2000mHumidity <95% Non-condensingOperating Position AnyPollution degree IEC947-1 3Impulse withstand Voltage IEC947-4-1
6000V
April 2007
22
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Dimensions
Figure 11. N-Frame (65 mm) S811 Approximate Dimensions in Inches (mm)
Figure 12. R-Frame (110 mm) S811 Approximate Dimensions in Inches (mm)
6.87(174.5)
1.97(50.0)
.22 (5.5)Typ.
4 Places
2.66(67.6)
3.46(88.0)
5.35(135.9)
6.47(164.4)
7.38(187.4)
3.49(88.5)
5.53(140.5)
6.66(169.2)
7.44(189.0)
3.54(90.0)
4.38(111.3)
7.92(201.2)
.27 (6.8)Typ.
4 Places
April 2007
CA03902004E For more information visit: www.eaton.com
23Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Figure 13. T-Frame (200 mm) S811 Approximate Dimensions in Inches (mm)
Figure 14. U-Frame (200 mm) S811 Approximate Dimensions in Inches (mm)
5.40(137.2)
6.39(162.4)
7.67(194.8)
11.77(299.0)Slots
12.71(322.9)
2.95(75.0)Slots
.28(7.1)
Slots Typ.6 Places
5.91 (150.0)Slots
11.77 (299.0)Mounting
5.20 (132.0)Mounting
Mounting Slotsfor M6 (1/4) Screws(Up to 6 Quantity)
.47(11.9)
7.08(179.9)
12.72(323.1)
7.73(196.3)
5.20 (132.0)Pole Centers
C L
C L
April 2007
24
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersSolid-State StartersType S811, Intelligent Technologies (IT.) Soft Starters with DIM
Figure 15. V-Frame (290 mm) S811 Approximate Dimensions in Inches (mm)
3.74(95.0)
.26 (6.5) Dia.Typ.
4 Places
7.35(186.6)
15.16(385.0)Slots
15.63(397.0)
MountingHoles
16.57(420.8)
9.84(250.0)
11.05 (280.6).27 (6.8)Typ.
4 Places
April 2007
CA03902004E For more information visit: www.eaton.com
25Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview
ContentsDescription Page
IT. Solid-State Soft Starters — Enclosed
Product Family Overview . . . . . . . . . . . . . . . 25
Cover Control . . . . . . . . . . . . . 26
Catalog NumberSelection . . . . . . . . . . . . . . . 27
Non-combination
Product Selection. . . . . . . . . . 28
Combination with Fusible Disconnect
Product Selection. . . . . . . . . . 29
Combination with Breaker
Product Selection. . . . . . . . . . 30
Dimensions . . . . . . . . . . . . . . . . . 31
Product DescriptionEaton’s revolutionary design for soft starters is shown in the S752, S801 and S811 soft starter products which are members of the Cutler-Hammer® Intelligent Technologies (IT.) family of products. These Reduced Voltage Soft Starters are the most compact, multi-functional, easy-to-install products on the market. Their superiority begins with the control package, which fea-tures 24V DC control, onboard Digital Signal Processor (DSP), and use of a low impedance run contactor, all of which contribute to the IT. Soft Starter’s safety, advanced functionality and compact size.
Designed to control acceleration and deceleration of three-phase motors, products are available from .25 to 1000 amps and are suitable for mounting in a variety of enclosures including Type 1, 12, 3R, 4, 4X and 7/9.
■ Built-in overload protection❑ Adjustable trip class 5, 10, 20, 30❑ 30 – 100% FLA adjustment❑ Selectable phase loss protection
■ Selectable current limit or ramp start
■ Adjustable ramp times❑ 0 – 180 seconds standard❑ Extended ramps available
■ Adjustable torque control■ Adjustable kick start control■ Soft Stop control
❑ 0 – 60 seconds standard❑ Extended times available
■ Built-in low impedance contactor■ Six SCR Control in all units■ Selectable phase reversal protection■ Digital Interface Module
Features and Benefits■ Mechanical stress on system
❑ Reduced wear on belts, gears, chains, clutches, shafts and bear-ings. You can get up to 2 – 6 times the life on standard belts by switching to a soft starter.
❑ Elimination of water-hammer in pumping applications extends component life and helps limit leakage in system.
❑ Lower shock to product on con-veyor lines and material handling gear.
❑ Able to catch motors and fans on the fly and control their acceleration.
■ Electrical system improvements❑ Limits the peak inrush current as
required by many local codes. ❑ Helps to eliminate sags on the
plant electrical grid when starting large loads, thus avoiding brown-out conditions.
■ 24V DC advantages❑ Offers improved personnel safety
by eliminating the need for 120V AC in the enclosure.
❑ Soft Starter able to ride through 50% voltage conditions indefi-nitely due to 24V DC power supply and 0% for up to 100 mS.
■ 690V Option available on 180A ratings and larger
Digital Interface ModuleThe S811 has an easy to use Digital Interface Module (DIM) that allows the user to configure the device and to read system parameters. The DIM includes an LCD display and keypad to scroll through the various menus. The DIM allows the user to modify control parameters, enable or disable protec-tions, set communication variables, monitor system parameters such as line voltages and currents, and access the fault queue.
Digital Interface Module (DIM)
The DIM can be removed from the S811 and remote mounted. Kits are available to door mount the DIM, enabling users to safely configure, commission, monitor and trouble-shoot the system at the electrical panel without opening the enclosure door.
Enclosed 40 hp Soft StarterESC
ONLN SS OXFDO1 H STOP
Monitoring
PREV NEXT ENTER
April 2007
26
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview
Standards and Certifications■ UL Listed■ IEC 947-4-2■ EN 60947.2 (for motor controller)■ cUL (indicates appropriate CSA
Standard investigation)■ ABS Type Approved
Options
Pump Control Option■ Designed to reduce “water-
hammer” during start-up and stopping sequences
■ Stop ramp extended to 120 seconds to help control larger motors and systems with long piping runs
LCD Display■ 2 line x 20 character LED back-lit
LCD display■ NEMA 4 rated■ Parameters
❑ Voltage L-L (AB, BC, AC) ❑ Phase Current❑ Average Current❑ Overload Current Setting❑ Pole Temperature❑ Relay Trip Class❑ Thermal Pile❑ Average Line Current as % of FLA❑ DC Control Voltage❑ Start Count❑ Fault History
■ English or Spanish version
Table 33. Options Description Modification
Code
Pump Control Option P42
LCD Display K5
Extended Ramp R1
Cover Control
Flange Control KitsFor on-the-job conversion of Type 1, 3R, 4, 4X and 12 enclosed starters. Knock-outs are provided on the Type 1 flange. Type 3R, 4, 4X and 12 have prepunched holes with removable hole plugs.
Factory Installed Pilot DevicesTo order factory installed pilot devices, change the 9th character of the Catalog Number to the alpha shown in the table below. Example: to order an ECS90J4CAA with START/STOP pushbuttons and a red pilot light, change the A to a C, i.e. ECS90J4CCA.
Table 34. Non-reversing Pilot Devices
� Add Code Letter from the table below to Catalog Number for voltage — Kits only. Example: C400T9B.
Description Factory InstalledFlange Control
Field Installation Kits
Position9 Alpha
AdderU.S. $
CatalogNumber
PriceU.S. $
No Cover Mounted Pilot DevicesSTART/STOP Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights
ABCD
—224.00408.00592.00
—C400T1——
—99.50
——
ON/OFF Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights
EFG
224.00408.00592.00
C400T2——
99.50——
HAND/OFF/AUTO Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights
HJK
201.00385.00569.00
C400T12——
99.50——
START PushbuttonON PushbuttonOFF PushbuttonRed RUN Pilot LightGreen OFFRed RUN/Green OFF Pilot Lights
LMNPQR
224.00224.00224.00224.00224.00368.00
C400T3C400T4C400T5C400T9 �
C400T10 �
C400T11 �
68.5068.5068.50
197.00197.00365.00
START/STOP Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights
STU
201.00385.00569.00
C400T13——
99.50——
ON/OFF Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights
VWX
201.00385.00569.00
C400T14——
99.50——
Rating Code Letter Rating Code Letter Rating Code Letter
120V 60 Hz208V 60 Hz
AE
240V 60 Hz380V 50 Hz
BL
480V 60 Hz600V 60 Hz
CD
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
April 2007
CA03902004E For more information visit: www.eaton.com
27Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedProduct Family Overview
Catalog Number SelectionTable 35. Solid-State Enclosed Control Catalog Numbering System
� DIM = Digital Interface Module.
E C S 9 0 S 1 C A A
Type
S = Solid-State
Class Page
93 = Non-combination S811 IT. Soft Start with DIM �94 = Combination S811 IT. Soft Start with Fusible
Disconnect and DIM �95 = Combination S811 IT. Soft Start with HMCP and
DIM �
2829
30
Amps
S752 S801/S811
J = .8K = 1.9L = 4.4M = 9N = 16P = 27R = 50
Q = 37S = 66V = 105W = 135Y = 180
Z = 2401 = 3042 = 3603 = 4204 = 500
5 = 6506 = 7207 = 8508 = 1000
Voltage
B = 230VC = 460VD = 575V
E = 200VQ = 24V DC
Cover Control
See Table 34 for Options
Disconnect Fuse Clip Ratings
A = NoneB = 30A/250V RC = 30A/600V RD = 60A/250V RE = 60A/600V RF = 100A/250V R
G = 100A/600V RH = 200A/250V RJ = 200A/600V RK = 400A/250V RL = 400A/600V RM = 600A/250V R
N = 600A/600V RP = 800A/600V LQ = 1200A/600V LR = 1600A/600V LS = 2000A/600V LT = by Description
Breaker
A = NoneB = 3AC = 7AD = 15AE = 30A
F = 50AW = 70AG = 100AH = 150AJ = 250A
K = 400AL = 600AP = 1200AQ = 1600A
Enclosure Type
1 = Type 12 = Type 3R3 = Type 44 = Type 4X (304-Grade SS)6 = Type 7/98 = Type 129 = Type 4X (316-Grade SS)
April 2007
28
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedNon-combination
Table 36. Class ECS93 — S811 IT. Soft Starter Enclosures — Non-combination with DIM �
� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).
� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.
� Based on 1.0 Service Factor. For 1.15 consult Eaton.
� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS93S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.
� Digital Interface Module (DIM) is mounted on door as standard.
Amps MotorVoltage
hp��
CoilVoltage �
Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
Frame Size — 65 mm37A 200V
230V460V575V
10102530
24V DC ECS93Q1EAAECS93Q1BAAECS93Q1CAAECS93Q1DAA
ECS93Q2EAAECS93Q2BAAECS93Q2CAAECS93Q2DAA
ECS93Q4EAAECS93Q4BAAECS93Q4CAAECS93Q4DAA
ECS93Q6EAAECS93Q6BAAECS93Q6CAAECS93Q6DAA
ECS93Q8EAAECS93Q8BAAECS93Q8CAAECS93Q8DAA
S811N37N3S
66A 200V230V460V575V
20205060
24V DC ECS93S1EAAECS93S1BAAECS93S1CAAECS93S1DAA
ECS93S2EAAECS93S2BAAECS93S2CAAECS93S2DAA
ECS93S4EAAECS93S4BAAECS93S4CAAECS93S4DAA
ECS93S6EAAECS93S6BAAECS93S6CAAECS93S6DAA
ECS93S8EAAECS93S8BAAECS93S8CAAECS93S8DAA
S811N66N3S
Frame Size — 110 mm105A 200V
230V460V575V
304075
100
24V DC ECS93V1EAAECS93V1BAAECS93V1CAAECS93V1DAA
ECS93V2EAAECS93V2BAAECS93V2CAAECS93V2DAA
ECS93V4EAAECS93V4BAAECS93V4CAAECS93V4DAA
ECS93V6EAAECS93V6BAAECS93V6CAAECS93V6DAA
ECS93V8EAAECS93V8BAAECS93V8CAAECS93V8DAA
S811R10N3S
135A 200V230V460V575V
4050
100125
24V DC ECS93W1EAAECS93W1BAAECS93W1CAAECS93W1DAA
ECS93W2EAAECS93W2BAAECS93W2CAAECS93W2DAA
ECS93W4EAAECS93W4BAAECS93W4CAAECS93W4DAA
ECS93W6EAAECS93W6BAAECS93W6CAAECS93W6DAA
ECS93W8EAAECS93W8BAAECS93W8CAAECS93W8DAA
S811R13N3S
Frame Size — 200 mm180A 200V
230V460V575V
6060
150150
24V DC ECS93Y1EAAECS93Y1BAAECS93Y1CAAECS93Y1DAA
ECS93Y2EAAECS93Y2BAAECS93Y2CAAECS93Y2DAA
ECS93Y4EAAECS93Y4BAAECS93Y4CAAECS93Y4DAA
ECS93Y6EAAECS93Y6BAAECS93Y6CAAECS93Y6DAA
ECS93Y8EAAECS93Y8BAAECS93Y8CAAECS93Y8DAA
S811T18N3S
240A 200V230V460V575V
7575
200200
24V DC ECS93Z1EAAECS93Z1BAAECS93Z1CAAECS93Z1DAA
ECS93Z2EAAECS93Z2BAAECS93Z2CAAECS93Z2DAA
ECS93Z4EAAECS93Z4BAAECS93Z4CAAECS93Z4DAA
ECS93Z6EAAECS93Z6BAAECS93Z6CAAECS93Z6DAA
ECS93Z8EAAECS93Z8BAAECS93Z8CAAECS93Z8DAA
S811T24N3S
304A 200V230V460V575V
100100250300
24V DC ECS9311EAAECS9311BAAECS9311CAAECS9311DAA
ECS9312EAAECS9312BAAECS9312CAAECS9312DAA
ECS9314EAAECS9314BAAECS9314CAAECS9314DAA
ECS9316EAAECS9316BAAECS9316CAAECS9316DAA
ECS9318EAAECS9318BAAECS9318CAAECS9318DAA
S811T30N3S
Frame Size — 290 mm360A 200V
230V460V575V
125150300350
24V DC ECS9321EAAECS9321BAAECS9321CAAECS9321DAA
ECS9322EAAECS9322BAAECS9322CAAECS9322DAA
ECS9324EAAECS9324BAAECS9324CAAECS9324DAA
ECS9326EAAECS9326BAAECS9326CAAECS9326DAA
ECS9328EAAECS9328BAAECS9328CAAECS9328DAA
S811V36N3S
420A 200V230V460V575V
150175350450
24V DC ECS9331EAAECS9331BAAECS9331CAAECS9331DAA
ECS9332EAAECS9332BAAECS9332CAAECS9332DAA
ECS9334EAAECS9334BAAECS9334CAAECS9334DAA
ECS9336EAAECS9336BAAECS9336CAAECS9336DAA
ECS9338EAAECS9338BAAECS9338CAAECS9338DAA
S811V42N3S
500A 200V230V460V575V
150200400500
24V DC ECS9341EAAECS9341BAAECS9341CAAECS9341DAA
ECS9342EAAECS9342BAAECS9342CAAECS9342DAA
ECS9344EAAECS9344BAAECS9344CAAECS9344DAA
ECS9346EAAECS9346BAAECS9346CAAECS9346DAA
ECS9348EAAECS9348BAAECS9348CAAECS9348DAA
S811V50N3S
650A 200V230V460V575V
250250500600
24V DC ECS9351EAAECS9351BAAECS9351CAAECS9351DAA
ECS9352EAAECS9352BAAECS9352CAAECS9352DAA
ECS9354EAAECS9354BAAECS9354CAAECS9354DAA
ECS9356EAAECS9356BAAECS9356CAAECS9356DAA
ECS9358EAAECS9358BAAECS9358CAAECS9358DAA
S811V65N3S
720A 230V460V575V
300600700
24V DC ECS9361BAAECS9361CAAECS9361DAA
ECS9362BAAECS9362CAAECS9362DAA
ECS9364BAAECS9364CAAECS9364DAA
ECS9366BAAECS9366CAAECS9366DAA
ECS9368BAAECS9368CAAECS9368DAA
S811V72N3S
850A 230V460V575V
350700900
24V DC ECS9371BAAECS9371CAAECS9371DAA
ECS9372BAAECS9372CAAECS9372DAA
ECS9374BAAECS9374CAAECS9374DAA
ECS9376BAAECS9376CAAECS9376DAA
ECS9378BAAECS9378CAAECS9378DAA
S811V85N3S
1000A 230V460V575V
400800
1000
24V DC ECS9381BAAECS9381CAAECS9381DAA
ECS9382BAAECS9382CAAECS9382DAA
ECS9384BAAECS9384CAAECS9384DAA
ECS9386BAAECS9386CAAECS9386DAA
ECS9388BAAECS9388CAAECS9388DAA
S811V10N3S
Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
April 2007
CA03902004E For more information visit: www.eaton.com
29Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedCombination with Fusible Disconnect
Table 37. Class ECS94 – S811 IT. Soft Starter Enclosures — Combination with Fusible Disconnect and DIM �
� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).
� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.
� Based on 1.0 Service Factor. For 1.15 consult Eaton.
� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS94S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.
� Consult Eaton.
� Digital Interface Module (DIM) is mounted on door as standard.
Amps MotorVoltage
hp��
CoilVoltage �
SwitchRating
Type 1 Type 3R Type 4X � Type 12 Component Soft Starter (Open)
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
Frame Size — 65 mm37A 200V 3
1024V DC 30A
60AECS94Q1EABECS94Q1EAD
ECS94Q2EABECS94Q2EAD
ECS94Q4EABECS94Q4EAD
ECS94Q8EABECS94Q8EAD
S811N37N3S
230V 7-1/210
30A60A
ECS94Q1BABECS94Q1BAD
ECS94Q2BABECS94Q2BAD
ECS94Q4BABECS94Q4BAD
ECS94Q8BABECS94Q8BAD
S811N37N3S
460V 1525
30A60A
ECS94Q1CACECS94Q1CAE
ECS94Q2CACECS94Q2CAE
ECS94Q4CACECS94Q4CAE
ECS94Q8CACECS94Q8CAE
S811N37N3S
575V 2030
30A60A
ECS94Q1DACECS94Q1DAE
ECS94Q2DACECS94Q2DAE
ECS94Q4DACECS94Q4DAE
ECS94Q8DACECS94Q8DAE
S811N37N3S
66A 200V 1020
24V DC 60A100A
ECS94S1EADECS94S1EAF
ECS94S2EADECS94S2EAF
ECS94S4EADECS94S4EAF
ECS94S8EADECS94S8EAF
S811N66N3S
230V 1520
60A100A
ECS94S1BADECS94S1BAF
ECS94S2BADECS94S2BAF
ECS94S4BADECS94S4BAF
ECS94S8BADECS94S8BAF
S811N66N3S
460V 50 100A ECS94S1CAG ECS94S2CAG ECS94S4CAG ECS94S8CAG S811N66N3S
575V 4060
60A100A
ECS94S1DAEECS94S1DAG
ECS94S2DAEECS94S2DAG
ECS94S4DAEECS94S4DAG
ECS94S8DAEECS94S8DAG
S811N66N3S
Frame Size — 110 mm105A 200V
230V460V575V
304075100
24V DC 200A200A200A200A
ECS94V1EAHECS94V1BAHECS94V1CAJECS94V1DAJ
ECS94V2EAHECS94V2BAHECS94V2CAJECS94V2DAJ
ECS94V4EAHECS94V4BAHECS94V4CAJECS94V4DAJ
ECS94V8EAHECS94V8BAHECS94V8CAJECS94V8DAJ
S811R10N3S
135A 200V230V460V575V
4050100125
24V DC 200A200A200A200A
ECS94W1EAHECS94W1BAHECS94W1CAJECS94W1DAJ
ECS94W2EAHECS94W2BAHECS94W2CAJECS94W2DAJ
ECS94W4EAHECS94W4BAHECS94W4CAJECS94W4DAJ
ECS94W8EAHECS94W8BAHECS94W8CAJECS94W8DAJ
S811R13N3S
Frame Size — 200 mm180A 200V
230V460V575V
6060150150
24V DC 400A400A400A400A
ECS94Y1EAKECS94Y1BAKECS94Y1CALECS94Y1DAL
ECS94Y2EAKECS94Y2BAKECS94Y2CALECS94Y2DAL
ECS94Y4EAKECS94Y4BAKECS94Y4CALECS94Y4DAL
ECS94Y8EAKECS94Y8BAKECS94Y8CALECS94Y8DAL
S811T18N3S
240A 200V230V460V575V
7575200200
24V DC 400A400A400A400A
ECS94Z1EAKECS94Z1BAKECS94Z1CALECS94Z1DAL
ECS94Z2EAKECS94Z2BAKECS94Z2CALECS94Z2DAL
ECS94Z4EAKECS94Z4BAKECS94Z4CALECS94Z4DAL
ECS94Z8EAKECS94Z8BAKECS94Z8CALECS94Z8DAL
S811T24N3S
304A 200V230V460V575V
100100250300
24V DC 400A400A400A400A
ECS9411EAKECS9411BAKECS9411CALECS9411DAL
ECS9412EAKECS9412BAKECS9412CALECS9412DAL
ECS9414EAKECS9414BAKECS9414CALECS9414DAL
ECS9418EAKECS9418BAKECS9418CALECS9418DAL
S811T30N3S
Frame Size — 290 mm360A 200V
230V460V575V
125125300350
24V DC 600A600A600A600A
ECS9421EAMECS9421BAMECS9421CANECS9421DAN
ECS9422EAMECS9422BAMECS9422CANECS9422DAN
ECS9424EAMECS9424BAMECS9424CANECS9424DAN
ECS9428EAMECS9428BAMECS9428CANECS9428DAN
S811V36N3S
420A 200V230V460V575V
150150350450
24V DC 600A600A600A600A
ECS9431EAMECS9431BAMECS9431CANECS9431DAN
ECS9432EAMECS9432BAMECS9432CANECS9432DAN
ECS9434EAMECS9434BAMECS9434CANECS9434DAN
ECS9438EAMECS9438BAMECS9438CANECS9438DAN
S811V42N3S
500A 200V230V460V575V
150200400500
24V DC 800A800A800A800A
ECS9441EAPECS9441BAPECS9441CAPECS9441DAP
ECS9442EAPECS9442BAPECS9442CAPECS9442DAP
ECS9444EAPECS9444BAPECS9444CAPECS9444DAP
ECS9448EAPECS9448BAPECS9448CAPECS9448DAP
S811V50N3S
650A 460V575V
500600
24V DC 800A800A
ECS9451CAPECS9451DAP
ECS9452CAPECS9452DAP
ECS9454CAPECS9454DAP
ECS9458CAPECS9458DAP
S811V65N3S
720A 460V575V
600700
24V DC 1200A1200A
ECS9461CAQECS9461DAQ
ECS9462CAQECS9462DAQ
ECS9464CAQECS9464DAQ
ECS9468CAQECS9468DAQ
S811V72N3S
850A 460V575V
700800
24V DC 1600A1600A
ECS9471CARECS9471DAR
ECS9472CARECS9472DAR
ECS9474CARECS9474DAR
ECS9478CARECS9478DAR
S811V85N3S
1000A 230V460V575V
4008001000
24V DC ���
ECS9481BA_ �
ECS9481CA_ �
ECS9481DA_ �
ECS9482BA_ �
ECS9482CA_ �
ECS9482DA_ �
ECS9484BA_ �
ECS9484CA_ �
ECS9484DA_ �
ECS9488BA_ �
ECS9488CA_ �
ECS9488DA_ �
S811V10N3S
Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . Page 21
April 2007
30
For more information visit: www.eaton.com CA03902004E
Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedCombination with Breaker
Table 38. Class ECS95 — S811 IT. Soft Starter Enclosures — Combination with Breaker and DIM �
� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS90S1EAA becomes ECS90S1QAA-C35).
� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.
� Based on 1.0 Service Factor. For 1.15 consult Eaton.
� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS95S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.
� Digital Interface Module (DIM) is mounted on door as standard.
Amps MotorVoltage
hp��
1.0S.F.
CoilVoltage �
CircuitBreakerType
Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
Frame Size 65 mm37A 200V 1/2
1310
24V DC 7A15A30A50A
ECS95Q1EACECS95Q1EADECS95Q1EAEECS95Q1EAF
ECS95Q2EACECS95Q2EADECS95Q2EAEECS95Q2EAF
ECS95Q4EACECS95Q4EADECS95Q4EAEECS95Q4EAF
ECS95Q6EACECS95Q6EADECS95Q6EAEECS95Q6EAF
ECS95Q8EACECS95Q8EADECS95Q8EAEECS95Q8EAF
S811N37N3S
230V 12310
24V DC 7A15A30A50A
ECS95Q1BACECS95Q1BADECS95Q1BAEECS95Q1BAF
ECS95Q2BACECS95Q2BADECS95Q2BAEECS95Q2BAF
ECS95Q4BACECS95Q4BADECS95Q4BAEECS95Q4BAF
ECS95Q6BACECS95Q6BADECS95Q6BAEECS95Q6BAF
ECS95Q8BACECS95Q8BADECS95Q8BAEECS95Q8BAF
S811N37N3S
460V 3/4251025
24V DC 3A7A15A30A50A
ECS95Q1CABECS95Q1CACECS95Q1CADECS95Q1CAEECS95Q1CAF
ECS95Q2CABECS95Q2CACECS95Q2CADECS95Q2CAEECS95Q2CAF
ECS95Q4CABECS95Q4CACECS95Q4CADECS95Q4CAEECS95Q4CAF
ECS95Q6CABECS95Q6CACECS95Q6CADECS95Q6CAEECS95Q6CAF
ECS95Q8CABECS95Q8CACECS95Q8CADECS95Q8CAEECS95Q8CAF
S811N37N3S
575V 137-1/21530
24V DC 3A7A15A30A50A
ECS95Q1DABECS95Q1DACECS95Q1DADECS95Q1DAEECS95Q1DAF
ECS95Q2DABECS95Q2DACECS95Q2DADECS95Q2DAEECS95Q2DAF
ECS95Q4DABECS95Q4DACECS95Q4DADECS95Q4DAEECS95Q4DAF
ECS95Q6DABECS95Q6DACECS95Q6DADECS95Q6DAEECS95Q6DAF
ECS95Q8DABECS95Q8DACECS95Q8DADECS95Q8DAEECS95Q8DAF
S811N37N3S
66A 200V 1020
24V DC 50A100A
ECS95S1EAFECS95S1EAG
ECS95S2EAFECS95S2EAG
ECS95S4EAFECS95S4EAG
ECS95S6EAFECS95S6EAG
ECS95S8EAFECS95S8EAG
S811N66N3S
230V 1520
24V DC 70A100A
ECS95S1BAWECS95S1BAG
ECS95S2BAWECS95S2BAG
ECS95S4BAWECS95S4BAG
ECS95S6BAWECS95S6BAG
ECS95S8BAWECS95S8BAG
S811N66N3S
460V 50 24V DC 100A ECS95S1CAG ECS95S2CAG ECS95S4CAG ECS95S6CAG ECS95S8CAG S811N66N3S
575V 60 24V DC 100A ECS95S1DAG ECS95S2DAG ECS95S4DAG ECS95S6DAG ECS95S8DAG S811N66N3S
Frame Size 110 mm105A 200V 30 24V DC 150A ECS95V1EAH ECS95V2EAH ECS95V4EAH ECS95V6EAH ECS95V8EAH S811R10N3S
230V 40 24V DC 150A ECS95V1BAH ECS95V2BAH ECS95V4BAH ECS95V6BAH ECS95V8BAH S811R10N3S
460V 75 24V DC 150A ECS95V1CAH ECS95V2CAH ECS95V4CAH ECS95V6CAH ECS95V8CAH S811R10N3S
575V 100 24V DC 150A ECS95V1DAH ECS95V2DAH ECS95V4DAH ECS95V6DAH ECS95V8DAH S811R10N3S
135A 200V230V460V575V
4050100125
24V DC 150A150A150A150A
ECS95W1EAHECS95W1BAHECS95W1CAHECS95W1DAH
ECS95W2EAHECS95W2BAHECS95W2CAHECS95W2DAH
ECS95W4EAHECS95W4BAHECS95W4CAHECS95W4DAH
ECS95W6EAHECS95W6BAHECS95W6CAHECS95W6DAH
ECS95W8EAHECS95W8BAHECS95W8CAHECS95W8DAH
S811R13N3S
Frame Size 200 mm180A 200V
230V460V575V
6060150150
24V DC 250A250A250A250A
ECS95Y1EAJECS95Y1BAJECS95Y1CAJECS95Y1DAJ
ECS95Y2EAJECS95Y2BAJECS95Y2CAJECS95Y2DAJ
ECS95Y4EAJECS95Y4BAJECS95Y4CAJECS95Y4DAJ
ECS95Y6EAJECS95Y6BAJECS95Y6CAJECS95Y6DAJ
ECS95Y8EAJECS95Y8BAJECS95Y8CAJECS95Y8DAJ
S811T18N3S
240A 200V230V460V575V
7575200200
24V DC 400A250A400A250A
ECS95Z1EAKECS95Z1BAJECS95Z1CAKECS95Z1DAJ
ECS95Z2EAKECS95Z2BAJECS95Z2CAKECS95Z2DAJ
ECS95Z4EAKECS95Z4BAJECS95Z4CAKECS95Z4DAJ
ECS95Z6EAKECS95Z6BAJECS95Z6CAKECS95Z6DAJ
ECS95Z8EAKECS95Z8BAJECS95Z8CAKECS95Z8DAJ
S811T24N3S
304A 200V230V460V575V
100100250300
24V DC 400A400A400A400A
ECS9511EAKECS9511BAKECS9511CAKECS9511DAK
ECS9512EAKECS9512BAKECS9512CAKECS9512DAK
ECS9514EAKECS9514BAKECS9514CAKECS9514DAK
ECS9516EAKECS9516BAKECS9516CAKECS9516DAK
ECS9518EAKECS9518BAKECS9518CAKECS9518DAK
S811T30N3S
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . Page 21
April 2007
CA03902004E For more information visit: www.eaton.com
31Reduced Voltage Motor StartersIT. Solid-State Soft Starters — EnclosedDimensions
Table 38. Class ECS95 — S811 IT. Soft Starter Enclosures — Combination with Breaker and DIM � (Continued)
� All IT. soft starters are furnished with 24V DC coils and control power supplies. For 24V DC separate control, use Mod Code C35 and change the 8th digit to Q (i.e. ECS92S1EAF becomes ECS92S1QAF-C35).
� Standard duty horsepower ratings are for 300% ramp current, 30 seconds ramp time, and 3 starts per hour. Consult Eaton for other ratings.
� Based on 1.0 Service Factor. For 1.15 consult Eaton.
� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECS95S4EAA. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5.
� Digital Interface Module (DIM) is mounted on door as standard.
DimensionsTable 39. Minimum Enclosure Box Numbers
� Enclosure space will also accommodate for an IT. Power Supply, two 4-pole relays, CPT, and terminal blocks. Also includes space for a DNA module or MOV.
� Same as footnote �, but CPT is not included. Upsize to 7A enclosure to include space for a CPT and a full voltage bypass contactor.
Enclosure may be reduced to an A1, with all space for all items as in footnote �, excluding relays and CPTs.
Same as footnote �, but CPT is not included. Upsize to B1 enclosure to include space for a CPT and a full voltage bypass contactor.
Note: See Enclosed Control Product Focus for Box Dimensions for Type 1, 3R, 4X, 7/9 and 12.
Amps MotorVoltage
hp��
1.0S.F.
CoilVoltage �
CircuitBreakerType
Type 1 Type 3R Type 4X � Type 7/9 Type 12 Component Soft Starter (Open)
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
CatalogNumber
Frame Size 290 mm360A 200V
230V460V575V
125150300350
24V DC HMCP 600AHMCP 400AHMCP 600AHMCP 400A
ECS9521EALECS9521BAKECS9521CALECS9521DAK
ECS9522EALECS9522BAKECS9522CALECS9522DAK
ECS9524EALECS9524BAKECS9524CALECS9524DAK
————
ECS9528EALECS9528BAKECS9528CALECS9528DAK
S811V36N3S
420A 200V460V575V
150350450
24V DC HMCP 600AHMCP 600AHMCP 600A
ECS9531EALECS9531CALECS9531DAL
ECS9532EALECS9532CALECS9532DAL
ECS9534EALECS9534CALECS9534DAL
———
ECS9538EALECS9538CALECS9538DAL
S811V42N3S
500A 230V460V575V
200400500
24V DC HMCP 600AHMCP 600AHMCP 600A
ECS9541BALECS9541CALECS9541DAL
ECS9542BALECS9542CALECS9542DAL
ECS9544BALECS9544CALECS9544DAL
———
ECS9548BALECS9548CALECS9548DAL
S811V50N3S
650A 200V230V460V460V575V
200250450500600
24V DC HMCP 1200AHMCP 1200AHMCP 600AHMCP 1200AHMCP 1200A
ECS9551EAPECS9551BAPECS9551CALECS9551CAPECS9551DAP
ECS9552EAPECS9552BAPECS9552CALECS9552CAPECS9552DAP
ECS9554EAPECS9554BAPECS9554CALECS9554CAPECS9554DAP
—————
ECS9558EAPECS9558BAPECS9558CALECS9558CAPECS9558DAP
S811V65N3S
720A 230V460V575V
300600700
24V DC HMCP 1200AHMCP 1200AHMCP 1200A
ECS9561BAPECS9561CAPECS9561DAP
ECS9562BAPECS9562CAPECS9562DAP
ECS9564BAPECS9564CAPECS9564DAP
———
ECS9568BAPECS9568CAPECS9568DAP
S811V72N3S
850A 460V575V
700800
24V DC HMCP 1200AHMCP 1200A
ECS9571CAPECS9571DAP
ECS9572CAPECS9572DAP
ECS9574CAPECS9574DAP
——
ECS9578CAPECS9578DAP
S811V85N3S
1000A 230V460V575V
400800
1000
24V DC RD 1600RD 1600RD 1600
ECS9581BAQECS9581CAQECS9581DAQ
ECS9582BAQECS9582CAQECS9582DAQ
ECS9584BAQECS9584CAQECS9584DAQ
———
ECS9588BAQECS9588CAQECS9588DAQ
S811V10N3S
Rating SSRV Non-combination
Combination with Fuses
Combination with HMCP
Box No. � Box No. � Box No. �
.8 – 27A37A50A66A
105A135A180A
S752S801/S811S752S801/S811S801/S811S801/S811S801/S811
6A �7A6A �7A7AB1C
B1 B1CCDDE
A1 A1 A1 A1 B1CE
240A304A360A420A500A
S801/S811S801/S811S801/S811S801/S811S801/S811
G1G1G11010
F1EF1EF1EF1EF1E
EEEEE
650A720A850A
S801/S811S801/S811S801/S811
101010
F1EF1EF1E
F1EF1EF1E
1000A S801/S811 10 F1E F1E
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . Page 26Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19Technical Data . . . . . . . . . . . . . . . . . . . . . . . . Page 21
Eaton CorporationElectrical Group1000 Cherrington ParkwayMoon Township, PA 15108United States877-ETN CARE (877-386-2273)Eaton.com