Transcript
Page 1: Diesel Generator Set MTU 12V2000 DS1000...MTU 12V2000 DS1000 Diesel Generator Set Product highlights 380V - 415V/50 Hz/prime/fuel consumption optimized 12V2000G26F/air charge air cooling

MTU 12V2000 DS1000Diesel Generator Set

Product highlights

380V-415V/50Hz/prime/fuelconsumptionoptimized12V2000G26F/air charge air cooling

Bene� ts— Lowfuelconsumption— Optimizedsystemintegrationability— Highreliabilityandavailabilityofpower— Longmaintenanceintervals— Optimizedratiobetweensizeandpower— Wideoperatingrangewithoutderating

Support— Globalproductsupportoffered

Standards— Engine-generatorsetisdesignedandmanufacturedinfacilitiescertifiedtostandardsISO2008:9001andISO2004:14001

— GeneratorsetcompliestoG3accordingtoISO8528— GeneratormeetsNEMAMG1,BS5000,ISO,DINENandIECstandards

— NFPA110

Power rating— Systemrating:800kVA— AcceptsratedloadinonestepperNFPA110— GeneratorsetcompliestoG3accordingtoISO8528-5— GeneratorsetexceedsloadstepsaccordingtoISO8528-5

Performance assurance certi� cation (PAC)— Engine-generatorsettestedtoISO8528-5fortransientresponse— 75%loadfactorforprimepowerapplications— Verifiedproductdesign,qualityandperformanceintegrity— Allenginesystemsareprototypeandfactorytested

Complete range of accessories available— Controlpanel— Power panel— Fuelsystem— Fuelconnectionswithshut-offvalvemountedtobaseframe— Starting/chargingsystem— Exhaustsystem— Mechanicalradiator— Oversizedvoltagealternators

Emissions— Fuelconsumptionoptimized— TA-Luft,Tier2compliantandNEA(ORDE)optimizationoptionallyavailable

Certi� cations— CEcertificationoption— VDE4110Certification

Optionalequipmentandfinishingshown.Standardmayvary.Optionalequipmentandfinishingshown.Standardmayvary.

Page 2: Diesel Generator Set MTU 12V2000 DS1000...MTU 12V2000 DS1000 Diesel Generator Set Product highlights 380V - 415V/50 Hz/prime/fuel consumption optimized 12V2000G26F/air charge air cooling

Application data 1)

Engine Fuel consump. opt. Emission opt. 2)

Manufacturer MTU MTU Model 12V2000G26F 12V2000G26F Type 4-cycle 4-cycle Arrangement 12V 12V Displacement: l 26.8 26.8 Bore: mm 135 135 Stroke: mm 156 156 Compression ratio 17.5 17.5 Rated speed: rpm 1500 1500 Engine governor ADEC (ECU 9) ADEC (ECU 9) Speed regulation ± 0.25% ± 0.25% Max power: kWm 709 709 Mean effective pressure: bar 21.2 21.2 Air cleaner dry dry

Fuel systemMaximum fuel lift: m 5 5 Total fuel flow: l/min 30 30

Fuel consumption 2)

At 100% of power rating: l/hr g/kWh 162/190 167/196 At 75% of power rating: l/hr g/kWh 124/193 127/199 At 50% of power rating: l/hr g/kWh 87/204 90/211

Lube oil systemTotal oil system capacity: l 80 80 Max. lube oil temp. (alarm): °C 103 103 Max. lube oil temp. (shutdown): °C 105 105 Min. lube oil pressure (alarm): bar 4.5 4.5 Min. lube oil pressure (shutdown): bar 4 4

Combustion air requirementsCombustion air volume: m3/s 0.79 0.91 Max. air intake restriction: mbar 40 40

Cooling/radiator system Fuel consump. opt. Emission opt. 2)

Coolant flow rate (HT circuit): m3/hr 31.6 31.6 Heat rejection to coolant: kW 290 280 Heat radiated to charge air cooling: kW 120 150 Heat radiated to ambient: kW 35 35 Fan power for mech. radiator (40°C): 34 34 Fan power for mech. radiator (50°C): 51.1 51.1 Air flow required for mech. radiator (40°C) cooled unit: m3/min 969 969 Air flow required for mech. radiator (50°C) cooled unit: m3/min 1328 1328 Engine coolant capacity (without cooling equipment): l 63 63 Radiator coolant capacity (40°C): l 59 59 Radiator coolant capacity (50°C): l 140 140 Max. coolant temperature (warning): °C 102 102 Max. coolant temperature (shutdown): °C 105 105

Exhaust systemExhaust gas temp. (after turbocharger): °C 540 505 Exhaust gas volume: m³/s 2.2 2.4 Maximum allowable back pressure: mbar 50 50 Minimum allowable back pressure: mbar 30 30

GeneratorProtection class IP23 IP23 Insulation class H H Voltage regulation (steady state) ± 0.25% ± 0.25% Rado interference class N N

1 All data refers only to the engine and is based on ISO standard conditions (25°C and 100m above sea level).

2 Emission optimized data refer to TA-Luft optimized and NEA (ORDE) optimized/Tier 2 compliant engines.

Page 3: Diesel Generator Set MTU 12V2000 DS1000...MTU 12V2000 DS1000 Diesel Generator Set Product highlights 380V - 415V/50 Hz/prime/fuel consumption optimized 12V2000G26F/air charge air cooling

Representsstandardfeatures

Representsoptionalfeatures

Standardandoptionalfeatures

System ratings (kW/kVA)

Generator model Voltage with mechanical radiator

kWel kVA* AMPS

LeroySomerLSA49.3L9 (Lowvoltage LeroySomerstandard)

380 V 640 800 1215

400 V 640 800 1155

415 V 640 800 1113

LeroySomerLSA50.2M6 (Lowvoltage LeroySomeroversized)

380 V 640 800 1215

400 V 640 800 1155

415 V 640 800 1113

Marathon575RSL7181 (Lowvoltage Marathonstandard)

380 V 640 800 1215

400 V 640 800 1155

415 V 640 800 1113

Marathon740RSL7183 (Lowvoltage Marathonoversized)

380 V 640 800 1215

400 V 640 800 1155

415 V 640 800 1113 *cosphi=0.8

Engine

4-Cycle Standardsinglestageairfilter Oildrainextension&shut-offvalve Fullflowoilfilters Closedcrankcaseventilation

ADECelectronicisochronousenginegovernor Commonrailfuelinjection Dryexhaustmanifold Electricstartingmotor(24V)

Fuelconsumptionoptimizedengine TA-Luftoptimizedengine Tier2optimizedengine NEA(ORDE)optimizedengine

Generator

LeroySomerlowvoltagegenerator MeetsNEMAMG1,BS5000, IEC60034-1,VDE0530, DINEN12601,AS1359 andISO8528requirements Superiorvoltagewaveform Solidstate,volts-per-Hertzregulator 4polethree-phasesynchronous generator Brushless,self-excited,self-regulating,self-ventilated Digitalvoltageregulator Anticondensationheater StatorwindingY-connected, accessibleneutral(broughtout)

ProtectionIP23 lessthan5%harmonicdistorsion 2/3 pitch stator windings Noloadtofullloadregulation ±0.25%voltageregulationnoloadto fullload InsulationclassH,utilizationacc.toH RadiosuppressionEN55011, group1,cl.B Shortcircuitcapability3xInfor10sec Sustainedshortcircuitcurrentofupto300%oftheratedcurrentforupto10seconds(LeroySomergenerator) WindingandbearingRTDs (withoutmonitoring)

ExcitationbyAREP+PMI MountingofCT´s:3x2coreCT´s Voltagesetpointadjustment±10V Sustainedshortcircuitcurrentofupto250%oftheratedcurrentforupto10seconds(Marathongenerator) Marathonlowvoltagegenerator Oversizedgenerator

Page 4: Diesel Generator Set MTU 12V2000 DS1000...MTU 12V2000 DS1000 Diesel Generator Set Product highlights 380V - 415V/50 Hz/prime/fuel consumption optimized 12V2000G26F/air charge air cooling

Standard and optional features

Representsstandardfeatures

Representsoptionalfeatures

Cooling system

Jacketwaterpump Thermostat(s)

Airchargeaircooling Mechanicalradiator

Jacketwaterheater

Power Panel

Availablein600x600 Phasemonitoringrelay230V/400V

Supplyforbatterycharger Supplyforjacketwaterheater

Plugsocketcabinetfor230V compatibleEuro

Fuel system

Flexiblefuelconnectorsmountedto baseframe

Fuelfilterwithwaterseparator Switchablefuelfilterwithwaterseparator

Fuel cooler

Starting/charging system

24Vstarter Starterbatteries,cables,rack, disconnect switch

Batterycharger Redundantstarter2x7.5KW

Mounting system

Weldedbaseframe Resilientengineandgeneratormounting Modularbaseframedesign

Exhaust system

Exhaustbellowswithconnectionflange Exhaustsilencerwith10dB(A)soundattenuation

Exhaustsilencerwith30dB(A)soundattenuation Exhaustsilencerwith40dB(A)soundattenuation

Y-connection-pipe

Control Panel

Pre-wiredcontrolcabinetforeasy applicationofcustomizedcontroller(V1+) Islandoperation(V2) AutomaticmainsfailureoperationwithATS(V3a) Automaticmainsfailureoperation incl.controlofgeneratorandmainsbreaker(V3b) Islandparalleloperationofmultiplegensets(V4) Automaticmainsfailureoperationwithshort(<10s)mainsparallel overlapsynchronization(V5) Mainsparalleloperationofasinglegenset(V6)

Mainsparalleloperationofmultiplegensets(V7) Baslercontroller Deifcontroller Completesystemmetering Digitalmetering Engineparameters Generatorprotectionfunctions Engineprotection SAEJ1939engineECU communications Parametrizationsoftware Multilingualcapability Multipleprogrammablecontactinputs Multiplecontactoutputs

Eventrecording IP54frontpanelratingwith integratedgasket Differentexpansionmodules Remoteannunciator Daytankcontrol Generatorwindingtemperature monitoring Generatorbearingtemperature monitoring Differentialprotectionwith multi-functionprotectionrelay ModbusRTU-TCPgateway

Page 5: Diesel Generator Set MTU 12V2000 DS1000...MTU 12V2000 DS1000 Diesel Generator Set Product highlights 380V - 415V/50 Hz/prime/fuel consumption optimized 12V2000G26F/air charge air cooling

Rolls-Royce Groupwww.mtu-solutions.com/powergen

Weights and dimensions

Drawing above for illustration purposes only, based on a standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings.

Weightsanddimensionsarebasedonopenpowerunitsandareestimatesonly.Consultthefactoryforaccurateweightsanddimensionsforyourspecificengine-generatorset.

System Dimensions (L x W x H) Weight (dry/less tank)

Openpowerunit(OPU) 4120x1910x2190mm 5800kg

Sound data

— ConsultyourlocalMTUdistributorforsounddata.

Emissionsdata

— ConsultyourlocalMTUdistributorforemissionsdata.

Ratingdefinitionsandconditions

— Primepowerratingsapplytoinstallationswhereutilitypowerisunavailableorunreliable.Atvaryingload,thenumberofgeneratorsetoperatinghoursisunlimited.A10%overloadcapacityisavailableforonehourintwelve.RatingsareinaccordancewithISO8528-1,ISO3046-1,BS5514andAS2789. Averageloadfactor:≤75%.Operatinghours/year:unlimited

— ConsultyourlocalMTUdistributorforderatinginformation.

Subjecttochange.|3239531|Edition01/19|ESM2019-12.


Top Related