![Page 1: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/1.jpg)
EVERY LIFE HAS A PURPOSE…
9010 / 9020Controller
![Page 2: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/2.jpg)
9010 / 9020 Controller
![Page 3: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/3.jpg)
9010 / 9020 Controller
Target Markets
General Industry Oil, Gas &
Petrochemical Water & Wastewater LPG
![Page 4: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/4.jpg)
9010 / 9020 Control Card
9010 Single Channel Control Card Factory Configured
9020 Dual Channel Control Card Factory Configured
![Page 5: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/5.jpg)
9010 / 9020 Controller
Control Module Features Operates with complete range of
2- or 3-wire gas sensors including: Toxic Combustible Oxygen
User-friendly configurable operation Leading edge SMD technology throughout
![Page 6: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/6.jpg)
9010 / 9020 Controller
Control Module Features Provides real-time self-diagnostics Each module comes with an independent AC/DC
power supply transformer AC/DC automatic switching in case of
AC power failure User defined access codes prevent accidental or
undesired tampering
![Page 7: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/7.jpg)
9010 / 9020 Controller
Control Module Features Each module has two SPDT relays with change-over
contacts for verification of Warning and Alarm conditions
Default and configuration data stored in non-volatile memory
3 Adjustable Alarm levels for Caution, Warning & Alarm (indicated by LED’s)
![Page 8: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/8.jpg)
9010 / 9020 Display Features
4-digit back-lit LCD Choice of unit of
measure (LEL, LELm, PPM, % Vol, g/m3 or blank)
Alarm status Cal, Time-out / Off,
CWA Delay ON, Alarm inhibit
![Page 9: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/9.jpg)
9010 / 9020 Keypad Features
Simple 3-key operation Keypad allows for:
Configuration Calibration Routine operation
▲ ▼
![Page 10: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/10.jpg)
9010 / 9020 Output Signals
Analog (normal) - 0-20, 4-20 mA (selectable) isolated
Analog (fault) - 0,2,4,20 mA / frozen (selectable) RS 485 for connection to a printer
![Page 11: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/11.jpg)
9010 / 9020 Controller
Configuration and Calibration No tools required for adjustment Utilizes keypad Remote non-intrusive calibrator Adjustable Calibration Timer
Reminds user of selected calibration interval User selectable 0-999 days CAL message appears on display
![Page 12: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/12.jpg)
9020 Component Side View
![Page 13: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/13.jpg)
9010 / 9020 Enclosures
General Purpose Plastic Protection against dust and
rain 1 – 9010 (1 point) 1 – 9020 (2 points) 4 lbs
![Page 14: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/14.jpg)
9010 / 9020 Enclosures
Nema 4X Metal Protection against
dust and rain External Horn Acknowledge Button 5-10 – 9010
(up-to 10 points) 5-10 – 9020
(up-to 20 points) 67-100 lbs Also Available in Stainless Steel
![Page 15: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/15.jpg)
9010 / 9020 Enclosures
Explosion Proof Metal Suitable for Class 1, Div. 1
& Div. 2 areas 1-2 – 9010
(up-to 2 points) 1-2 – 9020
(up-to 4 points) 52-86 lbs
![Page 16: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/16.jpg)
9010 / 9020 Enclosures
Rack Mount Standard Rack Configuration Wiring in rear 10 – 9010 (up-to 10 points) 10 – 9020 (up-to 20 points) 23 lbs
![Page 17: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/17.jpg)
9010 / 9020 Sensor Options
Passive catalytic sensor Electrochemical sensor Infrared sensor (via specific interface PCB) Ultima® X Transmitters FlameGard® 5 Flame Detectors Ultima® MOS-5 Gas Detector Ultima® OPIR-5 Open Path Gas Monitor
![Page 18: E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller](https://reader035.vdocuments.net/reader035/viewer/2022081603/56649f505503460f94c73660/html5/thumbnails/18.jpg)
9010 / 9020 Controller