Transcript
Page 1: HiQ Solar AC Splice · HiQ Solar AC Splice ACSPL-40 Data Sheet What is it? • Compatible junction box suitable for combining up to 3 HiQ Solar inverters into one home run to an AC

HiQ Solar AC SpliceACSPL-40 Data Sheet

What is it?• Compatible junction box suitable for combining up

to 3 HiQ Solar inverters into one home run to an AC load center

Ideal for• Rooftop solar, carports

Features• Combine AC outputs

(2) TS208-5k75 208 Vac inverters 208 – 40 A OCPD(3) TS480-8k 480 Vac inverters – 40 A OCPD

• Small, inexpensive

Enclosure• Outdoor, weatherproof• NEMA4, polycarbonate enclosure• Corrosion resistant• UV resistant• Knockouts on bottom of enclosure• Mountable flat or upright• 2 or 3 gland fittings supplied with splice-box

SpecificationsElectricalAC voltage 208 to 600 VAC

3-phaseAC frequency 50/60 HzCurrent rating (3 HiQ inverters) 40 Aac continuousTerminal configuration 3 phase + neutralConductors•Branch•Inverter•Equipment Ground Conductor (EGC) per NEC 250.122

Copper only, 90 °C8 - 2/0 AWG 14-4 AWG10 AWG

Terminal torque•Branch•Inverter

120 Lb.-in20 Lb.-in

PhysicalDimensions (W x H x D) 213 x 213 x 132mm

(8.4 x 8.4 x 5.2”)Maximum allowable size for branch circuit conduit

2”

Environmental rating NEMA4Operating temperature range -40 to +65 oC

Ordering GuideItem Part Number DescriptionAC Splice ACSPL-40 AC Splice

NEMA4 enclosure. Includes 3 gland fittings for up to 3 inverter AC cables. Inverter AC cables must be ordered separately

Page 2: HiQ Solar AC Splice · HiQ Solar AC Splice ACSPL-40 Data Sheet What is it? • Compatible junction box suitable for combining up to 3 HiQ Solar inverters into one home run to an AC

© HiQ Solar Inc. 17th-Feb-2016, SPL-01-USData subject to change without notice

2030 Duane Avenue, Santa Clara, CA [email protected], www.hiqsolar.com

Conduit entry drilled hereAC whip glands


Top Related