Download - Solar Passive and Energy Efficient Building
![Page 1: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/1.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Elektro UK PetraJ
uru
sa
n T
ek
nik
Solar Passive and
Energy Efficient Building
Good Practices
From Petra Christian University
![Page 2: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/2.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Outline of Presentation
1. Why Energy Efficient in Buildings?
2. Evolution of Energy Efficient in Buildings
3. Examples of Energy Efficient Buildings
4. Conclusion
![Page 3: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/3.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
How much Energy spent in Buildings?
![Page 4: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/4.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
How much Energy spent in Buildings?
![Page 5: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/5.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Aspects of Energy Conscious Design
• Thermal Comfort aspect. – Heating and Cooling system
• Visual Comfort aspect.– Lighting system
Reference: Jimmy Priatman, Energy Efficient Architecture, Oct 2011
![Page 6: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/6.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Evolution of Energy Efficient in Building Design *)
1. Pre- Industrial Era (before 1800 AD)
2. Industrial Age (1800 – 1980 AD)
3. Post- Industrial Era (1980 – 2000)
4. Global Era (2000 – present)
*) Reference: Jimmy Priatman, Energy Efficient Architecture, Oct 2011
![Page 7: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/7.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Constrains in Design
ERA Resources Technology
Pre-industrial (before 1800)
Abundant Limited
Industrial Age(1800 – 1980)
Abundant Innovative[AC, Lamps, Elevators]
Post Industrial(1980 – 2000)
Limited Developed[energy efficient
appliances]
Global Era(2000 – present)
Depleted Advanced[renewable energy]
Reference: Jimmy Priatman, Energy Efficient Architecture, Oct 2011
![Page 8: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/8.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Pre-Industrial
![Page 9: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/9.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Industrial Age
• Thermal Comfort:
Air Conditioning system
• Visual Comfort:
Lamps
![Page 10: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/10.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Post Industrial
![Page 11: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/11.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Global Era
• Building Automation System.
![Page 12: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/12.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Three method of Control
• Passive Environmental ControlA design of utilizing the local climate controlled by building elements (roof, wall, floors, etc) without the help of electricity
• Active Environmental Control• A design that using technology and electrical instruments
to achieve the thermal and visual comfort
• Hybrid Environmental Control
First priority: Passive control, then hybrid and active control.
![Page 13: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/13.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Good Practices from Petra Christian University
![Page 14: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/14.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Best Practice - 1
EEI = 144 KWh/m2/yr
EEI = 88 KWh/m2/yr
Minimum Natioan EEI = 200 KWh/m2/yr
![Page 15: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/15.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Factor of success
• Orientation of building• Layout of rooms• Wall Windows ratio• Material for building’s envelope.• Energy saving equipments (Air Con and
Lamps)
![Page 16: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/16.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Best Practice - 2
![Page 17: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/17.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
No significant result
JANUARI
PEBRUARI
MARET
APRILM
EIJU
NIJU
LI
AGUSTUS
SEPTEMBER
OKTOBER
NOPEMBER
DESEMBER
-
50,000
100,000
150,000
200,000
250,000
2008
2009
2010
2011
![Page 18: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/18.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Possible reasons
• Human behavior.Lecturer “forgets” to bring their card. [now it is changed with finger ID]
• Classroom occupancy is already high.• There are other loads that are more
significant than AC and lamps in the class rooms.
![Page 19: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/19.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Good Practice - 3
House LuxPorch 60Living Room 120 - 250Dining Room 120 - 250Working Room 120 - 250Bed Room 120 - 250Bath Room 250Kitchen 250Garage 60
![Page 20: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/20.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Good Practice - 3
Rooms in school LuxClass Room 250Library 300Laboratory 500Drawing Room 750Canteen 200
![Page 21: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/21.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Good Practice - 3
Smart Lamp• Solar Cell for
light sensor• LED• PWM
[7.8 KHz]• ATMega8
![Page 22: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/22.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Good Practice – 4
Petra’s Green Building [2014]
• “V” Shaped • Energy Park:
– Solar Cell on top of the roof– Wind Turbine inside the “V” tunnel
• Water conservation system
![Page 23: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/23.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik
Conclusion
• Energy Efficient Building design should prioritize in Passive Environmental Control before applying the Active as well as Hybrid Environmental Control
• Human behavior and psychological barrier should be considered.
• Building Automation System could be an additional enhancement for EE Buildings
![Page 24: Solar Passive and Energy Efficient Building](https://reader036.vdocuments.net/reader036/viewer/2022062321/56813a0a550346895da1d8c8/html5/thumbnails/24.jpg)
Elektro UK PetraJ
uru
sa
n T
ek
nik