305-0076 Ver.1 Copyright © 2001-2003 Electroline Equipment Inc., 8265 St-Michel Blvd., Montréal, Québec H1Z 3E4 Tel. 800-461-3344 or (514) 374-6335 Fax (514) 374-2257 [email protected] DROPAmp TM Installation Instructions Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Do not use this apparatus near water. Clean only with a dry cloth. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The above instructions and warning apply only to the wall adapter. Materials supplied Electroline DROPAmp EDA-FT, EDA or ERA series Wall adapter, 120 VAC, 15 VDC (or 120 VAC, 18 VDC for two-way or return path models) Electroline Power Inserter model EDA-IC-F (optional) Materials not supplied 1” screws (#6) of an appropriate type for the mounting surface nylon screw anchors ( 3 /16” x 1”) coaxial cables with male F-type connectors grounding wire (#6–#14 gauge) Installation 1. With two 1” #6 screws, mount the DROPAmp on a wood, drywall, brick or cement surface. Use nylon screw anchors on all mounting surfaces other than wood. 2. To ground the DROPAmp, insert #6–#14 gauge grounding wire in the hole at the top left edge of the DROPAmp. Tighten the seizure screw with a #2 Phillips head screwdriver. 3. Connect the CATV drop cable to the DROPAmp’s RF IN connector. 4. Follow the Local Powering (A) or Remote Powering (B) instructions. A. For Local Powering A1. Connect the subscriber’s TV set(s) or cable converter(s) to the output(s) on the DROPAmp. Note that the ERA 4100 is normally used to connect a cable modem or interactive set-top box. Install 75-ohm terminators on any unused outputs. A2. Use coaxial cable with a male F-type connector at each end to connect the wall adapter to the DROPAmp’s PWR connector. The wall adapter’s F connector should be hand-tightened only. The maximum recommended length for the cable is 100 feet (30 meters), or 57 feet (17 meters) for the ERA 4100 model. Figure A: Example of Local Powering TM EDA 2400 PWR 15 VDC 270 mA 5 - 42 54 - 1000 MHz 6 kV Wall outlet power adapter *Unplug in order to reset. Insert ground wire To TVs or cable converters CATV signal input Mounting hole Mounting hole Hand-tighten only OUT2 +7dB OUT3 +7dB OUT4 +7dB OUT1+PWR +7dB Insert ground wire To TVs or cable converters CATV signal input Mounting hole RF OUTPUTS TM PWR 15 VDC EDA-FT08000 5-42 54-1000 MHz 6 kV PWR RF IN PWR REV LOSS 10 dB FWD GAIN 3 dB PWR LED REMOTE (TOP) Wall outlet power adapter *Unplug in order to reset. Hand-tighten only Mounting hole Troubleshooting: If the DROPAmp is not working (power LED is off or dim, or output signal is not amplified), check for a short circuit on the coaxial cable between the DROPAmp and the wall adapter. Repair the short circuit, and then reset the wall adapter as follows: Unplug the wall adapter from the power source, and wait 20 seconds. This resets the overload protection device (PTC), where applicable. Plug the wall adapter back into the power source. The DROPAmp’s green power LED should now be lit brightly. If the LED is dim, repeat the reset procedure. If problems persist, contact Electroline’s technical support department. B. For Remote Powering B1. With one 1” #6 screw, mount the Power Inserter on a wood, drywall, brick or cement surface. Use a nylon screw anchor on all mounting surfaces other than wood. B2. Run a coaxial cable from the RF TV connector on the Power Inserter to the subscriber’s TV set or cable converter. Note that the ERA 4100 model is normally connected to a cable modem or interactive set-top box. B3. Connect one end of the subscriber’s additional TV sets or cable converters to the remaining outputs on the DROPAmp. Install 75-ohm terminators on any unused outputs. On all models, do not connect anything to the PWR port. B4. Use coaxial cable with male F-type connectors at each end to connect the Power Inserter’s RF-PWR TO AMP connector to the DROPAmp’s remote power output (REMOTE PWR or OUT1). B5. Use coaxial cable with male F-type connectors at each end to connect the wall adapter to the Power Inserter’s PWR IN connector. The wall adapter’s F connector should be hand- tightened only. The maximum recommended length for the coaxial cables from the wall outlet to the DROPAmp is 100 feet (30 meters), or 21 feet (6 meters) for the ERA 4100 model. 5. Plug the wall adapter into an indoor power outlet. If properly connected, the DROPAmp’s green power LED will be lit. Figure B: Example of Remote Powering RF TV 5-1000 MHz RF-PWR TO AMP PWR IN TM OUT1+PWR +7dB OUT2 +7dB OUT3 +7dB OUT4 +7dB Power Inserter CATV signal input Mounting hole Mounting hole Wall outlet power adapter *Unplug in order to reset. To TV or cable converter Insert ground wire DO NOT CONNECT Hand-tighten only To TVs or cable converters EDA 2400 PWR 15 VDC 270 mA 5 - 42 54 - 1000 MHz 6 kV Insert ground wire CATV signal input Mounting hole RF OUTPUTS TM PWR 15 VDC EDA-FT08000 5-42 54-1000 MHz 6 kV PWR RF IN PWR REV LOSS 10 dB FWD GAIN 3 dB PWR LED REMOTE (TOP) Wall outlet power adapter *Unplug in order to reset. Hand- tighten only Power Inserter To TV or cable converter RF TV 5-1000 MHz RF-PWR TO AMP PWR IN DO NOT CONNECT Mounting hole To TVs or cable converters For warranty, repair or return information, visit our Web site at www.electroline.com EDA-FT Series EDA and ERA Series EDA-FT Series EDA and ERA Series

Upload: lamngoc

Post on 22-Mar-2018

227 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: DROPAmpTM Installation Instructions - Drop Amp » …dropamp.com/assets/images/install/Installation_Instruction_Bil.pdf · DROPAmpTM Installation Instructions Important Safety Instructions

305-0076 Ver.1 Copyright © 2001-2003 Electroline Equipment Inc., 8265 St-Michel Blvd., Montréal, Québec H1Z 3E4 Tel. 800-461-3344 or (514) 374-6335 Fax (514) 374-2257 [email protected]

.

DROPAmpTM

Installation Instructions

Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Do not use this apparatus near water. Clean only with a dry cloth. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The above instructions and warning apply only to the wall adapter.

Materials supplied • Electroline DROPAmp EDA-FT, EDA or ERA series • Wall adapter, 120 VAC, 15 VDC (or 120 VAC, 18 VDC for

two-way or return path models) • Electroline Power Inserter model EDA-IC-F (optional)

Materials not supplied • 1” screws (#6) of an appropriate type for the mounting surface • nylon screw anchors (3/16” x 1”) • coaxial cables with male F-type connectors • grounding wire (#6–#14 gauge)

Installation 1. With two 1” #6 screws, mount the DROPAmp on a wood, drywall,

brick or cement surface. Use nylon screw anchors on all mounting surfaces other than wood.

2. To ground the DROPAmp, insert #6–#14 gauge grounding wire in the hole at the top left edge of the DROPAmp. Tighten the seizure screw with a #2 Phillips head screwdriver.

3. Connect the CATV drop cable to the DROPAmp’s RF IN connector. 4. Follow the Local Powering (A) or Remote Powering (B) instructions.

A. For Local Powering A1. Connect the subscriber’s TV set(s) or cable converter(s) to the

output(s) on the DROPAmp. Note that the ERA 4100 is normally used to connect a cable modem or interactive set-top box. Install 75-ohm terminators on any unused outputs.

A2. Use coaxial cable with a male F-type connector at each end to connect the wall adapter to the DROPAmp’s PWR connector. The wall adapter’s F connector should be hand-tightened only. The maximum recommended length for the cable is 100 feet (30 meters), or 57 feet (17 meters) for the ERA 4100 model.

Figure A: Example of Local Powering

TM

EDA 2400PWR 15 VDC 270 mA5 - 42 54 - 1000 MHz 6 kV

Wall outlet poweradapter*Unplug in orderto reset.

Insert ground wire

To TVs or cableconverters

CATV signalinput

Mountinghole

Mountinghole

Hand-tightenonly

OUT2+7dB

OUT3+7dB

OUT4+7dB

OUT1+PWR+7dB

Insert ground wire

To TVs or cableconverters

CATV signal input

Mountinghole

RF OUTPUTS

TM PWR 15 VDC

EDA-FT080005 - 42 5 4 -1000 MHz 6 kV

PWR RF INPWRREV LOSS 10 dBFWD GAIN 3 dB

PWR

LED

REMOTE(TOP)

Wall outlet poweradapter

*Unplug in orderto reset.

Hand-tightenonly

Mountinghole

Troubleshooting: If the DROPAmp is not working (power LED is off or dim, or output signal is not amplified), check for a short circuit on the coaxial cable between the DROPAmp and the wall adapter. Repair the short circuit, and then reset the wall adapter as follows: • Unplug the wall adapter from the power source, and wait 20 seconds.

This resets the overload protection device (PTC), where applicable. • Plug the wall adapter back into the power source. The DROPAmp’s

green power LED should now be lit brightly. If the LED is dim, repeat the reset procedure. If problems persist, contact Electroline’s technical support department.

B. For Remote Powering B1. With one 1” #6 screw, mount the Power Inserter on a wood,

drywall, brick or cement surface. Use a nylon screw anchor onall mounting surfaces other than wood.

B2. Run a coaxial cable from the RF TV connector on the PowerInserter to the subscriber’s TV set or cable converter. Note thatthe ERA 4100 model is normally connected to a cable modem orinteractive set-top box.

B3. Connect one end of the subscriber’s additional TV sets or cableconverters to the remaining outputs on the DROPAmp. Install75-ohm terminators on any unused outputs. On all models, do notconnect anything to the PWR port.

B4. Use coaxial cable with male F-type connectors at each end toconnect the Power Inserter’s RF-PWR TO AMP connector to theDROPAmp’s remote power output (REMOTE PWR or OUT1).

B5. Use coaxial cable with male F-type connectors at each end toconnect the wall adapter to the Power Inserter’s PWR INconnector. The wall adapter’s F connector should be hand-tightened only. The maximum recommended length for thecoaxial cables from the wall outlet to the DROPAmp is 100 feet(30 meters), or 21 feet (6 meters) for the ERA 4100 model.

5. Plug the wall adapter into an indoor power outlet. If properlyconnected, the DROPAmp’s green power LED will be lit.

Figure B: Example of Remote Powering

RF TV5-1000MHz

RF-PWRTO

AMPPWR

IN

TM

OUT1+PWR+7dB

OUT2+7dB

OUT3+7dB

OUT4+7dB

Power Inserter

CATV signalinput

Mountinghole

Mountinghole

Wall outletpower adapter*Unplug in orderto reset.

To TV or cableconverter

Insert ground wire

DO NOTCONNECT Hand-tighten only

To TVs or cable converters

EDA 2400PWR 15 VDC 270 mA5 - 42 54 - 1000 MHz 6 kV

Insert ground wire

CATV signal input

Mountinghole

RF OUTPUTS

TM PWR 15 VDC

EDA-FT080005 - 42 5 4 -1000 MHz 6 kV

PWR RF INPWRREV LOSS 10 dBFWD GAIN 3 dB

PWR

LED

REMOTE(TOP)

Wall outlet poweradapter*Unplug in orderto reset.

Hand-tighten

only

Power Inserter

To TV or cableconverter

RF TV5-1000MHz

RF-PWRTO

AMPPWR

IN

DO NOTCONNECT

Mountinghole

To TVs or cableconverters

For warranty, repair or return information, visit our Web site at www.electroline.com

EDA-FT Series

EDA and ERA Series

EDA-FT Series

EDA and ERA Series

Page 2: DROPAmpTM Installation Instructions - Drop Amp » …dropamp.com/assets/images/install/Installation_Instruction_Bil.pdf · DROPAmpTM Installation Instructions Important Safety Instructions

305-0076 Ver.1 Copyright © 2001-2003 Electroline Equipment Inc., 8265 St-Michel Blvd., Montréal, Québec H1Z 3E4 Tel. 800-461-3344 or (514) 374-6335 Fax (514) 374-2257 [email protected]

DROPAmpMC

Notice d’installation Instructions de sécurité importantes Lire ces instructions. Garder ces instructions. Prendre en considération tous les avertissements. Ne pas utiliser l’appareil à proximité de l’eau. Nettoyer seulement avec un linge sec. Utiliser seulement les accessoires recommandés par le fabricant. Débrancher l’appareil durant les orages électriques et quand l’appareil n’est pas utilisé pour une période prolongée. Tout entretien doit être fait par des personnes qualifiées. Voir à l’entretien de l’appareil si, par exemple, le cordon ou la prise d’alimentation est endommagé, si du liquide s’infiltre dans l’appareil ou des objets s’y glissent, si l’appareil est exposé à la pluie ou à l’humidité, si l’appareil ne fonctionne pas correctement ou si on l’a laissé tomber. AVERTISSEMENT: Pour réduire les risques de feu ou de choc électrique, ne pas exposer l’appareil à l’eau ou à l’humidité. Les instructions et l’avertissement ci-haut ne s’appliquent qu’à l’adaptateur d’alimentation.

Matériel fourni • DROPAmp Electroline de la série EDA-FT, EDA ou ERA • adaptateur d’alimentation 120 VCA, 15 VCC (ou 120 VCA, 18 VCC pour

les modèles bidirectionnels ou de voie de retour) • injecteur d’alimentation Electroline, modèle EDA-IC-F (optionnel)

Matériel non fourni • vis de montage (#6) de type approprié pour la surface de fixation • chevilles d’ancrage de vis, en plastique (3/16 pouce x 1 pouce) • câbles coaxiaux avec connecteurs mâles de type F • fil de mise à la terre (calibre #6-#14)

Installation 1. À l’aide de deux vis #6 de 1 pouce, fixer le DROPAmp sur une surface en

bois, en gypse, en brique ou en ciment. Utiliser les chevilles en plastique pour toute surface de fixation sauf celles en bois.

2. Pour mettre le DROPAmp à la terre, insérer un fil de mise à la terre de calibre #6-#14 dans le trou situé sur le côté supérieur gauche du DROPAmp. Resserrer la vis de retenue au moyen d’un tournevis à pointe cruciforme #2.

3. Brancher le câble du réseau CATV au connecteur RF IN du DROPAmp. 4. Suivre les indications pour effectuer le branchement d’alimentation

locale (A) ou à distance (B). A. Alimentation locale

A1. Relier la ou les sorties du DROPAmp au(x) téléviseur(s) ou au(x) câblosélecteur(s) de l’abonné. Noter que le modèle ERA 4100 s’emploie dans le but de brancher un modem câble ou un câblosélecteur interactif. Placer une terminaison de 75 ohms sur toutes les sorties non utilisées.

A2. Pour relier l’adaptateur d’alimentation au connecteur PWR du DROPAmp, utiliser un câble coaxial muni de deux connecteurs mâles de type F. Sur l’adaptateur d’alimentation, serrer le connecteur F à la main seulement. La longueur du câble ne doit pas être supérieure à 30 m (100 pi) ou 17 m (57 pi) s’il s’agit du modèle ERA 4100.

Figure A : Exemple de branchement pour l’alimentation locale

TM

EDA 2400PWR 15 VDC 270 mA5 - 42 54 - 1000 MHz 6 kV

Adaptateurd'alimentation*Débrancher afin deréinitialiser.

Insérer fil de mise à la terre

Vers téléviseurs oucâblosélecteurs

Entrée du signaldu câble

Trou demontage

Trou demontage

Serrer à lamain

OUT2+7dB

OUT3+7dB

OUT4+7dB

OUT1+PWR+7dB

Insérer fil de mise à la terre

Vers téléviseurs oucâblosélecteurs

Entrée du signaldu câble

Trou demontage

RF OUTPUTS

TM PWR 15 VDC

EDA-FT080005 - 42 5 4 -1000 MHz 6 kV

PWR RF INPWRREV LOSS 10 dBFWD GAIN 3 dB

PWR

LED

REMOTE(TOP)

Adaptateurd'alimentation

*Débrancher afinde réinitialiser.

Serrer à la main

Trou demontage

Instructions de dépannage : Si le DROPAmp ne fonctionne pas (la DEL est éteinte ou faible ou le signal de sortie n'est pas amplifié), vérifier s’il y a un court circuit sur le câble coaxial entre l’adaptateur et le DROPAmp. Éliminer le court circuit, puis réinitialiser l’adaptateur d’alimentation : • Débrancher l'adaptateur de la prise de courant, et attendre 20 secondes.

Ceci remet à l'état initial le dispositif de protection de surcharge (circuit PTC), lorsque applicable.

• Rebrancher l’adaptateur dans la prise de courant. La DEL verte du DROPAmp est maintenant allumée à pleine intensité. Si la DEL est faible, répéter la procédure de réinitialisation. Si les problèmes persistent, communiquer avec le service de soutien technique d’Electroline.

B. Alimentation à distance B1. À l’aide d’une vis #6 de 1 pouce, fixer l’injecteur d’alimentation sur

une surface en bois, en gypse, en brique ou en ciment. Utiliser unecheville en plastique pour toute surface sauf celles en bois.

B2. Relier par un câble coaxial le connecteur RF TV de l’injecteurd’alimentation au téléviseur ou au câblosélecteur de l’abonné. Noterque le modèle ERA 4100 s’emploie dans le but de brancher un modemcâble ou un câblosélecteur interactif.

B3. Au besoin, relier les sorties du DROPAmp aux téléviseurs ou auxcâblosélecteurs additionnels de l’abonné. Placer une terminaison de 75ohms sur toutes les sorties non utilisées. Ne rien brancher sur leconnecteur PWR.

B4. Relier, par un câble coaxial muni de deux connecteurs mâles detype F, le connecteur RF-PWR TO AMP sur l’injecteur d’alimentation auport REMOTE PWR ou OUT1 sur le DROPAmp.

B5. Relier, par un câble coaxial muni de deux connecteurs mâles detype F, l’adaptateur d’alimentation au connecteur PWR IN surl’injecteur d’alimentation. Sur l’adaptateur d’alimentation, serrer leconnecteur F à la main seulement. La longueur totale des câblescoaxiaux reliant la prise murale au DROPAmp ne doit pas êtresupérieure à 30 m (100 pi) ou 6 m (21 pi) s’il s’agit du ERA 4100.

5. Brancher l’adaptateur d’alimentation dans une prise de courantintérieure. Si le DROPAmp est bien branché, la DEL verte s’allumera.

Figure B : Exemple de branchement pour l’alimentation à distance

RF TV5-1000

MHz

RF-PWRTO

AMPPWR

IN

TM

OUT1+PWR+7dB

OUT2+7dB

OUT3+7dB

OUT4+7dB

Injecteurd'alimentationTrou de

montageTrou demontage

Vers téléviseurou câblosélecteur

NE RIENBRANCHER

EDA 2400PWR 15 VDC 270 mA5 - 42 54 - 1000 MHz 6 kV

Adaptateurd'alimentation*Débrancher afinde réinitialiser.

Serrer à la main

Entrée dusignal du câble

Insérer fil de miseà la terre

Vers téléviseurs ou câblosélecteurs

Trou demontage

RF OUTPUTS

TM PWR 15 VDC

EDA-FT080005 - 42 5 4 -1000 MHz 6 kV

PWR RF INPWRREV LOSS 10 dBFWD GAIN 3 dB

PWR

LED

REMOTE(TOP)

Verstéléviseur/

câblosélecteur

RF TV5-1000

MHz

RF-PWRTO

AMPPWR

IN

Trou demontage

Adaptateurd'alimentation*Débrancher afin deréinitialiser.

Insérer fil de mise à la terre

Serrer à lamain

Injecteurd'alimentation

NE RIENBRANCHER

Vers téléviseursou câblosélecteurs

Entrée du signaldu câble

Pour toute information concernant la garantie, les réparations ou la politique de retour, visiter le site Web d’Electroline au

www.electroline.com

Série EDA-FT

Série EDA et ERA

Série EDA-FT

Série EDA et ERA