dwyer's digital manometers
TRANSCRIPT
![Page 1: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/1.jpg)
Dwyer’s Handheld Digital Manometers
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the
Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2015 Dwyer Instruments, Inc.
![Page 2: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/2.jpg)
Outline• Across the Board Features• Manometer Selling Features and Competition– 476A Single Pressure Manometer– 478A, 475, 490A, 477B, 477AV differential
pressure manometers• Applications• Questions
![Page 3: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/3.jpg)
Introduction
• Wide Selection – Single Pressure – Differential Pressure – Air & Gas Measurement – Wet/Wet Measurement– High Accuracy
![Page 4: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/4.jpg)
Across the Board Features
• 9 Volt Battery Powered – Up to 100 Hours of Use
• Extruded Aluminum Case • Ultra-fine Resolution on Low Ranges • Selectable Units of Measure• Includes Wrist Strap• Instructions Printed on Device• Carrying Cases, Air Flow Kits and More Available
![Page 5: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/5.jpg)
476A & 478A Manometers
• Push Button Auto-Zero• ±1.5% FS Accuracy • Low Cost Design• 476A: Single Pressure – -20 to 20 in w.c.
• 478A: Differential Pressure– -4 to 4 in w.c. – -60 to 60 in w.c.
![Page 6: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/6.jpg)
475 Digital Manometer
• Vast Array of Ranges (11 total)– Lowest Range: 0-1 in w.c. – Highest Range: 0-150 psi
• ±0.5% FS accuracy • Measures positive, negative & differential pressures• Air and compatible combustible gases– Can be used for natural gases
![Page 7: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/7.jpg)
490A Hydronic Digital Manometer
• Liquid & Gas Pressure • 316L SS Wetted Materials• ±0.5% FS Accuracy • Memory Function (stores 40 readings)• Audible & Visual Overpressure Alarms• Adjustable Dampening Rate• Optional 3-Valve Manifold Block
![Page 8: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/8.jpg)
477B Digital Manometer
• Measure Positive, Negative, or Differential Pressure
• Accuracy: 0.1% Full Scale• Stores up to 40 Readings • Audible and Visual Alarms• Backlit Display • Perfect for laboratory readings and checking
calibration of other instruments
![Page 9: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/9.jpg)
477AV Digital Manometer
• Pressure, Velocity, and Flow Measurements– Programmable Duct Sizes – Useful with Pitot Tubes
• Measures Positive, Negative, & Differential Pressure• Backlit Display• Up to 40 stored readings
The Traverse Tool!
![Page 10: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/10.jpg)
Manometer Accessories
• A-402A Carrying case– Snaps on belt loop for easy carrying
• A-47X-BOOT Manometer Boot– Extra protection for manometer– Magnetic mounting on back
![Page 11: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/11.jpg)
Clean Room Checks
• Verifies that the correct pressure differential exists between the clean room surrounding outside area– Positively Pressurized: in case of leaks,
clean air leaks out instead dirty air and germs leaking in
– Negatively Pressurized: In case of leaks, clean air enters instead of the dirty air and germs leaking out
Dwyer 478A, 475, or 477B
![Page 12: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/12.jpg)
Traverse Readings in Ducts
• Use with pitot tube or flow sensor
• Measure air flow in ducts to ensure proper system performance
• 477AV calculates average velocity and air flow
Dwyer 477AV
![Page 13: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/13.jpg)
Gas Pressure Testing
• Checks natural gas input to furnaces, boilers, and other gas-fired units
• Low pressure creates small, unsafe flame that cannot combust all gas
• High pressure creates large, hot flame that can cause overheating and warping
• Measure post-regulator and make adjustments
Dwyer 475
![Page 14: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/14.jpg)
Filter Pressure Drop
• Measures the Difference Between the Pressure Pre-filter and Post-filter
• Increase in Differential Pressure Indicates Dirty Filter
Dwyer 478A or 475
![Page 15: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/15.jpg)
Balancing Water Loops
• Measuring actual flow compared to design flow to optimize system performance
• Heating and cooling water systems
• Unbalanced water flow in a building causes higher operating costs and comfort issues
Dwyer 490A
![Page 16: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/16.jpg)
Pressure Head Loss
• Energy lost from flowing fluid due to friction– Major loss: pressure lost due to friction in pipes– Minor loss: pressure lost due to tees, bends, valves,
obstructions• Ensures proper flow to all areas of the water
system
Dwyer 490A
![Page 17: Dwyer's Digital Manometers](https://reader034.vdocuments.net/reader034/viewer/2022042610/58a451431a28ab55068b54c3/html5/thumbnails/17.jpg)
Verifying Calibration
• Compare pressure readings of other instruments to highly-accurate 477B to verify they are reading correctly
Dwyer 477B