Document No. 996-156-000-6 Issue 07

device compatibility DX

MORLEY-IAS Dimension Series

Page 2 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

Table of Contents

1 INTRODUCTION ......................................................................................................................... 3 1.1 NOTICE .................................................................................................................................. 3 1.2 SUPPORTED PROTOCOLS........................................................................................................ 3 1.3 SOFTWARE VERSIONS ............................................................................................................ 3

2 SIGNALING LOOP DEVICES .................................................................................................... 5 2.1 APOLLO ................................................................................................................................. 5

2.1.1 Discovery Series ........................................................................................................... 5 2.1.2 Xplorer Series ............................................................................................................... 5 2.1.3 XP95 Series .................................................................................................................. 7 2.1.4 S90 Series..................................................................................................................... 9 2.1.5 Ancillary Devices........................................................................................................... 9

2.2 HOCHIKI ............................................................................................................................... 10 MORLEY-IAS................................................................................................................................... 11 2.3 SYSTEM SENSOR.................................................................................................................. 13

3 SOUNDER CIRCUITS............................................................................................................... 15

4 AUXILIARY SUPPLY OUTPUT................................................................................................ 15

5 PERIPHERAL RS485 CIRCUIT................................................................................................ 16 Table of Tables TABLE 1 - SUPPORTED PROTOCOLS....................................................................................................... 3 TABLE 2 – PANEL < > LOOP DRIVER SOFTWARE VERSIONS .................................................................... 4 TABLE 3 – APOLLO DISCOVERY DEVICES ............................................................................................... 5 TABLE 4 - APOLLO XPLORER DEVICES ................................................................................................... 6 TABLE 5 - APOLLO XP95 DEVICES......................................................................................................... 8 TABLE 6 - APOLLO S90 DEVICES ........................................................................................................... 9 TABLE 7 – APOLLO ANCILLARY DEVICES ................................................................................................ 9 TABLE 8 - HOCHIKI DEVICES................................................................................................................ 10 TABLE 9 – MORLEY-IAS DEVICES........................................................................................................ 12 TABLE 10 – SYSTEM SENSOR DEVICES................................................................................................ 14 TABLE 11 – SOUNDER CIRCUIT COMPATIBILITY INFORMATION ............................................................... 15 TABLE 12 – AUX 24V DC COMPATIBILITY INFORMATION...................................................................... 15 TABLE 13 – PERIPHERAL RS485 CIRCUIT COMPATIBILITY INFORMATION ............................................... 16

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 3 of 18

1 Introduction 1.1 Notice • The material and instructions covered in this manual have been carefully checked for accuracy and are

presumed to be correct. However, the manufacturer assumes no responsibility for inaccuracies and reserves the right to modify and revise this document without notice.

• These instructions cover the device compatibility of the Dimension Series Fire Alarm Control Panels. Refer to the Product Manual (P/N 996-147) for details of how to install, program and maintain the system and to the User Manual (996-148) on how to operate the system.

1.2 Supported Protocols • The DX1, DX2 and DX4 Fire Alarm Control Panels are 1, 2 and 4 loop panels for use with analogue

addressable devices from the following detector manufacturer ranges: -

S90

Table 1 - Supported Protocols

1.3 Software Versions • This manual also covers compatibility issues for the on-board sounder outputs, auxiliary supply outputs

and for the peripheral RS845 circuit.

• The Version of the Panel Operating Software at which devices are supported is listed in each table against each individual device. The quoted version number identifies the software version at which the functionality to support the device was incorporated or was the software version at which the device was validated as compatible. Morley-IAS Fire Systems does not warrant that the devices are compatible with panels at software versions earlier than those quoted.

• The Software part numbers are as follows: DX1 – SW993-667 DX2 – SW993-668 DX4 – SW993-668

Panel Software Versions

Software Part Numbers

MORLEY-IAS Dimension Series

Page 4 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

• The Panel Operating Software also includes the loop driver software for each protocol. The following table details the versions of loop driver software embedded in the panel operating software.

Panel Software Version

Apollo Hochiki System Sensor

Morley-IAS

1.00 4.00 3.00 7.02 7.02

1.01 4.00 3.00 7.02 7.02

1.02 5.00 3.00 7.02 7.02

1.03 5.00 3.00 7.02 7.02

1.04 6.00 4.00 7.03 7.03

1.05 6.00 4.01 7.03 7.03

1.06 6.00 4.01 7.03 7.03

1.06c 6.00 4.01 7.03 7.03

2.00 6.01 4.03 7.04 7.04

2.05 6.01 4.03 7.04 7.04

2.07 6.01 4.03 7.04 7.04

Table 2 – Panel < > Loop Driver Software Versions

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 5 of 18

2 Signaling Loop Devices • The 3rd Party Detection Devices and Input / Output Control Modules that can be connected to the

Signaling Line Circuits (SLC LOOPS) are detailed in the following tables.

• NOTE: All of the SLC LOOPS available in the panel must be used with the same device manufacturer products only. (The panel will automatically program the relevant protocol operating software into all of the available loop drivers when selected).

2.1 Apollo

2.1.1 Discovery Series

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

58000-300 Detector – Carbon monoxide -- 3 Band 1 – 5 selectable V2.00 / V2.00

58000-400 Detector – Heat (Fixed) -- 3 Band 1 – 5 selectable V1.00 / V1.00

58000-500 Detector – Ionization Smoke -- 3 Band 1 – 5 selectable V1.00 / V1.00

58000-600 Detector – Optical Smoke -- 3 Band 1 – 5 selectable V1.00 / V1.00

58000-700 Detector – Multi-sensor -- 3 Band 1 – 5 selectable V1.06 / V1.04

Modules:

58000-910 Module – Call Point -- -- Surface mount V1.00 / V1.00

58000-920 Module – Call Point -- -- Flush mount V1.00 / V1.00

Table 3 – Apollo Discovery Devices

2.1.2 Xplorer Series

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

59000-405 Detector – Heat 45 55 Standard Base V1.00 / V1.00

59000-406 Detector – Heat 45 55 LED Drive Base V1.00 / V1.00

59000-407 Detector – Heat 45 55 Ancillary Sounder Base V1.05 / V2.00

59000-415 Detector – Heat – High Temp 45 55 Standard Base V1.00 / V1.00

59000-416 Detector – Heat – High Temp 45 55 LED Drive Base V1.00 / V1.00

59000-417 Detector – Heat – High Temp 45 55 Ancillary Sounder Base V1.05 / V2.00

59000-605 Detector – Optical Smoke 45 55 Standard Base V1.00 / V1.00

59000-606 Detector – Optical Smoke 45 55 LED Drive Base V1.00 / V1.00

59000-607 Detector – Optical Smoke 45 55 Ancillary Sounder Base V1.05 / V2.00

Modules:

59000-810 Module – Output Unit -- -- V1.00 / V1.00

59000-820 Module – Switch monitor -- -- V2.5 / V2.02

MORLEY-IAS Dimension Series

Page 6 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software 59000-910 Module – Call Point -- -- V1.00 / V1.00

Sounders:

59000-407 See Detectors above

59000-417 See Detectors above

59000-607 See Detectors above

45681-275 Base Sounder - - 2.05/ 2.02

Table 4 - Apollo Xplorer Devices

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 7 of 18

2.1.3 XP95 Series

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

55000-265 Detector – Beam 45 55 V1.00 / V1.00

55000-268 Detector – Intelligent Beam (5 – 50 m)

45 55 V1.05 / V1.03

55000-273 Detector – Intelligent Beam (50 – 100 m)

45 55 V1.05 / V1.03

55000-280 Detector – Flame 45 55 V1.00 / V1.00

55000-295 Flameproof Flame Detector 45 55 V2.05/ V2.02

55000-400 Detector – Heat 45 55 V1.00 / V1.00

55000-401 Detector – Heat – High Temp 45 55 V1.00 / V1.00

55000-500 Detector – Ionization Smoke 45 55 V1.00 / V1.00

55000-600 Detector – Optical Smoke 45 55 V1.00 / V1.00

55000-885 Detector – Multi Sensor 45 55 V1.06 / V1.04

Modules:

55000-5881 Module – 3 Channel I/O Unit (inc isolator)

-- -- Fully configurable to support all I/O – as deafult supports 1 input & 1 output.

V2.00 / V2.00

55000-5891 Module – 3 Channel I/O Unit -- -- Fully configurable to support all I/O – as deafult supports 1 input & 1 output.

V2.00 / V2.00

55000-803 Module – Input / Output -- -- DIN V1.00 / V1.00

55000-804 Module – Output -- -- DIN V1.00 / V1.00

55000-807 Module – Switch Monitor Plus -- -- Flush Mount V1.00 / V1.00

55000-808 Module – Switch Monitor -- -- Flush Mount V1.00 / V1.00

55000-809 Module – Switch Monitor Plus -- -- Surface Mount V1.00 / V1.00

55000-810 Module – Switch Monitor -- -- Surface Mount V1.00 / V1.00

55000-812 Module – Zone Monitor + Isolator

-- -- DIN V1.00 / V1.00

55000-813 Module – Zone Monitor -- -- Surface Mount V1.00 / V1.00

55000-816 Module – Input / Output -- -- Flush Mount V1.00 / V1.00

55000-817 Module – Output -- -- Flush Mount V1.00 / V1.00

55000-818 Module – Input / Output -- -- Surface Mount V1.00 / V1.00

55000-819 Module – Output -- -- Surface Mount V1.00 / V1.00

55000-821 Module – Switch Monitor Plus -- -- DIN V1.00 / V1.00

55000-822 Module – Switch Monitor -- -- DIN V1.00 / V1.00

55000-823 Module – Sounder Control -- -- Surface Mount V1.00 / V1.00

55000-824 Module – Sounder Control -- -- Flush Mount V1.00 / V1.00

55000-826 Module – Sounder Control -- -- DIN V1.00 / V1.00

55000-832 Module – Mini Switch Monitor Plus

-- -- V1.00 / V1.00

55000-833 Module – Mini Switch Monitor -- -- V1.00 / V1.00

55000-841 Module – Switch Monitor Plus + Isolator

-- -- V1.00 / V1.00

MORLEY-IAS Dimension Series

Page 8 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software 55000-843 Module – Switch Monitor +

Isolator -- -- V1.00 / V1.00

55000-845 Module – Zone Monitor + Isolator

-- -- V1.00 / V1.00

55000-8471 Module – 3 Way I/O Unit Surface mount.

Fully configurable to support all I/O – as default supports 1 input & 1 output.

V2.00 / V2.00

55000-849 Module – Output Unit -- -- V2.05/ V2.02

55000-852 Module – Sounder Control + Isolator

-- -- Group Addressing feature not supported

V1.00 / V1.00

55000-875 Module – Input / Output (Mains)

-- -- V1.00 / V1.00

55000-905 Module – Call Point -- -- Surface Mount V1.00 / V1.00

55000-906 Module – Call Point -- -- Flush Mount V1.00 / V1.00

55000-940 Module – Call Point -- -- V2.05/ V2.01 r8

Sounders:

45681-261 Sounder Base – 85dB(A) to 92dB(A)

-- -- V1.00 / V1.00

45681-262 Sounder Isolator Base – 85dB(A) to 92dB(A)

-- -- V1.00 / V1.00

45681-265 Intelligent Base Sounder -- -- V2.05/

45681- 277 Base Sounder (inc. isolator) -- -- Group Addressing feature not supported

V2.00 / V2.00

45681- 278 Base Sounder -- -- Group Addressing feature not supported

V2.00 / V2.00

45681- 290 Base Sounder -- -- Group Addressing feature not supported

V2.05/ V2.02

55000-259 Sounder – 85dB(A) White Cap -- -- V1.00 / V1.00

55000-260 Sounder – 85dB(A) Red Cap -- -- V1.00 / V1.00

55000-261 Sounder – 100dB(A) -- -- Group Addressing feature not supported

V1.00 / V1.00

55000-877 Loop Powered Beacon -- -- V1.03 / V1.01

55000-878 Loop Powered Beacon -- -- V2.05/ V1.02

Table 5 - Apollo XP95 Devices

Notes: 1 Devices having more than 1 input and 1 output at the same address are handled as ‘sub-addressed’

devices. Up to 70 such individual inputs or outputs can be configured on each loop.

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 9 of 18

2.1.4 S90 Series

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

54000-601 Detector – Heat 45 55 V1.00 / V1.00

54000-701 Detector – Ionization Smoke 45 55 V1.00 / V1.00

54000-801 Detector – Optical Smoke 45 55 V1.00 / V1.00

Modules: 1

54000-920/2/4/6

Module – Input / Output -- -- Single Input / Output units V1.00 / V1.00

54000-925 Module – Zone Monitor -- -- V1.00 / V1.00

54000-928 Module – Sounder Control -- -- V1.00 / V1.00

54000-901 Module – Call Point -- -- V1.00 / V1.00

54000-902 Module – Call Point -- -- Waterproof V1.00 / V1.00

54000-922 Module – 3 Channel I/O -- -- V2.00 / V2.00

54000-924 Module – 3 Channel I/O (Analogue)

-- -- Analogue input used for fault generation only.

V2.00 / V2.00

54000-927 Module – Call Point -- -- Remote LED output V1.00 / V1.00

Table 6 - Apollo S90 Devices

NOTES: 1 DO NOT combine S90 Modules with DISCOVERY, XP95 or XPLORER modules on the same

installation.

2.1.5 Ancillary Devices

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software 45681-276 Ancillary Base Sounder - - 1. Cannot be auto-

detected by control panel – must set manually (at config tool or control panel)

2. Compatible with all ranges of Apollo sensors except Xplorer/ S90.

3. Cannot be individually disabled.

V1.05 / V1.03

Table 7 – Apollo Ancillary Devices

MORLEY-IAS Dimension Series

Page 10 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

2.2 Hochiki

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

AIC/E-E Detector – Ionization Smoke 45 55 V1.00 / V1.00

ALE/G-E Detector – Optical Smoke 45 55 V1.00 / V1.00

ATD/G-E Detector – Heat 45 55 V1.00 / V1.00

ACA-E Detector – Multi-Sensor 45 55 All 3 modes supported V2.00 / V2.00

ACB-E Detector – Multi-Heat Sensor 45 55 All 12 modes supported. Thresholds fixed in EN54 modes and default to 20/25 in RofR mode.

V2.00 / V2.00

Modules:

CHQ-B1,2 Module – Dual Sounder Control Output

-- -- Full I/O support. Was part supported from (V1.00 / V1.00).

V2.00 / V2.00

CHQ-CP Module – Call Point -- -- V1.00 / V1.00

CHQ-MZ Module – Mini Zone Monitor -- -- Single Input V1.00 / V1.00

CHQ-SIO Module – Input / Output -- -- Single Input / Output V1.00 / V1.00

CHQ-R 1,2 Module – Dual Relay Output -- -- Full I/O support. Part support from (V1.03 / V1.01).

V2.00 / V2.00

CHQ-S 2,3 Module – Dual Switch Monitor -- -- Full I/O support. Part support from (V1.03 / V1.01).

V2.00 / V2.00

CHQ-Z 2,3 Module – Dual Zone Monitor -- -- Full I/O support. Part support from (V1.03 / V1.01).

V2.00 / V2.00

HCP-E Module – Call Point -- -- V2.05 / V2.02

MCP-E/W Module – Call Point -- -- V2.05 / V2.02

YCA-RL/3H2

Addressable Base -- -- For interface to a conventional detector.

V2.00 / V2.00

YCA-RL/5H2

Addressable master base -- -- For interface to conventional detectors.

V2.00 / V2.00

Sounders:

CHQ-AB Loop-powered Beacon -- -- Treat as Sounder (but no tone/ volume settings).

V1.05 / V1.03

CHQ-ARI Addressable Remote Indicator -- -- Has 10 brightness settings. V2.00 / V2.00

CHQ-BS 4 Sounder – Base Sounder -- -- Full base sounder support (auto addressing V1.05).

V1.00 / V1.00

CHQ-WS Sounder – Wall Sounder -- -- V1.00 / V1.00

CHQ-WS2 Sounder – Wall Sounder -- -- Supported in CHQ-WS compatible mode.

V1.00 / V2.02

YBO-BS Sounder – Base Sounder -- -- Supported in CHQ-BS compatible mode.

V1.05 / V2.02

YBO-BSB Sounder – Base Sounder/ Beacon

-- -- Supported in CHQ-BS compatible mode.

V1.05 / V2.02

Table 8 - Hochiki Devices

1 Prior to V2.00 , this device was supported from panel version V1.03 in a limited form. Only the first output was supported. 2 Devices having more than 1 input and 1output at the same address are handled as ‘sub-addressed’ devices. Up to 70 such

individual inputs or outputs can be configured on each loop. 3 Prior to V2.00, this device was supported from panel version V1.03 in a limited form. Only the first input was supported. 4 For panel versions prior to V1.05, set address manually to a value less than 128.

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 11 of 18

Morley-IAS

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

MI-PSE Detector – Optical Smoke 80 100 V1.00 / V1.00

MI-ISE Detector – Ionization Smoke 80 100 V1.00 / V1.00

MI-FHSE Detector – Heat (Fixed) 80 100 V1.00 / V1.00

MI-RHSE Detector – Heat (Rate of Rise) 80 100 V1.00 / V1.00

MI-HTSE Detector – Heat (High Temp) 80 100 V1.00 / V1.00

MI-LPB Detector – Beam 80 100 V1.06 / V1.04

MI-LPB2 Detector – Beam 80 100 V1.06 / V1.04

MI-PTSE Detector – Multi-sensor 3 4 6 modes of operation V2.00 / V2.00

MI-LZR Detector - Laser 4 5 High sensitivity detector with 9 discrete sensitivity settings.

V2.00 / V2.00

Modules:

MI-MCP-FLEX

Module – Manual Call Point -- -- Flexible element V1.00 / V1.00

MI-MCP-FLEX-I

Module – Manual Call Point + isolator

-- -- Flexible element V1.00 / V1.00

MI-MCP-GB Module – Manual Call Point -- -- V1.00 / V1.00

MI-MCP-GB-I

Module – Manual Call Point + isolator

-- -- V1.00 / V1.00

MI-MCP-GLASS

Module – Manual Call Point -- -- Glass element V1.00 / V1.00

MI-MCP-GLASS-I

Module – Manual Call Point + isolator

-- -- Glass element V1.00 / V1.00

MI-MCPW-GB

Module – Manual Call Point -- -- Weatherproof V1.00 / V1.00

MCP5A-RP03 FG-01

Module – Manual Call Point -- -- V2.05 / V2.01

MCP5A-RP04 FG-01

Module – Manual Call Point -- -- V2.05 / V2.01

MI-MM1E Module – Input Monitor -- -- V1.00 / V1.00

MI-MM3E Module – Micro Monitor -- -- V1.00 / V1.00

MI-DMMI Module – Single input -- -- V1.03 / V1.00

MI-CME Module – Output Control -- -- V1.03 / V1.00

MI-CZME Module – Zone Monitor -- -- Surface mount V1.00 / V1.00

MI-DCZM Module – Zone Monitor -- -- V1.00 / V1.00

MI-D240 CMO DIN

Mains DIN Switching Output Module.

-- -- V1.03 / V1.01

MI-D240 CMO

Mains Switching Output Module

-- -- V1.03 / V1.03

MI-D240 CMO-KO

Mains Switching Output Module

-- -- V1.03 / V1.03

MI-DCMO Output Module -- -- V1.03 / V1.03

MORLEY-IAS Dimension Series

Page 12 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software

Sounders:

MI-ABS Sounder – Loop external power

-- -- V1.00 / V1.00

MI-AWSR/ W

Sounder – Loop Powered Wall -- -- Red / White, 85–100dBA V1.00 / V1.00

MI-BEAC Wall Mounted Beacon -- -- V2.05/ V2.02

MI-IBSDB Sounder – Base Sounder -- -- V2.05/ V2.02

MI-IBSD Sounder – Base Sounder -- -- V2.05/ V2.02

MI-IBSE Sounder – Base Sounder -- -- V1.06 / V1.04

MI-LABS Sounder -- -- V1.00 / V1.00

MI-LASR/W Sounder – Loop Sounder -- -- Red / White V1.00 / V1.00

MI--STR Loop Powered Strobe -- -- V1.06 / V1.04

MI-WSDB Sounder – Loop Powered Wall -- -- V2.05/ V2.02

MI-WSD Sounder – Loop Powered Wall -- -- V2.05/ V2.02

Table 9 – Morley-IAS Devices

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 13 of 18

2.3 System Sensor

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software Detectors:

1551E Detector – Ionization Smoke 80 100 V1.00 / V1.00

1251E Detector – Ionization Smoke 80 100 V1.00 / V1.00

2251E Detector – Optical Smoke 80 100 V1.00 / V1.00

2251EIS Detector – I.S. Optical Smoke 80 100 V1.06 / V1.04

2251TEM Detector – Multi-sensor 3 4 6 modes of operation V2.00 / V2.00

2551E Detector – Optical Smoke 80 100 V1.00 / V1.00

5551E Detector – Heat (Fixed) 80 100 V1.00 / V1.00

5551HTE / 5551HTED

Detector – Heat (High Temp) 80 100 V1.00 / V1.00

5551RE Detector – Heat (ROR) 80 100 V1.00 / V1.00

5551REF Detector – Heat (ROR + Fixed)

80 100 V2.05/ V2.02

7251 Detector – Laser 4 5 High sensitivity detector with 9 discrete sensitivity settings.

V2.00 / V2.00

6200 Detector – Beam 80 100 V1.06 / V1.04

6500 Detector – Beam 80 100 V1.06 / V1.04

Modules:

M500MB Module – Input Monitor -- -- V1.00 / V1.00

M500ME Module – Input Monitor -- -- V1.00 / V1.00

M500CHE Module – Output Control -- -- V1.00 / V1.00

M500KAC Module – Call Point -- -- V1.00 / V1.00

M500KACW Module – Call Point -- -- V1.00 / V1.00

M501ME Module – Mini-Input-Monitor -- -- V1.00 / V1.00

M502M Module – Interface Module. -- -- V1.00 / V1.01

M503ME Module – Micro Input Monitor -- -- V1.00 / V1.00

M512ME Module – Zone Input Monitor -- -- V1.00 / V1.00

M201E Module – Output Module -- -- V1.03 / V1.01

M201E-240 DIN

Module – Mains DIN Switching Output Module.

-- -- V1.03 / V1.01

M201E-240/ -KO

Module – Mains Switching Output Module

-- -- V1.03 / V1.01

M210E Module – Single Input -- -- V1.00 / V1.00

M210E-CZ Module – Zone Input Monitor -- -- V1.06 / V1.04

MCP5A-RP01FF-01

Module – Call Point -- -- Flexible element V1.06 / V1.04

MCP5A-RP01FG-01

Module – Call Point -- -- Glass element V1.06 / V1.04

MCP5A-RP02FF-01

Module – Call Point -- -- Flexible element V1.06 / V1.04

MCP5A-RP02FG 01

Module – Call Point -- -- Glass element V1.06 / V1.04

MORLEY-IAS Dimension Series

Page 14 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

Model Device Type Pre-Alarm

Fire Point

Comments Panel/ Config.

Software RP02FG-01

72221 Module – Isolator -- -- Manufacturer: Pepper & Fuchs V2.05 / V2.01

IST200 Module – Intelligent Translator Module

-- -- Gateway to Intrinsically Safe Area

V2.05 / V2.01

Sounders:

DBS24Axx Sounder – Base Sounder -- -- Loop Powered V1.00 / V1.00

EMA24Aex Sounder – Loop Sounder -- -- Externally Powered V1.00 / V1.00

EMA24Alx Sounder – Loop Sounder -- -- Loop Powered V1.00 / V1.00

IBSOU-xx Sounder – Base Sounder -- -- Loop Powered V2.05/ V2.02

IBSST-WR-P02

Sounder – Integrated Detector Base Loop Sounder/Strobe

-- -- Loop Powered, ISO V2.05 / V2.01

WMSOU-RR-P01

Sounder – Wall Mounted Loop Sounder

-- -- Loop Powered V2.05 / V2.01

WMSST-WR-P01

Sounder – Wall Mounted Loop Sounder/Strobe

-- -- Loop Powered V2.05 / V2.01

Table 10 – System Sensor Devices

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 15 of 18

3 Sounder Circuits

Circuit Description Minimum Voltage1

Maximum Current3

Comments Panel Software

SNDR #1 Sounder (NAC) Output

18V DC

(15.5V Abs min)2

1.0A 6.8KΩ EOL Resistor -

SNDR #2 Sounder (NAC) Output

18V DC

(15.5V Abs min)2

1.0A 6.8KΩ EOL Resistor -

Table 11 – Sounder Circuit Compatibility Information

NOTES: 1 Minimum Output voltage is specified at Battery Minimum (21V DC) 2 At minimum AC Mains voltage (230V – 15%), under full-load and with the battery terminals shorted. 3 Maximum current is the maximum current allowed per circuit. Each circuit is fused at 1.1 amperes.

Refer to the Product Manual for details of maximum allowed external load. Maximum permitted load current is quoted at 25°C ambient – reduce load to 82% of quoted figure at 40°C – reduce load to 77% of quoted figure at 49°C. Maximum permitted surge current is 2.0 amperes per circuit – take account, when installing strobes, etc., of the surge current for these devices.

4 Ensure that the sounders / bells installed can operate at the minimum voltage including any voltage drops induced in the cable run.

4 Auxiliary Supply Output

Circuit Description Minimum Voltage1

Maximum Current3

Comments Panel Software

AUX Auxiliary Supply – Nominal 24V DC

18V DC

(15.5V Abs min)2

0.25A -

AUX – SW Auxiliary Supply (Switched) – Nominal 24V DC

18V DC

(15.5V Abs min)2

0.25A The switched auxiliary output is turned off for five seconds when the panel is reset

-

Table 12 – AUX 24V DC Compatibility Information

NOTES: 1 Minimum Output voltage at Battery Minimum (21V DC) 2 At minimum AC Mains voltage (230V – 15%), under full-load and with the battery terminals shorted. 3 Maximum current is the maximum current allowed per circuit and for both circuits simultaneously (i.e.

total AUX power available is 0.25A). Each circuit is fused at 0.25 amperes. Maximum current is quoted at 25°C ambient – reduce load to 80% of quoted figure at 40°C – reduce load to 72% of quoted figure at 49°C.

4 Ensure that any devices powered from the auxiliary supply can operate at the minimum voltage including any voltage drops induced in the cable run.

MORLEY-IAS Dimension Series

Page 16 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility

5 Peripheral RS485 Circuit • The devices that can be connected to the RS485 Peripheral Circuit are listed in the table below:

Model Device Type Address1 Comments Panel Software

ZXr-A Repeater -Active 1 – 16 V1.00

ZXr-P Repeater - Passive 0 – 16 Address ‘0’ is unsupervised at the control panel

V1.00

Table 13 – Peripheral RS485 Circuit Compatibility Information

NOTES: 1 Maximum of sixteen (16) addressed repeaters in total.

Dimension Series MORLEY-IAS

Device Compatibility Document No. 996-156-000-6, Revision: 06 Page 17 of 18

NOTES

MORLEY-IAS Dimension Series

Page 18 of 18 Document No. 996-156-000-7, Revision: 07 Device Compatibility