eco cfl flood light with motion sensor · of darkness each evening. observe the operation of the...
TRANSCRIPT
![Page 1: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/1.jpg)
ECO CFL Flood Lightwith Motion Sensor
Model: ECO1PIRModel: ECO2PIRModel: ECO3PIR
Ins
talla
tion
& O
pe
ratin
g In
stru
ctio
ns
![Page 2: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/2.jpg)
1
Ø6mm
35mm
60mm
140º PIR detector (pan only) within adjustable 180º range and 10m detection.
Movement140°
90°
10m 10m
1.8m
Top View Side View
Movement140°
90°
10m 10m
1.8m
Top View Side ViewSide ViewTop View
1.8m
Movement
10m10m
![Page 3: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/3.jpg)
2Slaving
For ECO CFL Flood Light Uncontrolled Unit only
For ECO1PIR & ECO2PIR only
23W Max
![Page 4: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/4.jpg)
3
For ECO1PIR & ECO2PIR only
Test mode
3 minutes
3 minutes 3 minutes15 minutes
Tilt 60º
Pan 30º 2
1
For ECO3PIR only
23W Max
![Page 5: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/5.jpg)
4
2 second
x2
Dusk
Dawn
24Hrs
Setting at day time,Operate at night time.
Normal ride modeonly operate
1 night after that willback to Auto Mode.
Lamp turns ON at night
Lamp turns ON at day & night
A
B
![Page 6: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/6.jpg)
5
1. General InformationThe unit utilises passive infrared technology to detect heat radiation of moving human bodies.
Upon detection, the lamp will illuminate for a user-determined time period.
An integral daylight sensor ensures night-only operation if required.
2. Parts Included• LowEnergyFloodlightc/wmotionsensor.• Instructionmanual.Pleasekeepsafeforfuturereference.• AccessoryPackincludinglensmask,screwsandwallplugs.• 1pc.20WlowenergyCompactFluorescentLight.(ForECO1PIR&ECO3PIR)• 2pcs20WlowenergyCompactFluorescentLight.(ForECO2PIR)
3. Tools & Parts Needed• 3flexiblecorecable(1.0mm²or1.5mm²).
• Electric/hand-helddrill&bits.
• TerminalorElectriciansscrewdriver.
• Wirecutters.
Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or on medication with similar side effects.
No User Serviceable Parts Inside
![Page 7: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/7.jpg)
6
IMPORTANTSwitch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with
the installation (Diagram 2).
4. Installation
After choosing a suitable location install the unit as follows:
Theunitissuitableforconnectionto230Vac50Hzelectricitysupply.Itissuggestedthat3-coreroundflexiblecableof1mm²or1.5mm²gaugeisused. An internal switch should be installed to switch the power to the unit .
This allows the unit to be easily switched off when not required or for maintenance purposes.
Thisunitusesanintegralwallfixingplate,detachthewallfixingplatebyunscrewingandreleasebutdonotremovethefixingscrewontheundersideofthewallplate(Diagram3).
Markthepositionofthewallfixingholes(60mm).Ensurethewallplateiscorrectlypositioned.Notethe“TOP”identontheinsideofthewallplate.Drilltheholes,insert the wall plate into the holes.
Pierceandpassthecablethroughthegrommetbeforesecuringthewallplatetothe wall.
Itisrecommendedthatthegrommetispiercedwithascrewdrivertoensureabetterseal.(Diagram4).
Fixthewallplatetothewallwithscrewsprovided.Connectthecabletotheterminalblockontheunitasfollows(Diagram5):
Neutral (Blue ) N
EARTH (Green/ Yellow)
LIVE (Brown) L’
EnsureConnectionsaresecure.
Theunitissuppliedwithahangingattachment(tether)toaidinstallation.Ensurethetetherissecurelyfixedintotheslotbeforereleasingtheweightoftheunit. (Diagram6)
![Page 8: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/8.jpg)
7
Designed in the U.K. 67-058-424
Timeguard Limited. Victory Park, 400 Edgware Road,
London NW2 6ND Sales Office: 020 8452 1112
or email [email protected]
or email [email protected]
5. Operation and TestingSetting Up For Automatic Operation
The Sensor Head can be panned 90 degree to left and 90 degree to the right. (Diagram 10)
Theadjustmentcontrolsontheunit(Diagram11)shouldbesetasfollows.
TheTIMEcontroldetermineshowlongthelampremainsilluminatedafteractivation(3minto15min).
These settings allow the lamp to illuminate for the designated time on period after darknessfallsandtheunitisactivated.
Toconnectanotherunitofuncontrolledfloodlight,connecttheloopingpowercabletotheterminalblockonthemasterunitasfollows(Diagram7):
Neutral (Blue ) N
EARTH (Green/ Yellow)
LIVE (Brown) L’
Fitthefloodlighttothebracketbyinsertingthecatchinthefloodlightintotherecessatthetopofthewallplateandlocatingthefloodlightsecurelyoverthewallplate.Fitandfullysecuretheretainingscrew(Diagram3).
For ECO1PIR & ECO2PIR
TofittheCFL,releasebutdonotremovethescrewonthefrontcoverofthefloodlight,openandrotatedownbutdonotseparatefromthemainfloodlightbody.(Diagram8)
For ECO3PIR
Tofitthebulb,turnthelampenclosure180anti-clockwisetoreleasefromthebayonetlock.(Diagram10)
Removethebulbsfromitspackagingandfitintothelampholders.Ensurethebulbis fully secured into the lampholder.
Closethefrontcover,ensurethescrewisfullytighten.
Thisfloodlightusesauniversaljoint,itcanbedirectedtosuityourinstallationbyrotatingthefloodlightlefttorightandupordown.(Diagram9)
![Page 9: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/9.jpg)
8
The DUSK (LUX)controldeterminesthelevelofdarknessrequiredfortheunittostartoperating.(Diagram12)
Walk Test is used to test and adjust the detection coverage of the unit. (Diagram 13)
Adjust the Time knob to “T” then conduct a walk test procedure as described as follows:
• AdjusttheTimeknobto“T”,andLuxknobto“Sun”.
• Walkacrossthedetectionarea,oncethedetectoristriggeredand lamp will On for 3 min.
The setting is best achieved by the procedure below:
SettheDUSKcontrolknobfullyanti-clockwiseandtheTimecontroltotherequiredminutes.
Waituntildarknessfalls.
Whentheambientlightlevelreachesthelevelofdarknessatwhichyouwishthelamptobecomeoperative(ie.Atdusk),SLOWLYrotatethecontrolinaclockwisedirectionuntilapointisreachedwherethelampilluminates.Leavethecontrolsetat this point.
Atthisposition,theunitshouldbecomeoperativeatapproximatelythesamelevelofdarknesseachevening.Observetheoperationoftheunit.Iftheunitisstartingtooperatetooearly(ie.whenitisquitelight),adjustthecontrolslightlyanti-clockwise.Iftheunitstartstooperatetoolate(ie.onlywhenitisverydark),adjustthecontrolslightlyclockwise.
Continuetoadjustuntiltheunitoperatesasdesired.
Lensmaskistomaskoutareanotdesiredfordetection(Diagram15).
Installationoflensmaskasfollows(Diagram16):
• Useapenknifeorplierstocutoutlensmasksegment,exposingareafordetection.
• Attachthelensmasktothedetectorhead.
• Turnslightlythelensmaskforittobelockedintoplace.
Manual Override Mode
The light can be switched on for longer time periods by use of the Manual OverrideMode.
![Page 10: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/10.jpg)
No User Serviceable Parts Inside.
IfyouexperienceproblemsrefertoTroubleshootingGuide. Ifproblemsstillexist,donotimmediatelyreturntheunittostore.
TelephonetheTimeguardCustomerHelpline
020 8450 0515QualifiedCustomerSupportCo-ordinatorswillbeon-line
to assist in resolving your query.
9
6. Technical SpecificationsDetectionRange
Detection Angle
PowerSupply
MaximumExternalLoad
Nootherexternalloads can be used LampType
E27Base TimeOnAdjustment
DuskLevelAdjustment
EnvironmentalProtection
Upto10metres
See figure
230VAC~50Hz
Number of Slave Unit
Master ECO1FL ECO2FL ECO3FL
ECO1PIR 3 1 3
ECO2PIR 2 1 2
ECO3PIR 3 1 3
230AC20WCompactFluorescentlampsupplied
23Wcompactfluorescentmaximum Do not use incandescent or halogen bulbs
20secondsto5minutes
Day&nightornightonlyoperation
IP45(suitableforoutdooruse)
Thiscanbeactivatedatnightbyusingtheinternalwallswitchorcircuitbreaker.
Switchtheinternalwallswitch/circuitbreakertwice(OFF/ON/OFF/ON)within2seconds.Theunitwillnowilluminatecontinuouslyuntildawnoruntilswitchedbackinto Auto Mode.
ToswitchtheunitbackintoAutoMode,switchtheinternalwallswitch/circuitbreakeronce(OFF/ON)withinonesecond.TheunitwillreturntoitsAutoModeandwilloperateassetupafterthewalktestprocedure.(Diagram17).
![Page 11: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/11.jpg)
10
6. Troubleshooting GuideProblemLampstaysONallthetimenight and day.
LampstaysONallthetimeatnight,orPIRkeepsactivatingatrandom for no apparent reason.
PIRkeepsactivatingfornoreason/atrandom.
PIRsensorwillnotoperateatall.LampstaysOFF.
ThePIRsensorwillnotoperate at night.
Unit activates during the daytime.PIRcoverageispoor/sporadic.
Detection range varies fromday to day.
SolutionCheckwiringconnections.WirestoLandL1terminalsmaybe transposed.
Theunitmaybesufferingfromfalseactivation.Coverthesensorlenscompletelywithblackpvctape.Thiswillpreventthesensorfrom"seeing"anything.Iftheunitnowswitchesoff after the set time duration and does not re-activate, this indicates that the problem was caused by false activation. The problem may be solved by slightly adjusting the direction/angleofthesensorhead(seeprevioussection).Ifhowever,theunitcontinuestoremainONortooperaterandomly the unit is faulty and should be replaced.
Youmaynotbeallowingtheunittimetocompleteit'swarm-up period. Stand well out of the detection range and wait(thewarm-upperiodshouldneverexceed5minutes).Occasionally,windsmayactivatethesensor.Sometimespassages between buildings etc. can cause a "wind tunnel" effect.Ensuretheunitisnotpositionedsoastoallowdetectionofcars/peopleusingpublicthoroughfaresadjacenttoyourproperty.Ensurethattheunitismountedsecurely, even the slightest movement can result in a false detection.
CheckthatthepowerisswitchedONatthecircuitbreaker/internalwallswitch.TurnOFFthepowertotheunitandcheckthewiringconnectionsasperthediagram(seesection3).Ensurenoconnectionsareloose.ChecktheCFL.IftheCFLhasfailed,replace.EnsurethattheCFLisseatedcorrectlyinthelampholder.
Refertosection3forDUSKcontroladjustment.
Refertosection3forDUSKcontroladjustment.
Unit may be poorly located.Re-locatetheunit.
PIRsensorsareinfluencedbyclimaticconditions.The colder the ambient temperature, the more effective thesensorwillbe.Youmayneedtomakeseasonaladjustments to the sensor head position to ensuretrouble-free operation all year round.
![Page 12: ECO CFL Flood Light with Motion Sensor · of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust](https://reader034.vdocuments.net/reader034/viewer/2022042021/5e78cbf76b63ff0ecf0f9f11/html5/thumbnails/12.jpg)
Designed in the U.K. 67-058-424
Timeguard Limited. Victory Park, 400 Edgware Road,
London NW2 6NDSales Offi ce: 020 8452 1112
or email [email protected]
For a product brochure please contact:
Zerofour – August 2011
or email [email protected]
HELPLINE020 8450 0515
3 Year GuaranteeIntheunlikelyeventofthisproductbecomingfaultyduetodefectivematerialormanufacturewithin3yearsofthedate of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free ofcharge.Foryears2and3oranydifficultyinthefirstyeartelephonethehelplineon02084500515.
Note: the lamp is not covered by the warranty.
first year with proof of purchase and it will be replaced free