eco icid brochure
DESCRIPTION
ÂTRANSCRIPT
Eco ICID LIT DOC/CP3/63 March 2014
UPDATEDRANGEincludes new
Stove Pipe andAccessories
Eco ICIDTwin Wall Insulated System Chimneydesigned for Stove Applications
Eco ICID LIT DOC/CP3/63 SAP Issue 2 June 2014 Part of the BRAAS MONIER BUILDING GROUP
2
Product DescriptionEco ICID is a Twin Wall Insulated System Chimney designed specifically for use on open or closed stoves with continuous operating temperatures of up to 450°C.
The system is designed so that the outer case is load bearing and the inner liner is free to expand independently, therefore thermal expansion is accommodated within each and every joint of the system.
Available in two versions with a choice of either a bright annealed or a matt black painted stainless steel outer case, Eco ICID is available in the following range of diameters:- 125, 150, 180 and 200mm.
• Manufactured under a Quality Management Scheme approved to BS EN ISO 9001: 2008• 4 Hour Fire Rating to BS476 Part 20• Certified for corrosion resistance on gas, oil and solid fuel by Gastec, MPA and TÜV• HETAS listed for use on solid fuel applications.
Eco ICID is CE Certified to EN1856-1 TÜV 0036 CPD 9195 010 with designations:Eco ICID is CE Certified to EN1856-2 TÜV 0036 CPD 9195 042 with designations:
Approvals
Joint DesignTwist-lock bayonet jointing system. Secured by locking band.
Advanced corrosion resistant design and construction uses laser welded 316L stainless steel inner liner and stainless steel case.
The 25mm of high density rockwool insulation maintains flue gas temperature, maximising efficiency, improving flue draught on start up and minimising condensation.
Low external case temperature.
The inner liner is free to expand through the female collar, allowing for maximum thermal expansion even during a soot fire.
The inner liner has an inward bead at the female end which acts as a capillary break preventing moisture being drawn through the joint.
FuelFiring TempShort Firing TempThermal ShockMode of OperationPressure CapabilitiesFire RatingOuter Case (Standard)Outer Case (Option)Outer Case ThicknessSeamLinerLiner Thickness (mm)SeamInsulationInsulation ThicknessAverage ThermalResistance (200°C)
Wood, solid fuel450° C550° C1000° CZero & negative pressure40Pa4 Hour Fire Rating to BS 476 Part 20Stainless SteelPainted matt black0.5mmLaser or inert gas welded316L : 1.4404 : X2CrNiMo 17-12-20.5mmLaser or inert gas weldedHigh performance mineral fibre25mm0.4m2 k/W
The chimney size should be as recommended by the appliance manufacturer. Where there is a requirement for a flue diameter smaller than the appliance spigot, then the operational requirements of the appliance and the configuration of the flue must satisfy the flue sizing requirements of EN13384-1 for single appliances, and EN13384-2 for multi appliances.
CHIMNEY DIAMETER
CORROSION RESISTANCEChimneys are subject to significant corrosion attack by flue gas condensates, particularly from solid fuel. Eco ICID is specifically designed and manufactured to resist this corrosion.
Tecnical Data
Connecting Flue PipeEN 1856-2
System ChimneyEN 1856-1
T450 N1 W V2 L50050 G60T450 N1 D V3 L50050 G60
60mm Distance to combustiblesin a combustible shaft*
T450 N1 W V2 L50050 G50T450 N1 D V3 L50050 G50
50mm Distance to combustibles in a non combustible shaft or in free air*
T450 N1 D V2 L50050 G100 M
* For full information refer to p.16 and p.17
3
Typical Installations
INTERNAL HOUSECombustible Floors
INTERNAL BUNGALOW(VENTILATED LOFT SPACE)Combustible and Non-Combustible floors
INTERNAL HOUSENon Combustible Floors
EXTERNALSystem Chimney
Raincap (without mesh)
Angled Flashing
Roof Support
Ventilated Firestop Plate
Ventilated Support PlateCombustible floor
Ventilated Firestop PlateCombustible floor Plate
SW-DW Stove Pipe Starter Section
Prima Smooth Connecting Flue Pipe
Combustible shaft
Protective wire mesh(required in loft space)
Taper Terminal
Storm Collar
Uni-flash
Roof Support
Firestop Plate
Support PlateNon combustible floor
Firestop PlateNon combustible floor
Adjustable Pipe
Anchor Plate
Non combustible shaft
Protective wire mesh(required in loft space)
Taper Terminal
Structural Wall Band
Structural Wall Band
Structural Wall Band Extension
45˚ Bend
Adjustable Top Plate
Cantilever Support
135˚ Tee
Mitred Wall Sleeve 45˚
Raincap (with sparkguard)
Angled Flashing
Roof Support
Prima Smooth Connecting Flue Pipe
Protective wire mesh(required in loft space)
Round BungalowFirestop Kit (unventilated)
SW-DW Stove Pipe Starter Section
127
Int Ø
4
DimensionsThe dimensions of the flue are:
FinishPaint - Eco ICID can be supplied painted in any RAL colour (additional costs apply)
(all article codes are for plain stainless steel versions, for black painted codes refer to product ordering paragraph above)Starting Components
Int Ø mmExt Ø mm
125180
150200
180235
200256
A
Int Ø
B
C
A
Int Ø
3530
Int Ø
100
Int Ø
100
Appliance Connector (Open) DN8A047
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125307
125308
150200
126082
126079
180235
126827
126825
200256
127410
COA
Appliance Connector (Closed) DN8A144
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125287
125288
150200
126060
126059
180235
126810
COA
200256
127393
COA
Uninsulated Increasing Adaptor DN8A143
Int ØmmExt Ømm ASAP Code Plain
SAP Code Black
12518098
125320
COA
150200123
125321
125319
180235148 COA
COA
200256178COA
COA
Insulated Increasing Adaptor DN8A136
Int ØmmExt ØmmABCSAP Code Plain
SAP Code Black
125180989849
125305
COA
15020012311352
126077
126078
18023514811352
126824
COA
20025617811352
127408
COA
Adaptor Prima Plus to Eco ICID S027
Int ØmmExt ØmmASAP Code Plain
125180130
125688
150200150
126278
180235180
126967
200256200
127575
Adaptor Prima Smooth to Eco ICID PS027
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
109992
109991
150200
110270
110268
180235
126981
126980
200256
127588
127587
COA : Code on application
127
Int Ø
A
Int ØmmExt ØmmSAP Code Plain
180235
126860
Adaptor Eco ICID to TecnoFlex Plus DN8A079
125180
125354
150200
126132
200256
127443
9042
C Ø
A
B
Anchor Plate DN8A0D6
Int ØmmExt ØmmABCSAP Code Plain
125180300280123
125300
150200320300148
126072
180235355335178
126774
200256375356198
127344
SW-DW Stove Pipe Starter Section1023mm Effective Length DN8A152
Int ØmmExt Ømm ASAP Code Plain
SAP Code Black
125180123
125344
125347
150200148
126124
126125
180235178
126854
126855
200256198
127439
COA
SW-DW Stove Pipe Starter Section473mm Effective Length DN8A149
Int ØmmExt Ømm ASAP Code Plain
SAP Code Black
125180123
125349
125346
150200148
126126
126123
180235- -
-
200256
--
-A Ø
473
40
A Ø
1023
40
5
COA : Code on application
100
A Adaptor Eco ICID to Prima Plus DN8A133
Int ØmmExt ØmmASAP Code Plain
125180130
125292
150200150
126062
180235180
126813
200256200
127396
A Ø
1018
40
A Ø
473
100
SW-DW Adjustable Starter Section DN8A159
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
125180125
125394
125339
150200150
126300
126117
180235180
126989
126849
200256200
127593
127434
Increasing SW-DW Stove Pipe Starter Section DN8A153
Int ØmmExt Ømm ASAP Code Plain
SAP Code Black
125180
--
-
150200123
125345
125348
180235--
-
200256
--
-
Pipes
Eff.
leng
thEf
f. le
ngth
Eff.
leng
thEf
f. le
ngth
Eff.
leng
thEf
f. le
ngth
4040
4040
4040
6
1460mm Effective Length DN8A128
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125253
125251
150200
126019
126017
180235
126780
126778
200256
127350
COA
960mm Effective Length DN8A001
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125285
125286
150200
126058
126056
180235
126808
126809
200256
127392
127388
750mm Effective Length DN8A157
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125273
125274
150200
126045
126046
180235
126797
126798
200256
127380
127379
460mm Effective Length DN8A002
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125269
125270
150200
126039
126037
180235
126793
126794
200256
127376
127372
293mm Effective Length DN8A003
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125261
125262
150200
126030
126028
180235
126786
COA
200256
127362
127358
160mm Effective Length DN8A004
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125258
125259
150200
126025
126023
180235
126784
COA
200256
127357
COA
Eff.
Adj
ustm
ent
Adjustable Pipe 50-230mm 1 Piece - DN8A009
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125298
125294
150200
126071
126064
180235
126819
126815
200256
127402
COA
Eff.
Adj
ustm
ent
Telescopic Pipe 215-310mm 2 Piece - DN8A151
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125295
COA
150200
126066
126068
180235
126816
COA
200256
127399
COA
Telescopic Pipe 350-570mm 2 Piece - DN8A150
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125297
COA
150200
126069
126065
180235
126818
COA
200256
127401
127398
Eff.
Adj
ustm
ent
COA : Code on application
7
Ext Ø
108
Int Ø
A
B
C
D
Supplied as standard with all components with a female collar
Locking Band DN8A083
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125330
125331
150200
126106
126107
180235
126842 COA
200256
127426
COA
Structural Locking Band DN8A092
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
125317
125318
150200
126092
126093
180235
126835
COA
200256
127419
COA
Inspection Length DN8A011
Int ØmmExt ØmmABCDSAP Code Plain
SAP Code Black
12518046095260230
125323
COA
15020046095260230
126099
126097
18023546095260230
126837
COA
20025646095260230
127421
COA
Tees
Int Ø
AB
C
Int Ø
A
B
B
90˚ Tee including Tee Cap DN8A135
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180246127
125282
125283
150200329162
126054
126055
180235354175
126805
COA
200256394195
127387
COA
135˚ Tee including Tee Cap DN8A137
Int ØmmExt ØmmABCSAP Code Plain
SAP Code Black
125180336259259
125249
125250
150200365283283
126015
126016
180235414326326
126777
COA
200256444351351
127347
131796
COA : Code on application
A
Tee Plug with Drain DN8A138
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
12518075
125312
COA
15020077
126088
126089
18023573
126831
COA
20025678
127415
COA
Draught Stabiliser Section DN8A026
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180COA
COA
150200COA
COA
180235
126833
COA
200256
127417
COA
8
A
B
15˚ Bend DN8A018
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
1251806355
125256
125254
1502006356
126022
126020
1802356356
126782
COA
2002566457
127353
COA
30˚ Bend DN8A019
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
1251806657
125264
COA
1502007061
126033
126031
1802357364
126788
COA
2002567768
127366
COA
45˚ Bend DN8A017
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
1251807970
125267
125265
1502008374
126036
126034
1802359182
126791
126789
2002569586
127371
127367
90˚ Bend DN8A015
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180146137
125277
125275
150200156147
126049
126047
180235174165
126800
COA
200256184175
127382
COA
90˚ Inspection Bend DN8A0A2
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180184139
125280
COA
150200194149
126052
COA
180235209164
126803
COA
200256219174
127385
COA
A
B
A
B
A
B
A
B
Bends
COA : Code on application
9
B
A
B
A
Effe
ctive
Pip
e
B
Effe
ctive
Pip
eA
Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe
ABABABABABAB
1251801642408115927995622567615051510638772
1502001644409116127995822567815051710738872
1802351644409116127995822567815051710738872
2002561648409116528096222568215052110739273
15˚ Bend offset with Standard Pipe Length
Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe
ABABABABABAB
12518014947921061542879437628292483208368142
15020015097961076546894441643296498212383146
18023515207991087549905444654299509215394149
20025615358031102553920448669303524219409153
30˚ Bend offset with Standard Pipe Length
A
B
A
B
A
B
Offsets (made by assembling 2 bends)15˚ Offset
Int ØmmExt Ømm AB
12518023231
15020023431
18023523431
20025623831
30˚ Offset
Int ØmmExt ØmmAB
12518023062
15020024466
18023525669
20025627173
45˚ Offset
Int ØmmExt ØmmAB
125180254105
150200268111
180235295122
200256309128
Offsets for 135˚ Tee and 45˚ Bend
Int ØmmExt Ømm AB
125180389310
150200425334
180235497376
200256532402
Typical Offsets (made by assembling 2 bends and a standard pipe section)
10
B
A
Effec
tive P
ipe
Int ØmmExt Ømm1460 Effective Pipe960 Effective Pipe750 Effective Pipe460 Effective Pipe293 Effective Pipe160 Effective Pipe
ABABABABABAB
12518012871138933784785636580431462313367218
15020013001143947790798641593436475318381224
18023513281151974801826653621448503330408235
20025613411160988807839658634453516335422241
45˚ Bend offset with Standard Pipe Length
Firestop Components
BA
BA
Round Ventilated Firestop Plate- Combustible Floor
Int ØmmExt ØABSAP Code Plain
SAP Code Black
SAP Code White
125180183380
126661
126659
126660
150200203400
127227
127225
127226
180235241430
128117
128115
128116
200256259450
128601
128599
128600
1 Piece - 9423*
* Codes and Finish Options Plain Galvanised Steel 9423P0 + Ext Ø Black RAL 9005 Matt 9423B0 + Ext Ø White RAL 9016 Matt 9423W0 + Ext Ø
** One piece firestop available for use exclusively with stove starter pipe
Round Ventilated Firestop Plate- Combustible Floor
Int ØmmExt ØABSAP Code Plain
SAP Code Black
SAP Code White
125180183380
126664
126662
126663
150200203400
127230
127228
127229
180235241430
128120
128118
128119
200256259450
128604
128602
128603
2 Piece - 9424*
* Codes and Finish Options Plain Galvanised Steel 9424P0 + Ext Ø Black RAL 9005 Matt 9424B0 + Ext Ø White RAL 9016 Matt 9424W0 + Ext Ø
Magnetic Firestop Cover Plate Kit 9509
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
SAP Code White
125180183380
126945
126946
126947
150200203400
127552
127553
127554
180235241430
128127
128128
128129
200256259450
128611
128612
128613
BA
Tees (contd.)
11
Bungalow Firestop Kits
BC
A
BC
A
Ventilated Support Plate - Combustible Floor 2 Piece - 95260
Int ØmmExt ØmmABCSAP Code Plain
125180183380190
126667
150200203400200
127234
180235241430215
128124
200256259450225
128607
Rectangular Ventilated Firestop Plate- Combustible Floor 2 Piece - 94250
Int ØmmExt ØmmABCSAP Code Plain
125180183380190
126666
150200203400200
127232
180235241430215
128122
200256259450225
128606
B
A
A
AB
Firestop Plate- Non Combustible Floor 94670
Int ØmmExt ØmmABSAP Code Plain
125180450280
126624
150200450300
127200
180235450338
128099
200256610356
128584
Support Plate- Non Combustible Floor 95680
Int ØmmExt ØmmABSAP Code Plain
125180330280
126646
150200350300
127210
180235450338
128107
200256406356
128591
Bungalow Round Firestop Plate- Unventilated
Int ØmmExt ØABSAP Code Plain
SAP Code Black
SAP Code White
125180183380
126526
126528
126529
150200203400
127108
127110
127111
180235241430
128084
128086
128087
200256259450
128571
128572
128573
1 Piece - 9428*
* Codes and Finish OptionsPlain Galvanised Steel 9428P0 + Ext ØBlack Ral 9005 Matt 9428B0 + Ext ØWhite Ral 9016 Matt 9428W0 + Ext Ø
B
A
Bungalow Firestop Kits (contd.)
B
A
B
A
12
These unventilated fire stop plates may only be used on a combustible ceiling in a bungalow where there is a minimum 60mm distance to combustibles where the chimney penetrates the ceiling area and where the roof space above the ceiling is open and ventilated. Within the roof space, a protective wire mesh framework must be built around the chimney to ensure the minimum 60mm distance to combustibles is maintained.
* Codes and Finish OptionsPlain Galvanised Steel 9430P0 + Ext ØBlack Ral 9005 Matt 9430B0 + Ext ØWhite Ral 9016 Matt 9430W0 + Ext Ø
Bungalow Square Firestop Plate- Unventilated 1 Piece - 9430*
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
SAP Code Black
125180183380
127015
127016
COA
150200203400
127619
127620
COA
180235241430COA
COA
COA
200256259450COA
COA
128614
BD C
E
A
Top Plate DN8A0D3
Int ØmmExt ØmmABCDESAP Code Plain
SAP Code Black
125180276280240160140
125140
COA
150200296300260180150
125833
125834
180235334335298210168
126572
COA
200256352356316230178
127151
COA
Wall Support Side Plates DN8A0D2
Int ØmmExt ØmmBCDESAP Code Plain
SAP Code Black
125180275160470100
125357
125355
150200295180470100
126136
126133
180235325210470100
126862
COA
200256345230470100
127445
COA
B
D
C
E
Bungalow Round Firestop Plate- Unventilated
Int ØmmExt ØABSAP Code Plain
SAP Code Black
SAP Code White
125180183380
126527
131122
COA
150200203400
127109
127106
127107
180235241430
128085
COA
COA
200256259450
131123
COA
COA
2 Piece - 9429*
* Codes and Finish OptionsPlain Galvanised Steel 9429P0 + Ext ØBlack Ral 9005 Matt 9429B0 + Ext ØWhite Ral 9016 Matt 9429W0 + Ext Ø
Support Components
COA : Code on application
13
Cantilever Support
Type 325 - 95420001Type 475 - 95420002
TypeInt Ømm RangeABSAP Code Plain
SAP Code Black
325125 - 150
325242
101742
130686
475125 - 200
475242
101743
130687
Used in combination with Adjustable Top Plate.
Cantilever Support
Type 570 - 95420003
TypeInt Ømm RangeABSAP Code Plain
SAP Code Black
570125 - 200
570330
101744
130688
Used in combination with Adjustable Top Plate.
Ceiling Joist Support Arms (Pair) 9459001
TypeInt Ømm RangeABSAP Code Plain
570125 - 200
39700
130694
Used in combination with Ceiling Joist Support.
B
A
B
A
50
BA
Wall Band (60mm) 92930
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180180140
126648
126620
150200200150
127213
127196
180235238168
128110
128095
200256256178
128594
128580
A
Adjustable Back Bracketfor Wall Band 60-300mm
95950
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
125180112
126623
126622
150200132
127199
127198
180235162
128098
128097
200256186
128583
128582
Structural Wall Band (50mm) 95430
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
12518015055
101265
126654
15020017055
101266
127218
18023520055
128112
COA
20025622055
128596
COA
B
A
Structural Wall Band Extension
W1 - 95440001L1 - 95440004L2 - 95440005
TypeAdj.A B C SAP Code Plain
SAP Code Black
W155 - 100
13036-
101735
130824
L1100 - 250
300-
32101738
130825
L2100 - 440
450-
32101739
130826
AB
A
C
Type W1
Types L1, L2
Ceiling Joist Support 94590
Int ØmmExt ØmmASAP Code Plain
125180321
126669
150200341
127238
180238379
128125
200256397
128609
COA : Code on application
A A
700
39
14
Support Components (contd.)
A
A
BA
330
330
B
A
* Codes and Finish OptionsPlain BA Stainless Steel 9580P0 + Ext Ø Black Painted RAL 9005 Matt 9580B0 + Ext Ø
1 Piece Trim Collar 90˚ 9580*
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180184330
127038
127039
150200204350
127642
127643
180235242388
128133
128134
200256260406
128618
128619
* Codes and Finish OptionsPlain BA Stainless Steel 9599P0 + Ext Ø Black Painted RAL 9005 Matt 9599B0 + Ext Ø
2 Piece Trim Collar 90˚ 9599*
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
125180184330
127040
127041
150200204350
127644
127645
180235242388COA
COA
200256260406
COA
COA
Roof Support 94640
Int ØmmExt ØmmSAP Code Plain
125180
100962
150200
100963
180235
128126
200256
128610
Guy Wire Bracket 95900
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
100641
131808
150200
100642
127202
180235
128101
COA
200256
128586
COA
Wall Sleeve 90˚
Int ØmmExt ØmmA Masonry
A Timber F
SAP Code Masonry
SAP Code Timber F
125180230300
126642
126647
150200250320
127206
127212
180235288358
COA128108
200256306376
COA128592
Masonry - 94980Timber Frame - 94810
Supplied as a 1m long mitred tube to be cut to length on site
Wall Sleeve 45˚
Int ØmmExt ØmmA Masonry
A Timber F
SAP Code Masonry
SAP Code Timber F
125180230300
126641
126643
150200250320
127205
127207
180235288358
128102
128103
200256306376
128587
128588
Masonry - 94620 Timber Frame - 94910
COA : Code on application
15
BD
A C
B
D
A C
* Codes and Finish OptionsPlain BA Stainless Steel 9589P0 + Ext Ø Black Painted RAL 9005 Matt 9589B0 + Ext ØWhite Painted RAL 9016 Matt 9589W0 + Ext Ø
1 Piece Trim Collar 45˚ 9589*
Int ØmmExt ØmmABCDSAP Code Plain
SAP Code Black
SAP Code White
125180184259330454
126612
126613
126614
150200204287350483
127186
127187
127188
180235242341388536
128089
128090
128091
200256260366406562
128575
128576
128577
* Codes and Finish OptionsPlain BA Stainless Steel 9579P0 + Ext Ø Black Painted RAL 9005 Matt 9579B0 + Ext ØWhite Painted RAL 9016 Matt 9579W0 + Ext Ø
2 Piece Trim Collar 45˚ 9579*
Int ØmmExt ØmmABCDSAP Code Plain
SAP Code Black
SAP Code White
125180184130330227
127035
127036
127037
150200204144350242
127639
127640
127641
180235242171388268
128130
128131
128132
200256260183406281
128615
128616
128617
Flashings
AA
150
Angled Flashing Kit 5˚- 45˚ 95510
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
125180610
126621
COA
150200700
127197
130662
180235700
128088
COA
200256800
128574
COA
Flat Flashing Kit 95530
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
125180610
126625
COA
150200610
127201
131807
180235610
128100
COA
200256610
128585
COA
150
A A
Storm Collar 95560
Int ØmmExt ØmmSAP Code Plain
SAP Code Black
125180
106140
126645
150200
106141
127209
180235
128106
128105
200256
128590
COA
Uniflash
Product CodeExt ØmmASAP Code
9454000180 - 100
500112198
94540002150 - 300
685112197
94540003250 - 450
800114341
Universal EPDM rubber/aluminium flashing. Just pull the required diameter tab on the rubber seal.
50
A A
COA : Code on application
Terminals
Distance to Combustibles (see p.17)
A
A
B
60mm
60mm
INTERNAL HOUSECombustible Floors
Fig. 1 Fig. 2
60mm
INTERNAL BUNGALOW(VENTILATED LOFT SPACE)Combustible and Non-Combustible Floors
Raincap with10mm sparkguard DN8A145
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
12518026690
125336
COA
15020026690
126112
COA
180235362217
126846
COA
200256362220
127430
COA
Raincap with 25mm anti-bird mesh DN8A140
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
12518026690
125337
125335
15020026690
126113
126115
180235362217
126847
126845
200256362220
127431
127432
Raincap without mesh DN8A142
Int ØmmExt ØmmABSAP Code Plain
SAP Code Black
12518026690
125144
125145
15020026690
125837
125839
180235362217
126574
126575
200256362220
127153
COA
Insulated Tapered Terminal DN8A038
Int ØmmExt ØmmASAP Code Plain
SAP Code Black
125180200
125351
125352
150200200
126130
126129
180235204
126857
126858
200256240
127441
COA
COA : Code on application
16
17
InstallationThese notes should be read in conjunction with the detailed Eco ICID Installation Instructions.
MANDATORY REQUIREMENTSConnection to an appliance that is connected to the fuel supply must be carried out by a GAS SAFE (gas) or OFTEC (oil) registered installer. We recommend the use of HETAS approved installers for solid fuel applications. For full design and installation details the key referral documents are:
• BS EN 1856-1: Chimneys - System Chimney Products• BS EN 1859: Metal Chimneys - Testing Methods• BS EN 1443: Chimneys - General Requirements• BS EN 15287-1: Chimneys. Design, installation and commissioning of chimneys. Chimneys for non-roomsealed heating appliances.• BS 5440-1: Fluing and ventilation for gas appliances of rated input not exceeding 70kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys.• Approved Document J: - Combustion appliances and fuel storage systems (England & Wales)• DFP Technical Booklet L: - Combustion appliances and fuel storage systems (NI)• Technical Handbook (Domestic & Non Domestic), Section 3 - Environment (Scotland)• Appliance Installation Instructions and related standards.
Other standards covering specific applications will also be relevant and must be adhered to.
Planning permission may be required, and reference should be made to the local Building Control Department.
ENCLOSURE/SHAFTSWith the exception of the room containing the appliance, where the chimney passes through any part of the building, where there is a risk of accidental human contact, i.e a bedroom etc., or where there is a risk of contact with combustible materials stored in a cupboard or in the roof-space, the chimney must be enclosed in an appropriate way to meet Building Regulations. This can be achieved by boxing in the chimney in habitable rooms, or by the use of a protective wire mesh frame in roof spaces etc. In all cases the minimum distance to any combustible material, including loft insulation, must be respected according to the table on p.2, and any enclosure should be ventilated using the appropriate ventilated fire stops (see p.7).
DISTANCE TO COMBUSTIBLES In accordance with building regulations its is essential that the correct distance to combustible material is maintained. On solid fuel applications, where there is a risk of soot fire, a distance of 60mm to combustibles must be maintained within a combustible floor and within a combustible shaft (see Fig.1 p.10). There is no need to line the area within the floor cavity with plasterboard; however the ventilated fire stop plate and ventilated support plate must be used.*
On gas and oil applications, a distance of 50mm to combustibles must be maintained within a combustible floor and within a combustible shaft. The ventilated fire stop plate and ventilated support plate must be used.*Where the chimney penetrates a non combustible floor and where a non combustible shaft is used, a distance of 50mm to the shaft is sufficient. In this case, non ventilated fire stops and non ventilated support plates may be used at first floor level with a ventilated fire stop being used where the chimney penetrates into the roof space.*
*On bungalow applications where the chimney runs through either a combustible or non-combustible ceiling, an unventilated bungalow fire stop plate kit can be used. Please note that an unventilated support plate can not be used above the ceiling in this case. The weight of the chimney should be supported using the roof support (see p.9). Distance to combustibles must be respected within the ceiling space (see Fig. 2 p.10) and mesh frame should be used within the loft space, which must be ventilated (see Fig. 2 p.10).
JOINTING SYSTEMAll joints in the Eco ICID chimney range, which require a locking band, are made by means of a simple twist lock jointing method. This is achieved by pushing together the male and female collars on each end of the main chimney components and twisting the components through 1/6 of a turn to lock the collars into place. t should be noted that the female collars on elbows and tees are not fluted in order to allow for these items to be positioned according to requirements on site. In all cases the joints should be held securely in place using the locking band, which is supplied with all components with a female collar.
Joints are not permitted within wall and ceiling spaces. Any flue pipe (i.e. single wall) connection to the chimney must be made in the same room as the appliance. The chimney must project at least 425mm below the ceiling. Where a chimney passes through a wall, a wall sleeve must be used to prevent damage to the chimney and the building.
CONNECTION TO APPLIANCEUse the appropriate appliance connector, sealing with fire rope and fire cement or high temperature sealant on solid fuel. The length of the inner liner can be trimmed where required to allow for thermal expansion within the appliance outlet spigot.
APPLIANCE REMOVALUse of an adjustable length immediately above the appliance enables removal of the appliance later without dismantling the full system.
INSPECTIONTo conform to Building Regulations, provisions should be made to enable a chimney to be inspected and cleaned. An inspection length or an insulated 90˚ or 135˚ Tee can form a suitable inspection point. To aid cleaning, sufficient distance should be left between changes of direction to permit the safe passage of cleaning brushes within the system. This is particularly important on solid fuel applications. It is recommended that chimneys serving solid fuel appliances be swept as frequently as necessary, but at least twice a year.
CHIMNEY DIAMETERThe chimney size should be as recommended by the appliance manufacturer and must satisfy the flue sizing requirements of EN13384-1 for single appliances, and EN13384-2 for multi appliances.
CHIMNEY ROUTEThe chimney should remain as straight as possible through its verticalrun to assist flow. Should it be necessary to offset a chimney run then the following guidelines should be adhered to: It is recommended that a vertical run of at least 600mm should be allowed immediately above the appliance prior to any change of direction. Within a system, on all fuels, there should be no more than 4 changes of direction of maximum 45˚. 90˚ Factory made bends or tees within the system may be treated as being equal to two 45˚ bends (as per Document J of the Building Regulations issued October 2010).
For a direct link to the Eco ICID Installation Instructions scan the QR code.
Scan QR code to download the Schiedel Installation App incorporating Product Warranty Registration function.
Schiedel Chimney SystemsCrowther EstateWashingtonTyne & Wear NE38 0AQTel. +44 (0)191 416 1150Fax. +44 (0)191 415 [email protected]
Complementary products and servicesfrom Schiedel Chimney Systems
ICSTwin Wall Insulated System Chimney for gas,oil and multi-fuel applications.
• Simple push-fi t jointing system• High effi ciency Superwool insulation blanket• Capillary break prevents moisture being drawn through the joint• 80-300mm Diameter range
PRIMA PLUSSingle Wall Stainless Steel Flue System.
• Prima Plus available 0.6mm or 1mm options for domestic multi-fuel stoves• Prima Plus for large residential & commercial condensing gas & oil appliances & chimney relining• 80-300mm Diameter range
PRIMA SMOOTHSingle Wall Stainless Steel Connecting Flue Pipe for use on wood and multi-fuel applications.
• 316L Grade stainless steel• Available in matt black or steel fi nish• Excellent aesthetics• Lightweight• 125-200mm internal diameters
DM & LINERSPumice System Chimneys, Firechests and Liners.
full details at www.schiedel.co.uk
www.youtube.com/user/SchiedelUK www.linkedin.com/company/schiedel-ukwww.linkedin.com/company/schiedel-uk
HETAS TRAININGCourses H001-H006 available. See website for course prospectus and application form downloads.
TECNOFLEX PLUSFor relining existing chimneys to take gas, oil,wood, multi-fuel appliances and open fi res.
• Twin skin TecnoFlex Plus available in 316L or 904L options for oil, wood, multi-fuel & open fi res• 80-300mm Diameter range
ABSOLUT XPERTThe world’s 1st Passivhaus certifi ed chimney system.
• GW3 rated - condensate resistant after a chimney fi re
• Safe connection to room sealed appliances passes blower door test with no additional rendering of the blocks