ecofit - s; e
TRANSCRIPT
ECOFIT ™Masterpact M
Catalogue 2017Masterpact M to Masterpact MTZ upgrade solutions
Couv.2
The following sales promotion manual applies to substitution of non communicating circuit breakers.
Schneider Electric specialists are available to support and upgrade current installation with the latest communicating solution.
OPEN THE DOOR TO ENERGY MANAGEMENT
1
Panorama - How to choose ?
Plug & Play
Masterkit
Appendix: Masterpact MTZ spare parts
Appendix: ECOFIT™ Plug&Play spare parts
ContentsMasterpact M ECOFIT™
A
B
C
D
E
Your requirements
Service continuity
Safety
Energy efficiency and
Energy management
Our ECOFIT™ offers
Service continuity & SafetySchneider Electric recommends that routine inspections and periodicmaintenance are carried out by qualified personnel in accordance with the instructions in the Masterpact MTZ circuit breaker maintenance guide and Masterpact M circuit breaker instruction sheet.Our professional engineers and qualified field services representatives are committed to providing you with innovative solutions, best-in-class customer service, advanced technical support, and exceptional quality in everything they do.As electrical distribution specialists, we have extensive knowledge and experience in maintenance.With Masterpact MTZ Associated Services, you can count on Schneider Electric Field Services to manage your installation through the entire lifecycle of your equipment.
Energy efficiency and Energy managementAs well as offering proven performance, reliability, and safety, ECOFIT™ solutions using Masterpact MTZ now incorporate the latest digital technologies.ECOFIT™ embeds all communication functionality as well as Class 1 accuracy power/energy measurement for smart operation. ECOFIT™ connects your electrical switchboard to any building and energy management system. Now you can use your smart phone as main HMI to monitor and control ECOFIT™ solutions using Masterpact MTZ for convenience and easy management.ECOFIT™ solutions using Masterpact MTZ offers the ultimate in power uptime and energy efficiency.
ECOFIT™ = tested, validated and certified by Schneider Electric
Schneider Electric has been the benchmark for air circuit breakers (ACB) in electrical distribution since 1986; first with the Masterpact M, followed by the Masterpact NT/NW. Masterpact incorporates the most innovative features, along with its legendary breaking principle and modular design.Schneider Electric is building on this heritage with Masterpact MTZ, the connected breaker.
The aim of the ECOFIT™ solutions using Masterpact MTZ consists of supplying turnkey solutions ■ to extend the life time of the electrical switchboard;■ to give a boost to the electrical switchboard for efficient operationand energy management.
Sales period Guaranteedavailabilityof parts
Availability of parts notguaranteed
2003 End of sales
2013 limited
spare parts1986
Launch
Masterpact M
PANORAMAPANORAMA
HOW TO CHOOSE?
A
Panorama How to choose?
Table of Contents
ECOFIT™ Plug & Play ...........................................................A-2
ECOFIT™ Masterkit ................................................................A-4
Energy efficiency and Energy management .................A-6
How to choose? .......................................................................A-8Masterpact substitution guide ......................................................... A-8Control unit substitution guide ....................................................... A-11
A-1
Panorama - How to choose?
A
ECOFIT™ Plug & Play
ECOFIT™ Plug & Play applications b Drawout circuit breakers. b 800 to 3200 A. b All performance levels except for L1. b Communication: Consult Schneider Electric specialist to support and upgrade current installation with latest communicating solution.
b ECOFIT™ Masterpact Plug & Play does not cover 1000 V and DC applications nor Masterpact MTZ with corrosion protection.
b ECOFIT Masterpact Plug & Play can not be used if the Masterpact M chassis is equipped with a test position switch (CT) solution.
b For drawout switch-disconnectors, the ECOFIT Plug and Play solution is only available with a Masterpact NW switch-disconnector and not with a Masterpact MTZ.
Rating Fixed Withdrawable6300 A4000 A3200 A Plug & Play
solutions800 A
Temperature deratingThe table below indicates for Masterpact M, the maximum current rating, for each connection type, as a function of the ambient temperature around the circuit breaker and the busbars.The same temperature derating applies to the ECOFIT Plug & Play solution.
Masterpact M M08N/H M10N/H M12N M12H M16N/H M20N/H M25N/H M32HVersion Connection T °CDrawout Front or rear
horizontal40 800 1000 1250 1250 1600 2000 2500 315045 800 1000 1250 1250 1600 2000 2500 308050 800 1000 1250 1250 1600 2000 2430 300055 800 1000 1250 1250 1600 2000 2350 290060 800 1000 1250 1250 1550 1900 2250 2800
Rear vertical 40 800 1000 1250 1250 1600 2000 2500 320045 800 1000 1250 1250 1600 2000 2500 320050 800 1000 1250 1250 1600 2000 2500 310055 800 1000 1250 1250 1600 2000 2500 300060 800 1000 1250 1250 1550 1900 2400 2900
PB11
5676
.eps
Masterpact M chassis
Masterpact M
Masterpact MTZ
The Plug & Play solution lets you retrofit the latest generation of Masterpact MTZ circuit breakers in the existing Masterpact M chassis.The standard Masterpact MTZ is adapted in the factory for installation in a Masterpact M chassis.More than just a replacement... ECOFIT™ Plug & Play solution brings all the benefits of the Masterpact MTZ range, including the advanced features of Micrologic X control units.
A Plug & Play solution can only be implemented with Masterpact M chassis in full working order, please see section A-9 for details.
A-2
Panorama - How to choose?
AInstallation in 2 steps by qualified personnel
b The original Masterpact M chassis is first modified to receive the Plug & Play device.
b The factory-adapted Plug & Play Masterpact MTZ is then installed in the modified Masterpact M chassis.
On-site retrofit operations are easy to implement
1. Replacement of the original drawer side platesTwo new side plates are installed in place of the original plates on the Masterpact M chassis.
2. Replacement of the the auxiliary wiring connector plateMasterpact MTZ functions are pre-wired. The required functions may be connected on-site using the supplied wiring instructions.
b The switchboard door requires no modifications. b The original escutcheon and cutout are used for the new device. b The only modifications required are the replacement of the drawer side plates and the auxiliary wiring connector plate.
b These changes make it impossible to install a Masterpact M or standard Masterpact MTZ in the modified chassis, only a factory-adapted Plug & Play Masterpact MTZ can be installed.
ECOFIT™ Plug & PlayPE
9045
1.ep
sPE
9045
1.ep
s
b The Plug & Play solutions modernise Masterpact M circuit breakers with very short on-site servicing times. It is also ideal for switchboards installed in small rooms with no rear access.
b The combination of a Masterpact M chassis and a Masterpact MTZ circuit breaker has been factory tested, in particular for temperature rise and breaking capacity.
b The Plug & Play Masterpact MTZ complies with standard IEC 60947-2.
A-3
Panorama - How to choose?
A
ECOFIT™ Masterkit
ECOFIT™ Masterkit advantages b No modification of power circuit connections required.
b No modification of the escutcheon or cutouts required (up to M32).
b Tested and validated connection systems to bring full performance in terms of
breaking capacity and temperature rise.
ECOFIT™ Masterkit brings the characteristics and functions of the Masterpact MTZ range, whatever the rating and performance level of the Masterpact M device.This solution is recommended for high performance levels to upgrade your installation.The ECOFIT™ Masterkit solution is designed to replace a Masterpact M circuit breaker by the latest Masterpact MTZ generation.More than just a replacement…ECOFIT™ Masterkit solution brings the benefits of the Masterpact MTZ range, including the advanced features of Micrologic X control units.
1. Removal
Masterpact M chassis
Masterpact M
PE50
826_
107.e
ps
2. Replacement
PB11
5682
.eps
Masterpact MTZ
PE90
455.
eps
BUSBAR NOT MODIFIED
ECOFIT™ Masterkit applicationsCan be used for both fixed and drawout devices with rear connections only.
b For fixed devices, the Masterpact MTZ comes with connections that enable the replacement of the former circuit breaker without the modification of the busbars.
b For drawout device, the new chassis is equipped with special connections that replicate the connection points on the old Masterpact M chassis.
ECOFIT™ Masterkit solutions do not cover neither 1000V and DC applications nor ratings higher than M32 4P with Neutral on right side. Consult Schneider Electric services (Grenoble ECOFIT center).ECOFIT™ Masterkit solutions are not suitable for Masterpact with corrosion protection.
Rating Fixed Withdrawable6300 A [1]
Masterkit solutions
4000 A3200 A [2]
800 A[1] For 5000A: version 3P fixed only; for 6300A drawout horizontal connections: consult us.[2] For L1: only drawout version for M08 to M20.
b ECOFIT™ Masterkit brings all the benefits of the enhanced features of Masterpact MTZ circuit breakers and accessories. The installation requires access to the busbars.
b Once upgraded, the switchboard is fully compatible with the Masterpact MTZ range, opening the door to circuit-breaker interchangeability.
b Installation down-time is reduced because there is no need to modify the busbars.*
b The ECOFIT™ Masterkit complies with standard IEC 60947-2.
* Refer to table page A-5 (Overlapping of busbar connections )
A-4
Panorama - How to choose?
ATemperature deratingThe table below indicates for Masterpact M, the maximum current rating, for each connection type, as a function of the ambient temperature around the circuit breaker and the busbars.The same temperature derating applies to the ECOFIT™ Masterkit solution [3].
Masterpact M M08 N/H
M08 L
M10 N/H
M10 L
M12 N/H
M12 L
M16 N/H
M16 L
M20 N/H
M20 L
M25 N/H
M32 H
M40 H
M50 H
M63 H
Version Connection T °CDrawout Front or rear
horizontal40 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3150 3800 500045 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3080 3650 475050 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2430 3000 3500 450055 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2350 2900 3300 425060 800 800 1000 1000 1250 1250 1550 1500 1900 1900 2250 2800 3100 4000
Rear vertical
40 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 4000 5000 630045 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3200 3800 5000 600050 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3100 3600 5000 570055 800 800 1000 1000 1250 1250 1600 1600 2000 2000 2500 3000 3400 5000 540060 800 800 1000 1000 1250 1250 1550 1600 1900 1900 2400 2900 3200 4700 5100
Fixed Front or rear horizontal
40 800 1000 1250 1600 2000 2500 3200 4000 500045 800 1000 1250 1600 2000 2500 3200 4000 500050 800 1000 1250 1600 2000 2500 3200 4000 500055 800 1000 1250 1600 2000 2500 3200 3900 500060 800 1000 1250 1600 2000 2500 3100 3800 5000
Rear vertical
40 800 1000 1250 1600 2000 2500 3200 4000 500045 800 1000 1250 1600 2000 2500 3200 4000 500050 800 1000 1250 1600 2000 2500 3200 4000 500055 800 1000 1250 1600 2000 2500 3200 4000 500060 800 1000 1250 1600 2000 2500 3100 3900 5000
[3] For M40 fixed and drawout versions, Masterkit solution is limited to 3200 A at 35° C, 3160 A at 45° C and 2960 A at 55° C.
ECOFIT™ Masterkit
A
B
Masterpact M
DB4
2452
1.ep
s
Busbar connections
Masterpact M terminals
Typeof replacement
Dimensions
A B (Maximum) A B (Maximum)
M08-40 with MTZ2Fixed 3-pole and 4-pole Drawout 3-pole and 4-pole
M08-16 / MTZ2 08-16 Vertical Rear connections
12.5mm 35mm 12.5mm 35mm
M20-25 / MTZ2 20-25Vertical Rear connections
12.5mm 30mm 12.5mm 30mm
M32 / MTZ2 32Vertical Rear connections
15mm 15mm 15mm 15mm
M40 / MTZ2 40 Vertical Rear connections
15mm 35mm 15mm 35mm
M08-16 / MTZ2 08-16 Horizontal Rear connections
17mm 17mm 12.5mm 17mm
M20-25 / MTZ2 20-25Horizontal Rear connections
18mm 22mm (Upstream)15mm (Downstream)
12.5mm 22mm (Upstream)15mm (Downstream)
M32 / MTZ2 32Horizontal Rear connections
15mm 15mm 15mm 16mm
M40 / MTZ2 40 Horizontal Rear connections
15mm 17mm 15mm 17mm
M50-63 with MTZ3Fixed 3-pole Drawout 3-pole and 4-pole
M50 / MTZ3 50 Vertical Rear connections
15mm 35mm 15mm 35mm
M50 / MTZ3 50 Horizontal Rear connections
15mm 17mm 15mm 29mm
M63 / MTZ3 63Vertical Rear connections
Na Na 15mm 35mm
Overlapping of busbar connectionsCheck the overlapping dimension of the power busbars of the Masterpact M. If dimension is higher than B, Masterkit can not be used unless busbars are modified.
A-5
Panorama - How to choose?
AECOFIT™ Plug & Play, ECOFIT™ Masterkit solutions using Masterpact MTZ with Micrologic X, bring you more
Communicationp It is now usual to make available most
of the information processed by a Protection Control Unit, locally for network operation and maintenance, and remotely for higher functions of control, monitoring, energy efficiency and assets management.
p To comply with this requirement Micrologic X, incorporates several channels of communication, including Ethernet and wireless communication facilities.
Diagnostics & MaintenanceOptimal continuity of services as well as extended life of equipment is one of customers main concerns. For that purpose Micrologic X integrates new extended diagnosis and assistance to maintenance.
ProtectionImprovement of the reliability of Micrologic X, dual settings and additional facilities increase the performance and the flexibility of low voltage systems of protection.
MeasurementEnergy management is the challenge of present & future generations.To meet this requirement Micrologic X incorporates all the measuring functions of a power meter including Energy Class 1 accuracy third-party party certified.
4 Optional 24/7 downloadable digital modules dedicated to upgrading Micrologic X
p Energy per phase
p Power restoration assistant
p Masterpact operation assistant
p Waveform capture on trip event
PB11
6185
_35.
eps
Energy efficiency and Energy management
As energy costs increase and more stringent greenhouse gas emission regulations are introduced, it is essential to find ways to reduce energy consumption.
A-6
Panorama - How to choose?
A
Energy efficiency and Energy management
... Micrologic 6.0X
... Micrologic 7.0X
> Protection for ...> Additional features of protectionsAlong with the LSIGV protections, new additional features and facilities allow to improve the protection performance of a system when difficulties are met such as low values of the short circuit current or the need to limit the thermal constraints to the equipment: dual setting, fine setting, zone selective interlock, fast tripping.
> MeasurementMicrologic X measures all electrical parameters of an electrical network: Currents, voltages, frequency, power, energy power factor, current and power demand. Min/Max and average values are calculated for most of the parameters.Optional digital modules allow the measurement of energy per phase, and to perform wave form capture.
> Diagnostics & MaintenanceDiagnostic features are intended to limit the risk of power interruptions and to re-energize the installation as quickly as possible after a trip.They provide warnings and messages to help the user in scheduling both preventive and predictive maintenance, and device replacement.
> CommunicationNew generation Micrologic X incorporates wireless technology (Bluetooth and NFC) that allow to get most of the critical information (protection, measurements, diagnostics and maintenance) inside your mobile device by means of Masterpact MTZ mobile App. Alternativelly, Masterpact MTZ can be equipped with ETHERNET communication through either IFE module or the new embedded EIFE that includes embedded webpages.
> Optional digital modulesAs an option four digital modules are available on Schneider Electric WEB Site. They can be downloaded 24/7 to upgrade Micrologic X.
ECOFIT™ Plug & Play or ECOFIT™ Masterkit solutions using Masterpact MTZ with Micrologic X: Go digital and take advantage of Schneider Electric services throughout the product lifecycle, thanks to the native connectivity of Masterpact MTZ.
b Leverage Masterpact MTZ data and intelligence to implement Services actions relating Maintenance, Remote Facility Management, Asset Management and Energy Management.
b Native connectivity of Masterpact MTZ integrated into the Smart Panels architecture generates remote data collection, enabling Services including:
v Maintenance planning with Facility Hero, the digital maintenance log book v Facility management with Facility Insights b Condition Base Maintenance with permanent equipment monitoring, to define the right moment to maintain.
b Asset management & Alarm management, to improve facility operation management.
b Energy Efficiency & Power Quality management, to optimize energy costs, assets utilization and facility operations.
... Micrologic 2.0XLI: Long-time
+ Instantaneous
DB4
1972
6.ai
... Micrologic 5.0XLSI: Long-time
+ Short-time+ Instantaneous
DB4
1972
7.ai
LSIG: Long-time + Short-time+ Instantaneous + Earth fault
LSIV : Long-time + Short-time+ Instantaneous + Earth leakage
DB4
1972
7.ai
DB4
1972
8.ai
DB4
1972
7.ai
DB4
1972
9.ai
Note: Please refer to the Masterpact MTZ catalogue for more details.
Services
Gateway
Asset
A-7
Panorama - How to choose?
A
How to choose?Masterpact substitution guide
Identification of the device to be replacedA Rated insulation voltage.B Breaking capacity.C Short time withstand.D Type of breaker.E Rated frequency.F Rated operational voltage.
MERLIN GERINmasterpactM25 H2Ui 1000V ~ 50/60Hz
Ue 380/440V 480/690V
Icu 100kA 85kA
Ics 100kA 85kA
Icw 75kA 1s
IEC 947-2
PE90
613.
eps
A
B
C
D
E
F
Selection of the replacement device
[1] Or H1 if Isc < 66 kA.[2] L type only with Masterkit solution.[3] For ECOFIT Plug&Play solution, use only the solution with Masterpact NW.[4] No HF performance level with Masterpact MTZ yet.
Circuit breaker (Icu 220/440 V)Original Masterpact M circuit breaker frame size 3P/4P
Replacement Masterpact MTZ circuit breaker frame size 3P/4P
Original Masterpact M circuit breaker type
Replacement Masterpact MTZ circuit breaker type
Original Masterpact M circuit breaker type
Replacement Masterpact MTZ circuit breaker type
Original Masterpact M circuit breaker type
Replacement Masterpact MTZ circuit breaker type
Original Masterpact M circuit breaker type
Replacement Masterpact MTZ circuit breaker type
M08 MTZ2 08 N1 (40 kA) N1 (42 kA) H1 (65 kA) H1 (66 kA) H2 (100 kA) H2 (100 kA) L1 (130 kA) [2]
L1 (150 kA)
M10 MTZ2 10 N1 (40 kA) N1 (42 kA) H1 (65 kA) H1 (66 kA) H2 (100 kA) H2 (100 kA) L1 (130 kA) [2]
L1 (150 kA)
M12 MTZ2 12 N1 (40 kA) N1 (42 kA) H1 (65 kA) H1 (66 kA) H2 (100 kA) H2 (100 kA) L1 (130 kA) [2]
L1 (150 kA)
M16 MTZ2 16 N1 (40 kA) N1 (42 kA) H1 (65 kA) H1 (66 kA) H2 (100 kA) H2 (100 kA) L1 (130 kA) [2]
L1 (150 kA)
M20 MTZ2 20 N1 (55 kA) H1 (66 kA) H1 (75 kA) H2 (100 kA) [1] H2 (100 kA) H2 (100 kA) L1 (130 kA) [2]
L1 (150 kA)
M25 MTZ2 25 N1 (55 kA) H1 (66 kA) H1 (75 kA) H2 (100 kA) [1] H2 (100 kA) H2 (100 kA) - -M32 MTZ2 32 - - H1 (75 kA) H2 (100 kA) [1] H2 (100 kA) H2 (100 kA) - -M40 MTZ2 40 - - H1 (75 kA) H2 (100 kA) [1] H2 (100 kA) H2 (100 kA) - -M50 MTZ3 50 - - H1(100kA) H1 (100 kA) H2 (150 kA) H2 (150 kA) - -M63 MTZ3 63 - - H1(100kA) H1 (100 kA) H2 (150 kA) H2 (150 kA) - -
Switch-disconnector (Icw kA rms 1s AC 50/60Hz)Original Masterpact M switch-disconnector frame size 3P/4P
Replacement Masterpact MTZ switch-disconnector frame size 3P/4P
Original Masterpact M switch-disconnector type
Replacement Masterpact MTZ switch-disconnector type
Original Masterpact M switch-disconnector type
Replacement Masterpact MTZ switch-disconnector type
Original Masterpact M switch-disconnector type
Replacement Masterpact MTZ switch-disconnector type
M08 MTZ2 08 NI (30 kA) NA (42 kA) [3] HI (50 kA) HA (66 kA) [3] HF (50 kA) NW type HF (85 kA) [4]
M10 MTZ2 10 NI (30 kA) NA (42 kA) [3] HI (50 kA) HA (66 kA) [3] HF (50 kA) NW type HF (85 kA) [4]
M12 MTZ2 12 NI (30 kA) NA (42 kA) [3] HI (50 kA) HA (66 kA) [3] HF (50 kA) NW type HF (85 kA) [4]
M16 MTZ2 16 NI (30 kA) NA (42 kA) [3] HI (50 kA) HA (66 kA) [3] HF (50 kA) NW type HF (85 kA) [4]
M20 MTZ2 20 NI (55 kA) HA (66 kA) [3] HI (75 kA) NW type HF (85 kA) [4]
HF (75 kA) NW type HF (85 kA) [4]
M25 MTZ2 25 NI (55 kA) HA (66 kA) [3] HI (75 kA) NW type HF (85 kA) [4]
HF (75 kA) NW type HF (85 kA) [4]
M32 MTZ2 32 - - HI (75 kA) NW type HF (85 kA) [4]
HF (75 kA) NW type HF (85 kA) [4]
M40 MTZ2 40 - - HI (75 kA) NW type HF (85 kA) [4]
HF (75 kA) NW type HF (85 kA) [4]
M50 MTZ3 50 - - HI(I00kA) - HF (100 kA) -M63 MTZ3 63 - - HI(I00kA) - HF (100 kA) -
A-8
Panorama - How to choose?
ABefore ordering a Plug & Play solution, check the condition of the chassis as indicated below.
Visual inspectionCheck overall condition. Look for visible cracks.
Check for any bent or distorted parts that could hinder insertion of the Masterpact circuit breaker.
Measure the diagonals to make sure the chassis is not distorted or warped. Squareness chassis ±3 mm.
(A = B)
Auxiliary wiring connector plate
A B
Check visually for any deformed parts (e.g. inward or outward bulges)
Note: Make sure there are no visible cracks on the chassis.
Check that all moving parts (pawls, cams) work properly.
Check cradle warm screw:b Disconnected position without
the breakerb Nuts abutment rear (x2)b Connect until the return of the hookb Crank to remain => One turn
+ ¼ maximumb Nuts abutment intermediate (x2)b If not ok => Make adjustment.
How to choose?Masterpact substitution guide
Carry out a racking test (in and out) 3 times without the circuit breaker and check the movement of:
b the safety shutters, b the auxiliary wiring connector plate, b the drawer side plates.
ECOFIT™ - Plug & Play solution requires Masterpact M chassis in full working order.If the chassis is bent or damaged, a Plug & Play solution is not possible and the Masterkit solution must be used.
Check the contact clusters. If they are in good condition, clean and lubricate them. If not, replace them.
Schneider Electric has developed dedicated diagnostic tool (ProDiag Cluster) to check clusters condition
A-9
Panorama - How to choose?
A Source Changeover
Masterpact M with external neutral current sensor
Mechanical interlocking for source changeoverWhen replacing a Masterpact M using a Masterkit solution (fixed or drawout):
b Mechanical interlocking between Masterpact M and MTZ devices is forbidden.
b Both Masterpact M devices must be replaced as well as the corresponding interlocking system.
When replacing a Masterpact M using a Plug & Play solution (drawout): b Mechanical interlocking is carried out on the Masterpact M chassis. b A Masterpact M may interlocked with a Plug & Play device if indicated when ordering.
Electrical interlocking for source changeover b Electrical interlocking is possible between Masterpact M and MTZ devices. b The same components are used, i.e. IVE unit, BA and UA automatic controllers.
3-pole breakers equipped with external neutralcurrent sensorWhen replacing a Masterpact M by a Masterpact MTZ using a Plug & Play or Masterkit solution:
b The current transformer used with the STR control unit is not compatible with Micrologic control units
b A new current transformer compatible with Masterpact MTZ must be added.
This requires total disconnection of the busbars prior to working on the external CT. b In case of distribution network with several circuit breakers with ground fault protection, change all circuit breakers and their external CT's.
Mechanical interlocking
BA controller IVE unit
The Plug&Play breaker must be equipped with an interlocking cam for mechanical interlock (reference = EF548613).
How to choose?Masterpact substitution guide
DB1
2626
8b.e
psD
B403
809.
eps
DB4
2453
2.ep
s
A-10
Panorama - How to choose?
A
How to choose?Control unit substitution guide
Identify the control unitA D: standard protection / S: selective protection /
U: universal protectionB T: earth-fault protection.C R: load monitoring.
Selection of the control unitThe table below shows some possible choices between the obsolete STR and Micrologic control units.
push to reset
II1 I2 I3
90%
50%
20%
STR 38 S
xIn xIoIm tm
xIr on I2t off
Ir fault
tr
Im faulttm
I
faultIh
th
t
i
test+ –
– +
T
Ftest
Ih th
A on I2t off
I
xIn
Ir :
Im :
th :
overcurrent
ground
90
105%Ir
Io
0.5
0.63 0.8
1
Ir.88
.9 .92.95.98
1.8.85
34 5
68
101.52
.3.4 .3
.2
.10.1
.2
max. off
400500 600
8001000
1200250320
.3.4 .4
.3
.2.1.1
.2
PE90
613-
2.ep
s
A
B
C
Masterpact MTZ control units
Micrologic X
Masterpact M control units 2.0 5.0 6.0 7.0
STR28D
STR38S
STR58U
STR68U
Note: Please refer to the Masterpact MTZ catalogue for more details.
A-11
Panorama - How to choose?
PLUG & PLAYPLUG & PLAY
ECOFIT™ Masterpact M Plug & Play
Presentation ..............................................................................B-2
Order form .................................................................................B-3
MTZ2 08 to MTZ2 32 drawout circuit breakers ............B-4Control units accessories ............................................................... B-5Indication contacts ........................................................................... B-5Remote operation............................................................................. B-6Accessories .................................................................................... B-7
B-1
ECOFIT™ Masterpact M Plug & Play
B
PresentationPB
1156
76.e
ps
Masterpact M
Masterpact M chassis
Masterpact MTZ
B-2
ECOFIT™ Masterpact M Plug & Play
B
Order form(GCR_PP_MTZ2_CB)
To indicate your choice, check the applicable square boxesand enter the appropriate information in the rectangles
QuantityNumber of Devices* The quantity specified here will not affect the quantity of spare parts.
Basic ConfigurationMasterpact type P&P MTZ2Rating (3200 A max) ASensor rating ACircuit breaker N1, H1, H2Switch-disconnector Not available with Masterpact MTZ,
use P&P with Masterpact NW
Micrologic X 2.0 5.0 6.0 7.0Micrologic X with Arc 2.0 5.0 6.0 7.0Number of poles 3 4 [1]
[1] 4P = neutral on left. For neutral on right side, consult France Grenoble Ecofit CenterType of equipment Drawout without chassis
(moving part only) X
CommunicationConsult Schneider Electric specialist to support and upgrade current installation with latest communicating solution
Operation Efficiency - SignalingOF - ON/OFF indication contacts* 4 OF 6 A-240 V AC (10 A-240 V AC and low level for NW) is supplied as standardNote: Masterpact Plug&Play is not suitable in case Masterpact M chassis is equipped with a test position switch (CT)Additional 1 block of 4 OF for MTZ 2
Max. 2 Blocksqty
SDE - “fault-trip” indication contact* 1 SDE 6A - 240V AC is supplied as standardAdditional 1 SDE
6 A-240 V ACor 1 SDE Low Level
Programmable contacts 2 M2C contactsPF - “ready to close” contact Low level
6 A/240 VACCDM - mechanical operation counter MTZ2
Operation Efficiency - ControllingRemote Control MCH - gear motor V
XF - closing voltage release VMX - opening voltage release VMN - undervoltage release VR - delay unit (non-adjustable) VRr - adjustable delay unit V2nd MX- opening voltage release V2nd MN - undervoltage release VR - delay unit (non-adjustable) for 2nd MNRr - adjustable delay unit for 2nd MN
Remote Reset after tripping
RES - electrical reset option VRAR - automatic reset option
Electrical Closing BPFE - electrical closing pushbutton
People and property safety - Locking and InterlockingVBP - ON/OFF pushbutton locking (by transparent cover + padlocks)OFF position locking:VCPO - by padlocksVSPO - by keylocks Keylock kit (w/o keylock) Profalux Ronis
Kirk Castell 1 keylock Profalux Ronis 2 identical keylocks, 1 key Profalux Ronis 2 keylocks, different keys (MTZ2) Profalux Ronis
Mechanical interlock (source-changeover systems)Interlocking axle and installation kit (ref: EF548613, one per P&P )Mismatch protection (ref EF547056)
People and property safety - Circuit ProtectionTCE - external sensor (CT) for neutral
Single sensor & Single wire (MTZ2)Rectangular sensor for earth-leakage protection MTZ2/3 (470 x 160 mm)
Power Availability and reliabilityVPS - Voltage power supplyAD - external power-supply module VBAT - battery module
Digital ModuleEnergy per Phase Wave Form CaptureCircuit Breaker Restoration Circuit Breaker Reclosing
Commonly Used Spare Parts* If you would like to order some spare parts, kindly indicate here. Please note that spare parts will be delivered separately.Mobile PowerPact by APC qtyUSB CABLE qtyTransparent cover for micrologic qtyMini test kit qty
Note: Refer to Masterpact Plug & Play user manual for more informations.
ECOFIT™ Plug & Play solutions require Masterpact M chassis in full working orderIf chassis is bent or damaged, Plug & Play solution is not possible, use Masterkit solution
B-3
ECOFIT™ Masterpact M Plug & Play
B
MTZ2 08 to MTZ2 32 drawout circuit breakers
Basic Plug & Play circuit breakersType N1
In (A at 40°C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu3P 4P
P&P MTZ2 08 800 42 EF598230 EF598237P&P MTZ2 10 1000 42 EF598244 EF598251P&P MTZ2 12 1250 42 EF598258 EF598265P&P MTZ2 16 1600 42 EF598272 EF598279Type H1
In (A at 40°C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu3P 4P
P&P MTZ2 08 800 66 EF598231 EF598238P&P MTZ2 10 1000 66 EF598245 EF598252P&P MTZ2 12 1250 66 EF598259 EF598266P&P MTZ2 16 1600 66 EF598273 EF598280P&P MTZ2 20 2000 66 EF598287 EF598294P&P MTZ2 25 2500 66 EF598300 EF598306P&P MTZ2 32 3200 66 EF598312 EF598317Type H2
3P 4PIn (A at 40°C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
P&P MTZ2 08 800 100 EF598232 EF598239P&P MTZ2 10 1000 100 EF598246 EF598253P&P MTZ2 12 1250 100 EF598260 EF598267P&P MTZ2 16 1600 100 EF598274 EF598281P&P MTZ2 20 2000 100 EF598288 EF598295P&P MTZ2 25 2500 100 EF598301 EF598307P&P MTZ2 32 3200 100 EF598313 EF598318
Micrologic X control units"Class1 IEC 61557-12 certified power meter"
3P/4PMicrologic 2.0 X basic protection LV848498Micrologic 5.0 X selective protection LV848499Micrologic 6.0 X selective + earth-fault protection LV848500Micrologic 7.0 X selective + earth-leakage protection LV848362
Digital modules option3P/4P
Energy per phase LV850002Power restoration assistant LV850004Masterpact operation assistant LV850005Waveform capture trip oriented LV850003
User manual3P/4P
User manuel Masterpact P&P MTZ2 08-32 EF598001
Note: 4P are with neutral on the left. For 4P with neutral on the right: please contact Grenoble ECOFIT Center.
How to define ECOFIT Plug & Play solutions?Each Masterpact Plug & Play circuit breaker upgrade solution is described by two catalogue numbers corresponding to:b an adapted Masterpact MTZ2 circuit breaker;b a control unit.For switch-disconnectors, ECOFIT™ Masterpact M Plug&Play is not available with Masterpact MTZ yet. Use ECOFIT™ Masterpact M Plug&Play with Masterpact NW.Masterpact NW switch-disconnectors are equipped with a trip unit with a making current of 90kA peak.A communication option, various auxiliaries and accessories may also be added.
B-4
ECOFIT™ Masterpact M Plug & Play
B
MTZ2 08 to MTZ2 32 drawout circuit breakersControl units accessories
Indication contacts
Indication contactsON/OFF indication contacts (OF)
DB4
0432
1.ep
s Block of 4 changeover contacts (6 A - 240 V) 1 block (standard)1 additional block of 4 contacts (2 max.) LV848468
“Fault trip” indication contacts (SDE)
DB4
0432
3.ep
s Changeover contact (6 A - 240 V) 1 (standard)1 additional SDE (6 A - 240 V) LV848475or 1 additional low-level SDE LV848476
Programmable contacts (programmed via Micrologic X control unit)
DB4
0437
5.ep
s 2 contacts M2C (5 A - 240 V) LV848382
Accessories for Micrologic X control unitsExternal sensorsExternal sensor for earth-fault protection (TCE)
DB4
2134
9.ai
Sensor rating 400/2000 A LV834035SP1000/4000 A LV834036SP
Rectangular sensor for earth-leakage protection
DB4
0438
2.ep
s 470 mm x 160 mm In max. 3200 A LV833574SP
Source ground return (SGR) earth fault protection
DB4
0438
2.ep
s External sensor (SGR) LV833579SPMDGF summing module LV848891SP
Voltage power supply module (VPS) for Micrologic X
DB4
2140
8.ep
s LV850060
External power supply module (AD)
DB1
0536
0.ep
s 24/30 V DC 5444048/60 V DC 54441100/125 V DC 54442110/130 V AC 54443200/240 V AC 54444380/415 V AC 54445
Battery module (BAT)
L3
G1
AD 220A
L4
G2
Input
24VDC
Output
24VDCD
B404
384.
eps 1 battery 24 V 54446
Test and commisionning equipmentUSB Cable (miniUSB/USB) for Micrologic X
DB4
2140
9.ep
s LV850067SP
Mobile Powerpack for Micrologic X (by APC)
DB4
2141
0.ep
s LV850055SP
B-5
ECOFIT™ Masterpact M Plug & Play
B
MTZ2 08 to MTZ2 32 drawout circuit breakersRemote operation
Remote ON/OFFGear motor
DB4
0431
6.ep
s MCHAC 50/60 Hz 48 V LV848522
100/130 V LV848526200/240 V LV848527250/277 V LV848528380/415 V LV848529440/480 V LV848530
DC 24/30 V LV84852148/60 V LV848522100/130 V LV848523200/250 V LV848524
Instantaneous voltage releases
DB4
0431
7.ep
s Closing release Opening releaseStandard XF MXAC 50/60 HzDC
24/30 V DC, 24 V AC LV848481 LV84849148/60 V DC, 48 V AC LV848482 LV848492100/130 V AC/DC LV848483 LV848493200/250 V AC/DC LV848484 LV848494277 V AC LV848485 LV848495380/480 V AC LV848486 LV848496
Opening releaseStandard MNAC 50/60 HzDC
24/30 V DC, 24 V AC LV84850148/60 V DC, 48 V AC LV848502100/130 V AC/DC LV848503200/250 V AC/DC LV848504277 V AC -380/480 V AC LV848506
Remote operation“Ready to close” contact (1 max.)
DB4
0431
8.ep
s PF1 changeover contact (5 A - 240 V) LV8484691 low-level changeover contact LV848470
Electrical closing pushbutton
DB4
0431
9.ep
s BPFE1 pushbutton LV848534
Remote reset after fault trip
DB4
0431
5.ep
s Electrical reset RES110/130 V AC LV848472220/240 V AC LV848473Automatic reset RARAdaptation LV847346
Remote trippingInstantaneous voltage release
DB4
0431
7.ep
s 2nd MXAC 50/60 Hz 24/30 V DC, 24 V AC LV848511DC 48/60 V DC, 48 V AC LV848512
100/130 V AC/DC LV848513200/250 V AC/DC LV848514277 V AC LV848515380/480 V AC LV848516
MN delay unit
DB4
0432
0.ep
s R (non-adjustable) Rr (adjustable)AC 50/60 Hz 48/60 V AC/DC - LV833680SPDC 100/130 V AC/DC LV833684SP LV833681SP
200/250 V AC/DC LV833685SP LV833682SP380/480 V AC/DC - LV833683SP
B-6
ECOFIT™ Masterpact M Plug & Play
B
MTZ2 08 to MTZ2 32 drawout circuit breakersAccessories
Mechanical interlockInterlocking cam for mechanical interlock
DB4
2452
2.ai
Cam and installation kit EF548613
Mismatch protectionBreaker rack-in mismatch protection
DB4
0432
9.ep
s Accessory for breaker and chassis (VDC) EF547056
Circuit breaker locking Pushbutton locking device
DB4
0433
7.ep
s By padlocks LV848536
OFF position locking
DB4
0433
8.ep
s By padlocksVCPO LV848539
By Profalux keylocksProfalux 1 lock with 1 key + adaptation kit LV848545
2 locks 1 key + adaptation kit LV8485462 locks 2 different keys + adaptation kit LV848547
By Ronis keylocksRonis 1 lock with 1 key + adaptation kit LV848549
2 locks 1 key + adaptation kit LV8485502 locks 2 different keys + adaptation kit LV848551
Adaptation kit (without keylock):
adaptation kit Profalux / Ronis LV848541SPadaptation kit Kirk LV848542SPadaptation kit Castell LV848543SP
Other circuit breaker accessoriesMechanical operation counter
DB1
2561
7.ep
s Operation counter CDM LV848535
B-7
ECOFIT™ Masterpact M Plug & Play
B
MASTERKITMASTERKIT
C-1
C
ECOFIT™ Masterkit
ECOFIT™ Masterkit
Presentation ..............................................................................C-2
Order form .................................................................................C-3
MTZ2 08 to MTZ3 50 fixed circuit breakers ...................C-4Circuit breakers ................................................................................ C-4
MTZ2 08 to MTZ3 50 fixed circuit breakers and fixed switch-disconnectors .........................................C-5Connections ..................................................................................... C-5Accessories ..................................................................................... C-6
MTZ2 08 to MTZ3 50 fixed circuit breakers ..................C-7Indication contacts and remote operation ...................................... C-7Remote operation............................................................................. C-8
MTZ2 08 to MTZ3 63 drawout circuit breakers ............C-9Circuit breakers ................................................................................ C-9
MTZ2 08 to MTZ3 63 drawout circuit breakers .........C-10Chassis........................................................................................... C-10
MTZ2 08 to MTZ3 63 drawout circuit breakers and drawout switch-disconnectors ...............................C-11Connections ................................................................................... C-11Accessories ................................................................................... C-12Chassis locking and accessories .................................................. C-13
MTZ2 08 to MTZ3 63 drawout circuit breakers .........C-14Chassis locking and accessories .................................................. C-14Indication contacts and remote operation .................................... C-15Remote operation........................................................................... C-16
Accessories for MTZ2 08 to MTZ3 63 fixed and drawout circuit breakers ................................C-17
MTZ2 08 to MTZ3 50 fixed switch-disconnectors ...C-19Switch-disconnectors and connections ........................................ C-19
MTZ2 08 to MTZ3 63 drawout switch-disconnectors ...C-20Switch-disconnectors and connections ........................................ C-20
MTZ2 08 to MTZ2 32 circuit breakers with neutral on the right .....................................................C-21Circuit breakers .............................................................................. C-21
C-2
C
ECOFIT™ Masterkit
PE50
826.
eps
PB11
5682
.eps
Presentation
Masterpact M
Masterpact M chassis
C-3
C
ECOFIT™ MasterkitOrder form(GCR_MASTERKIT_MTZ2, GCR_MASTERKIT_MTZ3 GCR_MKT_MTZ2SD, GCR_MKT_MTZ3SD GCR_MKT_MTZCHASSIS)
Operation Efficiency - ControllingRemote Control MCH - gear motor V
XF - closing voltage release VXF COM - closing voltage release VMX - opening voltage release VMX COM - opening voltage release VMN - undervoltage release VMN COM - undervoltage release VR - delay unit (non-adjustable)Rr - adjustable delay unit 2nd MX- opening voltage release V2nd MX COM- opening voltage release V2nd MN - undervoltage release V2nd MN COM - undervoltage release VR - delay unit (non-adjustable) for 2nd MNRr - adjustable delay unit for 2nd MN
Remote Reset after tripping
RES - electrical reset option VRAR - automatic reset option
Electrical Closing BPFE - electrical closing pushbuttonPeople and property safety - Locking and InterlockingVBP - ON/OFF pushbutton locking (by transparent cover + padlocks)OFF position locking:VCPO - by padlocksVSPO - by keylocks Keylock kit (w/o keylock) Profalux Ronis
Kirk Castell 1 keylock Profalux Ronis 2 identical keylocks, 1 key Profalux Ronis 2 keylocks, different keys (MTZ2/3) Profalux Ronis
Chassis locking in “disconnected” position:VSPD - by keylocks Keylock kit (w/o keylock) Profalux Ronis
Kirk Castell 1 keylock Profalux Ronis 2 identical keylocks, 1 key Profalux Ronis 2 keylocks, different keys Profalux Ronis Optional connected/disconnected/test position locking
VPEC - door interlock On right-hand side of chassisOn left-hand side of chassis
VPOC - racking interlockIPA - cable-type door interlock VDC - mismatch protection VIVC - shutter position indication and locking for MTZ2/3 IBPO - racking interlock between crank and OFF pushbutton for MTZ2/3 People and property safety - Circuit ProtectionTCE - external sensor (CT) for neutral
Single sensor & Single wire (MTZ2/3)Double sensor & double wire (MTZ3)
TCW - external sensor for SGR protectionRectangular sensor for earth-leakage protection MTZ2/3 (470 x 160 mm)PTE - external voltage connectorPeople and property safety - Mechanical ProtectionCDP - escutcheon MTZ2/3CP - transparent cover for escutcheon MTZ2/3OP - blanking plate for escutcheon MTZ2/3CB - auxiliary terminal shield for chassis MTZ2/3People and property safety - Operation ProtectionKMT - grounding kit MTZ2/3Earthing switch kit for chassisDAE - automatic spring discharge before breaker removal for MTZ2/3 Power Availability and reliabilityVPS - Voltage power supplyAD - external power-supply module VBAT - battery moduleDigital ModuleEnergy per Phase Wave Form CaptureCircuit Breaker Restoration Circuit Breaker ReclosingCommonly Used Spare Parts* If you would like to order some spare parts, kindly indicate here. Please note that spare parts will be delivered separately. Mobile PowerPact by APCUSB CABLETransparent cover for micrologicDisplay for micrologicTest kits Mini test kit qtyFDM128Mounting accessories for FDM
To indicate your choice, check the applicable square boxesand enter the appropriate information in the rectangles
QuantityNumber of Devices* The quantity specified here will not affect the quantity of spare parts.
Basic ConfigurationMasterpact type MTZ2 MTZ3Rating (Masterkit 4000 A only with MTZ2) ASensor rating ACircuit breaker N1, H1, H2, L1 [1]
[1] L1: only for M08 to M20 drawout typeSwitch-disconnector NA, HAMicrologic X 2.0 5.0 6.0 7.0
X with Arc 2.0 5.0 6.0 7.0Number of poles 3 4Option: neutral on right side (MTZ2 only up to 3200A )Type of installation Fixed
Drawout with chassisDrawout without chassisChassis aloneChassis alone with contacts
Connection (rear only)
Top Horizontal VerticalBottom Horizontal Vertical
* For M40 4P fixed type, no possible mix between horizontal and vertical connectionsFor M63 drawout horizontal connection, consult us
Communication [2]Fixed ULP port only
ULP with Ethernet InterfaceULP with Ethernet Interface + Gateway
Drawable EIFEI/O Module[2] Consult Schneider Electric specialist to support and upgrade current installation with latest communicating solution
Design and installation simplificationInterphase barriers MTZ2 fixed, drawableOnly up to MTZ2 25 Upstream & Downstream
Operation Efficiency - SignalingOF - ON/OFF indication contacts* 4 OF 6 A-240 V AC (10 A-240 V AC and low level for NW) is supplied as standardAdditional 1 block of 4 OF Max. 2 Blocks qtyEF - combined “connected/closed” contacts* EF is only for MTZ2/3. Total number of EF can not exceed the number of additional OF
1 EF standard (6 A-240 V AC) qty1 EF low level qty
SDE - “fault-trip” indication contact* 1 SDE 6A - 240V AC is supplied as standardAdditional 1 SDE 6 A-240 V AC 1 SDE Low LevelProgrammable contacts 2 M2C contactsCarriage switches* Please refer to the catalogue for the maximum number of each carriage switchCE - “connected” position
Low Level qty 6 A - 240 V AC qty
CD - “disconnected” position
Low Level qty 6 A - 240 V AC qty
CT - “test” position
Low Level qty 6 A - 240 V AC qty
PF - “ready to close” contact
Low level6 A/240 VAC
CDM - mechanical operation counter MTZ2/3
C-4
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 50 fixed circuit breakersCircuit breakers
How to define ECOFIT Masterkit solutions?A complete Masterkit fixed circuit breaker is described by up to 8 catalogue numbers corresponding to:b the basic Masterpact MTZ2 or MTZ3 circuit breakerb a control unitb top and bottom connectionsb installation kitb escutcheon for MTZ2 40 and MTZ3 50b aux. wires strandb power isolation kit.A communication option, various auxiliaries and accessories may also be added.
Basic circuit breakerType N1
3P 4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 42 LV848000 LV848007MTZ2 10 1000 42 LV848014 LV848021MTZ2 12 1250 42 LV848028 LV848035MTZ2 16 1600 42 LV848042 LV848049Type H1
3P 4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 66 LV848001 LV848008MTZ2 10 1000 66 LV848015 LV848022MTZ2 12 1250 66 LV848029 LV848036MTZ2 16 1600 66 LV848043 LV848050MTZ2 20 2000 66 LV848057 LV848064MTZ2 25 2500 66 LV848070 LV848076
DB4
2140
0.ep
s
MTZ2 32 3200 66 LV848082 LV848087MTZ2 40 4000 66 LV848092 LV848097MTZ3 50 5000 100 LV848112 -Type H2
3P 4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 100 LV848002 LV848009MTZ2 10 1000 100 LV848016 LV848023MTZ2 12 1250 100 LV848030 LV848037MTZ2 16 1600 100 LV848044 LV848051MTZ2 20 2000 100 LV848058 LV848065MTZ2 25 2500 100 LV848071 LV848077
Basic circuit breaker y 4000 A. MTZ2 32 3200 100 LV848083 LV848088
DB4
2140
1.ep
s
MTZ2 40 4000 100 LV848093 LV848098MTZ3 50 5000 150 LV848113 -Option
Neutral on the right [1]
Micrologic X control unit“Class1 IEC 61557-12 certified power meter”
3P/4PMicrologic 2.0 X basic protection LV847280Micrologic 5.0 X selective protection LV847283Micrologic 6.0 X selective + earth-fault protection LV847288Micrologic 7.0 X [2] selective + earth-leakage protection LV847287
Basic circuit breaker u 4000 A.Digital modules option
3P/4PEnergy per phase LV850002Power restoration assistant LV850004Masterpact operation assistant LV850005Waveform capture on trip event LV850003
[1] Select a 4P basic circuit breaker with neutral on the right page C-21. All other catalogue numbers are unchanged.[2] Only for breaker up to 3200A
Auxiliaries and accessories:for fixed devices: see page C-17.for fixed or drawout devices: see page C-17.Switch-disconnector version: see page C-19.Source changeover assembly: see page C-17.
Communication optionULP port LV850061IFE Ethernet interface for LV breaker LV434010
Ethernet interface for LV breakers and gateway LV434011I/O application module LV434063
C-5
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 50 fixed circuit breakers and fixed switch-disconnectors
Connections
Vertical rear connectionDevice to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M12Type N1/NITop 3 x EF548952 4 x EF548952Bottom 3 x EF548952 4 x EF548952
Type H1/H2/HITop 3 x EF548953 4 x EF548953Bottom 3 x EF548953 4 x EF548953Masterpact M16Type N1/NI/H1/H2/HITop 3 x EF548953 4 x EF548953Bottom 3 x EF548953 4 x EF548953Masterpact M20 and M25Type N1/NI/H1/H2/HITop 3 x EF548956 4 x EF548956Bottom 3 x EF548956 4 x EF548956Masterpact M32Type H1/H2/HI Top 1 x EF548959 1 x EF548963Bottom 1 x EF548959 1 x EF548963Masterpact M40 Type H1/H2/HI Top 1 x EF548982 1 x EF548984 [1]
Bottom 1 x EF548982 included in Top refMasterpact M50 Type H1/H2/HI Top 1 x EF548986 NABottom 1 x EF548986 NA
Horizontal rear connectionDevice to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M12Type N1/NITop 3 x EF548951 4 x EF548951Bottom 3 x EF548964 4 x EF548964
Type H1/H2/HITop 3 x EF548954 4 x EF548954Bottom 3 x EF548965 4 x EF548965Masterpact M16Type N1/NI/H1/H2/HI Top 3 x EF548954 4 x EF548954Bottom 3 x EF548965 4 x EF548965Masterpact M20 and M25Type N1/NI/H1/H2/HITop 3 x EF548957 4 x EF548957Bottom 3 x EF548958 4 x EF548958Masterpact M32Type H1/H2/HI Top 1 x EF548962 1 x EF548960Bottom 1 x EF548961 1 x EF548960Masterpact M40 Type H1/H2/HI Top 1 x EF548980 1 x EF548983 [2]
Bottom 1 x EF548981 included in Top refMasterpact M50 Type H1/H2/HI Top 1 x EF548985 NABottom 1 x EF548985 NA
[1] Reference EF548984 includes Top and Bottom connections. For M40 no mix between EF548984 and EF548983
[2] Reference EF548983 includes Top and Bottom connections. For M40 no mix between EF548983 and EF548984
C-6
C
ECOFIT™ MasterkitMTZ2 08 to MTZ3 50 fixed circuit breakers and fixed switch-disconnectorsAccessories
Installation kitsDevice to be replaced
Kit to be ordered (includes installation guide) 3P 4P
Masterpact M08 to M32Type N1/NI/H1/H2/HI
1 x EF599927 1 x EF599927Masterpact M40Type H1/H2/HI
1 x EF599934 1 x EF599934Masterpact M50Type H1/H2/HI
1 x EF599935 NA
Power isolation kit (optional)Device to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M50Type N1/NI/H1/H2/HI
1 x EF548928 1 x EF548928
Auxiliaries wires strand Device to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M50Type N1/NI/H1/H2/HI
1 x EF548930 [1] 1 x EF548930 [1]
Escutcheon1x LV84601SP
Installation guide (included as standard in the installation kits)1x EF599100
[1] Auxiliaries 24 wires strand 08/63H Fix/Do
C-7
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 50 fixed circuit breakers Indication contacts and remote operation
Indication contactsON/OFF indication contacts (OF)
DB4
0431
4.ep
s Block of 4 changeover contacts (6 A - 240 V) 1 block (standard)1 additional block of 4 contacts (2 max.) LV848198
“Fault trip” indication contacts (SDE)
DB4
0431
5.ep
s Changeover contact (6 A - 240 V) 1 (standard)1 additional SDE (6 A - 240 V) LV8482001 additional low-level SDE LV848201
Programmable contacts (programmed via Micrologic X control unit)
DB4
0437
0.ep
s 2 contacts M2C (5 A - 240 V) LV847403
Remote operation“Ready to close” contact (1 max.)
DB4
0431
8.ep
s PF1 changeover contact (5 A - 240 V) LV8473421 low-level changeover contact LV847343
Electrical closing pushbutton
DB4
0431
9.ep
s BPFE1 pushbutton LV848534
Remote reset after fault trip
DB4
0431
5.ep
s Electrical reset RES110/130 V AC LV848202220/240 V AC LV848203Automatic reset RARAdaptation LV847346
C-8
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 50 fixed circuit breakers Remote operation
Remote ON/OFFGear motor
DB4
0431
6.ep
s MCHAC 50/60 Hz 48 V LV848207
100/130 V LV848211200/240 V LV848212250/277 V LV848213380/415 V LV848214440/480 V LV848215
DC 24/30 V LV84820648/60 V LV848207100/130 V LV848208200/250 V LV848209
Instantaneous voltage releases
DB4
0431
7.ep
s
Closing release Opening releaseStandard XF MXAC 50/60 Hz 24/30 V DC, 24 V AC LV847350 LV847360DC 48/60 V DC, 48 V AC LV847351 LV847361
100/130 V AC/DC LV847352 LV847362200/250 V AC/DC LV847353 LV847363277 V AC LV847354 LV847364380/480 V AC LV847355 LV847365
Diagnostics & Communicating XF diag & com MX diag & comAC 50/60 Hz 24/30 V DC, 24 V AC LV847311 LV847321DC 48/60 V DC, 48 V AC LV847312 LV847322
100/130 V AC/DC LV847313 LV847323200/250 V AC/DC LV847314 LV847324277 V AC LV847315 LV847325380/480 V AC LV847316 LV847326
Opening releaseStandard MNAC 50/60 Hz 24/30 V DC, 24 V AC LV847380DC 48/60 V DC, 48 V AC LV847381
100/130 V AC/DC LV847382200/250 V AC/DC LV847383380/480 V AC LV847385
Diagnostic MN diagAC 50/60 Hz 24/30 V DC, 24 V AC LV836700DC 48/60 V DC, 48 V AC LV836701
100/130 V AC/DC LV836702200/250 V AC/DC LV836703380/480 V AC LV836704
Remote trippingInstantaneous voltage release
DB4
0431
7.ep
s 2nd MXAC 50/60 Hz 24/30 V DC, 24 V AC LV847370DC 48/60 V DC, 48 V AC LV847371
100/130 V AC/DC LV847372200/250 V AC/DC LV847373277 V AC LV847374380/480 V AC LV847375
MN delay unit
DB4
0432
0.ep
s R (non-adjustable) Rr (adjustable)AC 50/60 Hz 48/60 V AC/DC - LV833680SPDC 100/130 V AC/DC LV833684SP LV833681SP
200/250 V AC/DC LV833685SP LV833682SP380/480 V AC/DC - LV833683SP
C-9
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersCircuit breakers
How to define ECOFIT Masterkit solutions?A complete Masterkit withdrawablecircuit breaker is described by up to 11 catalogue numbers corresponding to:b the basic Masterpact MTZ circuit breakerb a control unitb a chassisb top and bottom connectionsb installation kitb aux wires strandsb escutcheon for MTZ2 40 and MTZ3 50/63b power isolation kitb riser block for MTZ2 40 4P Drawout.A communication option, various auxiliaries and accessories may also be added.
Basic circuit breaker3P 4P
Type N1In (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 42 LV848230 LV848237MTZ2 10 1000 42 LV848244 LV848251MTZ2 12 1250 42 LV848258 LV848265MTZ2 16 1600 42 LV848272 LV848279Type H1
In (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % IcuMTZ2 08 800 66 LV848231 LV848238MTZ2 10 1000 66 LV848245 LV848252MTZ2 12 1250 66 LV848259 LV848266MTZ2 16 1600 66 LV848273 LV848280MTZ2 20 2000 66 LV848287 LV848294MTZ2 25 2500 66 LV848300 LV848306MTZ2 32 3200 66 LV848312 LV848317MTZ2 40 4000 66 LV848322 LV848327
DB4
2140
2.ep
s MTZ3 50 5000 100 LV848342 LV848345MTZ3 63 6300 100 LV848348 LV848351Type H2
In (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % IcuMTZ2 08 800 100 LV848232 LV848239MTZ2 10 1000 100 LV848246 LV848253MTZ2 12 1250 100 LV848260 LV848267MTZ2 16 1600 100 LV848274 LV848281MTZ2 20 2000 100 LV848288 LV848295MTZ2 25 2500 100 LV848301 LV848307MTZ2 32 3200 100 LV848313 LV848318MTZ2 40 4000 100 LV848323 LV848328MTZ3 50 5000 150 LV848343 LV848346MTZ3 63 6300 150 LV848349 LV848352
Basic circuit breaker + chassis y 4000 A
DB4
2140
3.ep
s Type L1In (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 150 LV848233 LV848240MTZ2 10 1000 150 LV848247 LV848254MTZ2 12 1250 150 LV848261 LV848268MTZ2 16 1600 150 LV848275 LV848282MTZ2 20 2000 150 LV848290 LV848297Option
Neutral on the right [1]
Micrologic X control unitBasic circuit breaker + chassis u 4000 A “Class1 IEC 61557-12 certified power meter"
3P/4PMicrologic 2.0 X basic protection LV848498Micrologic 5.0 X selective protection LV848499Micrologic 6.0 X selective + earth-fault protection LV848500Micrologic 7.0 X[2] selective + earth-leakage protection LV848362
Digital modules option3P/4P
Energy per phase LV850002Power restoration assistant LV850004Masterpact operation assistant LV850005Waveform capture on trip event LV850003
[1] Select a 4P basic circuit breaker with neutral on the rightpage C-21. All other catalogue numbers are unchanged.[2] Only for breaker up to 3200 A.
Grounding kitGrounding kit for Masterpact MTZ2/MTZ3 drawout LV848559
C-10
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersChassis
DB4
2140
4.ep
s Chassis3P 4P
For type N11600 A LV848392 LV8484042000 A LV848393 LV848405For type H1
800-1600 A LV848392 LV848404For type H2
800-1600 A LV848393 LV848405For type H1/H2
Chassis y 4000 A 2000 A LV848393 LV8484052500 A LV848394 LV8484063200 A LV848395 LV8484074000 A LV848396 LV8484084000/6300 A LV848397 LV848409For type L1
800/1600 A LV848399 LV8484112000 A LV848400 LV848412
Ethernet communication optionChassis + Circuit breaker (ULP)
Auxiliaries and accessories: b for drawout devices: see page C-13 b for fixed or drawout devices: see page C-17.
Switch-disconnector version: see page C-19.Source changeover assembly: see page C-17.
ULP port Standard StandardEIFE Embedded Ethernet interface for LV breaker
LV851200
IFE Ethernet interface for LV breaker
LV434010
Ethernet interface for LV breakers and gateway
LV434011
I/O application module LV434063
C-11
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakers and drawout switch-disconnectors
ConnectionsVertical rear connectionDevice to be replaced
Connection to be ordered3P 4P
Masterpact M08 to M12Type N1/NITop 3 x EF548966 4 x EF548966Bottom 3 x EF548966 4 x EF548966
Type H1/H2/HI/L1Top 3 x EF548969 4 x EF548969Bottom 3 x EF548969 4 x EF548969Masterpact M16Type N1/NI/H1/H2/HI/L1 Top 3 x EF548969 4 x EF548969Bottom 3 x EF548969 4 x EF548969Masterpact M20 and M25Type N1/NI/H1/H2/HITop 3 x EF548970 4 x EF548970Bottom 3 x EF548970 4 x EF548970Masterpact M32 and M20Type H1/H2/HI L1Top 1 x EF548974 1 x EF548978Bottom 1 x EF548974 1 x EF548978Masterpact M40 Type H1/H2/HITop 1 x EF548989 1 x EF548992Bottom 1 x EF548989 1 x EF548993Masterpact M50 Type H1/H2/HI Top 1 x EF548995 1 x EF548997Bottom 1 x EF548995 1 x EF548998Masterpact M63 Type H1/H2/HI Top 1 x EF548940 1 x EF548943Bottom 1 x EF548940 1 x EF548944
Horizontal rear connectionDevice to be replaced
Connection to be ordered3P 4P
Masterpact M08 to M12Type N1/NITop 3 x EF548951 4 x EF548951Bottom 3 x EF548964 4 x EF548964
Type H1/H2/HI/L1Top 3 x EF548954 4 x EF548954Bottom 3 x EF548965 4 x EF548965Masterpact M16Type N1/NI/H1/H2/HI/L1 Top 3 x EF548954 4 x EF548954Bottom 3 x EF548965 4 x EF548965Masterpact M20 and M25Type N1/NI/H1/H2/HITop 3 x EF548957 4 x EF548957Bottom 3 x EF548958 4 x EF548958Masterpact M32 and M20 neutral on left-hand sideType H1/H2/HI L1Top 1 x EF548973 1 x EF548976Bottom 1 x EF548973 1 x EF548977Masterpact M32 and M20 neutral on right-hand sideType H1/H2/HI L1Top 1 x EF548973 1 x EF548977Bottom 1 x EF548973 1 x EF548976Masterpact M40 Type H1/H2/HITop 1 x EF548987 1 x EF548990Bottom 1 x EF548988 1 x EF548991Masterpact M50 Type H1/H2/HI Top 1 x EF548994 1 x EF548996Bottom 1 x EF548994 1 x EF548996
C-12
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakers and drawout switch-disconnectorsAccessories
Installation kitsDevice to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M32Type N1/NI/H1/H2/HI
1 x EF599927 1 x EF599927Masterpact M40Type H1/H2/HI
1 x EF599934 1 x EF599934Masterpact M50Type H1/H2/HI
1 x EF599935 1 x EF599935Masterpact M63Type H1/H2/HI
1 x EF599938 1 x EF599938
Riser blockDevice to be replaced
Kit to be ordered3P 4P
Masterpact M40Type H1/H2/HI
NA 1 x EF548932
Power isolation kit (optional)Device to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M63Type N1/NI/H1/H2/HI
1 x EF548928 1 x EF548928
Auxiliaries wires strand Device to be replaced
Kit to be ordered3P 4P
Masterpact M08 to M50Type N1/NI/H1/H2/HI
1 x EF548929 [1] 1 x EF548929 [1]
1 x EF548930 [2] 1 x EF548930 [2]
Escutcheon1x LV848603SP
Installation guide (included as standard in the installation kits)1x EF599100
[1] Auxiliaries 12 wires strand 08/63H Do[2] Auxiliaries 24 wires strand 08/63H Fix/Do
C-13
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersChassis locking and accessories
Chassis locking“Disconnected” position locking
DB4
0432
5.ep
s By padlocksVCPO Standard
By Profalux keylocksProfalux 1 lock with 1 key + adaptation kit LV848568
2 locks 1 key + adaptation kit LV8485692 locks 2 different keys + adaptation kit LV848570
By Ronis keylocksRonis 1 lock with 1 key + adaptation kit LV848572
2 locks 1 key + adaptation kit LV8485732 locks 2 different keys + adaptation kit LV848574
Optional disconnected/test/connected position locking LV833779Adaptation kit (without keylock):
adaptation kit Profalux / Ronis LV848564SPadaptation kit Castell LV848565SPadaptation kit Kirk LV848566SP
Door interlock (1 part)
DB4
0432
6.ep
s Right-hand side of chassis LV848579SPLeft-hand side of chassis LV848580SP
Racking interlock
DB4
0432
7.ep
s
1 part LV848582
Racking interlock between crank and OFF pushbutton1 part LV848585
Automatic spring discharge before breaker removal
DB4
0432
8.ep
s 1 part LV848554
Breaker mismatch protection
DB4
0432
9.ep
s Breaker mismatch protection VDC LV833767SP
C-14
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersChassis locking and accessories
Chassis accessoriesArc chute cover
DB4
0433
0.ep
s 3P/4P Standard
Auxiliary terminal shield (CB)
DB4
0433
1.ep
s 800/4000 A 3P LV8485954P LV848596
4000/6300 A 3P LV8485974P LV848598
Safety shutters + locking block
DB4
0433
2.ep
s 800/4000 A 3P Standard4P Standard
4000/6300 A 3P Standard4P Standard
Shutter locking block (for remplacement)
DB4
0433
3.ep
s 2 parts for 800/4000 A LV848591SP
Front face shutter position indication and locking
DB4
0437
4.ep
s 800/4000 A 3P/4P LV8485924000/6300 A 3P LV848593
4P LV848594
C-15
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersIndication contacts and remote operation
Indication contactsON/OFF indication contacts (OF)
DB4
0432
1.ep
s Block of 4 changeover contacts (6 A - 240 V) 1 block (standard)1 additional block of 4 contacts (2 max.) LV848468
Combined closed / connected contacts for use with 1 auxiliary contact
DB4
0432
2.ep
s 1 contact (5 A - 240 V) (8 max.) LV848477or 1 low-level contact (8 max.) LV848478
“Fault trip” indication contacts (SDE)
DB4
0432
3.ep
s Changeover contact (6 A - 240 V) 1 (standard)1 additional SDE (6 A - 240 V) LV848475or 1 additional low-level SDE LV848476
Programmable contacts (programmed via Micrologic X control unit)
DB4
0437
5.ep
s 2 contacts M2C (5 A - 240 V) LV848382
Carriage switches (connected / disconnected / test position)
DB4
0432
4.ep
s Changeover contacts (8 A - 240 V)1 connected position contact (3 max.) LV8337511 test position contact (3 max.) LV8337521 disconnected position contact (3 max.) LV833753
and/or low-level changeover contacts1 connected position contact (3 max.) LV8337541 test position contact (3 max.) LV8337551 disconnected position contact (3 max.) LV833756Actuator for additional carriage switches LV848560SP
Auxiliary terminals for chassis alone3 wire terminal (30 parts) LV847898SP6 wire terminal (10 parts) LV847899SPJumpers (10 parts) LV847900SP
Remote operation“Ready to close” contact (1 max.)
DB4
0437
9.ep
s PF1 changeover contact (5 A - 240 V) LV8484691 low-level changeover contact LV848470
Electrical closing pushbutton
DB4
0431
9.ep
s BPFE1 pushbutton LV848534
Remote reset after fault tripElectrical reset RES110/130 V AC LV848472220/240 V AC LV848473Automatic reset RARAdaptation LV847346
C-16
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout circuit breakersRemote operation
Remote ON/OFFGear motor
DB4
0431
6.ep
s MCHAC 50/60 Hz 48 V LV848522
100/130 V LV848526200/240 V LV848527250/277 V LV848528380/415 V LV848529440/480 V LV848530
DC 24/30 V LV84852148/60 V LV848522100/130 V LV848523200/250 V LV848524
Instantaneous voltage releases
DB4
0431
7.ep
s
Closing release Opening releaseStandard XF MXAC 50/60 Hz 24/30 V DC, 24 V AC LV848481 LV848491DC 48/60 V DC, 48 V AC LV848482 LV848492
100/130 V AC/DC LV848483 LV848493200/250 V AC/DC LV848484 LV848494277 V AC LV848485 LV848495380/480 V AC LV848486 LV848496
Diagnostic & Communicating XF diag & com MX diag & comAC 50/60 Hz 24/30 V DC, 24 V AC LV848449 LV848458DC 48/60 V DC, 48 V AC LV848450 LV848459
100/130 V AC/DC LV848451 LV848460200/250 V AC/DC LV848452 LV848461277 V AC LV848453 LV848462380/480 V AC LV848454 LV848463
Opening releaseStandard MNAC 50/60 Hz 24/30 V DC, 24 V AC LV848501DC 48/60 V DC, 48 V AC LV848502
100/130 V AC/DC LV848503200/250 V AC/DC LV848504380/480 V AC LV848506
Diagnostic MN diagAC 50/60 Hz 24/30 V DC, 24 V AC LV836705DC 48/60 V DC, 48 V AC LV836706
100/130 V AC/DC LV836707200/250 V AC/DC LV836708380/480 V AC LV836709
Remote trippingInstantaneous voltage release
DB4
0431
7.ep
s 2nd MXAC 50/60 Hz 24/30 V DC, 24 V AC LV848511DC 48/60 V DC, 48 V AC LV848512
100/130 V AC/DC LV848513200/250 V AC/DC LV848514277 V AC LV848515380/480 V AC LV848516
MN delay unit
DB4
0432
0.ep
s R (non-adjustable) Rr (adjustable)AC 50/60 Hz 48/60 V AC/DC - LV833680SPDC 100/130 V AC/DC LV833684SP LV833681SP
200/250 V AC/DC LV833685SP LV833682SP380/480 V AC/DC - LV833683SP
C-17
C
ECOFIT™ Masterkit
Accessories for MTZ2 08 to MTZ3 63 fixed and drawout circuit breakers
Circuit breaker locking Pushbutton locking device
DB4
0433
7.ep
s By padlocks LV848536
OFF position locking
DB4
0433
8.ep
s By padlocksVCPO LV848539
By Profalux keylocksProfalux 1 lock with 1 key + adaptation kit LV848545
2 locks 1 key + adaptation kit LV8485462 locks 2 different keys + adaptation kit LV848547
By Ronis keylocksRonis 1 lock with 1 key + adaptation kit LV848549
2 locks 1 key + adaptation kit LV8485502 locks 2 different keys + adaptation kit LV848551
Adaptation kit (without keylock):
adaptation kit Profalux / Ronis LV848541SPadaptation kit Kirk LV848542SPadaptation kit Castell LV848543SP
Cable-type door interlock1 complete assembly for Masterpact MTZ2/MTZ3 fixed or drawout device LV848614SP
Mechanical interlocking for source changeoverInterlocking of 2 devices using connecting rods
DB4
2140
5.ep
s Complete assembly with 2 adaptation fixtures + rods1 set of 2 adaptation fixtures for Masterpact MTZ2 or MTZ3 fixed or drawout device LV847930SP1 set of 2 interlocking rods LV833210SPNote: Can be used with 1 MTZ2/3 fixed + 1 MTZ2/3 drawout.
Interlocking of 2 devices using cables [1]
DB4
2140
6.ep
s
Choose 2 adaptation fixtures (1 for each device) + 1 set of cables 1 adaptation fixture for Masterpact MTZ2/3 fixed devices LV847926SP1 adaptation fixture for Masterpact MTZ2/3 drawout devices LV847926SP1 set of 2 cables of 2.5 m LV833209SP[1] Can be used with any combination of MTZ, fixed or drawout devices.
Interlocking of 3 devices using cables
DB4
2140
7.ep
s
Choose 1 interlocking kit (including 3 adaptation fixtures + cables) 3 sources, only 1 device closed, fixed or drawout devices LV848610SP2 sources + 1 coupling, fixed or drawout devices LV848609SP2 normal + 1 replacement source, fixed or drawout devices LV848608SP
Other circuit breaker accessoriesMechanical operation counter
DB1
2561
7.ep
s Operation counter CDM LV848535
Escutcheon and accessories
DB4
2141
5.ep
s
DB4
0434
0.ep
s
DB4
0434
1.ep
s Fixed DrawoutEscutcheon LV848601SP LV848603SPTransparent cover IP54 LV848604SPEscutcheon blanking plate LV848605SP LV848605SP
Escutcheon Cover Blanking plate
C-18
C
ECOFIT™ Masterkit
Accessories for MTZ2 08 to MTZ3 63 fixed and drawout circuit breakers
Accessories for Micrologic X control unitsExternal sensorsExternal sensor for earth-fault protection (TCE)
DB4
2134
9.ai
Sensor rating 400/2000 A LV834035SP1000/4000 A LV834036SP4000/6300 A (MTZ3) LV848182SP
Single sensor kit 2000/6300 A LV8489043 layer bus 2000 A LV848905
Rectangular sensor for earth-leakage protection
DB4
0438
2.ep
s 470 mm x 160 mm In max. 3200 A LV833574SP
Source ground return (SGR) earth fault protection
DB4
0438
2.ep
s External sensor (SGR) LV833579SPMDGF summing module LV848891SP
Voltage measurement input (for breakers supplied via bottom terminals)
DB1
2564
2.ep
s Voltage measurement input Fixed LV847506Drawout LV848533
Voltage power supply module (VPS) for Micrologic X
DB4
2140
8.ep
s LV850060
Zone Selective Interlocking option for Micrologic XZSI Standard
External power supply module (AD)
DB1
0536
0.ep
s 24/30 V DC 5444048/60 V DC 54441100/125 V DC 54442110/130 V AC 54443200/240 V AC 54444380/415 V AC 54445
Battery module (BAT)
L3
G1
AD 220A
L4
G2
Input
24VDC
Output
24VDCD
B404
384.
eps 1 battery 24 V 54446
Test and commisionning equipmentUSB Cable (miniUSB/USB) for Micrologic X
DB4
2140
9.ep
s LV850067SP
Mobile Powerpack for Micrologic X (by APC)
DB4
2141
0.ep
s LV850055SP
Special settingsSensor rating to be specified when orderingRating MTZ2 08 MTZ2 10 MTZ2 12 MTZ2 16 MTZ2 20 MTZ2 25 MTZ2 32400 b b630 b b b800 b b b1000 b b b1250 b b b1600 b b b2000 b b2500 b3200Rating MTZ2 40 MTZ3 40 MTZ3 50 MTZ3 632000 b b2500 b b b3200 b b b b4000 b b5000 b6300
C-19
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 50 fixed switch-disconnectors Switch-disconnectors and connections
How to define ECOFIT Masterkit solutions?A complete Masterkit fixed switch-disconnector is described by up to 7 catalogue numbers corresponding to:b the basic Masterpact MTZ2 or MTZ3 switch-disconnectorb top and bottom connectionsb installation kitb escutcheon for MTZ2 40 and MTZ3 50b aux. wires strandb power isolation kit.A communication option, various auxiliaries and accessories may also be added.
Basic switch-disconnectorType NA
3P 4PIn (A at 40 °C) Icm (kA peak for U = 220/690 V)
MTZ2 08 800 88 LV848004 LV848011MTZ2 10 1000 88 LV848018 LV848025MTZ2 12 1250 88 LV848032 LV848039MTZ2 16 1600 88 LV848046 LV848053
Type HA3P 4P
In (A at 40 °C) Icm (kA peak for U = 220/690 V)MTZ2 08 800 145 LV848005 LV848012MTZ2 10 1000 145 LV848019 LV848026MTZ2 12 1250 145 LV848033 LV848040MTZ2 16 1600 145 LV848047 LV848054MTZ2 20 2000 145 LV848061 LV848068MTZ2 25 2500 145 LV848074 LV848080MTZ2 32 3200 145 LV848085 LV848090
DB4
2141
1.ep
s
Basic switch-disconnector y 4000 A.
DB4
2141
2.ep
s
Basic switch-disconnector u 4000 A.
MTZ2 40 4000 145 LV848095 LV848100MTZ3 50 5000 187 LV848114
Connections see page C-5
Masterkit accessories see page C-6
Auxiliaries and accessories:b for fixed devices: see page C-6b for fixed or drawout devices: see page C-17. b Source changeover assembly: see page C-17.Version : 1.0 - 20 février 2017
C-20
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ3 63 drawout switch-disconnectors Switch-disconnectors and connections
How to define ECOFIT Masterkit solutions?Masterkit drawout switch-disconnector is described by up to 10 catalogue numbers corresponding to:b the basic Masterpact MTZ switch-disconnectorb a chassisb top and bottom connectionsb installation kitb aux. wires strandsb escutcheon for MTZ2 40 and MTZ3 50/63b power isolation kitb riser block for MTZ2 40 4P Drawout .A communication option, various auxiliaries and accessories may also be added.
Basic switch-disconnectorType NA
3P 4PIn (A at 40 °C) Icm (kA peak for U = 220/690 V)
MTZ2 08 800 88 LV848234 LV848241MTZ2 10 1000 88 LV848248 LV848255MTZ2 12 1250 88 LV848262 LV848269MTZ2 16 1600 88 LV848276 LV848283Type HA
3P 4PIn (A at 40 °C) Icm (kA peak for U = 220/690 V)
MTZ2 08 800 145 LV848235 LV848242MTZ2 10 1000 145 LV848249 LV848256MTZ2 12 1250 145 LV848263 LV848270MTZ2 16 1600 145 LV848277 LV848284MTZ2 20 2000 145 LV848291 LV848298MTZ2 25 2500 145 LV848304 LV848310MTZ2 32 3200 145 LV848315 LV848320MTZ2 40 4000 145 LV848325 LV848330MTZ3 50 5000 187 LV848344 LV848347MTZ3 63 6300 187 LV848350 LV848353
ChassisType NA
Auxiliaries and accessories: b for fixed devices: see page C-12 b for fixed or drawout devices: see page C-17. b Source changeover assembly: see page C-17.
3P 4P1600 A LV848392 LV848404Type HA
3P 4P800-1600 A LV848392 LV8484042000 A LV848393 LV8484052500 A LV848394 LV8484063200 A LV848395 LV8484074000 A LV848396 LV8484085000/6300 A (MTZ3) LV848397 LV848409
Connections see page C-11
Masterkit accessories see page C-12
DB4
2141
3.ep
s
Basic switch-disconnector + chassis y 4000 A.
DB4
2141
4.ep
s
Basic switch-disconnector + chassis u 4000 A.
C-21
C
ECOFIT™ Masterkit
MTZ2 08 to MTZ2 32 circuit breakers with neutral on the right
Circuit breakersHow to define ECOFIT Masterkit solutions?A 4 pole Masterkit circuit breaker with neutral on the right is described by the same catalogue numbers as a standard Masterpact MTZ2 4 pole one, except for the basic Masterpact MTZ2 circuit breaker, which is specific.
Fixed circuit breakers with neutral on the rightType H1
4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 66 LV848183MTZ2 10 1000 66 LV848184MTZ2 12 1250 66 LV848185MTZ2 16 1600 66 LV848186MTZ2 20 2000 66 LV848060MTZ2 25 2500 66 LV848073MTZ2 32 3200 66 LV848187Type H2
4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 100 LV848177MTZ2 10 1000 100 LV848178MTZ2 12 1250 100 LV848179MTZ2 16 1600 100 LV848180MTZ2 20 2000 100 LV848067MTZ2 25 2500 100 LV848079MTZ2 32 3200 100 LV848181
Drawout circuit breakers with neutral on the rightType H1
4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 66 LV848226MTZ2 10 1000 66 LV848227MTZ2 12 1250 66 LV848228MTZ2 16 1600 66 LV848229MTZ2 20 2000 66 LV848436MTZ2 25 2500 66 LV848303MTZ2 32 3200 66 LV848437Type H2
4PIn (A at 40 °C) Icu (kA for U = 220/440 V) - Ics = 100 % Icu
MTZ2 08 800 100 LV848426MTZ2 10 1000 100 LV848427MTZ2 12 1250 100 LV848428MTZ2 16 1600 100 LV848429MTZ2 20 2000 100 LV848438MTZ2 25 2500 100 LV848309MTZ2 32 3200 100 LV848439
APPENDIX:APPENDIX:
SPARE PARTSSPARE PARTS
D-1
D
Appendix: Masterpact MTZ spare parts
Micrologic X control unit, communication option, accessories .................................................................D-2
Remote operation ....................................................................D-3
Chassis locking and accessories ......................................D-4
Clusters .......................................................................................D-5
Circuit breaker locking and accessories ........................D-6
Mechanical interlocking for source changeover .........D-7
Indication contacts .................................................................D-8
Monitoring and control, Ethernet gateway .....................D-9
Appendix: Masterpact MTZ2/3 spare parts
D-2
D
Micrologic X control unit, communication option, accessories
Replacement parts for Micrologic X control unitsMicrologic X embedded display (EHMI)
DB4
2142
3.ep
s Micrologic X embedded display & wireless card LV850054SP
Micrologic X Battery + Transparent cover
DB4
2142
4.ep
s Battery (1 part) LV833593SPTransparent Cover (1 part) for Micrologic X LV850053SP
Voltage power supply module (VPS) for Micrologic X
DB4
2140
8.ep
s Voltage power supply module (VPS) for Micrologic X LV850060SP
Communication option
DB4
2142
5.ep
s
DB4
2142
6.ep
s
ETH1
ETH2
DB4
2142
7.ep
s
DB4
2142
8.ep
s
EIFE Embedded Ethernet interface for LV breaker LV851200SPIFE Ethernet interface LV breaker LV434010
Ethernet interface for LV breakers and gateway LV434011I/O application module LV434063Microswitches for MTZ2/3 LV847905SP
AccessoriesExternal sensorsExternal sensor for earth-fault protection (TCE) / 1 part
DB4
2134
9.ai
Sensor rating 400/2000 A LV834035SP1000/4000 A LV834036SP4000/6300 A (MTZ3) LV848182SP
Single sensor kit 2000/6300 A LV8489043 layer bus 2000 A LV848905
Source ground return (SGR) earth-fault protection / 1 part
DB40
4382
_1.ep
s
External sensor (SGR) LV833579SPMDGF summing module LV848891SP
Rectangular sensor for earth-leakage protection + Vigi cable / 1 part (up to 3200 A)
DB40
4382
_1.ep
s
280 mm x 115 mm LV833573SP470 mm x 160 mm LV833574SP
External power supply module (AD) / 1 part
DB10
5360
_1.ep
s 24-30 V DC 5444048-60 V DC 54441100-125 V DC 54442110-130 V AC 54443200-240 V AC 54444380-415 V AC 54445
Battery module (BAT) / 1 part
L3
G1
AD 220A
L4
G2
Input
24VDC
Output
24VDC
DB40
4384
_1.ep
s 1 battery 24 V DC 54446
USB Cable (miniUSB/USB) for Micrologic X / 1 part
DB4
2140
9.ep
s USB Cable (miniUSB/USB) for Micrologic X / 1 part LV850067SP
Mobile Powerpack for Micrologic X (by APC) / 1 part
DB4
2141
0.ep
s Mobile Powerpack for Micrologic X (by APC) / 1 part LV850055SP
Appendix: Masterpact MTZ2/3 spare parts
D-3
D
Remote operation
Remote operationGear motor
DB4
0431
6.ep
s MCH (1 part)AC 50/60 Hz 48 V LV847889SP
100/130 V LV847893SP200/240 V LV847894SP277/415 V LV847895SP440/480 V LV847896SP+ resistor LV847897SP
DC 24/30 V LV847888SP
. DB4
0439
8.ep
s
DB4
0439
9.ep
s 48/60 V LV847889SP100/125 V LV847890SP200/250 V LV847891SP
Terminal block (1 part) For fixed circuit breaker LV847074SPFor drawout circuit breaker LV847849SP
Fixed. Drawout.Closing and opening release (XF or MX)
DB4
0440
0.ep
s Standard coil (1 part)AC 50/60 HzDC
24/30 V DC, 24 V AC LV833659SP48/60 V DC, 48 V AC LV833660SP100/130 V AC/DC LV833661SP200/250 V AC/DC LV833662SP277 V AC LV833663SP380/480 V AC LV833664SP
Diagnostics & Communicating coil (1 part) [1]
AC 50/60 HzDC
24/30 V DC, 24 V AC LV833033SP48/60 V DC, 48 V AC LV833034SP100/130 V AC/DC LV833035SP200/250 V AC/DC LV833036SP
DB4
0439
9.ep
s 277 V AC LV833037SP
DB4
0439
8.ep
s 380/480 V AC LV833038SPWiring kit for diag & com coil LV847904
Terminal block (1 part) For fixed circuit breaker LV847074SPFor drawout circuit breaker LV847849SP
Fixed. Drawout.Undervoltage release MN
DB4
0440
0.ep
s Undervoltage release (1 part)AC 50/60 Hz 24/30 V DC, 24 V AC LV833668SPDC 48/60 V DC, 48 V AC LV833669SP
100/130 V AC/DC LV833670SP200/250 V AC/DC LV833671SP380/480 V AC LV833673SP
Diagnostics coil (1 part) [1]
AC 50/60 Hz 24/30 V DC, 24 V AC LV833668SPDC 48/60 V DC, 48 V AC LV833669SP
100/130 V AC/DC LV833670SP200/250 V AC/DC LV833671SP
DB4
0439
8.ep
s
DB4
0439
9.ep
s 380/480 V AC LV833673SPWiring kit for diag & com coil LV847904
Terminal block (1 part) For fixed circuit breaker LV847074SPFor drawout circuit breaker LV847849SP
Fixed. Drawout.MN delay unit
DB40
4320
_1.ep
s MN delay unit (1 part)R (non-adjustable) Rr (adjustable)
AC 50/60 Hz 48/60 V AC/DC LV833680SPDC 100/130 V AC/DC LV833684SP LV833681SP
200/250 V AC/DC LV833685SP LV833682SP380/480 V AC/DC LV833683SP
[1] Diagnostics & Communicating coils (MX/XF/MN) requires additionally the isolation module if isnt installed in breaker -1 module by breaker.
Appendix: Masterpact MTZ2/3 spare parts
D-4
D
Chassis locking and accessories
Chassis locking“Disconnected” position locking / 1 part
DB4
0432
5_1.
eps By padlocks
VCPO Standard
By Profalux keylocksProfalux 1 lock with 1 key + adaptation kit LV864934SP
2 locks 1 key + adaptation kit LV864935SP2 locks 2 different keys + adaptation kit LV864936SP
1 keylock Profalux (without adaptation kit):
identical key not identified combination LV833173SPidentical key identified 215470 combination LV833174SPidentical key identified 215471 combination LV833175SP
By Ronis keylocksRonis 1 lock with 1 key + adaptation kit LV864937SP
2 locks 1 key + adaptation kit LV864938SP2 locks 2 different keys + adaptation kit LV864939SP
1 keylock Ronis (without adaptation kit):
identical key not identified combination LV833189SPidentical key identified EL24135 combination LV833190SPidentical key identified EL24153 combination LV833191SPidentical key identified EL24315 combination LV833192SP
Adaptation kit (without keylock):
adaptation kit Profalux / Ronis LV848564SPadaptation kit Kirk LV848565SPadaptation kit Castell LV848566SP
Door interlock / 1 part
DB4
0432
6_1.
eps
Right and left-hand side of chassis (VPECD or VPECG) LV847914SP
Racking interlock
DB40
4327
_1.e
ps
5 parts LV864940SP
Breaker mismatch protection / 1 part
DB4
0432
9_2.
eps Breaker mismatch protection (VDC) LV833767SP
Chassis accessoriesAuxiliary terminal shield (CB) / 1 part
DB4
0433
1_1.
eps MTZ2 800/4000 A 3P LV864942SP
4P LV848596SPMTZ3 4000/6300 A 3P LV848597SP
4P LV848598SP
Safety shutters + locking block / 1 part
DB4
0433
2_1.
eps MTZ2 800/4000 A 3P LV848721SP
4P LV848723SPMTZ3 4000/6300 A 3P LV848722SP
4P LV848724SP
Shutter locking block (for replacement) / 1 part
DB40
4333
_1.e
ps 2 parts for 800/4000 A LV848591SP
Earthing kit for chassis 3P 4PTypes for N1/H1/NA/HA
LV848433SP LV848434SPNote: the installation manual is enclosed.
Appendix: Masterpact MTZ2/3 spare parts
D-5
D
Clusters
Clusters
DB4
0328
0_1.
eps 1 disconnecting contact cluster for chassis (see table below) (part 1) LV864906SP
Table : number of clusters required for the different chassis modelsChassis rating (A)
Masterpact MTZ2/3 3P Masterpact MTZ2/3 4PN1 H1/H2 H3 L1 N1 H1/H2 H3 L1
630 6 12 24 8 16 32800 6 12 24 8 16 321000 6 12 24 8 16 321250 6 12 24 8 16 321600 12 12 24 16 16 322000 24 24 42 32 32 562500 24 24 32 323200 36 36 48 484000 42 42 56 564000b 72 965000 72 966300 72 96Note: the minimum order is 6 parts.
DB4
1799
0.ep
s
Set of 2 clusters fitters for 2 and 3 clusters 47554
DB4
1800
7.ep
s
Racking handle
DB40
3281
_1.e
ps Racking handle LV847944SP
Appendix: Masterpact MTZ2/3 spare parts
D-6
D
Circuit breaker locking and accessories
Circuit breaker lockingPushbutton locking device / 1 part
DB4
0433
7_2.
eps By padlocks LV848536SP
OFF position locking / 1 part
DB4
0441
1.ep
s
By padlocksLV848539SP
By Profalux keylocksProfalux 1 lock with 1 key + adaptation kit LV864928SP
2 locks 1 key + adaptation kit LV864929SP2 locks 2 different keys + adaptation kit LV864930SP
1 keylock Profalux (without adaptation kit):
identical key not identified combination LV833173SPidentical key identified 215470 combination LV833174SPidentical key identified 215471 combination LV833175SP
By Ronis keylocksRonis 1 lock with 1 key + adaptation kit LV864931SP
2 locks 1 key + adaptation kit LV864932SP2 locks 2 different keys + adaptation kit LV864933SP
1 keylock Ronis (without adaptation kit):
identical key not identified combination LV833189SPidentical key identified EL24135 combination LV833190SPidentical key identified EL24153 combination LV833191SPidentical key identified EL24315 combination LV833192SP
Adaptation kit (without keylock):
adaptation kit Profalux / Ronis LV864925SPadaptation kit Kirk LV864926SPadaptation kit Castell LV864927SP
Other circuit breaker accessoriesMechanical operation counter / 1 part
DB1
2561
7_2.
eps Operation counter CDM LV848535SP
Escutcheon and accessories / 1 part
DB4
2141
5.ep
s
DB4
0309
8_1.
eps
DB40
3099
_1.e
ps Fixed DrawoutEscutcheon LV848601SP LV848603SPTransparent cover (IP 54) LV848604SPEscutcheon blanking plate LV848605SP LV848605SP
Escutcheon Cover Blanking plateFront cover (3P / 4P) / 1 part
DB4
2143
7.ep
s
Front cover LV847939SP
Spring charging handle / 1 part
DB4
0441
3.ep
s Spring charging handle LV847940SP
Arc chute for Masterpact MTZ2/3 / 1 part
DB4
2143
8.ep
s
3P 4PType N1/NA/HF 3 x LV847935SP 4 x LV847935SPType H1/H2/HA (MTZ2 08 to MTZ2 40) 3 x LV847935SP 4 x LV847935SPType H1/H2/HA (MTZ3 40 to MTZ3 63) 6 x LV847936SP 8 x LV847936SPType H3 3 x LV847936SP 4 x LV847936SPType H10/HA10 3 x LV847869SP 4 x LV847869SPType L1 3 x LV847937SP 4 x LV847937SP
Appendix: Masterpact MTZ2/3 spare parts
D-7
D
Mechanical interlocking for source changeover
Mechanical interlocking for source changeoverInterlocking of 2 devices using connecting rods
DB4
2140
5.ep
s
Choose 1 set of 2 adaptation fixtures (1 for each device) + 1 set of rods1 set of 2 adaptation fixtures for Masterpact MTZ2 or MTZ3 fixed or drawout device LV847930SP1 set of 2 interlocking rods LV833210SPCan be used with 1 MTZ2/3 fixed + 1 MTZ2/3 drawout.Note: the installation manual is enclosed.
Interlocking of 2 devices using cables [1]
DB4
2140
6.ep
s
Choose 2 adaptation sets (1 for each device + 1 set of cables) 1 adaptation fixture for Masterpact MTZ2/3 fixed devices LV847926SP1 adaptation fixture for Masterpact MTZ2/3 drawout devices LV847926SP1 set of 2 cables LV833209SP[1] Can be used with any combination of MTZ1 or MTZ2/3, fixed or drawout devices.
Interlocking of 3 devices using cables
DB4
2140
7.ep
s
Choose 3 adaptation (inclusing 3 adaptation fixtures + cables) 3 sources, only 1 device closed, fixed or drawout devices LV848610SP2 sources + 1 coupling, fixed or drawout devices LV848609SP2 normal + 1 replacement source, fixed or drawout devices LV848608SP
Cable-type door interlock1 complete assembly for Masterpact MTZ2/3 fixed or drawout device LV848614SPNote: the installation manual is enclosed.
Appendix: Masterpact MTZ2/3 spare parts
D-8
D
Indication contacts
Indication contactsON/OFF indication contacts (OF) / 12 parts
DB4
0432
1_1.
eps 1 additional block of 4 contacts LV864922SP
Wiring For fixed circuit breaker LV847074SPFor drawout circuit breaker LV847849SP
"Fault trip" indication contact (SDE)/ 1 part
DB4
0432
3_1.
eps
Changeover contact (BDE) 6 A - 240 V LV847915SPLow-level LV847916SP
Wiring For fixed circuit breaker LV847074SPFor drawout circuit breaker LV847849SP
“Ready to close” contact (1 max.) / 1 part
DB4
0441
5.ep
s
PF1 changeover contact (5 A - 240 V) LV847080SP1 low-level changeover contact LV847081SPWiring For fixed circuit breaker LV847074SP
For drawout circuit breaker LV847849SP
“Connected, disconnected, test position” indication contact (carriage switches) / 1 part
DB4
0432
4_1.
eps Changeover contacts 6 A - 240 V LV833170SP
CE, CD, CT Low-level LV833171SP
Set of additional actuaters for carriage switches / 1 set1 set LV848560SP
Combined closed / connected contacts for use with 1 auxiliary contact / 1 part
DB40
4322
_1.ep
s 1 contact (5 A - 240 V) LV848477SPor 1 low-level contact LV848478SP
Electrical closing pushbutton / 1 part
DB40
4319
_1.e
ps BPFE1 pushbutton LV848534SP
Auxiliary terminals for chassis alone
DB4
0439
9.ep
s 3 wire terminal (1 part) LV847849SP6 wire terminal (1 part) LV847850SPJumpers (10 parts) LV847900SP
Appendix: Masterpact MTZ2/3 spare parts
D-9
D
Monitoring and control, Ethernet gateway
Communication option
DB4
2142
5.ep
s
DB4
2142
6.ep
s
ETH1
ETH2
DB4
2142
7.ep
s
DB4
2142
8.ep
s
EIFE Embedded Ethernet module full spare part kit for MTZ2/3-drawout LV851200SPEmbedded Ethernet spare part module MTZ1/2/3-drawout LV851001SP
IFE Ethernet interface LV breaker LV434010Ethernet interface for LV breakers and gateway LV434011
Microswitches for MTZ2/3 LV847905SPEIFE Acessories spare part kit for MTZ2/3 LV851220SPI/O application module LV434063
ULP port modules
24V0V
DB4
2306
2.ep
s
ULP port - for Masterpact MTZ2/3 - fixed LV850061SPULP port - for Masterpact MTZ2/3 - drawout LV850062SP
Accessories for Diagnostics & Communicating Releases
DB4
2143
4.ep
s Isolation module - for MX1/XF communicating coils LV850056SP
Monitoring and controlEthernet display module
DB4
1748
9.ep
s Switchboard front display module FDM128 LV434128
ULP wiring accessories [1]
DB1
2798
5.ep
s Breaker ULP cord L = 0.35 m LV434195Breaker ULP cord L = 1.3 m LV434196Breaker ULP cord L = 3 m LV434197
DB1
1144
3.ep
s 10 Modbus line terminators VW3A8306DRC [2]
DB1
1562
3.ep
s 5 RJ45 connectors female/female TRV00870
DB1
1144
4.ep
s 10 ULP line terminators TRV00880
DB4
2143
5.ep
s 10 RJ45/RJ45 male cord L = 0.3 m TRV0080310 RJ45/RJ45 male cord L = 0.6 m TRV008065 RJ45/RJ45 male cord L = 1 m TRV008105 RJ45/RJ45 male cord L = 2 m TRV008205 RJ45/RJ45 male cord L = 3 m TRV008301 RJ45/RJ45 male cord L = 5 m TRV00850
[1] For measurement display with Micrologic X.[2] See TeSys catalogue.
Appendix: Masterpact MTZ2/3 spare parts
APPENDIX:APPENDIX:
SPARE PARTSSPARE PARTS
E-1
Appendix: ECOFIT™ Plug&Play spare parts
Electrical auxiliaries ................................................................E-2
Mechanical auxiliaries ...........................................................E-3
Accessories ...............................................................................E-4
Appendix: ECOFIT™ Plug&Play spare parts
E
E-2
Electrical auxiliaries for chassisCarriage switches
DB4
0452
3.ep
s 4 connected position carriage switches CE 0685977c
DB4
2452
4.ep
s 2 disconnected position carriage switches CD 0685978c
Electrical auxiliariesAppendix: ECOFIT™ Plug&Play spare parts
E
E-3
Safety shutters VO
DB4
2452
7.ep
s
3P 4PUp to 2500 A 0685946c 0685947c3200 A 0685948c3200 A Left side neutral 0685949c
Right side neutral 0688532c
ChassisChassis frontplate 0685633cPosition indicator kit 9012783
Mechanical auxiliaries
Mechanical accessories for chassisMechanical interlock for drawout version
DB4
2452
5.ep
s Mechanical interlock for two circuit breakers VM2CT 0685975cMechanical interlock for two circuit breakers VM2CC 0685959c
DB4
2452
6.ep
s Mechanical interlock for three circuit breakers
VM31CT: 2 normal + 1 emergency 0684499cVM32CT: 2 inputs + 1 coupling 0684498cVM33CT: 3 inputs 0684497c
LocksInterlocking adaptation 0690462cInterlocking - H1/H2/HI/HF/N1/NI/LA/CC 0684991
SpringBolt spring 0685001Spring with a lockable bolt 0685002
Appendix: ECOFIT™ Plug&Play spare parts
E
E-4
Spares parts for chassisClusters (2P)
DB4
2452
8.ep
s 800 - 1600 A H1/H2/L1 - 1600 A N1 0685872c2000 - 2500 A N/H1/H2 0685874c2000 - 2500 A L1 - 3200A H1/H2 0685875c
Racking handle
DB4
2452
9.ep
s Racking handle 0685631c
Accessories
Horizontal terminations for drawout version (y 3200A)
DB4
2453
0.ep
s 800 - 1600 A H1/H2/L1 - 1600 A N1 (1P) 0685886c2000 - 2500 A N1/H1/H2 (1P) 0685887c3200 A H1/H2 - 2000 - 2500 A L1 3P 0685888c
4P 0685889c
Vertical terminations for drawout version (y 3200A)
DB4
2453
1.ep
s 800 - 1600 A H1/H2/L1 - 1600 A N1 (1P) 0685895c2000 - 2500 A N1/H1/H2 (1P) 0685896c3200 A H1/H2 - 2000 - 2500 A L1 Upper 3P 0685897c
4P 0685898cLower 3P 0685899c
4P 0685900c
Spares parts for Plug & Play assemblyInterlocking
DB4
2452
2.ai Interlocking kit, including cam and cut-out template EF548613
Appendix: ECOFIT™ Plug&Play spare parts
E
Schneider Electric
United KingdomStafford Park 5,TelfordShropshireTF3 3BLTel: 0870 608 8 608Fax: 0870 608 8 606www.schneider-electric.co.uk
SE9962 June 2017
©2017 - Schneider Electric. All rights reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies
This document has beenprinted on recycled paper
IrelandHead office, Block AMaynooth Business CampusMaynooth, Co. KildareW23 Y7X0Tel: 1 800 805 800Fax: (01) 601 2201www.schneider-electric.ie