ecolab tested for chemical resistance...email: [email protected] helukabel ® canada 3650 odyssey...

4
Ecolab Tested for Chemical Resistance Cables & Accessories Food & Beverage

Upload: others

Post on 28-Dec-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ecolab Tested for Chemical Resistance...Email: info@helukabel.mx HELUKABEL ® Canada 3650 Odyssey Dr., #4&5 Mississauga, ON L5M 0Y9 Phone: +1 289-444-5040 Fax: +1 289-444-5041 Email:

Ecolab Tested for Chemical Resistance

Cables & AccessoriesFood & Beverage

Page 2: Ecolab Tested for Chemical Resistance...Email: info@helukabel.mx HELUKABEL ® Canada 3650 Odyssey Dr., #4&5 Mississauga, ON L5M 0Y9 Phone: +1 289-444-5040 Fax: +1 289-444-5041 Email:

UL AWM Style 2517 Control Cable, PLTC

Available Sizes Gauge size / # of cond.: 28 — 16 AWG / 2 — 50

· Temperature range -25°C to +105°C (application dependent)

· Nominal voltage 300 V

*For twisted pairs: TRAYCONTROL® 300 TP, 300-C TP

· Insulation PVC/Nylon

· Outer Jacket Special PVC

· Approvals

Health and safety might only be the second most important

aspect of food products for consumers, after flavor, but food

quality is just as important. When it comes to ensuring food

safety and avoiding potential food epidemics, strict standards

are placed on plants and machinery. The VDMA, a leading

German engineering association, estimates washdown time

in the food industry to be between 20 and 30 percent of the

overall production time.

To avoid any germs or bacteria forming in this very sensitive

environment, equipment for the food and beverage industry

is subject to strict hygienic and antiseptic guidelines.

To stay ahead of future customer demand, HELUKABEL has

had its products tested and approved by Ecolab. With Ecolab

certification, HELUKABEL is demonstrating the capabilities of

its comprehensive product range for the washdown market.

Food should remain bacteria free

TRAYCONTROL® 600 & TRAYCONTROL® 600-C

UL 1277 & 2277 Power Cable, TC-ER, Oil Res I/II, Class 1 Div. 2, Type MTW FT-4

Available Sizes Gauge size / # of cond.: 20 AWG — 500 kcmil / 2 — 61

· Temperature range -40°C to +105°C (application dependent)

· Nominal voltage TC 600 V / WTTC1000 V

*For gray jacket: TRAYCONTROL® 500 & 500-C

· Insulation PVC/Nylon

· Outer Jacket Special PVC

· Approvals

TRAYCONTROL® X

TRAYCONTROL® 300 & TRAYCONTROL® 300-C

UL 1277 & 2277 Motor Power Cable

Available Sizes Gauge size / # of cond.: 18 — 2 AWG / 4

· Temperature range -40°C to +105°C (application dependent)

· Nominal voltage TC 600 V / WTTC & Flexible Motor Supply 1000

· Insulation XLPE

· Outer Jacket Special PVC

· Approvals

TOPFLEX® 600 VFD

*For control pairs: TOPFLEX® 650 VFD *For high flex: TOPSERV® 600 VFD, or with control pairs: TOPSERV® 650 VFD

HELUKABEL offers a range of products for use in sensitive sectors such as the food and beverage industry:

UL1277 & 2277 Power Cable

Available Sizes Gauge size / # of cond.: 20 AWG — 500 kcmil

· Temperature range -40°C to +105°C (application dependent)

· Nominal voltage TC 600 V / WTTC 1000 V 20 AWG 300 V

· Insulation XLPE

· Outer Jacket Special PVC

· Approvals

Page 3: Ecolab Tested for Chemical Resistance...Email: info@helukabel.mx HELUKABEL ® Canada 3650 Odyssey Dr., #4&5 Mississauga, ON L5M 0Y9 Phone: +1 289-444-5040 Fax: +1 289-444-5041 Email:

Tests were conducted at HELUKABEL’s testing facility in

accordance with Ecolab specifications. The test followed

a prescribed cleaning plan from pre-washing to foaming

to rinsing. The material resistance test it conducted was

configured based on the material used in the cable’s

outer jacket

The test was performed with various cleaning and

disinfecting agents for the food and beverage industry:

· P3-topax 200 - Alkaline, chlorine-free foam cleaner

· P3-topax 500 - Acid foam cleaner

· P3-topax 990 - Neutral, non-oxidizing disinfecting

agent

· P3-topax 66 - Alkaline cleaner and disinfectant with

active chlorine

· P3-topactive Okto - Acidic foam disinfectant with a

peroxyacid basis

· Distilled water as a zero value

A cable with a PVC outer jacket was submerged in each

test medium for 28 days at constant room temperature.

A tensile elongation test was then conducted to detect

any swelling, cracks, color changes, or changes to the

surface characteristics or dimensions.

The tested PVC jacket material successfully withstood

the procedure.

PVC blend withstands Ecolab testing

*For control pairs: TOPFLEX® 650 VFD *For high flex: TOPSERV® 600 VFD, or with control pairs: TOPSERV® 650 VFD

Page 4: Ecolab Tested for Chemical Resistance...Email: info@helukabel.mx HELUKABEL ® Canada 3650 Odyssey Dr., #4&5 Mississauga, ON L5M 0Y9 Phone: +1 289-444-5040 Fax: +1 289-444-5041 Email:

Glands, Conduit & Hose Fittings

Andaconda Sealtite® FG-Clean IP67 protection class rated Operating Temperature: -20°C — +60°C FDA CFR 21 & NSF 51 compliant

LG-FG- Clean IP67 protection class rated Operating Temperature: -45°C — +105°C FDA CFR 21 & NSF 51 compliant

HELUTOP® HT-Clean Stainless steel IP68 & IP69K protection class ratedFDA 21 CFR 177.2600 compliant

New additions to the hygienic accessories range are the

HELUTOP® HT-Clean stainless steel cable glands, the Anaconda

Sealtite® FG-Clean protective conduit, and LT-FG-Clean stainless

steel hose fittings. All three have smooth surfaces that prevent

dangerous organisms from taking hold and enable easy, fast and

inexpensive cleaning. Sterilization can also be done using high-

pressure cleaning equipment. Moreover, they are resistant to

chemical cleaning agents, prevent the formation of contaminates,

and do not allow foreign bodies to penetrate the casing.

CONTACTS

helukabel.com

HELUKABEL® MexicoBusiness Park Conín,Carretera Federal 57 México -Querétaro, Lateral NorteKm 201 + 100, Mod. 67 & 69C.P. 76240 El Marqués, QuerétaroPhone: +52 442-209-6400Email: [email protected]

HELUKABEL® Canada3650 Odyssey Dr., #4&5Mississauga, ON L5M 0Y9Phone: +1 289-444-5040Fax: +1 289-444-5041Email: [email protected]

HELUKABEL® USA1201 Wesemann Dr. West Dundee, IL 60118Toll Free: +1 855-HELUUSAPhone: +1 847-930-5118Fax: +1 847-622-8766Email: [email protected]

helukabel.mx

helukabel.ca

Want to download our catalogs?Scan the QR code to download instantly!