effect of intermediate stiffeners on the behaviors of...

16
Research Article Effect of Intermediate Stiffeners on the Behaviors of Partially Concrete Encased Steel Beams Cheng-Cheng Chen 1,2 and Teguh Sudibyo 1,3 1 Department of Civil and Construction Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan 2 Taiwan Building Technology Center, National Taiwan University of Science and Technology, Taipei 10607, Taiwan 3 Department of Civil Engineering, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia Correspondence should be addressed to Teguh Sudibyo; [email protected] Received 16 March 2018; Revised 20 June 2018; Accepted 29 October 2018; Published 25 November 2018 Academic Editor: Melina Bosco Copyright©2018Cheng-ChengChenandTeguhSudibyo.isisanopenaccessarticledistributedundertheCreativeCommons AttributionLicense,whichpermitsunrestricteduse,distribution,andreproductioninanymedium,providedtheoriginalworkis properly cited. Partially concrete encased steel (PE) beams are composite steel beams and concrete elements that present several advantages, such as higher fire resistant, higher flexural capacity, and higher lateral torsional buckling resistant compared to bare steel beams. is paper reports an experimental study of eight PE beams under cyclic loading. e effectiveness of intermediate stiffeners, such as midspan stiffener and plastic hinge zone stiffener, in enhancing composite action and ductility of the PE beams was studied. e ductility performance of PE beams using strengthened beam-to-column connection and weakened beam-to-column connection was also investigated.etestresultsshowthattheplastichingezonestiffenerperformedwellandhasthepotentialtoreplaceshearconnectors. Strengthenedandweakenedbeam-to-columnconnectionscanbeimplementedinPEbeamstoenhancetheductilityofthePEbeams; withthedetailsofbothstrengthenedandweakenedbeam-to-columnconnectionsdeterminedbybaresteelshapeinsteadofthewhole section. In addition, the suggestions to prevent premature failure of weakened beam-to-column connection were provide. 1. Introduction Fire-proofing material is usually used to provide fire re- sistancetothesteelmembersinhigh-risebuildings.efire- proofing material may cause pollution to the environment; therefore, extra construction material is often needed to coverthefire-proofingmaterial.Fullyconcreteencasedsteel beam or steel-reinforced concrete (SRC) beam, as shown in Figure 1(a), uses concrete to provide fire resistance to the steel in the beam; therefore, the pollution problem of fire proofing material can be avoided. However, the concrete brings extra vertical and seismic loads to the structure and theconstructioniscomparativelymoredifficultandrequires intensive labor. e partially concrete encased steel beam shown in Figure 1(b) uses concrete in cooperation with fire-proofing coating to provide fire resistance to the steel beams. e concreteencasementonpartiallyconcreteencasedbeamcan effectively prevent the temperature of steel from rising sharply [2–4]. Compared to the SRC beams, this type of partially concrete encased steel beam, defined as PE beam hereafter, reduces the amount of concrete used, which re- duces the vertical and seismic load on the structure. In addition, PE beams reduce the requirement for formwork, shoring, and steel cage fabrication. is reduces construc- tion difficulties and cost. Furthermore, the presence of concrete infill between the steel flanges also contributes to PEbeamtohavehigherbendingresistance[5–8]andhigher lateral-torsional buckling (LTB) resistance than bare steel beam[1,9].eseadvantageshaveledtowideapplicationof PE beam to be used in modern construction. e PE beam shown in Figure 1(b) is the type of beam investigated here. Several studies have been conducted to examine the composite action on PE beams. Kindmann et al. [5] in- vestigated the composite behavior of PE beams under monotonicloading.Itwasfoundthatshearconnectorswere Hindawi Advances in Civil Engineering Volume 2018, Article ID 8672357, 15 pages https://doi.org/10.1155/2018/8672357

Upload: others

Post on 05-Feb-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

Research ArticleEffect of Intermediate Stiffeners on the Behaviors of PartiallyConcrete Encased Steel Beams

Cheng-Cheng Chen1,2 and Teguh Sudibyo 1,3

1Department of Civil and Construction Engineering, National Taiwan University of Science and Technology, Taipei 10607,Taiwan2Taiwan Building Technology Center, National Taiwan University of Science and Technology, Taipei 10607, Taiwan3Department of Civil Engineering, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia

Correspondence should be addressed to Teguh Sudibyo; [email protected]

Received 16 March 2018; Revised 20 June 2018; Accepted 29 October 2018; Published 25 November 2018

Academic Editor: Melina Bosco

Copyright © 2018 Cheng-Cheng Chen and Teguh Sudibyo.,is is an open access article distributed under the Creative CommonsAttribution License, which permits unrestricted use, distribution, and reproduction in anymedium, provided the original work isproperly cited.

Partially concrete encased steel (PE) beams are composite steel beams and concrete elements that present several advantages, such ashigher fire resistant, higher flexural capacity, and higher lateral torsional buckling resistant compared to bare steel beams. ,is paperreports an experimental study of eight PE beams under cyclic loading. ,e effectiveness of intermediate stiffeners, such as midspanstiffener and plastic hinge zone stiffener, in enhancing composite action and ductility of the PE beams was studied. ,e ductilityperformance of PE beams using strengthened beam-to-column connection and weakened beam-to-column connection was alsoinvestigated.,e test results show that the plastic hinge zone stiffener performed well and has the potential to replace shear connectors.Strengthened and weakened beam-to-column connections can be implemented in PE beams to enhance the ductility of the PE beams;with the details of both strengthened and weakened beam-to-column connections determined by bare steel shape instead of the wholesection. In addition, the suggestions to prevent premature failure of weakened beam-to-column connection were provide.

1. Introduction

Fire-proofing material is usually used to provide fire re-sistance to the steel members in high-rise buildings.,e fire-proofing material may cause pollution to the environment;therefore, extra construction material is often needed tocover the fire-proofing material. Fully concrete encased steelbeam or steel-reinforced concrete (SRC) beam, as shown inFigure 1(a), uses concrete to provide fire resistance to thesteel in the beam; therefore, the pollution problem of fireproofing material can be avoided. However, the concretebrings extra vertical and seismic loads to the structure andthe construction is comparatively more difficult and requiresintensive labor.

,e partially concrete encased steel beam shown inFigure 1(b) uses concrete in cooperation with fire-proofingcoating to provide fire resistance to the steel beams. ,econcrete encasement on partially concrete encased beam can

effectively prevent the temperature of steel from risingsharply [2–4]. Compared to the SRC beams, this type ofpartially concrete encased steel beam, defined as PE beamhereafter, reduces the amount of concrete used, which re-duces the vertical and seismic load on the structure. Inaddition, PE beams reduce the requirement for formwork,shoring, and steel cage fabrication. ,is reduces construc-tion difficulties and cost. Furthermore, the presence ofconcrete infill between the steel flanges also contributes toPE beam to have higher bending resistance [5–8] and higherlateral-torsional buckling (LTB) resistance than bare steelbeam [1, 9].,ese advantages have led to wide application ofPE beam to be used in modern construction. ,e PE beamshown in Figure 1(b) is the type of beam investigated here.

Several studies have been conducted to examine thecomposite action on PE beams. Kindmann et al. [5] in-vestigated the composite behavior of PE beams undermonotonic loading. It was found that shear connectors were

HindawiAdvances in Civil EngineeringVolume 2018, Article ID 8672357, 15 pageshttps://doi.org/10.1155/2018/8672357

Page 2: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

not necessary to develop composite action of the beams.However, the beams tested used tension reinforcement,which reduced the requirement for shear connectors. Nardinand Debs [6] examined the composite action of PE beams bytesting simply supported rectangular beams with monotonicloading. �e beam tested had enlarged bottom �ange, whichleads to higher requirement for shear connectors. Test resultssuggested that shear connectors are required for the beamsto develop a composite action, and shear connectors in-stalled on the bottom �ange developed higher compositeaction than those installed on the web did. In addition, theslip between concrete and steel at the end of the test beamswent beyond 2.0mm at the time when the �exural strengthwas developed. Hegger and Goralski [7] evaluated the�exural capacity of PE beams which were integrated withconcrete slab under both sagging and hogging moment. �etest results showed that, when the beam under saggingmoment, the �exural capacity of the beam with and withoutshear connection nearly had no di�erence. �e load-deformation diagram of beam with and without shearconnection could be recognized without any di�erences,with the load di�erences about 1%. �e measured slip at theend of the concrete encasement was always less than 0.2mm.�e shear force was transferred by friction forces betweenthe �anges of the steel pro�le and the concrete encasement.While under hogging moment, the beam without su�cientshear connection showed lower �exural strength. Chen et al.[8] conducted monotonic and cyclic tests on PE beams withspan length of 0.75m and 1.5m (shear span ratio of 1.5 and3, respectively). �e plastic moment capacity is exceeded forall the test specimens and also showed good ductility underboth monotonic and cyclic loading.

At present, research on PE beam used shear connectionto develop the composite action between the steel shape andthe concrete encasement which was tested by simply sup-porting with monotonic loading [5–7]. However, when a PEbeam forms part of a moment resisting frame, as shown inFigure 2, the columns may provide constraint to the beam atthe beam ends and suppress the slip between concreteand steel shape surfaces, as schematically explained inFigure 2(b). �is column constraint should have positivee�ect on the development of beam composite action. How-ever, when the distance between beam ends, or columns, is

too far, the e�ect of the column constraint may be reduced. Inthis case, extra sti�eners installed between the length of PEbeam, referred as intermediate sti�eners, may provide extraconstraint and further enhance the composite action. For thebeam shown in Figure 2 subjected to earthquake type loading,a sti�ener at the midspan, as shown in Figure 2(c), wherebending moment changes direction, may be helpful. In ad-dition, a sti�ener installed near the plastic hinge zone, wherethe requirement for composite action is the highest in thebeam span, should be advantageous to PE beam to develop its�exural strength.

In steel structures, it is common practice to move theplastic hinge away from the column surface to preventpremature fractures of the welds connecting the beam �angeand the column �ange. Strengthened beam-to-columnconnections (SBC) and weakened steel beam-to-columnconnections (WBC) have been suggested to solve thisproblem [10–14]. A PE beam has the same concerns as a steelbeam has. And, it is of interest to the authors how PE beamsperform when SBC or WBC is used.

In this study, a total of 8 PE beam specimens werefabricated and tested under cyclic loading. �e e�ectivenessof column constraint and intermediate sti�eners, such asmidspan sti�ener and plastic hinge zone sti�ener, was in-vestigated. In addition, the suitability of SBC andWBC to PEbeams is assessed.

2. Experimental Program

2.1. Test Specimens. �e designations of the 8 specimenstested are shown in Table 1. Each test specimen wasmountedto a pair of columns, as shown in Figure 3. �e test setupcon�guration used in this research is similar with the testscheme conducted by Sudibyo and Chen [15]. �e columnsand the end-plate connections possessed very high sti�nessand strength so that their deformation can be neglected. Allthe specimens were symmetrical with respect to their centerlines and had a clear span length of 1200mm. �e bottomend of each column was connected to a rigid base through ahinge.

Figure 4(a) shows the geometry and dimensions of thecross section used. �e cross-sectional steel shape used,which was H 150 × 75 × 5 × 7, had a �ange width-to-

Longitudinalsteel bar

Transversesteel barConcrete

H shape

Concrete slab

(a)

ConcreteH shape

Concrete slab

Fire-protection coating

(b)

Figure 1: Concrete encased steel beam; adapted from “Behavior of Partially Concrete Encased Steel Beams under Cyclic Loading” [1]. (a)Fully concrete encased steel beam/SRC. (b) Partially concrete encased steel beam.

2 Advances in Civil Engineering

Page 3: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

thickness ratio of 5.4.�e ends of cross-sectional steel shapeswere connected to the end plates with complete penetrationwelds. ASTM A36 steel with a nominal yield stress of250MPa and concrete with a speci�ed compressive strengthof 30MPa were used to design the specimens.

�ere were 4 specimens in the PW series. In this group, atype of weakened beam-to-column connections proposed byChen et al. [11], as shown in Figure 5(a), were used. �e-oretically, the geometry of the �ange tapering should bedetermined according to the �exural strength of the wholePE section (i.e., steel shape plus concrete). However, itbecomes tedious. Instead, for the purpose of simplicity, thegeometry of the �ange tapering, as shown in Figure 5(a), wasdetermined based on steel shape alone. Figure 6(a) shows themoment capacity distribution along the beam, where Mpd(24.5 kN·m) is the design plastic moment (also the nominaldesign �exural strength) of H 150 × 75 × 5 × 7 calculatedwith nominal yield stress of the steel. �e plastic moment iscalculated as speci�ed in Table 4.1 of ANZI/AISC 360-16[16]. Projecting the moment capacity of Section C to thebeam end resulted in a beam end moment of 0.92 Mpd.

When determining the geometry of �ange tapering, thebeam end moment was controlled in between 0.90 and 0.95Mpd and the distance between the critical section (Section C)and the end of the welding access hole was kept 25mm.

After the determination of the geometry of the �angetapering, the distribution of nominal design moment ca-pacity Mnd, based on whole section, along the beam wascalculated and is shown in Figure 6(b).�e nominal momentcapacity is the moment capacity of the whole composite PEsection, with complete composite action, based on the plasticstress distribution method as speci�ed in Section I1.2a ofANZI/AISC 360-16 [16] and schematically explained inFigure 4(b). �e factor β1 used in the calculation is referredto ACI [17].�eMnd (26.9 kN·m) is calculated with nominalyield stress of the steel. �e ideal condition for weakenedbeam-to-column connection is that the sections in the ta-pered �ange region reach their design moment capacitysimultaneously [11]. It can be found from Figure 6(b) thatthe sections between C and D reach their moment capacityalmost at the same time. �is shows that determining thegeometry of the �ange tapering based on steel shape alone

Table 1: Details of test specimens.

Series Specimen Steel beam cross section Connection typea Composite action deviceb

PS

PS-NB RH 150 × 75 × 5 × 7 SBC —PS-SC RH 150 × 75 × 5 × 7 SBC Shear connectorPS-MS RH 150 × 75 × 5 × 7 SBC Midspan sti�enerPS-HS RH 150 × 75 × 5 × 7 SBC Plastic hinge zone sti�ener

PW

PW-NB RH 150 × 75 × 5 × 7 WBC —PW-SC RH 150 × 75 × 5 × 7 WBC Shear connectorPW-MS RH 150 × 75 × 5 × 7 WBC Midspan sti�enerPW-HS RH 150 × 75 × 5 × 7 WBC Plastic hinge zone sti�ener

aDetails of beam-to-column connection are shown in Figures 5–7. bDetails of composite action device are shown in Figure 8.

M–

M+

Column

Beam

(a)

Column constraint

Column

Steel shape

Concrete

PE beam

(b)

Plastic hinge zone stiffener

Midspan stiffener

Column

Beam (only steelsection shown)

Plastic hinge zone

(c)

Figure 2: PE Beam in a moment resisting frame. (a) Moment distribution of the beam under earthquake type loading. (b) Columnconstraint at beam end. (c) Plastic hinge zone sti�ener and midspan sti�ener.

Advances in Civil Engineering 3

Page 4: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

should be quite satisfactory. �e critical section located atSection C. Projecting the design moment capacity of SectionC to the beam end resulted in a usable design beam endmoment of 0.93Mnd.

�ere were 4 specimens in the PS series. In this group,strengthened beam-to-column connections, as shown inFigure 5(b), were used. Similar to PW specimens, the coverplates of PS specimens were designed based on steel shapealone for simplicity. �e length of the cover plates wasdetermined in such a way that the critical section located at adistance of 25mm away from the end of the welding accesshole. In order to prevent failure at beam end, the momentcapacity of the combination of �anges and cover plates waskept at least 1.2 time of Mpd. Figure 7(a) shows the designplastic moment distribution along the beam. Figure 7(b)

shows the design nominal moment capacity, based on wholesection, along the beam.�e critical section located at C andthe usable beam end moment was 1.09Mnd. �e H shapedetail used in this research is the same with the steel con-�guration conducted by Sudibyo and Chen [15]; therefore,the moment capacity distribution of the steel shape, Fig-ures 6(a) and 7(a), are the same as those in [15].

�e specimens with “SC” in their designation wereequipped with shear connectors, as shown in Figure 8(a). �especimens with “MS” in their designations had a midspansti�ener installed, as shown in Figure 8(b). �e specimenswith “HS” in their designations had one plastic hinge zonesti�ener installed at each end of the beam. �e plastic hingezone sti�eners were installed at the position 175mm, which is1.2 times the beam depth, from the end plate, as shown in

RH 150 × 75 × 5 × 7

Concrete

0.85 f ′c

fy

fy

Concrete(a) (b)

Steel shape

N.A.

β1 . c′c′

β1 is the β1 definedby ACI [17]

Figure 4: (a) Cross section. (b) Plastic stress distribution method, AISC [16].

Lb = 1200

Hinge

L c=

1200

End plate connection

Test specimen

Load

16

H300 × 300 × 10 × 15

Section A-A A A

Stiffener

Stiffener

Lh = 1600

Figure 3:�e test scheme for beam specimens (unit: mm); adapted from “�e E�ect of Intermediate Sti�eners on Steel Reinforced ConcreteBeam Behaviors” [15].

4 Advances in Civil Engineering

Page 5: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

Figures 5 and 8(b). Specimens with “NB” in their designationsused neither shear connector nor sti�ener.

�e mechanical properties of the H steel shape are listedin Table 2. All the specimens used ready-mixed concrete

without coarse aggregate. �e specimens were cast in ahorizontal position in two stages: the concrete on one side ofthe steel beamwas cast �rst, and the concrete on the other sideof the steel beam was cast a week later. �e compressive

(B) Top view

15

75

25

150

35

50

7560 49250

130

175

Typ. 45°

150

27

(A) Elevation view

150Typ. on

web

Plate 400 × 250 × 50

175

25

Stiffener (for PW-HS) t = 9mm

Stiffener (for PW-HS) t = 9mm

Critical section

300400

(a)

(A) Elevation view (B) Top view

50

156

Typ.

Cover plate t = 6mm

250

130

7550

Plate 400 × 250 × 50

50

27Typ.

45°

Cover plate t = 6mm

150

175

Typ. onweb

175

25

Stiffener (for PS-HS) t = 9mm

Stiffener (for PS-HS) t = 9mm

Critical section

300400

(b)

Figure 5: Detail of beam-to-column connection for the H shape (unit: mm). (a) WBC connection. (b) SBC connection.

Columnsurface

Centerline

50125

L = 600mm

0.92

Mpd

AA′

B E

CD

F

Assumed inflectionpoint

0.85

Mpd

0.73

Mpd

Mpd

Critical section

M

Moment capacityof steel shape

(a)

Columnsurface

Centerline

50125

L = 600mm

0.93

Mnd

AA′

B E

CD

F

Assumed inflectionpoint

0.85

Mnd

0.74

Mnd

Mnd

Critical section

M

(b)

Figure 6: Design moment capacity distribution of the beam with WBC connection. (a) Steel shape; adapted from [15]. (b) Whole section.

Advances in Civil Engineering 5

Page 6: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

strength on each side of the steel beamwas 38.1 and 38.8MPa,respectively. �e average value (38.4MPa) was taken as theconcrete compressive strength for the specimens.

2.2. Test Setup and Loading Procedure. �e test setup isshown in Figure 9. A servo-controlled hydraulic actuatorwith a capacity of 500 kN was connected to the right column.�e actuator was equipped with a built-in load cell and

built-in linear variable di�erential transducers (LVDT) tomeasure, respectively, the applied force P and the lateraldisplacement at the load point. �e lateral displacement atthe load point is de�ned as displacement of the right column.�e displacement of the left column was measured by anLVDTat the beam center.�e average of displacement of theleft and right column is de�ned as the lateral displacementΔ.Rotation gauges R1 and R2 were installed on the end platesof the beam, and rotation gauges R3 and R4 were installed

Columnsurface

Centerline

Mpd

50

A

B1.

48M

pd1.

14M

pdCA′

1.09

Mpd

Critical sectionL = 600mm

Assumed inflectionpoint

M

Moment capacityof steel shape

(a)

Columnsurface

Centerline

Mnd

50

A

B

CA′

1.09

Mnd

Critical sectionL = 600mm

Assumed inflectionpoint

M

1.43

Mnd

1.13

Mnd

(b)

Figure 7: Design moment capacity distribution of the beam with SBC connection. (a) Steel shape; adapted from [15]. (b) Whole section.

3@170

H150 × 75 × 5 × 7

Shear connector 30 × 30 × 3, l = 25

600

Centerline

3 Typ.

(a)

60050

Centerline

End plate

Plastic hinge zone stiffener, t = 9mm(for PS-HS and PW-HS)

Midspan stiffener, t = 9mm(for PS-MS and PW-MS)

Steel shape175

6 6

(b)

Figure 8: Concrete constraint scheme. (a) Elevation view specimens with shear connectors (PS-SC and PW-SC). (b) Elevation view (PS-NB,PS-HS, PS-MS, PW-NB, PW-HS, and PW-MS).

Table 2: Mechanical properties of H 150 × 75 × 5 × 7 and concrete.

Tensile strength of H 150 × 75 × 5 × 7 (MPa) Concrete compressive strength (MPa)

Nominal yield stressTensile test

Nominal strengthfc′

Component fy fu Side 1 Side 2

250

Flange271.9 377.9

30

39.0 37.4273.7 377.1 40.1 38.8271.9 371 38.4 40

Average 272.5 375.3 40.9 40.242.4 39.3

Web295.7 390.2 32.8 39.6290.5 392.9 37.1 38.5289.6 387.6 34.7 36

Average 291.9 390.2 Average 38.1 38.838.4

6 Advances in Civil Engineering

Page 7: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

175mm from each beam end. ,e beam segments betweenR1 and R3 and between R2 and R4 are defined as plastichinge zones. ,e axial link was used to reduce axial force inthe specimens.

A quasi-static load was applied under displacementcontrol according to the lateral displacement history shownin Figure 10. Δy is defined as the measured lateral dis-placement of the frame when the moment at beam ends, asindicated in Figure 11, reached nominal moment capacityMna (29.56 kN·m) of the test beams. Mna is the momentcapacity of the whole composite section, calculated based onthe actual material strength, complete composite action,plastic stress distribution method (Section I1. 2a ANZI/AISC 360-16) [16] as shown in Figure 4(b). A Δy of7.5mm was obtained and used for all the specimens. It isnoted that the moment distribution presented in Figure 11 isbased on the assumption of antisymmetrical moment dis-tribution of the beam. Since the test scheme (Figure 3) andthe H shape configuration (Figure 5) of the specimens usedin this research are the same as those used by Sudibyo andChen [15], the moment distribution of the beam (Figure 11)is the same as that used by Sudibyo and Chen [15]. ,e loadtest ended when the strength of the specimen deterioratedmore than 20%.

3. Experimental Results and Discussion

3.1.GeneralBehavior. ,e P versusΔ hysteretic loops for thespecimens are shown in Figure 12, and the test results aresummarized in Table 3. ,e drift angle α of the frame isdefined as the corresponding Δ divided by Lc.,emaximumloads in the positive and negative directions are designated,respectively, as P+

peak and P−peak. ,e maximum load for thetested specimen Pexp is defined as the average of P+

peak andP−peak. SBC and WBC are intended to prevent failure of thewelds connecting the beam and the column, and the failure

of the beam was designed to occur at the critical section ofthe beam, as shown in Figures 5–7. ,erefore, the followinganalysis is performed based on beam’s moment capacity inthe critical section.

According to the moment distribution shown inFigure 11, the moment at the critical section correspondingto Pexp, designated as Mexp, can be calculated as follows:

Mexp �12PexpLc

0.5 · Lcs

0.5Ls� 0.344PexpLc. (1)

It is worth noting that Mexp is an underestimate since thestrength of the beam at both ends was, very likely, notdeveloped at the same time.,e nominal moment capacitiesof the critical section (Mna)c for PS specimens and PWspecimens were 29.6 kN·m and 25.1 kN·m, respectively, aslisted in Table 4.,e strength ratio c is defined as the ratio ofMexp and (Mna)c. ,e plastic moment of the steel shape in

Reac

tion

wal

l

Actuator

Pinnedconnection

Pinnedconnection

R3 R4

Beam specimen

Strong floor

Position of lateral support

(+)(–)P, ∆

Position oflateral support

LVDT

R1 R2

175 175

Pinnedconnection

Pinned connectionAxial link

Figure 9: Test setup.

0 4 8 12 16 20No. of cycles

–8

–4

0

4

8

±0.25∆y

±0.5∆y

±0.75∆y

±∆y

±2∆y

±3∆y

±4∆y

±5∆y

±6∆y

±8∆y

Load

ing

disp

lace

men

t (∆ y

)

Figure 10: Loading history.

Advances in Civil Engineering 7

Page 8: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

the critical section, calculated using actual yield stress ofsteel, (Mp)c for PS specimens and PW specimens were26.7 kN·m and 22.6 kN·m, respectively, as listed in Table 4.And, the strength ratio c′ is defined as the ratio ofMexp and (Mp)c. ,e strength ratios c and c′ of all thespecimens are listed in Table 3. It is noted that the ratio(Mna)c/(Mp)c was 1.11 for both PS and PW specimens. ,isindicates that the existence of the concrete raises the mo-ment capacity of the steel beam by about 11%.

,e rotation of the left and right plastic hinge zones ofthe beam are designated as θL and θR, respectively. θL wascalculated by subtracting R3 readings from R1 readings, andθR was calculated by subtracting R4 readings from R2readings. Figure 13 shows the lateral load versus plastichinge rotation hysteresis loops for specimen PS-HS. ,e P

vs. θ skeleton curves based on first cycle of each drift ratioexcursion for PS and PW series are shown in Figures 14and 15, respectively. ,e yield rotation θy and ultimaterotation θu were determined based on P vs. θ skeleton curveof each specimen. Figure 16 shows positive P versus θLskeleton curve based on the first cycle of each drift angleexcursion. ,e ultimate rotation θ+

uL is defined as the ro-tation corresponding to 85% of P+

peak in the descendingportion. ,e elastic rotation θ+

yL, as indicated in Figure 16, isthe estimated elastic rotation corresponding to P+

peak. ,eplastic hinge rotation capacity θ+

pL was the difference be-tween θ+

uL and θ+yL. ,rough the procedure aforementioned,

θ+pL, θ−pL, θ

+pR, and θ−pR for each specimen were determined.

,e plastic hinge rotation capacity, θp, of each specimen isdefined as the average of θ+

pL, θ−pL, θ

+pR, and θ−pR.

3.2. Behaviors of PS Series. ,e failure procedure for all PSspecimens was similar. Concrete crushing and steel flangebuckling, as shown in Figure 17(a), was observed when theapplied load reached P+

peak and P−peak. After that, cracks atthe end of the cover plate started to develop and eventu-ally caused the fracture of the steel flange, as shown in

Figure 17(b). ,e hysteresis loops of the specimens are quitestable up to one or two cycles after local buckling of steelflange occurs.

Figures 18(a)–18(d) show the condition and the crackpattern of PS specimens after the first 5% cycle. ,e damageon the right end of the specimen is more severe than that onthe left end, which indicates that the strength of the beam atthe two ends did not develop at the same time. And, Pexp andMexp underestimate the real strength of the beams. Con-sequently, specimen PS-SC, which is considered possessingcomplete composite action, has a strength ratio c (0.99)slightly less than 1.0.

–80–60–40–20

020406080

100–8 –6 –4 –2 0 2 4 6 8

Drift angle (%) Drift angle (%)–6 –4 –2 0 2 4 6 8

–80–60–40–20

020406080

100

–80–60–40–20

020406080

100

–100 –8

0–6

0–4

0–2

0 0 20 40 60 80 100

Displacement (mm)

–100–80–60–40–20

020406080

100

–80

–60

–40

–20 0 20 40 60 80 100

Displacement (mm)

(a)

(f)

(g)

(h)(d)

(b)

(e)

(c)

Peak loadLocal buckling of steel flangeFracture of steel flange

Load

P (k

N)

Load

P (k

N)

Load

P (k

N)

Load

P (k

N)

Figure 12: Load versus displacement hysteresis loops. (a) PS-NB. (b)PS-SC. (c) PS-MS. (d) PS-HS. (e) PW-NB. (f) PW-SC. (g) PW-MS. (h)PW-HS.

Critical sectionBeam end

L c =

120

0mm

Centreof span

Centre of column

Centre of column

Load

Lcs = 1100mm

Lb = 1200mm

Ls = 1600mm

Figure 11: Moment distribution of the frame; adapted from “,eEffect of Intermediate Stiffeners on Steel Reinforced ConcreteBeam Behaviors” [15].

8 Advances in Civil Engineering

Page 9: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

3.3.Behaviors of PWSeries. Due to the tapering of the flange,concrete occupied the space where flange was tapered, in-dicated as “flange concrete” in Figure 19. When the flangeconcrete was subjected to compressive force, it was pushedsideward and caused concrete damage to occur earlier thanthat of PS specimens, as shown in Figure 20. Since the flangesof PW specimen were tapered and a smaller width-to-thickness ratio is then resulted, flange local buckling oc-curred somewhat later than PS specimens did, as indicatedin Figure 12.

,e crack patterns of PW specimens, as shown in Fig-ures 18(e)–18(h), also show that the concrete damage on theright end of the specimen is more severe than that on the leftend. PW specimens experienced more severe concretedamage than the corresponding PS specimens.

Cracking of the steel flange was observed after peakloads were reached. Cracking, as indicated in Figure 21(a),

Table 3: Test result of test specimens.

Series Specimen P+peak (kN) α+

peak (%) P−peak (kN) α−peak (%) Pexp (kN) Mexp (kN.m) c c′ θp (%)

PS

PS-NB 68.0 3.75 −66.3 −3.13 67.2 27.70 0.94 1.04 5.44PS-SC 72.3 3.75 −69.8 −3.75 71.1 29.31 0.99 1.10 5.21PS-MS 69.5 3.75 −68.2 −3.75 68.8 28.39 0.96 1.06 5.67PS-HS 71.4 3.75 −68.8 −3.13 70.1 28.91 0.98 1.08 6.11Average 69.3 0.97 5.61

PW

PW-NB 54.8 3.75 −54.1 −3.13 54.5 22.46 0.89 0.99 4.52PW-SC 56.8 3.75 −55.5 −3.13 56.1 23.15 0.92 1.02 4.75PW-MS 56.8 3.75 −55.9 −3.75 56.3 23.23 0.93 1.03 4.69PW-HS 55.6 3.13 −54.3 −3.13 55.0 22.67 0.90 1.00 4.74Average 55.5 0.91 4.67

Table 4: Moment capacity of the section.

Plastic moment of steel shape (kN·m) Nominal moment capacity (kN·m)

Mpd(a) (Mp)c

(b)

Mnd(a) Mna

(b) (Mna)c(b)

PS PW PS PW24.5 26.7 22.6 26.9 29.6 29.6 25.1(a)Calculated with the material’s nominal strength. (b)Calculated with the material’s actual strength (test value).

–100–80–60–40–20

020406080

100 (a)

–0.08 –0.06 –0.04 –0.02 0 0.02 0.04 0.06 0.08Rotation (rad)

–100–80–60–40–20

020406080

100P+

P−

P−

(b)

P+

Load

(kN

)Lo

ad (k

N)

Figure 13: Load vs plastic hinge rotation of specimen PS-HS. (a)Right plastic hinge rotation (θR). (b) Left plastic hinge rotation (θL).

–80

–60

–40

–20

0

20

40

60

80

Load

(kN

)Lo

ad (k

N)

(a)

–0.08 –0.06 –0.04 –0.02 0 0.02 0.04 0.06 0.08Rotation (rad)

–80

–60

–40

–20

0

20

40

60

PS-NBPS-SC

PS-MSPS-HS

(b)

Figure 14: Skeleton curve of plastic hinge rotation for PS series. (a)Right plastic hinge rotation (θR). (b) Left plastic hinge rotation (θL).

Advances in Civil Engineering 9

Page 10: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

started from the center of the flange just above the endof the welding access hole. ,e crack then extendedtoward the tapered region of the flange. Figure 21(b)shows the flange fracture of PW-NB specimen. ,e pre-mature flange fracture and the extra concrete damage nearthe flange tapering region reduced the experimentalstrength of the specimens. As a result, the strength ratio ofPW-SC (0.92) is even lower than that of PS-SC (0.99) byabout 7%.

,e premature flange fracture should be deferred, andhigher flexural strength and ductility should be developed iflarger access hole-taper start clearance is provided [11].

3.4. Effectiveness of Intermediate Stiffeners. Since prematurefailure of the PW specimens was observed, it is more reliableto compare the effectiveness of composite action based ontest results from PS specimens. Take PS-SC as a reference,the Pexp/(Pexp)SC ratio and θp/(θp)SC ratio of PS-NB, PS-MS,and PS-HS are calculated and listed in Table 5, where(Pexp)SC and (θp)SC are the Pexp and θp of PS-SC specimen.

,e Pexp/(Pexp)SC ratio for PS-NB (0.94) is apparentlylower than 1.0.,is indicates that column constraint alone isnot quite enough to develop full composite action of the PEbeam regardless of the fact that plastic hinge rotation ca-pacity of PS-NB is no less than that of PS-SC.

,e Pexp/(Pexp)SC and θp/(θp)SC ratios of PS-MS are 0.97and 1.09, respectively. ,ey are higher than those for PS-NBspecimen. ,is indicates that the midspan stiffener is able toprovide extra constraint and develop higher degree ofcomposite action of the PE beam. However, the effectivenessmay diminish for longer beams.

,e Pexp/(Pexp)SC for PS-HS is 0.99 which is in the rangeof experimental error. In addition, the θp/(θp)SC is as high as1.17. Test data indicate that the plastic hinge zone stiffener isable to develop a very high degree of composite action and toenhance significantly the ductility of the PE beams. Usually,the length of the plastic hinge zone is in the range of 1.0 to1.5 times the beam depth, no matter how long the beam is.,erefore, the position of the end stiffener does not vary somuch, and the effectiveness of the plastic hinge zone stiffenerwill not diminish as the beam length becomes larger. Testresults indicated that the plastic hinge zone stiffener used inthis study has the potential to replace shear connectors ondeveloping the beam composite action.With the existence ofplastic hinge zone stiffener in the PE beam, less shearconnectors or shear studs are required to hold the concreteencasement between the beam’s webs; therefore it willsimplify the fabrication of PE beam.

3.5. Strengthened and Weakened Steel Beam-to-ColumnConnection. ,e θp that PS specimens achieved ranges from5.21 to 6.11% which is much greater than 4%. ,is isconsidered sufficient for seismic design of highly ductilemembers as required by AISC seismic provision [18]. ForPW specimens, although premature failure occurred, the θpachieved (4.52 to 4.75%) is also sufficient for beams in highlyseismic zones. Test results shows that the application of SBCand WBC on the PE beams worked satisfactorily. In addi-tion, designing SBC and WBC based on moment capacity ofthe H steel shape instead of the whole section seems to haveworked well for the specimens tested in this study.

,e average Pexp of PS specimens (69.3 kN) is 25% higherthan that of PW specimens (55.5 kN).,is phenomenon canbe attributed to three factors. ,e first factor comes from thebeam-to-column connection scheme itself. ,e usable de-sign beam end moment for SBC is 1.09 Mn, which is 17%higher than that of WBC (0.93 Mn). ,e influence of thisfactor will be reduced as the moment gradient of the beambecomes smaller. ,e second factor is the premature failureof the flange. And, the third factor is the concrete damagenext to the tapered flange.

Load

(kN

)Lo

ad (k

N)

–80

–60

–40

–20

0

20

40

60

80(a)

–0.08 –0.06 –0.04 –0.02 0 0.02 0.04 0.06 0.08Rotation (rad)

–80

–60

–40

–20

0

20

40

60

PW-NBPW-SC

PW-MSPW-HS

(b)

Figure 15: Skeleton curve of plastic hinge rotation for PW series. (a)Right plastic hinge rotation (θR). (b) Left plastic hinge rotation (θL).

o

P1

P2

P3

θ+yL θ+

uL

P

0.85P+peak

θL

P+peak

Figure 16: ,e definition of θu and θy.

10 Advances in Civil Engineering

Page 11: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

,e averaged θp value of PS specimens is 20% higherthan that of PW specimens. ,e premature fracture of theflange and the damage of the concrete next to the taperedflange make major contributions to this phenomenon.Providing sufficient “access hole-taper start clearance,” asshown in Figure 22, should be able to avoid prematurefailure of the flange.

For the PW specimens tested here, a “flange net widthwn” can be estimated according to the fracture path ob-served, as shown in Figure 23, and Section B4.3b of AISCspecification [16], as follows:

wn � 67 + 2 ×152

4 × 18.5� 73(mm). (2)

,e calculated wn equals to 73mm which is smaller thanthe flange gross width (75mm). ,is provides an explana-tion for the premature failure of the flange. It is suggestedthat, to prevent the premature failure of WBC, an accesshole-taper start clearance that ensures a net flange width wngreater than flange gross width should be provided.

,e concrete damage next to the tapered flange shouldcan be mitigated by removing the concrete in the tapered

(a) (b)

Figure 17: Damage of selected PS specimens. (a) Local buckling of the steel. (b) Fracture of the steel flange of specimen PS-NB.

(e)

(f)

(g)

(h)

Top view of WBC connection

(a)

(b)

(c)

(d)

Top view of SBC connection

Figure 18: Condition and crack pattern of all specimens at 1st 5% drift angle cycle. (a) PS-NB. (b) PS-SC. (c) PS-MS. (d) PS-HS. (e) PW-NB.(f ) PW-SC. (g) PW-MS. (h) PW-HS.

Advances in Civil Engineering 11

Page 12: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

flange area (termed as flange concrete herein), as the shadedregion indicated in Figure 19. ,is can be accomplished byinstalling thin steel plates in the area of tapered flange beforeconcrete is casted, as indicated in Figure 19(a).

,ick plate welding is considered to have adverseeffect on ductility development of strengthened beam-to-column connections. Since the PS specimens tested here

were small-scale specimens, the thick plate welding effect didnot show here. However, in the real structure, the thick platewelding effect is likely to emerge, and the ductility of thestrengthened connection may be reduced.

4. Conclusions

Eight partially concrete encased steel (PE) beams werefabricated and tested under earthquake type loading. ,eeffectiveness of midspan stiffeners and plastic hinge zonestiffeners in enhancing composite action and ductility of thePE beams was studied. ,e strength and ductility ofstrengthened beam-to-column connection and weakened

(a) (b)

Figure 20: Crack pattern of PS-NB and PW-NB at 2nd 2.5% drift angle cycle. (a) PS-NB. (b) PW-NB.

(a) (b)

Figure 21: Flange crack and fracture of specimen PW-NB. (a) Beginning of steel flange fracture. (b) Fracture of the steel flange.

Table 5: ,e effectiveness of concrete constraint schemes.

Specimen PS-NB PS-MS PS-HSPexp/(Pexp)SC 0.94 0.97 0.99θp/(θp)SC 1.04 1.09 1.17

Thin plate

Flange concrete

(a)

Flange concrete

(b)

Figure 19: Flange concrete of PW specimens. (a) Side view. (b) Top view.

12 Advances in Civil Engineering

Page 13: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

beam-to-column connection were also investigated. Basedon the experimental results reported herein, the followingconclusions can be drawn:

(1) �e plastic hinge zone sti�ener used in this study cansuccessfully develop the composite action of PEbeams. �e �exural strength of the beam can be fullydeveloped and the ductility of the beam was 17%higher than that of beams with shear connectors.�eplastic hinge zone sti�ener has the potential ofreplacing shear connectors for developing compositeaction of the beam.

(2) �e midspan sti�ener used in this study providescertain e�ect on developing composite action ofPE beams. However, the composite action de-veloped was less complete as the beams use shearconnectors.

(3) �e strengthened and weakened beam-to-columnconnections, which were used to enhance theductility of steel beams, can also be implemented inPE beams. �e ductility of the specimens tested is

high enough to be used in buildings in highlyseismic zones.

(4) Design of strengthened and weakened beam-to-column connection based on the cross-sectionalsteel shape alone, instead of the whole section, wasable to lead to high ductility of the beams. �is cangreatly simplify the design of strengthened andweakened beam-to-column connections of PEbeams.

(5) Premature �ange fracture may happen if the accesshole-taper start clearance is not long enough. It issuggested that an access hole-taper start clearancethat ensures a net �ange width greater than �angegross width should be provided.

(6) For beams with weakened beam-to-column con-nections, the concrete near the tapered �ange regionwas subjected to stress concentration and su�eredmore severe damage. �is brings more concretecracks, lower �exural strength, and low �exuralductility to the beams. �is phenomenon can bemitigated by removing the concrete next to the �angeat the �ange level.

Symbols

c′: Distance from the top of concrete to the neutralaxis of the composite section

fy: Yield stress of steelfu: Ultimate stress of steelLb: Length of the beam (refer Figure 11)Lc: Length between the column’s pinned connection

to the beam center (refer Figure 11)Lcs: Distance between the two critical section (refer

Figure 11)Ls: Distance between the columns (refer Figure 11)

150

Welding aaccess hole

End of welding access hole

Access hole-taper start clearance

Taper start

(a)

75

Taper start

25

35

End of weldingaccess hole

(b)

Figure 22: Access hole-taper start clearance of WBC. (a) Elevation view. (b) Top view.

30

15

6775

25

Fracture path

Figure 23: Observed �ange fracture path of specimen PW-NB(unit: mm).

Advances in Civil Engineering 13

Page 14: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

Mexp: Moment at the critical section corresponding toPexp

Mna: Nominal moment capacity is the moment capacityof whole composite section, based on actualmaterial strength

(Mna)c: Nominal moment capacity of critical sectionMnd: Design nominal flexural strength of the whole

section (composite section), based on nominalmaterial strength

Mpd: Design plastic moment of the steel shape, based onnominal material strength

(Mp)c: Plastic moment of the steel shape at criticalsection, based on actual material strength

P: Applied forceP+peak: Maximum load in the positive direction

P−peak: Maximum load in the negative directionPexp: Average of P+

peak and P−peak(Pexp)SC: Pexp of PS-SC specimenwn: Flange net widthα: Drift angleα+peak: Drift angle when reaching the maximum load in

the positive directionα−peak: Drift angle when reaching the maximum load in

the negative directionβ1: Coefficient for determining concrete stress block

height, based on ACI [16].c: Strength ratio Mexp/(Mna)cc′: Strength ratio Mexp/(Mp)cθL: Rotation of the left plastic hinge zonesθp: Plastic rotation(θp)SC: θp of PS-SC specimenθ+pL: Plastic rotation of left plastic hinge zone in positive

loading directionθ−pL: Plastic rotation of left plastic hinge zone in

negative loading directionθ+pR: Plastic rotation of right plastic hinge zone in

positive loading directionθ−pR: Plastic rotation of right plastic hinge zone in

negative loading directionθR: Rotation of the right plastic hinge zonesθu: Ultimate rotationθ+uL: Ultimate rotation of left plastic hinge zone in

positive loading directionθ+yL: Yield rotation of left plastic hinge zone in positive

loading directionθy: Yield rotationΔ: Lateral displacementΔy: Measured lateral displacement of the frame when

the moment at beam ends reached Mna.

Data Availability

,e data used to support the findings of this study areavailable from the corresponding author upon request.

Conflicts of Interest

,e authors declare that there are no conflicts of interestregarding the publication of this paper.

References

[1] C. C. Chen, T. Sudibyo, and Erwin, “Behavior of partiallyconcrete encased steel beam under cyclic loading,” In-ternational Journal of Steel Structures, pp. 1–14, 2018.

[2] A. Kodaira, H. Fujinaka, H. Ohashi, and T. Nishimura, “Fireresistance of composite beams composed of rolled steel profileconcreted between flanges,” Fire Science and Technology,vol. 23, no. 3, pp. 192–208, 2004.

[3] P. A. G. Piloto, A. B. R. Gavilan, L. M. R. Mesquita, andC. Goncalves, “High temperature tests on partially encasedbeams,” in Proceedings of 7th International Conference onStructure in Fire, Zurich, Switzerland, June 2012.

[4] P. A. G. Piloto, A. B. R. Gavilan, M. Zipponi, A. Marini,L. M. R. Mesquita, and G. Plizzari, “Experimental in-vestigation of the fire resistance of partially encased beams,”Journal of Constructional Steel Research, vol. 80, pp. 121–137,2013.

[5] R. Kindmann, R. Bergmann, L. G. Cajot, and J. B. Schleich,“Effect of reinforced concrete between the flanges of the steelprofile of partially encased composite beams,” Journal ofConstructional Steel Research, vol. 27, no. 1–3, pp. 107–122,1993.

[6] S. D. Nardin and A. L. H. C. Debs, “Study of partially encasedsteel composite beams with innovative position of stud bolts,”Journal of Constructional Steel Research, vol. 65, no. 2,pp. 342–350, 2009.

[7] J. Hegger and C. Goralski, “Structural behavior of partiallyconcrete encased composite sections with high strengthconcrete,” in Proceedings of 5th International Conference inComposite Construction in Steel and Concrete, pp. 346–355,Mpumalanga, South Africa, July 2004.

[8] Y. Chen, W. Li, and C. Fang, “Performance of partiallyencased composite beams under static and cyclic bending,”Structures, vol. 9, pp. 29–40, 2017.

[9] J. Lindner and N. Budassis, “Lateral torsional buckling ofpartially encased composite beams without concrete slab,”in Proceedings of Composite Construction in Steel andConcrete IV Conference, pp. 117–128, ,e United Engi-neering Foundation ASCE, Banff, AB, Canada, May-June2000.

[10] A. Plumier, “Behavior of connections,” Journal of Construc-tional Steel Research, vol. 29, no. 1–3, pp. 95–119, 1994.

[11] S. J. Chen, C. H. Yeh, and J. M. Chu, “Ductile steel beam-to-column connection for seismic resistance,” Journal ofStructural Engineering, vol. 122, no. 11, pp. 1292–1299,1996.

[12] S. J. Chen, J. M. Chu, and Z. L. Chou, “Dynamic behavior ofsteel frames with beam flanges shaved around connection,”Journal of Constructional Steel Research, vol. 42, no. 1,pp. 49–70, 1997.

[13] T. Kim, A. S. Whittaker, A. S. J. Gilani, V. V. Bertero, andS. M. Takhirov, “Cover-plate and flange-plate steel moment-resisting connections,” Journal of Structural Engineering,vol. 128, no. 4, pp. 474–482, 2002.

[14] E. A. Sumner and T. M. Murray, “Behavior of extended end-plate moment connections subject to cyclic loading,”Journal of Structural Engineering, vol. 128, no. 4, pp. 501–508, 2002.

[15] T. Sudibyo and C. C. Chen, “,e effect of intermediatestiffeners on steel reinforced concrete beam behavior,” WorldAcademy of Science, Engineering and Technology, In-ternational Journal of Civil and Environmental Engineering,vol. 6, no. 8, 2012.

14 Advances in Civil Engineering

Page 15: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

[16] ANSI/AISC 360-16, Specification for Structural Steel Buildings,American Institute of Steel Construction, Chicago, IL, USA,2016.

[17] ACI, Building Code Requirement for Structural Concrete ACI318-99, American Concrete Institute, Farmington Hills, MI,USA, 2014.

[18] ANSI/AISC 341-16, Seismic Provision for Structural SteelBuildings, American Institute of Steel Construction, Chicago,IL, USA, 2016.

Advances in Civil Engineering 15

Page 16: Effect of Intermediate Stiffeners on the Behaviors of ...downloads.hindawi.com/journals/ace/2018/8672357.pdfResearchArticle Effect of Intermediate Stiffeners on the Behaviors of Partially

International Journal of

AerospaceEngineeringHindawiwww.hindawi.com Volume 2018

RoboticsJournal of

Hindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com Volume 2018

Active and Passive Electronic Components

VLSI Design

Hindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com Volume 2018

Shock and Vibration

Hindawiwww.hindawi.com Volume 2018

Civil EngineeringAdvances in

Acoustics and VibrationAdvances in

Hindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com Volume 2018

Electrical and Computer Engineering

Journal of

Advances inOptoElectronics

Hindawiwww.hindawi.com

Volume 2018

Hindawi Publishing Corporation http://www.hindawi.com Volume 2013Hindawiwww.hindawi.com

The Scientific World Journal

Volume 2018

Control Scienceand Engineering

Journal of

Hindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com

Journal ofEngineeringVolume 2018

SensorsJournal of

Hindawiwww.hindawi.com Volume 2018

International Journal of

RotatingMachinery

Hindawiwww.hindawi.com Volume 2018

Modelling &Simulationin EngineeringHindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com Volume 2018

Chemical EngineeringInternational Journal of Antennas and

Propagation

International Journal of

Hindawiwww.hindawi.com Volume 2018

Hindawiwww.hindawi.com Volume 2018

Navigation and Observation

International Journal of

Hindawi

www.hindawi.com Volume 2018

Advances in

Multimedia

Submit your manuscripts atwww.hindawi.com