Technical Specifications
GeneralImaging Mode
Gray Scales
Display
Probe Frequence
Probe Connector
Beam-forming
Scanning Angle
Scanning Depth (mm)
Imaging ProcessingPre-processing
Post-processing
FunctionsCine Loop
Storage Media
Build-in Storage
Body Mark
B, B+B, 4B, B+M, M
256
15" LCD Monitor
2-10MHz
3 Sockets
DBF, DRA, DFS, DRF, RDF
From 30 to 150 Degree (depending on transducers)
From 40 to 250 (depending on transducers)
Pre-settings
Dynamic Range
Edge Enhancement
Frame Correlation
Line Correlation
Line Density
8-segment TGC Adjustment
4-focus Adjustment
Tissue Harmonic Imaging (THQ
Tissue Specific Imaging (TSQ
Pseudo Color
Grey Transform
Gamma Correction
Rejection
Left-right Reverse
Up-down Reverse
Polarity Reverse
21 Levels Depth Adjustment
Partial Zoom
Real-time Histogram
PIP (Picture in Picture)
365 Frames Bi-directional Cine-loop
External Flash Stick, CD/DVD-R¡W
Mass Storage (Min. 250G) and 16 Frames Snapshot
100 Types
Transducer Auto-detection
10-Segment Acoustic Power Output Adjustment
B-mode
Measurement & CalculationDistance, Circumference/perimeter, Area, Volume,
Angle, Hip Joint, Stenosis Ratio
M-mode
Software Packages
Distance, Time, Velocity, EF Slope, Heart Rate
Abdomen, Gynecology, Obstetrics, Urology, Small Parts,
Cardiology, Fetal Heart
Display
Date, Week, Time, Patient ID No., Patient Name, Doctor Name, Hospital Name,
Probe Model, Probe Position, Probe Frequency, Depth, Focus Position, Frame Rate,
Gain, Acoustic Output, Frame Correlation, Line Correlation, Edge Enhancement,
Dynamic Range, Gamma Correction, Body Mark, Character Note, Measurement
Values, Angle, Zoom, etc.
OthersPeripheral Ports 1 Video Output
1 VGA Port
2 USB Ports
DICOM 3.0
AC 1l0-240V SO/60Hz
420(W) x 465(L) x 1280(H)
Power Supply
Dimensions (mm)
Standard ConfigurationsEMP-2800 Main Unit
15" LCD Monitor
3 Transducer Connectors
2 USB Ports
Automatic Diagnostic Report Browsed, Saved and Printed
Measurement & Calculation Software Packages
Electronic Convex Array Probe (2.5-5.0MHz)
OptionsElectronic Linear Array Transducer (5.0-7.5MHz)
Electronic Linear Array Transducer (5.0-1O.0MHz)
Electronic Micro-convex Array Transducer (2.5-5.DMHz)
Electronic Micro-convex Array Transducer (5.0-7.5MHz)
Electronic Transvaginal Array Transducer (5.0-7.5MHz 1200
Electronic Transvaginal Array Transducer (5.0-9.0MHz 1500
PC Processor With Image/Character Management System
Min. 250 GB Hard Disk (MSF. Mass Storage)
Video Printer & Laser Printer
Needle-guided Biopsy
Footswitch
Flash Stick
DICOM 3.0
CD/DVD-R/W
Scanning Angle)
Scanning Angle)
DISTRIBUTORShenzhen Emperor Electronic Technology CO.. Ltd.Add: 2&3/F, Building 15, No. 1008 Songbai Road, Nanshan District, Shenzhen, 518108, China
Tel: +86-755-26073285,27657246,26415597 Fax: +86-755-26073886
E"mail: [email protected] Http://www.china-emperor.com