ON OFF - turns the system on/off ON OFF - turns the ioniser and heater on/off 100m³/h Eco Fresh 05 is a supply and heat recovery ventilation unit with quiet and discrete operation and unique combination of four key features in one easy to use system: Draws in and thoroughly filters fresh outside air in your premises; Heats up the fresh air inflow to room temperature; Ionizes the heated and filtered fresh air; Reduces excess indoor humidity, preventing mildew and mold growth; Eco Fresh 05 is a better and healthier approach to ventilation of your home and office. The heated and filtered air is also ionized which kills pathogenic microorganisms providing both antiseptic and refreshing effect to your environment. The healthier microclimate and clean air is essential for improvement in health of asthma and allergy sufferers, while also being an important factor for regaining body energy and general indoor air quality. long life systems 11.2. Switches: TECHNICAL DATA Dimensions: minimum wall thickness 25 cm. 9 8 2á 7 10 11 6 5 4 3 2a 1 ON OFF 11.1 11.2 Inside Grille Outside Grille „ECO - FRESH 03 „ „ECO - FRESH 03 „ It cannot be stressed enough how important is ventilation for every home or occupational work environment where most people spend 90% of their lives. Good ventilation is as important for the premises we live and work in, as fresh air is a necessity for our good health. The levels of insulation of our homes and the central heating systems in place lead to potentially lessoning of home ventilation. In cold days or in polluted areas it is not easy to provide good natural ventilation , while often results in opening the window or door allowing the cold and polluted air to enter the premises. SUPPLY AND HEAT RECOVERY VENTILATION UNIT 1. Extermal grille - protects the system from moistening even in heavy rains. 2. Filter: Activated charcoal filter - ensures fresh and filtered airflow in the premises even bacteria etc. Fine filter - used in very dusty areas In very polluted areas the filter should be changed two to three times a year. Positioning the filter - 2à (when you have direct access to the system from the outside), or 2b (when access is possible only from inside the premises). 3. Metal Shutter prevents the inflow of cold air when the unit is switched off. 4. Duct the duct length is adjustable according to the wall thickness. 5. Heater 420W – cost effective heater designed for intermitted operation. .Achieves ?t (the temperature difference between the outside air and the air inflowing into the premises) 40º C when operating at supply rate 100 m³/h. 6. Thermostat - controls the heating element to guarantee inflowing fresh air at 23°C room temperature When the temperature of the inflowing air is above 17°Ñ , the heating element will remain switched off. 7. Thermal cut-out - protects the system from overheating. 8. Ionizer - disinfects and cleans the air from dust and debris that can be harmful to breath or aggravate allergies. Prevents the formation of mould and mildew. 9. Fan - Equipped with five speed regulator to control the air inflow from 30m³/h (silent night mode) to120m³/h (day mode). 10. Decorative grille - can be white, Inox, Chrome or other colours. 11. Control panel – includes controller, switches, humidity control system and timer. Humidity Control System and Timer - adjusts fan speed according to humidity levels. Ensures system operationwhen the humidity is above 70%. -1 11.1.Controller – smoothly changes fan speed from 900min to -1 3 3 2650min while adjusting the air inflow from 30m /h to 100m /h. Rated Voltage Power Consumption Maximum rotational speed Maximum Flow Hz/V W W min -1 m /h 3 fan heater 50/220 18 420 2650 100 03 Model 2,7 IP Kg Weight 44 Protection Degree

Upload: others

Post on 14-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: eko 16092010-Englisheurostarhomesystems.com/uploads/3/4/4/8/34481448/eco-fresh_03_05.pdfeko_16092010-English Author: george Created Date: 4/28/2011 5:05:59 AM

ON

OFF- turns the system on/off

ON

OFF- turns the ioniser and heater on/off

100m³/h

Eco Fresh 05 is a supply and heat recovery ventilation unit with quiet and discrete operation and unique combination of four key features in one easy to use system:• Draws in and thoroughly filters fresh outside air in your premises;• Heats up the fresh air inflow to room temperature; • Ionizes the heated and filtered fresh air; • Reduces excess indoor humidity, preventing mildew and mold growth; Eco Fresh 05 is a better and healthier approach to ventilation of your home and office. The heated and filtered air is also ionized which kills pathogenic microorganisms providing both antiseptic and refreshing effect to your environment. The healthier microclimate and clean air is essential for improvement in health of asthma and allergy sufferers, while also being an important factor for regaining body energy and generalindoor air quality.

long life systems

11.2. Switches:

TECHNICAL DATA

Dimensions: minimum wall thickness 25 cm.

9 82á 7 10

1165432a1

ON

OFF

11.1 11.2

Inside Grille

Outside Grille

„ECO - FRESH 03 „„ECO - FRESH 03 „ It cannot be stressed enough how important is ventilation for every home or occupational work environment where most people spend 90% of their lives.

Good ventilation is as important for the premises we live and work in, as fresh air is a necessity for our good health. The levels of insulation of our homes and the central heating systems in place lead to potentially lessoning of home ventilation.

In cold days or in polluted areas it is not easy to provide good natural ventilation , while often results in opening the window or door allowing the cold and polluted air to enter the premises.

SUPPLY AND HEAT RECOVERY VENTILATION UNIT

1. Extermal grille - protects the system from moistening even in heavy rains.

2. Filter: Activated charcoal filter - ensures fresh and filtered airflow in the premises even bacteria etc.• Fine filter - used in very dusty areasIn very polluted areas the filter should be changed two to three times a year.

Positioning the filter - 2à (when you have direct access to the system from the outside), or 2b (when access is possible only from inside the premises).

3. Metal Shutter – prevents the inflow of cold air when the unit is switched off.

4. Duct – the duct length is adjustable according to the wall thickness.

5. Heater 420W – cost effective heater designed for intermitted operation..Achieves ?t (the temperature difference between the outside air and the air inflowing into the premises) 40º C when operating at supply rate 100 m³/h.

6. Thermostat - controls the heating element to guarantee inflowing fresh air at 23°C room temperature When the temperature of the inflowing air is above 17°Ñ , the heating element will remain switched off.

7. Thermal cut-out - protects the system from overheating.

8. Ionizer - disinfects and cleans the air from dust and debris that can be harmful to breath or aggravate allergies. Prevents the formation of mould and mildew.

9. Fan - Equipped with five speed regulator to control the air inflow from 30m³/h (silent night mode) to120m³/h (day mode).

10. Decorative grille - can be white, Inox, Chrome or other colours.

11. Control panel – includes controller, switches, humidity control system and timer.

Humidity Control System and Timer - adjusts fan speed according to humidity levels. Ensures system operationwhen the humidity is above 70%.

-111.1.Controller – smoothly changes fan speed from 900min to-1 3 32650min while adjusting the air inflow from 30m /h to 100m /h.

Rated Voltage Power Consumption Maximum rotational speed

Maximum Flow

Hz/V W W min-1

m /h3

fan heater

50/220 18 420 265010003

Model

2,7

IP Kg

Weight

44

Protection Degree

Page 2: eko 16092010-Englisheurostarhomesystems.com/uploads/3/4/4/8/34481448/eco-fresh_03_05.pdfeko_16092010-English Author: george Created Date: 4/28/2011 5:05:59 AM

12

7 8 93xM5 10

6 115432à

2?

1

120m³/h

Contacts

www.mmotors-bg.com

Golden Medal

IFPINTERNATIONAL TECHNICAL FAIR

PATENT No1813

„ECO - FRESH 05 „„ECO - FRESH 05 „

SUPPLY AND HEAT RECOVERY VENTILATION UNIT

1.

2. Filter: •

• .

Positioning the filter - 2à (when you have direct access to the system from the outside), or 2b (when access is possible only from inside the premises).

3. Metal Shutter – prevents the inflow of cold air when the unit is switched off.

4. Duct – the duct length is adjustable according to the wall thickness.

5. ?t

the premises) 40º C when operating at supply rate 100 m³/h.

Extermal grille - protects the system from moistening even in heavy rains.

Activated charcoal filter - ensures fresh and filtered airflow in the premises evenin heavy polluted urban and industrial areas. Thoroughly clears the air from smells, dust, burnt gas,bacteria etc.

Fine filter - used in very dusty areasIn very polluted areas the filter should be changed two to three times a year.

Heater 420W – cost effective heater designed for intermitted operation. Achieves the (temperature difference between the outside air and the air inflowing into

IMPORTANT!When the outside temperature is below -12°C it is necessary to reduce the speed ofthe fan in order to guarantee inflowing air with room temperature 23°C.

.

7.

8. .

9. Fan - Equipped with five speed regulator to control the

10. Humidity Control System - controls the humidity by keeping it below 70%.

11.

12. Remote Control:

6. 17°Ñ

Thermostat - controls the heating element to guarantee inflowing fresh air at 23°Croom temperature When the temperature of the inflowing air is above , the heating element will remain switched off.

Thermal cut-out - protects the system from overheating

Ionizer - disinfects and cleans the air from dust and debris that can be harmful tobreath or aggravate allergies. Prevents the formation of mould and mildew

air inflow from 30m³/h (silent night mode) to 120m³/h (day mode).

Decorative grille - can be in white, inox, chrome or other colours.

START - Turns the system on;

- Turns the system off;

– The standby button will stop the system, but will keep it in state of readiness. The humidity control system and timer is live and will startthe fan and ionizer when the humidity reaches over 70%. The built-in timer ensures operation for 10 minutes after the humidity falls below 70%.

FAN SPEED – 5 Speed control panel. At speed 1 the fan operates silently 3 at 30m/h extraction rate suitable for nighttime operation. At Speed 5 the fan

3 operates at its maximum rate 120m/h, suitable for daytime operation.

- Switch ON the Ionizer. - Switch OFF the Ionizer.

- Switch ON inflowing air heater; - Switch OFF inflowing air heater;

STOP

Standby

ON OFF

ON OFF

ON OFF

- Switch ON Humidity Control System; - Switch OFF Humidity Control System;

GreenRed

BlueOrange

LED LIGHTS

- When the orange LED glows steady, theHumidity Control System and Timer is ON;- When the LED blinks, the humidity is above 75%.

Orange LED:

Blue LED:

Dimensions: Minimum wall thickness 32 cm.

- When the blue LED glows, the Ioniser is operating.

Upon customer's request, the unit can be manufactured to fit for wall thickness of 17 cm.

Fig. 2à

Filter

Fig. 2

Outside Grille Wall mountInside Grille

Filter

Rated Voltage Power Consumption Maximum rotational speed

Maximum Flow

Hz/V W W min-1

m /h3

fan heater

50/220 46 420 265012005

Model

3,1

IP Kg

Weight

44

Protection Degree

Green LED:- When the green LED blinks, the unit is switched OFF;- When the LED glows steady, the unit is switched ON.

Red LED:- When the red LED glows steady, the unit is in state of readiness to startheating the inflowing air if it drops below 17°Ñ.- When the LED blinks, the inflowing air is below 17C0 and the heaterstarts operating.

Note

à) When the system is activated from the Standby button, the green, orange and blue LEDs glow. The system is now in state of readiness to start operating when the humidity reaches above 70%. When the humidity increases above these values, the fan starts operating on speed 3 together with the ionizer. The sensor continues to monitor the humidity and automatically turns them off 5 min. after the humidity drops below 70%.

b) The heater can be switched on by the remote control and it will start heatingthe inflowing air when its below 17°Ñ.

c) You can choose your own combination of options from the remote control.