ABBREVIATIONS
LEGEND, NOTES &
LC11 - ELECTRICAL
KBE-0005 KBE-0005
GENERAL NOTES
A0
DRAWING SCALEPLOT SCALEOLD DWG NO. SHEET OF
DRAWING NO.FILE NAMEFWR NO.
DATE
EQT CODE
APPROVED
ENGINEER
PLANNING
SAFETY
CROSSCHECK
DRAWN
CHECKED
REV. NO. REVISION DESCRIPTION APPROVED DATE
Lachish Campus
Qiryat Gat 82109, Israel
R
Intel Israel
P.O. Box 82
IT
IS
U
ND
ER
T
HE
V
EN
DO
RS
R
ES
PO
NS
IB
IL
IT
Y A
ND
S
CO
PE
O
F W
OR
K T
O C
HE
CK
G
IV
EN
M
EA
SU
RE
ME
NT
S A
ND
E
LE
VA
TIO
NS
O
N S
IT
E B
EF
OR
E P
RE
FA
BR
IC
AT
IO
N!!
NO
TE
:
F28/F28A PROJECT ENGINEERING
INTEL CORPORATION.
THIS DRAWING CONTAINS
INFORMATION WHICH IS THE
C
HENSEL PHELPS
A THIS IS A STANDARD LEGEND SHEET. SOME SYMBOLS OR ABBREVIATIONS MAY APPEAR ON
THIS SHEET AND NOT ON THE PROJECT DRAWINGS.
B CONDUCTORS SIZED ON THE BASIS OF XLPE INSULATED COPPER TO IEC 502. MAXIMUM
CONDUCTOR TEMPERATURE OF 90°C. 30°C AMBIENT TEMP INDOORS, 45°C AMBIENT TEMP
OUTDOORS IN THE SHADE, 20°C SOLAR TEMP GAIN IF NOT IN THE SHADE AND A GROUND
TEMPERATURE OF 20°C.
C MOUNTING PER SPECIFICATIONS UNLESS OTHERWISE INDICATED.
D EQUIPMENT IS GENERAL PURPOSE PER SPECIFICATION UNLESS OTHERWISE INDICATED AS
FOLLOWS: X=EXPLOSION PROTECTED, EX CLASSIFICATION PER IEC 79
WP=WEATHERPROOF, IP CLASSIFICATION PER IEC 529.
E SEE ELEMENTARY DIAGRAMS FOR OPERATIONAL SCHEMATICS.
F LUMINAIRE SYMBOLS SHOWN ARE GENERIC GRAPHIC REPRESENTATIONS. REFER TO
LUMINAIRE SCHEDULE FOR SPECIFIC SOURCE, TYPE & MOUNTING.
G SYSTEMS INCLUDING ELECTRICAL CIRCUITS SHOULD BE TESTED BY AUTHORIZED INTEL
INSPECTOR ("BODEK").
H CONSTRUCTION DETAILS SHOWN ON THE 7600 SERIES DRAWINGS SHOW TYPICAL
INSTALLATION UNLESS OTHERWISE NOTED, AND APPLY TO ELECTRICAL WORK INCLUDED IN
THE SUMMARY OF WORK FOR THIS PACKAGE EVEN THOUGH NOT SPECIFICALLY
REFERENCED ON THE PLAN DRAWINGS.
J IN EXISTING DISTRIBUTION BOARD, WHERE PLUG-IN CIRCUIT BREAKER TYPE IS REQUIRED,
THE BASE OF THE CIRCUIT BREAKER IS ALREADY INSTALLED.
K ACQUIRE AMC APPROVAL FOR EQUPIMENT THAT IS TO BE LOCATED IN THE CLEAN AIR
STREAM.
L PROVIDE UV PROTECTION FOR EQUIPMENT LOCATED OUTDOORS.
M PROVIDE TYPE C MINICIRCUIT BREAKER FOR EQUIPMENT FED FROM BRANCH PANELS
UNLESS OTHERWISE NOTED.
N CABLES BELOW 50 SQUARE MILLIMETERS ROUTED IN TRAY TO BE FIELD ROUTED.
P FOR CIRCUITS REQUIRING PENETRATIONS, VERIFY FIRE RATING OF ASSEMBLY. APPLY FIRE
STOPPING AS REQUIRED PER SPECIFICATION 07_84_00_00(07840).
0 ISSUED FOR MODELING DE 06/26/14
1 ISSUED FOR MODELING DE 08/21/14
NAME: KBE-0005.DWG USER: Sparkman, Richard/PDX DATE: 10/9/2014 4:14 PM
TRACK LIGHTING
#
A
#
A
#
A
RECESSED DOWN LIGHT
a 10r
A
300mm X 600mm FLUORESCENT LUMINAIRE
10r
a
A
WALL MOUNTED LUMINAIRE
600mm X 1200mm FLUORESCENT LUMINAIRE
SURFACE OR PENDANT MOUNTED LUMINAIRE
THE NUMBER INDICATES PHASE. UPPER CASE LETTER INDICATES
STAND ALONE LOWER CASE LETTER INDICATES SWITCH CONTROLLING
LUMINAIRE TYPE FROM LUMINAIRE SCHEDULE. HATCHING OR UPPER
CASE "EM" = EMERGENCY LUMINAIRE, "UPS" = UPS BACK-UP
LAMP. NUMBER INDICATES CIRCUIT. LOWER CASE LETTER FOLLOWING
INDICATED BY SHADED SECTION
STRIP FLUORESCENT LUMINAIRE
600mm X 600mm FLUORESCENT LUMINAIRE
300mm X 1200mm FLUORESCENT LUMINAIRE
UNLESS OTHERWISE NOTED
PHOTOELECTRIC LIGHTING CONTROL UNIT-SENSOR AIMED NORTH
EXIT LIGHT-CEILING OR WALL MOUNTED-DIRECTION ARROW AS
INDICATED. TYPE PER LUMINAIRE SCHEDULE. FACE OF SIGN
A
10ra
EM
10r
a
A
10ra
A
A
10r
OR
MD
PC
a
A
10r
a
10r
A
10r
A
a
10r
A
10r
A
CONT CONTINUED
CABLE TRAY, LADDER TYPE
CABLE TRENCH
KILOWATT HOUR DEMANDkWHD
PM POWER MONITOR
(FORTY NINE) OVERTEMP RELAY49
SUB SUBSTATION
CUBICLECUB.
FE-G = IRON REBAR GROUND LOOP CONDUCTOR
FE-G
F = 400V FACILITIES DISTRIBUTION PANEL
XXX = AMPS FRAME SIZE
XXX
ISOLATOR MEDIUM VOLTAGE, DRAW-OUT TYPE
CONTROL SWITCHCS
SQUARE MILLIMETERSmmÀ2
020FEF1AA12
N = NORMAL
BUILDING
F = FAB
P = PROJECT BUILDING/WAREHOUSE
H = HAZARDOUS MATERIALS BUILDING
C = CUB
O = MSB
S = SITE/MAIN SUBSTATION
FLOOR:
1 = UTILITIES
0 = UNDERGROUND
6 = ROOF
5 = UPPER FAN-DECK
4 = INTERSTITIAL/FAN-DECK
3 = CLEANROOM
X = 208V TOOL DISTRIBUTION PANEL
XLPE CROSS LINKED POLYETHELENE INSULATED
SWA STEEL WIRE ARMORED
LS LEVEL SWITCH
IPS
IP DEGREE OR ENCLOSURE PROTECTION
INTERRUPTABLE POWER SUPPLY
EXP EXPLOSION PROOF
AWA ALUMINUM WIRE ARMORED
KVA, PRIMARY & SECONDARY VOLTAGE INDICATED
RATINGS PER SPECIFICATIONS AND/OR ONE-LINE DIAGRAM
80E
LIGHTNING PROTECTION AIR TERMINAL SPIKE
* LOWER CASE LETTER DENOTES SWITCH LEG
FLUSH MTD IN FLOOR, 16A, 1Ø
UNDER OTHER DIVISIONS
RACEWAY (TRUNKING/TRAY) AND CONDUCTORS FURNISHED AND
DEVICE FURNISHED AND INSTALLED UNDER OTHER DIVISIONS.
INSTALLED UNDER THIS SECTION. CONDUCTOR TERMINATIONS
RVSS REDUCED VOLTAGE SOFT START
STANDBYSTBY
WW WIRE WAY
UTILITY COMPANY SERVICE CONDUITS
U
ENCLOSED STARTER, ADJUSTABLE FREQUENCY DRIVE (AFD)
EQUIPMENT TYPE
M = 400V MOTOR CONTROL CENTER
LOCATION (NORTH\EAST CORNER)
C = CPS
ELECTRICAL PANEL NUMBERING SYSTEM
S = 400V TOOL DISTRIBUTION PANEL
L = 400/230V FACILITIES LIGHTING & RECEPTACLES
SERVICE
SEQUENTIAL PANEL NUMBER 1 THRU 999
E = EMERGENCY
AFD
ABBREVIATIONS DESCRIPTION
NEW
NEUTRAL
INSTALLED
NAMEPLATE
ON-OFF
POWER
INSTALLED
PHASE
PANEL
PHOTOCELL
QUANTITY
RACEWAY
RELOCATE
REDUNDANT
ROOM
REQUIRED
SPEAKER
SECONDS
SPARE
SURFACE
SWITCH
STANDARD
TIME CLOCK
TYPICAL
WATT, WIRE
APPARATUS
REMOVE
IMPEDANCE, ZONE
POSITION SWITCH
NON-AUTOMATIC
NORMALLY CLOSED
NORTH EAST
NORTH WEST
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHT
OPEN POLE DETECTOR
ON-OFF-REMOTE
OVERLOAD RELAY
ON-OFF-AUTO
NOT IN CONTRACT
POWER QUALITY
PUSHBUTTON SWITCH
PERSONAL ID NUMBER
PILOT LIGHT
POLYVINYL CHLORIDE
RATE OF RISE, RIGHT
RECEPTACLE
ROOT MEAN SQUARE
RUNNING TIME METER
SWITCH OPERATOR
SOUTH EAST
SHORT CIRCUIT
RADIO FREQUENCY
POWER FACTOR
OWNER FURNISHED, CONTRACTOR
PLANT CONTROL PANEL
POST INDICATOR VALVE
OWNER FURNISHED, OWNER
NATIONAL ELECTRICAL CODE
REDUCED VOLTAGE NON-REVERSING
SERVICE ENTRANCE SUBSTATION
SLOW SPEED OL RELAY
SMOKE/FUME EXHAUST PANEL
REDUCED VOLTAGE REVERSING
RIGID GALVANIZED STEEL
SECURITY CONTROL PANEL
SYMMETRICAL
SWITCHBOARD
SWITCHGEAR
SOUTH WEST
SUPPRESSOR
TERMINAL BLOCK
TO BE DETERMINED
TIME DELAY RELAY
THERMOSTAT
SYNCHRONIZER
VOLT-AMPERE
VOLTMETER, VOLT
TAMPER SWITCH
VOLTMETER SWITCH
VAPORPROOF
WEATHERPROOF
AND GROUP AS NOTED
TRANSFORMER
WYE-CONNECTED
SOURCE TRANSFER CONTROL
UNINTERRUPTIBLE POWER SUPPLY
EXPLOSION PROOF - TYPE, CLASS
WATTHOUR DEMAND METER
WAFER STARTS PER WEEK
VERY EARLY SMOKE DETECTION
VERTICAL OUTSIDE BEND
VARIABLE FREQUENCY DRIVE
VERTICAL LAMINAR FLOW UNIT
VOLTAGE TRANSFORMER
VERTICAL INSIDE BEND
TWO SPEED, ONE WINDING
TWISTED SHIELDED PAIR
TWO SPEED, TWO WINDING
STAINLESS STEEL
(N)
N
NA
NEC
N.E.
N.C.
N.O.
NTS
NL
NP
OFCI
N.W.
OL
OO
OFOI
OPD
OOR
P
OOA
NIC
AB
AC
A, AMP
AFD
AFF
AIC
AF
ACB
ABBREVIATIONS
ABSOLUTE
AMMETER, AMPERE
ABOVE FINISHED FLOOR
AMPERE FRAME
ALTERNATING CURRENT
AIR CIRCUIT BREAKER
ARF
AS
AT
ATS
B
ATX
BKR
BG
BFF
BLDG
BOD
BOT
BOP
BOC
BMS
BC
AMP TRIP
BELL
BULK GAS
BUILDING
BREAKER
BOTTOM OF DUCT
BARE COPPER
ABOVE RAISED FLOOR
BELOW FINISHED FLOOR
BOTTOM OF CONDUIT
AMMETER SWITCH
AUTO TRANSFORMER
BOTTOM OF PIPE
BOTTOM OF TRAY OR TRUNKING
ANN ANNUNCIATOR
DESCRIPTION
ABBREVIATIONS
ADJUSTABLE FREQUENCY DRIVE
AUTOMATIC TRANSFER SWITCH
BUILDING MANAGEMENT SYSTEM
AMPS INTERRUPTING CURRENT
PCP
PL
PC
PB
PQ
PIV
PNL
, PH
PIN
PVC
QTY
RCY
(RD)
(R)
RCPT
R
RMS
RQD
RM
RGS
RVR
S
RVNR
RTM
SEC
SES
S.E.
SCP
SFEP
SOL
SP
SO
S.C.
RF
C
BT
CB
CC
CAP.
CCTV
CAT.
CCT
CPT
CO
CLK
CT
CRS
CRE
CRWP
CR
CAPACITOR
CIRCUIT
CATALOG
CIRCUIT BREAKER
BASIC TRANSPONDER
(ENGINEERING STUDY USE)
CONDUIT
CONTROL CABLE
CLOCK
CURRENT TRANSFORMER
CORROSION RESISTANT
CONDUIT ONLY
CONTROL RELAY
CLEANROOM WALL PANEL
DB
DC
DDC
DIA
E
DIV
EG
ECS
EDF
(E), EX
EMH
EMO
ELEC
EM,EMER
EL ELEVATION
DIAMETER
EMPTY
EXISTING
DIVISION
DUCT
ELECTRICAL
DELTA CONNECTED
EMERGENCY
ELECTRICAL MANHOLE
DUCT BANK
DIRECT CURRENT
DIRECT DIGITAL CONTROL
ENGINE GENERATOR
EMERGENCY MANUAL OFF
D
CLOSED CIRCUIT TELEVISION
COATED RIGID STEEL CONDUIT
EMERGENCY COMMAND STATION
ELECTRIC DRINKING FOUNTAIN
CONTROL POWER TRANSFORMER
PF
BRN BUS REFERENCE NO.
STD
SUR
SUPP
STC
SYM
S.W.
SWGR
SWBD
SW
2S1W
TSTAT
2S2W
TBD
TDR
TC
TB
SYNC
TYP
TSP
TS
V
VA
VESDA
UPS
VFD
VIB
VOB
VLF
VS
VT
W
VP
ENT
ERT
EOL
ESES
EWC
ETM
F
ET
(F)
FA
FBO
FACP
FDR
FLR
FU
FOL
FCS
FLUSH
FUTURE
FEEDER
FLOOR
FUSE
FAST ACTING OL RELAY
EXPANDED TRANSPONDER
END-OF-LINE DEVICE
FIRE ALARM
FURNISHED BY OTHERS
ELECTRIC WATER COOLER
FACILITY CONTROL SYSTEM
ELAPSED TIME METER
FVR
GND
FVNR
H
GSM
GFR
GFCI
GEN
HH
HOA
HID
HB
HVAC
GROUND
GENERAL
HANDHOLE
HORN
HORIZONTAL BEND
HAND-OFF-AUTOMATIC
GROUND FAULT RELAY
CONDITIONING
GAS SAFETY MONITOR
FULL VOLTAGE REVERSING
FWS FIRE WATER STORAGE
EMER SERVICE ENTRANCE SUBSTATION
GROUND FAULT CIRCUIT INTERRUPTER
HEATING, VENTILATING & AIR
HIGH INTENSITY DISCHARGE
EMERGENCY RESPONSE TEAM
FULL VOLTAGE NON-REVERSING
ELEC NON-METALLIC TUBING
FIRE ALARM CONTROL PANEL
X
WP
WSPW
WHD
XFMR
(X)
ZS
Z
Y
I.D.
I&C
IMC
IER
IS
K
J
I/O
kV
kVA
kW
kWH
L
kVAR
KILOVOLT
KEY INTERLOCK
INPUT/OUTPUT
JUNCTION BOX
IDENTIFICATION
CURRENT SWITCH
KILOWATT
KILOVAR
LEFT
KILOVOLT-AMPERE
KILOWATT HOUR
LC
LTG
LV
MBS
MAX
MCC
MCB
M
MCP
MDC
MH
MFR
MCCB
MO
MIN
MLO
MMP
MOTOR OPERATOR
LIGHTING
MAXIMUM
MINIMUM
MANHOLE
MAIN CIRCUIT BREAKER
LOW VOLTAGE
LIGHTING CONTACTOR
MAIN LUGS ONLY
MOTOR CONTROL CENTER
MANUFACTURER
LAN LOCAL AREA NETWORK
INTEGRATED EQUIPMENT RATING
INSTRUMENTATION AND CONTROL
INTERMEDIATE METALLIC CONDUIT
MECHANICAL MOUNTING PANEL
MOTOR CIRCUIT PROTECTOR
MOTORIZED DAMPER CONTROL
MAG CONTACTOR, COIL OR CONTACT
MAINTENANCE BYPASS SWITCH
MOLDED CASE CIRCUIT BREAKER
ICCB INSULATED CASE CIRCUIT BREAKER
MSP
MT,MTD MOUNT, MOUNTED
MOTOR STATER PANEL
MS MOTOR STARTER
SS
EMT ELEC METALLIC TUBING
DM
PQM
DISPLAY METER (DM)
POWER QUALITY MONITOR (PQM)
K
EMH
2
400
100/M
0L
?
CR
# #
CONTROL RELAY OR MOTOR CONTACTOR COIL
ELECTRICAL LEGEND
PROTECTOR). FRAME SIZE SHOWN, 3 POLE UNLESS OTHERWISE INDICATED
CIRCUIT BREAKER, MAGNETIC TRIP ONLY (MOTOR CIRCUIT
STARTER, SIZE INDICATED, W/OVERLOADS
ELECTRICAL MANHOLE
NO CONNECTION
CONNECTION AS INDICATED
MEDIUM VOLTAGE CABLE TERMINATION
KEYED INTERLOCK SWITCH
630
400
100
30
GROUND (EARTH)
0-600
V
10
KVA500
10KV
380Y/220V
FUSED SWITCH, SWITCH CURRENT RATING INDICATED,
3 POLE UNLESS OTHERWISE INDICATED
SWITCH AND SCALE RANGE AS INDICATED
CIRCUIT BREAKER MEDIUM VOLTAGE, DRAW-OUT TYPE
CIRCUIT BREAKER, SOLID STATE TRIP, PLUG-IN TYPE
METER WITH SWITCH (V=VOLTMETER, A=AMMETER)
CAPACITOR-KVA INDICATED, 3 PHASE UNLESS OTHERWISE INDICATED
TRANSFORMER
SURGE ARRESTOR
CIRCUIT BREAKER; THERMAL MAGNETIC OR SOLID STATE TRIP. 3 POLE
UNLESS OTHERWISE INDICATED
XX
XX
ON ONE-LINE DIAGRAM
EQUIPMENT TAG NUMBER
CONDUCTORS AND CONNECTIONS UNDER THIS DIVISION.
OR EQUIPMENT SCHEDULE
MOUNTED AS INDICATED
PANELBOARD - SURFACE OR FLUSH MOUNTED AS INDICATED
MAJOR ELECTRICAL EQUIPMENT OR DEVICE, I.E., MOTOR CONTROL
CONNECTION POINT TO EQUIPMENT SPECIFIED, SUPPLIED, AND
MOTOR CONNECTION. FOR KW SIZE, REFER TO ONE-LINE DIAGRAM
TERMINAL JUNCTION BOX (TJB). SURFACE OR FLUSH
CENTER, SWITCHBOARD, ETC
K = KEY OPERATED
LV = LOW VOLTAGE
P = PILOT LIGHT
WP = WEATHER PROOF
32A 3PH
D = DIMMER
2
63
40
30
100
125
F
CB
63 = SWITCH AMPERAGE); "ON-LOAD" RATED
M = MANUAL MOTOR STARTER SWITCH
FUSED DISCONNECT SWITCH (40/63, 40 = FUSE AMPERAGE,
100 = TRIP AMPERAGE, 125 = FRAME AMPERAGE); "ON-LOAD" RATED
WALL SWITCH, SUBSCRIPT INDICATES TYPE:
AND AMPERAGE AS INDICATED
IG=ISOLATED GROUND, X=HAZARDOUS RATED
TWIN CONVENIENCE RECEPTACLE (SOCKET OUTLET)
RECEPTACLE (SOCKET OUTLET), SPECIAL PURPOSE NEMA CONFIGURATION
FACE, TWIN WITH TELEPHONE OR DATA AS INDICATED
CONVENIENCE RECEPTACLE (SOCKET OUTLET) - SINGLE, TWIN, 16A, 1Ø
X = HAZARDOUS RATED
4 = FOUR WAY (INTERMEDIATE)
3 = THREE WAY (TWO WAY)
2 = DOUBLE POLE
INSTALLED UNDER OTHER DIVISIONS. RACEWAY (TRUNKING/TRAY),
NONFUSED DISCONNECT SWITCH, AMPERAGE INDICATED; "ON-LOAD" RATED
ENCLOSED CIRCUIT BREAKER WITH SHORT CIRCUIT AND OVERCURRENT
CONVENIENCE RECEPTACLE (SOCKET OUTLET), PEDESTAL, TWIN SINGLE
EMERGENCY/STANDBY ENGINE GENERATOR. RATING AS INDICATED
PROTECTION. SEE SPECIFICATION FOR TYPE OF TRIP. (100/125,
WP=WEATHER PROOF, GFCI=GROUND FAULT CIRCUIT INTERRUPTER,N
L
400
E
RESISTOR
400:5
(?)
A
(?)
800:5
4:1
?
CURRENT TRANSFORMER. RATIO & QUANTITY INDICATED
INDICATING LIGHT, WALL MTD, LETTER INDICATES COLOR
(A=AMBER, G=GREEN, R=RED)
RATIO, QUANTITY, AND CONNECTION INDICATED
INSTRUMENTATION VOLTAGE TRANSFORMER
AUTOMATIC TRANSFER SWITCH
CONTINUOUS CURRENT RATING AS INDICATED
R
# #
?
#
I/O
#
#
OFF
# 0X
ON
O
#
#
H
# X00
# 00X
000
A
INDICATING LIGHT, PANEL MTD, LETTER INDICATES COLOR
INDICATING LIGHT, PUSH-TO-TEST, LETTER INDICATES COLOR
(A=AMBER, G=GREEN, R=RED)
(A=AMBER, G=GREEN, R=RED)
NORMALLY OPEN I/O CONTACT WITH ADDRESS
SELECTOR SWITCH, MAINTAINED CONTACTS
3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS
O=OPEN CONTACT
X=CLOSED CONTACT
O=OPEN CONTACT
X=CLOSED CONTACT
PUSH-TEST
#
#
R
#
GROUND SENSOR CURRENT TRANSFORMER. RATIO & QUANTITY INDICATED
?
##
?
# #
O
?
?
X1 X2
H1
#
H2
#
?
?
?V
?VA
OL
# #
NORMALLY OPEN RELAY CONTACT
DELTA-WYE
OVERCURRENT DEVICE (OCD), OVERCURRENT RELAY (OCR) OR
NORMALLY CLOSED RELAY CONTACT
CONTROL POWER TRANSFORMER
MOTOR OVERLOAD
OPEN-PHASE DETECTION RELAY (OPD)
I/O
?
# #
NORMALLY CLOSED I/O CONTACT WITH ADDRESS
J= WALLJ
30
2
2
J
UP
= FLOOR
UNDERSLAB OR BELOW GRADE CONDUIT DUCT BANK
WIREWAY, AUX GUTTER, OR TRUNKING
MULTI-SOCKET OUTLET ASSEMBLY
CABLE TRAY, TROUGH TYPE
FEEDER BUS DUCT (BUS BAR TRUNKING)
ANGLED LADDER CABLE TRAY WITH HINGED SPLICE PLATES
OVERHEAD CONDUIT RACK
CONTROL STATION
ENCLOSED CONTACTOR, AMPERAGE INDICATED; "ON-LOAD" RATED
ENCLOSED STARTER, SIZE INDICATED; "ON-LOAD" RATED
JUNCTION BOX, SURFACE MOUNTED UNLESS OTHERWISE NOTED.
CB
F63
40
63
40
CONDUIT DOWN
SPACES AND EXPOSED ELSEWHERE UNLESS OTHERWISE INDICATED
CONDUIT AND CONDUCTORS OR CABLES BELOW GRADE OR SLAB
CONDUIT UP & DOWN
BRANCH CIRCUIT HOME RUN TO PANELBOARD
PLUG-IN DEVICE TYPE & RATING PER SPECS AND/OR ONE-LINE DIAGRAM
C
EM
G
GROUND ROD (EARTHING)
CONDUIT, STUBBED, AND CAPPED
C = CONTROL SYSTEM CONDUIT
EM = EMERGENCY POWER SYSTEM CONDUIT
EXOTHERMIC WELD
GROUND TEST WELL
CONDUIT UP
PLUG-IN BUS DUCT (BUS BAR TRUNKING)
ENCLOSED STARTER, COMBINATION, SIZE INDICATED; "ON-LOAD" RATED
CONDUIT AND CONDUCTORS OR CABLES CONCEALED IN FINISHED
2 -
IDENTIFIER
2T = TEMPORARY POWER
3 = FAB 38
2 = FAB 28
M = MSCP
Z = 480V TOOL DISTRIBUTION PANEL
FAB/CUB
1 = GROUND LEVEL
0 = UNDERGROUND
5 = OFFICES
4 = OFFICES
6 = ROOF
3 = GOWN
2 = SORT
MSB
T = 208V/120V TRANSFORMER
-AA12
B = BULK GAS YARD
W = WAREHOUSE
2 = SUBFAB
BARE COPPER 120sqmm GROUND CONDUCTOR 80cm BELOW GRADE
DC POSITIVE
DC NEGATIVE
SWITCHLEG (LTG)
RED
PHASE COLOR
BLACK
COLOR
BROWN W/BLACK LABEL
BROWN
BLUE
GREEN/YELLOW
BROWN W/ORANGE LABEL
CONDUCTOR
GROUND
NEUTRAL
PHASE T (C)
PHASE S (B)
PHASE R (A)
CONDUCTOR COLOR CODES
NEGATIVE SEQUENCE RELAY
LOSS OF FIELD RELAY
REVERSE POWER RELAY
UNDER/OVER VOLTAGE RELAY
WITH ADJUSTABLE TIMER
40
46N
32
30
27/59/T
ANNUNCIATOR
AND FREQUENCY MATCHING
SYNCHRONIZING CHECK RELAY
AUTOMATIC SYNCHRONIZER W/VOLTAGE
OVER TEMPERATURE
26
25
15/25A/60
NO.
FUNCTION
DEVICE
DESCRIPTION
INSTANTANEOUS AND TIME
TIME OVERCURRENT RELAY WITH
OVERCURRENT RELAY
VOLTAGE RESTRAINT
PHASE SEQUENCE VOLTAGE RELAY
EARTH FAULT RESIDUAL CURRENT RELAY
51V
49
51N
50/51
THERMAL RELAY
47
DIRECTIONAL OVERCURRENT RELAY
AC DIRECTIONAL OVERCURRENT RELAY
OVER/UNDERFREQUENCY RELAY
DIFFERENTIAL PROTECTIVE RELAY
VOLTAGE REGULATOR
TRIP LOCKOUT RELAY
ELECTRONIC GOVERNOR
UNDERFREQUENCY RELAY
OVERFREQUENCY RELAY
90P
86
90
87
VAR/PF CONTROL
81O
81U
81O/U
67N
67
65E
AC GROUND
OVERVOLTAGE RELAY
52
59
CIRCUIT BREAKER (M=MAIN, F=FEEDER)
FORCED FIELD EXCITATION REGULATOR
94
90F
TRIPPING RELAY
BUS DIFFERENTIAL RELAY
87B
UNDERVOLTAGE RELAY
27
IEEE DEVICE FUNCTION/LEGEND
COPPER GROUND PLATE (ALSO FOR EQUIPMENT GROUNDING)
COPPER PIGTAIL
TRAY NUMBER
E
SEGMENT NUMBER
7=D.B
6=MCC
5=LVSSCUB
8=P.B
9=V.S.D4=V.S.D
3=P.B
FAB 0=LVSS
1=MCC
2=D.B
V= VERTICAL
W = WAREHOUSE
B = BULK GAS YARD
M = MSCP
S = SITE/MAIN SUBSTATION
O = MSB
C = CUB
H = HAZARDOUS MATERIALS BUILDING
P = PROJECT BUILDING/WAREHOUSE
F = FAB
BUILDING
2 = SUBFAB
3 = CLEANROOM
4 = INTERSTITIAL/FAN-DECK
5 = UPPER FAN-DECK
6 = ROOF
0 = UNDERGROUND
1 = UTILITIES
MSB
2 = SORT
3 = GOWN
4 = OFFICES
5 = OFFICES
0 = UNDERGROUND
1 = GROUND LEVEL
(Bottom of tray)
U = UNARMORED CABLE
E.G.:
CABLE TRAY & TRUNKING ID SYSTEM
00101F1
CABLE TRAY
SIZE (mm)
ELEVATION (m)
N = NORTH
E = EAST
ROUTE
- -
WHEN MORE THAN (1) CABLE
TRAY TAG IS SHOWN AND
POINTED TO THE SAME TRAY,
IT INDICATES (2) OR MORE
STACKED TRAYS.
SEQUENTIAL NUMBER
XXX
ROUTE
1 0
CONDUIT & CABLE NUMBERING SYSTEM
P
EG.: [AP-10100-03]
A -03
TYPE
A = ARMORED CABLE
BLANK = CONDUIT
VOLTAGE
H = 22KV
S = 6.6KV
P = <600V
CIRCUIT/CUB #/00
LEVEL
D = <50V CONTROL CABLES
C = CONTROL
12=D.B
11=MCC
10=LVSSMSB
13=P.B
14=V.S.D
17=D.B
16=MCC
15=LVSSMLCP
18=P.B
19=V.S.D
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
TYPICAL LUMINAIRE ATTRIBUTES:
MOTION DETECTOR; SUBSCRIPT DENOTES: U=ULTRASONIC P=PASSIVE
INFRARED
S2
EXP 30
LIGHTING FIXTURES EXPLOSION PROOF
ON COLUMN OR NEARBY
FGB/GP
FOUNDATION COPPER GROUNDING BUS / GROUNDING PLATE
EGB
EQUIPOTENTIAL GROUNDING BUS
ETC ETCETERA
COPPERCU
L
P
S
HEAT TRACE END-OF-LINE INDICATING LIGHT
HEAT TRACE POWER CONNECTION BOX, HEATING
HEAT TRACE CABLE SPICE BOX
CABLE TO POWER HOMERUN
xx xxHEAT TRACE HEATING CABLE (PLAN DRAWING ONLY)
HEAT TRACE THERMOSTAT WITH
BULB AND CAPILLARY
HEAT TRACE RESISTANCE TEMPERATURE DEVICE
3W = 3 WATT (AS SHOWN)
CABLE WATTAGE INDICATED AS:
SELF REGULATING MEDIUM TEMP HEAT TRACE CABLE, 208V
5W = 5 WATT (AS SHOWN)
15W = 15 WATT
10W = 10 WATT
8W = 8 WATT
5W = 5 WATT
20W = 20 WATT
10W = 10 WATT
8W = 8 WATT
CABLE WATTAGE INDICATED AS:
SELF REGULATING LOW TEMP HEAT TRACE CABLE, 208V
3W = 3 WATT
HEAT TRACE LEGEND:
SWITCH CURRENT RATING INDICATED, 3 POLE UNLESS
OTHERWISE INDICATED
400
CIRCUIT BREAKER; THERMAL MAGNETIC OR SOLID STATE TRIP. 3 POLE
UNLESS OTHERWISE INDICATED, FIXED TYPE
FRAME RATING
BREAKER RATING
TRIP SETTING
FRAME RATING
BREAKER RATING
TRIP SETTING
630
400
400
OR
M
H = HEAT TRACE PANEL
2