Characteristic In case of applying external power type, as equipment which supplies DC power being used to get necessary type current after applying DC voltage between anode and type object, it is divided into a manual rectifier and automatic rectifier according to the method adjusting optimum protection potential.
Main Customer Korea Hydro and Nuclear Power Co., Ltd. Hyundai Heavy Industries- UAE BNPP Project State Company for Oil Projects - IONE Karblala Refinery Project
Product Specification Specification considering types of input voltage, phase voltage, output voltage, current and automatic current, selection of automatic type (analog or digital), and others (cooling type, electrical box and so on).
Certification ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007
Technology Specification Switching type: rectifier circuit RMCS type: remote control type OIL cooling & AIR cooling
Cathodes Protection Rectifier
Electricity
Medium Volt MCSG & Non-Segregated Phase
Characteristic Device which supplies each road with a high voltage power, cuts off overcurrent & fault current and protects internal device & system
Main Customer KHNP
Product Specification W950 x D2500 x H2460
Certification ISO 9001 ISO 14001 KEPIC-EN
Technology Specification AC 13.8KV 2000A 50KA AC 4.16KV 3000/2000/1200A 50KA
34
Characteristic As a device taking charge of controlling direct current motor & distributing direct current power, main circuit interrupter of Incoming and Feeder is composed of DC ACB.
Main Customer KHNP
Product Specification W700 x D1200 x H2350
Certification ISO 9001 ISO 14004 KEPIC-EN
Technology Specification DC 125/250V 1600/3000A 30/50KA
DC Motor Control Center
Characteristic Device which is manufactured for the purpose of switching, protecting motor or load resistance etc. and stores in enclosure, unit apparatus that switching device & supervisory control device etc. are arranged every unit circuit.
Main Customer KHNP ENEC
Product Specification W565 x D550 x H2350
Certification ISO 9001 ISO 14003 KEPIC-EN
Technology Specification AC 480V 600A 30KA/42KA AC 480V 600A 30KA/42KA
480V Motor Control Center
Korea Nuclear Partners
35
Characteristic A rectifier is a device to get DC by using a diode or SCR, IGBT rectifier element after collecting single or triple DC. It is used as an auxiliary power device for blackout or used when the stable DC is required. International Electric Co., Ltd. manufactures and supplies all sort of rectifiers with high reliability, and has achieved recognition of performance excellence already.
Main Customer Korea Hydro and Nuclear Power Co., Ltd. HUVIS WATER MHIEC
Product Specification 10 ~ 20000A
Certification ISO 9001, 14001 KEPIC INNO-BIZ
Technology Specification The details of specification and technical information can be provided separately.
RECTIFIER
Characteristic An inverter is a device to get single or triple AC by using IGBT as a converting element through colleting DC. It is used as an auxiliary power device for blackout or used when the stable DC is required. International Electric Co., Ltd. manufactures and supplies all sort of inverters with high reliability, and has achieved recognition of performance excellence already.
Main Customer Doosan Heavy Industry Hanjin Heavy Industry ENEC
Product Specification 5 ~ 400kVA
Certification ISO 9001, 14001 KEPIC INNO-BIZ
Technology Specification The details of specification and technical information can be provided separately.
INVERTER
Electricity
36
Characteristic As a distribution board being installed in power plant, it is a device taking charge of distributing power of DC/AC & lighting load.
Product Specification W1000 x D700 x H2500 W1000 x D350 x H1700 W1000 x D600 x H2300 W600 x D190~350 x H1100~1900
Certification ISO 9001 ISO 14005 KEPIC-EN
Technology Specification 120VAC/125VDC 100/400A 10KA 380/220VAC 225A 10KA 208/120VAC 100A 10KA
Main Customer KHNP
AC/DC Dist. Panel & Transfer Switch
Characteristic Dry type transformer installed at power equipment (UPS, B/C, rectifier and so on)Realization of eco-friendly product (high efficiency, miniaturization, weight lightening, low noise) Rubust, durable and long life expectance
Main Customer SK Energy ILSUNGACE/ SAUDI VARTEC/ KUWAIT
Product Specification Rated power : 15KVA Input / output voltage: 220 - 480AC / 216 - 540VAC Insulation class: F & H class Frequency: 50, 60Hz
Certification ISO 9001, 14001 KEPIC INNO-BIZ
Technology Specification The details of specification and technical information can be provided separately.
Dry Type Transformer
Korea Nuclear Partners
37
Characteristic As an emergency diesel generator excitation system which is a safety grade of nuclear power plant, it applied digital triple controller in consideration of importance and rectifier is composed of dualization.
Main Customer KHNP
Product Specification Digital TMR triple controller three phase radio wave Thyristor phase controlling rectifier Dualization of rectifier (N+1 Redundancy)
Certification ISO 9001:2009 ISO 14001:2009 K-OSHMS 18001
Technology Specification A function block type of program following IEC 61131-3 is used. It satisfies a quick response excitation system of IEEE 421
Emergency diesel generator excitation system of nuclear power plant
Characteristic Emergency diesel generator excitation system inspection & testing device carries out each card testing composing excitation system, and it can not only test the integrity of each card but also test various controls and protection functions etc. of excitation system by injecting simulation signal corresponding to generator signal at the situation of separating excitation system from generator. Particularly, as it can test the function of excitation system for a short time without driving diesel engine, it can test easily even when problem occurs or at normal times.
Main Customer Korea Hydro and Nuclear Power Co., Ltd.
Certification KEPIC-EN KS Q ISO 9001:2011 CE certificate (Digital Excitation Control System)
Technology Specification Test function of each card of excitation controller. Excitation linked test function
- Checking test of power supply of controller- EDG start and stop test- Operation range checking test- Mode switchover test- Step response test- Under excitation limit test Total test function Save function of test history data by card
Emergency diesel generator excitation system inspecting & testing device (ETS-5000)
Electricity
38
Characteristic Device which supplies each load with a low voltage power transformed from transformer, cuts off overcurrent & fault current and protects internal device & system.
Main Customer KHNP
Product Specification W700 x D2066 x H2450
Certification ISO 9001 ISO 14002 KEPIC-EN
Technology Specification AC 480V 1600/2000/3000A 30/50KA
480V Load Center
Characteristic 3-phase voltage, current signal corresponding to generator power is generated to enable comprehensive performance test of excitation system at the situation of not operating a generator and enables simulation driving at the same condition as the linked condition of actual generator and power system.
Certification KEPIC-EN KS Q ISO 9001:2009 CE certificate (Digital Excitation Control System)
Technology Specification Diagnosis and adjustment of excitation system Adjusting function of output of mock signal AVR, MVR operation test Step Response test of excitation system V/Hz limit test loss of field test PSS test Under excitation limit test
Main Customer Korea Hydro and Nuclear Power Co., Ltd. Korea Electric UAE Nigeria
Generator excitation system simulation diagnosis equipment(RTS-7000)
Korea Nuclear Partners
39
Characteristic Controller for nuclear power plant with safety gradeSuccess of localization of controller by achieving licensing from Council for Nuclear Safety and securing Q grade for nuclear power plantKEPIC-EN certification (1st grade logic unit for nuclear power plant)Provision of 22 kinds of module as well as a process module.
Main Customer KHNP
Product Specification 19”standard, W*H*D = 482.6 x 281.35 x 294mm Supplying 22 modules such as process module, communication module, digital/analog input-output module, special module and so on.
Supplying Software Engineering Tool
Certification KEPIC ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007
Technology Specification Design satisfying the regulations and specifications for nuclear power plant (IEEE 603, IEEE 7-4.3.2, etc.)
Securing the quality of Class 1E H/W and Safety-Critical S/W Provision of functions of maintenance and diverse on-line self-diagnosis.
Safety grade PLC POSAFE-Q Electrical Panel
Characteristic Vitzrotech high pressure distributing board is developed by our own technology with introduced advanced technology over years. It is an optimized system for collection and distribution of current and power facilities such as power producing and converting utilities, all sort of plants, general industrial facility, building and public facility, securing high reliability and stability of power supply. Vitzrotech low pressure distributing board is a low pressure less than 600V distributing facility and is designed to be compact having withdrawing type of air circuit breaker with high capacity and auxiliary devices. It minimizes the installation spaces and shows high performance and high reliability fit to customer's request by considering system coordination. It is designed to be proper to specification requirements and regulation of all sort of plant, nuclear power plant, hydraulic power plant and thermoelectric power plant.
Main Customer KHNP
Product Specification 508V 50kA 508V 30kA
Certification KEPIC qualification certificate ISO 9001 ISO 14001
Technology Specification KEPIC EEE 2000(2000)
Electricity
40
Product Specification Capacity: 10kVA, 30kVA, 50kVA Overload: 125% 60min, 150% 1min Input: 3Pahse 3Wire 480Vac ± 10%, 50Hz/60Hz Output: 1Phase 2Wire 120Vac ± 2% Battery Connection: 120Vdc
Characteristic Equipment supplying the power to important parts of plant by uninterruption in blackout.
Main Customer SPG chemical Midland Power
Certification ISO 9001 UPS direct production certificate DIM V3 CE and KC
Technology Specification SCR Phase shift Rectifier (6pulse, 12pulse select) SCR Charger (50kVA model Only) IGBT SPWM Inverter
UPS (Uninterruptible Power Supply)
Characteristic N+1 parallel operation Online double Conversion DSP control Input THDi : <3% Voltage selection of storage battery 16/18/20PCS Load power factor 0.9PF Allowable range of input voltage 120~276Vac Allowable range of input frequency 54~66Hz ECO mode for energy saving UPS start by self-diagnosis All sort of interface (SNMP, Relay Card, parallel card)
Main Customer Korea Hydro and Nuclear Power Co., Ltd. Korea Midland Power Co., Ltd. DAEWOO JODAN KEPCO UAE
Product Specification 5 ~ 200kVA
Certification ISO 9001, 14001 KEPIC INNO-BIZ
Technology Specification The details of specification and technical information can be provided separately.
UPS
Korea Nuclear Partners
41
Characteristic This is a device getting DC with a diode or SCR, IGBT rectifier element by collecting single or triple phase AC. It is applied more to special power equipment and safety power equipment by industrial facilities' precision and automation.
Main Customer Korea Hydro and Nuclear Power Co., Ltd. DAEWOO JODAN KEPCO UAE
Product Specification 10 ~ 2000A
Certification ISO 9001, 14001 KEPIC INNO-BIZ
Technology Specification The details of specification and technical information can be provided separately.
Battery Charger
Characteristic Vitzrotech has improved blocking performance and safety with the optimized vacuum technology and structure design from integration of accumulated vacuum application technology for long time through development and production of vacuum interrupter at first in Korea. And also we maximized insulation performance by solid insulating and a batch of barrier through safer and stabler device and vacuum interrupter molding from a user-centric design. Our product is a new concept of breaker to safely supply the power to all industry areas such as power plants, chemical plants, steel plants and construction facilities and to pursue the short arc time and interrupting time and no repair against short circuit and earth fault.
Main Customer KHNP
Product Specification 4.76kV 50kA 15kV 40kA
Certification KEPIC qualification certificate ISO 9001 ISO 14001
Technology Specification KEPIC EED 1100(2005) IEEE Std C37.09(1999) IEEE Std C37.09a(2005) Verification of equipment (EQ/earthquake-proof, environment-resistance)
Vacuum Circuit Breakers
Electricity
42
Air Circuit Breakers
Characteristic Vizrotech air circuit breaker is approved by IEC new standard and KS standard development test. It is a premium product that provides convenience of short breaking time and reduction of working time in installing newly and more and that provides convenience of use by securing user's safety and protection with maximum.
Main Customer KHNP
Product Specification 508V 65kA 508V 50kA 508V 30kA
Certification KEPIC qualification certificate ISO 9001 ISO 14001
Technology Specification ANSI C37.13(1990)
Product Specification
Characteristic High Pressure Feeder, Motor, Triple Protective Relay for protecting transformer
Main Customer South East Power Midland Power
Certification ISO 9001 UPS direct production certificate DIM V2 CE and KC
Technology Specification 2 out of 3, 1 out of 2 Voting and single trip mechanism
TRIUMP
Korea Nuclear Partners
43
Characteristic While an illumination lighting used in a general industrial area, residence area and commercial area has replaced from the existing lighting source such as fluorescent lighting to LED, a general LED lighting was impossible to apply to a nuclear power plant, especially a radiation place due to its leakage of gamma rays. Therefore Solux has developed an original technology about LED packages that work even under circumstances exposed to the gamma rays without any problem and LED lightings that remove prohibition materials on use by each section.
Main Customer KHNP UAE OSSA
Product Specification The LED products are finished to develop according to the standard velocity of light of existing light source such as 35W and 50W which the nuclear power plant has used.
Certification IISO 9001:2009/ ISO 9001:2008 ISO 14001:2009/ ISO 14001:2004 UL Certificate (LIGHT-EMITTING-DIODE RECESSED LUMINAIRES)
Technology Specification A radiator, a core technology of general LED lighting, is normally manufactured with aluminum, which is a prohibited material on use in a radiation area (especially high radiation). And also this general LED package occurs defects such as no lighting even when it is exposed to a small gamma ray. Therefore Solux has developed and applied an LED package which removes the prohibited material on use and can endure the gamma ray.
LED lighting for nuclear power plant
Characteristic As an emergency lighting apparatus of nuclear power plant, it is always put out when applying voltage, as it has an automatic charging circuit, it is automatically converted to emergency power(Battery) to turn on the light for 8 hours.
Main Customer KHNP ENEC
Product Specification 220V, 230V18W x 2 Sealed Beam(PAR36)
Certification IECEE CB TEST ATEX IECEX SCHEME CE
Technology Specification Battery : 8hr Min. Weight : 19.4
EMERGENCY LIGHTING
Electricity
44
Simulation testing device for testing inverter control performance(ITS-5000)
Characteristic Simulation testing device for verifying inverter control performance is a testing device for verifying performance about main functions of inverter system. It is a device that can detect accident wave and card causing failure through main signal monitoring, analysis of inverter main functions and, check inverter system & individual card and record control performance..
Main Customer Korea Hydro and Nuclear Power Co., Ltd.
Certification KEPIC-EN KS Q ISO 9001:2010 CE certificate (Digital Excitation Control System)
Technology Specification Inverter output power mock (Over, Under Voltage) Alternative power mock To get and analyze the output of inverter and wave of alternative power in switchover test of inverter
Checking with details about main functions by card of inverter system To measure the quality of output power of inverter when changing loads by overload device.
Self-diagnosis function of tester of inverter control performance
Characteristic It is most important to secure safety for nuclear power plant cable against an accident of nuclear power plant and to this end, heat resistance and radiation resistance etc. are required. Especially, Class 1E cable being pulled in the reactor has to be completed for environmental qualification in accordance with IEEE 323, 383 and, TMC's cable for nuclear power plant was completed for design life of over 60 years and environmental qualification.
Product Specification Class 1E, Non-Class 1E 600V~15KV POWER 600V CONTROL, INSTREMENTATION CABLE
Certification ISO 9001 ISO 14001 OHSAS 18001 KEPIC
Technology Specification Heat-resisting property, radioactivity resistance, environment resistant property, smoke resistance according to design with more than 60 years life
Power/control/instrumentation cable for nuclear power plant
Korea Nuclear Partners
45
Characteristic 1. Emergency Generator Control Panel for Nuclear Power Plant
(EDG)2. Diesel Generator Control Panel of Alternating Current for Nuclear
Power Plant (AAC DG)3. Simulator Control Panel4. Safety and non-safety electrical box for nuclear power plant
(Q-CLASS)5. MCR CONSOLE (Q-CLASS) for nuclear power plant6. HVAC CONTROL PANEL for nuclear power plant
Main Customer Doosan Engine Doosan Heavy Industry Invensys Korea Hyundai Heavy Industry Korea Hydro and Nuclear Power Co., Ltd. Ponewtec
Product Specification EDG : 4160V 7200kW~8200kW AACDG : 4160V 7200kW~8200kW
Certification ISO 9001/14001 KEPIC-EN KS: cable tray
Characteristic Inflow of heat(high temperature), humidity and foreign material become the cause of failure & malfunction in the most electric/electronic devices. Particularly, digital device exposed to high temperature environment sharply shortens its lifespan due to aging of the parts and the facilities caused by this stops frequently. Thermoelectric cooling system is a product that can secure reliability of facilities by blocking and preventing the cause of main failure and malfunction of digital devices related to various control, electric, telecommunication positioned at the high temperature area of turbine, boiler vicinity of domestic and foreign power plant.
Main Customer Korea South-East Power Co., Ltd. Korea South Power Co., Ltd. Korea West Power Co., Ltd. Korea Midland Power Co., Ltd. Korea East-West Power Co., Ltd. Kuwait Doha-west Power Plant Thailand Navanakorn Power Plant
Technology Specification It has wide operating range with 5℃~60℃ and enables to operate under diverse environmental conditions. Its dehumidification function makes the temperature and humidity to be maintained even in a site with high humidity and to main panel of electronic equipment room. It can solve the problems that the existing thermo-hygrostat and conditioning equipment could not solved because it can remove condensation liquid water without a separate drain. It can install to sensitive equipment because it does not have a mechanical diving such as compressor. It can operate only with power without an outdoor unit and drain.
Thermoelectric Air Conditioner CNL-200TEC / CNL-800TEC
Emergency Generator Control Panel for Nuclear Power Plant & Simulator Control Panel & Q-CL electrical box & MCR CONSOLE & HVAC CONTROL PANEL
Electricity
46
Characteristic Partially installed sensors to detect any abnormality in the GIS equipment of power plants and substations discharge detection sensitivity of the device, a device for checking the performance and not damaged. The power generation system and the type of synchronization signal simulated partial discharge (corona, Boyd, floating, party table) through the facilities of a data analysis equipment to support efficient management of partial discharge diagnostic system.
1. Create a simulated partial discharge signal (broadband 0.5-1.5GHZ)2. Power Grid (PT) generated in synchronization with each type of
simulated partial discharge signals - Extracting a synchronization signal from the power substation - Create partial discharge type of simulated partial discharge
signals3. The partial discharge test and confirm trends recorded (effective
for risk management) - Record Management Checklist for the maintenance of such
examination, ensure the normal operation4. Provide a variety of communication services - Provides RS-232, Ethernet Port for connection of various systems
and - It is also associated with other equipment to facilitate the
implementation of standard protocols5. Provide user-friendly UI
Main Customer KEPCO
Product Specification Band: 500 ~ l, 5 (X) [MHz] Output signal range: -10 ~ -40 [dBm] (using a fixed attenuator: -40 ~ -70 [dBn])
Power: DC12V / 3.5A Battery: 11.1 [V], 10,400 [mAh] Synchronization signal (PT): AC220V Communication RS-232: 2 Port Communication Ethernet: 10 / 100BASE-TX: lPort Number of Channels: 3 channel, N-Type Connector LCD: 7 "TFT-LCD, Touch Screen Size: 242 (W) X 282 (H) X 64 (D) [mm] Weight: 3.7 [kg] Library: Simulated partial discharge, Magnitude, Pattern and Image
Certification Quality Management System Certification, Environmental Management System Certification
Technology Specification Provide detailed analysis functions with easy operation and equipment simulator PC with Graphic LCD
Simple portable structure (moving in a narrow space/Easy to use, Built-in battery which is rechargeable) The implementation of simulated partial discharge signal synchronization channel (3-channel simultaneous output signals)
GIS partial discharge detection device of diagnostic equipment
Korea Nuclear Partners
47
GIS partial discharge diagnostic system
Characteristic Real-time, online monitoring system for diagnosis of GIS partial discharge phenomena. This system is consist of collecting the partial discharge signal detection ,data monitoring device for acquiring data from the sensor installed in the GIS, analyzing the partial discharge signal, diagnostic server and the communication equipment.
Main Customer KEPCO
Product Specification Signal Measurement Range: 500-150 MHz] Signal Detection range: at least -85 [dBm], partial discharge detection of less than 5pC
Power supply: AC220V Communication RS-232: 2 port Communication Ethernet:10/100BASE-TX:1port,10/100BASE-FX:2ports
Input signal channel 3-channel / 6-channel Type (PT): Phase-locked power LED: power, communications, LED display channel LCD: 4.3 ", Graphic LCD Other: Watchdog and self-diagnostic function, RTC
Certification Quality Management System Certification, Environmental Management System Certification
Technology Specification LU (Local Unit)
- Remote Firmware Update- Time synchronization and traceability MU (Main Unit)
- Frequency spectrum analysis capabilities- Make a diagnosis about the type through the neural network
learning program- Web Service and SMS (Short Message Service)
Characteristic Mg-Anode: galvanic anode-type anode being used for steel structure in underground or underwater. As it has a high driving potential, it is suitable for environment of a high specific resistivity, its shape and weight can be applied variously depending on design.
Main Customer Daesung Energy Co., Ltd. Samchully Co., Ltd. SABIC - SAMAC MMA-PMMA PROJECT Kuwait National Petroleum Company - KNPC Clean Fuels
Project GS
Product Specification 3D3, 5D3, 9D2, 9D3, 14D2, 17D2, 17D3, 32D3, 32D5, 40D3, 48D5.
Certification ISO 9001 :2008 ISO 14001:2004 OHSAS 18001:2008
Technology Specification High potential, high efficiency No need of potential apparatus
MG-Anode
Electricity
48
Characteristic It is light and amount of generating current per unit weight is a lot, able to manufacture anode in large size, being the most widely used in offshore construction.
Main Customer Korea Western Power Co., Ltd. Korea Midland Power Co., ltd. Wafra Joint Operations - MGC Revamp PJT KOGAS AKKAS - AKKAS CPF PJT
Product Specification 145 * 125* 400 and others 30*100*200 and others (215+190)*210*300 and others (245+205)*235*720 and others (280+245)260*950 and others
Certification ISO 9001 :2008 ISO 14001:2004 OHSAS 18001:2009
Technology Specification High capacity is possible. No need of power device.
Aluminum Anode
Characteristic Material : Oxygen Free Copper Insulation Housing - PVDF, Kynar Surface : Electro-Tin Classified as Class 1E in accordance with IEEE 323 Metal insulation grip sleeve crimps to wire insulation, providing protection to the crimp joint during high vibration applications Insulation Temperature Rated at 150℃
Main Customer KHNP ENEC
Product Specification Material : Copper C 1020 Insulation : PVDF(Kynar460) Surface : Tin Plate Wire Range : AWG #22~#2 Temperature Rating : 150℃
Voltage Rating : 600V
Certification KEPIC-EN(EN-434) ISO 9001 UL,IEC,DNV,ABS,GL
Technology Specification CP-E2, IEEE 323, IEEE 344, AS 7928A, UL486-486B
Terminal Lugs (Class-1E, Non Class-1E)
Korea Nuclear Partners
49
Characteristic In case of applying cathode protection by anodes with rectifier to type object installed in fresh water or in soil, it is the most widely used anode of which effectiveness can be maximized by backfilling and using as Coke Breeze.
Main Customer Korea Hydro and Nuclear Power Co., Ltd. AL-DUR Power and Water Company - CONDENSER CP SYSTEM IN AL DUR PJT(BAHRAIN) Abu Dhabi Company of On shore Operations - BAB GAS COMPRESSTION PROJECT
Product Specification 1 1/2*60L and others
Certification ISO 9001 :2008 ISO 14001:2004 OHSAS 18001:2011
Technology Specification Small consumption rate. Need of power device.
H.S.C.I Anode
Characteristic It has a highest efficiency of galvanic anodes, as the strength of material is weak and arc is not generated in shock, it is suitable to use in area that flammable gas is not generated.
Main Customer Korea Hydro and Nuclear Power Co., Ltd. TAKREER - RUWAIS REFINERY EXPANSION PROJECT(PKG #3) SABIC - SAUDI KAYAN PC PROJECT
Product Specification 20*100*200 and others
Certification ISO 9001 :2008 ISO 14001:2004 OHSAS 18001:2010
Technology Specification High efficiency No need of power device.
Zinc Anode
Electricity
50
ElectricityKorea Nuclear Partners
Characteristic Various anodes such as Pb-Ag, Mixed Metal Oxide Ti, Pt-Ti, Pt-Nb etc. are used in cathode protection by anodes with rectifier. This anode has low consumption rate and high output current.
Main Customer Korea South-East Power Co., Ltd. Kuwait National Petroleum Company - KNPC FCC,SWT,C/T for CFP at Refinery PJT TAKREER - CBDC Project
Product Specification 70Φ×150L and others
Certification ISO 9001 :2008 ISO 14001:2004 OHSAS 18001:2012
Technology Specification Small consumption rate and long life. Made-to-order and diverse products.
Pb-Ag, Pt-Ti, MMO-Ti Anode