elgin outcrop - mcewen school of architecture · 2021. 3. 7. · vrf - hvac system variable...
TRANSCRIPT
![Page 1: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/1.jpg)
D O W N T O W N S U D B U R Y L I V E - W O R K - PA R K TYLER MACDONALD+LORNE MACEACHERNE L G I N O U TC R O P
![Page 2: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/2.jpg)
TENURE TYPES HOUSEHOLD INCOME PROGRAM ADJACENCIES
2 SITE ANALYSIS
![Page 3: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/3.jpg)
URBANdesign
![Page 4: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/4.jpg)
SITE
4 SITE STRATEGIES
![Page 5: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/5.jpg)
AXIS + ADJACENCIES
SITE STRATEGIES5
![Page 6: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/6.jpg)
ACCESS
SITE STRATEGIES6
![Page 7: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/7.jpg)
LIGHTWELLS
SITE STRATEGIES7
![Page 8: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/8.jpg)
GREEN SPACE
SITE STRATEGIES8
![Page 9: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/9.jpg)
PRIVATE + PUBLIC SPACE
SITE STRATEGIES9
![Page 10: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/10.jpg)
Typical 16-BD Residential Block
LEGEND
Commercial Suite
Farmer’s Market
4-Story Office Building + Cafe
Light-Well Pedestrian Parking Ramp
10 PROGRAM AXONOMETRIC
![Page 11: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/11.jpg)
Light-Well Pedestrian Parking Ramp
Legend:
Urban Plazas
Alleyway Bistro
Elgin Greenway Sideyards
1
1
1
12
2
2
2
3
3
4
4
4
4
11 DETAILED AXONOMETRIC
![Page 12: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/12.jpg)
SITE PLAN
URBAN-ALIGNED PAVERSBISTRO ALLEY PERIMETER BIOSWALES
12 SITE DESIGN
![Page 13: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/13.jpg)
13 STATION LIGHTWELL
![Page 14: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/14.jpg)
GROUND FLOOR PLAN
PARKING PLAN
14 SITE PLANS
![Page 15: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/15.jpg)
GROUND FLOOR PLAN
PARKING STRUCTURAL PLAN
15 SITE PLANS
![Page 16: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/16.jpg)
16 STATION LIGHTWELL
![Page 17: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/17.jpg)
Office Precedents:Dome Office, Bruther Architects (Right)Wood Innovation Centre, Michael Green (Below)
Housing Precedents:Local Apartment Typology (Above)Local Natural Stone Facades (Above,Right)Alpin Sport Ski Offices, Bernardo Bader (Right)Fisher House, Louis Kahn (Far Right)
Market Precedents:Pike Place, Miller Hull (Left)Smithson Upper Lawn Pavilion, Peter + Allison Smithson (Below)
17 DESIGN PRECEDENTS
![Page 18: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/18.jpg)
HOUSINGdesign
![Page 19: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/19.jpg)
19 HOUSING NORTH ELEVATION
![Page 20: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/20.jpg)
LobbyLobbyCommercial
Sideyard
Bistro
Garden
Mech.
Laundry
Mach.
Stair1
Stair2
20 NORTH HOUSING CONTEXT PLAN
![Page 21: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/21.jpg)
Office
Mech
Mech
WinterGarden
Winter Garden
Stair1
Corridor
Stair2
1st FLOOR LOFT UNIT + 2-BD FLAT
21 HOUSING 2nd + 4th FLOOR PLAN
![Page 22: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/22.jpg)
Stair1
Corridor
Stair2
Mech
Winter Garden
WinterGarden
Master
Patio
2nd FLOOR LOFT UNIT + 2-BD FLAT (5TH FLOOR SHARED ROOF TOP)
22 HOUSING 3rd + 5th FLOOR PLAN
![Page 23: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/23.jpg)
WinterGarden
WinterGarden
Bathroom
Bathroom
Ensuite
Ensuite
Mech
Mech
23 HOUSING SECTION
![Page 24: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/24.jpg)
LOFT UNIT 2-BD FLAT
BUILDING
CLT Walls + DLT Floors
Mass Timber Beams + Columns
24 HOUSING STRUCTURAL AXO
![Page 25: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/25.jpg)
25 LOFT UNIT VIEW
![Page 26: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/26.jpg)
OFFICEdesign
![Page 27: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/27.jpg)
27 OFFICE NORTH ELEVATION
![Page 28: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/28.jpg)
Cafe Grey St Plaza
Lobby
Recep.
Atrium + Lightwell
28 OFFICE CONTEXT PLAN
![Page 29: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/29.jpg)
Lunch
Production
Collaboration
Privacy
Public + Meeting
29 TYPICAL OPEN OFFICE LAYOUT
![Page 30: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/30.jpg)
Small MeetingCollaboration
Cafe Lobby
Atrium+Lightwell
PublicProduction
30 OFFICE SECTION
![Page 31: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/31.jpg)
CLT Perlins
CLT Walls + DLT Floors
Mass Timber Beams + Columns
31 OFFICE STRUCTURAL AXO
1
3
4
Penthouse
2
![Page 32: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/32.jpg)
32 OPEN OFFICE VIEW
![Page 33: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/33.jpg)
MARKETdesign
![Page 34: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/34.jpg)
34 MARKET NORTH ELEVATION
![Page 35: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/35.jpg)
35 MARKET CONTEXT PLAN
Receiving
Large Market Stalls
Small Market Stalls
![Page 36: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/36.jpg)
Administration
Event Space
Mechanical
36 MARKET 2nd FLOOR PLAN
![Page 37: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/37.jpg)
37 MARKET SECTION
![Page 38: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/38.jpg)
38 MARKET INT. VIEW
![Page 39: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/39.jpg)
HOUSINGsystems
![Page 40: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/40.jpg)
PARTIAL NORTH ELEVATION DETAILED SECTION
Exterior Wall Assembly- Tapered natural stone rainscreen- 19mm air space- 50mm rigid insulation- Weather barrier - CLT Structure - 2x4 wood stud wall w/ batt insulation- 13mm interior finish
Roof Assembly- Waterproofing membrane - 2x100mm rigid insulation- Weather barrier- DLT Structure - Ceiling furing + finish as required
Typical Floor Assembly- 19mm finish floor- 19mm wood strapping- Acoustic underlayment- DLT Floor Structure - Ceiling furing + finish as required
40 HOUSING CONSTRUCTION
![Page 41: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/41.jpg)
Metal cap flashingMasonry tie
Continuous rigid insulationContinuous weather barrier
Weather barrier lapped over metal flashingMasonry angle suppor
LVL curtain wall lintel
Sealant all around opening w/backer rod + insulation
41 PARAPET DETAIL
![Page 42: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/42.jpg)
Metal flashingSteel angle curtain wall support
Continuous Rigid InsulationWeather barrier lapped over metal flashingMasonry angle supportTapered natural stone rainscreenSealant all around opening w/backer rod + insulation
42 B.O. + T.O. CURTAIN WALL
![Page 43: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/43.jpg)
Weather barrier lapped over metal flashing
Masonry angle supportReinforced concrete perimeter beam
Perimeter drainageStructural fill
Parking Structure
43 B.O. EXTERIOR WALL
![Page 44: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/44.jpg)
Exterior Wall Assembly13mm interior finish2x4 wood stud wall w/ batt insulationCLT StructureWeather barrier50mm rigid insulation19mm air spaceTapered natural stone rainscreen
Glo Ball Fixtures, Jasper MorrisonVarying sizes + mounting
1st Floor Loft - Ceiling + Pendant2nd Floor Loft - Wall Sconce + Pendants
Task lighting in Kitchen, Office + Mechanical Closet.
VRF - HVAC SystemVariable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control.
ERV Exhaust
VRF Heating + Cooling
ERV Supply
44 LOFT UNIT AXO
![Page 45: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/45.jpg)
45 VRF SYSTEM
![Page 46: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/46.jpg)
1st Floor Lighting 2nd Floor Lighting
46 LOFT UNIT LIGHTING PLANS
![Page 47: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/47.jpg)
47 LOFT UNIT DAYLIGHTING
![Page 48: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/48.jpg)
WINTER GARDEN + THERMAL MASS- Contain summer solar gain - Vertical shading on inside wall of winter garden.- 2nd floor of winter garden acts as ‘overhang.’- Thermal mass bench transfer heat inside unit at night.
48 LOFT UNIT - SUMMER PASSIVE
![Page 49: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/49.jpg)
WINTER GARDEN VENTILATION- Ventilate Winder Garden for summer use. - Tilt+Turn windows on 1st + 2nd Floor- Stack effect is used to cool down space using prevailing summer winds
49 LOFT UNIT - SUMMER PASSIVE
![Page 50: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/50.jpg)
CROSS VENTILATION- Naturally Ventilate Loft Unit as required.- Large operable windows are provided in nearly everyroom to maxi-mizes passive cooling.
50 LOFT UNIT - SUMMER PASSIVE
![Page 51: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/51.jpg)
WINTER GARDEN + THERMAL MASS- Capture solar gain in the winter garden.- Passively heat through slow release of thermal mass.- Open Winter garden interior windows to allow for rapid passive heating.
51 LOFT UNIT - WINTER PASSIVE + ACTIVE
![Page 52: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/52.jpg)
2ND FLOOR SERVICE PLENUM - Duct work for VRF-HVAC system + ERV ducts to run in dropped ceiling be-low the 2nd floor plate. - Forced air is released into spaces along windows where applicable.
52 LOFT UNIT - WINTER ACTIVE
![Page 53: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/53.jpg)
OFFICEsystems
![Page 54: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/54.jpg)
TYPICAL OFFICE WALL SECTION - LIGHTINGTYPICAL OFFICE REFLECTIVE CEILING PLAN
54 OFFICE SYSTEM INTEGRATION
![Page 55: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/55.jpg)
HVAC SUPPLY
PENTHOUSE HVAC UNIT
HVAC RETURN
DROPPED GYPSUM CEILING
Penthouse
TYPICAL OFFICE PLAN
55 OFFICE - HVAC AXO
![Page 56: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/56.jpg)
56 OFFICE DAYLIGHTING
![Page 57: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/57.jpg)
ATRIUM HEAT GAIN- Contain summer solar gain -Sliding vertical shutters on glazed south facade for optional shading. - Public Atrium separate from longer occupancy spaces
57 OFFICE - SUMMER PASSIVE
![Page 58: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/58.jpg)
ATRIUM VENTILATION- Contain summer solar gain -Mechanical louvres located high along atrium south facade to remove excess heat in summer months.
58 OFFICE - SUMMER PASSIVE
![Page 59: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/59.jpg)
ATRIUM HEAT RECOVERY - Collect atrium solar gain during winter months.-Return air duct located in dropped ceiling of the atrium public lobby.
59 OFFICE - WINTER PASSIVE + ACTIVE
![Page 60: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/60.jpg)
PASSIVE HEATING - Adjacent north facing open office to be heatedthrough atrium heat recovery. - Ducts run parallel to beams;minimizing interference.
60 OFFICE - WINTER PASSIVE + ACTIVE
![Page 61: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/61.jpg)
MARKETsystems
![Page 62: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/62.jpg)
SHADING + THERMAL MASS- Contain summer solar gain - Vertical shading on entire Market clear story to minimize solar gain in summer months. - Exposed thermal mass concrete slab retains heat and is releasedintot the space as the day cools.
62 MARKET - SUMMER PASSIVE
![Page 63: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/63.jpg)
CROSS VENTILATION- Naturally Ventilate Market space as required.- Large operable windows are provided on south and north facades.
63 MARKET - SUMMER PASSIVE
![Page 64: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/64.jpg)
HEAT RECOVERY - Collect double height market space solar gain during winter months.-Return air ducts located between perlin beams spanningbetween large trusses.
64 MARKET - WINTER PASSIVE + ACTIVE
![Page 65: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/65.jpg)
PASSIVE HEATING - Heat from double height market space reused throughout Market spaces. - Exposed ducts hang from wood trusses, to mechanical space on south west corner.
65 MARKET - WINTER PASSIVE + ACTIVE
![Page 66: ELGIN OUTCROP - McEwen School of Architecture · 2021. 3. 7. · VRF - HVAC System Variable Refrigerant Flow Heating + Cooling System. 2-Zones - North + South for greater user control](https://reader035.vdocuments.net/reader035/viewer/2022071605/614105ba83382e045471d1bf/html5/thumbnails/66.jpg)
Thank you!