emergency brochure final lr 20-10-10

64
Emergency

Upload: con-gio

Post on 21-Jan-2016

164 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Emergency Brochure Final LR 20-10-10

Emergency

Page 2: Emergency Brochure Final LR 20-10-10

Emergency

DOT 1250 / E

13

Nipper / E

14

High 5® / E

16

Regency Bare

18

Regency Diffused

19

Deluxe Bare Batten

20

Deluxe Diffused

21

Unilux

22

LED Exit

2

Director

4

Director LED

6

Stingray

7

Stingray LED

8

Futcha 5 LED

9

LED Firefly

10

Firefly®

12

Page 3: Emergency Brochure Final LR 20-10-10

Emergency

ET Troffer

23

TR322

24

Condo

26

Hades I - LED / E

27

Guardian GR99

28

Guardian GR21

29

Weatherlux®

30

Warden LED

31

Vandal X IP65

32

Extreme

33

EXDN IP66

34

Condo WP

35

PWP™ & PWA™

36

SDW / SDWA

37

SDIP

38

Vandaguard®

39

Vandalux®

42

NXS

44

Maxi Pac IP65®

46

Metro Emergency

47

DIGINET

48

DIGINETDALI Emergency

Control Panel

49

DIGINETCable

ManagementOptions

50

Technical

51

Page 4: Emergency Brochure Final LR 20-10-10

Technical

2 Emergencymax dim(mm)

Product Codes

Code Version

Stylish, energy efficient LED exit luminaire compliant to Australian emergency lighting standards AS/NZS2293.

LED Exit

Features• 50,000 hour strip LED lamps• Polycarbonate housing • Slimline acrylic legend blade• Fully approved to AS/NZS2293 thermal

& illuminance requirements• Pictogram viewing distance is 24m• Surface & Recessed mount, Swivel action of panel for use

on angled ceilings• Low power consumption• A complete ‘one box’ solution including body diffuser and

LEDXM2P LED Exit with Pictogram Inserts

LEDXM2PB LED Exit with Black body and Green/ Black Theatre Pictogram

Accessories

LEDRB Recessed Bracket (cut-out: 380x88mm)

EXCB Cantilever bracket

LEDCM Conduit mount box

SKITLED Suspension Kit

99023330 Rod suspension white

99023360 Rod suspension black

DIRPPSS Pictogram inserts single sided

DIRPPDS Pictogram inserts Double sided

Spare Parts:

BP2SSC 2.4V NiCad, 2Cell

IP20

2.0kg 368 x 55 x 255

all pictogram inserts• Optional black ‘theatre’ body housing and picto inserts• Optional DALI monitored systems available

ApplicationsIdeal for emergency lighting application where aesthetics are everything, commercial office areas,hotels, shopping and cinema complexes, apartments, hospitals.

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6

LEDXM2P C0 D1.25 4 3.8 3.4 2.9 2C90 D1.25 4 3.8 3.4 2.9 2

All pictogram inserts

Page 5: Emergency Brochure Final LR 20-10-10

LED Swivel Action - Wall or Ceiling Mount

Conduit Mount BoxLEDCM

Cantilever BracketEXCB

3Emergency

Page 6: Emergency Brochure Final LR 20-10-10

Technical

4 Emergencymax dim(mm)

Traditional style exit luminaire complete with diffuser and pictogram legend compliant to AS/NZS2293.

Director

Features• Energy efficient lamp 10 watt fluorescent• Quick connect removable gear tray• Surface mount wall / ceiling• Injection moulded ABS housing and acrylic diffuser

with pictogram legend• Maintained, non-maintained and sustained available• Viewing distance 24m• Optional opal diffuser

IP20

2kg 380 x 160 x 220

• A complete ‘One Box’ solution including body, diffuser and all pictogram inserts

• Compliant to AS/NZS2293

ApplicationsGeneral purpose interior exit luminaire, commercial buildings, shops and interior carparks.

Product Codes

Code Version

Body less diffuser

DIR10M 10W Maintained

DIR10NM 10W Non-Maintained

DIR10S 2x10W Sustained

Pictogram wall mount single sided complete

DIR10MPSS 10W Maintained

DIR10SPSS 10W Sustained

DIR10NMPSS 10W Non-Maintained

Pictogram ceiling mount double sided complete

DIR10MPDS 10W Maintained

DIR10SPDS 10W Sustained

DIR10NMPDS 10W Non-Maintained

Accessories

DIRPSS Diffuser wall mount c/w Picto inserts

DIRPDS Diffuser ceiling mount c/w Picto inserts

DIRSS Diffuser wall mount opal only

DIRDS Diffuser ceiling mount opal only

DIRPPSS Director inserts packet, wall mount

DIRPPDS Director inserts packet, ceiling mount

WGWE Wall mount wire guard

WGCE Ceiling mount wire guard

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

DIR10MPSS C0 D5 7.8 8 8.1 8.2 8.2 8 7.7 7.3 5.7 1.6C90 E3.2 6 6.2 6.4 6.6 6.6 6.6 5.8 5.8

DIR10MPDS C0 D6.3 8.6 8.8 9 9.1 9.2 9.2 9 8.7 7.7 5.7C90 E5 6.6 7.2 7.4 7.8 8.2 8.4 8.4 8.2 7 6.8

DIR10SPSS C0 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1C90 E5 6.6 7.2 7.4 7.8 8.2 8.4 8.4 8.2 7 6.8

DIR10SPDS C0 D5 7.8 8 8.1 8.2 8.2 8 7.7 7.3 5.7 1.6C90 E5 6.6 7.2 7.4 7.8 8.2 8.4 8.4 8.2 7 6.8C180 D6.3 8.6 8.8 9 9.1 9.2 9.2 9 8.7 7.7 5.7

DIR10M + DIRDS C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 E12.5 8 8.8 9.4 10 11 11.4 12 12.4 13 12.8 11.6

All pictogram inserts

Page 7: Emergency Brochure Final LR 20-10-10

Technical

5EmergencyMax Dim(mm)

5Emergency

Page 8: Emergency Brochure Final LR 20-10-10

Technical

6 Emergencymax dim(mm)

Traditional style Exit luminaire complete with energy efficient LED technology.

Director LED

Features• LED long life Exit sign, 50,000hrs• Quick connect removeable gear tray• Surface mount Wall/ Ceiling• Injection moulded ABS housing and acrylic diffuser

with Pictogram Legends• Maintained • Viewing Distance 24M• NiCad high temperature battery system

IP20

2.0kg 380 x 160 x 220

• Optional Opal Diffuser included• A complete ‘One Box’ solution including body,

diffuser and all pictogram inserts

ApplicationsGeneral purpose interior exit luminaire, commercial buildings, shops, carparks etc.

Product Codes

Code Version

DIRLEDPSS Director LED Picto Wall Mount

Maintained Exit

DIRLEDPDS Director LED Picto Ceiling Mount

Maintained Exit

Accessories

Diffusers:

DIRPSS Diffuser wall mount incl. Picto Inserts

DIRPDS Diffuser Ceiling mount incl. Picto Inserts

DIRSS Diffuser wall mount Opal only

DIRDS Diffuser Ceiling mount Opal Only

DIRPPSS Director Inserts Packet, Wall mount

DIRPPDS Director Inserts Packet, Ceiling mount

WGWE Wall mount wire gaurd

WGCE Ceiling mount Wire GaurdAll pictogram inserts

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6

DIRLEDPSS C0 E2.5 5.6 5.8 5.8 6 5.8 5.2 5.2 4.6C90 E2.5 5.6 5.8 5.8 6 5.8 5.2 5.2 4.6C180 B2.5 3.7 3.8 3.8 3.8 3.6 3.2 2.4

DIRLEDPDS C0 D4 7.2 7.3 7.3 7.3 7.2 6.9 6.5 5.8 3.1C90 D5 7.8 8 8.1 8.2 8.2 8 7.7 7.3 5.7C180 D4 7.2 7.3 7.3 7.3 7.2 6.9 6.5 5.8 3.1

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Page 9: Emergency Brochure Final LR 20-10-10

Technical

7EmergencyMax Dim(mm)

Product Codes

Code Version

A stylish, quick connect fluorescent exit luminaire compliant toAustralian emergency lighting standards AS/NZS2293.

Stingray

Features• Energy efficient lamp 10W fluorescent• Quick slide connect installation• Surface mount, wall or ceiling mounting options• Maintained or sustained circuits• Viewing distance 24M• Complete ‘one box’ solution, including diffusers and

Picto inserts

ST10MP 1 x 10W Maintained single sided

ST10M2P 1 x 10W Maintained double sided

ST10SP 2 x 10W Sustained single sided

ST10S2P 2 x 10W Sustained double sided

STT10MP 1 x 10W Maintained single sided theatre

ST10M 1 x 10W Maintained

Accessories

WGWE Wall exit wire guard

WGCE Ceiling exit wire guard

EXCB Cantilever bracket

99023330 Rod suspension white

99023360 Rod suspension black

DIRPPSS Pictogram inserts single sided

DIRPPDS Pictogram inserts double sided

Spare Parts

BP2S Battery 2.4V Nicad, 2 cell

99002656 lamp 10W Fluorescent

IP20

3.0kg 395 x 81 x 240

• Polycarbonate housing and diffuser• Compliant to AS/NZS2293

ApplicationsCommercial office areas, apartment buildings, shopping centres & arcades, cinema’s & halls and internal carparks.

Picto decals included

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5

ST10MP C0 E1.25 4.2 4.2 4 3.6 3C90 B1 2.4 2.2 1.8 1.1

ST10M2P C0 E2 5.2 5.2 5.4 5.2 4.6 4.8 4C90 B1.6 3.1 3.1 3 2.8 1.9

ST10SP C0 E1.25 4.2 4.2 4 3.6 3C90 B1 2.4 2.2 1.8 1.1

ST10S2P C0 E2 5.2 5.2 5.4 5.2 4.6 4.8 4C90 C2 4.1 4.1 4.1 3.9 3.3 2.6

Cantilever BracketEXCB

Tough polycarbonate lens

Page 10: Emergency Brochure Final LR 20-10-10

Technical

8 Emergencymax dim(mm)

Product Codes

Code Version

Modern & Stylish Quick connect LED Exit Luminaire complete with Diffuser and Pictogram Legend compliant to Australian Standards AS/NZ2293.

Stingray LED

Features• LED long life Exit sign, 50,000hrs• Quick slide connect installation• Surface mount Wall/Ceiling• Maintained operation• Viewing distance 24M• Complete One Box solution, including

diffusers and Picto inserts• NiCad high temperature battery system

STLED Maintained

STTLED Maintained Theatre

Accessories

WGWE Wall exit wire guard

WGCE Ceiling exit wire guard

EXCB Cantilever bracket

99023330 Rod suspension white

99023360 Rod suspension black

DIRPPSS Pictogram inserts single sided

DIRPPDS Pictogram inserts double sided

• Compliant to Australian Standards AS/NZ2293.• Polycarbonate housing and diffuser

ApplicationsCommercial office areas, apartment buildings, Shopping Centres & Arcades, Cinema’s & Halls, Caparks etc.

Picto decals included

Cantilever BracketEXCB

Polycarbonate housing and diffuser

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6

STLED C0 D4 7.2 7.3 7.3 7.3 7.2 6.9 6.5 5.8 3.1C90 D3.2 6.5 6.6 6.6 6.5 6.2 5.8 5.1 4.1C180 D4 7.2 7.3 7.3 7.3 7.2 6.9 6.5 5.8 3.1

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

IP20

3.0kg 395 x 81 x 240

Page 11: Emergency Brochure Final LR 20-10-10

Technical

9EmergencyMax Dim(mm)

Technical

Product Codes Dim

Code Version (mm)

The Futcha 5 is a high performance louvred luminaire for T5 lamp technology, incorporating LED emergency.

Futcha 5 LED

Features• Class leading efficiency enabling BCA and Greenstar

compliant designs• Suitable for Philips 25W ECO lamp• Full parabolic high purity aluminium louvres• Sturdy low profile body of phosphated steel with

high reflectivity• Electronic control gear, options for Analogue, DSI

and DALI• Sensors can be housed in the luminaire• Options for soft wiring

F5114MBA4EFA 1 X 14W T5 590 x 590 x 60

F5214MBA4EFA 2 X 14W T5 590 x 590 x 60

F5128MBA4EFA 1 X 28W T5 1189 x 590 x 60

F5228MBA4EFA 2 X 28W T5 1189 x 590 x 60

F5124MBA4EFA 1 X 24W T5 1189 x 590 x 60

F5224MBA4EFA 2 X 24W T5 1189 x 590 x 60

IP20

5.0kg 1189 x 294 x 60

• Plaster mounting with Pierlite Plaster Master Frame• 1.5m flex & 3 pin plug as standard• Energy efficient high output 3 watt LED / Non

Maintained• Compliant to AS/NZS2293

ApplicationsGeneral commercial interiors, office, corridors, retail stores and shopping centres.

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

FFRLED C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFRLEDBK C0 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

FFSLEDPK C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFSLEDAK C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFRLED / optical system

Power SpecificationsInput voltage and tolerance 230V AC +/- 10

Nominal frequency 50/60Hz

Nominal power 8.3 (16hr)

Consumption VA 2.9

Battery NiMH 1700mAh

Battery operating temp -20°C to +70°C

Battery Voltage 4.8V

Battery A/hr rating 1700mAhr (run time 2.5hr)

Battery Charging Dual rate ~170mA then pulse 1min/30min

FFRLED C0/C90 D25

Page 12: Emergency Brochure Final LR 20-10-10

Technical

10 Emergencymax dim(mm)

LED Firefly

Product Codes Dim Mass

Code Version (mm) (kg)

Versatile non-maintained LED emergency luminaire compliant to AS/NZS2293.

Features• Energy efficient high output 3 watt LED• Easy installation via 3 pin flex and plug• Recessed or surface mount options• Non corrosive polycarbonate housing and reflector• High performance lens system,

providing D25/D25 spacing• Low power consumption and maintenance• Fully self-contained control circuit, complete with

flex and plug• Optional DALI maintained systems available 114 mm Cutout non-maintained recessed model

FFRLED 3W White 140 x 48 0.35

FFRLEDBK 3W Black 140 x 48 0.35

114 mm Cutout maintained recessed model

FFRLEM 3W White recessed 140 x 48 0.35

Non-maintained Surface mount complete

FFSLEDPK 3W White Polycarbonate 159 x 85 0.48

FFSLEDAK 3W White Alloy 159 x 85 0.90

Maintained surface moutnt complete

FFRLEMAK 3W Surf. Mt Alloy Can Mtd 159 x 85 0.90

AccessoriesFFLEDVK Vandal resistant kit

FFSLEDPB Surface Mount Polycarbonate black can only

99023330 White Pole Suspension kit 1600mm

99023360 Black Pole Suspension kit 1200mm

FFSLEDDISC Suspension cover disc

99015840 Security screws (3 pack) for alloy SM CAN option

99023660 TORX SS Screw (3 pack) for FFSLEDAK

IP20

0.90kg 159 x 85

• Suspension kit and tamper proof options available• Compliant to AS/NZS2293• Circuit rated system life 50 000 hrs• Black theatre options available

ApplicationsCommercial and interior applications, coastal environments, apartments, shopping centres, hospitality, prisons and hospitals.

Power SpecificationsInput voltage and tolerance 230V AC +/- 10

Nominal frequency 50/60Hz

Nominal power 8.3 (16hr)

Consumption VA 2.9

Battery NiMH 1700mAh

FFRLED C0/C90 D25

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

FFRLED C0 C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFRLEDBK C0 CO D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 C90 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

FFSLEDPK C0 C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFSLEDAK C0 C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFRLEM C0 CO D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 C90 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

Tough polycarbonate body

Battery operating temp -20°C to +70°C

Battery Voltage 4.8V

Battery A/hr rating 1700mAhr (run time 2.5hr)

Battery Charging Dual rate ~170mA then pulse 1min/30min

Page 13: Emergency Brochure Final LR 20-10-10

FFLEDVK / Recessed vandal option

99023330 White Pole Suspension kit 1600mm 99023360 Black Pole Suspension kit 1200mm

FFRLEDBK / FFSLEDPB Black surface mount option

11Emergency

FFSLEDPK / Surface mount white

Page 14: Emergency Brochure Final LR 20-10-10

Technical

12 Emergencymax dim(mm)

Firefly®

Product Codes Dim

Code Version (mm)

Versatile non-maintained emergency luminaire providing an economical solution for conventional commercial applications.

Features• Lamp 8 watt tungsten halogen• Steel white polyester coated housing with highly

reflective white powder coat finish• ’Mouse trap’ mounting spring clips• Non-maintained operation• All recessed models are supplied with flex and plug• Filament failure indication standard on all models• Recessed or surface mounted• Small (85mm) or large (140mm) reflector

heads available• Compliant with AS/NZS2293

Non-maintained recessed reflector

FF608 8W T.H. NiMH 140

FF608TH 8W T.H. NiMH - Black theatre 140

FFC608 8W T.H. NiMH 85

FF608S 8W T.H. NiMH battery, split pack 85

FF608SLR 8W T.H. NiMH battery, split pack 140

FF608CR 8W T.H. Weatherproof / Coolroom 140

FF608LA 8W T.H. Lead acid - reflector 140

Non-maintained surface mount

FFSQ608 8W T.H. NiMH 200 x 46

FFSQ6085P1 8W T.H. NiMH Black 200 x 46

AccessoriesNon-maintained recessed reflector

FF608 8W T.H. NiMH 140

FF608TH 8W T.H. NiMH - Black theatre 140

FFC608 8W T.H. NiMH 85

FF608S 8W T.H. NiMH battery, split pack 85

FF608SLR 8W T.H. NiMH battery, split pack 140

FF608CR 8W T.H. Weatherproof / Coolroom 140

FF608LA 8W T.H. Lead acid - reflector 140

IP20

0.40kg 200 x 46

ApplicationsAll commercial and interior applications, apartments, shopping centres, hospitality, prisons and hospitals.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

FF608 C0 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6C90 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6

FFC608 C0 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6C90 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6

FF608S C0 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6C90 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6

FF608CR C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 C10 7.3 7.7 8 8.3 8.8 9 9.1 9.2 9.1 7.5

FF608LA C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 C10 7.3 7.7 8 8.3 8.8 9 9.1 9.2 9.1 7.5

FFSQ608 C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 C10 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5

Page 15: Emergency Brochure Final LR 20-10-10

Technical

13EmergencyMax Dim(mm)

Product Codes

Code Version

DOT 1250/EM is a high performance, energy efficient downlight with emergency capabilities.

DOT 1250 - Emergency

Features• Easy to install, including accessories• Maintained emergency circuit• Easy downlight removal system• High temperature thermo plastic control gear housing• High temperature lampholder, passivated, heavy gauge

pressed steel mounting legs• High purity, post anodised bright aluminium reflector• Electronic control gear• Energy efficient 2 x 26W 4 pin• Compact fluorescent lamps

1250/02/ECG/EM-DOT1250 2 x 26W Maintained

IP20

0.9kg 192 x 128

• Complete with flex and plug

ApplicationsOffices, boardrooms, foyers and reception areas, retail outlets. medical centres and hospitals.

175mm dia. hole cut out

128m

m

Remote Control Gear

Emergency Option available - tested to AS/NZS 2293.3.1995 Emergency Classification in accordance with Appendix CSection 3:- CO A8 C90 A10 IES file available C180 A6.3 on request

Product Code Classification Mounting Height in Metres

2.1 2.4 2.7 3 3.6 4 4.5 5 6

1250/02/ECG/EM-DOT1250 C0 A8 4.8 5.1 5.4 5.6 5.9 6.1 6.2 6.3 6.1

C90 A10 5 5.4 5.7 6 6.4 6.6 6.8 7 7

C180 A6.3 4.5 4.8 5 5.2 5.4 5.5 5.6 5.5 5

Page 16: Emergency Brochure Final LR 20-10-10

Technical

14 Emergencymax dim(mm)

Product Codes

Code Version

Versatile fluorescent batten with multiple options designed for use in general commercial interiors.

Nipper Emergency

Features• Energy efficient lamps 18W and 36W fluorescent• End to end mounting• Maintained, Non-maintained and Sustained available• Quarter turn ’quick release’ reflector and Quick release

diffuser end cap• Large 3 way tunnel terminal block• Rolled cable entry - no grommets required• Wide body version width is designed to cover flush mount

junction box installationsBare Batten

PN218M 2 x 18W Combined maintained

PN136M 2 x 36W Combined maintained

PN236M 2 x 36W Maintained

PN118NM 1 x 18W Non-maintained

PN136NM 1 x 36W Non-maintained

Diffused Batten

PND218M 2 x 18W Maintained

PND136M 1 x 36W Maintained

PND236M 2 x 36W Combined maintained

PND118NM 1 x 18W Non-maintained

PND136NM 1 x 36W Non-maintained

Accessories

Wire Guards Available

Diffuser Kits Available

Spare Parts:

BP4S Battery 4.8V NiCad, 4cell

P4S6 Battery 4.8V NiMH, 4cell (suits PN118NM)

IP20

3.4kg 1229 x 52 x 92

• Wire guards, reflectors and industrial options available• Compliant to AS/NZS2293

ApplicationsDomestic, retail stores and outlets, garages, food processing areas, change rooms and general commercial areas.

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

PN118NM C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

PN218M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

PN136NM C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

PN136M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

PN236M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

Page 17: Emergency Brochure Final LR 20-10-10

15Emergency

Page 18: Emergency Brochure Final LR 20-10-10

Technical

16 Emergencymax dim(mm)

Product Codes

Code Version

Square sided batten with energy efficient T5 lamp technology and emergency lighting capabilities.

High 5® Emergency

Features• High performing photometric distribution in either bare or

diffused options• The body is a cold rolled steel channel, finished in white

polyester powder coat with UV stabilised polycarbonate plastic end caps

• Unique diffuser removal system for easy lamp change• Quarter turn quick release reflector• Large 3 way tunnel terminal block• Rolled cable entry no grommets required• Energy efficient T5 lamp fluorescent circuit• Compliant to AS/NZS2293• Wide body assembly is designed to cover flush mount

HI5228BE4M 28W Bare, Maintained

HI5228BE4S 28W Bare, Sustained

HI5228DE4M 28W, Diffused Maintained

HI5228D/4N 28W Diffused, Maintained

HI5228DE4S 28W, Diffused, Sustained

HI5128BE4M 28W 28W Bare, Maintained

HI5128BE4N 28W Bare, Non-Maintained

HI5128DE4M 28W Diffused, Maintained

HI5128D/4N 28W, Diffused, Non-Maintained

HI5114B/4N 4W, Bare, Non-Maintained

HI5114D/4N 14W, Diffused, Non-Maintained

Hi5214BE4MX1 14W, Bare, Combined- Maintained

HI5214DE4MX1 14W, Diffused, Combined- Maintained

IP20

4.0kg 1229 x 102 x 101

junction box installations• Optional light movement and IR sensor capabilities• True end to end mounting possible with knockouts

for wiring• Optional DALI maintained systems available

ApplicationsGeneral commercial interiors, factories, warehouses, shopping centres, stairwells and interior carparks.t

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Product Code Classification Mounting Height in Metres - Bare2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

HI5114B/4N C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5114BE4M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5214BE4MX1 C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

HI5128BE4N C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5128BE4M C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5228BE4M C0 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3180 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3

HI5228BE4S C0 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3180 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3

Product Code Classification Mounting Height in Metres - Diffused2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

HI5114DE4M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5214DE4MX1 C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

HI5128D/4N C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5128DE4M C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5228D/4M C0 D125 24.5 25.6 27.5 28.3 30.1 31.2 32 34 35.5 37.8 40.8C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1180 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5

HI5228DE4S C0 D125 24.5 25.6 27.5 28.3 30.1 31.2 32 34 35.5 37.8 40.8C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1180 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5

Diffused model

Page 19: Emergency Brochure Final LR 20-10-10

Technical

Product Code Classification Mounting Height in Metres - Bare2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

HI5114B/4N C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5114BE4M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5214BE4MX1 C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

HI5128BE4N C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5128BE4M C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5228BE4M C0 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3180 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3

HI5228BE4S C0 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3180 D100 22.7 23.7 24.6 25.5 27 27.9 28.9 29.8 31.4 33.7 35.3

Product Code Classification Mounting Height in Metres - Diffused2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

HI5114DE4M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

HI5214DE4MX1 C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

HI5128D/4N C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5128DE4M C0 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

HI5228D/4M C0 D125 24.5 25.6 27.5 28.3 30.1 31.2 32 34 35.5 37.8 40.8C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1180 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5

HI5228DE4S C0 D125 24.5 25.6 27.5 28.3 30.1 31.2 32 34 35.5 37.8 40.8C90 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1180 D160 26.6 27.8 28.9 29.9 31.7 32.8 34 35.1 37.1 40.24 42.5

17Emergency

Page 20: Emergency Brochure Final LR 20-10-10

Technical

18 Emergencymax dim(mm)

Technical

18 Emergencymax dim(mm)

Product Codes

Code Version

Premium square sided bare batten, wide body, finished in white powder coat with white ABS end caps allowing for easy end to end mounting.

Regency Bare

Features• Energy efficient T5 and T8 fluorescent lamps• End to End mounting Roll formed steel channel in white

polyester powder coat housing• Maintained, Combined Maintained, Combined Non-

Maintained or Non-Maintained• Lamp holder end caps have knock outs with moulding

provision in the diffuser end caps to enable wiring and flush end to end mounting

• Compliant to AS/NZS2293

RY118M 1 X 18W Maintained

RY118NM 1 x 18W Non-Maintained

RY218M 2 x 18W Combined-Maintained

RY218S 2 x 18W Sustained

RY136M 1 x 36W Maintained

RY236S 2 x 36W Sustained

RY158M 1 x 58W Maintained

RY158NM 1 x 58W Non-Maintained

RY258M 2 x 58W Combined Maintained

RY128M 1 x 28W T5 Maintained

RY128NM 1 x 28W T5 Non-Maintained

RY228M 2 x 28W T5 Maintained

RY228S 2 x 28W T5 Sustained

Accessories

White powder coated wire guard

PHWG218 suits RY118/218

PHWG236 suits RY136/236

PHWG258 suits RY158/258

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit 18W/36W/58W

BP8S2 9.6V NiCad, 8cell to suit 28W and 35W

IP20

3.1kg 1227 x 101

ApplicationsCommercial interiors, retail, carparks, passageways, light industrial warehousing.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

RY118M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

RY118NM C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

RY218M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

RY218S C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

RY136M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

RY136NM C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

RY236M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

RY236S C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

RY158M C0 D80 21.1 22 22.8 23.6 25 25.8 26.7 27.5 28.9 30.9 32.1C90 C80 12.7 13.5 14.4 15.1 16.5 17.3 18.3 19.1 20.7 23.6 24.7

RY258M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C100 13.4 14.3 15.2 16 17.5 18.4 19.4 20.4 22.1 24.8 26.7

Dim (mm)

1 x 18W T8 620 x 105 x 92

2 x 18W T8 620 x 105 x 92

1 x 36W T8 1228 x 105 x 92

2 x 36W T8 1228 x 105 x 92

1 x 58W T8 1529 x 105 x 92

2 x 58W T8 1529 x 105 x 92

Page 21: Emergency Brochure Final LR 20-10-10

Technical

19EmergencyMax Dim(mm)

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

RYD118M C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 8.9 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12

RYD118NM C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 8.9 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12

RYD218M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C20 8.9 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12180 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5

RYD218S C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C20 8.9 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12180 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5

RYD136M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

RYD136NM C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5

RYD236M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

RYD236S C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

RYD158M C0 D80 21.1 22 22.8 23.6 25 25.8 26.7 27.5 28.9 30.9 32.1C90 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5

Product Codes

Code Version

Premium square sided diffused batten, wide body, finished in white powder coat with white ABS end caps allowing for easy end to end mounting.

Regency Diffused

Features• Energy efficient T5 and T8 fluorescent lamps• Tough Y12 acrylic diamond pattern diffuser retained

by white polycarbonate end caps• End to end mounting, roll formed steel channel in

white polyester powder coat housing• Maintained, combined maintained, combined non-

maintained or non-maintained• Compliant to AS/NZS2293• Lamp holder end caps have knock outs with

moulding provision to enable wiring and flush end

to end mountingRYD118M 1 X 18W Maintained

RYD118NM 1 x 18W Non-Maintained

RYD218M 2 x 18W Combined-Maintained

RYD218S 2 x 18W Sustained

RYD136M 1 x 36W Maintained

RYD236S 2 x 36W Sustained

RYD158M 1 x 58W Maintained

RYD158NM 1 x 58W Non-Maintained

RYD258M 2 x 58W Combined Maintained

RYD128M 1 x 28W T5 Maintained

RYD128NM 1 x 28W T5 Non-Maintained

RYD228M 2 x 28W T5 Maintained

RYD228S 2 x 28W T5 Sustained

Accessories

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit 18W/36W/58W

BP8S 2 9.6V NiCad, 8cell to suit 28W and 35W

IP20

3.8kg 1227 x 108 x 101

ApplicationsCommercial interiors, retail, carparks, passageways, and light industrial warehousing.

Dim (mm)

1 x 18W T8 624 x 108 x 101

2 x 18W T8 624 x 108 x 101

1 x 36W T8 1232 x 108 x 101

2 x 36W T8 1232 x 108 x 101

1 x 58W T8 1533 x 108 x 101

2 x 58W T8 1533 x 108 x 101

Page 22: Emergency Brochure Final LR 20-10-10

Technical

20 Emergencymax dim(mm)

Product Codes

Code Version

Single and twin 36W bare tube fluorescent battens designed for ease of installation, and maintenance. The slim line body profile creates an elegant yet simple design.

Deluxe Bare Batten

Features• Energy efficient lamp 36W fluorescent• Slimline profile, powder coated non-discolouring

white housing• Durable polycarbonate non-discolouring end caps with

easy replaceable built in lamp holders• Captive cover plate 1/4 turn clip• Maintained, non-maintained and combined maintained

circuits available

DB136MEL 1 x 36W Maintained

DB236MEL 2x 36W Maintained

DB136NM 1 x 36W Non-maintained

Accessories

White powder coat wire guards

UNBWG136 suit DB136

UNBWG236 suit DB236

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit DB136NM

BP4SNL 4.8V NiCad, 4cell

IP20

4.0kg 1227 x 68 x 90

• Wire guards available• Compliant to AS/NZS2293

ApplicationsGeneral commercial interiors, corridors, carparks, and warehousing.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

DB136M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

DB136NM C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

DB236M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5C180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

Dim (mm)

1 x 36W T8 1228 x 50 x 90

2 x 36W T8 1228 x 68 x 90

DB136MEL

DB236MEL

DB136NM

Page 23: Emergency Brochure Final LR 20-10-10

Technical

21EmergencyMax Dim(mm)

Product Codes

Code Version

Single and twin 36 watt diffused fluorescent battens designed for ease of installation, relamping and maintenance.

Deluxe Diffused

Features• Energy efficient lamp 36W fluorescent• Variable rate charge• Slimline profile, powder coated non-discolouring

white housing• Durable polycarbonate non-discolouring lamp holder end

caps with easy replaceable built in lamp holders• Tough Y12 diamond patterned acrylic diffuser retained by

polycarbonate end caps with unique clip design allowing true end to end mounting

• Captive cover plate 1/4 turn clip

DBD136MEL 1 x 36W Maintained

DBD136NM 1 x 36W Non-maintained

DBD236MEL 2 x 36W Maintained

DBD236SEL 2 x 36W Sustained

Accessories

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit DBD136NM

BP4SNL Battery 4.8V NiCad, 4cell

IP20

4.5kg 1229 x 145 x 110

• Maintained, combined maintained, non-maintained and sustained circuits available

• Compliant to AS/NZ2293

ApplicationsGeneral commercial interiors, retail stores, shopping centres and warehousing.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

DBD136M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C25 9.4 10 10.5 11 11.9 12.4 12.9 13.4 14 14.6 14.2

DBD136NM C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C25 9.4 10 10.5 11 11.9 12.4 12.9 13.4 14 14.6 14.2

DBD236M C0 D63 19.4 20.3 21.2 21.8 23 23.7 24.5 25.2 26.4 28.1 28.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

Dim (mm)

1 x 36W T8 1229 x 86 x 110

2 x 36W T8 1229 x 145 x 110

DBD136MEL

DBD136NM

DBD236MEL

Page 24: Emergency Brochure Final LR 20-10-10

Technical

22 Emergencymax dim(mm)

Product Codes

Code Version

Surface mounted emergency fluorescent luminaire designed with energy efficient T8 technology in compliance with AS/NZS2293.

Unilux

Features• Energy efficient lamp 36W fluorescent• White powder coated steel body• Injection molded prismatic acrylic lens diffuser• Quick release access clips• Combined maintained operation• High performance prismatic lens• Compliant with AS/NZS2293• Low profile body design

EP236M 2 x 36W Combined maintained

Accessories

Spare Parts:

99001550 Replacement diffuser

BP4S Battery 4.8V NiCad, 4cell

IP20

6.2kg 1265 x 100 x 276

ApplicationsLow glare applications, schools, hospitals, TAFE’s, universities, libraries, retail stores, hospitals, banks, general office areas.

1265276

100

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

EP236M C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5

Page 25: Emergency Brochure Final LR 20-10-10

Technical

23EmergencyMax Dim(mm)

Product Codes

Code Version

An economical solution using a variety of lens and louvre options providing a smooth and uniform light distribution.

ET Troffer

Features• Energy efficient lamp 36W fluorescent included• Recessed mount T-Bar system• Powder coated white steel body• Y12 Prismatic lens or optional Y19• Combined maintained operation• Simple to install• 1.5m flex and plug, flat earth• Provisions made for tandem mounting

ET236M 2 x 36W Combined Maintained Recessed, Less lamp and Y12 Diffuser

Accessories

98047100 K12 Prismatic diffuser

99003424 Y19 Prismatic diffuser

HFRM1200X300K12 Y12 Hinged frame diffuser panel

HFRM1200X300K19 Y19 Hinged frame diffuser panel

Spare Parts:

BP4S Battery 4.8V Nicad, 4 cell

IP20

4.3kg 1240 x 97 x 288

• Suitable for plaster mounting using the Pierlite plaster master frame

• Compliant to AS/NZS2293

ApplicationsCommercial interiors, office space and shopping centres.

1240288

97

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

ETT236M C0 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5C90 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5C180 C80 12.7 13.5 14.4 15.1 16.5 17.3 18.3 19.1 20.7 23 24.7

Page 26: Emergency Brochure Final LR 20-10-10

Technical

24 Emergencymax dim(mm)

Product Codes

Code Version

A simple yet stylish non-maintained emergency bulkhead designed for interior and protected exterior use applications.

TR322

Features• Energy efficient lamp 22W circular fluorescent• Surface Mount - wall / ceiling options• UV stabilised opal polycarbonate housing

and diffuser• Mains only versions available• Ideal for apartment corridors, requiring both general

and emergency lighting matched luminaires

TR322NM 1 x 22W Non-maintained

TR322 1 x 22W Mains operation only

Accessories

Spare Parts:

BP4S2 Battery 4.8V Nicad, 4 cell

IP43

1.4kg 250 x 103

• Compliant with AS/NZS2293

ApplicationsInterior and covered exterior use, stairwells & apartment buildings, under eaves and awnings.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

TR322NM C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9

Page 27: Emergency Brochure Final LR 20-10-10

25Emergency

Page 28: Emergency Brochure Final LR 20-10-10

Technical

26 Emergencymax dim(mm)

Product Codes

Code Version

Classic styled luminaire designed for commercial applications in either maintained configuration or mains only.

Condo

Features• Lamp 32W circular fluorescent included• Surface mount wall/ ceiling options• Strong formed steel housing• Highly reflective white powder coat finish• Thick opal acrylic lens with wide distribution• Mains only or Maintained operation• Variable rate charging (variable rate charging)

CD32M 1 x 32W Maintained c/w circular lamp

CD32 1 x 32W Mains operation only

Accessories

Spare parts:

P4S62 Battery 4.8V NiMh, 4 cell

99002671 Lamp 32W Fluorescent Circular

IP40

2.0kg 410 x 105

• Ideal for apartment corridors, requiring both general and emergency lighting

• Compliant to AS/NZS2293

ApplicationsInterior, commercial, apartments, corridors, stairwells.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

CD32M C0 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5C90 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5

Durable formed steel housing

Page 29: Emergency Brochure Final LR 20-10-10

Technical

27EmergencyMax Dim(mm)

Product Codes

Code Version

Versatile emergency luminaire designed for a diverse range of installations requiring low maintenance and energy efficient LED technology.

Features• Lamp high output 3W LED• High performance lens system• Non-maintained operation and maintained• Low power consumption and maintenance• Integral gear and battery• Vandal/tamper proof• Switch mode power supply - reduced power consumption• Energy efficient lamp source• Alloy housing and bracket

HADONELEDM 3W Maintained LED Emergency

HADONELEDNM 3W Non Maintained LED Emergency

Accessories

FFRLED Replacement Non-Maintained emergency light

FFRLEDM Replacement Maintained emergency light

IP65

6.0kg 288 x 198 x 99

• Aluminium face trim• Durable powder coat paint finish

ApplicationsIdeal for feature emergency lighting applications or general emergency lighting around building exteriors and entry statements. Other applications include wall, column or post mounted in exposed positions or used under awnings and space frame structures.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

FFRLED C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

FFRLEM C0 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

HID version shown

Power SpecificationsInput voltage and tolerance 230V AC +/- 10

Nominal frequency 50/60Hz

Nominal power 8.3 (16hr)

Consumption VA 2.9

Battery NiMH 1700mAh

Battery operating temp -20°C to +70°C

Battery Voltage 4.8V

Battery A/hr rating 1700mAhr (run time 2.5hr)

Battery Charging Dual rate ~170mA then pulse 1min/30min

FFRLED C0/C90 D25

FFRLED / optical system

Hades I - LED Emergency

Page 30: Emergency Brochure Final LR 20-10-10

Technical

28 Emergencymax dim(mm)

Flood light emergency luminaire with adjustable beam for commercial applications, requiring aesthetic appeal.

Guardian GR99

Features• Lamp 2 x 9W tungsten halogen• Twin adjustable beam lamps• Polycarbonate body• Non-maintained operation• Complete with flex and plug• Compliant with AS/NZS2293• Integral gear

IP20

6.5kg 335 x 365 x 130

ApplicationsInterior commercial and industrial. Retail stores, public auditoriums, warehouse facilities, factories, airports, and school halls.

Product Codes

Code Version

GR99 2X9W EM FLOOD Non-Maintained

Accessories

Battery 99019703 6V Sealed Lead Acid

Note: Test report LL11247 for spacing distance available.

Test button adjustable beam lamps

Page 31: Emergency Brochure Final LR 20-10-10

Technical

29EmergencyMax Dim(mm)

Flood light emergency luminaire with adjustable beam for commercial applications.

Guardian GR21

Features• Lamp 2 x 21W tungsten halogen• Twin adjustable beam lamps• Formed steel housing• Non-maintained operation• Complete with flex and plug• Filament failure indication• Compliant with AS/NZS2293

IP20

6.5kg 335 x 365 x 130

• Individual test buttons• Integral gear

ApplicationsInterior commercial and industrial. Retail stores, public auditoriums, warehouse facilities, factories, airports, and school halls.

Product Codes

Code Version

GR21 2X21W Non-Maint EmergFlood.

Accessories

Battery 2 x 99019704 12V Sealed Lead Acid

Options Heads can be remote mounted.

Note: Test report LL11247 for spacing distance available.

Filament failure indication Twin swivel heads

Page 32: Emergency Brochure Final LR 20-10-10

Technical

30 Emergencymax dim(mm)

Product Codes

Code Version

A versatile IP65 fluorescent exit luminaire, designed for 16m viewing distance, in compliance with AS/NZS2293.

Weatherlux®

Features• Energy efficient lamp 8W fluorescent• Durable white polycarbonate body with quick connect

removable gear tray• Surface wall or ceiling mount • Pictogram 16m viewing distance complete

polycarbonate diffuser• IP65 weatherproof construction• Removable gear tray

WL8NM 1 x 8W Non-Maintained (body only)

WL8M 1 x 8W Maintained (body only)

WL8S 2 x 8W Sustained (body only)

Accessories

Pictogram Diffusers

WL01P Straight from here

WL02P Left from here

WL03P Right from here

WL04P Ceiling Picto single sided

WL08DPR Ceiling Picto double sided Right

WL06PR Ceiling Picto single sided Right

WL07DP Ceiling Picto double sided

WL05PL Ceiling Picto single sided Left

Note: Must specify diffuser required.

Spare parts:

BP2S 2.4V NiCad, 2 cell

IP65

3.0kg 368 x 102 x 150

• Tamper proof screws available as an option• Maintained, non-maintained and sustained circuits available

ApplicationsDamp environments, warehouses, production facilities, car parks, schools and coastal areas.

Choice of picto decals available

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

WL8M + WL01P C0 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1C90 E5 6.6 7.2 7.4 7.8 8.2 8.4 8.4 8.2 7 6.8

WL8S + WL01P C0 D10 10.2 10.6 10.9 11.1 11.4 11.5 11.6 11.6 11.2 10.3 8.9C90 C10 7.3 7.7 8 8.3 8.8 9 9.1 9.2 9.1 7.5C180 E3.2 6 6.2 6.4 6.6 6.6 6.6 5.8 5.8

WL8M + WLO C0 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 11.3 7.6C90 E12.5 8 8.8 9.4 10 11 11.4 12 12.4 13 12.8 11.6

Page 33: Emergency Brochure Final LR 20-10-10

Technical

31EmergencyMax Dim(mm)

Product Codes

Code Version

Weatherproof IP65 exit luminaire designed with energy efficient LED technology housed in a rugged vandal resistant casing.

Features• High output strip LED• Ceiling or wall mount• Robust steel fabrication with UV resistant powder coating• Low power consumption and maintenance• Integral gear and battery• New slim, aesthetic and practical design• One box solution, complete with all Picto inserts• Special design applications available• Tough LEXAN diffuser

WELED2VM24 weatherproof LED exit, vandal resistant,

pictogram - 24m viewing distance

WELED2VM24B weatherproof LED exit, theatre, vandal

resistant, pictogram

WELED2VM24R weatherproof LED exit, remote gear,

vandal resistant, pictogram

WELED2VM40 weatherproof LED exit, vandal resistant,

pictogram - 40m viewing distance

Black theatre WELED2VM24X1

Remote WELED2VM24X2

IP65

3.0kg 441 x 299 x 33

• Vandal/Tamper proof fixing available• Theatre version available

ApplicationsCommercial, external and industrial applications, railway tunnels and platforms, carparks, prisons, courts and mining.

391391WP LED Exit

441mm33mm

229mm 286mm

Power SpecificationsInput voltage and tolerance 230V AC +/- 10Nominal frequency 50/60HzNominal power 6.5WConsumption VA 11.1Battery NiMH 1800mAhBattery operating temp -20°C to +70°CBattery Voltage 4.8VBattery A/Hr rating 1800mAhr (run time 2.5hr)Battery Charging Dual rate ~170mA then pulsePower Factor 0.592 LPF

Robust steel fabricated body

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Warden LED

Page 34: Emergency Brochure Final LR 20-10-10

Technical

32 Emergencymax dim(mm)

Product Codes

Code Version

Vandal resistant emergency fluorescent exit luminaire designed for arduous environments in compliance with AS/NZS2293.

Vandal X IP65

Features• Energy efficient lamp 10W fluorescent• Strong die-cast aluminium housing coated in polyester

white powder coat• 6mm polycarbonate pictogram diffuser with 24M

viewing distance• Tamper proof security screws• Fully approved to AS2293 thermal

& illuminance requirements• Impact tested and approved

EVC210S 2x10W sustained

Accessories

Pictogram Diffusers

EVC01P Straight on from here

EVC01PL Left from here

EVC01PR Right from here

Note: Must specify diffuser required.

Spare Parts

BP2S Battery 2.4V Nicad, 2 cell

IP65

3.0kg 360 x 180 x 170

ApplicationsHigh risk, arduous environments, prisons, detention centres, public access areas, railway stations and heavy industrial areas.

Tamper proof tri-lobal screw

360mm

180mm

Strong die-cast aluminium housing

Choice of picto decals available

Page 35: Emergency Brochure Final LR 20-10-10

Technical

33EmergencyMax Dim(mm)

Product Codes

Code Version

Oversize jumbo exit luminaire designed for 32m viewing distances compliant to AS/NZS2293.

Extreme

Features• Energy efficient lamp 18W fluorescent• Steel - white polyester powder coated housing with

removable gear tray• Polycarbonate pictogram diffuser with 32m

viewing distance• Wall or ceiling mount options• Maintained, non-maintained and sustained available• Single or double sided viewing options• Compliant to AS/NZS2293

EX18M 1x18W Maintained

EX18NM 1x18W Non-Maintained

EX18S 2x18W Sustained

Accessories

Pictogram Diffusers

EX01P Straight on from here

EX02P Left from here

EX03P Right from here

WGWE18 Wall Exit wire guard

Note: For wall/ceiling mount, single sided - select and specify one diffuser panel

For ceiling mount double sided, select and specify two diffuser panels.

Battery

BP4S2 4.8V NiCad, 4CELL

IP20

3.0kg 640 x 290 x 83

ApplicationsLarge scale commercial environments, public areas, supermarket, department stores, convention, exhibition and entertainment centres, factories, warehouses and industrial sites.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

EX18M + EX01 C0 D6.3 8.6 8.8 9 9.1 9.2 9.2 9 8.7 7.7 5.7C90 E3.2 6 6.2 6.4 6.6 6.6 6.6 5.8 5.8

EX18M + 2xEX01 C0 D5 7.8 8 8.1 8.2 8.2 8 7.7 7.3 5.7 1.6C90 B6.3 5 5.3 5.5 5.7 6 6.1 6.1 6 5.4 4.1

EX18M + EX01P C0 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1C90 E4 6.2 6.6 7 7.2 7.4 7.4 7.2 6.6 7

EX18M + 2xEX01P C0 D6.3 8.6 8.8 9 9.1 9.2 9.2 9 8.7 7.7 5.7C90 E3.2 6 6.2 6.4 6.6 6.6 6.6 5.8 5.8

Convenient test buttons

Page 36: Emergency Brochure Final LR 20-10-10

Technical

34 Emergencymax dim(mm)

Product Codes

Code Version

Class 1 Zone 2 emergency exit luminaire designed for use in IIC gas, dust and ignition proof applications.

EXDN IP66

Features• Energy efficient lamp 10W fluorescent• Durable grey polycarbonate housing with

polycarbonate picto diffuser• Class1 Zone 2, Ex n llC, DIP, Zone 21 & 22• Maintained or Sustained circuits available• Viewing distance 24M• Surface wall mount only• Complies to AS/NZS2293

EXDN110- 1x10W Maintained c/w

EXDN210- 2x10W Sustained c/w

Accessories

Spare Parts:

BP2S Battery 2.4V NiCad, 2 Cell

Diffusers available upon request

IP66

5.0kg 390 x 130 x 190

• Convenient removable gear tray• Large, quick release diffuser screws• End to end conduit access

ApplicationsDesigned for class1, zone 2 applications.

390

190

130

390mm

190mm

130mm

Choice of picto decals available

Page 37: Emergency Brochure Final LR 20-10-10

Technical

35EmergencyMax Dim(mm)

Product Codes

Code Version

An IP65 bulkhead suitable for interior or exterior use, providing resistance to moisture, impact, corrosive dust environments.

Condo Weatherproof

Features• Energy efficient lamp 28W2D fluorescent• Surface mount• Body cast aluminium - available in white or black• UV stabilised, high-impact resistant, opal

polycarbonate diffuser• Silicon gasket for sealing integrity• Stainless steel, allen-head screws• Maintained and Non-Maintained operation

CD28MWT 1 x 28W 2D Maintained White

CD28MBK 1 x 28W 2D Maintained Black

CD28NMWT 1 x 28W 2D Non-Maintained White

CD28NMBK 1 x 28W 2D Non-Maintained Black

Accessories

Spare Parts:

BP4S Battery 4.8V NiCad 4cell

IP65

2.0kg 395 x 225 x 81

• Integral gear and battery compartment• Compliant to AS/NZS2293

ApplicationsWeatherproof applications, commercial exterior, hospitals and large strata residential.

360mm 175mmSilicon gasketPolycarbonate diffuser

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

CD28M C0 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1C90 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1

Page 38: Emergency Brochure Final LR 20-10-10

Technical

36 Emergencymax dim(mm)

Product Codes

Code Version

Corrosion resistant GRP weatherproof fluorescent luminaire designed with high performance T5 and T8 optics.

PWP™ & PWA™

Features• Lamp 18W T8, 36W T8,14W T5, 28W T5, 35W T5• Tough corrosion resistant glass-fibre reinforced

polyester body• UV stabilised high impact polycarbonate

lens (optional acrylic)• Removable steel gear tray/reflector• Polyurethane machine poured foam gasket• Tamper resistant stainless steel (PWP) or polycarbonate

(PWA) diffuser retaining clips• Internal ribbed lens prism• Optional IR and motion sensor capabilities

PWP218M 2 x 18W Combined Maintained

PWP218S 2 x 18W Sustained

PWP136M 1 x 36W Maintained

PWP136NM 1 x 36W Non-Maintained

PWP236M 2 x 36W Combined Maintained

PWP114M 1 x 14W T5 Maintained - wide body

PWP214M 2 x 14W T5 Combined Maintained

PWP128M 1 x 28W T5 Maintained - wide body

PWP228M 2 x 28W T5 Combined Maintained

PWP235M 2 x 35W T5 Maintained

Accessories

Spare Parts:

BP4S Battery 4.8V NiCad, 4cell suits 18W/36W T8

BP6S2 Battery 7.2V NiCad, 6cell suits 14W T5

BP8S2 Battery 9.6V NiCad 8cell, suits 28W & 35W T5

For acrylic models replace ‘P’ in the catalogue with ‘A’ i.e PWP114M becomes PWA114M

IP65

5.4kg 1500 x 172 x 108

• Optional DALI• Compliant to AS/NZS2293• 20mm grommet cable entry at one end• Maintained, non-maintained, combined maintained and

combined maintained available

ApplicationsGeneral weatherproof conditions, wet rooms, food processing areas, industrial plants, car parks.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

PWP218M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

PWP136NM C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

PWP136M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

PWP236M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C32 10 10.7 11.3 11.8 12.8 13.4 14 14.5 15.4 16.4 16.5C180 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

Dim (mm)

1 x 18W T8 697 x 102 x 108

2 x 18W T8 697 x 172 x 108

1 x 36W T8 1307 x 102 x 108

2 x 36W T8 1307 x 172 x 108

2 x 35W T5 1500 x 172 x 108

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Page 39: Emergency Brochure Final LR 20-10-10

Technical

37EmergencyMax Dim(mm)

Product Codes

Code Version

Corrosion resistant GRP weatherproof fluorescent luminaire designed with high performance T8 Optics.

SDW / SDWA

Features• Energy efficient lamp 18W, 26W, 36W fluorescent• Tough corrosion resistant glass-fibre reinforced

polyester body• UV stabilised high Impact polycarbonate lens

(optional acrylic)• Polyurethane machine poured foam gasket• Stainless steel diffuser clips, screw lockable• Internal ribbed prism lens• 20mm grommet cable entry at one end• IP65• Optional DALI maintained

SDW218M 2 x 18W Combined Maintained

SDW218S 2 x 18W Sustained

SDW136M 1 x 36W Maintained

SDW136NM 1 x 36W Non-Maintained

SDW236M 2 x 36W Combined Maintained

SDW236S 2 x 36W Sustained

SDW128M 1 x 28W Maintained

SDW228M 2 x 28W Combined Maintained

Accessories

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit 136NM/M and 236M/S

BP4S2 4.8V Nicad, 4 cell to suit 218M/S

For 45° watershed factory fitted to 36W and 58W acrylic

models suffix ‘WS’, ie. SDW236MWS

For Acrylic diffuser models suffix ‘A’ in catalogue number

after’SDW’136M ie. becomes SDWA136M

IP65

6.5kg 1270 x 177 x 115

• Maintained, combined maintained, sustained and non-maintained

• Food industries - watershed bracket available• Compliant to AS/NZS2293

ApplicationsGeneral weatherproof conditions, wet rooms, food processing areas, dairies, industrial plants, car parks and wharves.

Stainless steel clips

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

SDW218M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

SDW218S C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

SDW136M C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

SDW136NM C0 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5

SDW236M C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

SDW236S C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

Dim (mm)

2 x 18W 657 x 198 x 125

2 x 36W 1267 x 198 x 125

Tough corrosion resistant glass-fibre reinforced polyester body

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Page 40: Emergency Brochure Final LR 20-10-10

Technical

38 Emergencymax dim(mm)

Product Codes

Code Version

IP66 emergency fluorescent luminaire designed for hazardous, and chemical environments.

SDIP

Features• Energy efficient lamp 18W and 36W fluorescent• Class 1 Zone 2, Ex n IIC Zone 21 & 22• Glass-fibre reinforced body• High impact polycarbonate diffuser with stainless

steel diffuser clips, screw lockable• IP66• Complies to AS/NZS2293• Supplied with mount brackets

SDIP218M-DIP 2 x 18W Combined Maintained

SDIP236M-DIP 2 x 36W Combined Maintained

Accessories

Replacement Batteries

BP4S 4.8V Nicad, 4 cell to suit 136NM/M and 236M/S

BP4S2 4.8V Nicad, 4 cell to suit 218M/S

IP66

5.4kg 1270 x 177 x 115

• Dual conduit access facilities• Combined-maintained operation

ApplicationsGrain processing and handling areas, wineries, coal storage and handling sites, wharves and arduous environments.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

SDIP218M-DIP C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

SDIP218M-EXN C0 D50 18 18.7 19.4 20.1 21.2 21.8 22.5 23.2 24.2 25.4 25.9C90 C40 10.6 11.3 11 12.6 13.6 14.3 15 15.6 16.6 17.9 18.5C180 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

SDIP236M-DIP C0 D63 19.4 20.3 21.2 21.8 23 23.7 24.5 25.2 26.4 28.1 28.9C90 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5C180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

SDIP236M-EXN C0 D63 19.4 20.3 21.2 21.8 23 23.7 24.5 25.2 26.4 28.1 28.9C90 C50 11.3 12 11.8 13.4 14.5 15.2 16 16.7 17.9 17.9 18.5C180 D40 16.7 17.4 18 18.6 19.6 20.1 20.8 21.3 22.1 23 23.1

Page 41: Emergency Brochure Final LR 20-10-10

Technical

39EmergencyMax Dim(mm)

Product Codes

Code Version

Low profile IP66 fluorescent weatherproof luminaire designed for hostile and vandal prone environments.

Vandaguard®

Features• Energy efficient lamp 18W, 36W fluorescent• Pressure die-cast marine grade LM20 aluminium

body with separate battery compartment• Robust reeded or clear prismatic

polycarbonate diffuser• Complete with security screws, removable gear tray

and single one piece gasket• Low profile IP66 protection• Maintained, combined-maintained, combined non-

maintained or non-maintained• Complies to AS/NZS2293

VPF118M 1 x 18W Maintained

VPF118NM 1 x 18W Non-Maintained

VPF218M 2 x 18W Combined Maintained

VPF218S 2 x 18W Sustained

VPF136M 1 x 36W Maintained

VPF136NM 1 x 36W Non-Maintained

VPF236M 2 x 36W Combined Maintained

VPF236S 2 x 36W Sustained

Accessories

Spare Parts:

99010318 Battery 9.8V NiCad, 4 cell

BP4S Battery 4.8V NiCad, 4 cell stick

IP66

8.5kg 1310 x 140 x 80

• Dual conduit access• Optional DALI maintained• Optional motion and IR sensor capabilities

ApplicationsPrisons, subways, railway stations and underground carparks.

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

VPF118M C0 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5C90 C16 8.3 8.8 9.3 9.7 10.3 10.7 11 11.3 11.6 11.3 9.6

VPF218M C0 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 C16 8.3 8.8 9.3 9.7 10.3 10.7 11 11.3 11.6 11.3 9.6180 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

VPF136M C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5

VPF136NM C0 D25 14.2 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 8.9 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12

VPF236M C0 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3C90 C25 9.4 10 10.5 11 11.9 12.4 12.9 13.4 14 14.6 14.2180 D32 15.4 16.1 16.7 17.2 18 18.5 19.1 19.5 20.2 20.7 20.3

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Secure access screws

Tough polycarbonate lens

Dim (mm)

1 x 18W T8 670 x 140 x 80

2 x 18W T8 670 x 140 x 80

1 x 36W T8 1310 x 140 x 80

2 x 36W T8 1310 x 140 x 80

Page 42: Emergency Brochure Final LR 20-10-10

Technical

40 Emergencymax dim(mm)

NEW IMAGE

40 Emergency

Page 43: Emergency Brochure Final LR 20-10-10

Technical

41EmergencyMax Dim(mm)

NEW IMAGE

41Emergency

Page 44: Emergency Brochure Final LR 20-10-10

Technical

42 Emergencymax dim(mm)

Product Codes

Code Version

Adverse and weatherproof IP66 fluorescent luminaire designed for hostile, industrial and vandal prone environments.

Vandalux®

Features• Energy efficient lamp 18W, 36W fluorescent• Pressure die-cast marine grade LM20 aluminium body

with (separate battery compartment, 18W only)• Heavy-duty reeded or clear prismatic

polycarbonate diffuser• Removable gear tray• Maintained, combined-maintained, combined non-

maintained or non-maintained• Complete with security screws and single piece gasket• IP66 protection• Standard finished chromate treated APO grey epoxy

powder coat

VP118M 1 x 18W Maintained

VP118NM 1 x 18W Non-Maintained

VP218M 2 x 18W Combined Maintained

VP218S 2 x 18W Sustained

VP136M 1 x 36W Maintained

VP136NM 1 x 36W Non-Maintained

VP236M 2 x 36W Combined - Maintained

VP236S 2 x 36W Sustained

Accessories - see Vandalux adverse section

Spare Parts:

99010318 Battery 4.8V NiCad 4 cell

BP4S Battery 4.8V NiCad 4 cell stick

IP66

6.3kg 1310 x 140 x 120

• Option safety orange body finish available• Complies to AS/NZS2293• Dual conduit access• Optional DALI• Optional motion and IR sensor capabilities

ApplicationsWeatherproof for hostile, industrial and vandal prone environments, railway stations, subways and car parks.

Product Code Classification Mounting Height in Metres2.4 2.7 3 3.6 4 4.5 5 6 8 10

VP118M C0 D16 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5C90 C16 8.8 9.3 9.7 10.3 10.7 11 11.3 11.6 11.3 9.6

VP218M C0 D20 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 C16 8.8 9.3 9.7 10.3 10.7 11 11.3 11.6 11.3 9.6180 D20 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5

VP136M C0 D25 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12

VP136NM C0 D25 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C20 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12

VP236M C0 D32 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3C90 C25 9.4 9.9 10.3 11.1 11.5 12 12.3 12.8 13 12180 D32 14.7 15.3 15.7 16.5 16.9 17.3 17.7 18.1 18.2 17.3

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

Dim (mm)

1x18W T8 670 x 140 x 120

2x18W T8 670 x 140 x 120

1x36W T8 1310 x 140 x 120

2x36W T8 1310 x 140 x 120

Page 45: Emergency Brochure Final LR 20-10-10

43Emergency

Page 46: Emergency Brochure Final LR 20-10-10

Technical

44 Emergencymax dim(mm)

Product Codes

Code Version

Heavy duty IP65/67 bulkhead for adverse applications.

NXS

Features• Energy efficient lamp 18W compact fluorescent• Robust die cast aluminium body• Borosilicate glass diffuser• Non-Maintained operation• Ceiling or wall mount design• Complies to AS/NZS2293• Integral control equipment• 4 x M20 conduit access (industrial)• 4 x M25 conduit access (mining)

NEX118NM 1 x 18W Non-Maintained

Accessories

Spare Parts:

BP4S Battery 4.8V NiCad 4cell

NSXWG Wire guard

NSXV Visor

IP65/67

5.9kg 298 x 193 x 184

• Industrial version IP65• Mining version IP67

ApplicationsIndustrial sites, mine sites and adverse conditions.

298

184

193

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

NEX118NM C0 D20 13.1 13.6 14.1 14.5 15.1 15.5 15.8 16.1 16.4 16 14.5C90 D12.5 11.1 11.5 11.8 12.1 12.5 12.7 12.9 13 12.8 12.3 11.3

Borosilicate glass diffuser

4 x M20 conduit access (industrial)4 x M25 conduit access (mining)

Page 47: Emergency Brochure Final LR 20-10-10

45Emergency

Page 48: Emergency Brochure Final LR 20-10-10

Technical

46 Emergencymax dim(mm)

Product Codes

Code Version

Robust IP65 fluorescent bulkhead designed for weatherproof and adverse applications.

Maxi Pac IP65®

Features• Energy efficient lamp 18 watt compact fluorescent• Removable gear tray• Non-maintained operation or maintained• 20mm cable entry knockouts at both ends• Robust cast aluminium body• Reeded polycarbonate diffuser• Strong versatile bulkhead• Circular compression gasket• Complies to AS/NZS2293

LPC118M 1 x 18W Non-Maintained

LPC118NM 1 x 18W Maintained

Accessories

Spare Parts:

BP4S Battery 4.8V NiCad 4cell

IP65

3.7kg 315 x 220 x 161

• Integral control equipment• Ceiling or wall mount• Colour white

ApplicationsWeatherproof environments, factories, walkways, car parks, and industrial zones.

220 315

161

Product Code Classification Mounting Height in Metres2.1 2.4 2.7 3 3.6 4 4.5 5 6 8 10

LPC118M C0 D16 12.1 12.6 13.4 13.1 13.9 14.1 14.6 14.6 14.6 13.8 11.5C90 D8 9.4 9.7 9.9 10.1 10.3 10.4 10.3 10.2 9.5 8.3 6.1

Robust cast aluminium body

Reeded polycarbonate diffuser

Page 49: Emergency Brochure Final LR 20-10-10

Technical

47EmergencyMax Dim(mm)

Product Codes Dim Mass

Code Version (mm) (kg)

A versatile luminaire using an energy saving compact fluorescent lamp with self-contained emergency circuit.

Metro Emergency

Features• Glass filled Nylon moulded body for strength• Polycarbonate prismatic diffuser with reflector• Silicon gasket provides weather ingress protection• Modular heavy duty gear tray• Twist-off diffuser for easy lamp replacement• Fits Std diameter 34mm pipe spigot• Uses energy saving compact fluorescent lamp• Maintained unit with electronic module• Non maintained or Maintained with integral inverter• Universal bracket supplied with fitting

NON MAINTAINED

METROPLC18NM 18W PLC 490 x 170 x 180 3.0

METROPLC32NM 32W PLC 490 x 170 x 180 3.0

MAINTAINED

METROPLC18MEL 18W PLC 490 x 170 x 180 3.0

AccessoriesAll mounting brackets included.

BP4S2 18W / 32W Non-Maintained battery NiCad

97002252 18W Maintained battery NiCad

IP65

3.0kg 490 x 170 x 180

ApplicationsFor general security lighting around industrial areas, public amenities and high density housing projects. Also suitable for general lighting around mining infrastructure such as conveyors, loaders and gantries.

Wall Corner Pole

105mm 285mm

164mm 100mm

150mm

Page 50: Emergency Brochure Final LR 20-10-10

48Emergency

DIGINET is a simple, intelligent emergency lighting management system designed by industry experts to effectively manage and monitor the status of emergency lighting within a network. DIGINET utilises a DALI international open protocol to communicate between luminaires and the computer software.

Types of applications for a DIGINET system

• Commercial & industrial installations• Low rise office or apartment buildings• Multiple building campuses• Hospitals• Correctional facilities• Educational facilities• Health centres and aged care facilities• Centralised emergency light management

3 x typical system styles

FOOLPROOF INSTALLATIONThe DIGINET System is as simple to install as a non-monitored single point system, just install the emergency lights as per plans and by using a CMS type cabling connection method, the system should not be compromised by poor cable connection. The ‘plug & play’ type cabling will connect to a small wall mounted LCD display computer, then by simply commissioning each product into the computer the system is ready to go.

SELF MONITORINGDIGINET is self monitoring, it can diagnose system and product faults in readiness for maintenance access at either the 6 monthly test or anytime in between.

INDEPENDENT OR COMPLETE-YOUR CHOICEYou can choose whether to cable for an independent DIGINET Emergency Lighting Management system or a Complete DALI Lighting Management system, the cabling and connection remains the same simple method for both systems therefore both systems can connect to the same wiring loop. This will reduce Labor, Cost and confusion.

EASY SYSTEM CONTROLSThe DIGINET system features a unique LCD graphical user interface type computer to control and monitor. This is accessible via ethernet, LAN, WAN etc. The LCD control panel can be located in an electrical/data riser, front desk etc. and accessed on any PC via an allocated IP address over the internet.

SIMPLE AUSTRALIAN STANDARDS COMPLIANCEThe DIGINET emergency lighting management system makes compliance with AS2293.2 and various State and Local regulations very easy. The system is designed to run the required 6 monthly discharge tests, create maintenance logs and run compliance reports to assist in making sure that a crucial building safety system stays operational. The system provides reliable data that is not compromised by human error and makes it quick and easy to access.

Small projects <60 points

Medium projectsup to 120 points

Large projectsup to 600 pointsNB: For projects +600 units refer Pierlite Australia

Page 51: Emergency Brochure Final LR 20-10-10

Technical

49EmergencyMax Dim(mm)

Product Codes

Code Version

DIGINET DALI Touch Screen Control Panel

DIGINET DALI Emergency Control Panel

Features• Simple one touch control system• Automatic initiation and logging of tests• User friendly colour interface• On screen luminaires health status• Up to 120 emergency lighting points per panel • Interconnect up to 10 Panels using

Ethernet backbone• The DIGINET product has been designed in accordance

with International DALI standard IEC 62386.

99005257 DIGINET DALI Touch Screen Control Panel

Accessories

Power Supply

99005256 DALI PS1 Surf Remote (200MA)

99005255 PS DALI DIN Rail

IP20

0.92kg 200 x 150 x 20

ApplicationsSmall to medium commercial & industrial installations, low rise office or apartment buildings, multiple building campuses, small to medium public buildings, health centres and aged care facilities.

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

EXIT SIGN DALI PSU

24-48V DC10VA

DIGINETTOUCH SCREEN

CONTROLLER

DALI PSU EXIT SIGN EMERGENCY LIGHT

NL

DADA

DADA

EMERGENCY LIGHT

Page 52: Emergency Brochure Final LR 20-10-10

Technical

50 Emergency

Cable and Connector Technical specification:

Simplicity, flexibility and efficiency is the key to installation and interconnection of a DIGINET DALI management system.

DIGINET Cable Management Options

Features• Simplifies the wiring and provides

Plug & Play connectivity• 5 way hard and soft wiring solutions available• Reduce wastage in materials• Luminaires and interconnecting cables can be

installed at the same time• Combined lighting, power, control and

communication wiring eliminates the need for separate Data Cabling.

• Add Luminaires or Devices by simply plugging in.• Reduce the quantity and variety of wiring required

in an installation.

Mains 240VAC. 16A and 20A versions available 5 core wiring which typically consists of 3 x conductors for A, E, N and 2 x conductors for DALI (min 1.5mm2) allowing for up to 64 DALI Addresses over 300 metres.

Contact your local Pierlite office for further details

Applications5 way soft and hard wiring connectivity solutions are available for commercial, residential, infrastructure or industrial lighting applications.

It is highly recommended that in every installation, 5 core cabling such as 5 core round, 5 core flat or 5 core structured cabling solution is taken to each zone and then routed to each luminaire. This gives total flexibility and makes the project future proof.

CLIENT: GERARD LIGHTING

CONCEPT: 02.09.09

BRAND: iLP- INTELLIGENT LIGHTING SOLUTIONS

PRODUCT: iLP LOGO R

CONTACT: Vanessa Cotton

Custom Cartons

19 East Street

Brompton SA 5007

Tel: 08 8348 2967

Fax: 08 8348 2977

Email: [email protected]

5 core flat

QF1

QF1

QF3 Lead hard wired to fitting. 3x2.5mm(A,N,E) & 2x1.5mmDali.w

2

2

Light FittingQF5 Interceptor allowing splitting of circuits/new power supply.

QF3 & QFS3 hard wired to fitting.

QF3a Lead hard wired to fitting. 5x1.0mm ,maximum 2.5metres.

2QF3b Lead mates with QF6 Plug in fitting. 3x2.5mm(A,N,E) & 2x1.5mm Dali.

2

2

QF3c Lead mates with Qf6 Plug in fitting. 5x1.0mmmaximum length 2.5 metres.

2

QF4 Hard wired to fitting.B5T Fits directly into QF6 B5.2 Connector - Field

New power supply

Plugging multiple A5T reduces the No. of QF2 leads required.

QF2 A5T

QF6

Page 53: Emergency Brochure Final LR 20-10-10

51TechnicalEMERGENCY TECHNICAL 51Technical

Page 54: Emergency Brochure Final LR 20-10-10

52 Technical

Pierlite emergency luminaires have captured the essence of design presence and continuity, satisfying the designer’s needs and the installer’s installation criteria. Meeting with compliance to IEC60598-2-22 enables the design of emergency lighting units to be more flexible. EMCElectromagnetic Compatibility (EMC) under the opus of AS/NZS4051:1998 deals with devices such as lighting/emergency lighting products that may have the potential to cause interference to radio communication systems. This may be mains disturbance (noise down the line), radiation (giving out interfering frequencies from components) or deceptability (interference of frequency due to external noise).Under AS/NZS4051:1998 lighting/emergency lighting products must comply with disturbance levels between 9 KHz and 30 MHz. All Pierlite lighting/emergency lighting products comply with the above standard. EMERGENCY EVACUATION LIGHTING FOR BUILDINGS - AS/NZS2293.1Spacing of emegency luminaires in AustraliaSpacing of emergency luminaires are based on illuminance calculations where the light reaches the floor directly from the emergency light source. Minimum illuminance level for emergency lighting is 0.2 lux.

Pierlite Emergency LightingPlease use classification tables provided with each product.ie: DB136MEmergency ClassificationC0 - D40 C90 - C40 C180 - n/a

Spacing of emegency luminaires in New ZealandSpacing of emergency luminaires is based on light that reaches the floor by reflection from the surfaces of the room, ie: ceiling and walls. Therefore you are required to obtain the utilisation factor of the required luminaire and then calculate the amount of emergency luminaires needed. Minimum illuminance level for emergency lighting is 1 lux.

Formula for spacing of emergency luminaires in New Zealand is:LC(NZ) = LC(AUST) 6 - (6.6 x UF) LC(AUST) - Classification of emergency luminaire to Australian standard. ie: DB136M

Emergency ClassificationC0 - D40 C90 - C40 C180 - n/aLC(NZ) - Classification of the above luminaire modified by the (UF) factor of the area to be illuminated.UF - Determines the proportion of light output from a lamp that falls on a particular area for emergency lighting.

Required Calculation

RI (Room Index) = Length x Width Height (Length + Width)ie: RI (0.95) = 10 x 4 3 (10 + 4)From Room Index locate UF Factor from chosen fitting, ie. 0.42LC(NZ) = D40 = D12.4 6 - (6.6 x 0.42)Move to the nearest higher classification which would be D12.5. Refer to Pages 422 and 425 of the Technical Section for luminaire spacing tables.Note: If the Utilisation Factor for the room is greater than 0.75, the New Zealand formula does not apply. Apply the Australian table classifications only. If the Utilisation Factor for the room is less than 0.15, the value of 0.15 shall apply and be used in the New Zealand formula.

Page 55: Emergency Brochure Final LR 20-10-10

53Technical

Particular requirements – luminaires for emergency lighting. The new terminology recognises that the term ‘emergency lighting’ includes four categories of lighting, each incorporating an alternative energy supply, as follows:• emergencyescapelighting• illuminatedemergencyexitsigns• highrisktaskarealighting• standbylightingHowever as reflected in the new series title, only two of these four categories are addressed in the AS2293 standards –namely emergency escape lighting and illuminated emergency exit signs.PictogramsThe new standards allow only the following pictograms from the international standard document ISO3864-1:

Straight On From Here Left From Here Right From Here

Size Of Pictorial ElementsMinimum pictorial element height for all illuminated exit signage is 100mm.There is no limit on the maximum pictorial element height. The four recommended pictorial element heights of 100, 150, 200 and 250mm correspond to maximum viewing distances as follows.

The Emergency Lighting Working Group, a working group of Lighting Council Australia, provides the following advice regarding changes to emergency lighting standards in Australia.The following new emergency lighting standards are now published:AS2293.1:2005 System design, installation and operationAS2293.3: 2005 Emergency escape luminaires and exit signsThese standards replaced: AS/NZS2293.1:1998 and AS/NZS2293.3:1995Significant changes from AS/NZS2293.1:1998 include:• replacementofword‘exit’withpictogram• inclusionofdetailedrestrictionsonuseofarrows• revisionofmaximumviewingdistancesforexit signs• adoptionofterminologyfromIEC60598.2.22• unlikethe1998version,thisstandardisnot a joint Australian/New Zealand document; there is no content specific to New ZealandThe principal reason for the AS/NZS2293.3:1995 edition of the standard is to specify requirements for exit signs employing internationally accepted pictograms, instead of the previously used word ‘Exit’. Terminology used to describe the subject matter has been modified in both standards to be compatible with that used in IEC60598.2.22 Luminaires Part 2.22

New Standard RequirementsElement Height (mm) Maximum Viewing Distance (m) ≥100 <150 16 ≥150 <200 24 ≥200 <250 32 ≥250 -- 40The maximum viewing distance must be marked on the face of each diffuser located on the background, either within one of the elements or on additional background.Australian Building Code PositionThe Australian Building Codes Board recognised the new emergency lighting standards as at 1st May 2006. The new standards may be utilised on a project by project basis, if approved for the project by the applicable local authority.

Modes of OperationTerminology used to describe the Models) of operation has been modified to include luminaires with multiple emergency lamp configurations. Please refer to the table opposite.

Page 56: Emergency Brochure Final LR 20-10-10

54 Technical

Recommended Locations

Exit DoorsLocate emergency exit luminaire at each exit door. Exit signs shall be mounted at between 2m and 2.7m above floor level, or immediately above the door if higher than 2.7mEnsure the exit does not exceed maximum viewing distances recommended.Check emergency escape route is clear of obstacles and that the minimum illuminance level of 0.2 lux is achieved.Intersecting CorridorsAn emergency luminaire is to be installed within 2 meters of the intersecting corridors.Change in DirectionAn emergency luminaire is to be installed within 2 meters of an intersection at the change of direction except when the change of direction does not have interference of the wall of the corridor and that the C0/C90 spacing is not exceeded.Change in Floor LevelAn emergency luminaire is to be installed at each change of floor level, on the low side.StairwaysProvide emergency luminaires to ensure that each flight of stairs including the intermediate landing receives direct light. A minimum of 1 lux is required.Note: If the intermediate landing in an enclosed stairwell is no longer than 2m in length that intermediate landing need not receive direct lighting.

EscalatorsEmergency lighting is required for escalators to enable users to get off them safely.Toilets(Not referred to in standard but highly recommended)Toilets incorporating 2 or more cubicles or exceeding an area of 8m2 require emergency lighting. Emergency lighting is also to be incorporated into handicapped toilet facilities.Switch RoomsPlace emergency lighting in control, plant or switch rooms that have the provision to

NOTE: This example emergency lighting layout has been created in the intended spirit of AS2293 and should be used as a guide only.

provide normal and emergency lighting to the premises.Covered Car ParksAre treated as part of the normal emergency lighting design and full consideration of exit and emergency lighting is taken into account.

Page 57: Emergency Brochure Final LR 20-10-10

55Technical

Powerpack Suitability & Performance Guide2 Hour Duration Use Code to Choose Correct Power Pack for Emergency Tube/Lamp

Unit Description CodeBILW2/18/6E Inverter 18W 7.2V CBILW2/36/6E Inverter 36W 7.2V DBILW2/58/6E Inverter 58W 7.2V EBILW2/36/8E Inverter 36W 9.6V FNote: ‘E’ Signifies inverter operates on both standard & electronic ballasts

% Ballast Lumen FactorBase Lamp A B C D E FT8 18W 19 47 32 T8 30W 12 20T8 36W 12 25 50T8 58W 8 172G11 PL18 13 47 222G11 PL24 18 302G11 PL36 16 27G24Q PLC13 27 45G24Q PLC18 30 50G24Q PLC36 24 40GR10Q 2D10W 27 45GR10Q 2D21W 25 42GR10Q 2D28W 19 322G10 DF18 14 232G10 DF24 14 232G0 DF36 16 7

Battery Pack to Suit Nickel Cadmium Fixing CentrePart Description Inverter Size Fixing BP4S 4 cell pack 4.8V stick format 282x36 BILW/4’E’Series 173x38x31 166BP6S2 6 cell pack 7.2V 3+3 format 218x36x2 BILW/6’E’Series 173x38x38 166BP8S2 8 cell pack 9.6V 4+4 format 282x36x2 BILW/8’E’Series 173x38x38 166

Battery Pack to Suit Nickel Metal HydridePart DescriptionP4S6 4 cell pack 4.8V block format 187x38x21P6S6 6 cell pack 7.2V block format 252x38x21P8S6 8 cell pack 9.6V block format 320x38x21

2 Hour Duration - T5 Use Code to Choose Correct Power Pack for Emergency Tube/Lamp

Unit Description CodeBILWT5/2/14/6 Inverter 14W T5 7.2V GBILWT5/2/28/8 Inverter 28W T5 9.6V HBILWT5/2/35/8 Inverter 35W T5 9.6V IBILWT5/2/49/8 Inverter 49W T5 9.6V JBILWT5/2/54/8 Inverter 54W T5 9.6V K

% Ballast Lumen FactorBase Lamp G H I J KT5 14W 51 T5 28W 37T5 35W 29 T5 49W 22T5 54W 21

T5 Lamp GuideLamp Type Watts Length Initial Lumens Rated LifeT5 14W 550 1350 16000Linear 28W 1150 2900 16000Fluorescent 35W 1450 3650 16000 49W 1450 4300 16000 54W 1150 5000 16000

Battery Pack to Suit Nickel CadmiumPart Description Inverter Size Fixing CentreBP6S2 6 cell pack 7.2V 3+3 format 218x36x2 BILT5 Series 173x38x38 166BP8S2 8 cell pack 9.6V 4+4 format 282x36x2 BILT5 Series 173x38x38 166

Battery Pack to Suit Nickel Metal HydridePart DescriptionP6S6 6 cell pack 7.2V block format 252x38x21P8S6 8 cell pack 9.6V block format 320x38x21

55Technical

Page 58: Emergency Brochure Final LR 20-10-10

56 Technical

Information & Wiring Guidelines for Powerpacks & InvertersPlease read these instructions carefully before installing or maintaining this equipment. This data should be used as a guide only. Good electrical practices should be followed at all times.Recommended Installation /Maintenance GuidelinesThe installer is responsible for all relevant safety and building code standards.Do Not Megga After InstallationIt is recommended to disconnect live and neutral wires from the unit before an insulation resistance check.Converting An Existing LuminaireInstalling a Power Pack will usually void the manufacturer’s warranty and EMC compliance. It is the installer’s responsibility to comply with relevant wiring, EMC and emergency lighting requirements in accordance with the relevant sections of AS2293 which may include the necessity to have the luminaire tested and certified both thermally and photometrically. Power Packs normally installed inside the luminaire may require the repositioning of components in the luminaire, ie. starter, ballast, capacitor. Any of the components being utilised that now show signs of end of life should be replaced at the time of converting the power pack. It is also advised that the internal wiring be replaced using the recommended high temperature cable (V90) minimum.Use Of Remote EnclosuresThermal conditions and/or lack of space in the luminaire may result in remote mounting

of the power pack in an appropriate remote enclosure. Ensure the following is taken into account:-Ensure test switch is accessible during re-lamping. It may be mounted within the luminaire or remote enclosure.LED is to be visible during normal operation irrespective of mounting within the luminaire or remote enclosure.Connecting cables to the enclosure are not to exceed 1 metre.Resistance of the battery wires are not to exceed 0.5ohms.Ensure battery leads are kept as short as possible.Testing The Conversion Of the LuminaireConfirm its electrical safety and its operation.Confirm the temperature of main components utilised in the luminaire comply with recommended requirements.The luminaire should be mounted as intended. The ambient temperature is to be as expected for the luminaire’s intended environment.Apply maximum voltage prescribed for a period of 24 hours, then switch off the luminaire and ensure that it provides appropriate emergency duration in accordance with relevant standards.Examine temperature of relevant components. If components comply with the prescribed temperature, then the balance of the luminaire may be converted the same way.

NoteBILW Power Packs incorporate a thermistor to protect componentry from overheating in excessive temperatures. Once tripped it may only be reset by switching off the mains. Once stable conditions are achieved, reconnect mains. Pierlite emergency luminaires have Ta Ratings from Ta30 to Ta40.When installing a BILW power pad feed the supply cable through the appropriate cable entry. Avoid obstruction to mounting holes, other lighting componentry and covers.It is recommended that a full duration test is carried out prior to commissioning. Upon appropriate connection, initially charge the luminaire for a minimum of 24 hours. Upon charging, the red LED will light indicating that mains is present and batteries are charging.After 24 hours disconnect the supply and check for the rated duration period. Pressing the test button carries out a quick confidence test.Routine tests should be carried out in accordance with the relevant Standards, with all results and status recorded in a log book.Batteries are to be replaced with the same Pierlite battery pack. The model number is stamped on the battery pack. When disposing of batteries do not pierce, incinerate or short circuit. Batteries should be disposed of in accordance with recognised disposal methods.Powerpacks and inverters are designed to operate on 230V AC 50/60Hz

Page 59: Emergency Brochure Final LR 20-10-10

57Technical

Mains & Lamp Connection DiagramsFor the standard fluorescent Exit range.

Maintained and Non-Maintaned Sustained

Page 60: Emergency Brochure Final LR 20-10-10

58 Technical

Wiring Diagrams for Standard - Electronic BallastsThe wiring diagrams are given as a guide to installation with electronic ballasts. Due to the wide variety of electronic ballast units and connection styles available, it is advisable that the luminaire be fully tested to prove its correct functionality.

NOTEFor Non-Maintained use1 Delete ballasts & starter2 Only connect Pin 1 & Pin 3 lamp3 Connecting neutral to lamp will improve striking4 For further technical data visit www.pierlite.com

NOTE1 Do not flash test2 All connections shall be made with at least V90 rated solid core 0.5mm wire

Page 61: Emergency Brochure Final LR 20-10-10

EMERGENCY FAULT FINDING FLOW CHART

NO NO

NO NO

Fails Fails

YES YES

YES YES

OK OK

EXITOK

LED lamp’s Off Lamp Off

Check LED strip & batteries are pluged

into PCA board

Check the power is on and connected to a non switched

circuit. Then retest

Check the power is on and connected to a non switched

circuit. Then retest

Check battery connected

Check battery connected

Has battery been charged for 16hrs

Has battery been charged for 16hrs

Charge battery for 16hrs

Charge battery for 16hrs

Co-ordinate resolution with QA

Co-ordinate resolution with QA

Co-ordinate resolution with QA

Co-ordinate resolution with QA

Battery ok for 90min

Battery ok for 90minTEST TEST

Fail 90min test Fail 90min test

Replace battery Replace battery

Return inverter with PFR to QA

Return inverter with PFR to QA

Return with PFR to QA

Return with PFR to QA

and/or and/or

Fail FailPass Pass

Check LED Inverter lamp

is On

Check LED Inverter lamp

is On

EXIT

BDM Emergency Lighting - David Virgona 0408 181 404 Version 1 : 30.03.09

LED 10W

YES YES

Check lamp is functioning

Replace faulty lamp

EMERGENCY FAULT FINDING FLOW CHART

NO

NO

NO

Fails

YES

YES

YES

OK

BATTENOK

Lamps Off

Check both lamps are

functioning

Check the power is on and connected to a non switched

circuit. Then retest

Check battery connected

Put in Emergency Mode

Has battery been charged for 16hrs

Charge battery for 16hrs

Co-ordinate resolution with QA

Co-ordinate resolution with QA

Battery ok for 90minTEST

Fail 90min test

Replace battery

Return inverter with PFR to QA

Return with PFR to QA

and/or

Replace faulty lamp

Fail Pass

Check LED Inverter lamp

is On

BATTEN

BDM Emergency Lighting - David Virgona 0408 181 404 Version 1 : 30.03.09

59Technical

Page 62: Emergency Brochure Final LR 20-10-10

GUIDE TO SAFE HANDLING OF LIGHTING PRODUCTS CONTAINING BATTERY SYSTEMS.

Introduction:Battery systems are an essential component in a number of lighting products, especially emergency lighting systems, which require an alternative energy source when the traditional mains supply source fails.

Handling and maintenance procedures for lighting battery circuits is no different to handling conventional battery components ie: scheduled maintenance is an essential process in maintaining the components service life and disposal of the components at the end of the service should be conducted in a safe and environmentally responsible manner.

The following information serves as a guide to safe handling and maintenance of Pierlite Lighting products containing battery components.

• Battery performance should be checked on a regular schedule and components replaced when the performance falls below the manufacturer’s specification.

• Failed components should be disposed of in accordance with local waste management requirements.

• In the instance of a catastrophic failure resulting in a ruptured battery casing, the component should be handled with extreme care, avoiding contact with the installer’s skin, eye or inhalation. Suitable protective clothing is recommended for such maintenance procedures.

• The components and contaminated protective clothing should then be disposed of in accordance with your local waste management requirements.

• If skin or clothing comes in contact with fluid from a Nickel Cadmium (NiCad) or Nickel Metal (NiMH) battery, thoroughly wash the area immediately with clean water and seek medical care where needed.

The sun and the moon, two dominant sources of light control.The third is Pierlite.

60 Technical

Page 63: Emergency Brochure Final LR 20-10-10

The sun and the moon, two dominant sources of light control.The third is Pierlite.

Pierlite is a member of the Gerard Lighting Group.

Page 64: Emergency Brochure Final LR 20-10-10

Pierlite is a member of the Gerard Lighting Group.

Issue: October 2010

Product region: Australia

© 2010 Pierlite Australia and acknowledgements where noted. www.pierlite.com