enclosed circuit breakers - dle electric supplydlelectricsupply.com/files/e1scpd63b140.pdf ·...

6
Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers Siemens Enclosed Circuit Breaker Complete Assemblies consist of a thermal magnetic molded case circuit breaker frame, trip unit, enclosure and standard line and load pressure wire connectors assembled and shipped as one unit from the Siemens modification center. For service equipment or applications Catalog Numbering requiring a solid neutral, neutrals must be priced and ordered separately except as noted. To order, select the appropriate prefix from the table below and place it in front of the desired non-interchangeable trip or interchangeable trip circuit breaker catalog SELECTION number. For circuit breaker selection, refer to pages 72 thru 89. Note: Lead times are determined based on availability of components. Shaded items in this section may contain components that are not normally stocked. Prefix E1S E1F E3R E12 E4X Enclosure Type Type 1 Surface Type 1 Flush Type 3R Type 12 Type 4X Stainless Steel Example: Catalog number E1SJD63B400 consists of: (1) JD63F400 frame (1) JD63T400 trip unit (1) J6N1 enclosure (6) TA2J6500 wire connectors ii o p = 5 1 rr. S3 m > § 31 CO Selection And Pricing By Enclosure Type Circuit Breaker Breaker Frame QJ2 QJH2 QJ2-H ED2 ED4 ED6 Number of Poles 2 3 2 3 2 3 2 2 3 3 2 2 2 3 3 3 2 2 2 3 3 3 Ampere Rating 60-225 60-225 60-225 60-225 60-225 60-225 15-60 70-100 15-60 70-100 15-60 70-100 110-125 15-60 70-100 110-125 15-60 70-100 110-125 15-60 70-100 110-125 List Price S — Complete Assembly Typel Surface or Flush 470.00 1009.00 933.00 1354.00 1126.00 1680.00 343.00 486.00 453.00 597.00 526.00 654.00 1297.00 652.00 747.00 1460.00 597.00 723.00 1382.00 727.00 880.00 1678.00 Type 3R 591.00 1155.00 1054.00 1500.00 1247.00 1826.00 547.00 690.00 657.00 801.00 730.00 858.00 1654.00 856.00 951.00 1817.00 801.00 927.00 1739.00 931.00 1084.00 2035.00 Type 12 NA NA NA NA NA NA 425.00 568.00 535.00 679.00 608.00 736.00 1438.00 734.00 829.00 1601.00 679.00 805.00 1523.00 809.00 962.00 1801.00 Type 4, 4X NA NA NA NA NA NA 2453.00 2596.00 2563.00 2707.00 2636.00 2764.00 3313.00 2762.00 2857.00 3476.00 2707.00 2833.00 3398.00 2837.00 2990.00 3694.00 Lug Catalog Number (included) TA1Q300 TA1Q300 TA1Q300 15-25A SA1E025 30-60A LineLNIElOO LoadLD1E060 70-100 LN1E100 110-125A TA1E6125 Neutrals Catalog Number List Price S Included with enclosure Catalog Number W53045 included with enclosure Discount Schedule F Siemens Electrical Products SPEEDFAX 2000

Upload: hatram

Post on 19-Feb-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

Enclosed Circuit Breakers

Complete Assemblies—Molded Case Circuit BreakersSiemens Enclosed Circuit BreakerComplete Assemblies consist of a thermalmagnetic molded case circuit breakerframe, trip unit, enclosure and standardline and load pressure wire connectors —assembled and shipped as one unit fromthe Siemens modification center. Forservice equipment or applications

Catalog Numbering

requiring a solid neutral, neutrals must bepriced and ordered separately except asnoted.To order, select the appropriate prefixfrom the table below and place it in frontof the desired non-interchangeable trip orinterchangeable trip circuit breaker catalog

SELECTION

number. For circuit breaker selection, referto pages 72 thru 89.Note: Lead times are determined based

on availability of components.Shaded items in this section maycontain components that are notnormally stocked.

Prefix

E1S

E1F

E3R

E12

E4X

Enclosure Type

Type 1 Surface

Type 1 Flush

Type 3R

Type 12

Type 4X Stainless Steel

Example: Catalog number E1SJD63B400 consists of:

(1) JD63F400 frame(1) JD63T400 trip unit(1) J6N1 enclosure(6) TA2J6500 wire connectors

iio p= 5— 1 rr.

S3m>

§31CO

Selection And Pricing By Enclosure TypeCircuit Breaker

BreakerFrame

QJ2

QJH2

QJ2-H

ED2

ED4

ED6

NumberofPoles

2

3

2

3

2

3

22

33

222

333

222

333

AmpereRating

60-225

60-225

60-225

60-225

60-225

60-225

15-6070-100

15-6070-100

15-6070-100

110-125

15-6070-100

110-125

15-6070-100

110-125

15-6070-100

110-125

List Price S — Complete Assembly

TypelSurfaceorFlush

470.00

1009.00

933.00

1354.00

1126.00

1680.00

343.00486.00

453.00597.00

526.00654.00

1297.00

652.00747.00

1460.00

597.00723.00

1382.00

727.00880.00

1678.00

Type3R

591.00

1155.00

1054.00

1500.00

1247.00

1826.00

547.00690.00

657.00801.00

730.00858.00

1654.00

856.00951.00

1817.00

801.00927.00

1739.00

931.001084.002035.00

Type12

NA

NA

NA

NA

NA

NA

425.00568.00

535.00679.00

608.00736.00

1438.00

734.00829.00

1601.00

679.00805.00

1523.00

809.00962.00

1801.00

Type4, 4X

NA

NA

NA

NA

NA

NA

2453.002596.00

2563.002707.00

2636.002764.003313.00

2762.002857.003476.00

2707.002833.003398.00

2837.002990.003694.00

LugCatalogNumber(included)

TA1Q300

TA1Q300

TA1Q300

15-25ASA1E025

30-60ALineLNIElOOLoadLD1E060

70-100LN1E100

110-125ATA1E6125

Neutrals

CatalogNumber

ListPrice S

Included withenclosure

Catalog NumberW53045included withenclosure

Discount Schedule F Siemens Electrical Products SPEEDFAX 2000

Page 2: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

Enclosed Circuit Breakers••••••••HiEnclosure Types

GENERAL

Q £LU *"

35i*uo

Type 1

% >|)

Types 7, 9 '*"!

Type 3R

Types 5, 12, 12K

Type 1 — A general indoor, sheet-steelenclosure for use in normalatmospheres. Listed as serviceentrance equipment.Type 3R — An outdoor, sheet-steelenclosure providing protection againstdriving rain, sleet or snow. Listed asservice entrance equipmentTypes 7,9 — Cast aluminum enclosureclassified for explosion and fire hazard.

Only enclosure for use in hazardouslocation. Class I; Group D-Class II;Groups E, F, and G-Class III.

Types 4,4X (not shown) — Stainlesssteel indoor or outdoor enclosuredesigned for use in areas where seriouscorrosion problems exist. They provide adegree of protection against windblowndust, rain, splashing water and hose-directed water. Meets NEMA Type 3, 4,

4X, 12 and 13 requirements and UL 508Type 4 and 4X requirements.

Types 5,12 — A special-industry, sheet-steel enclosure for use in atmospherescontaining particles of lint, dust, dirt,sawdust and other foreign matter.Type 12K — A semi-dusttight sheet-steel enclosure. Listed as serviceentrance equipment.

Siemens Electrical Products SPEEDFAX 2000

Page 3: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

Enclosed Circuit Breakers

Enclosures — Type 1SELECTION/DIMENSIONS

Dimensions

F

j

-

\

rM4? — --f

0

1-4<• B ••

r

i

rM

~ ~"~~~ "

i— i-

i

i —

j

Figure 1

T

A

-

h<— B — i I*C*

IP

i DJ u ,

P5^

7o:

_J.'̂ ::

1 K-E -*NF G

:

D

p=^3_H

1 '&<>&•_ j

Figure 2

i

p

\

B 1 f-C-»ipr: ^

"B"

i ^..

_

t

i — *

)

Figure 3

Typel

Fig.No.

1

1

1

2

2

2

3

3

3

3

BreakerFrame

OP, QPH,HOP

QP, QPH,HOP

BQ, BQH,HBQ

ED2, ED4, ED6,HED4, HED6, HHED6

ED4, ED6, HED4, HED6,HHED6, CED6

FXD6, FD6, FXD6,FD6, HFD6, HFXD6,HHFD6, CFD6

JXD2, JD6,JXD6, HJD6,HJXD6, HHJD6,HHJXD6, SJD6,SHJD6, SXD6H

LD6, LXD6,HLD6, HLXD6,HHLD6, HHLXD6,SLD6, SHLD6,SCJD6, SCLD6, LXD6H

LMXD6, LMD6,HLMXD6, HLMD6

MD6, MXD6, SMD6,HMD6, HMXD6,SHMD6, ND6, NXD6,SND6, HND6, HNXD6,SHND6, CMD6,SCMD6, CND6, SCND6

PD6, PXD6, HPD6,HPXD6, CPD6, RD6,SPD6, SHPD6, RXD6,HRD6, HRXD6

NumberofPoles

1-2

3

3

2-3

2-3

2-3

2-3

2-3

2-3

2-3

3

MaximumCurrentRating

4060

125

100

100

100

125

250

400

600

800

1200

2000

CatalogNumber

E0204ML1040S®®®E0204ML1060S®®®E0202ML1125S®®®

E0303ML3100S®®®

EB3100S®®

E2N1S®E2N1F®

CED6N1S®®CED6N1F®®

F6N1S®F6N1F®

J6N1®

LD6N1®

LMD1®

MMD61

PRD6N1

ListPrice $®

CSO®47.00®74.00®

120.00

120.00®

117.00117.00

211.00211.00

144.00

203.00

352.00

703.00

703.00

4956.00

WeightLb./Ship.Package

161630

8

32

88

1414

33

120

101

132

132

Dimensions (inches)

A

1%Th

17!4

17«

m

16%178

21%22%

38%

41%,

46

60

60

90

B

-J U

l (J

las

si

SK

Tk

TA

7548%

7%8/

1 1 "A,

22%

22%

22%

22%

32

C

3%3'AW

v&

43/.

5'/6

5'A

5'A5%>

5'A

10'%.

10%

10

10

28

D

53/.m

14^

14J«

14»

13'5i,13«5<4

18X18X

33

37

42

55J4

551/,,

E

33/4

33/.4)4

VA

Vk

5%5Y,

5V,5%

8

18%

18X

^8Y,

18%

F

1X.VA>1

5/6

15A

1S/6

1

1

1

1

1%

2%.

2BX.

2%.

2%,

K.O. Dimensions

6 Pics.

G

X 1X,1%13/., 2

1'4 1X13X, 2,2^,3

2 Pics.

H

X 1X1XIX 2

n, ^%,13/., 20,2)^,3

For inches / millimeters conversion,see Application Data section.CSO - Consult Sales Office for pricing©Surface mounted, indoor. If flush mounting is required,

replace suffix "S" in catalog number with suffix "F".Also, if outdoor model required, use prefix "W"instead of "E".

©Discount Schedule B.

©Does not include circuit breaker. Order circuitbreaker separately.

©Neutral not included. Order as separate item from tableon next page.

©Neutral included in enclosure.©Surface mounted, indoor. If outdoor model is required,

use prefix "W" instead of "E". Not available in flush("F") model.

©Use for 110-125 ampere ED4, ED6, HED4 or HED6circuit breakers.

©Will not accept breaker with shunt trip.©Will not accept 2-pole GFCI or breaker with shunt trip.

Built to order. Consult sales office for factory lead timeand prices.

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule F

Page 4: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

Molded Case Circuit Breakers

Reference GuideSELECTION /APPLICATION

MCI i i iai iviayiiouvj nip Ljitjaixcio

Page

RatingsAC

DC

Dimensions ininches

OvercurrentDevices

Accessories &Modifications

IndividualEnclosures

Poles

Amperes, Continuous

Volts 50/60 HZ

Interrupt RatingSymmetrical RMSAmperes

3-Pole

240V

UL 480V

600V

leu??n/?in\/Ics

'EC 947-2 leu50/60HZ Ics

500V 'CU

-°°X Ics2-Pole 250V DC Interrupting Ratings

3-Pole, 500V DC Interrupting Ratings®

Circuit breakers recmounting block. Diare for circuit break

uire Connect-all Heightmensions shown Widther only. Depth

Thermal and Adjustable Magnetic Trip

Molded Case Switch

UndervoltageTrip

Shunt Trip

Auxiliary Switch

Alarm Switch

Mechanical Interlock

Electric Motor Operator

Fungus Proofing (ref. page 106)

Mounting Block (required)

Type 1 — Indoor Surface

Type 1 — Indoor, Flush

Type 3R — Outdoor-Rainproof

Type 7 — Flammable Gas Atmosphere

Type 9 — Combustion Dusttight

Type 5, 12 — Lint, Fine Dust, Oils, Coolants

Type 12K — Semi-Dusttight

General Purpose Breakers

PD6®,PXD6®

883

1200-1600

600

65,000

50,000

25,000

65,000

33,000

40,000

10,000

30,000

8,000

30,000

25,000

16.00

9.00

6.19

I

I

iy

•1

i

I

i

V

Iy——————

HPD6®,HPXD6®

88

3

1200-1600

600

100,000

65,000

50,000

100,000

50,000

65,000

17,000

42,000

21,000

30,000

50,000

16.00

9.00

6.19

J—1

J

y

J

J

J

J

•1

y——————

CPD6®

88

3

1200-1600

600

200,000

100,000

65,000

200,000

100,000

100,000

25,000

65,000

17,000

30,000

50,000

16.00

9.00

6.19

J—

J

yyyyyyyt

——————

RD6®,RXD6®

89

3

1600-2000

600

65,000

50,000

25,000

65,000

33,000

40,000

10,000

30,000

8,000

30,000

25,000

16.00

9.00

6.19

y/yyyyyyyyy——————

HRD6®,HRXD63>

89

3

1600-2000

600

100,000

65,000

50,000

100,000

50,000

65,000

17,000

42,000

21,000

30,000

50,000

16.00

9.00

6.19

y—yyyyyyyyy——————

For inches / millimeters conversion, see Application Data section.

fflFor DC UPS application.©Requires Connect-all mounting assembly. Dimensions

shown are for circuit breaker only.

Siemens Electrical Products SPEEDFAX 2000

Page 5: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

Molded Case Circuit Breakers

PD 1600A Frame Sentron SeriesType PXD6©Non-Interchangeable Trip3-Pole 600V AC, 250-500V DC© Blue Label

ContinuousCurrent Rating40-C

12001400

1600

Complete Breaker Assembled(Frame/Trip Unit Only)

Catalog Number

PXD63B120PXD63B140PXD63B160

List Price S

13221.0013221.0013221.00

MountingAssembly

Catalog Number

MB9301-or-

MB9302

List PriceS

963.00

Lugs (6 required)

Catalog Number

TA5P600

List PriceS

250.00.

Type PD6 Interchangeable Trip3-Pole 600V AC, 250-500V DC®

Type HPD6 Interchangeable Trip3-Pole 600V AC, 250-500V DC®

ContinuousCurrentRating 40°C

120014001600

Complete BreakerUnassembled

CatalogNumber

HPD63B120HPD63BHOHPD63B160

ListPriceS

17375.0017375.0017375.00

Frame Only

CatalogNumber

HPD63F160

ListPrice $

8486.00

Trip Unit Only

CatalogNumber

PD63T120PD63T140PD63T160

ListPriceS

6426.006426.006426.00

MountingAssembly

CatalogNumber

MB9301-or-

MB9302

ListPrices

963.00

Lugs |6 required)

CatalogNumber

TA5P600

ListPriceS

250.00

Type CPD6 Non-Interchangeable TripFuseless Current Limiting3-Pole 600V AC, 250-500V DC®

Red Label

Continuous CurrentRating 40°C

120014001600

Complete BreakerAssembled (Frame/Trip Unit Only)Catalog Number List Price $CPD63B120CPD63B140CPD63B160

17535.0017535.0017535.00

SELECTION

Ordering InstructionsComplete Breaker Unassembledwith LugsPrices of PD6, HPD6, RD6, and HRD6type breakers include frame, trip,mounting base (MB9301), and both lineand load lugs (PD Frame - TA5P600,RD Frame - TC5R600). When orderedby these catalog numbers, thecustomer will receive the frame, trip,mounting assembly and lugsseparately packaged. For applicationsrequiring different mounting base orlugs, order individual items as needed.Complete Breaker Assembledwithout LugsPrices of PXD6, HPXD6, RXD6 andHRXD6 type breakers include framewith non-interchangeable trip unitinstalled only. Order requiredmounting base and lugs separately.100% RatedTypes PXD6, ND HPXD6 breakers areavailable with 100% ratings. To orderadd suffix "H" to catalog number, and10% to list price. RD 2000A Frames notavailable with 100% ratings.50°C Applications see page 111.400HZ Applications see pages 111and 147.

Lugs®

CatalogNumberTA5P600TC5R600TC4P750TA6R600

No of CablesperConnector1-5 PCS.1-5 PCS.1-4 PCS.1-6 PCS.

Wire Range300-600 kcmil Cu/AI300-600 kcmil Cu only500-750 kcmil Cu/AI300-600 kcmil Cu/AI

ListPrice $250.00334.00229.00265.00

Mounting Bases for PD & RD13.62

<•> 2r- °.

6.19^* 6.001

MB9301 MBR9302 MB9301 MBR9302 MB9301

© Use two outside poles of a 3-pole circuit breaker for 250V©When wired as shown on page 49, this circuit breaker is

UL listed and rated for use on 500V DC ungrounded UPSsystems only.

<DPXD6, HPXD6 type circuit breakers are UL Listed forreverse feed applications.

® For additional information See Note: A, page 108.

Note: PD frame qualified to UL489 supplement B"NAVAL". See page 111 for additional information.

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule F

Page 6: Enclosed Circuit Breakers - DLE ELECTRIC SUPPLYdlelectricsupply.com/files/E1SCPD63B140.pdf · Enclosed Circuit Breakers Complete Assemblies—Molded Case Circuit Breakers ... Fo r

~

Molded Case Circuit Breakers

RD 2000A Frame Sentron SeriesType RXD6® Blue Label

Non-Interchangeable Trip (Assembled Circuit Breaker Only Without Lugs)

3-Pole 600V AC, 250-500V DC©

ContinuousCurrentRating 40°C

160018002000

Complete BreakerAssembled(Frame/Trip Unit Only)

CatalogNumber

RXD63B160RXD63B180RXD63B200

ListPrice $

17623.0017623.0017623.00

Mounting

Assembly

CatalogNumber

MB9301-or-MB9302

ListPrices

963.00

963.00

Lugs (6 required)

CatalogNumber

TC5R600

ListPrices

334.00

Type RD6 Blue Label

Interchangeable Trip (Unassembled Circuit Breaker with Lugs)

3-Pole 600V AC, 250-500V DC©

ContinuousCurrentRating 40°C

160018002000

Complete BreakerUnassembledwith Lugs

CatalogNumber

RD63B160RD63B180RD63B200

ListPrice S

17623.0017623.0017623.00

Frame Only

CatalogNumber

RD63F200

ListPriceS

7660.00

Trip Unit Only

CatalogNumber

RD63T160RD63T180RD63T200

ListPriceS

6996.006996.006996.00

MountingAssembly

CatalogNumber

MB9301-or-MB9301

ListPriceS

963.00963.00963.00

Lugs (6 required)

CatalogNumber

TC5R600

ListPriceS

334.00

Type HRXD6® Black Label

ContinuousCurrent Rating40°C

160018002000

Complete Breaker Assembled(Frame/Trip Unit Only)

Catalog Number

HRXD63B160HRXD63B180HRXD63B200

List Price $

16477.0016477.0016477.00

Type HRD6 Black Label

ContinuousCurrentRating 40°C

160018002000

Complete BreakerUnassembledwith Lugs

CatalogNumber

HRD63B160HRD63B180HRD63B200

ListPriceS

19445.0019445.0019445.00

Frame Only

CatalogNumber

HRDE3F200

ListPrice S

9482.00

Trip Unit Only

CatalogNumber

RD63T160RD63T180RD63T200

ListPriceS

6996.006996.006996.00

MountingAssembly

CatalogNumber

MB9301-or-MB9302

ListPriceS

963.00

963.00

Lugs (6 required)

CatalogNumber

TC5R600

ListPriceS

334.00

Interrupting Ratings

BreakerType

PD6, PXD6,RD6, RXD6

HPD6, HPXD6HRD6, HRXD6

CPD6

UL 489 A 1R

RMS Symmetrical KA

Volts AC

240

65

100

200

480

50

65

100

600

25

50

65

Volts DC®

250

30 (2P)

30 (2P)

30 (2P)

soo

25 <3P)

50 (3P)

50 (3P)

IEC 947-2

Volts AC (50/60HZ)

220/240 380/415 500

(leu) lies)

65

100

200

33

50

100

(leu) lies)

40

65

100

10

17

25

(leu) (Ics)

30

42

65

8

11

17

Instantaneous Adjustment Trip Range (PD / RD Frames)

Breaker AmpereRating1200-2000

Nominal Instantaneous Values±25%ToleranceLow5000

2

5715

3

64304

7145

5

786068575

7

9790

±20%ToleranceHigh10,000

©Use two outside poles of a 3-pole circuit breaker for 250VDC applications.

©When wired as shown on page 49, this circuit breaker isUL listed and rated for use on 500V DC ungrounded UPSsystems only.

®RXD6 and HRXD6 type circuit breakers are UL Listed forreverse feed applications.

Note: RD frame qualified to UL489 supplement B "NAVAL".See page 111 for additional information.

SELECTION /DIMENSIONS

Mounting BlockCatalogNumber

MB9301MBR9302

ConnectionPoints

FrontRear

ListPrice $

963.00963.00

Shipping WeightsNumber ofPoles

Number perCarton

ShippingWeight (Ibs.)

PXD6, HPX06, RXD6, HRXD6, CPD6Assembled Breakers3 1 61.5

PD6, HPD6, RD6, HRD6Frame Only

3 1 55.0

PD6, RD6Trip Unit Only

3 1 6.5

Mounting AssemblyMB9301MBR9302

1

153.0

50.9

UJ O

siIs

Discount Schedule F Siemens Electrical Products SPEEDFAX 2000