XA04NO028 Entrainment Measurements in Annular Flow A. Assad, C. Jan and M. de Bertodano Purdue Univers ty Thermo-Hydraulics and Reactor Safety Laboratory West Lafayette, IN 47907-1290 and Stephen Beus Bettis Atomic Power Laboratory Westinghouse Electric Corporation West Mifflin, PA 15122-0079 Abstract Airtwater and vapor /freon were utilized to scale and simulate annular two-phase flow for high pressure steam/water conditions A unique vaportliquid Freon loop was built to obtain the high pressure data. The results were compared with two correlations available in the open literature. The Ishii and Mishima dimensionless group was able to scale the data remarkably well even for vaporAiquid Freon. However the correlation needs to be adjusted for high Weber numbers of the gas phase. I Introduction pressure steamtwater data of Keeys et. al. 1970). The droplet entrainment in annular gasAiquid For the first set, the entrainment fraction is below flow is the fraction of the liquid flow that is dispersed 40% and for the second it is above 70%. Therefore in the gas core. The rest flows in a liquid film along there is a gap in the middle. Furthermore whereas the wall. the first set is one of many available in the open There are two widely used techniques to literature, the second is unique. measure the entrainment fraction. One is to .Cousins and Hewitt's 1968) experiments were carried out in adiabatic, upwards, airtwater flows in measure the droplet flow directly using isokinetic tubes at near ambient temperature and low probes. The second is to extract the liquid film pressure, i.e. 0 14 to 024 MPa A 95 mm 3/8 in) through a porous probe or some equivalent I.D. bore acrylic resin tube and a 31.8 mm (1 14 in) arrangement This last technique is probably more I.D. bore copper tube were employed. The tube accurate because it is difficult to obtain a lengths used to attain equilibrium conditions are 22 measurement of the droplet flow near the film : m 717 ft.) for acrylic resin and 98 m 32 ft) for Most of the data available has been obtained in copper, respectively. air/water experiments at atmospheric pressure. The distance necessary to reach an equilibrium However many applications operate under very condition is given by Kataoka and Ishii 1982 as different conditions. For the case of high pressure follows; steam boilers the density ratio and the surface tension are quite different from these experiments. The available correlations must rely on these Z = 440D W" Re" (1) f data and therefore there is some uncertainty when where, they are applied to other situations. The present 'D 1/3 experiments employ airtwater and Freon-113 data We, a' pj, (2) with the objective to bridge this gap in experimental a Ps data. and 2 Previous work Re. o,,jf D (3) ,U.f 2.1 Available data. We have selected two representative data sets For Cousins and Hewitt's experiments, the value from the open literature, The low pressure airtwater of 440 We,0.25/ Ref0_5 lies between 50 and 150, data of Cousins and Hewitt 1968) and the high 447

Upload: others

Post on 19-Mar-2022

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Entrainment Measurements in Annular Flow

XA04NO028

Entrainment Measurements in Annular Flow

A. Assad, C. Jan and M. de Bertodano

Purdue Univers tyThermo-Hydraulics and Reactor Safety Laboratory

West Lafayette, IN 47907-1290and

Stephen Beus

Bettis Atomic Power LaboratoryWestinghouse Electric Corporation

West Mifflin, PA 15122-0079

AbstractAirtwater and vapor /freon were utilized to scale and simulate annular two-phase flow

for high pressure steam/water conditions A unique vaportliquid Freon loop was built toobtain the high pressure data. The results were compared with two correlations available inthe open literature. The Ishii and Mishima dimensionless group was able to scale the dataremarkably well even for vaporAiquid Freon. However the correlation needs to be adjustedfor high Weber numbers of the gas phase.

I Introduction pressure steamtwater data of Keeys et. al. 1970).The droplet entrainment in annular gasAiquid For the first set, the entrainment fraction is below

flow is the fraction of the liquid flow that is dispersed 40% and for the second it is above 70%. Thereforein the gas core. The rest flows in a liquid film along there is a gap in the middle. Furthermore whereasthe wall. the first set is one of many available in the open

There are two widely used techniques to literature, the second is unique.measure the entrainment fraction. One is to .Cousins and Hewitt's 1968) experiments were

carried out in adiabatic, upwards, airtwater flows inmeasure the droplet flow directly using isokinetic tubes at near ambient temperature and lowprobes. The second is to extract the liquid film pressure, i.e. 0 14 to 024 MPa A 95 mm 3/8 in)through a porous probe or some equivalent I.D. bore acrylic resin tube and a 31.8 mm (1 14 in)arrangement This last technique is probably more I.D. bore copper tube were employed. The tubeaccurate because it is difficult to obtain a lengths used to attain equilibrium conditions are 22measurement of the droplet flow near the film : m 717 ft.) for acrylic resin and 98 m 32 ft) for

Most of the data available has been obtained in copper, respectively.air/water experiments at atmospheric pressure. The distance necessary to reach an equilibriumHowever many applications operate under very condition is given by Kataoka and Ishii 1982 asdifferent conditions. For the case of high pressure follows;steam boilers the density ratio and the surfacetension are quite different from these experiments.

The available correlations must rely on these Z = 440D W" Re" (1)fdata and therefore there is some uncertainty when where,they are applied to other situations. The present 'D 1/3

experiments employ airtwater and Freon-113 data We, a' pj, (2)with the objective to bridge this gap in experimental a Psdata. and

2 Previous work Re. o,,jf D (3),U.f

2.1 Available data.We have selected two representative data sets For Cousins and Hewitt's experiments, the value

from the open literature, The low pressure airtwater of 440 We,0.25/ Ref0_5 lies between 50 and 150,data of Cousins and Hewitt 1968) and the high

447

Page 2: Entrainment Measurements in Annular Flow

Hence, the entrainment fractions measured at the This correlation indicates that the equilibriumtube exit can be regarded as the equilibrium value, entrainment fraction E. depends on the total liquidsince ZD is greater than 230 at this point for all Reynolds and gas Weber numbers.cases. Dallman et al. 1979) correlated the entrainment

As shown in Figure 1, the injected liquid film was rate from a liquid film as�removed by suction through a porous wall section(S1) and the liquid film formed by redepositingdroplets was removed by suction through porous WU W LFC, U 2

wall (S2). The flow rate of entrained liquid (WLE)1, P 9 f (6)

was determined by a mass balance equation:

where kA is an entrainment coefficient, P is the

W = WLA + (W,,), (4) perimeter of the wetted surface and WFC is thecritical liquid mass flow rate required for the onset ofentrainment. For air/water upflow kA= 35 x 1,6Here, WL is the inlet liquid flow rate, WILF) IS

the liquid film removal rate though porous wall sec2 /kg and WC/P= 0046 kg/m s.section (S1). The deposition rate is represented in terms of

The importance of this experiment is that the the concentration of droplets in the gas core, C, anddeposition rate is also measured with the second the deposition coefficient, kD (m/sec), as:suction probe. Various deposition lengths weremeasured.

Keeys et al. 1970), measured the liquid k,,C = k, (7)entrainment in adiabatic annular stearntwater flows PK;at high pressures 3.447 and 6894 MPa). The 12.6mm I.D. test section was 366 m long. The value of At steady state, the rate of deposition from the440 WeI0-25/ RefP-s lies between 1 0 to 27 and ZD is gas core is equal to the entrainment rate from the290. This ensures equilibrium conditions at the liquid film, ie.,liquid film etraction point. As shown in Figure 2 theliquid film flow rate is measured by extracting the (8)film through a film removal device at the end of thetest section. The steam, which is inevitably removedwith the liquid film, is passed into a trace-heated Inserting equations 6) and 7) into equation (8),cylinder and pumped back through another orifice Dallman obtained:'02'. When the pressure difference across orifice'02' is increased, the liquid film removal rate k.4 01, WeDincreases until a plateau is reached. The true liquid E = _4k D

film flow rate was taken as this value. E 0-I WeD (9)

2.2 Available correlations 4kD

Several correlations have been developed. where we have defined-Some of these orrelations have been reviewed byIshii and Mishima 1989). Two representativecorrelations are shown below: Dalman et al. 1979) pj','D fp, W

PCWeD and E., I - L�! (10)and Ishii and Mishima (11 989). a P, WIIshii and Mishima 1989) proposed a detailed

correl ation on the basis of an entrainment inceptoncriterion and a force balance at the wavy interface Since equations (5) and (10) were developedas follows'. using a limited set of experimental data in low

pressure air/water flows, it is expected that the

,E. = tarih(7.25 x ICY' e,'2' Reo 5) (5) correlations may not apply directly to high pressuref situations.

where We, is defined in Equation 2).

448

Page 3: Entrainment Measurements in Annular Flow

3 Scaling Equation (15) has one more dimensionless

The current experiments were designed to group than equation ( 2, Re.,

simulate steam/water flow at 13.6 MPa in a small To obtain similarity the five dimensionlessdiameter tube. groups on the RHS of equation (1 5) should be the

The difficulty with scaling the interfacial same. Table is a comparison between a steam/phenomena in annular two-phase flow is that they water reference case and six experimental cases-are not well understood. The state-of-the-art The hydraulic diameter is 6 mm for the referencecorrelations are empi6cal. We have chosen the best case and 10 mm for the experiments. Freon-113known dimensionless correlations in the hope that and airtwater are used in this analysis.the dimensionless numbers that they include are The velocities, j and j., are chosen such that Re,

sufficient to scale the interfacial mechanisms. and We. are similar. The only other variable that is

The entrainment rate correlation of Kataoka and controlled is the pressure.Ishii 1982) was derived based on the correlation by The Reynolds number for the gas phase, Reg.

Ishii and Mishima 1989). For fully developed turns out to be within a factor of two of the referenceannular flow they obtained: value for all cases. However the density ratio and

the viscosity ratio vary greatly. The closest valuesare obtained with Freon-113 at 2 MPa and in fact

cD = 66 x 10-7 0i 135 0.9125 they are quite close. On the other extreme air/waterRe We I (,jAlf at 0.5 MPa exhibits values which are more than one

order of magnitude greater than the reference case.

where Reif = Re, (I-E). Combining equations (11) Furthermore the gas velocity at this condition is very

and (5) we obtain.- high, beyond practcal limits.There is one further advantage with Freon-113,

that the surface tension is very low. In fact it issmaller than the reference condition. This iseD Pr Pf (12)

P = O(Wer, Re,, important in case that some significant'r P, 'U' dimensionless group was missed.

The interfacial shear correlation of Wallis 1969)is based on the premise that the interfacial Table I Annular Flow Scaling.roughness is proportional to the film thickness:

Fluids P T il j & Rel Re, We, pW, gV�L,

c. = .005(1+ 300D (13) Wa C MIS M/3

HenstocK and Hanratty 1976) used the Steam/ 13.6 334 0.5 20 2.3 4.8 1.4 7.5 3 92

approach that the flow in the film is similar to single- Water I IE+4 E+5 E+4 I I

phase flow. The film was assumed to be uniform Freon '2 180 0351 1.347 2.3 73 '1.4 7.1 10.92

and the mixing length model was used to calculate (113) E+4 E-5 +4

the liquid velocity to obtain: Freon 2.3 7.3 J.41 140 0.42 15.95 F 19.3 16.23

(113) E+4 E+5 _+4

h 6.59F -(Re,,) ,Where = - . (14) Freon

Re 0.9 P/ 0.5 100 0.503 27.49 2.3 7.3 E1.4 40.9 23.0D _jl + -l400F 'U' FTf (113) E+4 E+5 +4

and yRelf) is an algebraic functon. Air/ 2 20 2.32 7 .4.471 2.3 ELO 1.4 42 4 52.63Water E+4 +6 J:+4

By a similar argument as used for equations 12) Airl 1 20 2.327 11. 51 2.3 7.4 84.7 52

it follows thati Water I E,4 E+5 E+4

Air/ 0.5 20 2.327 1 OS.9 3 2 1 4 169 52.3

C y (We,, Re,, Re,, 'uf Water E+4 E�5 E+4

Pg Pg

449

Page 4: Entrainment Measurements in Annular Flow

4 Experiments extraction unit decreased. When the extracted air

4.1 Air/Water experiment. flow increased further, a dramatic change of the flowregime in the visualization section was seen. The

The experimental loop utilized is similar to tube turned from opaque to transparent. After that,

Cousin and Hewitt's 1968). One of the main no matter howmuch more airflowwas extracted, nodifference of the flow regime was observed. It was

objectives of the present work is to extend the range assumed that the liquid was extracted completely atof their data to higher flows and pressures. that point.

There are 121 experimental data points. The But for high water flows, it was hard to tell whenrange of experimental data was extended on both the liquid film was extracted completely by

air and water flows. The range of Pf jf 2 is 5.5 to 289 visualization. A plot of extracted liquid flow vs.

kg/ms2 and the range of pgj.2 is 480 to 45000 kg/ extracted air flow was needed to determine when all

MS2 (see Figure 3 The experiments were the liquid film was extracted. Two samples areconducted at four different pressures. All shown in Figure 4 for low and high water flows. Farmeasurement ranges are listed in Table 2 a certain inlet condition, the extracted liquid flow

reaches a plateau beyond a certain value of theextracted air flow. The higher the inlet water flaw,

Table 2 Range of parameters. the greater percentage of the inlet air flow thatneeds to be extracted to reach the plateau. Once onthe plateau it is assumed that the liquid film is

Parameter Unit Range extracted completely.

The amount of extracted gas was always theAir flaw kg/sec 0.0028-0.028 minimum necessary to remove the liquid film.

Water flow kg/sec; 0.0053-0.038 Furthermore the pressure drop across the poroustube was minimized to minimize the gas extraction-

if m/sec 0.074-0.54 This was achieved with a pore size of 100 gm aftercomparing measurements with 20 m, 40 m and

g m/sec 24.5-126 1 00 m porous tubes.On the average the extracted gas was only 15%

Pressure kPa 140-240-390-660 of the total gas flow. The worst case was only 10%.I I I I Therefore the error induced by the gas extraction is

generally small.4.2 Entrainment measurement (air/water).

The water injected into the test section forms a 4.3 Freon-113 experiment.

liquid film around the periphery of the tube. As the In order to scale properly annular steam/waterliquid film flows up the tube, part of the liquid film 'is flow at high pressures and temperatures Freon hasentrained as fine droplets in the gas core. When been shown to be one of the best fluids available. Infully developed flow is established the entrainment Table I shows that it is possible to obtain the samerate is equal to the deposition rate and the density ratio as steam/water at 13.6 MPa usingentrainment fraction reaches its asymptote value. Freon-1 1 3 at 2MPa.

Since the length between the top of the mixer to the A unique annular two-phase loop (Figure )inlet of the first extraction unit is about 440 using vaporAiquid Freon was designed and built todiameters, fully developed annular flow is expected. scale the steamtwater conditions. Vapor is produced

The entrainment fraction, E, can be calculated inside a vapor generator 20 kw) and is mixed withfrom the following expression: Freon liquid in the inlet of the test section to produce

annular flow. The pressure of the vapor generator is

,E= I-la controlled automatically according to the set pointWI' (16) established for the experiment. The first extraction

unit works the same way as in the airlwater loop.Additional precautions were taken to avoid

To monitor the liquid film extraction, the flow condensation when the liquid is extracted. Thisimmediately downstream of the extraction probe liquid film goes to a flowmeter tank where the levelwas observed. When the extracted air flow was can be read and the mass flow rate calculated. Twoincreased, the liquid film downstream of the drain valves at the top of the flowmeter tank, with

different discharge coefficients, were installed to

450

Page 5: Entrainment Measurements in Annular Flow

control the optimal extraction Pint, i.e., when the Figure 9 shows the comparison of the correlationplateau is reached. Thermocouples were installed by Dallman et. al. 1979) with all the data. Thebefore and along the test section to check that the correlabon fits all the air/water data well with kA=5.4

data was obtained at steady-state saturated x 106 S21kg and WLFC/P =0.046 kg/ms. Although the

conditions. The range of the experiments were� scatter is appreciable, Dallman et al.'s correlation

1 00 <gjg2< 23000 and 125 <f �2< 325 at 25 and does account for an asymptotic lower limit to the film

1 0 bar (Figure 6 flow, so the scatter is more random compared to

Ishii and Mishima's correlation. However the5 Results correlation does not match the Freon-113 data.

Figure 7 shows a comparison of Ishii and Evidently the dimensional coefficients must beMishima's correlation 1989) and the four data sets '' changed but it is not known how to do it at present

Cousins and Hewitt (1 968), Keeys et. al. (1 970), thepresent airtwater data and the present Freon-113data. 6 Conclusion

The dimensionless group Well.25Re,0.25 The two new data sets that have been obtained

collapses all the data surprisingly well and it fits the are consistent with and extend previous entrainmentdata by Cousins and Hewitt very closely. This is not data sets. Because the old data sets did not overlapsurprising since these data were use to obtain the it was not possible to find what dimensionless groupcorrelation. Furthermore the correlation is in collapses the entrainment data. However the new

agreement with all the data for Well.25Relo.25 < 106. data sets provide plenty of overlap between low

The scatter observed in the new data at values of E pressure air/water data and high pressure Freon-

below 01 is related to the uncertainty in the 1 3 data.measurements and to the logarithmic scale which Therefore it is now possible to show that theamplifies the effect. The same plot with a linear dimensionless group proposed by Ishii and Mishimascale is shown in Figure and, of course, the (1989) scales data for a wide range of conclitions,

scatter is reduced in this region. and in particular for high pressure steam/waterFor Well.25Re,0.25 > 106 the correlation no flows. However the correlation by Ishii and Mishima

longer fits the data. However the remarkable fact is is not properly calibrated for Well-25Re,0.25 , lor'.

that the low pressure air/water data, the high Furthermore it does not account for the asymptoticpressure steam/water data and the Freon-11 3 data lower limit of the film flow rate observed at high gasare collapsed in this region. Nevertheless there is flows. The new sets of data may be used to correct

considerable scatter as shown in Figure 8. The the correlation for these two effects.

scatter of the airlwater data set is systematic and

depends on the liquid Reynolds number. There is an 7 Referencesasymptotic lower limit to the film flow rate as the airflow is increased. This was observed because of the Ishii, M. and Mishima, K., 'Droplet entrainmentvery high air flows that could be achieved in the correlation in annular two-phase flow', Int. J. Heatexperiment. This is not considered in Ishii and and Mass Transfer, Vol 32, n 10, pp 1835-1846,

Mishima's correlation. Because of its significance, 1989.this phenomenon deserves to be studied separatelyand it will not be discussed any further at present. Cousins, L. B. and Hewitt, G. F., 'Liquid Phase

The scatter in the Freon data is primarily due to Mass Transfer in Annular Two-Phase Flow: Dropletcondensation in the loop. It is impossible to Deposition and Liquid Entrainment', UKAEA Report

eliminate all condensation and it is difficult to AERE-R5657, 1968.

determine where it is taking place and to correct thedata accordingly. Because the Freon loop has two Keeys, R. K. F., Ralph, J. C. and Roberts, D. N.,extraction units we were able to develop a 'Liquid entrainment in adiabatic stream water flow at

procedure to correct the data that works quite well 500 and 1000 psi', AERE-R-6293.

but the reduction of this error is an on-goingprocess. The scatter in the data of Keeys' et. al. is Dallman, J. C., Jones, B. G., and Hanratty, Talso considerable and we believe that it is related to J.."Interpretation of Entrainment Measurements incondensation as well. Annular Gas-Liquid Flows", Two-Phase

Momentum, Heat and Mass Transfer in Chemical,

451

Page 6: Entrainment Measurements in Annular Flow

Process and Energy Engineering System, Vol. 2,681-693, Hemisphere, Washington, D.C_ 1979.

Wallis, G. B., 'One Dimensional Two-PhaseFlow', McGraw-Hill, 1969.

(WLE)2

S2

Zo

(WLE)l

Z

-71

WATER INLET

AIR INLET

Figur I Test section for Cousins and Hewitt's 1965) experiment-

452

Page 7: Entrainment Measurements in Annular Flow

STEAM ROPLETS

ORIFICE ' T CDENSER ORIFICE FLOWMETEA'Oi

SINTER TRACE MEATING

FILM EMOVALDevice VI

SIGHTGLASS

:V2

ORIFICELL F LOWM TER ;

\-LIOUID FILM

ERDROPLET INSTEAM FLOW

TO INLET OFMAIN LOOPWATERCIRCULATOR

\-TEST SECTION0.497IN D)

If 26 X 10-itn.i-D)

CANNEDROTOR PMP

MIXER Box

ER

AM

Figure 2 Test section for the experimentorKeey.-i et aL (1970)

453

Page 8: Entrainment Measurements in Annular Flow

le+5 - 1

O0

Ie+4 - 8

00

0 0 Wspy AnnularIe+3 O

S

Annular

c'

c. 1 e+2 -

Bubbly

Chum

1e+1 - 0 Present Work0 Cousins Hewitt's data

Bubbly-Slug (ZD = 15 fl)

Slug

le+O -, I I I I I

1e+O 1e+1 le+2 le+3 le+4 le+5

Pf k2(kg/m2s)

Figure 3 Flow regime map with airiwater data.

454

Page 9: Entrainment Measurements in Annular Flow

100

80 0

AA A A A

60 -0

0

0 A

40

LU

0

20 A j,=0-15M/Sjg=53rTVsP=24OkPao jf = 136 m/s, j, = 11.2 m1s, P = 660 kPa

0 T

0 2 4 6 8 1 0 1 2 1 4 1 6 1 8 20 22 24

Extraction gas flow (%)

Figure 4 Extraction Liquid Flow vs. extraction gas flow.

455

Page 10: Entrainment Measurements in Annular Flow

Vj-

VP"F I L'OuvbouiDbativ ZZtru=.vc"

..... To mw�

POM3UwM

cm.,c

. . ... ......

..................

TcATw

TR"=R NP,

Figure 5 Vapor/liquid Freon-113 experimental loop.

456

Page 11: Entrainment Measurements in Annular Flow

1 e6 - -71 e5 - 0 Freon data (1 0 bar)

0 0 0 Freon data <2.5 bar)1 e4 - 0 0 0

00 4 O CD 0CD c 0

1 e3 - 0 0cn Wispy-annular

Annular1 e+2 - 0

---------- - ---------------------L--------------------------

Churn1e+1 - Bubbly

1 e+O -

Bubbly-slule-1 Slug 9

1 e-2 1 1 1 1 1 __ I I

le+O 1e+1 le+2 le+3 le+4 le+5 le+6 le+7

Pjj2j (kg/mS2)

Figure 6 Flow regime map with vapor/liquid Freon-113 data.

457

Page 12: Entrainment Measurements in Annular Flow

1.00

0017 0

17,

LU 0.10 0000 0

0

00

- Ishii and Mishima's Correlation

0 0 0 AirAvater data

0 0 Cousins and Hewitt's Data0 M Freon data 10 bar)

0 0 v Freon data (<2.5 bar)0 0 Keeys'data

0

0.01

le+4 le+5 le+6 le+7 le+8

Wei 1.25 RefO.25

Figure 7 Comparison of Ishii and Mishima's correlation with data

458

Page 13: Entrainment Measurements in Annular Flow

1.00

v0.80

0C#co

0.60

W 000

v 0 00.40 - v

- Ishii and Mishima's Correlation

0.20 - 0 Airtwater data0 Cousins and Hewitt's Data

M Freon data 10 bar)v Freon data (<2.5 bar)* Keeys'data

0 0

0.00

le+4 le+5 le+6 le+7 le+8

We,'-25 RefO.25

Figure 8 Comparison of Ishii and Mishima's correlation with data

459

Page 14: Entrainment Measurements in Annular Flow

Dallman et. al.'s Correlation0 New Data (W < 0056 kgIs)

0 Cousins and Hewitt's Data

1.0 C> Freon 113 data

00.8

0 00.6 - O 'BO

MLU 0

W0

0.4 - 00

0

0.2 - CP

0

0.0 � - I - 1 . I . I -

1e+1 1 e2 1 e3 I e4 1 e5 1 e6

D jg3 gO.5 fO.5

Figure 9 Comparison of Dallwan et al. correlation with data

460