ø392
504
302
□215
●
150.4 W・158.2 lm/W・3.6 kg
EL-C20034N-ID 2AHTN
23,800 lm
150.4 W (136 W)・158.2 lm/W・5.5 kg
23,800 lm
EL-C20032N-ID 2AHJ
114.1 W・151.6 lm/W・3.1 kg
EL-C15034N-ID 2AHTN
17,300 lm
114.1 W (103 W)・151.6 lm/W・4.7 kg
17,300 lm
EL-C15032N-ID 2AHJ
303.7 W (275 W)・154.7 lm/W・10.0 kg
EL-C40032N-ID 2AHJ
47,000 lm
228.0 W・150.0 lm/W・5.3 kg
EL-C30034N-ID 2AHTN
34,200 lm
228.0 W (206 W)・150.0 lm/W・8.0 kg
34,200 lm
EL-C30032N-ID 2AHJ
93
93
93
93
93
93
93
EL-X0096
●●−
−
EL-X0095
−
−
●−
EL-X0090
−
●−
−
EL-X0098
−
●●−
EL-X0049
−
●●−
EL-X0051
●●●−
EL-X0089
−
−
●−
EL-X0099
●●●●●●
EL-X0091
●−
−
−
High tempresistant
Up to
+55°C
5460,000
hrs60,000
hrs
LED High Ceiling Base Light
Square type (general·power, saving) and round type lightweight model compliance
High-pressure mercury vapor (HPMV) lamps for general lighting
Minamata Convention on Mercury was adopted and signed on October 2013.
Replacement with is recommended.
SeriesLED High Ceiling Base LightHigh Bay
In Indonesia, Manufacturing, import, and export of Mercury lamps may be banned in the near future.
* Metal halide lamps and high-pressure sodium lamps are not included. * Except for mercury vapor lamps for general lighting, most of commercially available mercury-containing lamps such as �uorescent and HID lamps have already met the requirements of the amount of contained mercury and will not be affected by the regulation. They can continue to be purchased and used also after 2021.
Indonesian government has been accession to this convention at
22/09/2017.
5460,000
hrs
5460,000
hrs
Specialenvironment model Recommended for indoor special environments
For high temp
Square type
Wide-angle light distribution (93°)
Recommended for outdoor special environments (Rainproof and dustproof speci�cation)
Square type
For under eaves·salt-resistance·low temp
Wide-angle light distribution (93°)
2A: Voltage 200 to 242 V A: Voltage 100 to 242 V compatible HJ: Initial illuminance correction HTN: Step dimming function
• Operating ambient temperature range: Class 4000, 3000: -10°C to +55°C (Power-saving mode: 60°C)Class 2000, 1500: -10°C to +60°C (Power-saving mode: Class 2000 65°C , Class 1500 70°C)
• Capable of being mounted on 30° or less steeper slanting ceiling
• Ra75
: Daylight white (5000 K) • Average power within parentheses (at 200 V) • 5-year warranty 5-yearwarranty
• Operating ambient temperature: -25°C to +40°C• Capable of being mounted on 30° or less
steeper slanting ceiling• Lead wire included• Ra75
* For information on the options of other special environment models, please contact us separately.
(Indoor speci�cations)
Specialenvironment model
Class 3000
Class 2000
Class 1500
Class 1000
Bottom guard Whole guard Wall mounting bracket Chain hanging bracket Ceiling boxmounting bracket Fall-prevention wire
* IP code represents the degree of protection provided by electrical appliances against foreign substances such as dust and water de�ned in “Degrees of protection provided by enclosures (IEC60529)” in IEC standard.
* For models for high temp and heavy-duty salt-resistance/oily smoke-proof·high temp, operating ambient temperature varies by class and in power-saving mode.
+10 ºC UP !Approx. 25%power saving
ON/OFF operations 4 times
Switch to power-saving modeON OFF
25 °C on average
55 °C on average
Table of operating ambient temperature range for special environment model
For shock resistance in crane
For high temp
For under eaves·salt-resistance·low temp
For under eaves·salt-resistance·low tempRound type
Salt damage environmentSquare type
Other environment
LED High Ceiling Base Light
PT. Mitsubishi Electric IndonesiaGedung Jaya 8th Floor, JI. MH. Thamrin No.12 Jakarta Pusat 10340, Indonesia
TEL: (+62) 21-31-6461
Energy Saving and Long Service LifeReduction of running cost
1
Long LED service life of 40,000 to 60,000 hours Easy replacement of lamps.
High Functionality and Less Installation Time and Work2 Enhanced functionality and savingin time and work during installation
Lightweight and compactMore compact compared to predecessors. Capable of being mounted to existing ceiling box. Four screws for installation of round lightweight model. Use of option for square type.
Note: Properly insert the power wires and the ground wire into the individual insertion holes in the power supply terminal block.
*Compatible Power wire : ø1.6 to 2.0 VVF
Existing mercury-vaporlamp unit
High Quality and Ease3 High quality obtained by passing strict tests and safe long warranty
Mass
2.9 kg*
In accordance with guidelines* of Ministry of Education, Culture, Sports, Science and Technology, fall-prevention wire provided as standard. Second optional fall-prevention wire can be also installed.
Dif�cult to scatteredUse of chipproof polycarbonate resin in bottom cover.* Unlike HID lighting units, the product does not break easily without a glass lamp when a ball hits it.
5-year warranty
Safety obtained by passing rigorous tests
In addition to compliance with Electrical Appliance and Material Safety Law, JIS, and Japan Lighting Manufacturers Association Standard, we de�ne our own stricter quality and safety standards in-house to deliver highly reliable and safe products.
* According to the testing laboratory accreditation system of JNLA (Japan National Laboratory Accreditation system) for light measurement of LED products for lighting services, our company is accredited as a laboratory that conducts light performance testing of JIS C 8105-5 (Luminaires) and JIS C 7801 (Self-ballasted LED-lamps) by International Accreditation Japan (IAJapan), National Institute of Technology and Evaluation (NITE).
Fall-prevention wire provided as standard
Laboratoryaccreditedby JNLA*
Furthermore
Generallighting unit
Guidelines for earthquake-resistant design
Facility classi�cation and speci�ed facility*1
Mounting on special ceiling*2
Earthquake-resistant class S2Design horizontal seismic coef�cient: 2.2
Design vertical seismic coef�cient: 1.1Maintenance of limited function*3
Compliant with “Guidelines for earthquake-resistant design and installationof lighting units” of Japan Lighting Manufacturers Association
HB seriescompliance
*1: Speci�ed facility…It refers to “Facility necessary for activities in emergency disaster control measures”, “Facility speci�ed as evacuation site”, and “Facility where ensuring safety of human lives and goods is particularly required.”
*2: Special ceiling…Facilities reinforced to prevent fall of decorative laminates due to earthquakeIt refers to earthquake-conscious ceilings reinforced for earthquake resistance.
*3 Maintenance of limited performance…Capability of being lit all the time* With use of an option, a part of models are not compliant with the guidelines.
* In the case of using more than 20H a day, 2.5-year warranty
Reduction of maintenance with long service life
LED
Light source service life comparison
12,000 hrs
* At 85% lumen maintenance factor (estimation)
Mercury lamp400 W unit
40,000to
60,000hrs
L85
-25°C -10°C-25 °C-25 °C -10 °C-10 °C +35 ºC +40 ºC +60 ºC +70 ºC+35 ºC +40 ºC +60 ºC +70 ºC+35 ºC +40 ºC +60 ºC +70 ºC
Mitsubishi Electric LED Lighting
Prepared in 2017-12
Quick Guide
2017-12
Rainproof Dustproof Salt-resistantLow tempresistant
Up to
-25°C
60,000hrs
Rainproof Dustproof Salt-resistantLow tempresistant
Up to
-25°C
Rainproof Dustproof Salt-resistantLow tempresistant
Up to
-25°CHigh tempresistant
Up to
+60°C
High tempresistant
Up to
+60°C
60,000hrs 54
60,000hrs
Rainproof Dustproof Salt-resistantLow tempresistant
Up to
-25°C
Commitment to High Bay Series
Approx.
3.3 to 5 times longer service life
* Power-saving model integrated power supplyClass 1500/1000
* “Guide for measures to prevent fall of ceiling and others in school facilities” (Issued in August 2013)
* Tempered glass cover for heavy-duty salt-resistance/oily smoke-proof·high temp
For heavy-duty salt-resistance/oily smoke-proof·high temp
High Bay Series
Ground
For feed-through For power supply
Release hole
Power supply terminal block
Properly insert
Sheath removal length
12 mm
Power wire for high potential
Power wire for low potential
Ground wire Outer sheath
ON/OFFoperations
4 times
ON OFF
ON/OFFoperations
4 times
ON OFF
ON/OFFoperations
4 times
ON OFF
Which one is suitable for you?
High Bay SeriesLED High Ceiling Base Light
SNICETIFICATED
MC Series Quick Reference A4 Gate-fold Front
208mm 210mm 210mm
HB Series Quick Guide A4 Tri-fold Revision Front
208mm 210mm 210mm