Page 1 EuroFlow - a guideline for Leukemia & Lymphoma flow cytometry panel This document serves as an internal guide to prepare for customer visits 1. Situation In 2009, the Euroflow Consortium (www.euroflow.org ) issued a guideline for the flow cytometric immunophenotyping of normal, reactive and malignant leukocytes 1) . The purpose of the guideline was to move the flow cytometry community closer to standardization. The work will allegedly be published in 2010 in a peer-reviewed journal but that journal has not yet been disclosed. Unlike other previous publications aimed at standardization, the EuroFlow guideline is the first to recommend defined fluorochrome combinations in context of specific clones and vendors. The Euroflow Consortium is a non-profit organization 2) , actively participating in numerous flow cytometry events and congresses worldwide. Participation at these venues includes lectures and presentations aimed at building awareness and enrollment with the EuroFlow guideline. The guideline is put forward as a cook- book” no-questions asked guide-line. The Consortium consists of a handful of the most prestigious scientists within flow cytometry. In total, the panel consists of 124 different flow conjugates, with a split in terms of listed reference products including vendor being: BD: 63 conjugates plus 15 custom conjugates or 63% BC: 12 conjugates or 10% Dako: 7 conjugates or 6% Other: 27 conjugates or 21% In figure 1, the overall panel from the guideline is depicted. For every disease category highlighted by a red circle, the EuroFlow Consortium has put together an 8-color panel comprising one or more tubes. When each panel is analyzed for Dako portfolio 3 categories emerges: Dako´s product is the reference product in the recommended panel Dako´s portfolio includes the recommended fluorochrome/antibody/clone but Dako is not recommended Dako´s portfolio includes the recommended fluorochrome/antibody combination but with a different clone

Upload: ajaysardesai

Post on 23-Oct-2015

166 views

Category:

Documents


16 download

DESCRIPTION

Euroflow Guidelines for Dako Distributors

TRANSCRIPT

Page 1

EuroFlow - a guideline for Leukemia & Lymphoma flow

cytometry panel

This document serves as an internal guide to prepare for customer visits

1. Situation

In 2009, the Euroflow Consortium (www.euroflow.org) issued a guideline for the flow cytometric

immunophenotyping of normal, reactive and malignant leukocytes1). The purpose of the guideline was to

move the flow cytometry community closer to standardization. The work will allegedly be published in

2010 in a peer-reviewed journal but that journal has not yet been disclosed. Unlike other previous

publications aimed at standardization, the EuroFlow guideline is the first to recommend defined

fluorochrome combinations in context of specific clones and vendors.

The Euroflow Consortium is a non-profit organization2), actively participating in numerous flow cytometry

events and congresses worldwide. Participation at these venues includes lectures and presentations aimed

at building awareness and enrollment with the EuroFlow guideline. The guideline is put forward as a cook-

book” no-questions asked guide-line. The Consortium consists of a handful of the most prestigious

scientists within flow cytometry.

In total, the panel consists of 124 different flow conjugates, with a split in terms of listed reference

products including vendor being:

BD: 63 conjugates plus 15 custom conjugates or 63%

BC: 12 conjugates or 10%

Dako: 7 conjugates or 6%

Other: 27 conjugates or 21%

In figure 1, the overall panel from the guideline is depicted. For every disease category highlighted by a red

circle, the EuroFlow Consortium has put together an 8-color panel comprising one or more tubes. When

each panel is analyzed for Dako portfolio 3 categories emerges:

Dako´s product is the reference product in the recommended panel

Dako´s portfolio includes the recommended fluorochrome/antibody/clone but Dako is

not recommended

Dako´s portfolio includes the recommended fluorochrome/antibody combination but

with a different clone

Page 2

1) EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal,

reactive and malignant leukocytes, J.J.M Van Dongen et al.

http://www.euroflow.org/imagenes/news/euroflow_handout_on_antibody_panels.pdf

2) www.euroflow.org

Table 9

Page 3

Below table summarizes the result:

Dako is listed as reference product

Dako has required clone/fluorochrome but is not

listed as reference product

Dako has the recommended antibody conjugate with

different clone

Panel 1 Acute leukemias screening panel (ALOT)

MPO/FITC (F0714) CD79a/RPE (R7169)

CD3/CY (PB982)

Panel 2 Mature lymphoid cells (LST)

CD56/RPE (R7251*) CD4/PB (PB983) CD8/FITC (F0765) CD3/APC (C7225) smlgλ/FITC (F0434) smlgк/RPE (R0436)

Panel 3 Mature lymphoid cells (SST)

CD56/RPE (R7251)* CD3/APC (C7225) CD8/FITC (F0765) smlgλ/FITC (F0434) smlgк/RPE (R0436)

Panel 4 Plasma cell dycrasias (PCD)

CD45/PB (PB986) Cylgк/APC (C0222)

CD56/RPE (R7251)* CD117/APC (C7244)

CD38/FITC (F7101)* CD28/RPE (R7163)

Panel 5 B-cell precursor ALL (BCP-ALL)

TdT/FITC (F7139) CD117/APC (C7244) CD15/FITC (F0830) CD33/RPE (R0745) CD13/RPE (R0715) CD22/APC (C7281) cylgμ/FITC (F0058)

Panel 6 T-cell ALL (T-ALL)

Tdt/FITC (F7139) CD3/PB (PB982) CD117/RPE (R7145) CD13/RPE (R0715)

CD2/FITC (F0767)

Panel 7 Acute myeloid leukemis and myelodysplastic syndromes (AML & MDS)

TdT/FITC (F7139) CD64/RPE (R7219) CD56/RPE (R7251)

CD16/FITC (F7011) CD13/RPE (R0715) CD15/FITC (F0830) CD22/APC (C7281) CD41/FITC (F7088) CD25/RPE (R0811) CD61/FITC (F0803)

Panel 8 B-cell chronic lymphoproliferative diseases (B-CLPD)

CD23/FITC (F0765) CD56/RPE (R7251)* CD95/RPE (R7154) CD103/FITC (F7138)

CD8/FITC (F0765) smlgλ/FITC (F0434) smlgк/FITC (R0436) CD3/APC (C7225)

Panel 9 T-cell chronic lymphoproliferfative diseases (T-CLPD)

CD4/PB (PB983) CD5/FITC (F0795)* CD7/FITC (F7276)* CD25/RPE (R0811) CD27/FITC (F7178) CD57/FITC (F7270)

Panel 10 NK-cell chronic lymphoprolifeartive diseases (NK-CLPD)

CD57/FITC (F7270) CD25/RPE (R8011) CD5/APC (C7242)*

*Please consult Appendix B for results from Dako´s internal competitor comparison studies.

Page 4

2. Which are the EuroFlow issues that Dako needs to deal with?

Many customers consider the EuroFlow recommendations as the future for leukemia/lymphoma

immunophenotyping. The perception is that the fluorochrome combinations selected by EuroFlow

including clones and vendors were selected as a result of best-in-class performance.

Here are the facts:

The Euroflow guideline does not list the number of vendors tested for each marker

The Euroflow guideline does not list the number of clones tested for each marker

The Euroflow guideline does not reveal the criteria a product must meet to be

referenced

Some customers believe that they do not need to validate their panels as long as the

combination complies with the Euroflow recommendations – this is not the case

Apparently, BD has bought the name and logo EuroFlow

From the ESCCA Euroflow meeting 2010, it was announced that:

Euroflow may potentially only have tested one or two vendors for each antibody, thus it

would be impossible to know it the recommended products are indeed best-in-class

Dako was never contacted during the process

BD was chosen because they offered high discounts

3. Market reaction & Objection handling scenarios

Objection 1: “I believe that the references recommended by the EuroFlow panel are of the best quality”

Reply: The Euroflow panel has not tested all clones from all vendors – and nowhere in the guideline do they

state to have done so. Apart from the reagents where EuroFlow list Dako as vendor, we have 9 products

with the recommended clone/fluorochrome combination and 22 reagents of requested

antibody/fluorochrome combination but with a different clone (please see section 1 and Appendix for more

details).

Further to that, EuroFlow has not defined explicit specifications reflecting the required quality and it is

unlikely that Dako´s products should not be of at least equal quality, both in terms of signal-to-noise ratio

and the explicit degree of fluorescence intensity.

Objection 2: “When I use the EuroFlow panel I don´t need to validate the setup”

Page 5

Reply: It is correct that you don´t need to validate the exact composition of antibody/fluorochrome

combination. But when it comes to validating the individual components of the panel there are no

exceptions to the Clinical & Laboratory Standard Institute recommendations reflected in guidelines H42a

and H43a. In fact EuroFlow gives no indication of what concentration each of their recommended products

should be used at. Optimal antibody concentration must be determined during the laboratory validation

process.

4. Questions to ask to open up for a dialogue regarding EuroFlow

Does the customer intend to comply with the EuroFlow guideline? If so this means that:

o The customer uses all 124 conjugates including custom conjugates?

o The customer has or will purchase Infinicyt software?

Would the customer be interested in trying/using products that have not been validated

by EuroFlow but where Dako can show similar performance as the reference product?

Does the customer follow the EuroFlow guideline 100% (if not, this opens for a dialogue

regarding the remaining panels)

Will the customer use all 124 conjugates?

How will the customer decide on the titrations of the antibodies?

How does the customer intend to validate the panels?

How will the customer get access to custom conjugated antibodies?

What will the cost be for running the whole Euroflow system?

Has the customer conducted a health benefit to cost analysis for adoption of the

EuroFlow guidelines?

5. Key take-home-message

In the most important panel in terms of volume: the acute leukemia panel, Dako has 25%

marker coverage. Therefore, if the laboratory has adapted the EuroFlow

recommendation Dako should capture 25% of that panel´s sale.

Apart from the recommended markers, Dako has additional 9 reagents of exact

clone/fluorochrome combination

Further to that, Dako has 22 reagents of recommended antibody/fluorochrome

combination but with a different clone

Page 6

Where Dako´s reagents are not recommended, the reagent has – to our knowledge - not

been tested by EuroFlow therefore they should not be automatically dis-qualified.

It is not correct that customer’s don´t have to validate the individual markers. It is the

responsibility of anyone wishing to follow EuroFlow to ensure that individual

components work as required – if they do not, the concept will not work. This includes

control over both signal strength influenced by instrument setup as well as back-ground

influenced by unspecific binding but also spill-over from other channels caused by e.g.

changes in signal strength or natural decay of tandem fluorochromes.

Page 7

6. Appendix A

Analysis of the EuroFlow recommendations and Dako compliance

In the following, each panel is listed with information covering:

Dako´s antibody flourochrome is recommended in the panel

Dako´s portfolio includes the recommended fluorochrome/antibody/clone

Dako´s portfolio includes the recommended fluorochrome/antibody but with

a different clone

Table 1: The ALOT panel is the initial screening panel for acute leukemia orientation type. It is

recommended to screen all types of leukemia wherefore the impact for a vendor being recommended here

may have a significant business impact. Dako is recommended to 25% of the total panel (2 reagents out of

8).

Table 2: The lymphoid screening tube is designed for evaluation of several suspected clinical conditions,

such as lymphocytosis, lymph node enlargement, splenomegaly, monoclonal serum components etc.

Table 3: Screening tubes designed for evaluation of suspect small samples and samples with very low cell

counts, such as fine needle aspirates (FNA), cerebrospinal fluid (CSF) vitreous humor etc.

Page 8

Table 4: The 2 tubes aim at identification and enumeration of plasma cells as well as at the discrimination

between normal polyclonal plasma cells such as in reactive plasmacytosis versus aberrant monoclonal

plasma cells such as in MGUS, MM and PCL.

Table 5: This panel aims at the recognition and classification of all classically defined BCP-ALL or alternative

BCP-ALL classifications including immunophenotypic classifications associated with well-defined molecular

aberrations, such as specific fusion genes.

Page 9

Table 6: This panel consists of 4 tubes aiming at recognizing and classifying all classically defined T-ALL.

Table 7: This is the panel for acute myeloid leukemias and myelodysplastic syndromes.

Page 10

Table 8: This panel is designed to diagnose mature B-cell malignancies according to WHO entities using flow

cytometric data only.

Page 11

Table 9: The EuroFlow T-CLPD panel aims for diagnosis and classification of mature T-cell malignancies.

Page 12

Table 10: This panel aims at the discrimination between aberrant and normal/reactive NK-cells.

Page 13

Appendix B