fabrication and design considerations for microfluidics-based tactile sensors for prosthetic hand...
Post on 20-Dec-2015
218 views
TRANSCRIPT
![Page 1: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/1.jpg)
Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for
Prosthetic Hand
Shehreen DhedaFaculty Mentor: Abraham P. Lee, PhD
Graduate Mentor: Jeffrey S. FisherDepartment of Biomedical Engineering,
University of California, IrvineAugust 31, 2006
Inter-Micro/Nano Summer Undergraduate Research Experience (IM-SURE)
![Page 2: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/2.jpg)
Outline:
Biological mechanoreceptors of the human hand
Our synthetic tactile sensor design Device manufacturing and characterization
techniques and their outcomes Conclusions Acknowledgements
![Page 3: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/3.jpg)
Biological Mechanoreceptors of the Human Hand
Kandel, E. The Principles of Neural Sciences, 2000
Slowly Adapting(SA(SA
) ) afferen
ts
Rapidly Adapting (RA) (RA) afferent
s
(SA)(SA) (SA)(SA)(RA)(RA)(RA)(RA)
![Page 4: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/4.jpg)
Synthetic Tactile Sensor Design
mimics Merkel cell-slowly adapting type 1
(SA-1) afferents
mimics Meissner corpuscles-rapidly adapting (RA) afferents
![Page 5: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/5.jpg)
Device Components
Materials used are poly(dimethylsiloxane) (PDMS) and polyimide or glass. Reservoir shape molded into PDMS, and electrodes laid onto the polyimide/glass.
![Page 6: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/6.jpg)
Filling Techniques
Three different methods have been investigated:
1. Syringe2. Pump3. Channel Outgas Technique (COT)
(Monahan et al, 2001)
Monahan et al., Anal. Chem. 73: 3193-7 2001
![Page 7: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/7.jpg)
Issues with Filling Techniques Air bubbles formed in reservoir with syringe and
pump methods.
For pump and COT method, sealing of PDMS where holes are made is necessary.
COT needs modification to allow for selective filling.
![Page 8: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/8.jpg)
Fluid Loss from the Devices
Devices were filled using asyringe and sealed with
uncuredPDMS. They were kept at room temperature for a number ofweeks and the loss of fluid outof the devices was tracked.
Air bubbles on days 1, day 8 and day 16 respectively.
![Page 9: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/9.jpg)
Mechanical Modeling of Sensor
Stress within PDMS layer
Fluid flow inside reservoir
![Page 10: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/10.jpg)
Conclusions
Improvements to existing filling techniques or more techniques need to be explored.
Fluid loss is possible, so prevention is needed.
Fluid flow from reservoir is linear to applied pressure. Other geometries and models should also be investigated.
![Page 11: Fabrication and Design Considerations for Microfluidics-based Tactile Sensors for Prosthetic Hand Shehreen Dheda Faculty Mentor: Abraham P. Lee, PhD Graduate](https://reader036.vdocuments.net/reader036/viewer/2022062516/56649d485503460f94a22d78/html5/thumbnails/11.jpg)
Acknowledgements:
A. P. Lee, PhD Jeffrey S. Fisher Wei-Yu (Tim) Tseng Undergraduate Research Opportunity
Program, UROP National Science Foundation, NSF