fact sheet - accessnsite...fact sheet accessnsite • 2520 skyway drive, suite a • santa maria, ca...
TRANSCRIPT
secure
Dual Reader Interface(2 readers, 8 inputs, 6 outputs)
Single Reader Interface(1 reader, 2 inputs, 2 outputs)
Single & Dual Reader Interface
FACT SHEET
AccessNsite • 2520 Skyway Drive, Suite A • Santa Maria, CA 93455 • accessnsite.com AN003 (06/2016)
accessnsite.com
Manage one or two doors
Features
The Single Reader Interface (SRI) and Dual Reader Interface (DRI)are low cost, high performance sub-controllers that provide theI/O necessary to control one or two doors, respectively. Support for readers, keypads, and readers with integrated keypads that use Wiegand, clock-and-data, or RS-485 signaling is provided.
Inputs and outputs can be assigned to door-related functions or as general purpose I/O. Inputs can be unsupervised or supervised using configurable end-of-line resistance values. Outputs are implemented using Form-C (normally open/normally closed) relays and can be used for fail-safe or fail-secure lock operation.
The SRI and DRI use a high speed, two-wire, multi-drop RS-485interface to communicate with the controller (ADC, IDC, or IDC-1)which resides on an Ethernet network. Events generated by the SRI or DRI can be used to trigger actions locally or on other sub-controllers attached to the same controller.
Access request, status change, command, and configuration information is exchanged with the controller. The controller is managed by a host computer using industry-leading AccessNsite® software, but runs independently when not communicating with the host.
• Supports wide array of card and reader technologies including Smart card, FIPS 201, proximity, biometric, and magnetic stripe
• Most widely accepted access control hardware due to its reliability and open architecture• Compatible across AccessNsite’s family of distributed controllers
• SRI has a small footprint• Supports up to 8 program-
mable card formats• 12 V to 24 V DC operation• Grade A input supervision• AES 128 bit encryption• Tamper input
• Fiel upgradable firmware• UL listed 294/1076• 1 year limited warranty
Single & Dual Reader Interface
FACT SHEET
AccessNsite • 2520 Skyway Drive, Suite A • Santa Maria, CA 93455 • accessnsite.com AN003 (06/2016)
accessnsite.com
Primary Power• 12 VDC to 24 VDC +/-
10%, 150 mA max (plus reader current)
Readers• 1 Port
Reader Power• Input voltage passed through
Relays• 1 Form-C, 5 A @ 30 VDC• 1 Form-C, 1 A @ 30 VDC
Inputs• 2 supervised• 1 dedicated for tamper
Dimensions• 4.25” W x 2.75” L x 1.0” H
Operating Temperature• -40º C to 75º C
Humidity• 10% to 95% RHNC
Primary Power• 12 VDC to 24 VDC +/-
10%, 550 mA max (plus reader current)
Readers• 2 Ports
Reader Power• Regulated 12 VDC or passed through, 125 mA max per port
Relays• 6 Relays, Form-C, 5 A @ 28 VDC
Inputs• 8 supervised• 2 dedicated: tamper & power fault
Dimensions• 6.0” W x 8.0” L x 1.0” H
Operating Temperature• 0ºC to 70ºC
Humidity• 0% to 95% RHNC
Storage Temperature• -55º C to 85º C
Reader Interface• One or two wire bi-color LED support• Buzzer (Only with “one-wire” LED)• TTL compatible inputs or 2-wire RS-485
Communication• RS-485, 2 wire, 4000’
Certifications• UL294, UL1076• CE• RoHS
SRI Specifications DRI Specifications Common Specifications
secure
ERI
MUX8
Controller
Network
OP16
IP16
SingleReader
Interface
DualReader
Interface
KRI
1 2 3 4 5 6 7 8J2
TB1GND
J3
J5
TR-
TR+
VO
D0DAT
GND
D1
LED
DAT
BZR
TB4
J4
B A
U1
J6
TB3
TB2
K2
K1
I1
I1
I2
I2
GND
VIN
C
NC
NO
C
NO
NC
K2K1
2.35
[59
.7]
2.75
[69
.9]
3.85 [97.8]
4.25 [108]
.2 [5.1]
.2 [5.1]
SRI DRI
STATU
S LE
Ds
J3
J5J6
SG
R-
R+
TR-
TR+
AC
DC
AC
GN
D IN1IN2IN3IN4IN5IN6IN7IN8
2W 4W
RS
485
GN
D
TMP
PFL
VO
LED
BZR
D1
D0
GN
D
NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC
RLY
1
RLY
2
RLY
3
RL Y
4
RLY
5
RLY
6
OFF O
N
8 7 6 5 4 3 2 1
VO
LED
BZR
D1
D0
GN
D
A B 1 2 3 4 5 6 7 8 TM
P PFL R
1 R2
J7J8
K1 K
2 K3 K
4 K5 K
6 J2
12V P
T
GN
D
5.50 [139.70]6.00 [152.40]
2.00 [50.80] 2.00 [50.80]3.00 [76.20]
8.00 [203.20]