fem pile foundation
TRANSCRIPT
-
8/13/2019 FEM Pile Foundation
1/1
CivilPark:ShortArticlesforDesignersSeriesModeling,AnalysisandDesignofMatonPileFoundations
Using2DPlate/ShellFiniteElementBasedModels
MainIssueAddressedinThisArticleCanwerelyon2D(Planar)FEmodel(suchasadoptedbyCSISAFEsoftware)for
findingthedesignreactionsonpilesanddesignactions(M,V)anddeflectionsofMat
onpile?
WhyThisArticle?Inlast56yearswehaveencounteredthisquestionmanytimes,practically,every
casethatwewereinvolvedinthedesignofbuildingprojectsthatincludepilematfoundationandthe
questionsrevolvedaroundtheoneshownonthefirstparagraph(above).
ShortAnswerBasedonourknowledgeofFiniteElementAnalysisanddesignexperiencewehavefound:
(1) 2DPlanarFEmodelforPileMatcantcapturethetrueshortandlongtermdistributionofsuperstructure load on pile through mat, though such analysis apparently maintains the
overallequilibriumofthesystem.Oneverycommoncasetojustifythispointisthat,with35
m thick mat on large bored piles (11.5m dia) @ 56m center to center, one easily gets
reactions (asanalysisoutput)onfouradjacentpiles intheorderof4,000;2,000,1,000and
500ton.
(2)As
the
vertical
reactions
on
piles
are
not
correct,
same
will
be
the
case
with
the
moment
andshearforcesproducedonthemat(modeledasplate/shell).Wecaneasilyunderstandthis
pointjustbycomparingtheonestripofmatasmultispanbeamusingthesimplelogicthat
Moments&ShearscantbecorrectunlessReactionsarecorrect(EquilibriumLaw).
ShortExplanations(1) Quick reviewof the fundamental formulationof FiniteElements, theplate/shell in thiscase, one can easily identify that these elements are not developed or meant to model
thick/deepstructureslikeTransferGirder,PileCaps,MatFoundationsandso.
(2)Bydefinition theplate/shellelementsaresuitable tomodel that situationwhere the inplanedimensions are significantly larger (say in theorderof 4or above) than the vertical
dimension.Incurrentcase,thehorizontaldimensionsarenotthefullsizeofthematbutthe
piletopiledistancesandtheverticaldimensionisthematthickness.
SolutionsSolid element based model of mat, with proper accountability of superstructure contribution, non
conventionalmodelingofpiles(springs)andincrementalloading(allowingforloadredistribution)isabetter
solution.Wehavetriedthisapproachinsomeofourprojectsinthepastandfoundtoperformwell&feasible
(practical).OneofearlyapplicationofsuchapproachisFullertonBuilding(37Story,Sukhumvit67,Bangkok).
Yourquestions,comments,experiencesharing,feedbackaremostwelcome:[email protected]@civilpark.com
BuddhiS.
SudaT.