Rev#11 1-10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information Name of Property: Street Address: City: Property Representative: Street Address: City: Phone: State: Zip: State: Annual Quarterly Zip: Email: Comments Customer Name: Inspector Name: Customer Signature: Inspector Signature: Results: Semi-Annually Fire Department: Type of Inspection: 1/25/2019 08:00 Marco Island (239) 389-3600 FL Vintage Bay 133, 201, 269, and 337 Vintage Bay Dr Marco Island FL 34145 Volhr Corporation 979 North Collier Blvd. 34145 maintenance@volhrcorporat Impairment Marco Island 1) Fire pump does not start when pressure is lost down to 0 under controller. In manual mode the manual crank 1 doesn’t start pump, crank 2 started pump. The stop button didn’t stop run. 2) The PIV is damaged and needs repaired, also valve is not locked sealed or supervised. 3) The fuel tank for the fire pump is not at least 2/3rds full. Christopher Yancey

Upload: others

Post on 06-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Rev#11 1-10-18 Page 1 of 4

Fire Sprinkler Testing and Inspection Report

Date and Time of Inspection:

Property InformationName of Property:

Street Address:City:

Property Representative: Street Address:

City:Phone:

State: Zip:

State:

Annual Quarterly

Zip:Email:

Comments

Customer Name:

Inspector Name:

Customer Signature:

Inspector Signature:

Results:

Semi-Annually

Fire Department:

Type of Inspection:

1/25/2019 08:00

Marco Island

(239) 389-3600

FL

Vintage Bay

133, 201, 269, and 337 Vintage Bay Dr

Marco Island FL 34145

Volhr Corporation

979 North Collier Blvd.

34145

[email protected]

ImpairmentMarco Island

1) Fire pump does not start when pressure is lost down to 0 under controller. In manual mode the manual crank 1 doesn’t start pump, crank 2 started pump. The stop button didn’t stop run.2) The PIV is damaged and needs repaired, also valve is not locked sealed or supervised. 3) The fuel tank for the fire pump is not at least 2/3rds full.

Christopher Yancey

Page 2: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Quarterly

Normal water pressure maintained?

In the correct (open or closed) position?

Control Valves

Sealed, locked, or supervised?

Accessible?

Free from damage or leaks?

Proper signage?

Pumps (See Chapter 8 of NFPA 25)

Is fire pump

Fire Department Connections

Location

Wet Systems

Is building adequately heated?

Is system hydraulically calculated?

If yes, is hydraulic information sign provided at valve?

Diesel Electric Gasoline None

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Valves closed and reopened?Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

General

Building

Location of sprinkler valve

Type of sprinkler system

Make and model of sprinkler valve

Hydraulic Calculation Plate is Secure and Legible:

Location of Hydraulic Calculation Plate:

Have all deficiencies reported at last inspection corrected?

Prior inspection reports available for review?

Wet Dry Deluge Preaction

Valves

How are valves supervised?

Are valves identified with signs?

Sealed Locked Tamper Switch

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Tested or Replaced within 5-year Interval?Yes No N/A

Supervisory switches send signals to fire panel?Yes No N/A

INSPECTIONS

Type:

Backflow Preventer

Yes No N/ARelief valve on RP type not showing discharge?

Gauges

Page 2 of 4Rev#11 1-10-18

Condominium

Pump room/ stairwell

OS&Y valve/ butterfly valve

Riser in stairwell

Front of building

RP

Page 3: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Pressure Reducing Valve

Maintaining downstream pressure?

Quarterly

Static

PSI

Residual

PSI

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Alarm Devices free of damage?

Hydraulic data nameplate securely attached to riser / legible?

Visible and accessible?

Fire Department Connections

Coupling / swivels operate corectly?

Plugs / caps are in place?

Interior inspected where caps missing?

Gaskets are not damaged?

Identification signs are in place?

Ball drip valve is functional?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Check valve is free of leaks?Yes No N/A

Water flow alarm activated within five minutes?

Alarm Devices

Accessible?

Retard chamber / alarm drains not leaking?

Yes No

Yes No N/A

Yes No N/A

Water Gong Vane Type?

Returned

Static

Yes No N/A

Yes No N/A

Inspectors test / bypass opened?Yes No N/A

In the open position / not leaking?

In good condition?

Alarm devices, water motor gong activated?

Do results difer by more than 10% from previous test?

Fire pump was temporarily turned off?

Backflow preventer -Test?

Backflow preventer - Flow test?

Main drain test, if the sole supply is through a backflow.

Page 3 of 4

N/A

Rev#11 1-10-18

Page 4: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

No damage or leaks?

Free of corrosion, foreign material, paint?

Installed in proper orientation?

Sprinkler spray pattern appear free of unacceptable obstructions?

Hangers and seismic bracing not damaged or loose?

Escutcheons are not missing, painted or rusted?

Spare sprinkler cabinet provided?

Cabinet has proper number and type of spares?

Cabinet has proper wrench for each type provided?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Cabinet location temperature does not exceed over 100 degrees?Yes No N/A

In good condition/No external corrosion?

No leaks or mechanical damage?

Correct alignment/No external loads?

Building wet piping not exposed to freezing temps?

Hoses/Hose racks inspected per NFPA 1962?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Fire Pump

Started Automatically?

Diesel pump ran for 30 minutes?

Electric pump ran for 10 minutes?

Diesel engine fuel tank is at least 2/3rd's full?

Packing glands showing proper discharge?

Pump is in good condition?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Sprinklers (visible)

Pipe & Fittings (visible)

Fire sprinkler tested per appropriate testing schedule?Yes No N/A

Page 4 of 4Rev#11 1-10-18

Page 5: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Rev#11 1-10-18 Page 1 of 4

Fire Sprinkler Testing and Inspection Report

Date and Time of Inspection:

Property InformationName of Property:

Street Address:City:

Property Representative: Street Address:

City:Phone:

State: Zip:

State:

Annual Quarterly

Zip:Email:

Comments

Customer Name:

Inspector Name:

Customer Signature:

Inspector Signature:

Results:

Semi-Annually

Fire Department:

Type of Inspection:

1/25/2019 08:00

Marco Island

(239) 389-3600

FL

Vintage Bay

201 Vintage Bay Dr

Marco Island FL 34145

Volhr Corporation

979 North Collier Blvd.

34145

[email protected]

ImpairmentMarco Island

1) Fire pump does not start when pressure is lost down to 0 under controller. In manual mode the manual crank 1 doesn’t start pump, crank 2 started pump. The stop button didn’t stop run2) The calculations plate is faded and needs to be replaced.

Christopher Yancey

Page 6: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Quarterly

Normal water pressure maintained?

In the correct (open or closed) position?

Control Valves

Sealed, locked, or supervised?

Accessible?

Free from damage or leaks?

Proper signage?

Pumps (See Chapter 8 of NFPA 25)

Is fire pump

Fire Department Connections

Location

Wet Systems

Is building adequately heated?

Is system hydraulically calculated?

If yes, is hydraulic information sign provided at valve?

Diesel Electric Gasoline None

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Valves closed and reopened?Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

General

Building

Location of sprinkler valve

Type of sprinkler system

Make and model of sprinkler valve

Hydraulic Calculation Plate is Secure and Legible:

Location of Hydraulic Calculation Plate:

Have all deficiencies reported at last inspection corrected?

Prior inspection reports available for review?

Wet Dry Deluge Preaction

Valves

How are valves supervised?

Are valves identified with signs?

Sealed Locked Tamper Switch

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Tested or Replaced within 5-year Interval?Yes No N/A

Supervisory switches send signals to fire panel?Yes No N/A

INSPECTIONS

Type:

Backflow Preventer

Yes No N/ARelief valve on RP type not showing discharge?

Gauges

Page 2 of 4Rev#11 1-10-18

Condominium

Stairwell

Butterfly valve

Riser

Front of building

RP

Page 7: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Pressure Reducing Valve

Maintaining downstream pressure?

Quarterly

Static

PSI

Residual

PSI

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Alarm Devices free of damage?

Hydraulic data nameplate securely attached to riser / legible?

Visible and accessible?

Fire Department Connections

Coupling / swivels operate corectly?

Plugs / caps are in place?

Interior inspected where caps missing?

Gaskets are not damaged?

Identification signs are in place?

Ball drip valve is functional?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Check valve is free of leaks?Yes No N/A

Water flow alarm activated within five minutes?

Alarm Devices

Accessible?

Retard chamber / alarm drains not leaking?

Yes No

Yes No N/A

Yes No N/A

Water Gong Vane Type?

Returned

Static

Yes No N/A

Yes No N/A

Inspectors test / bypass opened?Yes No N/A

In the open position / not leaking?

In good condition?

Alarm devices, water motor gong activated?

Do results difer by more than 10% from previous test?

Fire pump was temporarily turned off?

Backflow preventer -Test?

Backflow preventer - Flow test?

Main drain test, if the sole supply is through a backflow.

Page 3 of 4

N/A

Rev#11 1-10-18

Page 8: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

No damage or leaks?

Free of corrosion, foreign material, paint?

Installed in proper orientation?

Sprinkler spray pattern appear free of unacceptable obstructions?

Hangers and seismic bracing not damaged or loose?

Escutcheons are not missing, painted or rusted?

Spare sprinkler cabinet provided?

Cabinet has proper number and type of spares?

Cabinet has proper wrench for each type provided?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Cabinet location temperature does not exceed over 100 degrees?Yes No N/A

In good condition/No external corrosion?

No leaks or mechanical damage?

Correct alignment/No external loads?

Building wet piping not exposed to freezing temps?

Hoses/Hose racks inspected per NFPA 1962?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Fire Pump

Started Automatically?

Diesel pump ran for 30 minutes?

Electric pump ran for 10 minutes?

Diesel engine fuel tank is at least 2/3rd's full?

Packing glands showing proper discharge?

Pump is in good condition?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Sprinklers (visible)

Pipe & Fittings (visible)

Fire sprinkler tested per appropriate testing schedule?Yes No N/A

Page 4 of 4Rev#11 1-10-18

Page 9: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Rev#11 1-10-18 Page 1 of 4

Fire Sprinkler Testing and Inspection Report

Date and Time of Inspection:

Property InformationName of Property:

Street Address:City:

Property Representative: Street Address:

City:Phone:

State: Zip:

State:

Annual Quarterly

Zip:Email:

Comments

Customer Name:

Inspector Name:

Customer Signature:

Inspector Signature:

Results:

Semi-Annually

Fire Department:

Type of Inspection:

1/25/2019 08:00

Marco Island

(239) 389-3600

FL

Vintage Bay

269 Vintage Bay Dr

Marco Island FL 34145

Volhr Corporation

979 North Collier Blvd.

34145

[email protected]

ImpairmentMarco Island

1) Control valve in pump room is not locked sealed or supervised. 2) FDC is not accessible/ visible. 3) Fire Pump want start

Christopher Yancey

Page 10: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Quarterly

Normal water pressure maintained?

In the correct (open or closed) position?

Control Valves

Sealed, locked, or supervised?

Accessible?

Free from damage or leaks?

Proper signage?

Pumps (See Chapter 8 of NFPA 25)

Is fire pump

Fire Department Connections

Location

Wet Systems

Is building adequately heated?

Is system hydraulically calculated?

If yes, is hydraulic information sign provided at valve?

Diesel Electric Gasoline None

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Valves closed and reopened?Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

General

Building

Location of sprinkler valve

Type of sprinkler system

Make and model of sprinkler valve

Hydraulic Calculation Plate is Secure and Legible:

Location of Hydraulic Calculation Plate:

Have all deficiencies reported at last inspection corrected?

Prior inspection reports available for review?

Wet Dry Deluge Preaction

Valves

How are valves supervised?

Are valves identified with signs?

Sealed Locked Tamper Switch

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Tested or Replaced within 5-year Interval?Yes No N/A

Supervisory switches send signals to fire panel?Yes No N/A

INSPECTIONS

Type:

Backflow Preventer

Yes No N/ARelief valve on RP type not showing discharge?

Gauges

Page 2 of 4Rev#11 1-10-18

Condominium

Pump room/ Stairwell

Butterfly valve

Riser in stairwell

Front of building

RP

Page 11: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Pressure Reducing Valve

Maintaining downstream pressure?

Quarterly

Static

PSI

Residual

PSI

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Alarm Devices free of damage?

Hydraulic data nameplate securely attached to riser / legible?

Visible and accessible?

Fire Department Connections

Coupling / swivels operate corectly?

Plugs / caps are in place?

Interior inspected where caps missing?

Gaskets are not damaged?

Identification signs are in place?

Ball drip valve is functional?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Check valve is free of leaks?Yes No N/A

Water flow alarm activated within five minutes?

Alarm Devices

Accessible?

Retard chamber / alarm drains not leaking?

Yes No

Yes No N/A

Yes No N/A

Water Gong Vane Type?

Returned

Static

Yes No N/A

Yes No N/A

Inspectors test / bypass opened?Yes No N/A

In the open position / not leaking?

In good condition?

Alarm devices, water motor gong activated?

Do results difer by more than 10% from previous test?

Fire pump was temporarily turned off?

Backflow preventer -Test?

Backflow preventer - Flow test?

Main drain test, if the sole supply is through a backflow.

Page 3 of 4

N/A

Rev#11 1-10-18

Page 12: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

No damage or leaks?

Free of corrosion, foreign material, paint?

Installed in proper orientation?

Sprinkler spray pattern appear free of unacceptable obstructions?

Hangers and seismic bracing not damaged or loose?

Escutcheons are not missing, painted or rusted?

Spare sprinkler cabinet provided?

Cabinet has proper number and type of spares?

Cabinet has proper wrench for each type provided?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Cabinet location temperature does not exceed over 100 degrees?Yes No N/A

In good condition/No external corrosion?

No leaks or mechanical damage?

Correct alignment/No external loads?

Building wet piping not exposed to freezing temps?

Hoses/Hose racks inspected per NFPA 1962?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Fire Pump

Started Automatically?

Diesel pump ran for 30 minutes?

Electric pump ran for 10 minutes?

Diesel engine fuel tank is at least 2/3rd's full?

Packing glands showing proper discharge?

Pump is in good condition?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Sprinklers (visible)

Pipe & Fittings (visible)

Fire sprinkler tested per appropriate testing schedule?Yes No N/A

Page 4 of 4Rev#11 1-10-18

Page 13: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Rev#11 1-10-18 Page 1 of 4

Fire Sprinkler Testing and Inspection Report

Date and Time of Inspection:

Property InformationName of Property:

Street Address:City:

Property Representative: Street Address:

City:Phone:

State: Zip:

State:

Annual Quarterly

Zip:Email:

Comments

Customer Name:

Inspector Name:

Customer Signature:

Inspector Signature:

Results:

Semi-Annually

Fire Department:

Type of Inspection:

1/25/2019 08:00

Marco Island

(239) 389-3600

FL

Vintage Bay

337 Vintage Bay Dr

Marco Island FL 34145

Volhr Corporation

979 North Collier Blvd.

34145

[email protected]

ImpairmentMarco Island

1) The trash room tamper valve is not identified. Need to place sign on ceiling to identify valve. Valve is located in the lobby area. 2) Fire Pump want start.

Christopher Yancey

Page 14: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Quarterly

Normal water pressure maintained?

In the correct (open or closed) position?

Control Valves

Sealed, locked, or supervised?

Accessible?

Free from damage or leaks?

Proper signage?

Pumps (See Chapter 8 of NFPA 25)

Is fire pump

Fire Department Connections

Location

Wet Systems

Is building adequately heated?

Is system hydraulically calculated?

If yes, is hydraulic information sign provided at valve?

Diesel Electric Gasoline None

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Valves closed and reopened?Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

General

Building

Location of sprinkler valve

Type of sprinkler system

Make and model of sprinkler valve

Hydraulic Calculation Plate is Secure and Legible:

Location of Hydraulic Calculation Plate:

Have all deficiencies reported at last inspection corrected?

Prior inspection reports available for review?

Wet Dry Deluge Preaction

Valves

How are valves supervised?

Are valves identified with signs?

Sealed Locked Tamper Switch

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Tested or Replaced within 5-year Interval?Yes No N/A

Supervisory switches send signals to fire panel?Yes No N/A

INSPECTIONS

Type:

Backflow Preventer

Yes No N/ARelief valve on RP type not showing discharge?

Gauges

Page 2 of 4Rev#11 1-10-18

Condominium

Side of building / Stairwell

PIV/ butterfly valve

Riser

Side of building

RP

Page 15: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

Pressure Reducing Valve

Maintaining downstream pressure?

Quarterly

Static

PSI

Residual

PSI

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Alarm Devices free of damage?

Hydraulic data nameplate securely attached to riser / legible?

Visible and accessible?

Fire Department Connections

Coupling / swivels operate corectly?

Plugs / caps are in place?

Interior inspected where caps missing?

Gaskets are not damaged?

Identification signs are in place?

Ball drip valve is functional?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Check valve is free of leaks?Yes No N/A

Water flow alarm activated within five minutes?

Alarm Devices

Accessible?

Retard chamber / alarm drains not leaking?

Yes No

Yes No N/A

Yes No N/A

Water Gong Vane Type?

Returned

Static

Yes No N/A

Yes No N/A

Inspectors test / bypass opened?Yes No N/A

In the open position / not leaking?

In good condition?

Alarm devices, water motor gong activated?

Do results difer by more than 10% from previous test?

Fire pump was temporarily turned off?

Backflow preventer -Test?

Backflow preventer - Flow test?

Main drain test, if the sole supply is through a backflow.

Page 3 of 4

N/A

Rev#11 1-10-18

Page 16: Fire Sprinkler Testing and Inspection Report...2019/01/25  · Rev#11 1 -10-18 Page 1 of 4 Fire Sprinkler Testing and Inspection Report Date and Time of Inspection: Property Information

No damage or leaks?

Free of corrosion, foreign material, paint?

Installed in proper orientation?

Sprinkler spray pattern appear free of unacceptable obstructions?

Hangers and seismic bracing not damaged or loose?

Escutcheons are not missing, painted or rusted?

Spare sprinkler cabinet provided?

Cabinet has proper number and type of spares?

Cabinet has proper wrench for each type provided?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Cabinet location temperature does not exceed over 100 degrees?Yes No N/A

In good condition/No external corrosion?

No leaks or mechanical damage?

Correct alignment/No external loads?

Building wet piping not exposed to freezing temps?

Hoses/Hose racks inspected per NFPA 1962?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Fire Pump

Started Automatically?

Diesel pump ran for 30 minutes?

Electric pump ran for 10 minutes?

Diesel engine fuel tank is at least 2/3rd's full?

Packing glands showing proper discharge?

Pump is in good condition?

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Yes No N/A

Sprinklers (visible)

Pipe & Fittings (visible)

Fire sprinkler tested per appropriate testing schedule?Yes No N/A

Page 4 of 4Rev#11 1-10-18