  • Prepared By Operations Division April 2, 2007

    Prepared By Operations Division April 2, 2007

    FIREFIGHTERNEAR MISSAuto Fire with

    Compressed Natural Gas(CNG) Fuel Tank Explosion

    FIREFIGHTERNEAR MISSAuto Fire with

    Compressed Natural Gas(CNG) Fuel Tank Explosion

  • Seattle Fire Department22

    Arson: Incident #26564 Arson: Incident #26564

    • Dispatch 0230 hours for car fire (E10)• E10 arrived and requested FIB for multiple

    vehicles with possible structural exposures (freeway columns and overpasses)

    • 12 vehicles damaged or destroyed • Firefighter near miss when CNG vehicle

    exploded as E10 crew approached with a handline (approximately 50-75’ away)

    • Dispatch 0230 hours for car fire (E10)• E10 arrived and requested FIB for multiple

    vehicles with possible structural exposures (freeway columns and overpasses)

    • 12 vehicles damaged or destroyed • Firefighter near miss when CNG vehicle

    exploded as E10 crew approached with a handline (approximately 50-75’ away)

  • Seattle Fire Department33

    FireGarage

    FireFireGarageGarage

  • Seattle Fire Department44

    Royal B

    rougha

    m

    Royal B

    rougha

    m88t

    hthA

    ve S

    outh

    Ave

    Sou

    th

    Access GateAccess GateAccess Gate

    E10

    E10

    E10

  • Seattle Fire Department55

    E10 parked outsidethe gate hereE10 parked outsideE10 parked outsidethe gate herethe gate here

    Debris from the explosion was thrown up to 100’ in all directions including on the over-

    passes above the incident.

    Debris from the explosion was thrown up to Debris from the explosion was thrown up to 100’ in all directions including on the over100’ in all directions including on the over--

    passes above the incident.passes above the incident.

  • Seattle Fire Department66

    ++++++++++++

    BackhoeBackhoeBackhoe

    Fuel tank(original location)Fuel tankFuel tank(original location)(original location)

    Trunk lidTrunk lidTrunk lidBumper frameBumper frameBumper frame

    Roof debrisRoof debrisRoof debris

    Roof debrisRoof debrisRoof debris

    100’

  • Seattle Fire Department77

    Honda CNG VehicleHonda CNG Vehicle

  • Seattle Fire Department88

  • Seattle Fire Department99

    Rear of vehicleRear of vehicle

  • Seattle Fire Department1010

    Roof is blown completelyRoof is blown completelyoff vehicle and doors blownoff vehicle and doors blownopenopen

  • Seattle Fire Department1111

  • Seattle Fire Department1212

  • Seattle Fire Department1313

  • Seattle Fire Department1414

  • Seattle Fire Department1515

    Metal mountingstraps for CNG tank

    Metal mountingMetal mountingstraps for CNG tankstraps for CNG tank

  • Seattle Fire Department1616

    Trunk lidTrunk lidTrunk lid

  • Seattle Fire Department1717

    Tank landed here,moved down hill to herefor extinguishment

    Tank landed here,Tank landed here,moved down hill to heremoved down hill to herefor extinguishmentfor extinguishment

  • Seattle Fire Department1818

    Rear bumper frame 90’+ awayRear bumper frame 90’+ away

  • Seattle Fire Department1919

    Bumper shrapnelBumper shrapnelNote burn marks onNote burn marks onground. ground.

  • Seattle Fire Department2020

    Roof section about 75’ awayRoof section about 75’ awayRoof section about 75’ away

  • Seattle Fire Department2121

    This is your only warning ofa CNG – fueled vehicle. Typically located on the trunk lid or bumper

    This is your only warning ofThis is your only warning ofa CNG a CNG –– fueled vehicle. Typically fueled vehicle. Typically located on the trunk lid or bumperlocated on the trunk lid or bumper

  • Seattle Fire Department2222

  • Seattle Fire Department2323

    Composite tank is carbon-fiber / fiberglasswrapped for strength – similar to our SCBA tanks.Composite tank is carbonComposite tank is carbon--fiber / fiberglassfiber / fiberglasswrapped for strength wrapped for strength –– similar to our SCBA tanks.similar to our SCBA tanks.

  • Seattle Fire Department2424

  • Seattle Fire Department2525

  • Seattle Fire Department2626

  • Seattle Fire Department2727

  • Seattle Fire Department2828

    Tank blown approximately95’ from the vehicle

    Tank blown approximatelyTank blown approximately95’ from the vehicle95’ from the vehicle

  • Seattle Fire Department2929

  • Seattle Fire Department3030

    August 07, 2003

    Airport Taxis, Shuttles Convert to Natural GasNew contract requires fleet conversions to improve air quality

    The Port of Seattle Commission today authorized the renewal of contracts with two major providers of ground transportation at Seattle-Tacoma International Airport. The contracts, with the Seattle Tacoma International Taxi Association (STITA) and Shuttle Express, will require the two organizations to make major investments toconvert their fleets to clean-burning natural gas.

    Under its new contract, STITA will be required to convert its entire 160-cab fleet to natural gas in the next three years. By converting more quickly, STITA will earn the right to extend the contract from five to seven years.

  • Seattle Fire Department3131

    Historical InformationHistorical Information

    • Several NHTSA (National Highway Traffic Safety Administration) investigations– Example: January 27, 2003; Ford Crown

    Victoria on fire with flame impingement on CNG tank. The tank failed catastrophically prior to Pressure Relief Device (PRD) functioning.

    – Vehicle recall with dealers installing additional insulation behind back seat.

    – Number of vehicles still needing repair???

    • Several NHTSA (National Highway Traffic Safety Administration) investigations– Example: January 27, 2003; Ford Crown

    Victoria on fire with flame impingement on CNG tank. The tank failed catastrophically prior to Pressure Relief Device (PRD) functioning.

    – Vehicle recall with dealers installing additional insulation behind back seat.

    – Number of vehicles still needing repair???

  • Seattle Fire Department3232

    Code of Federal RegulationsCode of Federal Regulations

    • CFR 49, Part 571– Standard 304

    Compressed Natural Gas Fuel Container Integrity

    Flame Test Standard:Flame impingement generating 1550-1650° F. at the surface for the length of the cylinder for 20 minutes or until fuel is completely vented through PRV.

    • CFR 49, Part 571– Standard 304

    Compressed Natural Gas Fuel Container Integrity

    Flame Test Standard:Flame impingement generating 1550-1650° F. at the surface for the length of the cylinder for 20 minutes or until fuel is completely vented through PRV.

  • Seattle Fire Department3333

    CNG PropertiesCNG Properties

    • Compressed to 3,600 psi in fuel cylinder• CNG rated at 117 octane fuel• BTU per # = 22,800 (gasoline = 18,900)• Not a liquid when compressed (it becomes

    a very close dense gas)• Not the same as Liquified Natural Gas –

    LNG (cryogenic: -260° to become liquified)• Lighter than air when released ( .6 air)

    • Compressed to 3,600 psi in fuel cylinder• CNG rated at 117 octane fuel• BTU per # = 22,800 (gasoline = 18,900)• Not a liquid when compressed (it becomes

    a very close dense gas)• Not the same as Liquified Natural Gas –

    LNG (cryogenic: -260° to become liquified)• Lighter than air when released ( .6 air)

  • Seattle Fire Department3434

    CNG PropertiesCNG Properties

    • LEL / UEL = 4 – 16% (gasoline = 1.3 – 7.6)• 1 cubic foot of CNG = 245 cu.ft. of natural

    gas at sea level (uncompressed)• 1 cubic foot of CNG weighs 13#• 5.66# = 1 Gasoline Gallon Equivalent (GGE)• Honda Civic tank = 8 GGE• Note: 1 gallon of gasoline properly vaporized has

    the explosive equivalency of 83 pounds of dynamite (CDC).

    • LEL / UEL = 4 – 16% (gasoline = 1.3 – 7.6)• 1 cubic foot of CNG = 245 cu.ft. of natural

    gas at sea level (uncompressed)• 1 cubic foot of CNG weighs 13#• 5.66# = 1 Gasoline Gallon Equivalent (GGE)• Honda Civic tank = 8 GGE• Note: 1 gallon of gasoline properly vaporized has

    the explosive equivalency of 83 pounds of dynamite (CDC).

  • Seattle Fire Department3535

    Cylinder PropertiesCylinder Properties

    • Four Cylinder Types:– Type 1: all metal (steel or aluminum)– Type 2: hoop wrapped steel or aluminum– Type 3: fully wrapped steel or aluminum– Type 4: all-composite (non-metallic)*

    *Early model Honda Civic uses Type 4;later models use Type 3

    • Four Cylinder Types:– Type 1: all metal (steel or aluminum)– Type 2: hoop wrapped steel or aluminum– Type 3: fully wrapped steel or aluminum– Type 4: all-composite (non-metallic)*

    *Early model Honda Civic uses Type 4;later models use Type 3

  • Seattle Fire Department3636

    Honda Civic Tank DesignHonda Civic Tank Design

  • Seattle Fire Department3737

    Honda Civic Tank DesignHonda Civic Tank Design

    Note: The PRD (pressure relief device) activates similar to a fusible link (it fails versus resealing like a spring-assisted pressure reducing valve –PRV). The gas is vented out the vent tube until the tank is empty. Discharge time depends on fuel level.

    Note: The PRD (pressure relief device) activates similar to a fusible link (it fails versus resealing like a spring-assisted pressure reducing valve –PRV). The gas is vented out the vent tube until the tank is empty. Discharge time depends on fuel level.

  • Seattle Fire Department3838

    Lessons Learned /Best PracticesLessons Learned /Best Practices• Approach from 45° angle to vehicle ends• Be aware of CNG vehicles

    – Cabs, city vehicles, shuttles• Look for CNG placards• Watch for other hazards, i.e. bumper

    struts; hood and tailgate struts; airbags; burning fuel runoff; hazardous vehicle contents; exploding tires; other traffic

    • Consider cooling streams from a distance

    • Approach from 45° angle to vehicle ends• Be aware of CNG vehicles

    – Cabs, city vehicles, shuttles• Look for CNG placards• Watch for other hazards, i.e. bumper

    struts; hood and tailgate struts; airbags; burning fuel runoff; hazardous vehicle contents; exploding tires; other traffic

    • Consider cooling streams from a distance

    FIREFIGHTERNEAR MISS Auto Fire withCompressed Natural Gas(CNG) Fuel Tank ExplosionArson: Incident #26564Historical InformationCode of Federal RegulationsCNG PropertiesCNG PropertiesCylinder PropertiesHonda Civic Tank DesignHonda Civic Tank DesignLessons Learned /Best Practices