Food Service Technology Center
Vulcan VCCG36-AR01 Gas Griddle Test Report FSTC Report # 501311462-R0
Application of ASTM Standard Test Method F1275-03 (Reapproved 2008) January 2016
Prepared by: Andre Hookfin Fisher-Nickel, Inc. Contributors: Rodney Davis Denis Livchak Fisher-Nickel, Inc.
Prepared for: Pacific Gas and Electric Company
Customer Energy Efficiency Programs PO Box 770000
San Francisco, California 94177 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2016
FSTC Equipment Test Report
ECP 160104
Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since 1987. The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility.
The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor.
Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, Inc. and the FSTC do not endorse particular products or services from any specific manufacturer or service provider.
The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation.
The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC.
FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws.
Disclaimer Copyright 2016 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Fisher-Nickel, Inc., PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights.
Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Fisher-Nickel, Inc., the FSTC, or PG&E. In no event will Fisher-Nickel, Inc. or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report.
Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project.
Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report.
Revision History
Revision num. Date Description Author(s)
0 Jan 2016 Initial Release A. Hookfin
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 2 of 12
FSTC Equipment Test Report
ECP 160104
Contents Page
Equipment Description ………………………………………………………………………………………. 4
Test Location …………………………………………………………………………………………………… 4
Ventilation ………………………………………………………………………………………………………. 4
Test Instrumentation Inventory …………………………………………………………………………….. 5
FSTC Test Report: Results ………………………………………………………………………………….. 6
Additions, Deviations, and Exclusions …………………………………………………………………… 8
ENERGY STAR® Qualification …………………………………………………………………………….. 9
Manufacturer Specifications Sheet ………………………………………………………………………... 10
Report Certification ………………………………………………………………………………………….. 12
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 3 of 12
FSTC Equipment Test Report
ECP 160104
Test Location
All testing was performed under controlled conditions in the FSTC laboratory facilities at 12949 Alcosta
Blvd., Suite 101, San Ramon, CA 94583.
Ventilation
FSTC researchers installed the equipment on a tiled floor under a four-foot-deep canopy hood, which operated
at a nominal exhaust rate of 300 cfm per linear foot. The hood was mounted six feet, six inches above the
floor, with at least six inches of clearance between the vertical plane of the equipment and the hood’s edge.
Equipment Description
Test Work Order Number (TWO) 11462
Manufacturer Vulcan
Model VCCG36-AR01
Serial Number 6501358337
Generic Equipment Type Gas Griddle
Rated Input 90,000 Btu/h
Construction Stainless Steel; Chrome Griddle Plate; Atmospheric Burners
Controls Milivolt Thermostatic Controls
External Dimensions (W x D x H) 36" x 24" x 14.7"
Custom Settings (if any) None
Cooking Surface Dimensions (W x D) 36" x 24"
Nominal Griddle Width 3'
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 4 of 12
FSTC Equipment Test Report
ECP 160104
Thermocouple Inventory
Set Number Validation Date
45 11/10/2015
Holding Equipment Inventory
Description (ID) Manufacturer Model
Walk-In Freezer (FSTC-F-001) NorLake KLX
Test Instrumentation Inventory
Description (ID) Manufacturer Model Measurement Range
Resolution Calibration Date
Next Calibration
Gas Meter (ALE504) Sensus R-275 0 – 275 CFH 0.05 ft³ 02/17/2015 02/17/2016
Electric Meter (ALC305) Radian Research Metronic RM-10 0.2 – 50A 0.00001 Wh 02/17/2015 02/17/2016
DAQ Temp (ALE510) National Instruments FP-TC-120 0 – 1000°F 0.1°F 08/12/2014 08/12/2016
DAQ Pulse (ALE510) National Instruments FP-CTR-500 0 – 50,000 pulses/s 1 pulse 08/12/2014 08/12/2016
Digital Scale (ALB203) Mettler SB16001 0 – 35.5 lb 0.0005 lb 11/14/2015 11/14/2016
Thermometer (ALD402) Fluke 52 -40°F – 500°F 0.1°F 08/11/2015 08/11/2016
Barometer (ALD410) Davis Instruments 6163 16.00 – 32.50 inHg 0.01 inHg 06/12/2015 06/12/2016
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 5 of 12
FSTC Equipment Test Report SG CRT 151028
FSTC Test Report: Results
Purpose of Testing
Energy Input Rate Equipment Manifold Pressure (in. wc) 4.0Rated Energy Input Rate (Btu/h) 90,000Measured Energy Input Rate (Btu/h) 92,700Difference (%) 3.0
Preheat to 350°FAmbient Temperature (°F) 72.4Duration (min) 13.47Gas Energy Consumption (Btu) 20,330Control Energy Consumption (Wh) 6Preheat Rate (°F/min) 21
Idle Energy RateGriddle Cooking Surface Area (ft²) 6.00 Nameplate Information:Ambient Temperature (°F) 73.6Idle Temperature (°F) 376Gas Idle Energy Rate (Btu/h) 12,843Control Energy Rate (W) 170Normalized Idle Energy Rate (Btu/h/ft²) 2,141
Heavy-Load Cooking Energy Efficiency* Ambient Temperature (°F) 72.8
Food Product 1/4 lb 80/20 Beef
PattiesNumber of Burger Patties per load 24Cook Time (min) 5.85Average Recovery Time (sec) 85Gas Cooking Energy Rate (Btu/h) 57,815Control Energy Rate (kW) 0.220Energy to Food (Btu/lb) 449 VulcanEnergy to Equipment (Btu/lb) 1,162 3600 North Point Blvd.Cooking Energy Efficiency (%) 38.6 ± 1.2 Balitimore, MD , 21222Production Capacity (lb/h) 50.4 ± 0.7 www.vulcanequipment.com*Based on a minimum of three test replicates
This testing determined the energy input rate, preheat time and energy, idle energy rate, heavy-load cooking efficiency and production capacity of the griddle by applying the ASTM Standard Test Method F1275-03.
Vulcan VCCG36-AR01 Gas Griddle
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 6 of 12
FSTC Equipment Test Report SG CRT 151028
FSTC Test Report: Results
Gas Griddle
Standing Pilot Energy RateNA
Heavy-Load Cooking Test DataMeasured Values Test #1 Test #2 Test #3Test Date 12/14/15 12/14/15 12/15/15Total Hamburger Pattie Count 144 144 144Ambient Temperature (°F) 72.9 71.5 74.1Initial Weight of Hamburger Patties (lb) 36.490 36.510 36.770Final Weight of Hamburger Patties (lb) 23.005 23.450 24.560Initial Temperature of Hamburger Patties (°F) 0 0 0Final Temperature of Hamburger Patties (°F) 168 165 158Initial Moisture Content of Hamburger Patties (%) 59.1% 59.1% 59.1%Final Moisture Content of Hamburger Patties (%) 52.0% 51.1% 53.3%Fat Content Hamburger Patties (%) 20.3% 20.3% 20.3%Cook Time (min) 5.80 5.83 5.92Test Time (min) 43.68 43.28 43.72Test Voltage (V) 120 120 120Electric Energy Consumption (Wh) 160 160 158Gas Energy Consumption (Btu) 43,241 43,138 39,526Gas Heating Value (Btu/scf) 1,032 1,032 1,032
Calculated ValuesAverage Hamburger Patty Weight Loss (%) 37.0 35.8 33.2Specific Heat of Hamburger Patties (Btu/lb °F) 0.720 0.720 0.720Sensible Energy (Btu) 4,414 4,337 4,183Latent Fusion Energy (Btu) 3,105 3,107 3,129Latent Vaporization Energy (Btu) 9,315 9,307 8,381Total Energy to Food (Btu) 16,834 16,751 15,693Energy to Food (Btu/lb) 461 459 427Total Equipment Energy Consumption (Btu) 43,787 43,684 40,065Energy to Equipment (Btu/lb) 1,200 1,196 1,090
ResultsCooking Energy Efficiency (%) 38.4 38.3 39.2Gas Cooking Energy Rate (Btu/h) 59,397 59,803 54,244Control Energy Rate (W) 220 222 217Production Capacity (lb/h) 50.1 50.6 50.5Average Recovery Time (sec) 89 83 82
Energy Efficiency Uncertainty ResultsAverage (%) 38.6Standard Deviation (%) 0.5Absolute Uncertainty (%) 1.2% Uncertainty 3.1
Production Capacity Uncertainty ResultsAverage (lb/h) 50.4Standard Deviation 0.3Absolute Uncertainty (lb/h) 0.7% Uncertainty 1.4
Pilot Energy Rate (Btu/h)
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 7 of 12
FSTC Equipment Test Report SG CRT 151028
Additions, Deviations, and Exclusions
Additions:
Deviations:
Exclusions:
None
None
Cooking Tests• Only a heavy-load test was performed for Hamburger cooking tests, rather than light-load and heavy-load tests specified in section 10.7.5.2 of ASTM standard F1275-03
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 8 of 12
FSTC Equipment Test Report
ECP 160104
ENERGY STAR® Qualification FSTC testing of the Vulcan VCCG36-AR01 Gas Griddle resulted in an idle rate of 2,141 Btu/h/ft² and an energy efficiency of 38.6%. The results comply with the ENERGY STAR® program requirement for Commercial Griddles, version
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 9 of 12
FSTC Equipment Test Report
ECP 160104
Manufacturer Specifications Sheet
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 10 of 12
FSTC Equipment Test Report
ECP 160104
Manufacturer Specifications Sheet (Continued)
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 11 of 12
FSTC Report # 501311462-R0 12949 Alcosta Blvd. Suite 101, San Ramon, CA 94583 P: 1.800.398.3782 F: 1.925.866.2864 www.fishnick.com
Page 12 of 12