fortimo led line gen3 - · pdf filefortimo led line systems are designed to produce pure white...
TRANSCRIPT
LED Line 2 ft 2200 lm 1R LV3
May 2016
Datasheet
Key features and benefits• State-of-the-art LED module efficiency of up to 165 lm/W• Long life-time: >50,000 hours• High color rendering (CRI >80 and >90)• Excellent color consistency of 3 SDCM• Choice of color temperatures (3000 K, 4000 K and 5000 K)• Two lumen packages: 650 lm and 1100 lm per foot/280 mm• LED module range with 1, 2 or 3 rows of LEDs• Tunable lumen output, efficacy and lifetime• Push-in connectors enabling automated wiring• Five year system warranty
Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo LED Line portfolio consists of 3 main ranges of products, which have been differentiated by the number of rows of LEDs contained on the module. Fortimo LED Linear encompasses a wide range, offering solutions for all the different types of linear luminaires.
Fortimo LED Line Gen3
Retail O�ce Industry
Suitable for:
2 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Ordering data
Commercial product name EOC 12NC Box quantity
Fortimo LED line 2ft 2200lm 830 1R LV3 8718696 412749 00 9290 009 19906 180
Fortimo LED line 2ft 2200lm 840 1R LV3 8718696 412848 00 9290 009 20106 180
Fortimo LED line 2ft 2200lm 850 1R LV3 8718696 412862 00 9290 009 20206 180
Drive currents and case temperatures
Parameter Nominal* Life** Max*** Unit
I (current through the LED module) 468 600 700 mA
Tc (case temperature at Tc point) 45 80 80 °C
* Nominal value at which typical performance is specified.** Value at which lifetime L70B50 ≥ 50,000 hour is specified.*** Maximum value for safe operation; do not operate above this value.
Optical characteristics - table per color (CCT)
Fortimo LED line 2 ft 2200 lm 830 1R LV3Parameter Min Typ Max Unit
Correlated color temperature (CCT) 3000 K
Color coordinates (CIEx, CIEy)* (0.430,0.398) -
CRI** 80 -
Radiation angle 120 deg
Color consistency of 3 SDCM, averaged over the module. R9 of 3, typical value.
Rel
ativ
e in
tens
ity
(a.u
)
Wavelength (nm)
1
0.8
0.6
0.4
0.2
0380 430 480 530 580 630 680 730 780
830
Operation point 830 lm lm/W
80% I-nom 374 mA Tc 25 °C 1737 152
Tc-nom 45 °C 1691 151
Tc-life 80 °C 1594 146
I-nom 468 mA Tc 25 °C 2148 146
Tc-nom 45°C 2092 145
Tc-life 80 °C 1971 140
I-life 600 mA Tc 25 °C 2712 138
Tc-nom 45 °C 2640 137
Tc-life 80 °C 2488 132
Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.
Fortimo LED line 2 ft 2200 lm 840 1R LV3Parameter Min Typ Max Unit
Correlated color temperature (CCT) 4000 K
Color coordinates (CIEx, CIEy)* (0.381,0.378) -
CRI** 80 -
Radiation angle 120 deg
Color consistency of 3 SDCM, averaged over the module. R9 of 16, typical value.
Rel
ativ
e in
tens
ity
(a.u
)
Wavelength (nm)
1
0.8
0.6
0.4
0.2
0380 430 480 530 580 630 680 730 780
840
Operation point 840 lm lm/W
80% I-nom 374 mA Tc 25 °C 1827 160
Tc-nom 45 °C 1779 158
Tc-life 80 °C 1676 154
I-nom 468 mA Tc 25 °C 2259 154
Tc-nom 45 °C 2200 152
Tc-life 80 °C 2073 147
I-life 600 mA Tc 25 °C 2852 146
Tc-nom 45 °C 2777 144
Tc-life 80 °C 2617 139
Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.
3 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
180°
30°30°
60°60°
90°90°
120°120°
100
200
300
400
(cd/1000 lm 0° L.O.R.= 1.00
0-180° 90-270°
Beam shape
The Philips LED module generates a Lambertian beam shape, which is a pragmatic starting point for OEMs wishing to design secondary optics.
Fortimo LED line 2 ft 2200 lm 850 1R LV3Parameter Min Typ Max Unit
Correlated color temperature (CCT) 5000 K
Color coordinates (CIEx, CIEy)* (0.343,0.351) -
CRI** 80 -
Radiation angle 120 deg
Color consistency of 3 SDCM, averaged over the module. R9 of 11, typical value.
Rel
ativ
e in
tens
ity
(a.u
)
Wavelength (nm)
1
0.8
0.6
0.4
0.2
0380 430 480 530 580 630 680 730 780
850
Operation point 850 lm lm/W
80% I-nom 374 mA Tc 25 °C 1827 160
Tc-nom 45 °C 1779 158
Tc-life 80 °C 1676 154
I-nom 468 mA Tc 25 °C 2259 154
Tc-nom 45 °C 2200 152
Tc-life 80 °C 2073 147
I-life 600 mA Tc 25 °C 2852 146
Tc-nom 45 °C 2777 144
Tc-life 80 °C 2617 139
Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.
Measurement tolerance is ±5% for the flux data and 6% for the efficacy data.* Measurement tolerance is ± 0.005** Measurement tolerance is ± 1.5
Electrical characteristics
Parameter Min Typ Max Unit
Nominal current 468 mA
Forward voltage 29.4 30.9 32.4 V
Power consumption 13.8 14.5 15.2 W
Energy efficiency label A++
Minimum dimming for performance 10 %
Number of parallel modules per chain 2
Bins 2 (C and D)
Specifications stated at Tc-nom and I-nom.
4 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Performance over life
Lumen maintenanceOperation point Time x 1000 hours L70 L80 L90
B50 B20 B10 B50 B20 B10 B50 B20 B10
80% I-nom 374 mA Tc 25 °C >70 >70 >70 >70 >70 >70 36 35 35
Tc-nom 45 °C >70 >70 >70 65 63 61 30 29 29
Tc-life 80 °C 70 70 68 45 43 42 21 21 20
I-nom 468 mA Tc 25 °C >70 >70 >70 >70 70 69 34 33 32
Tc-nom 45 °C >70 >70 >70 61 58 57 29 28 27
Tc-life 80 °C 68 65 64 42 41 40 20 19 19
I-life 600 mA Tc 25 °C >70 >70 >70 66 64 62 31 30 29
Tc-nom 45 °C >70 >70 >70 55 53 52 26 25 25
Tc-life 80 °C 61 59 58 38 37 36 18 17 17
Values in the table are based on available LM80 LED data (12,000h). Lumen maintenance will be updated once additional measurement data becomes available.
Parameter Min Typ Max Unit
Δu'v' at 6000 hours 0.007 -
Specifications stated while Tc < Tc-life and I < I-life.
Absolute maximum ratings
Parameter Min Typ Max Unit
Current through the LED module (I-max) 700 mA
Case temperature (Tc-max) 80 °C
Power rated at U-max and I-max 25.2 W
ESD (direct contact) 8 kV
ESD (air) 15 kV
Working voltage (between input to metal mounting plate) 120 Vdc
Voltage strength (Input to metal mounting plate) 1240 Vac
Ambient temperature -40 °C
Wiring
Specification item Value Unit Condition
Input wire cross-section 0.2…0.75 mm2 Solid
18…24 AWG
0.3..0.5 mm2 Stranded
20..22 AWG
Input wire strip length 7.5..8.5 mm
Tested cable length 4000 mm Total length of wiring including LED modules,
one way
Connector suited for robot wiring.
5 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Mechanical characteristics
Parameter Min Typ Max Unit
Length 560.2 560.7 561.2 mm
Width 39.5 40 40.5 mm
Height excl. connector 2 2.1 2.2 mm
Height incl. connector 5.6 5.8 6 mm
Warpage (IPC-TM-650) 4 %
Bow & Twist of the PCB after production tested and released according IPC-TM-650 2.4.22.
ININ
OUTOUT
Ø 4
.75
1.5
7.75
A (4:1)
A
36.5536.5543.85 43.45
110 30.5
14.3 12.7
42 x 12.7 + 14.3 = 547.7 +/- 0.3
11029.85
16
40 22
101.
65
0.8
3
4.3
4
8
43.45
560.7
60.5
5.9
930
31
7
4
ININ
OUTOUT
Connector, suited for robot wiringPolarity sensitive
Connector, suited for robot wiringPolarity sensitive
Screw hole (6x)max. M4 screw size
Hole allows wire feedthrough
Fuse Fuse
Approbation andconformity marks
Area suited for clamping (10x)
Module speci�cinfo sticker Tc point
6 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Application information
Compliance and approvalIEC / EN 62031, IEC / EN 62471, UL 8750
Photobiological safetyRisk group: Risk group 1
EnvironmentalRoHS / REACH
Application informationZhaga
Designation of the Book-7 LLE category L56W4
Luminous Flux category C020
CCT category 3000 K, 4000 K, 5000 K
CRI 80
The position of the temperature measurement point tp Same as Tc point
The value of tp,max 45
IP rating No IP rating
Overheating protection No protection
Luminaire class IEC Class II
Thermal switching table
Calculated number of switches at which the survival rate of the population ≥90%, at a given ambient temperature and delta T with repect to Tc (where Tc = Tambient + delta T)
Tambient [°C]
-40 -30 -20 -10 0 10 20 30 40 50 60 70
de
lta
T [°
C]
(de
lta
T =
Tc -
Tam
bie
nt)
10
Co
nti
nu
ou
s o
pe
rati
on
or
dim
min
g o
nly
>100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k
20 >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k X
30 >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k >100 k X X
40 45 k 45 k 45 k 45 k 45 k 45 k 45 k 45 k X X X
50 20 k 20 k 20 k 20 k 20 k 20 k 20 k X X X X
60 10 k 10 k 10 k 10 k 10 k 10 k X X X X X
70 5 k 5 k 5 k 5 k 5 k X X X X X X
80 3 k 3 k 3 k 3 k X X X X X X X
90 2 k 2 k 2 k X X X X X X X X
100 1 k 1 k X X X X X X X X X
7 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Flux and efficacy versus currentI [mA] Flux [%] Efficacy [%]
(I-nom x 50%) 230 50% 111%
280 61% 109%
340 74% 106%
400 86% 103%
(I-nom) 468 100% 100%
520 110% 98%
(I-life) 600 126% 95%
Flux and efficacy versus temperature at TcTc [°C] Flux [%] Efficacy [%]
(Tc-life) 80 94% 97%
75 95% 97%
70 96% 98%
(Tc-nom) 45 100% 100%
25 103% 101%
0 106% 102%
Tuning information
0 10 20 30 40 50 60 70 80
Tc (°C)
110%
105%
100%
95%
90%
85%
80%
75%
Valu
e re
lati
ve t
o n
om
inal
(%
)
E�cacy (%)Flux (%)
200 240 280 320 360 400 440 480 520 560 600 640
Single LED module current (mA)
140%130%120%110%
100%90%80%70%60%50%40%30%
Rel
ativ
e nu
mb
er
E�cacy (%)Flux (%)
8 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Lumen maintenance
0% 100%
0% 100%
70%
0 10,000 20,000 30,000 40,000 50,000 70,000 60,000
Operating lifetime (hours)
Lum
en m
aint
enan
ce (
%) Lum
en dep
reciation (%
)
B50B10
0% 100%
0% 100%
70%
0 10,000 20,000 30,000 40,000 50,000 70,000 60,000
Operating lifetime (hours)
Lum
en m
aint
enan
ce (
%) Lum
en dep
reciation (%
)
Tc 25 °CTc nom 45 °CTc-life 80 °C
Lumen maintenance at I-life and Tc-life conditions
Lumen maintenance for B50 at current I-life conditions
Lumen depreciation as a function of operating hours for I-life and Tc-life.
Lumen depreciation as a function of operating hours at different Tc values and I-life.
9 - 10 Datasheet - Fortimo LED Line 2 ft 2200 lm 1R LV3 May 2016
Wiring schematic
More information in the design-in guide of LED Linear modules.
Isolated (SELV) LED driver 2 ft LV LED board
2 ft LV LED board
2 ft LV LED board
2 ft LV LED board
Datasheet 13
+-
Isolated (SELV) LED driver +-
LV system1 chain (1C)
LV system2 chain (2C)
Chain 1 di�erent lenghtas Chain 2 = OK
Idrive = Inom x # boards
Vdrive = Vf
Rset
Rset
Examples
© Philips Lighting Holding B.V. 2016. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.
05/2016 Data subject to change
www.philips.com/technology www.philips.com/fortimo www.philips.com/xitanium