frank hertz experiment - university of rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf ·...
TRANSCRIPT
![Page 1: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/1.jpg)
Frank Hertz ExperimentFrank Hertz Experiment
Ben Richard and Katrina SliwaBen Richard and Katrina SliwaPHY243WPHY243W
![Page 2: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/2.jpg)
Preview of Things to ComePreview of Things to Come
HistoryHistory TheoryTheory ApparatusApparatus IonizationIonization ExcitationExcitation ShieldingShielding ConclusionsConclusions
![Page 3: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/3.jpg)
History History
In 1914, by James Franck and Gustav Ludwig HertzIn 1914, by James Franck and Gustav Ludwig Hertz One year after Bohr’s theory of quantized energy states One year after Bohr’s theory of quantized energy states Nobel Prize in 1925: “for their discovery of the laws Nobel Prize in 1925: “for their discovery of the laws
governing the impact of an electron upon an atom”governing the impact of an electron upon an atom”
Photos: Copyright © The Nobel Foundation
![Page 4: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/4.jpg)
Energy LevelsEnergy Levels
Bohr: discrete energy levelsBohr: discrete energy levels Excite electrons with electron impactExcite electrons with electron impact Hg: 80 electronsHg: 80 electrons Excited transitions from electrons Excited transitions from electrons
33PP0 0 →→ 11SS00 ((4.6 eV)4.6 eV)
33PP1 1 →→ 11SS00 ((4.9 eV)4.9 eV)
33PP2 2 →→ 11SS00 ((5.4 eV)5.4 eV)
11PP1 1 →→ 11SS00 ((6.7 eV)6.7 eV)
![Page 5: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/5.jpg)
Electron ScatteringElectron Scattering
Why Hg?Why Hg? Monoatomic vaporMonoatomic vapor Easy to control vapor pressure Easy to control vapor pressure
Mean free path through a gas in a cavity:Mean free path through a gas in a cavity:I = (2I = (2ππnRnR00))-½ -½
Kinetic energy gained in an electric field during I: Kinetic energy gained in an electric field during I: K = eEIK = eEI
Elastic scattering: K < Elastic scattering: K < ΔΔEnergy between statesEnergy between states Inelastic scattering: K = Inelastic scattering: K = ΔΔEnergy between statesEnergy between states
![Page 6: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/6.jpg)
Frank Hertz Vacuum TubeFrank Hertz Vacuum Tube
Anode
Cathode (VF)
Grid (VCG)
Electric field
![Page 7: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/7.jpg)
Frank HertzBox
Control Box
Multimeter Electrometer
To Computer
A
G
F C
Experimental Setup Experimental Setup Thermometer
B
![Page 8: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/8.jpg)
IonizationIonization
Anode at negative potential w.r.t. cathodeAnode at negative potential w.r.t. cathode Grid at positive potential w.r.t. cathodeGrid at positive potential w.r.t. cathode Electrons can ionize mercuryElectrons can ionize mercury
positive Hg ions pulled toward anodepositive Hg ions pulled toward anode SettingsSettings
Retarding voltage: 1.5 VRetarding voltage: 1.5 V VVf f = 6.3 V= 6.3 V Temperature from 100Temperature from 10000C to 185C to 18500CC
![Page 9: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/9.jpg)
Temperature ResultsTemperature Results
![Page 10: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/10.jpg)
Ionization ResultsIonization Results
![Page 11: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/11.jpg)
DiscussionDiscussion
1.5 V retarding potential 1.5 V retarding potential 0 V < V0 V < Vcg cg < 15 V at 0.1 V steps < 15 V at 0.1 V steps Inconclusive resultsInconclusive results Expected value: 10.39 eVExpected value: 10.39 eV Potential sources of errorPotential sources of error
Recommended retarding voltage too lowRecommended retarding voltage too low Filament voltage possibly incorrect Filament voltage possibly incorrect
![Page 12: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/12.jpg)
ExcitationExcitation Retarding voltage: 1.5 VRetarding voltage: 1.5 V VVf f = 6.30 V= 6.30 V
0 V < V0 V < Vcgcg < 45 V in 0.1 V steps < 45 V in 0.1 V steps Assumptions: Assumptions:
KKe cathodee cathode= 0 = 0 All electrons with KAll electrons with Kee < eV < eVretardingretarding captured by grid captured by grid Electrons with required energy travel negligible Electrons with required energy travel negligible
distances before collisiondistances before collision
![Page 13: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/13.jpg)
Excitation resultsExcitation results
![Page 14: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/14.jpg)
Excitation resultsExcitation results
Avg dist between peaks: 4.93Avg dist between peaks: 4.93+/- .25 eV+/- .25 eV For Hg: For Hg: ΔΔE = 4.6 eV, 4.9 eV, 5.4 eV, 6.7 eVE = 4.6 eV, 4.9 eV, 5.4 eV, 6.7 eV Lifetime Lifetime 33PP0 0 →→
11SS0 0 >> Lifetime >> Lifetime 33PP1 1 →→ 11SS00
Accepted value: 4.9 eVAccepted value: 4.9 eV h = Veh = Veλλ/c; /c; λλ = 253.6 x 10 = 253.6 x 10-9-9 m m h = 6.63 +/- .34 x 10h = 6.63 +/- .34 x 10-34 -34 Js Js Accepted value: h=Accepted value: h= 6.626 x 106.626 x 10-34-34 Js Js
![Page 15: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/15.jpg)
Excitation ObservationsExcitation Observations
![Page 16: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/16.jpg)
Excitation ObservationsExcitation Observations
www.physics.umd.edu/.../demos/demosn2/n2-06.htm
![Page 17: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/17.jpg)
Electrometer Electrometer
Very sensitive to external electric fieldsVery sensitive to external electric fields Attempted to create grounded tin foil shield Attempted to create grounded tin foil shield
![Page 18: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/18.jpg)
ConclusionsConclusions
Inconclusive ionization results Inconclusive ionization results Found excitation peaks at: 4.93Found excitation peaks at: 4.93+/- .25 eV+/- .25 eV Measured h to be: 6.63 +/- .34 x 10Measured h to be: 6.63 +/- .34 x 10-34 -34 Js Js Future work:Future work:
Fine tune parameters for ionization Fine tune parameters for ionization Obtain VObtain Vff experimentally experimentally Create better shield for electrometerCreate better shield for electrometer
![Page 19: Frank Hertz Experiment - University of Rochesteradvlab/reports/sliwa_richard_franck_hertz.pdf · Frank Hertz Box Control Box Multimeter Electrometer ... The Franck-Hertz Experiment](https://reader036.vdocuments.net/reader036/viewer/2022081800/5b77ba5b7f8b9aee298d96cf/html5/thumbnails/19.jpg)
References References UR Advanced Laboratory Manual, The Franck-Hertz
Experiment [Online] http://www.pas.rochester.edu/~AdvLab/2-Frank-Hertz/Lab02%20Hertz.pdf
K. M. Beck and J. Mainzer, The Franck-Hertz Experiment [Online] http://www.pas.rochester.edu/~advlab/reports/beck_mainzer_franckhertz.pdf
A. C. Melissinos, Experiments in Modern Physics Academic Press (1966)
C. J. Sansonetti C. J. Sansonetti et al.et al., Phys. Scr. , Phys. Scr. 6363 219-242, 2001 219-242, 2001 Nobel Foundation Nobel Foundation
http://nobelprize.org/nobel_prizes/physics/laureahttp://nobelprize.org/nobel_prizes/physics/laureates/1925/index.htmltes/1925/index.html