Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA 02466 617-332-7004 • 617-332-4137 (fax) • Internet: www.fvfowler.com Inside Jaws Clamp Screw Outside Jaws Vernier Scale Guiding Surface Beam Depth Rod Slider Fine Adjust DIRECTIONS 1. Clean the measuring and guiding surfaces before using. 2. Move the slider forward to make the measuring surfaces contact with each other then check the alignment of zero lines of main scale and vernier. 3. While measuring, the measuring force should not be too strong, otherwise the measuring accuracy will be influenced. 4. When reading, your sight line should be perpendicular to the graduation surface. 5. To prolong the life of your caliper, it should be cleaned and oiled to prevent corrosion and stored in the fitted case. Detail of a vernier scale. This vernier reads to 0.001" 1" + .4" + .025 = 1.425 + .013 = 1.438" Example: In the above illustration, the vernier has been moved to the right 1.000 plus 0.400 plus 0.025 which is equal to 1.425 inches. This is indicated by the "0" line on the bottom vernier. The thirteenth line on the vernier coincides with a line on the scale as indicated by the circles. Therefore 0.013" is added to the reading on the scale, giving a total reading of 1.438" VERNIER CALIPERS Part Number: 52-058-016 Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA 02466 617-332-7004 • 617-332-4137 (fax) • Internet: www.fvfowler.com Inside Jaws Clamp Screw Outside Jaws Vernier Scale Guiding Surface Beam Depth Rod Slider Fine Adjust DIRECTIONS 1. Clean the measuring and guiding surfaces before using. 2. Move the slider forward to make the measuring surfaces contact with each other then check the alignment of zero lines of main scale and vernier. 3. While measuring, the measuring force should not be too strong, otherwise the measuring accuracy will be influenced. 4. When reading, your sight line should be perpendicular to the graduation surface. 5. To prolong the life of your caliper, it should be cleaned and oiled to prevent corrosion and stored in the fitted case. Detail of a vernier scale. This vernier reads to 0.001" 1" + .4" + .025 = 1.425 + .013 = 1.438" Example: In the above illustration, the vernier has been moved to the right 1.000 plus 0.400 plus 0.025 which is equal to 1.425 inches. This is indicated by the "0" line on the bottom vernier. The thirteenth line on the vernier coincides with a line on the scale as indicated by the circles. Therefore 0.013" is added to the reading on the scale, giving a total reading of 1.438" VERNIER CALIPERS Part Number: 52-058-016

Upload: others

Post on 17-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA ... · Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA 02466 617-332-7004 • 617-332-4137 (fax) • Internet:

Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA 02466 617-332-7004 • 617-332-4137 (fax) • Internet: www.fvfowler.com

Inside JawsClamp Screw

Outside Jaws

Vernier Scale Guiding Surface

Beam Depth Rod

SliderFine Adjust

DIRECTIONS1. Clean the measuring and guiding surfaces before using.2. Move the slider forward to make the measuring surfaces contact with each other then check the

alignment of zero lines of main scale and vernier.3. While measuring, the measuring force should not be too strong, otherwise the measuring accuracy

will be influenced.4. When reading, your sight line should be perpendicular to the graduation surface.5. To prolong the life of your caliper, it should be cleaned and oiled to prevent corrosion and stored in

the fitted case.

Detail of a vernier scale. This vernier reads to 0.001"

1" + .4" + .025 = 1.425 + .013 = 1.438"

Example:In the above illustration, the vernier has been moved to the right 1.000 plus 0.400 plus 0.025 which is equal to 1.425 inches. This is indicated by the "0" line on the bottom vernier. The thirteenth line on the vernier coincides with a line on the scale as indicated by the circles. Therefore 0.013" is added to the reading on the scale, giving a total reading of 1.438"

VERNIER CALIPERSPart Number: 52-058-016

Fred V. Fowler Co., Inc. • 66 Rowe Street • Newton, MA 02466 617-332-7004 • 617-332-4137 (fax) • Internet: www.fvfowler.com

Inside JawsClamp Screw

Outside Jaws

Vernier Scale Guiding Surface

Beam Depth Rod

SliderFine Adjust

DIRECTIONS1. Clean the measuring and guiding surfaces before using.2. Move the slider forward to make the measuring surfaces contact with each other then check the

alignment of zero lines of main scale and vernier.3. While measuring, the measuring force should not be too strong, otherwise the measuring accuracy

will be influenced.4. When reading, your sight line should be perpendicular to the graduation surface.5. To prolong the life of your caliper, it should be cleaned and oiled to prevent corrosion and stored in

the fitted case.

Detail of a vernier scale. This vernier reads to 0.001"

1" + .4" + .025 = 1.425 + .013 = 1.438"

Example:In the above illustration, the vernier has been moved to the right 1.000 plus 0.400 plus 0.025 which is equal to 1.425 inches. This is indicated by the "0" line on the bottom vernier. The thirteenth line on the vernier coincides with a line on the scale as indicated by the circles. Therefore 0.013" is added to the reading on the scale, giving a total reading of 1.438"

VERNIER CALIPERSPart Number: 52-058-016