Fume Hoods
Selection GuideFume Hoods
Description Filter Work Surface Page
Clean BenchesBC-01E
HEPA Filter Stainless Steel #304 26BC-11EBC-21E
Ductless Fume HoodsDLH-01G Optional 6
Different FiltersOptional 6 DifferentWork Surface 30
DLH-11G
PCR WorkstationsPW-01
HEPA Filter Acryl 10 mm / 0.39 inch(Clear type) 34PW-11
PW-21
UV Sterilization CabinetsUVC-01
- Stainless Steel #304 34UVC-11UVC-21
Accessories & OptionsDescription Page
for Clean Benches 29for Ductless Fume Hoods 33for PCR Workstations & UV Sterilization Cabinets 37
![Page 2: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/2.jpg)
General ApplicationsGeneral Applications
Fume Hoods BC-Series PW-Series DLH-Series
Asbestos Handling • •Chemical sampling •Chemical preparationin an electron microscopy or histology laboratory,forensic, and pharmaceutical applications, depending on the solvents used
•
Cosmetic production to photochemical •Dental laboratory •Electronics Inspection / Repair • •Fingerprinting •General Forensics • • •Medical device assembly •Non-biohazardous [Tissue] Culture Maintenance • •
Non-toxic IV Solution Preparation • •Numerous vapor-generating laboratory processes (HPLC preparation and biochemistry protocols can be performed with improved safety and comfort)
•
PCR •Plant Tissue Culture Maintenance • •Powder extraction •QA / QC Testing • • •Slide preparation •Staining with Volatile •Sterile Media Preparation •Syringe filling •Sterile Media Preparation •Tissue Fixation / Staining Preparation • •Touch up painting •Volatile Radiolabeling / Tagging • •Weighing Toxic Powders • •Welding fumes •
* For general purpose use and storage applications.
Technical BenefitsClean benches Ductless fume hoodsSafety functions - 2 separated over- current fuses for user safety. - Toggle switch provided can be selective one of
them. (UV, off, and fluorescent)
- Automated UV lamp switch off when unintended window opening.
- Tempered glass sliding sash window and intercept the UV light for user safety.
- Permanent magnehelic differential pressure gauge displays across the HEPA filter to check the air changes. (optional)
- Using a 99.99% efficient supply HEPA filter.
Ideal construction - Optimum PWM (pulse width modulation) control
performance. - As a blower of large enough capacity is adapted,
sufficient intake flow rate is maintained and noise is reduced.
- Dirt-repellent surface external powder coating.- Light and blower switches are within easy reach
of the user.- Great chemical resistance work surface (#304) with
various organic solvents.
Ideal construction - Front windows part can be seeing through made
by transparent acryl.- Lower Stand mounted fixable casters easy for
moving & fixing. (Optional)- Control Panel : Consist of fluorescent lamp, Fan
Start/Stop, Blower speed controller, alarm, menu and etc.
- Over - current circuit CP (Circuit Protector) for user safety. - Anemometer: Visual for the input air velocity at real
time.- Door Stay : Fixture to fix it when door open at 2 step.
(if it's dropped without backing up, result in damage, and Fixing magnetic enable to open hold it to 1 step-door.)
PCR workstations & UV Sterilization CabinetsIdeal construction - Built-in over-current products for user safety.- Intelligent Digital controller.
(timer, alarm, blower speed (PW-series)) - Pre-filter mounted extends the life of the filters.
(PW-series)- High quality 99.99% efficient supply HEPA filter.- Powerful, uniformly distributed, UV-C.
(average 8,000 hours) - Excellent chemical resistance work surface.
(UVC-series)- Automated UV lamp switch off.
![Page 3: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/3.jpg)
26
Clean Benches
※ Product design subject to change without notice.
BC-11EOptional Accessories •Standwithcaster.
see page 29 •Differentialpressuregauge.
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
Fume Hoods
![Page 4: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/4.jpg)
27
Vertical type laminar flow clean bench!ISO 14644-1 Class 4 air. (formerly Class 10 per Federal Standard 209E)Supply HEPA filter, high efficient for particles beginning at size 0.3micron. Nominal downflow velocity of 0.3m/s. (60fpm)Ergonomic 5 degree sloped front for comfort.
Control panel
Service Fixtures (Optional)
Gas
Vacuum
Air
Filtration features Particle-free ISO 14644-1 Class 4 air
• Particle count in the work area conform to ISO Class 4 conditions (formerly Class 10 per Federal Standard 209E). Supply HEPA filter, 99.99% efficient on particles 0.3 micron.
• Polyester fiber pre-filter that has a minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increase the life of the main filter.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit. ※The HEPA filters life span depending on the test room conditions has a life span about 3 years.
Constructional features Ergonomic design
• Angled front profile is free of protrusions that will not interfere with visibility or obstruct tall users.
• 304 grade stainless steel work surface - Highly durable and rust free work zone, made for easy cleaning.
• Use of tempered glass door to be strong of damage and intercepts the UV light for user safety.
• The door smoothly slides up and down and stops at any height useful for protecting the user when used at a proper level or for easy transportation of experimental apparatuses and equipments into the workspace.
• Right and left both sides also have wide glasses windows for a clear viewing.
• Adjustable blower located by the front blower switch.
Lighting • Electronically ballasted FL lamp is installed on the top center roof inside the hood that
minimizes airflow disturbance and shadows in the work zone, and to relieves eye strain.
• Toggle switch provided can be set up to turn On/Off UV, off, and fluorescent functions, so one can make sure that the user is safely protected from careless switching on UV & fluorescent lamps at the same time.
Clean Bench Airflow Profile • Room air is taken in from the top blower of the bench through a disposable pre-filter.
• The filtered air is first purified by the secondary HEPA filter to confirm to class standards.
• The laminar down-flowing air is supplies from the dual filtering system into the working zone.
• The clean bench work zone easily maintains a high sterile condition due to positive pressure preventing outside contaminants.
• The purified air flows across the work zone in the cabinet in a vertical, unidirectional stream and leaves the main work chamber across the entire open front of the cabinet and in through the slots.
Clean Benches Fume Hoods
![Page 5: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/5.jpg)
28
Dimensions (Model: BC-11E)
Clean Benches Fume Hoods
1. Pre-Filter 2. Blower 3. HEPA Filter 4. UV Lamp 5. Fluorescent Lamps 6. Tempered Glass Side Panel 7. Service Fixture 8. Sliding Front Sash Window 9. Electrical Outlet socket 10. Stainless Steel Grade 304 Work Surface11. Blower Speed Controller 12. Differential pressure gauge
Air flow Diagram
9
10
11
1
2
34
5
8
6
7
12
Specifications & Ordering Informations
Model BC-01E BC-11E BC-21EAir Flow Type Vertical flowAir Volume (Minimum / Maximum) 274 to 914 cmh / 119 to 399 cfmLaminar Airflow Velocity (m / s / fpm) 0.3 / 60Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10
FiltersHEPA Filter Typical efficiency of 99.99% at 0.3㎛ US MIL - STD -282
; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
Pre-Filter Polyester fibers with an efficiency of 85% (A·F·I TEST) ; AL frame, Polyester fiber MediaNoise Level Typically < 67dBA at initial Blower speed
MaterialsMain Body Stainless steel grade 304 & Steel powder coatingWork Surface Stainless steel grade 304Windows (Front / Side) Colorless and transparent UV absorbing 5mm tempered glass
IlluminationIntensity (lux) >1000FL lamp (W) 30W×2EA electronically ballasted FL LampUV lamp (W) 30W electronically ballasted UV Lamp
Electric Socket Outlets 230V socket, 120V socket
Dimensions (W×D×H)
Internal (mm / inch) 970×540×570 / 38.2×21.3×23.2 1270×540×570 / 50×21.3×23.2 1870×540×570 / 73.6×21.3×23.2External Without Stand (mm / inch) 1040×630×1060 / 40.1×24.8×42.7 1340×630×1060 / 52.8×24.8×42.7 1940×630×1060 / 76.4×24.8×42.7External With Stand (mm / inch) 1040×630×1780 / 40.1×24.8×70.1 1340×630×1780 / 52.8×24.8×70.1 1940×630×1780 / 76.4×24.8×70.1Weight (Body) (kg / lbs) 110 / 242.5 110 / 242.5 110 / 242.5Weight (Body+Stand) (kg / lbs) 130 / 302 150 / 330.7 190 / 418.9
Electrical Requirements (230V) 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82A 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82A 60Hz / 1ph / 1.7A 50Hz / 1ph / 1.82ACat. No. AAHA4011K AAHA4012K AAHA4021K AAHA4022K AAHA4031K AAHA4032KElectrical Requirements (120V) 60Hz / 1ph / 3.48A 60Hz / 1ph / 3.48A 60Hz / 1ph / 3.48A Cat. No. AAHA4013U AAHA4023U AAHA4033U
![Page 6: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/6.jpg)
29
for Clean Bench
Accessories & Options for Clean Benches
HEPA Filter (1EA included)
- 99.99% efficient HEPA filter, industry standard size for economical replacement.
Electric Sockets (optional)
- Provided included a conveniently placed power source for small devices or equipment used within the cabinet. Two style of outlets are avail-able; 120V and 230V outlets.
Pre-Filter (1EA included)
- Replaceable pre-filter, to trap larger particles, extends HEPA filter life.
Differential Pressure Gauge (optional)
- Permanent magnhelic pressure differential gauge display across the HEPA filter to check the air changes.
UV Lamp (optional)
- For secondary method of decontamination while the bench is not in use.
Fume Hoods
Basic Stand (optional)
- Economical basic stand without casters made of powder coated steel.
Stand with Casters (optional)
- For easy transport with casters made of powder coated steel.
Service Fixture (optional)
- Conveniently hook up source a Gas/ Vacuum/ Air source within the working area.
- CSA limited (Canadian Standards Association)
Accessories for BC-01 / 11 / 21E
Cat. No. DescriptionAAAB1501 BCE-501 HEPA Filter for BC-01EAAAB1502 BCE-502 HEPA Filter for BC-11EAAAB1503 BCE-503 HEPA Filter for BC-21EAAAB1511 BCE-511 Pre Filter for BC-01EAAAB1512 BCE-512 Pre Filter for BC-11EAAAB1513 BCE-513 Pre Filter for BC-21EAAAB1521 BCE-521 Basic Stand for BC-01EAAAB1522 BCE-522 Basic Stand for BC-11EAAAB1523 BCE-523 Basic Stand for BC-21EAAAB1531 BCE-531 Stand with casters for BC-01E
※ In addition to providing standard accessories, we will manufacture customized accessories to meet your specific needs. Please contact Jeio Tech for details.
Cat. No. DescriptionAAAB1532 BCE-532 Stand with casters for BC-11EAAAB1533 BCE-533 Stand with casters for BC-21EAAAB1541 BCE-541 UV lamp for BC-01E (230V)AAAB1542 BCE-542 UV lamp for BC-01E (120V)AAAB1543 BCE-543 UV lamp for BC-11E (230V)AAAB1544 BCE-544 UV lamp for BC-11E (120V)AAAB1545 BCE-545 UV lamp for BC-21E (230V)AAAB1546 BCE-546 UV lamp for BC-21E (120V)AAAB1551 BCE-551 Electrical socket for BC-01/11/21EAAAB1561 BCE-561 Gas cock for BC-01/11/21EAAAB1571 BCE-571 Differential pressure gauge for BC-01/11/21E
![Page 7: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/7.jpg)
30
Ductless Fume Hoods
DLH-01G Optional Accessories •Standwithcaster. •Differenttypesofchemicalfilters. see page 33 •6Differenttypesofworksurfaces.
Fume Hoods
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
![Page 8: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/8.jpg)
31
Ductless Fume Hoods
Ductless Fume Hoods are manufactured and gonethrough a complete safety tests of rigorouslyinternational standards.
Constructional features • Internal airflow speed in the workspace can be identified with
attached anemometer. Airflow speed can be controlled by identifying varying wind speeds in accordance with the surroun-ding environments and filter conditions.
• Connection with a separate exhaust system is not required, since the hood uses reticulating air flow by discharging the filtered air into the laboratory.
• Other types of filter cartridges can be easily replaced by opening the upper cover located in the front.
• Front sash can be fully opened or fixed for easy transportation of experimental apparatuses and equipments into the workspace.
• A utility hole is manufactured in the fume hood, for use of appa-ratuses inside the hood allows for easy connection of power source or other cable outport sources outside the hood.
• A blower of large enough capacity is adopted into the equipment so sufficient intake air flow rate is maintained to reduce noise.
• A fluorescent light is provided outside the workspace so that the air flow is not hindered, prevents contamination of reagents and the illumination intensity is maintained.
• Various filters and work surfaces are available to fit your experimental needs. (Refer to accessory section)
Reliable Test : Efficiency, Capacity of Activated carbon filters tested according to
BS 7989:2001 : Structure, Electrical outlet, Lighting, Sound level tested according to
BS 7258-1:1994 : Local smoke, Large volume visualization, Face velocity, Tracer gas
tested according to ANSI / ASHRAE 110-1995, NF EN 14175-1
Selection for Chemical Filter
Code Filter Name ApplicationGF Activated carbon Filter All common laboratory chemicals, especially VOC, Organic, Benzene, Toluene, etcAC Acid Filter An acidic solvent; Acetic acid, Hydrochloric acid, etcHF Halogen Compound Filter Halogen compounds like Chlorine, Flourine, Iodine, Bromine, Astatine, etcFF Formaldehyde Filter Formadehyde applicationsAM Ammonia / Amine Filter Ammonia / Amines by chemisorptions
HEPA HEPA Filter The filtration efficiency of 99.99% at 0.3 microns For trapping biohazardous aerosols and other visible and non visible particles
Digital controller
Utility hole
Anemometer
Front cover
Fume Hoods
![Page 9: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/9.jpg)
32
Ductless Fume Hoods
1. Exhaust Hole 2. Pre-filter 3. Front cover 4. Blower 5. Control Panel 6. Chemical filter 7. F.L. Lamp (INNER) 8. Anemometer 9. Front Door 10. Side viewing Panel 11. Door Opening Fixed Magnet 12. Utility Hole
Dimensions (Model: DLH-01G)
Fume Hoods
9
10
11
1
2
3 4
5
8
6
7
12
Air flow Diagram
Specifications & Ordering Informations
Model DLH-01G DLH-11GFume Hood Type Ductless
Permissibleenvironmental condition
Temperature 5℃ to 40℃Maximum relative humidity 80%
Altitude up to 2,000m
Controller Microprocessor controlFace Velocity Initial set point : 0.4m/s, 80fpmAir flow meter Swing Vane TypeMain Filter Chemical Filter (Optional 6 Different filters)
Pre-filter Washable High efficiency nylon filter
MaterialsMain body 2.0mm steel (Epoxy powder-coated)
Work surface Optional 6 Different work surfacesWindow (Front / Side) Acryl 8mm / Acryl 6mm
Fluorescent Light Intensity > 600lux Sound Emission 55dB at Normal Operation
Dimensions(W×D×H)
Internal (mm / inch) 880×640×800 / 34.6×25.2×31.5 1180×640×800 / 46.5×25.2×31.5External Without Stand (mm / inch) 900×660×1248 / 35.4×26×49.1 1200×660×1248 / 47.2×26×49.1External With Stand (mm / inch) 900×660×1953 / 35.4×26×76.8 1200×660×1953 / 47.2×26×76.8Weight (Body) (kg / lbs) 100 / 220.5 118 / 260.1Weight (Body+Stand) (kg / lbs) 120 / 264.6 140 / 308.6
Electric requirement AC 230V, 60Hz / 0.7ACat. No. AAAB2001 AAAB2011Electric requirement AC 230V, 50Hz / 0.6ACat. No. AAHB2002K AAHB2012KElectric requirement AC 120V, 60Hz / 1.3ACat. No. AAHB2003U AAHB2013UElectric requirement AC 100V, 50Hz / 1.5ACat. No. AAHB2004U AAHB2014U
![Page 10: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/10.jpg)
33
Accessories & Options for Ductless Fume Hoods
Gas Detector and Tubes Filters
Work Surfase Stand with Caster
for Ductless Fume Hoods
Fume Hoods
Accessories for DLH-01G / 11G
Cat. No. DescriptionAAAB2521 Stand with casters for DLH-01G
AAAB2522 Stand with casters for DLH-11G
EDA9191 GF Activated carbon filter for DLH-01G
EDA9192 GF Activated carbon filter for DLH-11G
EDA9199 AC Acid filter for DLH-01G
EDA9200 AC Acid filter for DLH-11G
EDA9201 HF Halogen compounds filter for DLH-01G
EDA9202 HF Halogen compounds filter for DLH-11G
EDA9203 FF Formaldehyde filter for DLH-01G
EDA9204 FF Formaldehyde filter for DLH-11G
EDA9205 AM Ammonia / Amines filter for DLH-01G
EDA9206 AM Ammonia / Amines filter for DLH-11G
EDA9193 HEPA filter for DLH-01G
EDA9194 HEPA filter for DLH-11G
EDA9196 Prefilter for DLH-01G
EDA9198 Prefilter for DLH-11G
AAAB1531 BCE-531 Stand with casters for BC-01E
※ Above spec can be changed without prior notice.
Cat. No. DescriptionAAAB2501 Work surface (SUS #304) for DLH-01GAAAB2502 Work surface (SUS #304) for DLH-11GAAAB2503 Work surface (SUS #316L) for DLH-01GAAAB2504 Work surface (SUS #316L) for DLH-11GAAAB2505 Work surface (Ceramite) for DLH-01GAAAB2506 Work surface (Ceramite) for DLH-11GAAAB2507 Work surface (Polypropylene) for DLH-01GAAAB2508 Work surface (Polypropylene) for DLH-11GAAAB2509 Work surface (Bakelite) for DLH-01GAAAB2510 Work surface (Bakelite) for DLH-11GAAAB2511 Work surface (PVC) for DLH-01GAAAB2512 Work surface (PVC) for DLH-11GAAAB2531 Gas Detector (KITAGAWA AP-20)
EAA1550 Gas Detecting tube (Benzene, GASTEC-121SP (0.5-10ppm))
EDA9207 Gas Detecting tube (Toluene, GASTEC-122L (1-100ppm))
EAA1552 Gas Detecting tube (Acetic acid, GASTEC-81L (0.125-25ppm))
EAA1553 Gas Detecting tube (Chloroform, GASTEC-137 (4-400ppm))
EAA1554 Gas Detecting tube (Formaldehyde, GASTEC-91LL (0.05-1ppm))
EAA1555 Gas Detecting tube (Ammonia, GASTEC-3L (0.5-60ppm))
![Page 11: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/11.jpg)
34
PCR Workstations & UV Sterilization cabinetsFume Hoods
Please visit .comFor further information on Jeio Tech´s Fume Hood products Information is readily available on our website.
PCR Workstation Included Accessories •HEPAFilter
See page 37 •Pre-Filter •UVLamp •FluorescentLamp
UV Sterilization cabinet Included Accessories •UVLamp
See page 37 •FluorescentLamp
![Page 12: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/12.jpg)
35
PCR Workstations & UV Sterilization cabinetsFume Hoods
Using a HEPA filter provides an effective particulate-free working space for ambient environment conditions. – PW series
High quality UV lamp with a timer control feature is great for sterilizing the workspace before carrying out sensitive or PCR experiments. - UVC series
Constructional features
Effective sterilization 254nm ultraviolet lamp and Fluorescent lamp.
• Adjustable UV-timer for precise control of decontamination. - The variable digital timer for UV exposure with detail settings by
second. (Delay OFF: Max. 30min) - Long life (Up to 8,000 hour) UV lamp.
• Anti-glare fluorescent lamp is installed on the center ceiling of the work space area, minimizing shadows and relieves eye strain.
User-Friendly Control System • Microprocessor-based control system. • Bright and vivid LCD (PW - series) or VFD (UVC - series) display with
responsive touch buttons. • Easily indicating the total use time and operating time on the
screen.
A reliable interlock safety system • An audible alarm for product and sample protection against UV
over exposure. • For safety UV-opaque and resistant 99.99%, thick acryl front, back
and sides. • Automatic UV lamp safety shut OFF, in case the door is opened,
which prevents accidental UV exposure. • 304 grade stainless steel work surface - Highly durable and rust
free work zone, made for easy cleaning. (UVC-series)
• Self-protection against over-current.
Additional features
Filtration features (PW-series)
• Particle-free ISO 14644-1 HEPA filter (Class 4 conditions) - Using a 99.99% efficiency HEPA filter that filters particle sizes
of 0.3 micron and greater, traps biohazardous aerosols, and provides a particulate-free work environments that minimizes cross contamination.
• Neoprene gaskets ensures that the HEPA filter is airtight to the body unit.
- The HEPA filters life span depending on the test room conditions has a life span of 3 years.
• Replacing of the HEPA filter can easily be replaced by opening the upper cover, located in the front.
• Polyester fiber pre-filter that has minimal pressure loss and 85% arrestance on the A.F.L. test which serves to trap larger particles and increases the life of the main filter.
• Adjustable digital blower speed switch located in the front with use of large capacity blower is adopted into the equipment.
PCR Workstations
Digital controller
Air flow
UV Sterilization cabinet
Digital controller
![Page 13: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/13.jpg)
36
PCR Workstations & UV Sterilization cabinetsFume Hoods
Specifications & Ordering Informations
PCR Workstations
Model PW-01 PW-11 PW-21
Air Flow type Vertical
Max. air volume (cmh / cfm) 557 / 327 697 / 408 929 / 546
Min. air volume (cmh / cfm) 167 / 97 209 / 121 279 / 162
Laminar airflow velocity (m / s / fpm) 0.3 / 60
Filter
Air cleanliness ISO 14644-1Class 4
HEPA Filter Typical efficiency of 99.99% at 0.3 ㎛ US MIL -STD -282 ; Micro glass fiber Media, Particle board, AL separator, Neoprene gaskets
Pre-Filter Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber Media
Noise level (dBA) Typically < 60 dBA at initial Blower speed
MaterialWork Surface Acryl 10mm (Clear type)
Window (Front, Side / Back) Acryl 8mm / 10mm (Clear type)
Illumination
IntensityFL lamp (lux) >1000
UV Density (㎼/cm2) 165 185 330
CapacityFL Lamp 15W×1EA 20W×1EA 30W×1EA
UV Lamp 15W×1EA 20W×1EA 30W×1EA
Dimensions (W×D×H)
Interior (mm / inch) 700×585×602 / 27.5×23×23.7 880×585×602 / 34.6×23×23.7 1180×585×602 / 46.5×23×23.7
Exterior (mm / inch) 720×605×964 / 28×24×38 900×605×964 / 35.4×24×38 1200×605×964 / 47.2×24×38
Weight (Body) (kg / lbs) 56.2 / 123.9 64.2 / 141.5 77.8 / 171.5
Electric requirement (230V) 60Hz, 1.3A 50Hz, 1.3A 60Hz, 1.4A 50Hz, 1.4A 60Hz, 1.5A 50Hz, 1.5A
Cat. No. AAHB3001 AAHB3002 AAHB3011 AAHB3012 AAHB3021 AAHB3022
Electric requirement (120V) 60Hz, 2.2A 60Hz, 2.7A 60Hz, 2.9A
Cat. No. AAHB3003 AAHB3013 AAHB3023
Specifications & Ordering Informations
UV Sterilization cabinet
Model UVC-01 UVC-11 UVC-21
Illumination
IntensityFl lamp (Lux) >800 >900 >1000
UV Density (㎼ / ㎠) 150 385 450
CapacityFl lamp 8W×1ea 15W×1ea 20W×1ea
UV lamp 8W×1ea 15W×1ea 20W×1ea
MaterialWork Surface Stainless steel grade 304
Window (Front, Back / Side) Acryl 5 mm (Clear type)
Dimensions (W×D×H)
Interior (mm / inch) 433×500×468 / 17.0×19.7×18.4 583×500×468 / 23.0×19.7×18.4 880×500×468 / 34.6×19.7×18.4
Exterior (mm / inch) 450×509×610 / 17.7×20.0×24.0 600×509×610 / 23.6×20.0×24.0 900×509×610 / 35.4×20.0×24.0
Weight (Body) (kg / lbs) 15.0 / 33.1 17.5 / 38.6 20.0 / 44.1
Electric requirement (230V) 60Hz, 0.1A 50Hz, 0.1A 60Hz, 0.2A 50Hz, 0.2A 60Hz, 0.3A 50Hz, 0.3A
Cat. No. AAHB4001 AAHB4002 AAHB4011 AAHB4012 AAHB4021 AAHB4022
Electric requirement (120V) 60Hz, 0.2A 60Hz, 0.4A 60Hz, 0.6A
Cat. No. AAHB4003 AAHB4013 AAHB4023
※ Above spec can be changed without prior notice.
![Page 14: Fume Hoodskromat.hu/UserFiles/files/labormuszer/Jeiotech Fülkék.pdf · 2016-03-01 · Air Cleanliness Within Working Area ISO 14644-1 Class 4, US Federal Standard 209E Class 10](https://reader033.vdocuments.net/reader033/viewer/2022042314/5f01f5c37e708231d401e1e6/html5/thumbnails/14.jpg)
37
Accessories & Options for PW / UVC seriesFume Hoods
General UV dose and time required
PathogenAverage UV dose
required (㎼ . s/㎠)
Average UV time required (㎼/ ㎠ /sec.)
PW-01 UVC-01 PW-11 UVC-11 PW-21 UVC-21165 150 185 385 330 450
S. enteritidis 4,000 25 27 22 10 13 9
B. megatherium sp. (spores) 2,730 17 18 15 7 9 6
B. subtilis 7,100 43 47 39 18 22 16
Eberthella typhosa 2,140 13 14 12 6 7 5
Escherichia coli (E. coli) 3,000 19 20 17 8 10 7
Micrococcus candidus 6,050 37 40 33 16 19 13
Proteus vulgaris 2,640 16 18 15 7 8 6
Pseudomonas aeruginosa 5,500 34 37 30 14 17 12
Pseudomonas aeruginosa 3,500 22 23 19 9 11 8
S. typhimurium 8,000 49 53 44 21 25 18
Shigella paradysenteriae 1,680 101 11 10 4 6 4
Spirillum rubrum 4,400 27 29 24 11 14 10
Staphylococcus albus 1,840 12 12 10 5 6 4
* Environment Condition : temperature 20~25℃, Relative humidity 60%* General purpose use and average disinfection applications
Accessories for PW - 01/11/21
Cat. No. Description
EDA9219 HEPA filter for PW-01
EDA9220 HEPA filter for PW-11
EDA9221 HEPA filter for PW-21
CHE4436 Lighting Lamp for PW-01
CHE4410 Lighting Lamp for PW-11
CHE4409 Lighting Lamp for PW-21
CHE4431 UV Lamp for PW-01
CHE4427 UV Lamp for PW-11
CHE4423 UV Lamp for PW-21
Accessories for UVC- 01/11/21
Cat. No. Description
CHE4435 Lighting Lamp for UVC-01
CHE4436 Lighting Lamp for UVC-11
CHE4410 Lighting Lamp for UVC-21
CHE4434 UV Lamp for UVC-01
CHE4431 UV Lamp for UVC-11
CHE4427 UV Lamp for UVC-21
HEPA Filter
Pre-Filter
Only for PW Series
PW and UVC Series
UV Lamp
Fluorescent Lamp