G60 Modular Patient Monitor  Plug-and-play mo dular desi gn pro vides patient care exibility  12.1 color TFT display Maximum 8 wa vefo rm displa y 7-lead ECG or 12-lead ECG simultaneous displa y  ST and arrhyt hmia analys is  Hemodynamic, Oxygenation, V entilation, Drug Dose Calculations  OxyCRG dynami c trend displa y  Bed-to-bed vie w  Applications from neonate to adult  LAN networking capability to UT4800 c entral monito ring system

Upload: suhaimi-rosti

Post on 21-Feb-2018

235 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: G60 Patient Monitor

7/24/2019 G60 Patient Monitor

http://slidepdf.com/reader/full/g60-patient-monitor 1/2

G60 Modular Patient Monitor  ● Plug-and-play modular design provides patient care exibility

 ● 12.1” color TFT display

● Maximum 8 waveform display

● 7-lead ECG or 12-lead ECG simultaneous display

 ● ST and arrhythmia analysis

 ● Hemodynamic, Oxygenation, Ventilation, Drug Dose Calculations

 ● OxyCRG dynamic trend display

 ● Bed-to-bed view

 ● Applications from neonate to adult

 ● LAN networking capability to UT4800 central monitoring system

Page 2: G60 Patient Monitor

7/24/2019 G60 Patient Monitor

http://slidepdf.com/reader/full/g60-patient-monitor 2/2

 

Eschmann Critical Care15 Peter RoadLancing Business Park

LancingWest Sussex

BN15 8TJ T +44 (0)1903 875700

F +44 (0)1903 875789

 

 

Multi-parameter Module(dual-slot)ECG (Philips ECG technology):

Lead type:  3-lead or 5-lead selectable, optional12-lead

Lead selection:

  3-lead: I, II, III

  5-lead: I, II, III, aVR, aVL, aVF, V  12-lead: I, II, III, aVR, aVL, aVF, V1, V2,

V3, V4, V5, V6

HR measurement range:

Adult/Pediatric: 15 bpm - 300 bpm

Neonate: 15 bpm - 350 bpm

Accuracy:  ±1 bpm or ±1 %, whichever is greater

ST measurement range: -2.5 mV - +2.5 mV

Accuracy:  ±0.05 mV or ±5 %, whichever

is greater

Arrhythmia:  21 calls

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s

Gain selection:  x 1/4, x 1/2, x 1, x 2, x 4, Auto

Pacemaker detection:  Yes

Protection: Against electrosurgical interference

and debrillation.

ECG analog output

Non-Invasive Blood Pressure (NIBP)

Method: Automatic oscillometric

Parameters:  SYS/DIA/MAP/Pulse Rate

Operating mode:  Manual/Auto/STAT

Auto measure intervals:1-10, 15, 30, 60, 90, 120, 180, 240, 480 minutes

Units:  mmHg/kPa

Cuff pressure range:

Adult/Pediatric: 0 - 300 mmHg (0 kPa - 40.0 kPa)Neonate: 0 - 150 mmHg (0 kPa - 20.0 kPa)

Measurement and alarm range:

SYS: Adult /Pediatric: 30 - 255 mmHg (4.0 kPa - 33.9 kPa)

  Neonate: 30 - 135 mmHg (4.0 kPa - 18.0 kPa)DIA: Adult/Pediatric: 10 - 220 mmHg (1.3 kPa - 29.3 kPa)

  Neonat e: 10 - 110 mmHg (1.3 kPa - 14.7 kPa)

Accuracy:  Max. Mean Error: ±5 mmHg (±0.7 kPa)

  Max. Std. Deviation: 8 mmHg (1.1 kPa)

PR measurement range: 40 bpm - 240 bmp

Accuracy:  ± 2 bpm or ±2 %, whichever is greater

Over-pressure protection: Yes

SpO2(Philips SpO

2 technology)

Measurement range:  0 - 100 %

Accuracy:  70 - 100 %, depends on sensor  0 - 69 %, unspecied

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s

PR measurement range: 30 - 300 bpm

Accuracy: ±1 bpm or ±2 %, whichever is greater

Respiration (RESP)

Measurement method:  Thoracic impedance

Measurement range:  Adult: 0 - 120 rpm  Pediatric: 0 - 150 rpm

  Neonate: 0 - 170 rpm

Accuracy:  ±1 rpm in the range of 0 - 70 rpm

  ±2 rpm in the range of 71 - 120 rpm

  ±3 rpm in the range of 121 - 170 rpm

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s

Gain selection: x 1/2, x 1, x 2

Lead selection: RA - LA, RA - LL, LA - RL, LL - RL

Apnea alarm: Yes, 10 - 60 s

Temperature (TEMP, 2-channel)

Measurement range: 0°C - 50°C (32°F - 122°F)

Resolution: 0.1°C (0.2°F)Accuracy: ±0.1°C (±0.2°F)

Units: °C/°F

IBP (2-channel, optional)

Parameters:  SYS/DIA/MAP/Pulse Rate

Measurement range: -50 - 400 mmHg (-6.6 kPa - 53.2 kPa)

Accuracy: ±4 mmHg (±0.53 kPa) or ±4 % ofreading, whichever is greater

 Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s,50 mm/s

Resolution: 1 mmHg (0.13 kPa)

Units: mmHg/kPa

Transducer sensitivity:  5 uV/V/mmHg

Optional Modules

etCO2 Module (single-slot)

Method: Microstream, infrared absorption

Parameters:  RR, etCO2, inCO

2

Measurement range:  0 - 99 mmHg (0 - 13.2 kPa)

Accuracy:

0 - 38 mmHg (0 kPa - 5.06 k Pa): ±2 mmHg (±0.3 kPa)39 - 99 mmHg (5.19 kPa - 13.2 kPa): ±5 % of reading + 0.08 %

for every 1 mmHg above 38 mmHg (5.2 kP a - 13.2 kPa: ±5 %of reading + 0.08 % for every 0.13 kPa above 5.1 kPa)

Resolution:  1 mmHg (0.13 kPa)

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s

Respiration rate:  0 - 150 rpm

Accuracy:  ± 1 rpm in the range of 0 - 70 rpm  ± 2 rpm in the range of 71-120rpm

  ± 3 rpm in the range of 121 -150 rpm

Units:  mmHg/kPa

Dual IBP Module (single-slot)

Parameters:  SYS/DIA/MAP/Pulse Rate

Measurement range: -50 - 400 mmHg

(-6.6 kPa - 53.2 kPa)

Accuracy:  ±4 mmHg (±0.53 kPa) or ±4 % of

reading, whichever is greater

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s,

50 mm/s

Resolution:  1 mmHg (0.13 kPa)

Units:  mmHg/kPa

Transducer sensitivity:  5 uV/V/mmHg

Cardiac Output Module (single-slot)

Measurement method:  Right heart thermodilution

Measurement range:  0.1 l/min – 20.0 l/min

Accuracy: ±0.2 l/min or ±10 %, whichever

is greater

Blood temperature range: 27°C - 43°C (80.6°F - 109.4°F)

Accuracy:  ±0.1°C

Injection Temperature:  0°C - 27°C (32°F - 80.6°F)

Units:  °C/°F

Multi-gas Module (triple-slot)

(Manual Agent ID or Auto Agent ID with O2)

 Waveform speed:   6.25 mm/s, 12.5 mm/s, 25 mm/s,

50 mm/s

O2 measurement range:  0 Vol.% - 100 Vol.%

Accuracy:  0 - 40: ± 1 Vol.%  40 - 60: ± 2 Vol.%

  60 - 80: ± 3 Vol.%  80 - 100: ± 4 Vol.%

N2O measurement range:  0 Vol.% - 100 Vol.%Accuracy:  0 - 20: ± 2 Vol.%

  20 - 100: ± 3 Vol.%

CO2 measurement range:  0 % - 10 % (0 mmHg - 100 mmHg)

Accuracy:  0 - 1: ± 0.1 %

  1 - 5: ± 0.2 %  5 - 7: ± 0.3 %

  7 - 10: ± 0.5 %  > 10: unspecied

Enurane / Isourane/ Halothane measurement range:

  0 Vol.% - 5 Vol.%

Accuracy:  0 - 1: ± 0.15 %

  1 - 5: ± 0.2 %  > 10: unspecied

Sevourane measurement range:

  0 Vol.% - 8 Vol.%

Accuracy:  0 - 1: ± 0.15 %  1 - 5: ± 0.2 %

5 - 8: ± 0.4 %  > 8: unspecied

Desurane measurement range:  0 Vol.% - 18 Vol.%

Accuracy:  0 - 1: ± 0.15 %

  1 - 5: ± 0.2 %  5 - 10: ± 0.4 %

  10 - 15: ± 0.6 %  15 - 18: ± 1%

  > 18: unspecied

Flexible Module Server (optional)

8 module slots

1.1m connection cable to monitor

Recorder (optional)

Type: Built-in thermal recorder, 3 channels

Print mode:  Real-time recording, timed recording,

alarm-activated recording

Print speed:  Auto, 12.5 mm/s, 25 mm/s, 50 mm/s

Display Type: Color TFT LCD

Size:  12.1”

Resolution:  800 x 600 pixels

Channels:  Max. 8 channels (14 waveform channels

with 12-lead ECG displayed)

Power Supply

AC power input : 100 V - 240 VAC, 50/60 Hz

Battery (optional):  Li-Ion battery, ≥2 hours of continuousmonitoring (with ECG, SpO

measurement and NIBP measured every15 minutes)

 Weight & Dim ensio ns:

Main unit net weight:  Approx. 7 kg (with Multi-parameterModule, Recorder, without battery)

Main unit dimensions: 334 mm (W) x 175 mm (D) x

296 mm (H)

FMS net weight:  Approx. 2 kg (without modules)

FMS dimensions:  437 mm (W) x 138 mm (D) x134 mm (H)

Safety Approval & Quality System

Safety standard: IEC 60601-1

Quality system: ISO 9001 & ISO 13485 certiedCE marking according to the Council Directive 93/42/EEC

Data Review and Storage:

1600 sets trend table1200-hour trend data of all par ameters (with Data Manager

function)120-minute full disclosure ECG 1 waveform review (with Data

Manager function)200 sets alarm events

200 sets arrhythmia events

External Interface (standard)

Digital video output, FMS interface, Nurse Call, LAN, USB

 

Specifcations subject to change without notice