Prices and data subject to change without notice www.geelectrical.com BuyLog Catalog 5-1 Insulated Case Circuit Breakers 5 INSULATED CASE CIRCUIT BREAKERS Publications and Reference: See Section 21 for a list of additional product-related publications Rev. 12/04 Section 5: Insulated Case Circuit Breakers Insulated Case Circuit Breakers Publication References ......................................................................5-2 Power Break‚ I and II Selection Guide ............................................5-4 Power Break II Features ................................................................................................5-5 Trip Unit Features ................................................................................5-7 Trip Unit Characteristics ....................................................................5-8 Product Number Nomenclature System .......................................5-10 Interrupting Capacity and Withstand Ratings ..............................5-13 How to Order ......................................................................................5-14 Basic Frame Selection .....................................................................5-15 Stationary and Draw-out Switch Selection ..................................5-16 Trip Unit Selection – How to Order ................................................5-17 Enhanced MicroVersaTrip Rating Plug Selection .......................5-19 Power Break Insulated Case Circuit Breakers In 1965 GE pioneered the design of insulated case circuit breakers when it introduced the original Power Break circuit breaker. Power Break I offered rugged system protection for heavy-duty applications in a reliable, cost-effective insulated case. Power Break I can still be equipped with either a dual magnetic trip for dc applications or the latest in electronic trip protection for ac system protection and moni- toring. When GE introduced Power Break II, the original benchmark for performance and reliability was dramatically improved for ac systems, while maintaining the original insulated case circuit break- er features in a contemporary, compact physical envelope. Today, GE continues to offer both lines of breakers to cover the range of ac and dc power system protection and control needs as well as the continuing needs of the systems originally designed around these capable circuit breakers. Neutral Current Sensors and POWER LEADER Accessories.......................................................5-21 Stationary and Draw-out Breaker Accessories ..........................5-22 Stationary Breaker Mounting Kits..................................................5-27 Draw-out Breakers and Accessories ............................................5-29 Power Break I Circuit Breakers Ratings and Trip Characteristics ....................................................5-31 Draw-out Breakers ...........................................................................5-32 How to Order ......................................................................................5-33 Ratings and Trip Characteristics ....................................................5-34 Trip Unit Features ..............................................................................5-36 Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—Technical Data, Trip Unit Characteristics..............5-37 Power Break I Circuit Breakers with MagneTrip Unit—How to Order ...................................................5-38 Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—Frame Selection .........................................................5-40 Stationary Switches, Draw-out Switches.....................................5-41 Frame Modification Features ..........................................................5-42 Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—How to Order ..........................5-43 Rating Plug Selection .......................................................................5-45 Accessories........................................................................................5-46 Enclosures ..........................................................................................5-54

Upload: others

Post on 06-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-1

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Publications and Reference: See Section 21 for a list of additional product-related publications

Rev. 12/04

Section 5: Insulated Case Circuit Breakers

Insulated Case Circuit BreakersPublication References......................................................................5-2Power Break‚ I and II Selection Guide............................................5-4

Power Break II Features ................................................................................................5-5Trip Unit Features ................................................................................5-7Trip Unit Characteristics ....................................................................5-8Product Number Nomenclature System.......................................5-10Interrupting Capacity and Withstand Ratings..............................5-13How to Order......................................................................................5-14Basic Frame Selection .....................................................................5-15Stationary and Draw-out Switch Selection..................................5-16Trip Unit Selection – How to Order ................................................5-17Enhanced MicroVersaTrip Rating Plug Selection .......................5-19

Power Break Insulated Case Circuit BreakersIn 1965 GE pioneered the design of insulated case circuit breakerswhen it introduced the original Power Break circuit breaker. PowerBreak I offered rugged system protection for heavy-duty applicationsin a reliable, cost-effective insulated case. Power Break I can still beequipped with either a dual magnetic trip for dc applications or thelatest in electronic trip protection for ac system protection and moni-toring. When GE introduced Power Break II, the original benchmarkfor performance and reliability was dramatically improved for acsystems, while maintaining the original insulated case circuit break-er features in a contemporary, compact physical envelope.

Today, GE continues to offer both lines of breakers to cover therange of ac and dc power system protection and control needs aswell as the continuing needs of the systems originally designedaround these capable circuit breakers.

Neutral Current Sensors and POWER LEADER Accessories.......................................................5-21

Stationary and Draw-out Breaker Accessories ..........................5-22Stationary Breaker Mounting Kits..................................................5-27Draw-out Breakers and Accessories ............................................5-29

Power Break I Circuit BreakersRatings and Trip Characteristics ....................................................5-31Draw-out Breakers ...........................................................................5-32How to Order......................................................................................5-33Ratings and Trip Characteristics ....................................................5-34Trip Unit Features ..............................................................................5-36Power Break I Circuit Breakers with Enhanced

MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—Technical Data, Trip Unit Characteristics..............5-37

Power Break I Circuit Breakers with MagneTrip Unit—How to Order ...................................................5-38

Power Break I Circuit Breakers with Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—Frame Selection .........................................................5-40

Stationary Switches, Draw-out Switches.....................................5-41Frame Modification Features ..........................................................5-42Power Break I Circuit Breakers with

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Units—How to Order..........................5-43

Rating Plug Selection .......................................................................5-45Accessories........................................................................................5-46Enclosures ..........................................................................................5-54

probe
Section Update November
Page 2: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-2 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RSInsulated Case Circuit Breakers

Rev. 12/04

UL/CSA File NumbersPower Break Breakers ................................................E11592/LR10263MicroVersaTrip Plus and MicroVersaTrip PM

and Power+ Trip Units ...............................................E11592/LR10263MicroVersaTrip and Power+ Rating Plugs ...............E11592/LR10263Accessories ...................................................................E57253/LR10263Molded Case Switches................................................E57546/LR16271

Power Break II Time Current Curve-Numbers

Power Break II Instructions for Breakers and AccessoriesPower Break II Circuit Breakers–

800-4000 A frames, 240-600 Vac..........................................GEH-6270Power Break II Circuit Breakers–

Draw-Out 800-4000 Ampere Frames ..................................GEH-6271Power Break II Circuit Breakers–

Draw-Out Substructure ........................................................GEH-6272Power Break II Circuit Breakers–Trip Unit .........................GEH-6273Power Break II Circuit Breaker Accessories–

Auxiliary Switch Module......................................................GEH-6274Power Break II Circuit Breaker Accessories–

Bell Alarm-Alarm Only..........................................................GEH-6275Power Break II Circuit Breaker Accessories–

Door Interlock ........................................................................GEH-6276Power Break II Circuit Breaker Accessories–

Lug Kits and T Studs .............................................................GEH-4546Power Break II Circuit Breaker Accessories–

Bell Alarm with Lockout .......................................................GEH-6278Power Break II Circuit Breaker Accessories–

Key Interlock Provision ........................................................GEH-6279Power Break II Circuit Breaker Accessories–

Mechanical Counter .............................................................GEH-6280Power Break II Circuit Breaker Accessories–

Motor Operator Mechanism................................................GEH-6281Power Break II Circuit Breaker Accessories–

Push Button Cover ................................................................GEH-6282Power Break II Circuit Breaker Accessories–

Remote Close .........................................................................GEH-6283Power Break II Circuit Breaker Accessories–

Shunt Trip................................................................................GEH-6284Power Break II Circuit Breaker Accessories–

Undervoltage Release ..........................................................GEH-6285Power Break II Circuit Breaker Accessories–

Walking-Beam Interlock ......................................................GEH-6286TVRMS2 Test Kit.....................................................................GEK-97367Power Break II Circuit Breaker Accessories–

Draw-Out Substructure Secondary Disconnect..............GEH-6460

Insulated Case Circuit BreakersAssociated Devices and Accessories

Functions Curve No.

Ground Fault GES-9890

GES-9889Enhanced MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units

Long-time Delay with Instantaneous orLong-time Delay, Short-time Delay with Instantaneous

Power Break II Circuit Breaker Accessories–Draw-Out Substructure Rail Kit ..........................................GEH-6440

Walking Beam Interlock 800A, 1600A, 2000A .....................GEH-6286Walking Beam Interlock 2500-3000A......................................DEH-009Walking Beam Interlock 4000A ...............................................DEH-010Draw Out Mechanical Interlock 800-2000A ..........................DEH-011Draw Out Mechanical Interlock 2500-4000A ........................DEH-012Neutral Kit ...................................................................................DEH-024Hidden “ON” Button..................................................................DEH-025High Voltage Shunt Trip ..........................................................GEH-6519High Voltage Under Voltage Release...................................GEH-6520Under Voltage Release Time Delay Relay ...........................GEJ-4699

Power Break II Circuit Breakers Trip UnitsPower+ Trip Unit ........................................................................DEH-049

Power Break II Circuit BreakersRating Plugs..............................................................................GEH-5933Enclosures 800-2000A.............................................................GEH-6503

Power Break II Insulated Case Switches800-4000A, 240-600 Vac.........................................................DEH-40380Power+ Control Units............................................................DEH-40381

Power Break I Time Current Curve NumbersFunctions Frame Curve No.

Long-time Delay with Instantaneous or Long-time Delay, Short-time Delay with Instantaneous

800A-4000A GES-9909

Ground Fault 800A-4000A GES-9911

1200A-1600A GES-6164

2000A GES-6165

2500A GES-6166

3000A-4000A GES-6167

1200A-1600A GES-6168

2000A GES-6169

2500A GES-6170

3000A-4000A GES-6171

MagneTrip™ Trip Unit

Long-time Delay with Instantaneous

Long-time Delay, Short-time Delay

MicroVersaTrip Plus™ and MicroVersaTrip PM™ Trip Units

Page 3: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-3

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Publications and Reference: See Section 21 for a list of additional product-related publications

Rev. 12/04

GE Power Break I Technical PublicationsFor more information on these products, order publications listed inSections 21 and 22.

General Instructions, Breakers and AccessoriesCircuit Breaker Construction Details (800-4000A) ..............GEF-4458MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit....GEH-6273MicroVersaTrip Plus and MicroVersaTrip PM Rating

Plugs for Power Break and AKR Circuit Breakers ..........GEH-5933MagneTrip Trip Unit (2500-3000A) .........................................GEH-4658Power Break Circuit Breaker (800-2000A)

General Information, Accessory Installation ...................GEH-4693Power Break Circuit Breaker (2500-4000A)

General Information, Accessory Installation ...................GEH-4694Power Break Draw-out Breakers (800-4000A) ...................GEH-4698

Field Installed Accessories and OptionsPadlock Accessory (2500-4000A)..........................................GEH-3394Bell Alarm For MagneTrip (2500-4000A) ..............................GEH-3403Terminal Board For Accessories (800-4000A) ....................GEH-3407Circuit Breaker Enclosure (800-4000A) ................................GEH-3498Lug Kits (2500-4000A) ..............................................................GEH-4303Key Interlock Mounting (800-2000A) ....................................GEH-4324Key Interlock Mounting (2500-4000A) ..................................GEH-4341Bell Alarm For MicroVersaTrip RMS-9

(2500-4000A) ...........................................................................GEH-4358Mechanical Interlock-Stationary Breakers

(800-4000A) .............................................................................GEH-4383Remote Close Option (2500-4000A).......................................GEH-4544Lug Kits (800-2000A) ................................................................GEH-4546Power Break Draw-out Secondary Disconnect

(800-4000A) .............................................................................GEH-4696Power Break Draw-out Substructure,

Accessories (800-4000A)......................................................GEH-4697Power Break Draw-out Position Switch ...........................DEH-40528Power Break “Off” Button Activated

Motor Cutoff Switch (2500-4000A)......................................GEH-4699Power Break Draw-out Mechanical Interlock

(800-4000A) .............................................................................GEH-5006Digital Test Kit MicroVersaTrip-Trip Units

(Product Number TVRMS2) ...............................................GEK-97367Portable Battery Pack (Product Number TVPBP) ................DEJ-001

Replacement PartsReplacement Trip Units ..........................................................GEH-6303

Insulated Case Circuit BreakersAssociated Devices and Accessories

Page 4: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-4 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I and II Selection Guide

Insulated Case Circuit Breakers

Circuit Breaker Trip Types

Envelope Size MicroVersaTrip Molded Max IC @ Max Voltage Max Voltage Max Frame(Amperes) Power+ Plus/PM MagneTrip Case Switch 480V (kA) Rating (ac) Rating (dc) (Amperes)

Power Break II800 X X 65 600 8001600 X X 65 600 2000

Standard 2000 X X 65 600 20003000 X X 100 600 30004000 X X 100 600 4000800 X X 100 600 8001600 X X 100 600 2000

Hi-Break 2000 X X 100 600 20003000 X X 150 600 30004000 X X 150 600 4000800 X 301 600 8001600 X 401 600 2000

Molded 2000 X 401 600 2000Case Switch 2500 X 421 600 2500

3000 X 421 600 30004000 X 421 600 4000

Power Break I800 X X 65 600 250 8001600 X X 65 600 250 2000

Standard 2000 X X 65 600 250 20003000 X X 100 600 250 30004000 X X 100 600 250 4000800 X X 100 600 600 8001600 X X 100 600 600 2000

Hi-Break 2000 X X 100 600 600 20003000 X X 150 600 600 30004000 X X 150 600 600 4000

Special 3000 X 750 750 700 3000Hi-Break 4000 X 750 750 700 4000

800 X 252 600 800

Molded1600 X 302 600 2000

Case Switch 2000 X 302 600 20002000 X 422 600 20003000 X 422 600 25003000 X 422 600 30004000 X 422 600 4000

1Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-13 for withstand ratings.2Molded case switch ratings are short time @ 600Vac, not interrupting current. See page 5-34 for withstand ratings.

The interruption ratings and voltages shown in the table are maxi-mum ratings. A circuit breaker of the type given in the left-handcolumn may be applied at the given circuit voltage in any electricaldistribution system where the available fault current at the loadterminals of the breaker does not exceed the value in the table.That circuit breaker type may also be applied at intermediatevalues of circuit voltage provided the available fault current atthe load terminals of the breaker does not exceed the value inthe table for the higher value of voltage.

probe
November Page Update
Page 5: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-5Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersThe Insulated Case Circuit Breaker—GE pioneered the design andcreated the name in 1965. GE Power Break II insulated case circuitbreakers are the latest in reliable, flexible and easy-to-use circuitprotection.

Power Break II circuit breakers are UL Listed, CSA and IEC-947-2Certified for up to 200,000 amperes, at 240 volts rms symmetricalinterrupting capacity without fuses or current limiters. These newinsulated case circuit breakers rated 200-4000A can be applied onac power systems through 600 volts. All breaker frames, except4000A stationary, are UL Listed to carry 100% of their ampere rating continuously. All frames are suitable for reverse feeding.

All Power Break II circuit breakers are available in two levels ofinterrupting capacity—”standard break” and “Hi-Break”breakers. Each interrupting level is available in both stationaryand draw-out construction, with a full complement of control andsignaling accessories.

Standard break breakers are designed to meet the majority ofapplication requirements, calling for moderate levels of available short-circuit current.

Hi-Break breakers are specially designed to withstand the stresses,and safely interrupt high levels of short-circuit current found in someapplications (from 65 to 200 kA rms symmetrical amperes—depend-ing on voltage).

Greater Convenience and Operational SafetyThe controls and status indicators you need most are readilyaccessible. The flush-mounted handle, ON/OFF buttons, rating plugtest receptacle, bell alarm reset buttons — with or without lockout— are easily reached and all are double-insulated from live compo-nents. And, for added security, a standard padlock device lets youprevent accidental or unauthorized closing of the breaker.

Power Break II circuit breakers are versatile and designed for awide variety of applications including temperature insensitive tripunits, push-to-open and close control, charge-after-close operation,3 cycle closing, UL listed (file E 11592) field installable accessoriessuitable for 50/60 Hz. All accessories and control wiring are prewiredto dedicated, secondary terminal points on each breaker.

Quick, Error-Free Installation of Universal AccessoriesDrop-in bell alarm, bell alarm with manual reset lockout, shunt trip,shunt trip with lockout, and undervoltage release install in seconds.No special tools. No breaker disassembly. Just slide them into place.The modules are universal across all frame sizes and each ismechanically keyed to its compartment so you make the rightconnection, every time. These accessories are field installableand upgradable.

GE’s innovative, modular, drop-in accessories provide the ultimatecustomer solution for field customization:

UL Listed—Accessory combination (one each) shunt trip, undervoltage

release, bell alarm (alarm only), bell alarm with lockout.—Rated 12-250 Vdc through 12-240 Vac, continuous duty.

Complete installation in seconds without special tools, breakerdisassembly or adjustment

—The user can select how protective trip unit functions, the shunttrip (with or without lockout), and UVR accessories interfacewith the bell alarm and bell alarm with lockout accessories: Anovercurrent, shunt trip, or UVR trip can be set to actuate thebell alarm or bell alarm with lockout. Any combination of outputactions based on inputs can be selected.

—Shunt trip and undervoltage trip targets are clearly displayed bythe trip unit LCD.

Pre-wired wire harness makes field installation a snap for:—Motor operator with remote charge indicator—Auxiliary switches, up to 12-stage maximum—Remote close solenoid

Additional field-installable accessories including:—Kirk Key locks (4 maximum)—Limited access ON/OFF cover—Mechanical operations counter—Door interlock—Walking beam interlock for stationary and draw-out breakers.

Ratings for Global Use—Performance ratings include IEC947-2 certification.

Power Break II Circuit BreakersFeatures

Page 6: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-6 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersTrip Unit Features

Power+ Trip Unit SystemsThe Power+ trip unit system for Power Break II insulated casebreakers consist of the trip unit, the trip actuator, current sensorsand rating plugs. The term “trip unit system” applies to the combina-tion of these four components which form the solid-state circuitbreaker tripping system.

Power+ trip units provide a complete range of standard and optionalovercurrent and ground-fault protective functions.

True RMS SensingThe Power+ trip unit continues touse GE’s proven technique ofmeasuring true rms currents ofboth sinusoidal and harmonicallydistorted waveforms. The frequentsampling (48 times per cycle perphase) allows precise calculationsof true rms current. The samplingrate allows waveform measure-ments up to the 11th harmonic. GE’strue rms sensing avoids potentialunderprotection or overprotectionproblems associated with peak-sensing tripping systems.

Accessory IntegrationFour accessories are integrated through the Power+ trip unit. Drop-in shunt trip (with or without lockout), bell alarms (with or withoutlockout) and the undervoltage release modules fit into keyed pock-ets. They operate through the trip units, and not through any externalmechanisms. All accessory wiring is pre-wired to secondary termi-nals, and no user wiring is necessary. When activated, the shunt trip(with or without lockout) and undervoltage release modules send asignal to the trip unit to energize the trip actuator and open thebreaker.

Trip Target Module (Optional)View Button: Press the VIEW button to check the trip unit status.

Reset Button: Press the RESET button to clear any target that is set.

Battery check: Target modules use two standard, 3V, 16mm x 1.6mm,lithium batteries for viewing target information. Battery life dependsupon use, but may be estimated at one year. When the batteries areenergized, depressing the VIEW button will illuminate either a settarget LED, i.e., LT or the BAT LED. Once target indicators arecleared, battery status is indicated by the BAT LED. Replacementbatteries include Panasonic CR1616, Eveready E-CR1616BP, orDuracell DL1616B, which may be purchased commercially.

Long-time pickup: The long-time pickup indicator moves through twotransitions. As the current in any phase reaches 95% of its setpoint;the LTPU LED begins to flash. As current increases, flashing fre-quency increases, until 100% of the pickup point is reached. At thatmoment, the LTPU LED stays on continuously until the long-timedelay times out. Once the breaker has tripped on long-time, the OVLtarget will be stored in memory. To view the trip, press the VIEWbutton. To clear the target, press the RESET button.

Short-time and instantaneous trips: Short-time and instantaneoustrips share the same trip target. The LTPU LED is not illuminated,since the time intervals between pickup and tripping are too shortfor either function. Once the breaker has tripped on short-time orinstantaneous, the short target will be stored in memory. To view thetrip, press the VIEW button. To clear the target, press the RESET button.

Ground fault trip (Target02 only): The trip target for a ground faulttrip is the GF LED. To view the trip, press the view button. To clearthe target, press the RESET button.

Health monitor: Trip unit health status “okay” is illustrated by slowblinking of the LTPU LED. It may be seen by depressing and holdingthe VIEW button. Sufficient power must be supplied to the trip unitvia external test kit, power pack, or current transformers for thehealth monitor to be operational.

Standard and Optional Protective FunctionsStandard and optional protective functions are available for Power+trip units. The breaker settings are programmed in multiples of “X”(rating plug ampere values), “S” (current sensor ampere ratingvalues), and “C” (the long-time setting in amperes—multiply long-time setting by rating plug ampere rating).

Standard—Adjustable Long-Time (L) Pickup, 0.5 - 1.0X, with four delay bands.—Adjustable Instantaneous (I) Pickup, 1.5 - 15X.1

Options—Overload, Short Circuit, and Short-Time local trip indicators with

overload pickup warning and health monitor.—Adjustable Short-Time (S) Pickup, 1.5 - 9.0C, and delay (3 bands)

with I2t ON/OFF selection.—Adjustable Ground Fault (G) Pickup, 0.2 - 0.6S, and delay1

(3 bands) with I2t ON/OFF selection and trip indicator.—Upgradeable Ground Fault function with use of appropriate

ground fault rating plug.1Limited by breaker frame size above 2000A.Power+ Trip Target Module

Page 7: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-7Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM TripUnits have been specifically designed to integrate with the

extensive capabilities offered by Power Break II circuit breakers.

Power Break II Circuit BreakersTrip Unit Features

Two Choices of Advanced, Digital Solid-State Trip UnitsEnhanced MicroVersaTrip Plus and MicroVersaTrip PM trip unitsgive you two new ways to monitor and control the Power Break IIbreaker with unprecedented ease. Through the simple keypad, thetrip unit lets you program and display a variety of functions includingtripping characteristics, remote communications, status informationand protective relaying, and allows integration with GE POWERLEADER Power Management Systems. The trip unit display alsoallows viewing of many standard metering parameters as well aspickup alarms, trip target indications and fault status information.

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM tripunits continue to use GE’s proven technique of measuring true rmscurrents (and voltages for MicroVersaTrip PM trip units) of bothsinusoidal and harmonically distorted waveforms. The frequentsampling (64 times per cycle) allows precise calculations of truerms current. The sampling rate allows waveform measurements upto the 31st harmonic to achieve accuracies of 99%. GE’s true rmssensing avoids potential underprotection or overprotection problemsassociated with peak-sensing tripping systems.

The enhanced trip unit design includes a wide range of functionsand adds many new features:

UL Listed Field-InterchangeableNon-volatile trip targets display/Cold setup capability

—Replaceable long-life batteries provide trip target indicationsand cold setup capability—without the need for external poweror a battery pack.

Trip operations counter—The number of long-time, short-time, instantaneous and ground

fault trips are individually counted and displayed.

Trip information—On overcurrent faults, the trip unit displays fault pickup, the type

of fault, the magnitude of the fault current and the phase thefault occurred on.

—Display indicates when a shunt trip or undervoltage release triphas opened the breaker.

New display—Ergonomic, 5-button keypad—New targets with international symbols—High-resolution LCD display for local 3-phase ammetering—New status and setup displays for greater ease of use—True rms sensing for accurate response to high harmonic con-

tent waveforms for Long-Time, Short-Time, and Ground Faultprotection.

—50/60 Hz operation.—Interchangeable, UL Listed trip units and rating plugs with test

set jack for TVRMS2 test set.—EMI immunity per ANSI C37.90.

Features exclusive to MicroVersaTrip PM Trip UnitsCommunications

—All information can be viewed on the LCD display orcommunicated over a POWER LEADER PowerManagement System network.

Demand/peak demand—The trip unit can display a rolling average of power demand

and peak power demand at user-selected intervals from 5 to60 minutes.

Local and remote metering—Amps, volts, frequency—Real power, total power—Accumulated energy

Protective relays include:—Current and voltage unbalance—Overvoltage—Undervoltage—Power reversal—Power reversal direction setup

Page 8: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-8 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power+ Trip Unit Characteristics

Power+ Trip Unit Characteristics (continued)

Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics

Trip Unit Characteristics (continued)

Pick-Up (Multiple of Sensor Ampere Rating)

Delay With I 2 T In Seconds

Delay 3 With I 2 T Out Seconds

800 1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01

.10, .21, .35

1600 1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01

.10, .21, .35

2000 1.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01

.10, .21, .35

3000 1.5 thru 10.0 in 0.5 increments

1.5 thru 13.0 in 0.5 increments

0.20 thru 0.37 in increments of 0.01

.10, .21, .35

4000 1.5 thru 9.0 in 0.5 increments

1.5 thru 9.0 in 0.5 increments

0.20 thru 0.30 in increments of 0.01

.10, .21, .35

Ground Fault

1.0.44 at 200% of

pick-up at lowerlimit of band

Envelope Size

Adjustable Instantaneous Pick-Up without ST (Multiple of Rating Plug Amperes) (X)

Adjustable Instantaneous Pick-Up with ST (Multiple

of Rating Plug Amperes) (X)

High Range Instantaneous (Multiple of Frame

Short-Time Rating) (H)

1Time delay shown at 600% of current setting at lower limit of band.2Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%.3Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes.4Time delay shown at 200% of pick-up at lower limit of band.

S = Sensor amp ratingC = Long-time current setting (pick-up)H = Short-Time Rating

X = Rating plug amps

Current Setting (C) (Pick-Up) Multiple of Rating Plug Amperes (X) Delay 2 (Seconds)

Pick-up (Multiple of Current Setting) (C) Delay (Seconds)

800 800 200, 400, 800 2.4, 4.9, 9.8, 20

1600 1600 800, 1000, 1600 2.4, 4.9, 9.8, 20

2000 2000 2000 2.4, 4.9, 9.8, 20

2500 1000, 2000, 2500

3000 3000

4000 4000 4000 2.4, 4.9, 9.8, 20

I2 T in1

0.40

I2 T out2

.10, .21, .35

Sensor Rating(Amperes) (S)

Long-Time Short-Time

Envelope SizeFrame Max.

Ampere Rating

2.4, 4.9, 9.8, 20

1.5 thru 9.0 in increments of 0.5

3000

0.5 thru 1.0 in increments of 0.05

Pick-Up (Multiple of Sensor Ampere Rating) Delay 3 (Seconds 3 Bands)

1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60

1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60

1.5 thru 10.0 1.5 thru 15.0 0.20 thru 0.60

3000 1.5 thru 10.0 1.5 thru 13.0 0.20 thru 0.37

4000 1.5 thru 9.0 1.5 thru 9.0 0.20 thru 0.30

2000I2T in4

.10, .21, .35

I2T out2

.10, .21, .35

Envelope SizeAdjustable Instantaneous Pick-Up without ST

(Multiple of Rating Plug Amperes) (X)Adjustable Instantaneous Pick-Up with ST

(Multiple of Rating Plug Amperes) (X)

Ground Fault

Current Setting (C) (Pick-Up) Multiple of Rating Plug Amperes (X) Delay1 (Seconds 4 Bands)

Pick-up (Multiple of Current Setting) (C) Delay (Seconds 3 Bands)

800 200, 400, 800 2.4, 4.9, 9.8, 20

1600 800, 1000, 1600 2.4, 4.9, 9.8, 20

2000 2000 2.4, 4.9, 9.8, 20

3000 2500, 3000 1000, 2000, 2500, 3000 2.4, 4.9, 9.8, 20

4000 4000 4000 2.4, 4.9, 9.8, 20

2000I2T in1

.10, .21, .35

EnvelopeSize

Frame Max. Ampere Rating

Sensor Rating (Amperes) (S)

0.5, 0.6, 0.7, 0.8, 0.9, 0.95 and 1.0

1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 7.0, and 9.0

I2T out2

.10, .21, .35

Long-Time Short-Time

Power Break II Circuit BreakersTrip Unit Characteristics

Page 9: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-9Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

M (Metering) P (Relaying) PM (Metering & Relaying)

Communications —POWER LEADER Communications Bus Link STD STD STD

Amperes (A, kA)2 Selectable Phase Current ±2.5% STD STD STD

Voltage (V) L-L or L-N Volts ±1.5%

Energy (kWh, MWh, GWh) Total Energy Usage on Brkr ±4%

Real Power (kW/MW) L-L or L-N Power ±4%

Total Power (kVA/MVA) L-L or L-N Power ±4%

Frequency (Hz) Circuit Frequency ± 1Hz

Demand & Peak Demand (kW)

Under Voltage Trip—Adjustable pickup 50-90%—Adjustable delay, 1-15 seconds OFF

Over Voltage Trip—Adjustable pickup, 110-150%—Adjustable delay, 1-15 seconds OFF

Voltage Unbalance—Adjustable pickup, 10-50%—Adjustable delay, 1-15 seconds OFF

Current Unbalance—Adjustable pickup, 10-50%—Adjustable delay, 1-15 seconds OFF

Power Reversal—Adjustable pickup, 10-990 kW—Adjustable delay, 1-15 seconds OFF—Power Reversal Direction

Function Description

Trip Unit Suffix

1MicroVersaTrip PM™ functions require 24 Vdc control power.2Ampere reading also standard on MicroVersaTrip Plus trip units.

Power Break II Circuit BreakersTrip Unit Characteristics (continued)

Additional Features and Characteristics Exclusive to the Enhanced MicroVersaTrip PM Trip Unit1

Page 10: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-10 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersProduct Number Nomenclature System

Power Break II Circuit Breaker Product Numbers

Accessory Product Numbers

2Device Product Number requires an extender “R” for field installable kit version only.NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

1High-range instantaneous sensors only available on MicroVersaTrip Plus and MicroVersaTrip PM units.NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

2

Page 11: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-11Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersProduct Number Nomenclature System

1Device Product Number requires an extender “R” for field installable kit version only.NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Power+ Trip Unit Product Numbers

Power+ Rating Plug Product Numbers

Power+ Target Module Product NumbersTARGET00 = Blank insert for Target ModuleTARGET01 = Target Module without ground fault targetTARGET02 = Target Module with ground fault target

1

Page 12: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-12 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersProduct Number Nomenclature System

MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Product Numbers

1Device Product Number requires an extender “R” for field installable kit version only.NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

NOTE: This information is provided only for use interpreting product numbers. It cannot be used to build product numbers.

Rating Plug Product Numbers (MicroVersaTripPlus and PM)

1

Page 13: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-13Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Interrupting Capacity andShort-time Ratings–rms Symmetrical kA

Frame 800A 1600 to 2000A 2500-3000A 4000A

240V 65 85 100 100

480V 65 65 100 100

600V 42 50 85 85

240V 100 125 200 200

480V 100 100 150 150

600V 65 65 100 100

(0.5 sec) 25 40 42 42

ICU— 75 752 85

ICS— 56 452 25

ICW (1 sec) — 40 502 50

1Applies to high range instantaneous or "H" option.2Must use 4000A construction.

UL 489 Ratings, 50/60 Hz Standard

Hi-Break

Short Time1

IEC-947-2 Ratings 415, 50/60 Hz

Complete dimensions and weight information can be found in thePower Break II application guide GET-8052.

Power Break II Circuit BreakersInterrupting Capacity and Withstand Ratings

Stationary and Draw-out Switch Withstand Ratings—rms Symmetrical kA

Maximum Short Circuit Withstand Rating Suitable on 200,000 rms Sym Ampere Fault CircuitShort-time When Protected By Power Break II Circuit Breakers When Protected by Class L Fuses As FollowsRating, rms

Switch Sym Amperes @ Breaker Standard Break Hi-Break Line Side Load SideFrame 600 Vac Max., Frame Size PB II Circuit Breaker PB II Circuit Breaker Max. Fuse Max. Fuse

(Amperes) 500 ms Max. (Amperes) 240 Vac 480 Vac 600 Vac 240 Vac 480 Vac 600 Vac Ampere Rating Ampere Rating

800 30 800 65 65 50 100 100 65 2000 8001600 40 1600 65 65 50 125 100 65 2500 16002000 40 2000 65 65 50 125 100 65 2500 20002500 42 2500 100 100 85 200 150 100 2500 25003000 42 3000 100 100 85 200 150 100 4000 30004000 42 4000 100 100 85 200 150 100 4000 4000

The interruption ratings and voltages shown in the table are maxi-mum ratings. A circuit breaker of the type given in the left-handcolumn may be applied at the given circuit voltage in any electricaldistribution system where the available fault current at the loadterminals of the breaker does not exceed the value in the table.That circuit breaker type may also be applied at intermediate valuesof circuit voltage provided the available fault current at the loadterminals of the breaker does not exceed the value in the table forthe higher value of voltage.

Page 14: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-14 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

How To Order

All Power Break II circuit breakers are available in two levels ofinterrupting capacity – “Standard break” and “Hi-Break” breakers.Each interrupting level is available in both stationary and draw-outconstruction, are suitable for reverse feed, and have a full comple-ment of control and signaling accessories. Power Break II circuitbreaker frames are factory configured for either the enhancedMicroVersaTrip Plus or MicroVersaTrip PM trip units.

1. Determine the type of frame; stationary or draw-out.

2. Determine the required breaker frame, interrupting current level,short-time rating and load requirements. Select the appropriateframe product number and list price on page 5-15.

3. Select the basic enhanced MicroVersaTrip unit to match frameampere rating from page 5-17.

4. Select and price the trip unit suffix from pages 5-17 and 5-18 tomatch the required trip functions. Refer to page 5-8 for trip unitcharacteristics. The trip unit will be installed in the frame.

5. Select and price the required rating plug from page 5-19. Thesensor rating of the frame must match the sensor rating of theplug. Rating plugs will be shipped separately.

6. Internal accessories should be priced separately from pages 5-21through 5-26. Accessories will be installed in the frame. Orderinternal accessories ending with “R” for field installation separately.

7. Select and price externally mounted accessories, such as, push-button cover, key interlock provisions, lug kits and T-studs frompages 5-25 through 5-28.

8. If a draw-out breaker is required, the draw-out substructure ispriced separately from page 5-29. The draw-out breaker is shippedincluding breaker, trip unit, and breaker secondary disconnects forcontrol and accessory wiring. The substructure secondary discon-nects are priced separately from page 5-29.

9. Order substructure accessories, such as shutters, mechanicalinterlocks, racking tool and lifting bar from page 5-30.

Pricing Example–Stationary Breaker GO-245A

2000 ampere stationary frame, 65 kA, 480 V IC rating, 2000 amperesensor, 800 ampere rating plug, trip unit functions including long-time(L), short-time (S), Instantaneous (I), MicroVersaTrip PM trip unit,field installed 120 Vac electric (motor) operator, 24 Vdc remote closesolenoid, 24 Vdc undervoltage release module.

Description Product Number List Price

Frame SSF20B220 $7790.00

Trip Unit and Suffix Adder B220LSIPM $2283.00

Rating Plug TR20B800 $89.00

Electric Operator-field installed SPE120R $1671.001

Remote Close Solenoid-field installed SPRCS024R $286.001

Undervoltage Release-field installed SPUV024DCR $301.001

1GO-245B

Description Product Number List Price

Frame SHD16B210H $10182.00

Trip Unit and Suffix Adder B210LSH $1350.00

Rating Plug TR10B600 $89.00

Electric Operator SPE120 $1838.001

Remote Close Solenoid SPRCS024 $315.001

Shunt Trip SPST024 $328.001

Drawout Substructure SPHDOS16 $1403.001

Substructure Secondary Disconnect SPDOSD36S $283.001

Substructure Shutter Kit SPDSS20 $501.001

Pricing Example—Draw-out Breaker GO-245A

1600 ampere draw-out frame, 100 kA, 480 V IC rating, 1000 amperesensor, 600 ampere rating plug, trip unit functions including long-time(L), short-time (S), high range instantaneous (H), factory installedaccessories including: 120 Vac electric (motor) operator; 24 Vdcremote close solenoid; 24 Vdc shunt trip; draw-out substructure; draw-out secondary disconnect; draw-out shutter.

SSF20B220

Draw-out in Substructure

Power Break II Circuit BreakersHow To Order

Page 15: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-15Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit Breakers Frame

Product1

Number List Price 2Product1

Number List Price 2

200 SSD08*202,H $7085.00 SHD08*202,H $7597.00

400 SSD08*204,H $7085.00 SHD08*204,H $7597.00

800 SSD08*208,H $7085.00 SHD08*208,H $7597.00

800 SSD16*208,H $9205.00 SHD16*208,H $10182.00

1000 SSD16*210,H $9205.00 SHD16*210,H $10182.00

1600 SSD16*216,H $9205.00 SHD16*216,H $10182.00

2000 2000 2000 SSD20*220,H $9604.00 SHD20*220,H $11118.00

1000 SSD25*210,H $10563.00 SHD25*210,H $12229.00

2000 SSD25*220,H $10563.00 SHD25*220,H $12229.00

2500 SSD25*325,H $18234.00 SHD25*325,H $22431.00

3000 3000 SSD30*330,H $22819.00 SHD30*330,H $28125.00

4000 4000 4000 SSD40*440,H $38007.00 SHD40*440,H $46116.00

Circuit Breaker Envelope Size

(Amperes)

Circuit Breaker Frame Size (Amperes)

Standard Break Hi-Break

Current Sensor (Amperes)

30002500

800 800

1600 1600

*Replace * with B for MicroVersa Trip Plus or PM trip unit: or D for Power+™ trip unit.

1Add 'H' suffix to product number for high-range instantaneous protection. Price adder is on trip unit only. High-range instantaneous feature available only with MicroVersaTrip Plus™ or MicroVersaTrip PM™. 2Prices shown include basic "Power+ LI" trip unit but do not include rating plug.380% rated.

Product1 Product1

Number List Price 2 Number List Price 2

200 SSF08*202,H $6006.00 SHF08*202,H $6500.00

400 SSF08*204,H $6006.00 SHF08*204,H $6500.00

800 SSF08*208,H $6006.00 SHF08*208,H $6500.00

800 SSF16*208,H $7342.00 SHF16*208,H $8165.00

1000 SSF16*210,H $7342.00 SHF16*210,H $8165.00

1600 SSF16*216,H $7342.00 SHF16*216,H $8165.00

2000 2000 2000 SSF20*220,H $7790.00 SHF20*220,H $9124.00

SSF25*210,H $8569.00 SHF25*210,H $10035.00

SSB25*210,H $8569.00 SHB25*210,H $10035.00

SSF25*220,H $8569.00 SHF25*220,H $10035.00

SSB25*220,H $8569.00 SHB25*220,H $10035.00

SSF25*325,H $15107.00 SHF25*325,H $18930.00

SSB25*325,H $15107.00 SHB25*325,H $18930.00

SSF30*330,H $19229.00 SHF30*330,H $24101.00

SSB30*330,H $19229.00 SHB30*330,H $24101.00

4000 4000 4000 SSF40*4403 $31714.00 SHF40*4403 $38691.00

1000

2000

2500

3000

Circuit Breaker Envelope Size

(Amperes)

Circuit Breaker Frame Size (Amperes)

Standard Break Hi-Break

Current Sensor (Amperes)

800

1600

3000

800

1600

2500

3000

Basic Frame Selection—Draw-out (without substructure) GO-245A

Basic Frame Selection—Stationary GO-245A

Page 16: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-16 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Molded Case Switch Frames—Stationary GO-245DSwitch Envelope Switch Frame Current Sensor ProductSize (Amperes) Size (Amperes) Rating (Amperes) Number List Price

800 800 800 SSF08Y208 $3119.00

1600 1600 1600 SSF16Y216 $4099.00

2000 2000 2000 SSF20Y220 $4609.00

2500 2500SSF25Y325 $7334.00

3000 SSB25Y325 $7334.00

3000 3000SSF30Y330 $12411.00

SSB30Y330 $10204.00

Molded Case Switch Frames—Draw-out1 GO-245DSwitch Envelope Switch Frame Current Sensor ProductSize (Amperes) Size (Amperes) Rating (Amperes) Number List Price

800 800 800 SSD08Y208 $4061.00

1600 1600 1600 SSD16Y216 $5913.00

2000 2000 2000 SSD20Y220 $6426.00

3000 2500 2500 SSD25Y325 $10204.00

3000 3000 SSD30Y330 $15864.00

4000 4000 4000 SSD40Y440 $25526.00

1Use only with Hi-Break draw-out substructure.

Control UnitsSwitch Envelope Switch Frame Sensor Product List Price Adder,Size (Amperes) Size (Amperes) (Amperes) Number GO-245A

800 800 800 D208 $0.00

D208T2 $160.00

1000 D210 $0.00

1600 1600 D210T2 $160.00

1600 D216 $0.00

D216T2 $160.00

2000 2000 2000 D220 $0.00

D220T2 $160.00

1000 D210 $0.00

D210T2 $160.00

2500 2000 D220 $0.00

3000 D220T2 $160.00

2500 D325 $0.00

D325T2 $160.00

3000 3000 D330 $0.00

D330T2 $160.00

4000 4000 4000 D440 $0.00

D440T2 $160.00

Power Break II Circuit BreakersStationary and Draw-out Switch SelectionHow To Order

How to Order1. Choose a frame from the Molded Case Switch Frame tables below

2. Select a Control Unit from the Control Unit table below. The sensorrating of the control unit should match the sensor rating of theswitch. Choose a control unit with suffix T2 to get ground fault target indication.

3. Select a rating plug from the table to the right.

4. Select all other accessories just as for any Power Break II CircuitBreaker.

Power Break II Rating Plug Selection GO-245APower + Standard Power + Ground Fault

Basic Control Current Rating Rating Plug Rating PlugUnit (Amperes) List Price $89.00 List Price $747.00

400 TR8C400 TR8C400GF450 TR8C450 TR8C450GF

D208 500 TR8C500 TR8C500GF600 TR8C600 TR8C600GF700 TR8C700 TR8C700GF800 TR8C800 TR8C800GF600 TR10C600 TR10C600GF

D210 800 TR10C800 TR10C800GF1000 TR10C1000 TR10C1000GF800 TR16C800 TR16C800GF1000 TR16C1000 TR16C1000GF

D216 1100 TR16C1100 TR16C1100GF1200 TR16C1200 TR16C1200GF1600 TR16C1600 TR16C1600GF1000 TR20C1000 TR20C1000GF1200 TR20C1200 TR20C1200GF

D220 1500 TR20C1500 TR20C1500GF1600 TR20C1600 TR20C1600GF2000 TR20C2000 TR20C2000GF1600 TR25C1600 TR25C1600GF

D325 2000 TR25C2000 TR25C2000GF2500 TR25C2500 TR25C2500GF2000 TR30C2000 TR30C2000GF

D330 2500 TR30C2500 TR30C2500GF3000 TR30C3000 TR30C3000GF1600 TR40C1600 TR40C1600GF2000 TR40C2000 TR40C2000GF

D440 2500 TR40C2500 TR40C2500GF3000 TR40C3000 TR40C3000GF3600 TR40C3600 TR40C3600GF4000 TR40C4000 TR40C4000GF

Ordering Example

1600 ampere drawout switch; field installed 120 Vac electric (motor)operator; 24 Vdc remote close solenoid; 24 Vdc shunt trip; drawoutsubstructure; drawout secondary disconnect; drawout shutter.

Description Product Number List Price

Frame SSD16Y216 $5913.001

Control Unit D216 $0.002

Rating Plug TR16C1600 $89.002

Electric Operator SPE120 $1838.003

Remote Close Solenoid SPRCS024 $315.003

Shunt Trip SPST024 $328.003

Drawout Substructure SPHDOS16 $1403.003

Substructure Secondary Disconnect SPDOSD36S $283.003

Substructure Shutter Kit SPDSS20 $501.003

1GO-245D2GO-245A3GO-245B

probe
Page Update September
Page 17: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-17Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Trip UnitSuffix3

List PriceAdder, GO-245A3

Trip Indicators

Selectable Phase Ammeter

Long-Time(L)

Short-Time(ST)

Inst.(I)

High Inst.(H)

Ground Fault (G)4

GF Zone Interlock (Z1)5

GF/ST Zone Interlock (Z2)5

LI $300.00 • • •

• • •

• • •

• • •

• • •

• • •

• •

• •

• •

• • •

• •

• •

LIG $958.00 •

LIGZ1 $1250.00

LSI $983.00

LSIG $1640.00

LSIGZ1 $1933.00

LSIGZ2 $2225.00

LSH $1350.00

LSHG $2008.00

LSHGZ1 $2300.00

LSHGZ2 $2593.00

5Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B.6Not available on 4000A stationary breaker frame.

Adjustable Instantaneous

Fixed High Range Instantaneous6

3Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix..4For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20.Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List Price $250.00, GO-245A, to the price of the trip unit.

Trip Unit Suffix1

List PriceAdder, GO-245A

L/ST/l 1 GF 2

LI No Price Adder — — • —

LIT1 $140.00 • — • —

LIT2 $160.00 • • • —

LSI $683.00 — — •

LSIT1 $823.00 — ••

LSIT2 $843.00 •••

Adjustable Instantaneous

1For high-range instantaneous or zone selective interlocking select MicroVersaTrip Plus or PM trip units.

2For ground fault-protection, select appropriate rating plug.

Trip IndicatorsLong-Time

(L)Short-Time

(ST)Inst.

(l)

Frame Size

(Amperes)

Frame Rating

(Amperes)Sensor

(Amperes)Power+™Trip Units

Enhanced MicroVersaTripPlus™ and MicroVersaTrip

PM™ Trip Units

200 D202 B202

400 D204 B204

800 D208 B208

800 D208 B208

1000 D210 B210

1600 D216 B216

2000 2000 D220 B220

1000 D210 B210

2000 D220 B220

2500 D325 B325

3000 3000 D330 B330

4000 4000 4000 D440 B440

2500-30002500

800 800

1600-20001600

MicroVersaTrip Plus with Selectable Phase Ammeter—Trip Indicators Standard

Power Break II Trip Unit SuffixPower+ Trip Unit Suffix Selection

Basic Trip Unit Selection

How to Order1. Determine the basic trip unit product number.

2. Determine the type of trip unit, Power+, MicroVersaTrip Plus orMicroVersaTrip PM trip unit.

3. Select the trip unit suffix representing the protection function tocomplete trip unit product number.

4. Determine list price adder to breaker frame list price on page 5-15.

5. Order rating plug separately. Pricing does not include ratingplug price.

6. For replacement trip units, add suffix “R”. Check Elitenet for ListPrice and GO schedule.

Example:1600 Ampere frame, 1000 ampere sensor, Long-time (L). Short-time(S), Instantaneous (I), MicroVersaTrip PM with metering only.Order B210LSIM (List price adder: $1,733.00, GO-245A). The replace-ment trip unit product number would be B210LSIMR.

Power Break II Circuit BreakersTrip Unit SelectionHow To Order

Page 18: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-18 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersTrip Unit Selection (continued)

MicroVersaTrip PM with Metering and Communications—Trip Indicators Standard

MicroVersaTrip PM with Protective Relays and Communications—Trip Indicators Standard

MicroVersaTrip PM with Metering, Protective Relays and Communications—Trip Indicators Standard

Trip Unit Suffix1

List Price Adder, GO-245A1

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (ST)

Inst.(I)

High Inst.(H)

Ground Fault (G) 2

GF Zone Interlock (Z1) 3

GF/ST Zone Interlock (Z2) 3

LIPM $1600.00 •

LIGPM $2288.00

LIGZ1PM $2550.00

LSIPM $2283.00

LSIGPM $2940.00

LSIGZ1PM $3233.00

LSIGZ2PM $3525.00

LSHPM $2650.00

LSHGPM $3308.00

LSHGZ1PM $3600.00

LSHGZ2PM $3893.00

3Requires purchase of Zone Selective Interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B.4Not available on 4000A stationary breaker frame.

Adjustable Instantaneous

Fixed High Range Instantaneous 4

1Add suffix to basic trip unit product number. Make List Price Addition for trip unit suffix..2For single-phase 3 wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately, page 5-20.Defeatable Ground Fault (not UL Listed) is available. Use code GD in place of G. Add List price $250.00, GO-245A, to the price of the trip unit.

Trip Unit Suffix1

List Price Adder, GO-245A1

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (ST)

Inst.(I)

High Inst.(H)

Ground Fault (G)2

GF Zone Interlock (Z1)3

GF/ST Zone Interlock (Z2)3

LIP $850.00 •

LIGP $1508.00

LIGZ1P $1800.00

LSIP $1533.00

LSIGP $2190.00

LSIGZ1P $2483.00

LSIGZ2P $2775.00

LSHP $1900.00

LSHGP $2558.00

LSHGZ1P $2850.00

LSHGZ2P $3143.00

Adjustable Instantaneous

Fixed High Range Instantaneous4

Trip Unit Suffix1

List Price Adder, GO-245A1

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (ST)

Inst.(I)

High Inst.(H)

Ground Fault (G)2

GF Zone Interlock (Z1)3

GF/ST Zone Interlock (Z2)3

LIM $1050.00 •

• •

• •

• •

• •

LIGM $1708.00

LIGZ1M $2000.00

LSIM $1733.00

LSIGM $2390.00

LSIGZ1M $2683.00

LSIGZ2M $2975.00

LSHM $2100.00

LSHGM $2758.00

LSHGZ1M $3050.00

LSHGZ2M $3343.00

Adjustable Instantaneous

Fixed High Range Instantaneous4

Page 19: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-19Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersEnhanced MicroVersaTrip, Rating Plug Selection

Power Break II Rating Plug Selection GO-245AEnhanced

MicroVersaTrip PlusPower+ Trip and Enhanced

Power+ Trip Unit Ground MicroVersaTrip PMUnit Standard Fault Rating Trip Unit

Frame Sensor Current Rating Plugs Plugs Rating PlugsSize Rating Rating List Price, List Price, List Price,

(Amperes) (Amperes) (Amperes) $89.00 $747.00 $89.00

100 TR2C100 TR2C100GF TR2B100200 150 TR2C150 TR2C150GF TR2B150

200 TR2C200 TR2C200GF TR2B200150 – – TR48150

800 200 TR4C200 TR4C200GF TR48200225 TR4C225 TR4C225GF TR48225

400250 TR4C250 TR4C250GF TR48250300 TR4C300 TR4C300GF TR48300400 TR4C400 TR4C400GF TR48400300 – – TR8B300400 TR8C400 TR8C400GF TR8B400450 TR8C450 TR8C450GF TR8B450

800-1600 800 500 TR8C500 TR8C500GF TR8B500600 TR8C600 TR8C600GF TR8B600700 TR8C700 TR8C700GF TR8B700800 TR8C800 TR8C800GF TR8B800400 – – TR10B400

1000 600 TR10C600 TR10C600GF TR10B600800 TR10C800 TR10C800GF TR10B8001000 TR10C1000 TR10C1000GF TR10B1000

1600600 – – TR16B600800 TR16C800 TR16C800GF TR16B800

1600 1000 TR16C1000 TR16C1000GF TR16B10001100 TR16C1100 TR16C1100GF TR16B11001200 TR16C1200 TR16C1200GF TR16B12001600 TR16C1600 TR16C1600GF TR16B1600750 – – TR20B750800 – – TR20B8001000 TR20C1000 TR20C1000GF TR20B1000

2000 2000 1200 TR20C1200 TR20C1200GF TR20B12001500 TR20C1500 TR20C1500GF TR20B15001600 TR20C1600 TR20C1600GF TR20B16002000 TR20C2000 TR20C2000GF TR20B2000400 – – TR10B400600 TR10C600 TR20C600GF TR10B600

1000800 TR10C800 TR20C800GF TR10B8001000 TR10C1000 TR20C1000GF TR10B1000750 – – TR20B750800 – – TR20B8001000 TR10C1000 TR10C1000GF TR20B1000

2500 2000 1200 TR10C1200 TR10C1200GF TR20B12001500 TR10C1500 TR10C1500GF TR20B15001600 TR10C1600 TR10C1600GF TR20B16002000 TR10C2000 TR10C2000GF TR20B20001600 TR25C1600 TR25C1600GF TR25B1600

2500 2000 TR25C2000 TR25C2000GF TR25B20002500 TR25C2500 TR25C2500GF TR25B25001200 – – TR30B12001600 – – TR30B1600

3000 3000 2000 TR30C2000 TR30C3000GF TR30B20002500 TR30C2500 TR30C2500GF TR30B25003000 TR30C3000 TR30C3000GF TR30B30001600 TR40C1600 TR40C1600GF TR40B16002000 TR40C2000 TR40C2000GF TR40B2000

4000 40002500 TR40C2500 TR40C2500GF TR40B25003000 TR40C3000 TR40C3000GF TR40B30003600 TR40C3600 TR40C3600GF TR40B36004000 TR40C4000 TR40C4000GF TR40B4000

MicroVersaTrip and MicroVersaTrip PM Rating Plug

Trip Indicator ProductL/ST/1 Ground Fault Number List Price

– – TARGET00 $60.00

• – TARGET01 $140.00

• • TARGET02 $160.00

Power+ Target Module GO-245APower+ trip units are designed to accept an optional field-installabletarget module. The target module indicates long-time pickup, batterystatus, trip unit health status, and whether a breaker trip wascaused by an overload, a short circuit or a ground fault. Targetmodules are available with or without ground fault indication.

Power+ Trip Target Module

probe
Page Update September
Page 20: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-20 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersNeutral Current Sensors and POWER LEADER Accessories

MicroVersaTrip Portable Test Kit GO-245BThe test kit product number TVRMS2 is a portable, battery-powered,test kit which provides for trip unit health checks and functional tripand no-trip tests. It also provides defeat of the ground-fault functionand can be used in conjunction with high-current test equipment.The test kit can be used to provide +24V power to the trip unit forcold set-up and viewing of trip targets. This test kit is for use withRMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip PM trip units.The kit uses six rechargeable ni-cad or standard alkaline "D" cellssupplied by the customer. Kit can also be powered by 120 Vac source.

Description Product Number List Price

Portable Test Kit TVRMS2 $3000.00

MicroVersaTrip Portable Power Pack GO-245BThe handheld MicroVersaTrip portable battery pack provides anindependent power source for Enhanced MicroVersaTrip Plus andMicroVersaTrip PM trip units as an alternative to the TVRMS2 testset. The power pack is used to power up the trip unit to set or adjusttrip set points when the breaker is on the bench or otherwise notpowered up. It connects to the trip unit through the rating plug testjack. It requires three (3) standard 9 Vdc alkaline batteries (notincluded). Product number TVPBP List Price, $75.00, GO-245A.

Description Product Number List Price

MicroVersaTrip Plus and PMPortable Power Pack TVPBP $75.00

POWER LEADER Power Supplies G0-104APower supply for furnishing 24Vdc control power for MicroVersaTripPlus and PM trip units. Two versions are available: a 1.5 ampereversion with AC and DC input voltages and a 0.8 ampere versioncapable of operating from 120/230Vac. Both power supplies haveinherent transient protection circuits.

System Requirements ProductDescription (price separately) Number List Price

1.5 ampere power supplyPrice one PLPS4G01 for

each line-up. 45 trip units Input power, 100VAand 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 $1250.00

POWER LEADER Voltage Conditioner G0-104AConditions and scales 120Vac to 1.76 Vac for use by the trip unit forvoltage sensing. Provides transient protection. Voltage conditionersrequire isolation PTs.

System Requirements ProductDescription (price separately) Number List Price

Supplies isolated busvoltage signal to One set of 3 voltage conditioners

MicroVersaTrip PM required for each voltage sensing $200.00

trip units. location. PTs also required. PLVC1G01 per set

Neutral Current Sensors1 GO-245BCircuit Breaker Neutral Sensor

Breaker Frame Sensor Rating Rating or Tap Product(Amperes) (Amperes) Settings (Amperes) Number List Price

200 200 TSVG302 $266.00

800 400 400/200 TSVG304A $266.00

400 600/3002 TSVG306A $266.00

800-1600 800 800/400 TSVG308A $266.00

1000 800/4002 TSVG808A $266.00

1600 1000 1000/500 TSVG810A $266.00

1600 1200/6002 TSVG812A $266.00

1600 1600/1000 TSVG816A $266.00

2000 2000 2000/1000 TSVG820A $266.00

1000 800/4002 TSVG808A $266.00

1000 1000/500 TSVG810A $266.00

1000 1200/6002 TSVG812A $266.00

3000 1000 1600/10002 TSVG816A $266.00

2000 2000/1200 TSVG820A $266.00

2500 2500/1800 TSVG825A $266.00

3000 3000/2400 TSVG830A $266.00

4000 4000 4000/3000 TSVG940A $266.00

1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.2For use with multiple source ground fault protection schemes. Rating does not match

MicroVersaTrip Plus or PM frame sensor.

Neutral Current Sensor

Rating Plug Removal Tool GO-135SProduct Number List Price

TRTOOL $12.00

ReferenceInstructions GEH-6492

Page 21: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-21Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

120 – SPE120R $1671.00 SPE120 $1838.00

240 – SPE240R $1869.00 SPE240 $2056.00

– 24 SPE024R $1869.00 SPE024 $2056.00

– 48 SPE048R $1869.00 SPE048 $2056.00

– 72 SPE072R $1869.00 SPE072 $2056.00

– 125 SPE125R $1869.00 SPE125 $2056.00

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

120 – SPRCS120R $286.00 SPRCS120 $315.00

240 – SPRCS240R $286.00 SPRCS240 $315.00

– 24 SPRCS024R $286.00 SPRCS024 $315.00

– 48 SPRCS048R $286.00 SPRCS048 $315.00

– 72 SPRCS072R $286.00 SPRCS072 $315.00

– 125 SPRCS125R $286.00 SPRCS125 $315.00

Electrical Operator

Remote Close Solenoid GO-245BThis accessory provides an electrically operated solenoid which, when energized, closesthe breaker. It is suitable for control interlock schemes in which manual closing capabilitywould not be convenient or desirable. The breaker is provided with a manual close button,which can be replaced by the Hidden "ON" Button accessory and/or sealed using the LimitedAccess Pushbutton Cover accessory. The remote close accessory is continuously rated andhas an anti-pump feature, which prevents a motor operated breaker from repeatedly closinginto a fault. Closing control voltage must be removed and re-applied for each breakerclosure.

Remote Close Solenoid

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Accessories—Stationary and Draw-out BreakersThe complete line of Power Break II breaker accessories may be either factory or fieldinstalled to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm withmechanical lockout, and the undervoltage release modules are drop-in from the front of thebreaker, interchangeable across all frames, and require no field internal wiring or breakerdisassembly. Auxiliary switch modules are available in groups of 4, 8 or 12, NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves removal of breakercover, installation of the switch module, routing of wiring and installation of the pre-wiredterminal block and re-installation of the cover. Auxiliary switches are also interchangeableacross all Power Break II breaker frames.

Electrical Operator GO-245BThe electrical operator mounts inside the front cover of the manually operated breaker. Thisaccessory can be added to any Power Break II breaker in the factory or the field to provideelectrical spring charging and charge indication. For remote closing, the remote close sole-noid must be priced and ordered separately. All breakers are prewired to dedicated second-ary terminals for easy field installation. When electrical operation is used, either a shunt tripor an undervoltage release must be ordered and priced separately.

Page 22: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-22 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Shunt Trip GO-245BThe shunt trip accessory is an electronic module, which provides remote control capabilityto open the circuit breaker. When activated, the shunt trip module sends a signal to the tripunit to open the breaker. This allows the trip unit to record, display, distinguish andcommunicate (in MicroVersaTrip PM trip units) that the opening event was initiated by theshunt trip device. The shunt trip is continuously rated and requires no cut-off switch. Whenenergized, the shunt trip supplies +24Vdc power to the trip unit to power the display.

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

– 12 SPST012R $301.00 SPST012 $328.00

24 24 SPST024R $301.00 SPST024 $328.00

48 48 SPST048R $301.00 SPST048 $328.00

120 125 SPST120R $301.00 SPST120 $328.00

208 – SPST208R $301.00 SPST208 $328.00

240 250 SPST240R $301.00 SPST240 $328.00

480 – SPST480R1 $301.00 SPST4801 $328.00

600 – SPST600R1 $301.00 SPST6001 $328.00

1Kit contains externally mounted transformer.

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

12 SPSTL012R $401.00 SPSTL012 $428.00

24 24 SPSTL024R $401.00 SPSTL024 $428.00

48 48 SPSTL048R $401.00 SPSTL048 $428.00

120 125 SPSTL120R $401.00 SPSTL120 $428.00

208 – SPSTL208R $401.00 SPSTL208 $428.00

240 250 SPSTL240R $401.00 SPSTL240 $428.00

480 – SPSTL480R1 $401.00 SPSTL480 $428.00

600 – SPSTL600R1 $401.00 SPSTL600 $428.00

1Kit contains externally mounted transformer.

Shunt Trip Module

Shunt Trip with Lockout Module GO-245BThe shunt trip with lockout is identical to the regular shunt trip, but when energized, it willalso prevent closure of an "open" breaker by mechanically blocking both manual and electri-cal closing. When energized, the closing springs will not discharge, the movable contactswill not move; the contacts are "kiss free."

Page 23: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-23Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Undervoltage Release Module GO-245BThe undervoltage release is an electronic module used to open the circuit breaker when themonitored voltage drops below 35-60% of its rated value, and prevents the breaker frombeing closed until the monitored voltage exceeds 80% of its rated value.

An undervoltage release trip operation is produced by the MicroVersaTrip Plus unit inresponse to a signal from the undervoltage release module. This allows the trip unit torecord, display, distinguish and communicate (in MicroVersaTrip PM trip units) that thebreaker opening event was due to undervoltage release. Operation of the undervoltagerelease module will prevent breaker contact closure, i.e. "kiss-free" operation. When ener-gized, the undervoltage release supplies +24 Vdc power to the trip unit to power the display.

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

24 – SPUVO24ACR $301.00 SPUV024AC $328.00

48 – SPUVO48ACR $301.00 SPUV048AC $328.00

120 – SPUV120ACR $301.00 SPUV120AC $328.00

208 – SPUV208ACR $301.00 SPUV208AC $328.00

240 – SPUV240ACR $301.00 SPUV240AC $328.00

480 – SPUV480ACR1 $301.00 SPUV480AC1 $328.00

600 – SPUV600ACR1 $301.00 SPUV600AC1 $328.00

– 24 SPUVO24DCR $301.00 SPUV024DC $328.00

– 48 SPUV048DCR $301.00 SPUV048DC $328.00

– 125 SPUV125DCR $301.00 SPUV125DC $328.00

– 250 SPUV250DCR $301.00 SPUV250DC $328.00

1Kit contains externally mounted transformer.

Undervoltage Release Module

Bell Alarm (Alarm Only) GO-245BThe bell alarm module is used to signal breaker "tripped" status to other accessories (e.g.,external alarm devices, indicating lights, relays, or logic circuits) for remote indication andinterlocking functions. The bell alarm response is configurable by means of rear-mountedDIP switches on the trip unit. The bell alarm can be made to operate in response to an over-current (including ground fault) or protective relay trip and/or a shunt trip operation, and/oroperation of the undervoltage release module. It is not actuated as a result of normalbreaker "ON/OFF" operation.

This module provides a visual, mechanical pop-out target, which protrudes through the faceof the circuit breaker door when it operates. The bell alarm may be reset manually bydepressing the mechanical target, or automatically by closing the breaker.

The bell alarm is provided with one SPDT switch with control power duty contacts as shownin the auxiliary switch accessories.

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

240 125-250 SPBAA240R $124.00 SPBAA240 $135.00

600 125-250 SPBAA600R1 $124.00 SPBAA600 $135.00

1600 Vac module not UL Listed.

Bell (Alarm Only)

Description Product Number List Price

Time Delay Module(0.1 to 1.0 second delay) SPUVTD $430.00

Time Delay Module for UVR GO-245BThe time delay module prevents nuisance tripping due to momentary loss of voltage.The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR.

Page 24: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-24 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Bell Alarm With Lockout GO-245BThe bell alarm with lockout module combines both the bell alarm and a manual lockout func-tion. The bell alarm switch operates identically to the standard bell alarm module, exceptthat the mechanical pop-out target must be manually reset before the breaker can be closed.

Operation of the bell alarm with lockout module can be independently set by means of set-ting the DIP switches at the rear of the trip unit. Current rating of the single SPDT switch isidentical to the auxiliary switch accessories.

Ratings Ratings Field Installable Factory InstalledVac Vdc Product Number List Price Product Number List Price

240 125-250 SPBAL240R $124.00 SPBAL240 $135.00

600 125-250 SPBAL600R1 $124.00 SPBAL600 $135.00

1600 Vac module not UL Listed.

Bell Alarm with Mechanical Reset Lockout

Auxiliary SwitchAn auxiliary switch signals the circuit breaker’s primary contact position (i.e., OPEN orCLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables theuser to provide remote indication, interlocking or control operations as a function of breakerprimary contact position. The auxiliary switch operation is independent of the method bywhich the breaker is opened or closed. The auxiliary switch does not distinguish between a"tripped" or "open" condition. The auxiliary switch contacts follow the main breaker contactson opening and precede them on closing.

Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for controlpower duty ac/dc ratings. When ordered for field installation, an auxiliary switch modulecomes pre-wired to its own terminal board, which mounts with one screw to the left of thebreaker. A special accessory, available for draw out breakers, comes pre-wired to thebreaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125 Vdcand 1/4A at 250 Vdc.

Auxiliary Switches for Stationary Breakers GO-245BNo. of SPDT

Ratings Ratings Switch Elements Field Installable Factory InstalledVac Vdc (Contacts) Product Number List Price Product Number List Price

240 125-250 4 SPAS240AB4R $268.00 SPAS240AB4 $293.00

240 125-250 8 SPAS240AB8R $564.00 SPAS240AB8 $616.00

240 125-250 12 SPAS240AB12R $651.00 SPAS240AB12 $710.00

600 125-250 4 SPAS600AB4R1 $268.00 SPAS600AB41 $293.00

600 125-250 8 SPAS600AB8R1 $564.00 SPAS600AB81 $616.00

1600 Vac module not UL Listed.

Auxiliary Switch with Pre-wiredSecondary Terminals for Stationary Breaker

Auxiliary Switch with Pre-wiredSecondary Terminals for Draw-out Breaker

Auxiliary Switches for Draw-out Breakers GO-245BNo. of SPDT

Ratings Ratings Switch Elements Field Installable Factory InstalledVac Vdc (Contacts) Product Number List Price Product Number List Price

240 125-250 4 SPAS240AB4DR $551.00 SPAS240AB4D $576.00

240 125-250 8 SPAS240AB8DR $847.00 SPAS240AB8D $899.00

240 125-250 12 SPAS240AB12DR $934.00 SPAS240AB12D $993.00

600 125-250 4 SPAS600AB4DR1 $551.00 SPAS600AB4D1 $576.00

600 125-250 8 SPAS600AB8DR1 $847.00 SPAS600AB8D1 $899.00

1600 Vac module not UL Listed.

Page 25: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-25Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Mechanical Operations Counter GO-245BThe mechanical operations counter is mounted behind the front cover of the breaker. It isviewable through a rectangular knockout window opening in the breaker cover. It is a five-digit, non-resettable counter, which is actuated each time the breaker is opened byany means.

Field Installed Factory InstalledProduct Number List Price Product Number List Price

SPCOUNTERR $100.00 SPCOUNTER $125.00

Hidden "ON" Button GO-245BThe hidden "ON" button is assembled to the mechanism behind an unlabeled, falsepushbutton. Manual closing of the breaker can only be performed by means of a smalldiameter rod. This accessory is used to limit access to the manual "ON" control to authorizedpersonnel.

Field Installed Factory InstalledProduct Number List Price Product Number List Price

SPPBNONR $64.00 SPPBNON $64.00

Replacement Trip Unit Access Doors GO-148GDescription Product Number List Price

MicroVersaTrip Plus and PM Trip Units 10054335P1 $20.00

Power Plus Trip Units 10054335P2 $16.00

Limited Access Pushbutton Cover GO-245BThis accessory limits access to "ON/OFF" control of a breaker to authorized personnel. Thepushbutton cover accessory consists of transparent hinged covers that can be individuallysealed to the limited access assembly. Both the "ON" and "OFF" buttons can be pilot drilled toallow use of a 1/8" rod to operate either one or both pushbuttons.

Field Installed Factory InstalledProduct Number List Price Product Number List Price

SPPBCOVERR $80.00 SPPBCOVER $90.00

Mechanical Operations Counter

Breaker with limited access pushbuttoncover assembly installed

Activating the breaker closing mechanismthrough the hole in the Hidden “ON” Button

probe
Page Update September
Page 26: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-26 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersStationary and Draw-out Breaker AccessoriesAll devices UL Listed for factory or field installation except where noted.

Key Interlock ProvisionsThe key interlock provision enables the user to mount a one- to four-cylinder, narrow-faced,Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This accessoryprovides mounting for key interlocks that are furnished by the customer. The key interlockprovision works in conjunction with the padlock provision. The key interlock extends a leverthrough the padlock hasp when the key is turned to the key removal or bolt extended posi-tion. Additionally, the accessory provides a hasp for mounting three padlocks with 1/4" to 3/8"diameter shanks.

Padlock Provisions (Standard)Padlocking provisions are standard on all Power Break II circuit breakers. When the breakeris in the open position, and the padlock hasp is raised at least 1/4", the breaker cannot beclosed mechanically or electrically. The hasp accepts up to three padlocks with 1/4" to 3/8"diameter shanks.

Walking Beam Interlocks—Stationary Breakers Only GO-245BWalking beam interlocks are mechanical devices used to prevent two adjacent circuit break-ers from both being in the "ON" or closed position at the same time. However, both breakerscan be in the "OFF" or open position.

Door Interlock GO-245BThe door interlock provides interlocking of the circuit breaker compartment’s hinged door sothat the breaker must be in the "OFF" position before the door can be opened. The door inter-lock is defeatable with a small tool to allow authorized access.

Circuit BreakerEnvelope Size (Amperes) Product Number List Price

800, 1600 and 2000 SPWB20 $1228.00

3000 SPWB30 $1228.00

4000 SPWB40 $1228.00

Product Numbers, Key Interlock Provisions GO-245BCircuit Breaker Number of Field Installed Factory Installed

Envelope Size (Amps) Key Locks Product Number List Price Product Number List Price

All 1 to 4 SPK4R $355.00 SPK4 $426.00

Key Interlock Reference TableKirk Key Lock Superior

Product Number Number of Locks Product Number Product Number

SPK4 1 KFN000011 S105827YSPK4 2 KFN000021 S105828YSPK4 3 KFN000031 S105829YSPK4 4 KFN000041 S105827-4Y

1Final digit may be 0, 1, 2 or 3 depending on number of key removal positions.

Field Installed Factory InstalledProduct Number List Price Product Number List Price

SPDILR $173.00 SPDIL $208.00

Key Interlock Kit (lock not included)

Door Interlock

Page 27: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-27Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersStationary Breaker Mounting KitsAll devices UL Listed for factory or field installation except where noted.

Lug Adapter Kits GO-245BKits pre-mount to bus structure allowing cabling or bussing to be completed prior to breakermounting. Accepts either lugs or crimp-type connector terminals. Kit includes adapter andhardware for either a three-pole line-side, or a three-pole load-side connection. (Lugs notincluded).

Circuit Breaker Max Rating Product Lug Max. Cables Wire RangeEnvelope Size (Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI List Price

400 TPLUG106 1 1 (2) #2 2-600 $18.50

600 TPLUG206 1 2 (2) #2 2-600 $27.50800

800 TPLUG308 1 3 (3) 300-750 $32.00

800 TPLUG1084 1 3 3/0-800 $23.00

1600800 TPLUG1084 1 6 3/0-800 $23.00

1600 TPLUG408 1 4 500-800 $39.00

2000 TPLUG1084 1 6 3/0-800 $23.00

2000800 TSLUG08 9 3 3/0-800 $274.00

1200 TSLUG12 12 4 3/0-800 $296.00

1600 TSLUG16 15 5 3/0-800 $345.00

2000 TSLUG20 18 6 3/0-800 $383.00

3000 2500 TSLUG25 21 7 3/0-800 $418.00

3000 TSLUG30 27 9 3/0-800 $630.00

4000 4000 TSLUG40 27 9 3/0-800 $1045.00

4For use with adapter kit only. See table above.

Frame Product Suitable forRating (Amperes) Number use with up to: List Price

3 TPLUG108 Lugs or800 TPLUGA08 3 crimp Lugs1 per pole $78.50

6 TPLUG108 lugs or1600 TPLUGA162 6 crimp Lugs1 per pole $389.00

6 TPLUG108 Lugs or2000 SPLUGA203 6 crimp Lugs1 per pole $487.00

1Anderson No. VCEL-075-12H1 or equivalent2T-Studs - TP16FCA - included with adapter3T-Studs - SP20FCA - included with adapter

Lug Kits GO-245BKits accept Cu/AI wire and are suitable for direct mounting to the breaker. When orderingType TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs for theline side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs.

When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be Qty 1-TSLUG25. T-Studs would also be required.

2000 Ampere Power Break II breaker with SPLUGA20 lug adapter kit and 18 lugs

(TPLUG108)

Type TPLUG206

Type TPLUG408

Type TPLUG308

Type TSLUG20

probe
Page Update September
Page 28: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-28 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersStationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted EnclosuresAll devices UL Listed for factory or field installation except where noted.

T-StudsT-studs mount directly to the breaker, and can be rotated for either vertical or horizontal busconnection. 4000 ampere T-studs are for vertical bus bars only. Product number includes onestud. Both copper and aluminum T-studs are tin-plated.

Stationary Breakers General Purpose, Wall Mounted EnclosuresGeneral purpose, NEMA 1 enclosures are available for Power Break II breakers withneutrals for 800, 1600 and 2000 amperes. These units are UL Listed for service entranceuse for single-phase three-wire, three-phase three-wire, or three-phase four-wire powersystems through 600 Vac. Enclosures are provided with breaker mounting studs and lugs.Enclosures, breakers and neutrals are ordered and shipped separately, unassembled.These units are suitable for use in 65 kA (max.) rms symmetrical systems.

Floor mounted enclosures are available. For Ordering and Pricing, see Engineered ProductsCatalog, Section 3: Individually Mounted Circuit Breakers.

T-Studs—Front Connected Breaker GO-245BCircuit Breaker Max. Rating

Frame Size (Amperes) (Amperes) Product Number List Price

800 800 SP08FCA1 $36.00

800 800 SP08FCC2 $36.00

2000 800-2000 SP20FCA1 $49.00

2000 800-2000 SP20FCC2 $49.00

2500 2000 SPS20FCA1 $48.75

2500 2500 SPS25FCC2 $51.50

3000 3000 SPS30FCC2 $181.50

4000 4000 SPS40FCC2 $240.50

4000 4000 SPS40LFCC2,3 $395.00

T-Studs—Back Connected Breaker GO-245BCircuit Breaker Max. Rating

Frame Size (Amperes) (Amperes) Product Number List Price

2500 2000 SPS20BCA1,4 $48.75

2500 2500 SPS25BCC2,4 $51.50

3000 3000 2,5 $181.50

1Aluminum2Copper3Extra long stud. Alternate with SPS40FCC for ease of installation.4Six T-studs at no charge when ordered with breaker5Supplied with integral T-stud

Wall Enclosure and Field Installed NeutralEnclosure7 Field installed

Circuit Breaker Current Sensor Product Number List Price Neutral List PriceEnvelope Size (Amperes) Rating (Amperes) (include Lugs) GO-134C Product Number GO-149

800 200-800 SPB08W $2569.00 TNT800 $384.00

1600 1000-1600 SPB16W $3667.00 TNT1600 $437.00

2000 2000 SPB20W $4309.00 TNT2000 $537.00

7For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault protection, appropriate neutral CT mustbe ordered with circuit breaker from page 5-20.

Trimplate GO-245BFactory Installed Field InstallableProduct Number Product Number List Price

SPTRIMPLATE SPTRIMPLATER $64.00

2000A Breaker with "T" Studs Mounted

Page 29: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-29Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break II Circuit BreakersDraw-out Breakers and Accessories

Features—Draw-outs through 4000 amperes are UL Listed, 100% rated—Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500,

3000, 4000—5 inch pole centers—Screw racking mechanism provides positive racking motion—Self aligning primary and secondary disconnects—Four position draw-out—engaged, test, disengaged, fully withdrawn—

simplifies system testing and inspection—Breaker position indicator clearly shows breaker position—Provisions for padlocking breaker in test or disengaged position—Mechanical interlock logic prevents movement of a closed breaker—Suitable for reverse feeding

DescriptionThe draw-out assembly consists of a substructure housing unit designed as a compact self-supporting unit and a draw-out breaker which must be ordered separately. The substructurecontains mounting holes, self-supporting male plugs and extendable rails, and can beordered separately for installation in your switchboard or enclosure.

The Power Break II draw-out breaker is a self-contained, heavy-duty assembly designed tooffer simplified breaker inspection without de-energizing the main bus structure.

The draw-out breaker comes complete with racking mechanism drive, wheels, primary andsecondary disconnects and cooperating interlock systems.

Accessories such as dead-front shutters, by-pass switches (position switches), and padlockdevices are available and field installable.

OEM Substructures GO-245BSubstructures are available for both standard and Hi-Break Power Break II breakers. Holesare provided for bolting on a shelf or supports. Holes are also provided in the primary stabsfor bolting to busbars or terminal lugs. Substructure secondary disconnects are ordered andpriced separately. Order Hi-Break substructures for use with Power Break II switches.

Frame Rating Standard Break Hi-Break(Amperes) Product Number List Price Product Number List Price

800 SPSDOS08 $671.00 SPHDOS08 $724.00

1600 SPSDOS16 $1300.00 SPHDOS16 $1403.00

2000 SPSDOS20 $1892.00 SPHDOS20 $2040.00

2500 SPSDOS25 $2048.00 SPHDOS25 $2207.00

3000 SPSDOS30 $2739.00 SPHDOS30 $2951.00

4000 SPSDOS40 $6916.00 SPHDOS40 $7455.00

Location Product Number List Price

Substructure SPDOSD36S $283.00

Breaker1 SPDOSD36B $283.00

1Order for replacement only. Included and factory wired with draw-out breaker.

Draw-out Breaker in Substructure

1600-ampere substructure for standard break breaker

Secondary Disconnect for Draw-out Breakers GO-245BControl wiring is connected through draw-out secondary disconnects in the "TEST" and"CONNECTED" positions only. Up to 72 control circuits are possible through 36 position plug-style secondary disconnect blocks factory mounted to each side of draw-out breakers.One substructure disconnect (SPDOSD36S) must be ordered for each breaker when acces-sories or communications are used. When auxiliary switches are used along with any otherelectrical accessory or communications, two disconnects must be ordered.

probe
Page Update September
Page 30: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-30 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break II Circuit BreakersDraw-out Breakers and AccessoriesAll devices UL Listed for factory or field installation except where noted.

Racking Tool GO-245BThe racking tool is a drive wrench with a square 1/2" socket thatengages the racking mechanism of the draw-out breaker. One rack-ing tool is supplied with every five draw-out breakers at no charge.

Racking Padlock Provision GO-245BThe racking padlock provides a means for the user to prevent rackingtool engagement, thereby preventing movement of the breakerbetween the DISCONNECTED, TEST and CONNECTED positions.

Lifting Bar GO-245BThe lifting bar provides a means of safely lifting a draw-out circuitbreaker. A chain hook can be attached to the central hole in the lift-ing bar or a 1" diameter black iron pipe can be put through the twoholes above the hooks, allowing two people to carry the breakerbelow waist level from either side of the breaker.

By-Pass Switch GO-245B

Provides positive indication that the draw-out breaker or switchprimary contact fingers are fully connected to the main bus in thesubstructure. Switch contacts change states only after the primaryfingers are fully connected when the breaker is being moved fromthe DISCONNECTED position through the TEST position and into theCONNECTED position.

May be used to provide control circuit continuity or downstreamsignaling that the draw-out breaker is connected in addition to thevisual position indicator on the draw-out substructure. The By-passswitch accessory does not indicate either the TEST or DISCON-NECTED position. The switch assembly mounts on the stationaryframe and the actuator mounts to the carriage. Switch contacts arerated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.

Shutter Kit GO-245BThis field installable kit provides shutters used to prevent uninten-tional contact with potentially live primary disconnect stabs when abreaker is racked out of an energized switchboard compartment.

Rail Kit GO-245BThis field installable rail kit may be used to shorten the two standardOEM substructure rails by 3-1/2 inches.

Mechanical Interlocks GO-245BMechanical interlocks provide the same function as the walkingbeam accessory for stationary breakers, except they are used withtwo draw-out breakers: mounted on common compartment center-line, in either the same vertical section or adjacent vertical sections.

Frame Rating Product Number List Price

All TDOPC $46.00

One lifting bar is supplied with every five draw-out breakers atno charge.

Frame Rating Product Number List Price

All TDOLB $104.00

Number ofSwitch Elements Product Number List Price

2 NO/2 NC TDOBP2L $177.00

4 NO/4 NC TDOBP4L $256.00

6 NO/6 NC TDOBP6L $336.00

Product Number List Price

SPRAILS $310.00

Frame Rating Product Number List Price

800-2000A SPDSS20 $501.00

3000A SPDSS30 $501.00

4000A SPDSS40 $501.00

Envelope Size Product Number List Price

800-2000 SPDOWB20 $1310.00

2500-4000 SPDOWB40 $1310.00

Frame Rating Product Number List Price

All TDORT $70.00

Position Switch GO-245BProvides positive indication when the draw-out breaker or switchprimary contact fingers have been fully withdrawn from the main busconnections. Switch contacts change state only after the primaryfingers are fully disconnected when the breaker is being moved fromthe CONNECTED position through the TEST position and into theDISCONNECTED position.

May be used as part of a safety interlocking system in addition tothe visual indicator on the draw-out substructure. The PositionSwitch accessory does not indicate either the TEST or CONNECTEDposition. The switch assembly mounts on the stationary frame andthe actuator mounts to the carriage. Switch contacts are rated at10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.

Number of Switch Elements Product Number List Price

2 NO/2 NC SDOPS2L $177.00

4 NO/4 NC SDOPS4L $256.00

6 NO/6 NC SDOPS6L $336.00

Page 31: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-31Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersRatings and Trip Characteristics

Power Break I Circuit Breakers for DC Applications and Replacement AC NeedsThe GE line of Power Break I insulated case circuit breakers offers the rugged, reliable sys-tem protection critical for heavy-duty DC power applications and for the replacement, add-on and hole-filler needs of existing AC applications. Power Break circuit breakers are ratedup to 200,000 amperes rms symmetrical interrupting capacity without fuses or current lim-iters. The Power Break design consists of five physical envelope sizes, providing protectionfrom 100 to 4000 amperes.

Power Break I is a versatile breaker, designed for a wide variety of applications with featuresincluding temperature insensitive trip units, push-to-open and close buttons, maximum five-cycle close time, UL Listed, field-installable rating plugs to change a breaker’s rating, UL Listed,(file E11592), field-installable accessories, easy to operate, rotary, charge storage handle.

A full line of selective tripping characteristics can be used to provide overcurrent protectionfrom overloads, short circuits and ground faults. Additionally, local trip indicators (targets)visually signal long-time, short-time, instantaneous and ground fault trips.

Power Break I circuit breakers with enhanced MicroVersaTrip solid state trip units andMagneTrip dual-magnetic trip units offer application flexibility for ac as well as dc systems.Power Break with MagneTrip is rated up to 700 Vdc and 750 Vac.

MagneTrip is 100 percent rated for ac or dc power distribution systems. MagneTrip alsooffers interchangeable trips for 3000 ampere envelope size.

A full line of Power Break draw-out substructures, interlocks, accessories, internal electricaloperators, connectors, a portable digital test kit, and a portable battery power pack is available.

MicroVersaTrip trip units for Power Break insulated case circuit breakers digitally measurethe true RMS (heating) value of the current, regardless of the wave shape, by RMS digitalsensing of sinusoidal and non-sinusoidal currents.

Features—High-dielectric strength, glass reinforced insulating case for increased durability

and safety of operation.—Interphase barrier partitions mesh with breaker cover to completely isolate each

pole for high transient voltage withstandability.—Green (OFF), Red (ON), indicators display the position of the breaker contacts.—Extra heavy-duty, low torque-handle mechanism for simple, stored energy charging.—Easy quick-make, quick-break close/open operation.—Complete line of accessories, UL-Listed for field installation.—Short circuit ratings through 200,000 Amperes.—RMS digital sensing of sinusoidal and non-sinusoidal currents by the solid-state

trip device.—Field-installable, interchangeable rating plus.—Two trip unit options:

—MicroVersaTrip Plus trip units for overcurrent protection.—MicroVersaTrip PM trip units for metering, protective relays, and

GE POWER LEADER communications.

800A Envelope

2000A Envelope

3000A Envelope

4000A Envelope

Page 32: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-32 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit BreakersDraw-Out Breakers

TC3030TT

Breaker rotated for inspection

Features—Draw-Outs through 4000 amperes are UL Listed, 100% rated—Modular design for simplified installation—6 basic sizes—800,

1600, 2000, 2500, 3000 and 4000 amperes—5-inch pole centers—Screw racking mechanism provides positive racking motion—Self aligning primary and secondary disconnects—Four position draw-out—engaged, test, disengaged, fully

withdrawn—simplifies system testing and inspection—Breaker position indicator clearly shows breaker position—Provisions for padlocking breaker in test or disengaged position—Mechanical interlock logic prevents movement of a closed

breaker—Suitable for reverse feeding

DescriptionThe draw-out assembly consists of a substructure housing unitdesigned as a compact self supporting unit and a draw-out breakerwhich must be ordered separately. The substructure containsmounting holes, self supporting male plugs and secondary discon-nect strips, extendable rails, and can be ordered separately forinstallation in your switchboard or enclosure.

The Power Break draw-out breaker is a self-contained, heavy dutyassembly designed to offer simplified breaker inspection without de-energizing the main bus structure.

The draw-out breaker comes complete with racking mechanismdrive, wheels, primary and secondary disconnects and cooperatinginterlock systems.

Accessories such as dead-front shutters, position switches, andpadlock devices are available and field installable.

NOTE: These draw-out breakers are not suitable for use in old style(TPD, THD) substructures.

Page 33: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-33Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersHow To Order

How To OrderPower Break frames are factory configured either forMicroVersaTrip Plus trip units only (frame suffix “T” or “TT”) or forMicroVersaTrip PM trip units, (frame suffix “TR” or “TTR”). If provi-sion for 24 Vdc trip unit control power for MicroVersaTrip Plus tripunits is required, or if provision for future upgrade to MicroVersaTripPM, is desired, select frames with “TR” or “TTR” suffixes from page5-40. For draw-out frames select the appropriate substructuremounted trip unit secondary disconnect from page 5-51.

1. Determine the required breaker frame, IC/short-time rating, andload requirements. Select appropriate stationary or draw-outbreaker frame product number and list price on page 5-40.

2. Select and price the appropriate frame modification from page 5-42.

3. Select the basic MicroVersaTrip trip unit to match the frameampere rating from page 5-43.

4. Select and price the trip unit suffix from page 5-43 and 5-44 tomatch the required trip functions. Refer to page 5-37 for trip unitcharacteristics.

5. Select and price the required rating plug from page 5-45. The sen-sor rating of the frame must match the sensor rating of the plug.

6. Select and price lugs and accessories from pages 5-51 through 5-52. Draw-out substructure should be priced from page 5-39 ifrequired.

7. When ordering, specify separate product numbers as follows. Thetrip unit will be installed in the frame. Rating plugs will be shippedseparately. Specify “Assembled” for installed accessories.

—Frame including modifications suffix—Trip unit including function suffix—Rating plug—Lugs (if required)—Accessories (if required)

Pricing Example GO-145C1600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor,600 ampere frame, 100kA, 480 Vac IC rating, 1000 ampere sensor, 600ampere rating plug, 100% rated draw-out construction, 120 Vac shunttrip assembled, trip unit functions to include long-time (L), short-time(S), high range instantaneous (H), 120 Vac electrical (motor) opera-tion (E1), trip targets, draw-out substructure.

Power Break I Rating Plug (X) and Current Sensor (S) Rating

Envelope SizeFrame Max.

Rating (Amperes)Sensor Rating (Amperes) (S) Rating Plug Amperes (X)

200 100, 150, 200

400 150, 200, 225, 250, 300, 400

800 300, 400, 500, 600, 700, 800

1000 400, 600, 800, 1000

1600 600, 800, 1000, 1200, 1600

2000 2000 2000 800, 1000, 1200, 1600, 2000

1000 400, 600, 800, 1000

2000 800, 1000, 1200, 1600, 2000

2500 1600, 2000, 2500

3000 3000 2000, 2500, 3000

4000 4000 4000 1600, 2000, 2500, 3000, 4000

S = Sensor ampere rating

X = Rating Plug amperes

800

1600

3000

800

1600

2500

Description Product Number List Price

Frame and Suffix ($8671 + $1656) THC1610TTHE1 $27890.00

Trip Unit and Suffix Adder C210LSH $2700.00

Rating Plug TR10B600 $178.00

Shunt Trip (Assembled) TPST12S No Charge1

Draw-out Substructure THDOS16E $3230.001

Secondary Disconnects (2) TDOSD6S $320.001

1GO-145A.

THP 16 TT E1C10

Circuit Breaker

Current Interrupting Capacity

TP = Standard BreakTHP = Hi-BreakTUP = Special Hi-BreakTC = Standard Break Draw-outTHC = Hi-Break Draw-out

Auxiliary Breaker Frame Functions

Configured for

MicroVersaTrip PM trip unit

FC = Front ConnectedE1-7 = Electrical OperationC = Concealed "ON" ButtonH = High Range InstantaneousZ = Zone Selective Interlocking

R

Trip Type and Rating

TT = MicroVersaTrip™ Plus or PMProgrammer

Breaker Frame Rating

8 = 800 25 = 250016 = 1600 30 = 300020 = 2000 40 = 4000

MagneTrip™

MM

Sensor Current Rating (Amperes)

Related to breaker sensor rating(MicroVersaTrip) or continuous current rating (MagneTrip Trip Unit).

®

1

2

2

2 = 200A 16 = 1600A4 = 400A 20 = 2000A 25 = 2500A8 = 800A 30 = 3000A10 = 1000A 40 = 4000A

Product Number Construction

1Stationary breakers only.2MagneTrip only.Note: This information is provided for use interpreting product number.

It cannot be used to build product numbers.

Page 34: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-34 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break Molded Case Switch Withstand RatingsSuitable on 200,000 ms Short Circuit Withstand Rating

Sym Ampere Fault Circuit when Protected by Power Breakwhen protected by Class L Breaker with MicroVersaTrip Plus or

Short-Time Fuses as Follows: MicroversaTrip PM Trip UnitRating, rms

Switch Continuous Sym Amperes at Line Size Load Side BreakerFrame Size Current Rating 600 Vac Max., Max. Fuse Max. Fuse Frame Size(Amperes) (Amperes) 500 ms Max. Ampere Rating Ampere Rating (Amperes) 480 Vac 600 Vac

800 800 25,000 2000 800 800 100,000 65,0001600 1600 30,000 2500 1600 2000 100,000 65,0002000 2000 30,000 2500 2000 2000 100,000 65,0002500 2000 42,000 2500 2500 4000 100,000 65,0002500 2500 42,000 2500 2500 4000 100,000 65,0003000 3000 42,000 40005 30005 4000 100,000 65,0004000 4000 42,000 40005 40005 4000 100,000 65,000

5Use only Hi-Break breaker with 4000 ampere fuses.

Power Break I Circuit BreakersRatings and Trip Characteristics

Interrupting CapacityEnvelope Size

Type of Construction 800A 1600A 2000A 3000A 4000A

Max. Short time Rating, kA1 25 30 30 42 42240Vac 65 85 85 100 100

Standard Break 480Vac 65 65 65 100 100600Vac 42 50 50 85 85250Vdc2,3 – 22 – 42 42240Vac 100 125 125 200 200480Vac 100 100 100 150 150

Hi-Break600Vac 65 65 65 100 100250Vdc2,3 – 35 – 85 85500Vdc2 – – – 65 65600Vdc2 – – – 65 65

Special Hi-Break4 750Vac – – – 35 35700Vdc – – – 65 65

1With "H" option MicroVersaTrip trip unit only. 600 Vac, 50/60 Hertz, 500 ms. Not available on 4000A stationary breaker.

2DC ratings apply only to Power Break breaker with MagneTrip trip unit.31600 A frame MagneTrip (TPMM, THPMM, TCMM, and THCM) also rated 30kA, 500 Vdc, with poles in

series for ungrounded battery applications.4Ratings apply only to Power Break breaker with MagneTrip trip unit Type TUPMM. Not UL Listed.

Dimensions and WeightsComplete dimensions and weight information can be found in the Power Break I ApplicationGuide, GET-6211.

The interruption ratings and voltages shown in the table are maximum ratings. A circuitbreaker of the type given in the left-hand column may be applied at the given circuit voltagein any electrical distribution system where the available fault current at the load terminalsof the breaker does not exceed the value in the table. That circuit breaker type may also beapplied at intermediate values of circuit voltage provided the available fault current at theload terminals of the breaker does not exceed the value in the table for the higher value ofvoltage.

Page 35: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-35Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersRatings and Trip Characteristics

MagneTrip Trip Unit CharacteristicsLong Short Time Adjustable Fixed

Current Ampere Setting Time Short-time Instantaneous InstantaneousFrame Ratings (Multiple of Delay Pickup (Multiple Delay Pickup (Multiple OverrideSize (Amperes) current rating) (Sec.) 1 of current rating) (Sec.) 2 of current rating) (Amperes)

200, 400, 600 0.7-1.0 4 3-10 0.04 3-10 None

1600 800, 1000 0.7-1.0 4 3-10 0.04 3-10 None1200 0.7-1.0 4 3-8.2 0.04 3-8.2 None1600 0.7-1.0 4 3-7.5 0.04 3-7.5 None

600, 800, 1000 0.7-1.0 4 3-10 0.07 3-10 42,0001200 0.7-1.0 4 3-8.2 0.07 3-8.2 42,000

2500 1600 0.7-1.0 4 3-7.5 0.07 3-7.5 42,0002000 0.7-1.0 4 3-6.8 0.07 3-6.8 42,0002500 0.7-1.0 4 2.3-5.5 0.07 2.3-5.5 42,000

3000 3000 0.7-1.0 4 3-5.3 0.07 3-5.3 42,0004000 4000 0.7-1.0 4 2.2-4 0.07 2.2-4 42,000

1Time delay shown at 600 percent of breaker current rating at lower limit to trip time curve.2Time delay shown at 10X breaker current rating at lower limit of time curve.Complete dimension and weight information can be found in the Power Break I application guide, GET-6211.

Page 36: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-36 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Features exclusive to MicroVersaTrip PM Trip UnitsCommunications

—All information can be viewed on the LCD display orcommunicated over a POWER LEADER PowerManagement System network.

Demand/peak demand—The trip unit can display a rolling average of power demand

and peak power demand at user-selected intervals from 5 to60 minutes

Local and remote metering—Amperes, volts, frequency—Real power, total power—Accumulated energy

Protective relays include—Current and voltage unbalance—Overvoltage—Undervoltage—Power reversal—Power reversal direction setup

Two Choices Of Advanced, Digital Solid-State Trip UnitsEnhanced MicroVersaTrip Plus and MicroVersaTrip PM tripunits give you two ways to monitor and control the Power Break Ibreaker with unprecedented ease. Through the simple keypad, thetrip unit lets you program and display a variety of functions includingtripping characteristics, remote communications, status informationand protective relaying, and allows integration with GE POWERLEADER Power Management Systems. The trip unit display alsoallows viewing of many standard metering parameters as well aspickup alarms, trip target indications and fault status information.

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM trip unitsuse GE’s proven technique of measuring true rms currents (andvoltages for MicroVersaTrip PM trip units) of both sinusoidal andharmonically distorted waveforms. The frequent sampling (64 timesper cycle) allows precise calculations of true rms current. The sam-pling rate allows waveform measurements up to the 31st harmonicto achieve accuracies of 99%. GE’s true rms sensing avoids potentialunderprotection or overprotection problems associated with peak-sensing tripping systems.

The enhanced trip unit design includes a wide range of functionsand adds many new features:

Trip operations counter—The number of long-time, short-time, instantaneous and ground

fault trips are individually counted and displayed.

Trip information—On overcurrent faults, the trip unit displays fault pickup, the type

of fault, the magnitude of the fault current and the phase thefault occurred on.

New display—Ergonomic, 5-button keypad—New targets with international symbols—High-resolution LCD display for local 3-phase ammetering—New status and setup displays for greater ease of use—True rms sensing for accurate response to high harmonic

content waveforms for Long-Time, Short-Time, and GroundFault protection.

—50/60 Hz operation.—Interchangeable, UL Listed trip units and rating plugs with test

set jack for TVRMS2 test set.—EMI immunity per ANSI C37.90.

Enhanced MicroVersaTrip Plus and MicroVersaTrip PM TripUnits have been specifically designed to integrate with the

extensive capabilities offered by Power Break circuit breakers.

Power Break I Circuit BreakersTrip Unit Features

Page 37: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-37Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit Breakers with EnhancedMicroVersaTrip Plus and MicroVersaTrip PM Trip UnitsTechnical DataTrip Unit Characteristics

Enhanced MicroVersaTrip Plus and PM Trip Unit Characteristics

Trip Unit Characteristics (continued)

Pick-Up (Multiple of Sensor Ampere Rating)

Delay with I 2 T Seconds

Delay 3 without I 2 T Seconds

8001.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01 .10, .21, .35

16001.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01 .10, .21, .35

20001.5 thru 10.0 in 0.5 increments

1.5 thru 15.0 in 0.5 increments

0.20 thru 0.60 in increments of 0.01 .10, .21, .35

30001.5 thru 10.0 in 0.5 increments

1.5 thru 13.0 in 0.5 increments

0.20 thru 0.37 in increments of 0.01 .10, .21, .35

40001.5 thru 9.0 in

0.5 increments1.5 thru 9.0 in

0.5 increments0.20 thru 0.30 in

increments of 0.01 .10, .21, .35

Ground Fault

Envelope Size

Adjustable Instantaneous Pick-Up without ST (Multiple of

Rating Plug Amperes) (X)

Adjustable Instantaneous Pick-Up

with ST (Multiple of Rating Plug Amperes) (X)

High Range Instantaneous

(Multiple of Frame Short-Time Rating) (H)

3Time delay shown at lower limit of each band. Ground fault pick-up not to exceed 1200 amperes.X = Rating plug amperes

H = Short-time rating

1.0

.37 at 200% of pick-up at lower limit

of band

C = Long-time current setting (pick-up)

S = Sensor ampere rating

2Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%.

1Time delay shown at 600% of current setting at lower limit of band.

Current Setting (C) (Pick-Up) Multiple of Rating Plug Amperes (X) Delay1 (Seconds)

Pick-Up (Multiple of Current Setting) (C) Delay (Seconds)

800 800 200, 400, 800 2.4, 4.9, 9.8, 20

1600 1600 1000, 1600 2.4, 4.9, 9.8, 20

2000 2000 2000 2.4, 4.9, 9.8, 20

2500 1000, 2000, 2500

3000 3000

4000 4000 4000 2.4, 4.9, 9.8, 20

I2T in 1

0.40

I2T out 2

.10, .21, .35

0.5 thru 1.0 in increments of 0.05

1.5 thru 9.0 in increments of 0.05

3000 2.4, 4.9, 9.8, 20

Long-Time Short-Time

Envelope SizeFrame Max.

Ampere Rating

Sensor Rating (Amperes) (S)

M (Metering) P (Relaying) PM (Metering & Relaying)

Communications —POWER LEADER Communications Bus Link STD STD STD

Amperes (A, kA)5 Selectable Phase Current ±2.5% STD

STD STD

Voltage (V) L-L or L-N Volts ±1.5%

Energy (kWh, MWh, GWh) Total Energy Usage on Brkr ±4%

Real Power (kW/MW) L-L or L-N Power ±4%

Total Power (kVA/MVA) L-L or L-N Power ±4%

Frequency (Hz) Circuit Frequency ± 1Hz

Demand & Peak Demand (kW)

Under Voltage Trip—Adjustable pickup 50-90%—Adjustable delay, 1-15 seconds OFF

Over Voltage Trip—Adjustable pickup, 110-150%—Adjustable delay, 1-15 seconds OFF

Voltage Unbalance—Adjustable pickup, 10-50%—Adjustable delay, 1-15 seconds OFF

Current Unbalance—Adjustable pickup, 10-50%—Adjustable delay, 1-15 seconds OFF

Power Reversal—Adjustable pickup, 10-990 kW—Adjustable delay, 1-15 seconds OFF

Function Description

Trip Unit Suffix

MicroVersaTrip PM Trip Unit Characteristics4

4MicroVersaTrip PM functions require 24 Vdc control power.5Ampere reading also standard on MicroVersaTrip Plus.

Page 38: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-38 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit Breakers with MagneTrip UnitHow To OrderStationary Breakers and Special Purpose Hi-Break

Special Hi-Break Power Break Breaker with MagneTrip Trip Unit—Stationary GO-145M750 Vac, 700 Vdc, Interchangeable Trip Unit, Not UL Listed

Circuit Breaker Circuit Breaker ContinuousEnvelope Size Frame Size Current Rating Complete

(Amperes) (Amperes) (Amperes) Product Number 2 List Price

600 TUPMM7706 $21579.00

800 TUPMM7708 $21579.00

1000 TUPMM7710 $21579.00

3000 2500 1200 TUPMM7712 $21579.00

1600 TUPMM7716 $21579.00

2000 TUPMM7720 $21579.00

2500 TUPMM7725 $41660.00

3000 3000 TUPMM8730 $52905.00

4000 4000 4000 TUPMM97403,4 $84039.00

Power Break Breaker with Instantaneous Only—Stationary GO-145M600 Vac, 250 Vdc, Non-Interchangeable Trip Unit, Not UL Listed

Circuit Breaker Circuit Breaker ContinuousEnvelope Size Frame Size Current Rating Standard Break

(Amperes) (Amperes) (Amperes) Product Number List Price

1600 1600 1600 TPMM5616M $13890.00

2500 2000 TPMM7620M $14988.00

3000 2500 2500 TPMM7625M $28484.00

3000 3000 TPMM8630M $37577.00

4000 4000 4000 TPMM9640M2 $60399.00

14000-Ampere frame only2Product Number with standard trip functions. For optional trip functions and pricing, see page 5-39.380% rated4Non-interchangeable trip

Power Break Breaker with MagneTrip Trip Unit—Stationary, UL Listed, 100% Equipment Rated GO-145M600 Vac, 250 Vdc (Standard Break), 600 Vdc1 (Hi-Break) Non-interchangeable Trip Unit

Circuit Breaker Circuit Breaker ContinuousEnvelope Size Frame Size Current Rating Standard Break Hi-Break

(Amperes) (Amperes) (Amperes) Product Number 2 List Price Product Number 2 List Price

200 TPMM5602 $13890.00 THPMM5602 $14887.00

400 TPMM5604 $13890.00 THPMM5604 $14887.00

600 TPMM5606 $13890.00 THPMM5606 $14887.00

1600 1600 800 TPMM5608 $13890.00 THPMM5608 $14887.00

1000 TPMM5610 $13890.00 THPMM5610 $14887.00

1200 TPMM5612 $13890.00 THPMM5612 $14887.00

1600 TPMM5616 $13890.00 THPMM5616 $14887.00

4000 4000 4000 TPMM96402 $60399.00 THPMM96402 $73666.00

3000 Ampere Envelope Size Power Break with MagneTrip Trip Unit—Stationary, UL Listed, 100% Equipment Rated GO-145M600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit

Circuit Breaker Continuous Standard Break Hi-BreakFrame Size Current Rating Complete Complete(Amperes) (Amperes) Product Number 2 List Price Product Number 2 List Price

600 TPMM7606 $14988.00 THPMM7606 $18902.00

800 TPMM7608 $14988.00 THPMM7608 $18902.00

1000 TPMM7610 $14988.00 THPMM7610 $18902.00

2500 1200 TPMM7612 $14988.00 THPMM7612 $18902.00

1600 TPMM7616 $14988.00 THPMM7616 $18902.00

2000 TPMM7620 $14988.00 THPMM7620 $18902.00

2500 TPMM7625 $28484.00 THPMM7625 $36538.00

3000 3000 TPMM8630 $37577.00 THPMM8630 $46381.00

Page 39: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-39Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break Breaker with MagneTrip Trip Unit—Draw-Out UL Listed, 100% Equipment Rated GO-145M600 Vac, 250 Vdc (Standard Break), 600 Vdc1 (Hi-Break)Non-Interchangeable Trip Unit

Circuit Breaker Circuit Breaker Continuous Standard Break Hi-BreakEnvelope Size (Amperes) Frame Size (Amperes) Current Rating (Amperes) Product Number 2 List Price Product Number 2 List Price

200 TCMM5602 $17187.00 THCMM5602 $18450.00

400 TCMM5604 $17187.00 THCMM5604 $18450.00

600 TCMM5606 $17187.00 THCMM5606 $18450.00

1600 1600 800 TCMM5608 $17187.00 THCMM5608 $18450.00

1000 TCMM5610 $17187.00 THCMM5610 $18450.00

1200 TCMM5612 $17187.00 THCMM5612 $18450.00

1600 TCMM5616 $17187.00 THCMM5616 $18450.00

4000 4000 4000 TCMM9640 $71014.00 THCMM9650 $86462.00

Replacement MagneTrip Trip Units GO-148FContinuous Replacement Adjustable Inverted

Current Rating Trip Unit Current, Short-Time, Construction(Amperes) Product Number List Price Fixed Instantaneous List Price (Stationary Only) List Price

600 TPD706 $4497.00 TPDT06D $5572.00 TPDT06B $5741.00

800 TPDT08 $4497.00 TPDT08D $5572.00 TPD708B $5741.00

1000 TPDT10 $4497.00 TPDT10D $5572.00 TPDT10B $5741.00

1200 TPDT12 $4497.00 TPDT12D $5572.00 TPDT12B $5471.00

1600 TPDT16 $4497.00 TPDT16D $5572.00 TPDT16B $5471.00

2000 TPDT20 $4497.00 TPDT20D $5572.00 TPDT20B $5471.00

2500 TPDT25 $8544.00 TPDT25D $9619.00 TPDT25B $9788.00

3000 TPDT30 $11272.00 TPDT30D $12347.00 TPDT30B $12516.00

14000-Ampere frame only2Product Number with standard trip functions. For optional trip functions see table.3Add suffix code letter to end of breaker frame product numbers.4For trip option on new breaker, add to complete breaker list price above.

3000 Ampere Envelope Size Power Break Breaker with MagneTrip—Draw-Out, UL Listed, 100% Equipment Rated GO-145M600 Vac, 250 Vdc (Standard Break), 600 Vdc (Hi-Break) Interchangeable Trip Unit

Circuit Breaker Continuous Standard Hi-BreakFrame Size Current Rating Break Complete Complete(Amperes) (Amperes) Product Number 2 List Price Product Number 2 List Price

600 TCMM7606 $19814.00 THCMM7606 $24096.00

800 TCMM7608 $19814.00 THCMM7608 $24096.00

25001000 TCMM7610 $19814.00 THCMM7610 $24096.00

1200 TCMM7612 $19814.00 THCMM7612 $24096.00

1600 TCMM7616 $19814.00 THCMM7616 $24096.00

2000 TCMM7620 $19814.00 THCMM7620 $24096.00

– 2500 TCMM7625 $33702.00 THCMM7625 $42143.00

3000 3000 TCMM8630 $43859.00 THCMM8630 $53114.00

Optional MagneTrip Unit Functions3 GO-145M4

Description Product No. Suffix List Price Adder

Adjustable current plus adjustable short-time fixed instantaneous D $1075.00

Inverted construction (stationary breaker only) B $1244.00

Power Break I Circuit Breakers with Magne Trip Trip UnitHow To OrderStationary Breakers, Draw-Out Breakers

Page 40: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-40 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit Breakers with MicroVersaTrip Plus or PM Trip UnitsFrame Selection

Circuit Breaker Circuit Breaker SensorStandard Break1 Hi-Break1

Envelope Size Frame Size Rating Product Product(Amperes) (Amperes) (Amperes) Number List Price Number List Price

800 800 200 TP82TT $13815.00 THP82TT $14950.00

800 800 400 TP84TT $13815.00 THP84TT $14950.00

800 800 800 TP88TT $13815.00 THP88TT $14950.00

1600 1600 1000 TP1610TT $16890.00 THP1610TT $18779.00

1600 1600 1600 TP1616TT $16890.00 THP1616TT $18779.00

2000 2000 2000 TP2020TT $17917.00 THP2020TT $20985.00

3000 2500 1000 TP2510TT $19710.00 THP2510TT $23085.00

3000 2500 2000 TP2520TT $19710.00 THP2520TT $23085.00

3000 2500 2500 TP2525TT $34750.00 THP2525TT $43540.00

3000 3000 3000 TP3030TT $44230.00 THP3030TT $55435.00

4000 4000 4000 TP4040T2 $72945.00 THP4040T2 $88990.00

Frame Selection 3 for Use with MicroVersaTrip PM or Plus Trip Units

Circuit Breaker Circuit Breaker SensorStandard Break1 Hi-Break1

Envelope Size Frame Size Rating Product Product(Amperes) (Amperes) (Amperes) Number List Price Number List Price

800 800 200 TP82TTR $14305.00 THP82TTR $15440.00

800 800 400 TP84TTR $14305.00 THP84TTR $15440.00

800 800 800 TP88TTR $14305.00 THP88TTR $15440.00

1600 1600 1000 TP1610TTR $17375.00 THP1610TTR $19270.00

1600 1600 1600 TP1616TTR $17375.00 THP1616TTR $19270.00

2000 2000 2000 TP2020TTR $18405.00 THP2020TTR $21475.00

3000 2500 1000 TP2510TTR $20200.00 THP2510TTR $23570.00

3000 2500 2000 TP2520TTR $20200.00 THP2520TTR $23570.00

3000 2500 2500 TP2525TTR $35235.00 THP2525TTR $44030.00

3000 3000 3000 TP3030TTR $44715.00 THP3030TTR $55920.00

4000 4000 4000 TP4040TR2 $73430.00 THP4040TR2 $89480.00

Basic Frame Selection, Stationary, UL Listed, 100% Equipment Rated, Suitable for Reverse Feed GO-145CFrame Selection for Use with MicroVersaTrip Plus Trip Units Only

Basic Frame Selection, Draw-Out, UL-Listed, 100% Equipment Rated, Suitable for Reverse Feed GO-145CFrame Selection for Use with MicroVersaTrip Plus Trip Units Only

Circuit Breaker Circuit Breaker SensorStandard Break1 Hi-Break1

Envelope Size Frame Size Rating Product Product(Amperes) (Amperes) (Amperes) Number List Price Number List Price

800 800 200 TC82TT4,5 $16300.00 THC82TT4,5 $17475.00

800 800 400 TC84TT4,5 $16300.00 THC84TT4,5 $17475.00

800 800 800 TC88TT4,5 $16300.00 THC88TT4,5 $17475.00

1600 1600 1000 TC1610TT $21175.00 THC1610TT $23420.00

1600 1600 1600 TC1616TT $21175.00 THC1616TT $23420.00

2000 2000 2000 TC2020TT $22090.00 THC2020TT $25575.00

3000 2500 1000 TC2510TT $24295.00 THC2510TT $28130.00

3000 2500 2000 TC2520TT $24295.00 THC2520TT $28130.00

3000 2500 2500 TC2525TT $41940.00 THC2525TT $51595.00

3000 3000 3000 TC3030TT $52485.00 THC3030TT $64690.00

4000 4000 4000 TC4040T T $87415.00 THC4040T T $106070.00

Frame Selection3 for Use with MicroVersaTrip PM or Plus Trip Units

Circuit Breaker Circuit Breaker SensorStandard Break1 Hi-Break1

Envelope Size Frame Size Rating Product Product(Amperes) (Amperes) (Amperes) Number List Price Number List Price

800 800 200 TC82TTR4,5 $16785.00 THC82TTR4,5 $17965.00

800 800 400 TC84TTR4,5 $16785.00 THC84TTR4,5 $17965.00

800 800 800 TC88TTR4,5 $16785.00 THC88TTR4,5 $17965.00

1600 1600 1000 TC1610TTR $21660.00 THC1610TTR $23910.00

1600 1600 1600 TC1616TTR $21660.00 THC1616TTR $23910.00

2000 2000 2000 TC2020TTR $22380.00 THC2020TTR $26060.00

3000 2500 1000 TC2510TTR $24785.00 THC2510TTR $28615.00

3000 2500 2000 TC2520TTR $24785.00 THC2520TTT $28615.00

3000 2500 2500 TC2525TTR $42430.00 THC2525TTR $52080.00

3000 3000 3000 TC3030TTR $52975.00 THC3030TTR $65180.00

4000 4000 4000 TC4040TTR $87905.00 THC4040TTR $106555.00

1For frame modification, i.e. electrically operated, see page 5-42.2Not rated 100%.3Includes provision for MicroVersaTrip PM functions. Use for MicroVersaTrip Plus when connections for 24 Vdc trip unit control power required.4Up to 24 secondary disconnects. For up to 48 secondary disconnects, use Product Number TCL-TT or TCL-TTR and add $1600.00 to List Price.5Small frame size.

Page 41: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-41Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break Molded Case Switch—Stationary GO-145D600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break)

Switch Switch ContinuousEnvelope Size Frame Size Current Rating Standard Break Hi-Break

(Amperes) (Amperes) (Amperes) 600 Vac/500 Vdc List Price 600 Vac/600 Vdc List Price

800 800 800 TPYY36081 $5671.00 – –1600 1600 1600 TPYY56161 $7452.00 – –2000 2000 2000 TPYY66201 $8380.00 – –3000 2500 2000 TPYY7620 $8380.00 THPYY7620 $10481.00

3000 2500 2500 TPYY7625 $13335.00 THPYY7625 $16670.00

3000 3000 3000 TPYY8630 $22565.00 THPYY8630 $28204.00

4000 4000 4000 TPYY9640 $35794.00 THPYY9640 $44738.00

Power Break I Circuit BreakersStationary Switches, Draw-out Switches800-4000 Amperes600 Vac500 Vdc (250 Vdc where noted)Suitable for reverse feed

Power Break Molded Case Switch—Draw-Out GO-145D600 Vac, 500 Vdc (Standard Break), 600 Vdc (Hi-Break)

Switch Switch ContinuousEnvelope Size Frame Size Current Rating Standard Break Hi-Break

(Amperes) (Amperes) (Amperes) 600 Vac/500 Vdc List Price 600 Vac/600 Vdc List Price

800 800 800 TCYY36081 $7384.00 – –1600 1600 1600 TCYY56161 $10751.00 – –2000 2000 2000 TCYY66201 $11683.00 – –3000 2500 2000 TCYY7620 $13205.00 THCYY7620 $15304.00

3000 2500 2500 TCYY7625 $18552.00 THCYY7625 $21889.00

3000 3000 3000 TCYY8630 $28843.00 THCYY8630 $34482.00

4000 4000 4000 TCYY9640 $46411.00 THCYY9640 $55355.00

1Rated 250 Vdc

Page 42: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-42 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit BreakersFrame Modification Features

800 1600 2000 3000 4000

120 Vac E1 E1 E1 E1 E1 $4475.00

240 Vac $4930.00

Add suffix FC to Product No.4

Supplied as standard

No price adder

$148.00

Price adder is on trip unit only

Price adder is on trip unit only

Function1

Circuit Breaker Envelope Size (Amperes)

List Price Adder

N/AN/A N/A E2 3 E2 3

Front Connected

Hidden "ON" Button

High Range Instantaneous (Air Core Sensors)

Zone Selective Interlock Wiring Terminal Block

Suitable for front or rear connection as standard

Add suffix C to frame Product Number

Add suffix H to frame Product Number5

Add suffix Z to frame Product Number when zone interlock function is included in trip unit (Z1 or Z2).

Requires 24 Vdc Control power.

5Not available on 4000A stationary breakers.

1Modification suffix must be developed in the following order: H/Z/FC/E1-7/C, ending with R: TP82TTE1CR.2Shunt trip or undervoltage release included with motor operation (specify with order).3Not UL Listed.4Stationary frames only.

125 Vdc E3 E3 E3 E3 E3 $4930.00

24 Vdc E5 E5 E5 E5 E5 $4930.00

48 Vdc E6 E6 E6 E6 E6 $4930.00

72 Vdc E7 E7 E7 E7 E7 $5380.00

Electrical (Motor)

Operation2

TC3030TT

Power Break Frame Modification Suffix—AC and DC Breakers GO-145C

Page 43: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-43Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit Breakers with EnhancedMicroVersaTrip Plus and MicroVersaTrip PM Trip UnitsHow To OrderTrip Unit Characteristics and Selection

Power Break Basic MicroVersaTrip Trip Unit Selection

Circuit Breaker Envelope Size (Amperes)

Circuit Breaker Frame Size (Amperes) Sensor Rating (Amperes)

Basic Trip Unit Product Number

200 C202

400 C204

800 C208

1000 C210

1600 C216

2000 2000 2000 C220

1000 C210

2000 C220

2500 C325

3000 3000 C330

4000 4000 4000 C440

30002500

800 800

1600 1600

Power Break Trip Unit Suffix SelectionMicroVersaTrip Plus with Selectable Phase Ammeter—Trip Indicators Standard

Trip Unit Suffix 1

List Price Adder, GO-145C 1

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (S)

Inst. (I)

High Inst. (H)

Ground 2 Fault 3

(G)GF Zone

Interlock (Z1) 4GF/ST Zone

Interlock (Z2) 4

LI $690.00 •

LIG $2205.00

LIGZ1 $2875.00

LSI $2260.00

LSIG $3772.00

LSIGZ1 $4445.00

LSIGZ2 $5120.00

LSH $3105.00

LSHG $4310.00

LSHGZ1 $5290.00

LSHGZ2 $5965.00

5Not available on 4000A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.

1Add suffix to basic trip unit product number. Make List Price addition for trip unit suffix. 2For single-phase 3-wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately from page 5-46.3Use code GD in place of G for a defeatable Ground Fault Option (not UL listed) i.e. LSIGD, and add $575.00 to list price.4Requires purchase of zone selective interlock module(s) Type TIM1 (120 Vac control voltage). List Price $402.00, GO-245B.

Adjustable Instantaneous

Fixed High Range Instantaneous5

probe
Page Update September
Page 44: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-44 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit Breakers with EnhancedMicroVersaTrip Plus and MicroVersaTrip PM Trip UnitsHow To OrderTrip Unit Characteristics and Selection (continued)

Power Break Trip Unit Suffix SelectionMicroVersaTrip PM with Metering and Communications—Trip Indicators Standard 1

Trip Unit Suffix2

List Price Adder, GO-145C 2

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (S)

Inst. (I)

High Inst. (H)

Ground 3 Fault (G)4

GF Zone Interlock (Z1) 5

GF/ST Zone Interlock (Z2) 5

LIM $2415.00 •

LIGM $3930.00

LIGZ1M $4600.00

LSIM $3985.00

LSIGM $5497.00

LSIGZ1M $6170.00

LSIGZ2M $6845.00

LSHM $4830.00

LSHGM $6345.00

LSHGZ1M $7015.00

LSHGZ2M $7690.00

Adjustable Instantaneous

Fixed High Range Instantaneous6

Trip Unit Suffix 2

List Price Adder, GO-145C 2

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (S)

Inst. (I)

High Inst. (H)

Ground 3 Fault (G) 4

GF Zone Interlock (Z1) 5

GF/ST Zone Interlock (Z2) 5

LIP $1955.00 •

LIGP $3470.00

LIGZ1P $4140.00

LSIP $3525.00

LSIGP $5037.00

LSIGZ1P $5710.00

LSIGZ2P $6385.00

LSHP $4370.00

LSHGP $5885.00

LSHGZ1P $6555.00

LSHGZ2P $7320.00

Adjustable Instantaneous

Fixed High Range Instantaneous 6

Trip Unit Suffix2

List Price Adder, GO-145C 2

Trip Indicators

Selectable Phase Ammeter

Long-Time (L)

Short-Time (S)

Inst. (I)

High Inst. (H)

Ground 3 Fault (G)4

GF Zone Interlock (Z1)5

GF/ST Zone Interlock (Z2)5

LIPM $3680.00 •

LIGPM $5265.00

LIGZ1PM $5865.00

LSIPM $5250.00

LSIGPM $6762.00

LSIGZ1PM $7435.00

LSIGZ2PM $8110.00

LSHPM $6095.00

LSHGPM $7610.00

LSHGZ1PM $8280.00

LSHGZ2PM $8955.00

4Use code GD in place of G for defeatable Ground Fault Option (not UL listed) i.e. LSIGDPM, and add $575.00 to List Price.5Requires purchase of zone selective interlock module(s) Type TIM1 (120 Vac control voltage).

List Price $402.00, GO-245B.

6Not available on 4000A stationary breaker frame. Requires frame with "H" suffix code. See page 5-40.

1Requires 24 Vdc control power and frame with TT…R suffix. See page 5-40.

Adjustable Instantaneous

Fixed High Range Instantaneous6

2Add suffix to basic trip unit product number. Make List Price addition for trip unit suffix. Requires frame with TT…R suffix. See page 5-40.3For single-phase 3-wire or 3-phase, 4-wire applications, order appropriate neutral current sensor and price separately from page 5-46.

Power Break Trip Unit Suffix SelectionMicroVersaTrip PM with Protective Relays and Communications—Trip Indicators Standard 1

Power Break Trip Unit Suffix SelectionMicroVersaTrip PM with Metering, Protective Relays and Communications—Trip Indicators Standard 1

probe
Page Update September
Page 45: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-45Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersHow To OrderRating Plug Selection

Power Break Rating Plus Selection1 GO-245AAll Plugs List Priced at $89.00

Frame Size Sensor Rating Current Rating Rating Plug(Amperes) (Amperes) (Amperes) Product Number

100 TR2B100200 150 TR2B150

200 TR2B200150 TR4B150200 TR4B200

400225 TR4B225250 TR4B250

800 300 TR4B300400 TR4B400300 TR8B300400 TR8B400450 TR8B450

800 500 TR8B500600 TR8B600700 TR8B700800 TR8B800400 TR10B400

1000 600 TR10B600800 TR10B8001000 TR10B1000

1600 600 TR16B600800 TR16B800

1600 1000 TR16B10001100 TR16B11001200 TR16B12001600 TR16B1600750 TR20B750800 TR20B8001000 TR20B1000

2000 2000 1200 TR20B12001500 TR20B15001600 TR20B16002000 TR20B2000400 TR10B400

1000 600 TR10B600800 TR10B8001000 TR10B1000750 TR20B750800 TR20B800

2500 1000 TR20B10002000 1200 TR20B1200

1500 TR20B15001600 TR20B16002000 TR20B20001600 TR25B1600

2500 2000 TR25B20002500 TR25B25001200 TR30B12001600 TR30B1600

3000 3000 2000 TR30B20002500 TR30B25003000 TR30B30001600 TR40B16002000 TR40B2000

4000 4000 2500 TR40B25003000 TR40B30003600 TR40B36004000 TR40B4000

1Rating plug removal tool. Product Number TRTOOL, $12.00, GO-135S.

Page 46: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-46 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit BreakersNeutral Current Sensors and POWER LEADER Accessories

MicroVersaTrip Portable Test Kit GO-245BThe test kit product number TVRMS2 is a portable, battery-powered,test kit which provides for trip unit health checks and functional tripand no-trip tests. It also provides defeat of the ground-fault functionand can be used in conjunction with high-current test equipment.The test kit can be used to provide +24V power to the trip unit forcold set-up and viewing of trip targets. This test kit is for use withRMS-9, Epic, MicroVersaTrip Plus and MicroVersaTrip PM trip units.The kit uses six rechargeable ni-cad or standard alkaline "D" cellssupplied by the customer. Kit can also be powered by 120 Vacsource.

Description Product Number List Price

Portable Test Kit TVRMS2 $3000.00

MicroVersaTrip Portable Power Pack GO-245BThe handheld MicroVersaTrip portable battery pack provides anindependent power source for Enhanced MicroVersaTrip Plus andMicroVersaTrip PM trip units as an alternative to the TVRMS2 testset. The power pack is used to power up the trip unit to set or adjusttrip set points when the breaker is on the bench or otherwise notpowered up. It connects to the trip unit through the rating plug testjack. It requires three (3) standard 9Vdc alkaline batteries (notincluded). Product number TVPBP List Price, $75.00, GO-245A.

Description Product Number List Price

MicroVersaTrip Plus and PMPortable Power Pack TVPBP $75.00

POWER LEADER Power Supplies G0-104APower supply for furnishing 24Vdc control power for MicroVersaTripPlus and PM trip units. Two versions are available: a 4.0 ampere ver-sion with AC and DC input voltages and a 0.8 ampere version capa-ble of operating from 120/230 Vac. Both power supplies have inher-ent transient protection circuits.

System Requirements ProductDescription (price separately) Number List Price

4.0 ampere power supplyPrice one PLPS4G01 for

each line-up. 60 trip units Input power, 100VAand 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 $1250.00

POWER LEADER Voltage Conditioner G0-104AConditions and scales 120 Vac to 1.76 Vac for use by the trip unit forvoltage sensing. Provides transient protection. Voltage conditionersrequire isolation PTs.

System Requirements ProductDescription (price separately) Number List Price

Supplies isolated busvoltage signal to One set of 3 voltage conditioners

MicroVersaTrip PM required for each voltage sensing $200.00

trip units. location. PTs also required. PLVC1G01 per set

Neutral Current Sensors1 GO-245BCircuit Breaker Neutral Sensor

Breaker Frame Sensor Rating Rating or Tap Product(Amperes) (Amperes) Settings (Amperes) Number List Price

200 200 TSVG302 $266.00

800 400 400/200 TSVG304A $266.00

400 600/3002 TSVG306A $266.00

800-1600 800 800/400 TSVG308A $266.00

1000 800/4002 TSVG808A $266.00

1600 1000 1000/500 TSVG810A $266.00

1600 1200/6002 TSVG812A $266.00

1600 1600/1000 TSVG816A $266.00

2000 2000 2000/1000 TSVG820A $266.00

1000 800/4002 TSVG808A $266.00

1000 1000/500 TSVG810A $266.00

1000 1200/6002 TSVG812A $266.00

3000 1000 1600/10002 TSVG816A $266.00

2000 2000/1200 TSVG820A $266.00

2500 2500/1800 TSVG825A $266.00

3000 3000/2400 TSVG830A $266.00

4000 4000 4000/3000 TSVG940A $266.00

1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.2For use with multiple source ground fault protection schemes. Rating does not match

MicroVersaTrip Plus or PM frame sensor.

Neutral Current Sensor

Rating Plug Removal Tool GO-135SProduct Number List Price

TRTOOL $12.00

ReferenceInstructions GEH-5946

Page 47: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-47Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

C/D E

Remote Close Solenoid, Remote Charge Indicator

Shunt Trip 2 UVR

Blown Fuse Trip

Shunt Trip

Bell Alarm

Auxiliary Switch

Electrical Operator

800, 1600 and 2000 1 1– 123 4 5

3000 and 4000 1 123 4 5,6

3Deduct two auxiliary switches per shunt trip device. Deduct one auxiliary switch for all MicroVersaTrip breaker frames with a "TTR" suffix, i.e. all MicroVersaTrip PM and MicroVersaTrip Plus with provision for trip unit control power.4Electrically operated breakers require the addition of a shunt trip or UVR for remote opening.5All leads exit left side except auxiliary switches. Leads for first six switch elements (4 when shunt trip is used) exit left. The remaining switch element leads exit right.6Blown fuse trip, remote close solenoid, remote charge indication—leads exit right.

One of each

Any one Any one

2For 3000 and 4000 ampere envelope size breakers the shunt trip will be located in position "B" (product number TSST—L, leads out left) unless a bell alarm is also required.

1800-ampere draw-out also available with up to 48 secondary disconnects. Refer to page 5-51.

Circuit Breaker Envelope Size (Amperes)

Mounting Position (See Figures Above)

Accessory Lead Exit From Breaker

A B

Maximum Accessories Available Per Breaker Mounting Position (See Figures Above)

Maximum Internal Accessories Available per Breaker

A

C

B

D

Fig. 1. Accessory location800, 1600 and 2000-ampere envelope sizes

A

C

B

D

Fig. 2. Accessory location.3000 and 4000-ampere envelope sizes

E

Fig. 3. Electrical operator locationAll breakers

Power Break I Circuit BreakersStationary and Draw-out Breaker Accessories

All internally mounted accessories are UL Listed when field installed(except where noted) in MicroVersaTrip breakers and MagneTripbreakers with interchangeable trip units. These devices mountwithin the breaker envelope as shown to the right.

The control leads exist in pigtail form from the breaker side. Theseleads are terminated at secondary disconnect points for draw-outbreakers or optional terminal blocks when specified for stationarybreakers. All leads are color coded.

When ordered with draw-out circuit breaker a maximum of 48secondary disconnects can be supplied (a maximum of 24 secondarydisconnects for standard 800-ampere draw-out1). If the combinationof accessories and functions ordered per breaker require more thanthe maximum secondary disconnects allowed, the breaker will bewired according to standard manufacturing procedure; excess leadswill be left unwired (or customer can specify that all leads be leftunwired). See page 5-51 to determine the number of secondarydisconnects required for each device or function.

Refer to table below for accessory combinations, mounting positionsand lead exit information. Most accessories are available for fieldinstallation and replacement by specifying the appropriate productnumber. Instruction bulletins are included with each device.

All electrically operated breakers include a shunt trip or undervolt-age release for remote opening. Specify the electrical chargingvoltage and trip device voltage separately. The price of theelectrical function will automatically include the price of one shunttrip or undervoltage release (UVR); specify desired device andvoltage with order.

Page 48: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-48 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit BreakersAccessoriesAll devices UL Listed for factory or field installation except where noted.

Remote Charge Indication for Manual Breakers (Factory Installed Only) GO-145ACircuit Breaker Product

Envelope Size (Amperes) Number List Price

800, 1600, 2000 TPXCAS $488.00

3000, 4000 TSXCAS $488.00

Padlock On Button 2 for Manual Breakers (Factory Installed Only) GO-145ACircuit Breaker Product

Envelope Size (Amperes) Number List Price

800, 1600, 2000 TPXPL $111.00

3000, 4000 TSXPL $96.50

2Permits padlocking of the (local) breaker ON (close) button to prevent overriding the remote close function.

Shunt Trip GO-145AShunt trip provides remote control tripping of the breaker. Integral cut-off switch automati-cally de-energizes trip coil when breaker opens. It meets UL requirement for service onground fault systems.

Field Installable Product Numbers4 Factory Installed Product Numbers

Breaker Envelope Size (Amperes)

Coil Rating 800, 1600 2500, 3000 800, 1600 3000Vac and 2000 and 40003 and 2000 and 40003 List Price

120, 240 TPST12 TSST12R, L TPST12S TSST12RS, LS $630.00

480, 600 TPST13 TSST13R, L TPST13S TSST13RS, LS $630.00

Coil RatingVdc

12 TPST7 TSST7R, L TPST7S TSST7RS, LS $630.00

24 TPST8 TSST8R, L TPST8S TSST8RS, LS $630.00

48 TPST9 TSST9R, L TPST9S TSST9RS, LS $630.00

125 TPST10 TSST10R, L TPST10S TSST10RS, LS $630.00

250 TPST11 TSST11R, L TPST11S TSST11RS, LS $630.00

3R" (right) and "L" (left) refer to accessory mounting location. When shunt trip used with blown fuse detector or UVRspecify "L". Use "R" with bell alarm. Normal lead exit is left side unless bell alarm is present.

4To order a shunt trip for new installation on a breaker with an existing auxiliary switch contact your local GE SalesOffice for information.

Remote Close Solenoid with Remote Charge Indication1 for Manual Breakers (Factory Installed Only) GO-145A

Circuit Breaker Control ProductEnvelope Size (Amperes) Voltage Number List Price

120 Vac TPXCC12S $658.00

800, 1600, 2000 240 Vac TPXCC14S $658.00

24 Vac TPXCC08S $658.00

120 Vac TSXCC12S $658.00

3000, 4000 240 Vac TSXCC14S $658.00

24 Vac TSXCC08S $658.00

1Replacement solenoid only. Order product number TPXEC** or TSXEC** (add voltage suffix: 12, 14 or 08). List Price$658.00, GO-148C.

NOTE: Use of an OFF button actuated motor cut-off switch is recommended for electrically operated circuit breakerswired for remote close. Order Product Number TAPD1, List Price $520.00, GO-145A.

Page 49: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-49Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Blown Fuse Trip (Three Coil Shunt Trip) GO-145AProvides single-phase protection for fuse and breaker combinations by automatically trip-ping the breaker when a fuse blows. Suitable for system voltages of 120/208 to 600 Vac. Doesnot protect when source single phases.

UnderVoltage Release (UVR) GO-145AAutomatically trips breaker when applied UVR coil voltage drops to 30-70% of rated value.

Bell Alarm with Lock-out GO-145ASingle-pole, double-throw (AB-type) switch element. Used for remote indication of breakertrip when caused by overload, short circuit or ground fault conditions only. Switch elementratings are identical to those listed for Auxiliary Switch Accessories. Bell alarm distinguishesbetween overcurrent trip and manual/shunt/UVR trip.

Field Installable Product Numbers Factory Installed Product Numbers

Breaker Envelope Size (Amperes)

Coil Rating 800, 1600 3000 800, 1600 3000Vac and 2000 and 4000 and 2000 and 4000 List Price

120 TPUV1 TSUV1 TPUV1S TSUV1S $630.00

240 TPUV2 TSUV2 TPUV2S TSUV2S $630.00

480 TPUV4 TSUV4 TPUV4S TSUV4S $630.00

600 TPUV6 TSUV6 TPUV6S TSUV6S $630.00

Coil RatingVdc

12 TPUV7 TSUV7 TPUV7S TSUV7S $630.00

24 TPUV8 TSUV8 TPUV8S TSUV8S $630.00

48 TPUV9 TSUV9 TPUV9S TSUV9S $630.00

125 TPUV10 TSUV10 TPUV10S TSUV10S $630.00

250 TPUV11 TSUV11 TPUV11S TSUV11S $630.00

Field Installable Product Numbers Factory Installed Product Numbers

Breaker Envelope Size (Amperes)

System 800, 1600 3000 800, 1600 3000Voltage and 2000 and 4000 and 2000 and 4000 List Price

208 to 600 Vac TPST316 TSST316 TPST316S TSST316S $1530.00

Factory Installed Product Numbers1

Breaker Envelope Size (Amperes)

Breaker 800, 1600 3000Type and 2000 and 4000 List Price

MagneTrip TPMBAS TSBAAS $259.00

Solid State TPSBAS TSSBAAS $259.00

1Not available for field installation except as replacement (delete S).

Power Break I Circuit BreakersAccessoriesAll devices UL Listed for factory or field installation except where noted.

Description Product Number List Price

Time Delay Module(0.1 to 1.0 second delay) SPUVTD $430.00

Time Delay Module for UVR GO-245BThe time delay module prevents nuisance tripping due to momentary loss of voltage.The module has 120 Vac input and 125 Vdc output and must be used with the 125 Vdc UVR.

Page 50: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-50 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Power Break I Circuit BreakersAccessoriesAll devices UL Listed for factory or field installation except where noted.

600 Vac, Not UL ListedField Installable Product Numbers Factory Installed Product Numbers

Breaker Envelope Size (Amperes)No. of SPDT

Switch Elements 800, 1600 3000 800, 1600 3000 List Price(Contacts) and 20001 and 40001 and 2000 and 4000 GO-145A

1 TPAS6AB1 TSAS6AB1 TPAS6AB1S TSAS6AB1S $251.00

2 TPAS6AB2 TSAS6AB2 TPAS6AB2S TSAS6AB2S $503.00

3 TPAS6AB3 TSAS6AB3 TPAS6AB3S TSAS6AB3S $534.00

4 TPAS6AB4 TSAS6AB4 TPAS6AB4S TSAS6AB4S $562.00

5 TPAS6AB5 TSAS6AB5 TPAS6AB5S TSAS6AB5S $623.00

6 TPAS6AB6 TSAS6AB6 TPAS6AB6S TSAS6AB6S $680.00

7 – – TPAS6AB7S TSAS6AB7S $924.00

8 – – TPAS6AB8S TSAS6AB8S $1180.00

9 – – TPAS6AB9S TSAS6AB9S $1215.00

10 – – TPAS6AB10S TSAS6AB10S $1240.00

11 – – TPAS6AB11S3 TPAS6AB11S3 $1300.00

124 – – TPAS6AB12S3 TSAS6AB12S3 $1365.00

1Mounts in right pole only when shunt trip specified.2Field installed auxiliary switches and shunt trips must mount on opposing poles only.3Not available on breakers equipped with a shunt trip.4Not available on MicroVersaTrip PM breakers or breakers equipped with MicroVersaTrip Plus and provisions for

trip unit control power.

Auxiliary SwitchSingle-pole, double-throw (AB-type) switch elements. Used for remote indication of breakermain contact position (on/closed or off/opened).

Switch element ratings: 1/4 ampere at 250 Vdc; 1/2 ampere at 125 Vdc; 6 amperes at 240 or600 Vac.

Refer to page 5-47 footnote (3) for limits on maximum number in combination with otheraccessories.

240 Vac, 125 VdcField Installable Product Numbers Factory Installed Product Numbers

Breaker Envelope Size (Amperes)No. of SPDT

Switch Elements 800, 1600 3000 800, 1600 3000 List Price(Contacts) and 20001 and 40002 and 2000 and 4000 GO-145A

1 TPAS2AB1 TSAS2AB1 TPAS2AB1S TSAS2AB1S $251.00

2 TPAS2AB2 TSAS2AB2 TPAS2AB2S TSAS2AB2S $503.00

3 TPAS2AB3 TSAS2AB3 TPAS2AB3S TSAS2AB3S $534.00

4 TPAS2AB4 TSAS2AB4 TPAS2AB4S TSAS2AB4S $562.00

5 TPAS2AB5 TSAS2AB5 TPAS2AB5S TSAS2AB5S $623.00

6 TPAS2AB6 TSAS2AB6 TPAS2AB6S TSAS2AB6S $680.00

7 – – TPAS2AB7S TSAS2AB7S $924.00

8 – – TPAS2AB8S TSAS2AB8S $1180.00

9 – – TPAS2AB9S TSAS2AB9S $1215.00

10 – – TPAS2AB10S TSAS2AB10S $1240.00

11 – – TPAS2AB11S3 TPAS2AB11S3 $1300.00

12 – – TPAS2AB12S3 TPAS2AB12S3 $1365.00

probe
Page Update September
Page 51: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-51Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersDraw-Out Breakers Accessories

Bypass Switch GO-245BProvides positive indication that the draw-out breaker or switchprimary contact fingers are fully connected to the main bus in thesubstructure. Switch contacts change states only after the primaryfingers are fully connected when the breaker is being moved fromthe DISCONNECTED position through the TEST position and into theCONNECTED position.

May be used to provide control circuit continuity or downstreamsignaling that the draw-out breaker is connected in addition to thevisual position indicator on the draw-out substructure. The By-passswitch accessory does not indicate either the TEST or DISCONNECTEDposition. The switch assembly mounts on the stationary frame andthe actuator mounts to the carriage. Switch contacts are rated at10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.

Draw-Out Accessories GO-145AFrame Rating Product

Description (Amperes) Number List Price

Mechanical Interlock, 800-2000 TDOWB1 $712.00

Horizontal Interconnect 2500-4000 TDOWB2 $712.00

Mechanical Interlock, 800-2000 TDOWB3 $712.00

Vertical Interconnect 2500-4000 TDOWB4 $712.00

800 TDOSS08 $1155.00

Shutters 1600-2000 TDOSS20 $1155.00

2500-3000 TDOSS30 $1155.00

4000 TDOSS40 $1155.00

Padlock Device All TDOPC $46.005

Lifting Bar All TDOLB4 $104.005

Racking Tool All TDORT4 $70.005

Product Number Product NumberStandard Break Hi-Break1

Frame Rating Max. Ampere(Amperes) Rating Manual Electric List Price Manual Electric List Price

8001 800 TDOS08 TDOS08E $1545.00 THDOS08 THDOS08E $1670.00

800 800 TDOS08L TDOS08LE $2990.00 THDOS08L THDOS08LE $3230.00

1600 1600 TDOS16 TDOS16E $2990.00 THDOS16 THDOS16E $3230.00

2000 2000 TDOS20 TDOS20E $4355.00 THDOS20 THDOS20E $4695.00

2500 2000 TDOS25 TDOS25E $4715.00 THDOS25 THDOS25E $5080.00

2500 2500 TDOS25 TDOS25E $4715.00 THDOS25 THDOS25E $5080.00

3000 3000 TDOS30 TDOS30E $6300.00 THDOS30 THDOS30E $6790.00

4000 4000 TDOS40 TDOS40E $15910.00 THDOS40 THDOS40E $17150.00

Description Product Number List Price

Bypass Switch for 800 through 4000 Amperes:2 Elements TDOBP2L $177.00

4 Elements TDOBP4L $256.00

6 Elements TDOBP6L $336.00

Number of Secondary Disconnect Circuits Required per Auxiliary Device 2

Device/Function Required Number

Neutral Sensor Leads (MicroVersaTrip only) 2Electrical Operation 6Auxiliary Switch per Element 3Undervoltage Release 2Bell Alarm 3Shunt Trip 2Blown Fuse Trip 6Remote Close Solenoid and Charge indication 3Remote Charge indication 2

OEM Substructures GO-145AAllows a maximum of 48 secondary disconnects (except where noted); required for trip units and breaker control functions.

Secondary Disconnects for Draw-out Breakers GO-145AField installation kits; 48 circuits maximum per draw-out. (24 maximum for standard 800 ampere draw-out).

Description Product Number List Price

Substructure Disconnect Kit 6 Circuits TDOSD6S3 $320.00

Breaker Disconnect Kit 6 Circuits TDOSD6B $278.00

Substructure Disconnect withZone Interlocking Z1 or Z2 Suffix TDOSVD04 $144.00

Substructure Disconnect for24V dc Trip Unit Control Power Only TDOSVD02 $166.00

Substructure Disconnectfor MicroVersaTrip PM Functions

and Zone Selective Interlocking (Z1/Z2) TDOSVD12 $166.00

Position Switch GO-245BProvides positive indication when the draw-out breaker or switchprimary contact fingers have been fully withdrawn from the main busconnections. Switch contacts change state only after the primaryfingers are fully disconnected when the breaker is being moved fromthe CONNECTED position through the TEST position and into theDISCONNECTED position.

May be used as part of a safety interlocking system in addition tothe visual indicator on the draw-out substructure. The PositionSwitch accessory does not indicate either the TEST or CONNECTEDposition. The switch assembly mounts on the stationary frame andthe actuator mounts to the carriage. Switch contacts are rated at10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.

Number of Switch Elements Product Number List Price

2 NO/2 NC SDOPS2L $177.00

4 NO/4 NC SDOPS4L $256.00

6 NO/6 NC SDOPS6L $336.00

1Allows up to 24 secondary disconnects. See table below to determine number of secondary disconnects required.2Breaker accessories ordered for field installation require a corresponding set of breaker mounted secondary disconnects. Refer to table above for quantity.3Secondary disconnects for substructure portion must be ordered and priced separately. For factory installation, so specify.4One lifting bar and one racking tool supplied with every five draw-out breakers at no charge.5GO-245BNOTE: Breaker portion of secondary disconnects supplied at no charge when accessories are ordered with breaker. MicroVersaTrip draw out breakers are provided as standard

with secondary disconnect positions for possible neutral current sensor leads.

Page 52: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-52 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

Terminal Block (Factory Installed Only) GO-145AOffers an external means of terminating accessory leads at the breaker. A maximum of 18terminals can be supplied on each side of the breaker (36 terminals total). For stationarybreakers only. Terminal blocks are rated 10 amperes at 600 Vac.

Factory Installed Product Numbers

Breaker Envelope Size (Amperes)

800, 1600 3000Terminals and 20001 and 4000 List Price

6 TPTB1R, L TSTB1R, L $158.00

12 TPTB2R, L TSTB2R, L $221.00

18 TPTB3R, L TSTB3R, L $286.00

24 TPTB4L – $444.00

30 TPTB5L – $508.00

36 TPTB6L – $573.00

1Left side only on frames with MicroVersaTrip trip units.

Power Break I Circuit BreakersAccessoriesAll devices UL Listed for factory or field installation except where noted.

Kirk Key Provision GO-145APermits sequencing of breaker operations with other key-type devices. The key remainscaptured in frame except when the breaker has been locked in the OPEN position. The KirkKey provision must be factory installed on 3000 and 4000 ampere envelope sizes. Customer toprovide Kirk Key lock device(s). (Key removable when bolt extended).

Note: Any breaker installed with Kirk Key provision must be replaced with a similarlyprovisioned breaker.

Circuit Breaker MaximumEnvelope Trip Number Factory Field

Size (Amperes) Device of Locks Installed List Price Installed2 List Price

1 TPK01 $817.00 TPK01F $773.00

800, 1600 MicroVersaTrip 2 TPK02 $817.00 TPK02F $773.00

and 20003 or MagneTrip 3 TPK03 $817.00 TPK03F $773.00

4 TPK04 $817.00 TPK04F $773.00

3000 MagneTrip4 6 TSK16 $817.00 – –and 4000 MicroVersaTrip 6 TSK26 $817.00 – –

2Cannot be assembled on a breaker with padlock type TSPL or TSPDL.3UL Listed for factory or field installation.4Includes molded case switch.

Zero Bolt ProtectionTPK01, TPK01B Type FTPK02 Type M2FTPK03 Type M3FTPK04 Type M4F

One-inch Bolt ProtectionTSK16, TSK26 Type F

Type M2FType M3FType M4FType M5FType M6F

Door Interlock and Padlock GO-145ADoor interlock and padlock prevents opening enclosure door when breaker is closed. Available for stationary or draw-out construction.Supplied with breaker padlock suitable for use with three locks (locks supplied by purchaser). Padlock enables breaker to be locked in anopen position with up to three (3) padlocks—meets California code. Padlocks supplied by purchaser.

Product Number

Padlock and Defeatable Padlock and Non-defeatableDoor Interlock6 Door Interlock

Circuit BreakerEnvelope Size Breaker Trip Standard Standard

(Amperes) Operation Device Break List Price Hi-Break List Price Break List Price Hi-Break List Price

800, 1600, Manual or MicroVersaTrip2000 Electrical or Magne Trip TSPDL8 $398.00 TSPDL8 $398.00 TSPL8,9 $106.00 TSPL8,9 $106.00

Manual or3000, 4000 Electrical7 MicroVersaTrip TPSSDIPL $398.00 THSSDIPL $398.00 TPSSLDA10 $103.00 THSSLDA10 $109.00

3000, 4000 Manual MagneTrip TPSDIPL $423.00 THSDIPL $398.00 TPSLDA10 $106.00 THSLDA10 $98.50

3000, 4000 Electrical7 MagneTrip TPSEDIPL $423.00 THSEDIPL $398.00 TPSLDEA10 $106.00 THSLDEA10 $114.00

6Door interlock is defeatable with a small tool to allow authorized access.7OFF button actuated motor cut-off switch for electrically operated 3000 and 4000 ampere envelopes is available. Order Product Number TAPD1, List Price $520.00, GO-145A.8Not available for breakers supplied with Kirk Key provision. Factory installed only.9Padlock and non-defeatable door interlock.10Padlock only.

Page 53: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Publications and Reference: See Section 21 for a list of additional product-related publications

Prices and data subject to change without notice

www.geelectrical.com BuyLog Catalog 5-53Rev. 12/04

Insulated Case Circuit Breakers

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Power Break I Circuit BreakersAccessoriesAll devices UL Listed for factory or field installation except where noted.

Walking Beam Interlock for Stationary Breakers—Not UL Listed GO-145ACircuit Breaker Product

Envelope Size (Amperes) Number List Price

800, 1600, 2000 TPWB $525.00

3000 TSWB $569.00

Contact GE Sales office for availability of walking beam for 4000A frame.

Adapter Kits GO-245BPremounts to bus structure allowing cabling or bussing to be completed prior to breakermounting. Accepts either lugs or crimp type connector terminals. Product number includesadapter and hardware for three-pole line side, or three-pole load side connection.

Circuit BreakerEnvelope Size Suitable for

(Amperes) use with up to: Product Number List Price

3 TPLUG108 Lugs800 or 3 Crimp Lugs1 per Pole TPLUGA08 $78.50

6 TPLUG108 Lugs1600 or 6 Crimp Lugs1 per Pole TPLUGA162 $389.00

6 TPLUG108 Lugs2000 or 6 Crimp Lugs1 per Pole TPLUGA20 $487.00

1Anderson No. VCEL-075-12H1 or equivalent2T-studs—TP16FCA—included with adapter

800A Power Break with TPLUGA08 adapter and 9

TPLUG108 lugs

1600A Power Break with TPLUGA16 adapter and 6

TPLUG108 lugs

Lug Kits GO-245BKits accept Cu/AI wire and are suitable for direct mounting to the breaker. When order-ing Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugsfor the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs.

When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use ofT-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would beQty 1-TSLUG25. T-Studs would also be required.

Circuit Breaker Max. WireFrame Size Max. Rating Product Lugs Cables Range(Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI List Price

800 400 TPLUG106 1 1 (1) #2-600 $18.50

800 600 TPLUG206 1 2 (1) #2-600 $27.50

800 800 TPLUG308 1 3 (3) 300-750 $32.00

800 800 TPLUG1083 1 3 3/0-800 $23.00

1600 1600 TPLUG1083 1 6 3/0-800 $23.00

1600 1600 TPLUG408 1 4 500-800 $39.00

2000 2000 TPLUG1083 1 6 3/0-800 $23.00

3000 800 TSLUG08 9 3 3/0-800 $274.00

3000 1200 TSLUG12 12 4 3/0-800 $296.00

3000 1600 TSLUG16 15 5 3/0-800 $345.00

3000 2000 TSLUG20 18 6 3/0-800 $383.00

3000 2500 TSLUG25 21 7 3/0-800 $418.00

3000 3000 TSLUG30 27 9 3/0-800 $630.00

4000 4000 TSLUG40 33 11 3/0-800 $1045.00

3For use with adapter kit only. See table above.

Type PLUG206 Type TPLUG308

Type TPLUG408 Type TSLUG20

T-Studs GO-145AStuds mount to breaker or adapter kit. All 800-3000 ampere studs can be rotated foreither vertical or horizontal bus connection. 4000 ampere studs are vertical bus only.Product number includes one stud.Circuit Breaker Max Front BackEnvelope Size Rating Connected Breaker Connected Breaker List

(Amperes) (Amperes) Product Number Product Number Price

800 800 TP08FCA4 $82.00

1600 1600 TP16FCA4 $113.00

20005 2000 TP20FCA4 $113.00

3000 2000 TS20FCA4 TS20BCA4,6 $113.00

3000 2500 TS25FCA6 TS25BCA6 $119.00

3000 3000 TS30FCA7 7,8 $418.00

4000 4000 TS40FCA7 $562.00

4000 4000 TS40LFCA7,9 $789.00

4Aluminum5Small envelope 2000-ampere Power Break6Six T-studs supplied at no charge when ordered with breaker.7Copper8Supplied with integral "T" stud9Extra long stud. Alternate with TS40FCA to maintain proper spacing.

Type TP08FCA Type TP16FCA

Page 54: GE 2005 Buylog - Section 5: Insulated Case Circuit Breakers · 2015. 2. 2. · Prices and data subject to change without notice 5-2 BuyLog Catalog 5 INSULATED CASE CIRCUIT BREAKERS

Prices and data subject to change without notice

5-54 BuyLog Catalog www.geelectrical.com

5

INSU

LATE

DCA

SECI

RCUI

TBR

EAKE

RS

Rev. 12/04

Insulated Case Circuit Breakers

General Purpose Wall and Floor Mounted Enclosures—800 and 1600 ampere enclosures are UL Listed for service

entrance use for single-phase, three-wire or three-phase, four-wire, 600 Vac maximum systems.

—NEMA 1 construction.—Enclosures for 800- and 1600-ampere envelope sizes are supplied

with studs that support circuit breaker in correct position for easymounting. Enclosure, circuit breaker, and neutral must be orderedseparately and are shipped unassembled.

—Enclosures for floor mounted 3000-ampere envelope size areshipped with circuit breaker and neutral already installed.Enclosure and circuit breaker must be ordered separately.

—Enclosure product number includes lugs.—Suitable for use on 65 kA (max) rms symmetrical systems.—Aluminum bus straps and mechanical lugs are included on floor

mounted enclosures.

Power Break EnclosuresField

Circuit InstalledBreaker Max. List Neutral List

Envelope Size Ampere Price, Product Price,(Amperes) Rating MagneTrip MicroVersaTrip2 GO-134 Number GO-149

Wall Mounted800 800 – TPB800 $5137.00 TNT800 $384.00

1600 1600 TPB1600 TPB1600 $5334.00 TNT1600 $437.00

Floor Mounted 3,4

3000 1600 TS1600N TSS1600N $8117.00 – –3000 2000 TS2000N TSS2000N $8617.00 – –3000 2500 TS2500N TSS2500N $10576.00 – –

1Add "E" suffix for motor operated breakers.2For single-phase, 3-wire or 3-phase, 4-wire systems with internal ground fault

protection, appropriate neutral CT must be ordered with circuit breaker from page 5-46.

3Enclosure may be floor or wall mounted.4Order by product number on standard order entry form DE-135, including any

factory-installed breaker accessories. Fax order to Plainville Assembly Center at (860) 747-7032. Enclosure outline drawing is 75C325345SH1.

Enclosure Product Number1

(Includes Lugs)

TPB800

Power Break I Circuit BreakersEnclosures

FAS TeamYour source for factory authorized repair and modernization servicesfor Power Break.

Look to us for:—Genuine GE factory parts—Accessory installations—Direct factory replacement breakers—Test certification—Rentals and loaners

Repairs are performed by GE’s Factory Authorized Service Team,and 24-hour emergency service is available.

For service on your Power Break breakers, contact your local salesoffice, or visit us at www.gepower.com

800A Envelope 2000A Envelope

3000A Envelope 4000A Envelope