gkw railway cables

77
Caledonian Railway Cables www.caledonian-cables.co.uk www.addison-cables.com TRACTION CABLES & HIGH TEMPERATURE CABLES FOR RAILWAY APPLICATION

Upload: may-zheng

Post on 26-Mar-2016

238 views

Category:

Documents


2 download

DESCRIPTION

Caledonian Cables Ltd specialise in the manufacture of a wide range of cables.including Industrial Cables,NEK606 Offshore & Marine Cables,Railway Cables,coax cable,microphone cable,telephone cable

TRANSCRIPT

Page 1: GKW Railway cables

Caledonian Railway Cables

www.caledonian-cables.co.uk www.addison-cables.com

TRACTION CABLES & HIGH TEMPERATURECABLES FOR RAILWAY APPLICATION

Page 2: GKW Railway cables

Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China. Caledonian products are sold in more than 35 countries around the globe.

Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.

Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.

Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets to serve the growing outsourcing needs of both multinational and regional customers.

Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for communication, power and electronics in its 2 plants in UK and 5 plants in China. Caledonian products are sold in more than 35 countries around the globe.

Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.

Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.

Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian has established an extensive network of design, manufacturing, and logistics facilities in the world's major markets to serve the growing outsourcing needs of both multinational and regional customers.

www.caledonian-cables.co.uk www.addison-cables.com

ww

w.caledonian-cables.co.uk

COMPANY PROFILE

Page 3: GKW Railway cables

GKW-RW 300/500V Thin Wall Single Core …………………………………………………………… 1

GKW-RW/S 300/500V Thin Wall Multicore …………………………………………………………… 3

GKW-RW/S EMC 300/500V Thin Wall Screened Multicore ………………………………………… 7

3GKW-RW 0.6/1KV Thin Wall Single Core ………………………………………………………… 10

3GKW-RW/S 0.6/1KV Thin Wall Multicore ………………………………………………………… 12

3GKW-RW/S EMC 0.6/1KV Thin Wall Screened Multicore ……………………………………… 14

3GKW-MW 0.6/1KV Medium Wall Single Core …………………………………………………… 16

3GKW-MW EMC 0.6/1KV Medium Wall Screened Single Core ………………………………… 18

3GKW-MW/S 0.6/1KV Medium Wall Multicore ……………………………………………………… 20

3GKW-MW/S EMC 0.6/1KV Medium Wall Screened Multicore …………………………………… 24

3GKW-DW 0.6/1KV Dual Wall Single Core ………………………………………………………… 28

3GKW-DW/S 0.6/1KV Dual Wall Multicore ………………………………………………………… 30

3GKW-DW/S EMC 0.6/1KV Dual Wall Screened Multicore ……………………………………… 32

4GKW-AXplus-DW 1.8/3KV Dual Wall Single Core ………………………………………………… 36

4GKW-AXplus-DW EMC 1.8/3KV Dual Wall Screened Single Core …………………………… 38

4GKW-AXplus-DW/S EMC 1.8/3KV Dual Wall Screened Multicore ……………………………… 40

TRACTION CABLES FOR RAILWAY APPLICATION

CONTENT

Caledonian Railway Cables

Page 4: GKW Railway cables

www.caledonian-cables.co.uk

9GKW-AXplus-DW 3.6/6KV Dual Wall Single Core ………………………………………………… 42

9GKW-AXplus-DW EMC 3.6/6KV Dual Wall Screened Single Core …………………………… 44

GKW-RW FE180 300/500V Thin Wall Single Core ………………………………………………… 46

3GKW-MW FE180 0.6/1KV Medium Wall Single Core …………………………………………… 48

4GKW-AXplus-DW FE180 1.8/3KV Dual Wall Single Core ……………………………………… 50

HIGH TEMPERATURE CABLES FOR RAILWAY APPLICATION

ORDERING INFORMATION

FRA 145 Single Core ………………………………………………………………………………… 52

FRA 145/S Multicore …………………………………………………………………………………… 54

FRA 145/S EMC Screened Multicore ………………………………………………………………… 59

FRA 155 Single Core ………………………………………………………………………………… 63

FRA 155S Oil Resistant Single Core ………………………………………………………………… 65

FRA 155/S Multicore …………………………………………………………………………………… 67

FRA 155/S EMC Screened Multicore ………………………………………………………………… 69

Ordering Information For GKW Cables ……………………………………………………………… 71

Ordering Information For High Temperature Cables ……………………………………………… 72

Page 5: GKW Railway cables

Caledonian Railway Cables

1TRACTION CABLES

Caledonian Railway Cables

1

TRACTION CABLES

TRACTION CABLESTRACTION CABLES

GKW-RW 300/500V Thin Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

TRACTION CABLES

Page 6: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

2

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

1×0.5 16/0.20 0.18 1.3 61×0.75 24/0.20 0.18 1.56 91×1.0 32/0.20 0.18 1.7 121×1.5 30/0.25 0.22 2.04 171×2.5 50/0.25 0.28 2.66 27

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Soldering HeatResistant

Cold Resistant

Page 7: GKW Railway cables

Caledonian Railway Cables

3

TRACTION CABLES

TRACTION CABLES

GKW-RW/S 300/500V Thin Wall Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation

Page 8: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

4

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×0.5 16/0.20 0.18 4.5 293×0.5 16/0.20 0.18 4.6 364×0.5 16/0.20 0.18 5.0 445×0.5 16/0.20 0.18 5.4 526×0.5 16/0.20 0.18 5.9 597×0.5 16/0.20 0.18 6.4 718×0.5 16/0.20 0.18 6.8 819×0.5 16/0.20 0.18 7.1 81

10×0.5 16/0.20 0.18 7.3 8812×0.5 16/0.20 0.18 7.5 10114×0.5 16/0.20 0.18 7.9 11516×0.5 16/0.20 0.18 8.3 12818×0.5 16/0.20 0.18 8.8 14419×0.5 16/0.20 0.18 8.8 14820×0.5 16/0.20 0.18 9.3 16124×0.5 16/0.20 0.18 10.2 18127×0.5 16/0.20 0.18 10.6 20036×0.5 16/0.20 0.18 11.9 26148×0.5 16/0.20 0.18 13.5 3372×0.75 24/0.20 0.18 4.8 373×0.75 24/0.20 0.18 5.1 484×0.75 24/0.20 0.18 5.6 585×0.75 24/0.20 0.18 6.1 696×0.75 24/0.20 0.18 6.7 817×0.75 24/0.20 0.18 7.1 938×0.75 24/0.20 0.18 7.7 1089×0.75 24/0.20 0.18 8.1 108

10×0.75 24/0.20 0.18 8.3 11812×0.75 24/0.20 0.18 8.6 13714×0.75 24/0.20 0.18 9.0 15616×0.75 24/0.20 0.18 9.5 17518×0.75 24/0.20 0.18 10.0 19819×0.75 24/0.20 0.18 10.1 20220×0.75 24/0.20 0.18 10.5 21924×0.75 24/0.20 0.18 11.7 24827×0.75 24/0.20 0.18 12.2 27536×0.75 24/0.20 0.18 13.7 36248×0.75 24/0.20 0.18 15.5 4682×1.0 32/0.20 0.18 5.2 453×1.0 32/0.20 0.18 5.5 594×1.0 32/0.20 0.18 6.2 73

Page 9: GKW Railway cables

Caledonian Railway Cables

5

TRACTION CABLES

TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

5×1.0 32/0.20 0.18 6.7 876×1.0 32/0.20 0.18 7.3 1027×1.0 32/0.20 0.18 7.9 1198×1.0 32/0.20 0.18 8.4 1359×1.0 32/0.20 0.18 8.9 137

10×1.0 32/0.20 0.18 9.1 15012×1.0 32/0.20 0.18 9.4 17414×1.0 32/0.20 0.18 9.9 19916×1.0 32/0.20 0.18 10.4 22318×1.0 32/0.20 0.18 11.0 25419×1.0 32/0.20 0.18 11.1 25920×1.0 32/0.20 0.18 11.7 28224×1.0 32/0.20 0.18 12.9 31927×1.0 32/0.20 0.18 13.4 35436×1.0 32/0.20 0.18 15.1 46748×1.0 32/0.20 0.18 17.2 6072×1.5 30/0.25 0.22 6.0 593×1.5 30/0.25 0.22 6.4 814×1.5 30/0.25 0.22 7.1 995×1.5 30/0.25 0.22 7.7 1236×1.5 30/0.25 0.22 8.5 1437×1.5 30/0.25 0.22 9.1 1638×1.5 30/0.25 0.22 9.8 1889×1.5 30/0.25 0.22 10.5 189

10×1.5 30/0.25 0.22 10.7 21512×1.5 30/0.25 0.22 11.1 24414×1.5 30/0.25 0.22 11.7 27916×1.5 30/0.25 0.22 12.3 32618×1.5 30/0.25 0.22 13.0 35819×1.5 30/0.25 0.22 13.1 36620×1.5 30/0.25 0.22 13.7 39624×1.5 30/0.25 0.22 15.3 45027×1.5 30/0.25 0.22 15.9 50136×1.5 30/0.25 0.22 17.9 66337×1.5 30/0.25 0.22 18.5 71948×1.5 30/0.25 0.22 20.5 8642×2.5 50/0.25 0.28 7.1 893×2.5 50/0.25 0.28 7.4 1174×2.5 50/0.25 0.28 8.3 1505×2.5 50/0.25 0.28 9.1 1826×2.5 50/0.25 0.28 9.9 2097×2.5 50/0.25 0.28 10.8 2468×2.5 50/0.25 0.28 11.7 2859×2.5 50/0.25 0.28 12.5 286

Page 10: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

6

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

10×2.5 50/0.25 0.28 12.7 31812×2.5 50/0.25 0.28 13.1 37214×2.5 50/0.25 0.28 13.9 42816×2.5 50/0.25 0.28 14.7 48318×2.5 50/0.25 0.28 15.2 53819×2.5 50/0.25 0.28 15.5 56520×2.5 50/0.25 0.28 16.4 61224×2.5 50/0.25 0.28 18.3 69527×2.5 50/0.25 0.28 18.9 77636×2.5 50/0.25 0.28 21.3 103048×2.5 50/0.25 0.28 24.5 1347

Soldering HeatResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant AbrasionResistant

Corona Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant Low TemperatureResistant

Page 11: GKW Railway cables

Caledonian Railway Cables

7

TRACTION CABLES

TRACTION CABLES

GKW-RW/S EMC 300/500V Thin Wall Screened Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Copper Wire Screen

Electron Beam Crosslinkable LSZH Insulation

Page 12: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

8

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×0.5 16/0.20 0.18 4.8 313×0.5 16/0.20 0.18 5.0 434×0.5 16/0.20 0.18 5.4 505×0.5 16/0.20 0.18 6.1 586×0.5 16/0.20 0.18 6.5 777×0.5 16/0.20 0.18 7.0 818×0.5 16/0.20 0.18 7.4 919×0.5 16/0.20 0.18 7.7 93

10×0.5 16/0.20 0.18 7.7 9712×0.5 16/0.20 0.18 8.1 11314×0.5 16/0.20 0.18 8.5 12616×0.5 16/0.20 0.18 8.7 14018×0.5 16/0.20 0.18 9.4 15622×0.5 16/0.20 0.18 10.3 19224×0.5 16/0.20 0.18 10.6 19827×0.5 16/0.20 0.18 11.1 23836×0.5 16/0.20 0.18 12.3 28248×0.5 16/0.20 0.18 13.9 362

2×2×0.5 16/0.20 0.18 7.1 893×2×0.5 16/0.20 0.18 7.5 1034×2×0.5 16/0.20 0.18 8.2 1302×0.75 24/0.20 0.18 5.3 463×0.75 24/0.20 0.18 5.6 554×0.75 24/0.20 0.18 6.2 635×0.75 24/0.20 0.18 6.7 776×0.75 24/0.20 0.18 7.4 907×0.75 24/0.20 0.18 7.7 1038×0.75 24/0.20 0.18 8.3 1209×0.75 24/0.20 0.18 8.7 122

10×0.75 24/0.20 0.18 8.7 12912×0.75 24/0.20 0.18 9.3 14914×0.75 24/0.20 0.18 9.6 16816×0.75 24/0.20 0.18 9.8 18718×0.75 24/0.20 0.18 10.7 21322×0.75 24/0.20 0.18 11.7 25924×0.75 24/0.20 0.18 12.1 26927×0.75 24/0.20 0.18 12.6 29736×0.75 24/0.20 0.18 14.1 387

2×2×0.75 24/0.20 0.18 8.0 1006×2×0.75 24/0.20 0.18 11.6 202

2×1.0 32/0.20 0.18 5.9 633×1.0 32/0.20 0.18 6.2 754×1.0 32/0.20 0.18 6.8 895×1.0 32/0.20 0.18 7.3 108

Page 13: GKW Railway cables

Caledonian Railway Cables

9

TRACTION CABLES

TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

6×1.0 32/0.20 0.18 7.9 1147×1.0 32/0.20 0.18 8.5 1298×1.0 32/0.20 0.18 9.0 1469×1.0 32/0.20 0.18 9.5 15210×1.0 32/0.20 0.18 9.5 16112×1.0 32/0.20 0.18 10.0 20924×1.0 32/0.20 0.18 13.3 34227×1.0 32/0.20 0.18 13.8 37836×1.0 32/0.20 0.18 15.7 515

2×2×1.0 32/0.20 0.18 8.9 1162×1.5 30/0.25 0.22 6.7 803×1.5 30/0.25 0.22 7.1 984×1.5 30/0.25 0.22 7.6 1185×1.5 30/0.25 0.22 8.3 1276×1.5 30/0.25 0.22 9.1 1517×1.5 30/0.25 0.22 9.7 1758×1.5 30/0.25 0.22 10.4 2019×1.5 30/0.25 0.22 11.1 211

10×1.5 30/0.25 0.22 11.1 22512×1.5 30/0.25 0.22 11.7 28524×1.5 30/0.25 0.22 15.9 49927×1.5 30/0.25 0.22 16.5 55236×1.5 30/0.25 0.22 18.5 7202×2.5 50/0.25 0.28 7.7 983×2.5 50/0.25 0.28 8.1 1204×2.5 50/0.25 0.28 8.9 1505×2.5 50/0.25 0.28 9.7 1856×1.5 50/0.25 0.28 10.5 2207×2.5 50/0.25 0.28 11.4 2618×2.5 50/0.25 0.28 12.3 2999×2.5 50/0.25 0.28 13.1 30910×2.5 50/0.25 0.28 13.1 33112×2.5 50/0.25 0.28 13.7 38624×2.5 50/0.25 0.28 18.9 75527×2.5 50/0.25 0.28 19.5 83736×2.5 50/0.25 0.28 21.9 1100

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 14: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

10

3GKW-RW 0.6/1KV Thin Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.6 0.75 1 1.2 1.5 2.0 2.5 3 4.0AWG 20 18 16 14 12Maximum Conductor Resistance Ω/km 40.1 31.1 26.7 20.0 15.5 13.7 10.5 8.21 6.56 5.09Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

Page 15: GKW Railway cables

Caledonian Railway Cables

11

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×0.5 19/0.18 16/0.20 0.3 1.40 61×0.6 19/0.20 0.3 1.50 7

1×0.75 19/0.22 24/0.20 0.3 1.60 8.31×1.0 19/0.25 32/0.20 0.3 1.75 111×1.2 19/0.29 0.3 2.00 131×1.5 19/0.31 30/0.25 0.3 2.15 161×2.0 37/0.25 0.4 2.40 191×2.5 19/0.40 50/0.25 0.4 2.75 261×4 56/0.30 0.4 3.35 40

Highly Flexible UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant

Acid and AlkaliResistant

Soldering HeatResistant

Cold Resistant

Page 16: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

12

3GKW-RW/S 0.6/1KV Thin Wall Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation

Page 17: GKW Railway cables

Caledonian Railway Cables

13

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×0.5 19/0.18 16/0.20 0.3 4.4 293×0.5 19/0.18 16/0.20 0.3 4.6 364×0.5 19/0.18 16/0.20 0.3 5.0 445×0.5 19/0.18 16/0.20 0.3 5.5 526×0.5 19/0.18 16/0.20 0.3 6.0 62

2×2×0.5 19/0.18 16/0.20 0.3 6.5 584×2×0.5 19/0.18 16/0.20 0.3 8.7 992×0.75 19/0.22 24/0.20 0.3 4.75 353×0.75 19/0.22 24/0.20 0.3 5.2 484×0.75 19/0.22 24/0.20 0.3 5.6 586×0.75 19/0.22 24/0.20 0.3 6.75 83

2×2×0.75 19/0.22 24/0.20 0.3 7.75 812×1.0 19/0.25 32/0.20 0.3 5.1 453×1.0 19/0.25 32/0.20 0.3 5.4 544×1.0 19/0.25 32/0.20 0.3 5.8 646×1.0 19/0.25 32/0.20 0.3 7.3 98

10×1.0 19/0.25 32/0.20 0.3 8.7 15025×1.0 19/0.25 32/0.20 0.3 12.8 3242×1.5 19/0.31 30/0.25 0.3 6.0 633×1.5 19/0.31 30/0.25 0.3 6.3 764×1.5 19/0.31 30/0.25 0.3 6.9 945×1.5 19/0.31 30/0.25 0.3 7.8 1206×1.5 19/0.31 30/0.25 0.3 8.5 1417G1.5 19/0.31 30/0.25 0.3 9.1 1658×1.5 19/0.31 30/0.25 0.3 10.3 201

10×1.5 19/0.31 30/0.25 0.3 10.6 21618×1.5 19/0.31 30/0.25 0.3 13.4 35825G1.5 19/0.31 30/0.25 0.3 15.5 4942×2.5 19/0.40 50/0.25 0.4 7.3 983×2.5 19/0.40 50/0.25 0.4 7.8 1224×2.5 19/0.40 50/0.25 0.4 8.7 1475×2.5 19/0.40 50/0.25 0.4 9.4 1806×2.5 19/0.40 50/0.25 0.4 10.6 223

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 18: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

14

3GKW-RW/S EMC 0.6/1KV Thin Wall Screened Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Copper Wire Screen

Electron Beam Crosslinkable LSZH Insulation

Page 19: GKW Railway cables

Caledonian Railway Cables

15

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×0.5 19/0.18 16/0.20 0.3 4.8 423×0.5 19/0.18 16/0.20 0.3 5.3 514×0.5 19/0.18 16/0.20 0.3 5.4 566×0.5 19/0.18 16/0.20 0.3 6.5 82

15×0.5 19/0.18 16/0.20 0.3 9.0 1672×2×0.5 19/0.18 16/0.20 0.3 7.2 803×2×0.5 19/0.18 16/0.20 0.3 8.1 984×2×0.5 19/0.18 16/0.20 0.3 9.3 131

12×2×0.5 19/0.18 16/0.20 0.3 13.0 2762×0.75 19/0.22 24/0.20 0.3 5.0 484×0.75 19/0.22 24/0.20 0.3 6.0 726×0.75 19/0.22 24/0.20 0.3 7.2 103

10×0.75 19/0.22 24/0.20 0.3 8.7 15218×0.75 19/0.22 24/0.20 0.3 11.0 244

3×2×0.75 19/0.22 24/0.20 0.3 9.0 1272×1.0 19/0.25 32/0.20 0.3 5.6 603×1.0 19/0.25 32/0.20 0.3 6.0 764×1.0 19/0.25 32/0.20 0.3 6.5 886×1.0 19/0.25 32/0.20 0.3 7.8 1148×1.0 19/0.25 32/0.20 0.3 8.9 171

25×1.0 19/0.25 32/0.20 0.3 13.8 3922×2×1.0 19/0.25 32/0.20 0.3 8.3 117

2×1.5 19/0.31 30/0.25 0.3 6.5 863×1.5 19/0.31 30/0.25 0.3 6.8 954×1.5 19/0.31 30/0.25 0.3 7.4 1186×1.5 19/0.31 30/0.25 0.3 9.0 168

18×1.5 19/0.31 30/0.25 0.3 14.4 4522×2.5 19/0.40 50/0.25 0.4 7.8 1226×2.5 19/0.40 50/0.25 0.4 11.4 268

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 20: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

16

3GKW-MW 0.6/1KV Medium Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16 25 35Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565Voltage Rating KV 0.6/1

Nominal Conductor Cross Section mm² 50 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.393 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

Page 21: GKW Railway cables

Caledonian Railway Cables

17

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×0.5 19/0.18 16/0.20 0.5 2.0 81×0.75 24/0.20 0.5 2.2 111×1.0 32/0.20 0.55 2.45 141×1.5 30/0.25 0.55 2.7 201×2.5 50/0.25 0.6 3.3 311×4 56/0.30 0.65 3.95 451×6 84/0.30 0.7 4.7 69

1×10 80/0.40 0.8 5.85 1131×16 119/0.41 126/0.40 0.9 7.3 1561×25 182/0.41 196/0.40 1.0 8.9 2501×35 266/0.41 276/0.40 1.1 10.2 3301×50 378/0.41 396/0.40 1.2 11.9 5001×70 348/0.51 360/0.50 1.3 14.3 6901×95 444/0.51 475/0.50 1.4 15.9 883

1×120 551/0.51 608/0.50 1.5 17.9 11801×150 722/0.51 756/0.50 1.6 20.3 14601×185 874/0.51 925/0.50 1.7 22.0 17801×240 1147/0.51 1221/0.50 1.9 25.2 22201×300 1443/0.51 1525/0.50 2.0 28.0 30001×400 2016/0.51 2013/0.50 2.2 33.8 4000

Highly Flexible UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant

Acid and AlkaliResistant

Soldering HeatResistant

Cold Resistant

Page 22: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

18

3GKW-MW EMC 0.6/1KV Medium Wall Screened Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors : C i rcu la r C lass 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating KV 0.6/1

Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

Electron Beam Crosslinkable LSZH Sheath

Copper Wire Screen

Page 23: GKW Railway cables

Caledonian Railway Cables

19

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×0.5 19/0.18 16/0.20 0.5 4.0 261×0.75 24/0.20 0.5 4.2 301×1.0 32/0.20 0.55 4.5 341×1.5 30/0.25 0.55 4.8 431×2.5 50/0.25 0.6 5.5 611×4 56/0.30 0.65 6.15 841×6 84/0.30 0.7 7.0 112

1×10 80/0.40 0.8 8.4 1701×16 119/0.41 126/0.40 0.9 10.2 2501×25 182/0.41 196/0.40 1.0 12.2 3601×35 266/0.41 276/0.40 1.1 13.7 4901×50 378/0.41 396/0.40 1.2 15.7 6901×70 348/0.51 360/0.50 1.3 18.7 9201×95 444/0.51 475/0.50 1.4 20.5 1170

1×120 551/0.51 608/0.50 1.5 22.7 14301×150 722/0.51 756/0.50 1.6 25.5 18301×185 874/0.51 925/0.50 1.7 27.6 2190

高柔软 抗紫外线

NF C32-070-2.2(C1)IEC 60332-3/EN50266

阻燃(成束)

Zero

无卤IEC 60754-1/NF C20-454

EN 50267-2-1

耐冲击

阻燃(单根)NF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

低腐蚀性 低毒 低烟IEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902防矿物油

耐臭氧

耐酸碱腐蚀

耐焊接热耐冷

Page 24: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

20

3GKW-MW/S 0.6/1KV Medium Wall Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5 4.0 6.0 10 16 25 35Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation

Page 25: GKW Railway cables

Caledonian Railway Cables

21

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×0.5 19/0.18 16/0.20 0.5 5.9 393×0.5 19/0.18 16/0.20 0.5 6.1 504×0.5 19/0.18 16/0.20 0.5 7.0 555×0.5 19/0.18 16/0.20 0.5 7.3 746×0.5 19/0.18 16/0.20 0.5 7.5 857×0.5 19/0.18 16/0.20 0.5 9.1 998×0.5 19/0.18 16/0.20 0.5 9.3 1119×0.5 19/0.18 16/0.20 0.5 9.5 114

10×0.5 19/0.18 16/0.20 0.5 9.5 12212×0.5 19/0.18 16/0.20 0.5 10.0 14514×0.5 19/0.18 16/0.20 0.5 10.5 16316×0.5 19/0.18 16/0.20 0.5 11.2 18518×0.5 19/0.18 16/0.20 0.5 12.7 20520×0.5 19/0.18 16/0.20 0.5 13.0 23324×0.5 19/0.18 16/0.20 0.5 13.9 26427×0.5 19/0.18 16/0.20 0.5 14.5 29536×0.5 19/0.18 16/0.20 0.5 16.3 38648×0.5 19/0.18 16/0.20 0.5 19.0 5162×0.75 19/0.21 24/0.20 0.5 6.0 493×0.75 19/0.21 24/0.20 0.5 6.8 634×0.75 19/0.21 24/0.20 0.5 6.9 775×0.75 19/0.21 24/0.20 0.5 8.4 966×0.75 19/0.21 24/0.20 0.5 8.7 1077×0.75 19/0.21 24/0.20 0.5 9.1 1318×0.75 19/0.21 24/0.20 0.5 10.9 1479×0.75 19/0.21 24/0.20 0.5 11.3 15210×0.75 19/0.21 24/0.20 0.5 11.6 16212×0.75 19/0.21 24/0.20 0.5 11.9 17514×0.75 19/0.21 24/0.20 0.5 12.1 21316×0.75 19/0.21 24/0.20 0.5 12.4 24120×0.75 19/0.21 24/0.20 0.5 15.2 32524×0.75 19/0.21 24/0.20 0.5 15.6 34927×0.75 19/0.21 24/0.20 0.5 16.1 38536×0.75 19/0.21 24/0.20 0.5 18.1 50548×0.75 19/0.21 24/0.20 0.5 21.2 6782×1.0 32/0.20 0.55 6.4 593×1.0 32/0.20 0.55 6.8 784×1.0 32/0.20 0.55 7.4 935×1.0 32/0.20 0.55 8.3 1156×1.0 32/0.20 0.55 10.0 1307×1.0 32/0.20 0.55 10.3 1588×1.0 32/0.20 0.55 10.7 1819×1.0 32/0.20 0.55 12.5 20010×1.0 32/0.20 0.55 12.7 21012×1.0 32/0.20 0.55 12.9 234

Page 26: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

22

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

14×1.0 32/0.20 0.55 13.2 26516×1.0 32/0.20 0.55 13.5 30020×1.0 32/0.20 0.55 14.7 37724×1.0 32/0.20 0.55 16.9 43325×1.0 32/0.20 0.55 18.7 51927×1.0 32/0.20 0.55 19.0 60036×1.0 32/0.20 0.55 19.9 64448×1.0 32/0.20 0.55 22.9 8372×1.5 30/0.25 0.55 7.5 753×1.5 30/0.25 0.55 8.0 964×1.5 30/0.25 0.55 8.3 1205×1.5 30/0.25 0.55 10.2 1466×1.5 30/0.25 0.55 11.6 1737×1.5 30/0.25 0.55 12.1 1858×1.5 30/0.25 0.55 12.5 2079×1.5 30/0.25 0.55 12.9 21010×1.5 30/0.25 0.55 13.3 23612×1.5 30/0.25 0.55 14.2 30514×1.5 30/0.25 0.55 14.6 34616×1.5 30/0.25 0.55 15.0 39320×1.5 30/0.25 0.55 16.5 50024×1.5 30/0.25 0.55 19.1 58227×1.5 30/0.25 0.55 19.7 64436×1.5 30/0.25 0.55 23.0 90548×1.5 30/0.25 0.55 25.7 11202×2.5 50/0.25 0.6 8.5 1153×2.5 50/0.25 0.6 8.9 1494×2.5 50/0.25 0.6 9.9 1835×2.5 50/0.25 0.6 11.1 2286×2.5 50/0.25 0.6 12.1 2657×2.5 50/0.25 0.6 13.0 3098×2.5 50/0.25 0.6 14.3 3609×2.5 50/0.25 0.6 15.4 36610×2.5 50/0.25 0.6 15.1 40012×2.5 50/0.25 0.6 15.9 46714×2.5 50/0.25 0.6 16.5 53216×2.5 50/0.25 0.6 17.5 60020×2.5 50/0.25 0.6 20.1 77724×2.5 50/0.25 0.6 21.4 87327×2.5 50/0.25 0.6 22.5 972

2×4 56/0.30 0.65 9.5 1513×4 56/0.30 0.65 10.2 2074×4 56/0.30 0.65 11.3 2615×4 56/0.30 0.65 12.6 3246×4 56/0.30 0.65 13.9 3797×4 56/0.30 0.65 15.2 4338×4 56/0.30 0.65 16.3 5189×4 56/0.30 0.65 17.5 550

Page 27: GKW Railway cables

Caledonian Railway Cables

23

TRACTION CABLES

TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

10×4 56/0.30 0.65 17.7 58112×4 56/0.30 0.65 18.3 67514×4 56/0.30 0.65 19.2 78516×4 56/0.30 0.65 20.4 88620×4 56/0.30 0.65 23.0 112924×4 56/0.30 0.65 24.7 127627×4 56/0.30 0.65 26.1 14352×6 84/0.30 0.7 10.7 2053×6 84/0.30 0.7 11.4 2794×6 84/0.30 0.7 12.6 3535×6 84/0.30 0.7 14.0 4366×6 84/0.30 0.7 15.7 5017×6 84/0.30 0.7 17.2 5972×10 80/0.40 0.8 12.8 3133×10 80/0.40 0.8 13.7 4334×10 80/0.40 0.8 15.4 5145×10 80/0.40 0.8 17.0 6416×10 80/0.40 0.8 19.1 7947×10 80/0.40 0.8 20.7 9192×16 119/0.40 126/0.40 0.9 16.5 4823×16 119/0.40 126/0.40 0.9 17.6 5904×16 119/0.40 126/0.40 0.9 19.8 7875×16 119/0.40 126/0.40 0.9 22.1 9926×16 119/0.40 126/0.40 0.9 24.3 11927×16 119/0.40 126/0.40 0.9 26.5 14092×25 182/0.40 196/0.40 1.0 19.9 7163×25 182/0.40 196/0.40 1.0 21.4 8994×25 182/0.40 196/0.40 1.0 23.8 11825×25 182/0.40 196/0.40 1.0 26.4 14826×25 182/0.40 196/0.40 1.0 29.9 18187×25 182/0.40 196/0.40 1.0 32.1 21282×35 266/0.40 276/0.40 1.1 22.3 7753×35 266/0.40 276/0.40 1.1 24.0 9384×35 266/0.40 276/0.40 1.1 26.7 12305×35 266/0.40 276/0.40 1.1 29.6 15436×35 266/0.40 276/0.40 1.1 33.3 18907×35 266/0.40 276/0.40 1.1 36.7 2263

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 28: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

24

3GKW-MW/S EMC 0.6/1KV Medium Wall Screened Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Copper Wire Screen

Electron Beam Crosslinkable LSZH Insulation

Page 29: GKW Railway cables

Caledonian Railway Cables

25

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×0.5 19/0.18 16/0.20 0.5 6.6 683×0.5 19/0.18 16/0.20 0.5 6.9 754×0.5 19/0.18 16/0.20 0.5 7.5 815×0.5 19/0.18 16/0.20 0.5 8.2 936×0.5 19/0.18 16/0.20 0.5 8.8 1117×0.5 19/0.18 16/0.20 0.5 9.8 1258×0.5 19/0.18 16/0.20 0.5 10.3 1439×0.5 19/0.18 16/0.20 0.5 10.8 149

10×0.5 19/0.18 16/0.20 0.5 11.0 15412×0.5 19/0.18 16/0.20 0.5 12.3 17514×0.5 19/0.18 16/0.20 0.5 13.0 19815×0.5 19/0.18 16/0.20 0.5 13.4 21016×0.5 19/0.18 16/0.20 0.5 13.7 22320×0.5 19/0.18 16/0.20 0.5 14.0 27424×0.5 19/0.18 16/0.20 0.5 14.2 31027×0.5 19/0.18 16/0.20 0.5 14.5 343

9×2×0.5 19/0.18 16/0.20 0.5 20.6 5402×0.75 19/0.21 24/0.20 0.5 7.2 803×0.75 19/0.21 24/0.20 0.5 7.5 904×0.75 19/0.21 24/0.20 0.5 8.3 1165×0.75 19/0.21 24/0.20 0.5 9.1 1336×0.75 19/0.21 24/0.20 0.5 9.9 1657×0.75 19/0.21 24/0.20 0.5 10.7 1868×0.75 19/0.21 24/0.20 0.5 11.5 1949×0.75 19/0.21 24/0.20 0.5 12.3 220

10×0.75 19/0.21 24/0.20 0.5 12.6 25012×0.75 19/0.21 24/0.20 0.5 13.2 27814×0.75 19/0.21 24/0.20 0.5 13.8 30016×0.75 19/0.21 24/0.20 0.5 14.4 34820×0.75 19/0.21 24/0.20 0.5 14.5 35424×0.75 19/0.21 24/0.20 0.5 15.6 40127×0.75 19/0.21 24/0.20 0.5 16.3 459

5×2×0.75 19/0.21 24/0.20 0.5 16.0 3502×1.0 32/0.20 0.55 7.4 933×1.0 32/0.20 0.55 8.1 1144×1.0 32/0.20 0.55 8.8 1405×1.0 32/0.20 0.55 9.8 1586×1.0 32/0.20 0.55 10.8 1707×1.0 32/0.20 0.55 11.8 1898×1.0 32/0.20 0.55 11.8 2199×1.0 32/0.20 0.55 12.0 223

10×1.0 32/0.20 0.55 12.2 234

Page 30: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

26

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

12×1.0 32/0.20 0.55 12.5 26814×1.0 32/0.20 0.55 13.2 30516×1.0 32/0.20 0.55 13.9 33920×1.0 32/0.20 0.55 15.6 43024×1.0 32/0.20 0.55 17.1 51127×1.0 32/0.20 0.55 17.7 5602×1.5 30/0.25 0.55 8.1 1143×1.5 30/0.25 0.55 8.6 1244×1.5 30/0.25 0.55 9.9 1395×1.5 30/0.25 0.55 10.9 1506×1.5 30/0.25 0.55 11.7 1737×1.5 30/0.25 0.55 13.2 2038×1.5 30/0.25 0.55 14.6 2439×1.5 30/0.25 0.55 14.9 274

10×1.5 30/0.25 0.55 15.5 29912×1.5 30/0.25 0.55 16.2 34214×1.5 30/0.25 0.55 16.8 39016×1.5 30/0.25 0.55 17.5 56020×1.5 30/0.25 0.55 17.6 61424×1.5 30/0.25 0.55 19.3 67027×1.5 30/0.25 0.55 19.9 734

6×2×1.5 30/0.25 0.55 18.9 5402×2.5 50/0.25 0.6 9.6 1603×2.5 50/0.25 0.6 10.5 2004×2.5 50/0.25 0.6 11.3 2205×2.5 50/0.25 0.6 12.7 2506×2.5 50/0.25 0.6 13.7 3457×2.5 50/0.25 0.6 14.8 4008×2.5 50/0.25 0.6 14.9 4109×2.5 50/0.25 0.6 16.0 437

10×2.5 50/0.25 0.6 16.0 46112×2.5 50/0.25 0.6 16.8 53114×2.5 50/0.25 0.6 17.7 60116×2.5 50/0.25 0.6 19.0 69120×2.5 50/0.25 0.6 23.3 96924×2.5 50/0.25 0.6 23.5 100427×2.5 50/0.25 0.6 24.0 1104

2×4 56/0.30 0.65 10.8 2163×4 56/0.30 0.65 11.8 2604×4 56/0.30 0.65 13.3 3455×4 56/0.30 0.65 14.7 4405×4 56/0.30 0.65 14.7 4605×4 56/0.30 0.65 15.7 4855×4 56/0.30 0.65 17.2 5845×4 56/0.30 0.65 18.3 605

Page 31: GKW Railway cables

Caledonian Railway Cables

27

TRACTION CABLES

TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

5×4 56/0.30 0.65 18.3 64112×4 56/0.30 0.65 19.5 7602×6 84/0.30 0.7 12.1 2913×6 84/0.30 0.7 13.8 3704×6 84/0.30 0.7 16.3 4585×6 84/0.30 0.7 17.4 6206×6 84/0.30 0.7 17.4 6407×6 84/0.30 0.7 17.8 6738×6 84/0.30 0.7 19.4 7749×6 84/0.30 0.7 20.7 820

10×6 84/0.30 0.7 20.7 87512×6 84/0.30 0.7 21.8 10262×10 80/0.40 0.8 14.3 4323×10 80/0.40 0.8 17.1 5804×10 80/0.40 0.8 19.2 7505×10 80/0.40 0.8 21.1 8506×10 80/0.40 0.8 21.9 8757×10 80/0.40 0.8 22.8 10198×10 80/0.40 0.8 23.7 11902×16 119/0.40 126/0.40 0.9 18.2 6603×16 119/0.40 126/0.40 0.9 20.5 8204×16 119/0.40 126/0.40 0.9 20.4 8745×16 119/0.40 126/0.40 0.9 22.7 10836×16 119/0.40 126/0.40 0.9 24.9 12947×16 119/0.40 126/0.40 0.9 27.1 15218×16 119/0.40 126/0.40 0.9 29.6 18082×25 182/0.40 196/0.40 1.0 22.9 9903×25 182/0.40 196/0.40 1.0 24.4 10754×25 182/0.40 196/0.40 1.0 25.2 14045×25 182/0.40 196/0.40 1.0 27.0 17503×35 266/0.40 276/0.40 1.1 27.9 16006×35 266/0.40 276/0.40 1.1 39.7 33502×50 378/0.40 396/0.40 1.2 29.8 1760

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 32: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

28

3GKW-DW 0.6/1KV Dual Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.6 0.75 1 1.2 1.5 2.0 2.5 3 4.0AWG 20 18 16 14 12Maximum Conductor Resistance Ω/km 40.1 31.1 26.7 20.0 15.5 13.7 10.5 8.21 6.56 5.09Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation2

Electron Beam Crosslinkable LSZH Insulation1

Page 33: GKW Railway cables

Caledonian Railway Cables

29

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×0.5 19/0.18 16/0.20 0.2 1.3 5.51×0.6 19/0.20 0.2 1.39 6.5

1×0.75 19/0.22 24/0.20 0.2 1.52 81×1.0 19/0.25 32/0.20 0.2 1.67 101×1.2 19/0.28 0.2 1.83 121×1.5 19/0.31 30/0.25 0.3 2.04 151×2.0 37/0.25 0.3 2.29 191×2.5 19/0.40 50/0.25 0.3 2.54 241×3 37/0.32 0.3 2.78 291×4 56/0.30 0.4 3.21 39

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 34: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

30

3GKW-DW/S 0.6/1KV Dual Wall Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation2

Electron Beam Crosslinkable LSZH Insulation1

Soldering HeatResistant

Low TemperatureResistant

Highly FlexibleNF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire RetardantImpact Resistant Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low CorrosivityCold Resistant

Page 35: GKW Railway cables

Caledonian Railway Cables

31

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×0.5 19/0.18 16/0.20 0.2 4.0 243×0.5 19/0.18 16/0.20 0.2 4.2 305×0.5 19/0.18 16/0.20 0.2 5.0 436×0.5 19/0.18 16/0.20 0.2 5.4 519×0.5 19/0.18 16/0.20 0.2 6.7 6412×0.5 19/0.18 16/0.20 0.2 6.9 8916×0.5 19/0.18 16/0.20 0.2 7.8 11525×0.5 19/0.18 16/0.20 0.2 9.5 17030×0.5 19/0.18 16/0.20 0.2 10.1 204

2×2×0.5 19/0.18 16/0.20 0.2 5.8 502×0.75 19/0.22 24/0.20 0.2 4.4 324×0.75 19/0.22 24/0.20 0.2 5.0 499×0.75 19/0.22 24/0.20 0.2 7.7 10614×0.75 19/0.22 24/0.20 0.2 8.4 14027×0.75 19/0.22 24/0.20 0.2 11.3 26836×0.75 19/0.22 24/0.20 0.2 12.8 360

3×1.0 19/0.25 32/0.20 0.2 5.0 454×1.0 19/0.25 32/0.20 0.2 5.5 606×1.0 19/0.25 32/0.20 0.2 6.6 8812×1.0 19/0.25 32/0.20 0.2 8.6 16014×1.0 19/0.25 32/0.20 0.2 9.1 17420×1.0 19/0.25 32/0.20 0.2 11.2 25550×1.0 19/0.25 32/0.20 0.2 16.8 6202×1.5 37/0.22 30/0.25 0.3 5.4 555×1.5 37/0.22 30/0.25 0.3 7.1 1107×1.5 37/0.22 30/0.25 0.3 8.4 15010×1.5 37/0.22 30/0.25 0.3 9.9 17016×1.5 37/0.22 30/0.25 0.3 11.7 31018×1.5 37/0.22 30/0.25 0.3 12.4 35024×1.5 37/0.22 30/0.25 0.3 14.4 45030×1.5 37/0.22 30/0.25 0.3 15.6 56050×1.5 37/0.22 30/0.25 0.3 20.1 8683×2.5 37/0.29 50/0.25 0.3 7.0 1056×2.5 37/0.29 50/0.25 0.3 9.6 20012×2.5 37/0.29 50/0.25 0.3 12.6 36018×2.5 37/0.29 50/0.25 0.3 15.3 54524×2.5 37/0.29 50/0.25 0.3 17.8 69527×2.5 37/0.29 50/0.25 0.3 18.2 78030×2.5 37/0.29 50/0.25 0.3 19.3 87036×2.5 37/0.29 50/0.25 0.3 21.0 1050

UV ResistantIRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

AbrasionResistant

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Page 36: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

32

3GKW-DW/S EMC 0.6/1KV Dual Wall Screened Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 88.5 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation2Copper Wire Screen

Electron Beam Crosslinkable LSZH Insulation1

Page 37: GKW Railway cables

Caledonian Railway Cables

33

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×2×0.25 19/0.13 0.2 5.7 483×2×0.25 19/0.13 0.2 6.1 574×2×0.25 19/0.13 0.2 7.0 727×2×0.25 19/0.13 0.2 7.8 9225×0.25 19/0.13 0.2 8.9 1392×0.5 19/0.18 16/0.20 0.2 4.3 343×0.5 19/0.18 16/0.20 0.2 4.5 404×0.5 19/0.18 16/0.20 0.2 4.8 475×0.5 19/0.18 16/0.20 0.2 5.4 586×0.5 19/0.18 16/0.20 0.2 5.9 707×0.5 19/0.18 16/0.20 0.2 6.3 808×0.5 19/0.18 16/0.20 0.2 6.8 869×0.5 19/0.18 16/0.20 0.2 7.2 95

10×0.5 19/0.18 16/0.20 0.2 7.2 10112×0.5 19/0.18 16/0.20 0.2 7.4 11015×0.5 19/0.18 16/0.20 0.2 8.5 13516×0.5 19/0.18 16/0.20 0.2 8.5 14218×0.5 19/0.18 16/0.20 0.2 8.9 16220×0.5 19/0.18 16/0.20 0.2 9.3 18322×0.5 19/0.18 16/0.20 0.2 9.9 19525×0.5 19/0.18 16/0.20 0.2 10.3 21327×0.5 19/0.18 16/0.20 0.2 10.5 23130×0.5 19/0.18 16/0.20 0.2 11.3 26536×0.5 19/0.18 16/0.20 0.2 12.1 30142×0.5 19/0.18 16/0.20 0.2 12.9 35948×0.5 19/0.18 16/0.20 0.2 13.6 41050×0.5 19/0.18 16/0.20 0.2 14.2 430

2×2×0.5 19/0.18 16/0.20 0.2 6.4 693×2×0.5 19/0.18 16/0.20 0.2 6.7 804×2×0.5 19/0.18 16/0.20 0.2 7.4 955×2×0.5 19/0.18 16/0.20 0.2 9.2 1366×2×0.5 19/0.18 16/0.20 0.2 9.2 1488×2×0.5 19/0.18 16/0.20 0.2 9.7 155

10×2×0.5 19/0.18 16/0.20 0.2 10.9 20012×2×0.5 19/0.18 16/0.20 0.2 12.1 23915×2×0.5 19/0.18 16/0.20 0.2 13.0 30016×2×0.5 19/0.18 16/0.20 0.2 13.0 32020×2×0.5 19/0.18 16/0.20 0.2 14.4 3602×3×0.5 19/0.18 16/0.20 0.2 7.3 902×0.75 19/0.22 24/0.20 0.2 4.8 403×0.75 19/0.22 24/0.20 0.2 5.0 504×0.75 19/0.22 24/0.20 0.2 5.5 62

Page 38: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

34

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

5×0.75 19/0.22 24/0.20 0.2 6.1 756×0.75 19/0.22 24/0.20 0.2 6.6 857×0.75 19/0.22 24/0.20 0.2 7.2 1008×0.75 19/0.22 24/0.20 0.2 7.7 113

10×0.75 19/0.22 24/0.20 0.2 8.1 13012×0.75 19/0.22 24/0.20 0.2 8.4 15014×0.75 19/0.22 24/0.20 0.2 9.1 16916×0.75 19/0.22 24/0.20 0.2 9.7 20618×0.75 19/0.22 24/0.20 0.2 10.1 23020×0.75 19/0.22 24/0.20 0.2 11.1 25624×0.75 19/0.22 24/0.20 0.2 12.0 29425×0.75 19/0.22 24/0.20 0.2 12.3 300

2×2×0.75 19/0.22 24/0.20 0.2 7.1 853×2×0.75 19/0.22 24/0.20 0.2 7.6 1094×2×0.75 19/0.22 24/0.20 0.2 9.9 1435×2×0.75 19/0.22 24/0.20 0.2 10.7 1826×2×0.75 19/0.22 24/0.20 0.2 11.9 2267×2×0.75 19/0.22 24/0.20 0.2 13.2 2798×2×0.75 19/0.22 24/0.20 0.2 13.4 291

10×2×0.75 19/0.22 24/0.20 0.2 14.8 3333×3×0.75 19/0.22 24/0.20 0.2 8.9 1515×4×0.75 19/0.22 24/0.20 0.2 12.8 288

2×1.0 19/0.25 32/0.20 0.2 5.0 503×1.0 19/0.25 32/0.20 0.2 5.5 604×1.0 19/0.25 32/0.20 0.2 5.8 725×1.0 19/0.25 32/0.20 0.2 6.6 886×1.0 19/0.25 32/0.20 0.2 7.3 1147×1.0 19/0.25 32/0.20 0.2 7.9 1338×1.0 19/0.25 32/0.20 0.2 8.5 1509×1.0 19/0.25 32/0.20 0.2 8.9 160

10×1.0 19/0.25 32/0.20 0.2 8.9 16812×1.0 19/0.25 32/0.20 0.2 9.2 18816×1.0 19/0.25 32/0.20 0.2 10.5 25018×1.0 19/0.25 32/0.20 0.2 11.2 27525×1.0 19/0.25 32/0.20 0.2 12.7 35527×1.0 19/0.25 32/0.20 0.2 13.3 39530×1.0 19/0.25 32/0.20 0.2 13.8 45036×1.0 19/0.25 32/0.20 0.2 15.1 53042×1.0 19/0.25 32/0.20 0.2 16.3 60450×1.0 19/0.25 32/0.20 0.2 17.8 690

2×2×1.0 19/0.25 32/0.20 0.2 7.8 1074×2×1.0 19/0.25 32/0.20 0.2 9.4 1286×2×1.0 19/0.25 32/0.20 0.2 11.6 239

12×2×1.0 19/0.25 32/0.20 0.2 14.3 400

Page 39: GKW Railway cables

Caledonian Railway Cables

35

TRACTION CABLES

TRACTION CABLES

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

4×3×1.0 19/0.25 32/0.20 0.2 11.5 2303×4×1.0 19/0.25 32/0.20 0.2 11.3 2454×4×1.0 19/0.25 32/0.20 0.2 12.5 265

2×1.5 37/0.22 30/0.25 0.3 5.8 703×1.5 37/0.22 30/0.25 0.3 6.1 814×1.5 37/0.22 30/0.25 0.3 6.7 1005×1.5 37/0.22 30/0.25 0.3 7.7 1346×1.5 37/0.22 30/0.25 0.3 8.3 1537×1.5 37/0.22 30/0.25 0.3 9.1 1848×1.5 37/0.22 30/0.25 0.3 10.3 2229×1.5 37/0.22 30/0.25 0.3 10.5 234

10×1.5 37/0.22 30/0.25 0.3 10.5 24012×1.5 37/0.22 30/0.25 0.3 10.9 26816×1.5 37/0.22 30/0.25 0.3 12.5 36418×1.5 37/0.22 30/0.25 0.3 13.2 40525×1.5 37/0.22 30/0.25 0.3 15.8 56248×1.5 37/0.22 30/0.25 0.3 20.7 988

2×2×1.5 37/0.22 30/0.25 0.3 9.2 1533×2×1.5 37/0.22 30/0.25 0.3 9.8 2057×2×1.5 37/0.22 30/0.25 0.3 12.6 330

2×2.5 37/0.29 50/0.25 0.3 7.0 1053×2.5 37/0.29 50/0.25 0.3 7.6 1304×2.5 37/0.29 50/0.25 0.3 8.4 1705×2.5 37/0.29 50/0.25 0.3 9.4 1906×2.5 37/0.29 50/0.25 0.3 10.3 2257×2.5 37/0.29 50/0.25 0.3 11.4 2708×2.5 37/0.29 50/0.25 0.3 12.6 343

10×2.5 37/0.29 50/0.25 0.3 13.2 37012×2.5 37/0.29 50/0.25 0.3 13.6 42016×2.5 37/0.29 50/0.25 0.3 15.6 56018×2.5 37/0.29 50/0.25 0.3 16.6 62025×2.5 37/0.29 50/0.25 0.3 19.3 83427×2.5 37/0.29 50/0.25 0.3 20.5 87048×2.5 37/0.29 50/0.25 0.3 25.6 1560

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 40: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

36

4GKW-AXplus-DW 1.8/3KV Dual Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3.0

Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 1.8/3.0

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (for flexible installation)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation2

Electron Beam Crosslinkable LSZH Insulation1

Page 41: GKW Railway cables

Caledonian Railway Cables

37

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.0 32/0.20 0.7 2.8 171×1.5 30/0.25 0.8 3.2 231×2.0 37/0.26 0.8 3.55 281×2.5 50/0.25 0.9 3.75 341×4.0 56/0.30 1.0 4.5 531×6.0 84/0.30 1.1 5.1 741×10 80/0.40 1.2 6.35 1181×16 119/0.41 126/0.40 1.5 8.3 1801×25 182/0.41 196/0.40 1.8 10.2 2741×35 266/0.41 276/0.40 2.0 11.7 3791×50 378/0.41 396/0.40 2.2 13.6 5501×70 348/0.51 360/0.50 2.1 15.6 7301×95 444/0.51 475/0.50 2.3 17.3 940

1×120 551/0.51 608/0.50 2.4 19.6 11801×150 722/0.51 756/0.50 2.6 21.9 15101×185 874/0.51 925/0.50 2.8 23.8 18021×240 1147/0.51 1221/0.50 2.9 26.9 22901×300 1443/0.51 1525/0.50 3.0 29.7 29281×400 2016/0.51 2013/0.50 3.4 35.8 4040

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 42: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

38

4GKW-AXplus-DW EMC 1.8/3KV Dual Wall Screened Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3

Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 1.8/3

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation2Electron Beam Crosslinkable LSZH Insulation1

Electron Beam Crosslinkable LSZH SheathCopper Wire Screen

Page 43: GKW Railway cables

Caledonian Railway Cables

39

TRACTION CABLES

TRACTION CABLES

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.0 32/0.20 0.7 4.6 381×1.5 30/0.25 0.8 5.2 471×2.5 50/0.25 0.9 5.8 631×4 56/0.30 1.0 6.7 891×6 84/0.30 1.1 7.4 1231×10 80/0.40 1.2 9.0 1781×16 119/0.41 126/0.40 1.5 11.2 2801×25 182/0.41 196/0.40 1.8 13.4 3711×35 266/0.41 276/0.40 2.0 14.8 4921×50 378/0.41 396/0.40 2.2 16.8 6931×70 348/0.51 360/0.50 2.1 19.0 9131×95 444/0.51 475/0.50 2.3 20.7 11601×120 551/0.51 608/0.50 2.4 23.4 14411×150 722/0.51 756/0.50 2.6 25.9 17301×185 874/0.52 925/0.50 2.8 27.8 20881×240 1147/0.51 1221/0.50 2.9 31.2 29081×300 1443/0.51 1525/0.50 3.0 34.2 33751×400 1887/0.50 2013/0.50 3.4 37.1 4250

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 44: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

40

4GKW-AXplus-DW/S EMC 1.8/3KV Dual Wall Screened Multicore

º Applications

Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 10 16 25 35Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 1.95 1.24 0.795 0.565Voltage Rating KV 1.8/3

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

Electron Beam Crosslinkable LSZH Insulation2Copper Wire Screen

Electron Beam Crosslinkable LSZH Insulation1

Page 45: GKW Railway cables

Caledonian Railway Cables

41

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional

AreaNo.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

2×1.5 30/0.25 0.8 9.2 1353×1.5 30/0.25 0.8 10.0 1646×1.5 30/0.25 0.8 13.8 3153×2.5 50/0.25 0.9 11.4 2254×4 56/0.30 1.0 15.4 427

3×10 80/0.40 1.2 18.2 6483×16 119/0.40 126/0.40 1.5 23.1 9003×25 182/0.40 196/0.40 1.8 28.4 15204×25 182/0.40 196/0.40 1.8 34.1 18692×35 266/0.40 276/0.40 2.0 29.8 15803×35 266/0.40 276/0.40 2.0 31.6 19704×35 266/0.40 276/0.40 2.0 37.0 2102

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 46: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

42

9GKW-AXplus-DW 3.6/6KV Dual Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 3.6/6

Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 3.6/6

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation2

Electron Beam Crosslinkable LSZH Insulation1

Page 47: GKW Railway cables

Caledonian Railway Cables

43

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.5 30/0.25 1.3 4.4 341×2.5 50/0.25 1.4 4.9 471×4 56/0.30 1.5 5.7 681×6 84/0.30 1.5 6.3 88

1×10 80/0.40 1.5 7.5 1401×16 119/0.41 126/0.40 1.7 9.4 2051×25 182/0.41 196/0.40 1.8 11.0 2971×35 266/0.41 276/0.40 2.0 12.5 4101×50 378/0.41 396/0.40 2.3 14.5 5701×70 348/0.51 360/0.50 2.2 16.5 7601×95 444/0.51 475/0.50 2.5 18.5 980

1×120 551/0.51 608/0.50 2.7 20.8 12361×150 722/0.51 756/0.50 2.8 23.1 15701×185 874/0.51 925/0.50 3.0 25.0 18481×240 1147/0.51 1221/0.50 3.1 28.0 24001×300 1443/0.51 1525/0.50 3.1 30.9 29701×400 2016/0.51 2013/0.50 3.3 36.5 4090

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 48: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

44

9GKW-AXplus-DW EMC 3.6/6KV Dual Wall Screened Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation1: Electron beam crosslinkable LSZH compound.• Insulation2: Electron beam crosslinkable LSZH compound.• Screen: Copper wire screen.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 3.6/6

Nominal Conductor Cross Section mm² 70 95 120 150 185 240 300 400Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654 0.0495Voltage Rating KV 3.6/6

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation2Electron Beam Crosslinkable LSZH Insulation1

Electron Beam Crosslinkable LSZH SheathCopper Wire Screen

Page 49: GKW Railway cables

Caledonian Railway Cables

45

TRACTION CABLES

TRACTION CABLES

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 8xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.5 30/0.25 1.3 6.6 721×2.5 50/0.25 1.4 7.2 891×4 56/0.30 1.5 8.2 1191×6 84/0.30 1.5 9.1 150

1×10 80/0.40 1.5 10.4 2201×16 119/0.41 126/0.40 1.7 12.4 3301×25 182/0.41 196/0.40 1.8 14.3 3901×35 266/0.41 276/0.40 2.0 15.7 5501×50 378/0.41 396/0.40 2.3 17.7 7331×70 348/0.51 360/0.50 2.2 20.0 9701×95 444/0.51 475/0.50 2.5 22.0 12161×120 551/0.51 608/0.50 2.7 24.7 15101×150 722/0.51 756/0.50 2.8 27.1 19001×185 874/0.51 925/0.50 3.0 29.1 21951×240 1147/0.51 1221/0.50 3.1 32.3 28301×300 1443/0.51 1525/0.50 3.1 35.6 35201×400 2016/0.51 2013/0.50 3.3 38.3 4364

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

IRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Cold Resistant

Page 50: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

46

GKW-RW FE180 300/500V Thin Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

MICA Tape

Page 51: GKW Railway cables

Caledonian Railway Cables

47

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×0.5 19/0.18 16/0.20 0.3 2.00 81×0.75 19/0.21 24/0.20 0.3 2.25 101×1.0 32/0.20 0.35 2.50 141×1.5 30/0.25 0.35 2.80 181×2.5 50/0.25 0.35 3.20 29

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Soldering HeatResistant

Cold Resistant

V

FE

InsulationIntegrity FE180

EN 50200/IEC 60331/NF C32-070-2.3(CR1)

Page 52: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

48

3GKW-MW FE180 0.6/1KV Medium Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating KV 0.6/1

Nominal Conductor Cross Section mm² 25 35 50 70 95 150Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.132Voltage Rating KV 0.6/1

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -40℃ ~+120℃ (Static); -35℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Insulation

MICA Tape

Page 53: GKW Railway cables

Caledonian Railway Cables

49

TRACTION CABLES

TRACTION CABLES

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.0 32/0.20 0.55 3.15 191×1.5 30/0.25 0.55 3.40 241×2.5 50/0.25 0.60 4.05 36.61×4 56/0.30 0.65 4.60 52.51×6 84/0.30 0.70 5.30 731×10 80/0.40 0.80 6.35 1221×16 119/0.41 126/0.40 0.90 8.15 1821×25 182/0.41 196/0.40 1.0 9.65 2631×35 266/0.41 276/0.40 1.1 10.80 3651×50 378/0.41 396/0.40 1.2 12.80 5301×70 348/0.51 360/0.50 1.3 15.10 7301×95 444/0.51 475/0.50 1.4 17.00 930

1×150 722/0.51 756/0.50 1.6 21.30 1450

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant Acid and AlkaliResistant

Soldering HeatResistant

Cold Resistant

V

FE

InsulationIntegrity FE180

EN 50200/IEC 60331/NF C32-070-2.3(CR1)

Page 54: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

50

4GKW-AXplus-DW FE180 1.8/3KV Dual Wall Single Core

º Applications

Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.

º Standard

• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0

º Construction

• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Flame Barrier: MICA tape.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 1.5 2.5 4.0 6.0 10 16 25 35 50Maximum Conductor Resistance Ω/km 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393Voltage Rating KV 1.8/3.0

Nominal Conductor Cross Section mm² 70 95 120 150 185 240Maximum Conductor Resistance Ω/km 0.277 0.21 0.164 0.132 0.108 0.0817Voltage Rating KV 1.8/3.0

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable LSZH Sheath

MICA Tape

Electron Beam Crosslinkable LSZH Insulation

Page 55: GKW Railway cables

Caledonian Railway Cables

51

TRACTION CABLES

TRACTION CABLES

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter of Strands

No/mm

Nominal Insulation Thickness

mm

Nominal Overall

Diametermm

Nominal Weightkg/km

1×1.5 30/0.25 1.05 4.90 381×2.5 50/0.25 1.15 5.35 501×4 56/0.30 1.25 6.10 881×6 84/0.30 1.30 7.00 93

1×10 80/0.40 1.30 8.10 1421×16 119/0.41 126/0.40 1.15 9.30 2101×25 182/0.41 196/0.40 1.50 10.8 2901×35 266/0.41 276/0.40 1.50 12.1 4001×50 378/0.41 396/0.40 1.60 13.8 5611×70 348/0.51 360/0.50 1.70 16.2 7601×95 444/0.51 475/0.50 1.90 18.0 980

1×120 551/0.51 608/0.50 1.60 20.2 12121×150 722/0.51 756/0.50 2.20 22.7 15201×185 874/0.51 925/0.50 2.40 24.6 18301×240 1147/0.51 1221/0.50 2.50 27.6 2411

Soldering HeatResistant

Low TemperatureResistant

Highly Flexible

UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire RetardantIRM 903 FuelOil Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

AbrasionResistant

Corona ResistantFlame Retardant

NF C32-070-2.1(C2)IEC 60332-1/EN 50265-2-1

EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity

Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

IRM 902 MineralOil Resistant

Ozone Resistant

Acid and AlkaliResistant

Cold Resistant

V

FE

InsulationIntegrity FE180

EN 50200/IEC 60331/NF C32-070-2.3(CR1)

Page 56: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

52

FRA 145 Single Core

º Applications

Single core cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for laying in tubes, surface wiring, direct in plaster or underneath it, as well in conduits.

º Standard

• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070

(non-flamepropagating)• DIN51900(lowfireload)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 85.9 57.2 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)

Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185 240 300Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108 0.0817 0.0654Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable

Polyolefine Copolymer Insulation

Page 57: GKW Railway cables

Caledonian Railway Cables

53

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

1×0.25 19/0.13 0.5 1.5 51×0.34 19/0.16 0.5 1.7 61×0.50 19/0.18 0.5 1.9 81×0.75 24/0.20 0.6 2.2 111×1.0 32/0.20 0.6 2.5 141×1.5 30/0.25 0.6 3.0 211×2.5 48/0.25 0.7 3.7 331×4.0 56/0.30 0.8 4.2 481×6.0 81/0.30 0.9 4.7 67

1×10.0 78/0.40 1.0 6.1 1121×16.0 119/0.40 1.1 7.5 1721×25.0 182/0.40 1.3 9.0 2621×35.0 266/0.40 1.3 10.1 3621×50.0 378/0.40 1.6 12.7 5121×70.0 348/0.50 1.6 14.7 7101×95.0 444/0.50 1.8 16.4 937

1×120.0 551/0.50 1.8 18.2 11591×150.0 722/0.50 1.9 20.9 14471×185.0 874/0.50 2.0 22.9 17901×240.0 1147/0.50 2.2 25.8 23181×300.0 1443/0.50 2.4 28.3 2897

Highly Flexible UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Weather Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

Page 58: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

54

FRA 145/S Multicore

º Applications

Multicore cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.

º Standard

• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070

(non-flamepropagating)• DIN51900(lowfireload)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation: Electronbeamcrosslinkablepolyolefinecopolymer.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)

Nominal Conductor Cross Section mm² 10 16 25 35 50 70 95Maximum Conductor Resistance Ω/km 1.95 1.24 0.795 0.565 0.393 0.277 0.21Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable Polyolefine Copolymer Sheath

Electron Beam Crosslinkable Polyolefine Copolymer Insulation

Page 59: GKW Railway cables

Caledonian Railway Cables

55

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×0.5 19/0.18 0.5 5.1 383G0.5 19/0.18 0.5 5.5 46

4×(G)0.5 19/0.18 0.5 5.9 555G0.5 19/0.18 0.5 6.7 686G0.5 19/0.18 0.5 7.1 777G0.5 19/0.18 0.5 7.8 938G0.5 19/0.18 0.5 8.6 10210G0.5 19/0.18 0.5 9.4 13012G0.5 19/0.18 0.5 9.4 12514G0.5 19/0.18 0.5 10.0 14516G0.5 19/0.18 0.5 10.7 1662×0.75 24/0.20 0.6 5.9 523G0.75 24/0.20 0.6 6.2 61

4×(G)0.75 24/0.20 0.6 6.9 755G0.75 24/0.20 0.6 7.7 946G0.75 24/0.20 0.6 8.3 1077G0.75 24/0.20 0.6 9.1 1278G0.75 24/0.20 0.6 10.2 14410G0.75 24/0.20 0.6 11.1 18614G0.75 24/0.20 0.6 11.7 20316G0.75 24/0.20 0.6 12.5 233

1×1 32/0.20 0.6 3.9 252×1 32/0.20 0.6 6.3 503G1 32/0.20 0.6 6.8 674G1 32/0.20 0.6 7.4 875G1 32/0.20 0.6 8.4 1076G1 32/0.20 0.6 8.9 1247G1 32/0.20 0.6 10.2 1528G1 32/0.20 0.6 11.0 177

10G1 32/0.20 0.6 12.1 22214G1 32/0.20 0.6 12.7 25216G1 32/0.20 0.6 13.6 29019G1 32/0.20 0.6 15.1 33821G1 32/0.20 0.6 16.0 38024G1 32/0.20 0.6 17.1 437

Page 60: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

56

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

25G1 32/0.20 0.6 17.1 46827G1 32/0.20 0.6 17.1 49730G1 32/0.20 0.6 17.7 51433G1 32/0.20 0.6 18.9 58237G1 32/0.20 0.6 20.3 7141×1.5 30/0.25 0.6 4.3 322×1.5 30/0.25 0.6 7.8 893G1.5 30/0.25 0.6 9.1 106

4×(G)1.5 30/0.25 0.6 9.1 1235G1.5 30/0.25 0.6 10.1 1567G1.5 30/0.25 0.6 12.1 22410G1.5 30/0.25 0.6 15.0 31412G1.5 30/0.25 0.6 15.0 34614G1.5 30/0.25 0.6 15.4 36616G1.5 30/0.25 0.6 16.8 41519G1.5 30/0.25 0.6 18.3 48621G1.5 30/0.25 0.6 19.7 56224G1.5 30/0.25 0.6 21.1 64425G1.5 30/0.25 0.6 21.7 69327G1.5 30/0.25 0.6 21.7 73130G1.5 30/0.25 0.6 21.8 76033G1.5 30/0.25 0.6 22.6 83137G1.5 30/0.25 0.6 24.8 10321×2.5 48/0.25 0.7 5.0 452×2.5 48/0.25 0.7 9.1 1023G2.5 48/0.25 0.7 9.9 1454G2.5 48/0.25 0.7 10.9 1895G2.5 48/0.25 0.7 12.2 2356G2.5 48/0.25 0.7 13.2 2887G2.5 48/0.25 0.7 14.6 3448G2.5 48/0.25 0.7 15.7 37910G2.5 48/0.25 0.7 17.7 48212G2.5 48/0.25 0.7 18.7 48314G2.5 48/0.25 0.7 19.0 57216G2.5 48/0.25 0.7 20.1 65119G2.5 48/0.25 0.7 20.7 76521G2.5 48/0.25 0.7 23.7 85724G2.5 48/0.25 0.7 25.8 98425G2.5 48/0.25 0.7 25.8 112127G2.5 48/0.25 0.7 25.8 106930G2.5 48/0.25 0.7 26.7 117533G2.5 48/0.25 0.7 28.0 130137G2.5 48/0.25 0.7 30.6 1599

1×4 56/0.30 0.8 5.6 62

Page 61: GKW Railway cables

Caledonian Railway Cables

57

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×4 56/0.30 0.8 10.2 1613G4 56/0.30 0.8 10.9 2174G4 56/0.30 0.8 12.8 2685G4 56/0.30 0.8 14.2 3346G4 56/0.30 0.8 14.9 3987G4 56/0.30 0.8 16.4 4588G4 56/0.30 0.8 17.6 523

10G4 56/0.30 0.8 20.1 67412G4 56/0.30 0.8 20.1 68814G4 56/0.30 0.8 21.5 8051×6 81/0.30 0.9 6.1 832×6 81/0.30 0.9 11.6 2133G6 81/0.30 0.9 12.4 2794G6 81/0.30 0.9 13.8 3415G6 81/0.30 0.9 15.8 4946G6 81/0.30 0.9 16.7 5197G6 81/0.30 0.9 18.3 6161×10 78/0.40 1.0 7.7 1362×10 78/0.40 1.0 14.7 3513G10 78/0.40 1.0 15.7 4574G10 78/0.40 1.0 17.5 5905G10 78/0.40 1.0 19.6 7466G10 78/0.40 1.0 21.7 8757G10 78/0.40 1.0 23.7 10241×16 119/0.40 1.1 9.1 2042×16 119/0.40 1.1 17.7 5303G16 119/0.40 1.1 19.3 7074G16 119/0.40 1.1 21.5 9195G16 119/0.40 1.1 23.9 11486G16 119/0.40 1.1 26.2 13697G16 119/0.40 1.1 28.9 15691×25 182/0.40 1.3 10.9 3082×25 182/0.40 1.3 21.3 7923G25 182/0.40 1.3 22.7 9774G25 182/0.40 1.3 25.4 12995G25 182/0.40 1.3 28.1 16306G25 182/0.40 1.3 31.1 19647G25 182/0.40 1.3 34.5 23511×35 266/0.40 1.3 12.1 4142×35 266/0.40 1.3 23.7 10503G35 266/0.40 1.3 25.5 13254G35 266/0.40 1.3 28.4 17475G35 266/0.40 1.3 31.3 21731×50 378/0.40 1.6 14.9 589

Page 62: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

58

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×50 378/0.40 1.6 29.3 14713G50 378/0.40 1.6 31.5 31334G50 378/0.40 1.6 35.3 25145G50 378/0.40 1.6 39.1 31331×70 348/0.50 1.6 17.1 8002×70 348/0.50 1.6 33.7 19823G70 348/0.50 1.6 36.4 25854G70 348/0.50 1.6 40.3 33905G70 348/0.50 1.6 44.5 42331×95 444/0.50 1.8 19.2 10542×95 444/0.50 1.8 37.5 25653G95 444/0.50 1.8 40.0 33264G95 444/0.50 1.8 45.3 44515G95 444/0.50 1.8 50.7 5602

Highly Flexible UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Weather Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

Page 63: GKW Railway cables

Caledonian Railway Cables

59

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

FRA 145/S EMC Screened Multicore

º Applications

Multicore cable with improved fire performance and very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.

º Standard

• IEC 60754-1, EN 50267-2-1 (halogen free)• IEC 60754-2, EN 50267-2-2 (no corrosive gases)• NES 02-713, NFC 20-454 (no toxic gases)• IEC 61034, EN 50268-2 (low smoke density)• IEC60332-1,EN50265-2-1(flameretardant)• IEC 60332-3, EN 50266-2, NF C 32-070

(non-flamepropagating)• DIN51900(lowfireload)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295. • Insulation: Electronbeamcrosslinkablepolyolefinecopolymer.• Screen: Copper wire screen.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95Voltage Rating V 300/500V(≤1mm²);450/750V(≥1.5mm²)

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable Polyolefine Copolymer Sheath

Copper Wire Screen

Electron Beam Crosslinkable Polyolefine Copolymer Insulation

Page 64: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

60

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+145℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

1×0.5 19/0.18 0.5 3.7 232×0.5 19/0.18 0.5 5.6 453×0.5 19/0.18 0.5 6.1 594×0.5 19/0.18 0.5 6.7 725×0.5 19/0.18 0.5 7.3 866×0.5 19/0.18 0.5 7.9 1027×0.5 19/0.18 0.5 8.4 1188×0.5 19/0.18 0.5 9.0 13310×0.5 19/0.18 0.5 10.0 15712×0.5 19/0.18 0.5 10.0 1641×0.75 24/0.20 0.6 4.0 282×0.75 24/0.20 0.6 6.7 663×0.75 24/0.20 0.6 7.1 784×0.75 24/0.20 0.6 7.7 945×0.75 24/0.20 0.6 8.5 1136×0.75 24/0.20 0.6 8.9 1327×0.75 24/0.20 0.6 9.9 1588×0.75 24/0.20 0.6 10.6 18110×0.75 24/0.20 0.6 11.5 20912×0.75 24/0.20 0.6 11.5 21914×0.75 24/0.20 0.6 12.2 25116×0.75 24/0.20 0.6 12.9 27919×0.75 24/0.20 0.6 14.5 34721×0.75 24/0.20 0.6 15.3 385

1×1 32/0.20 0.6 4.2 332×1 32/0.20 0.6 7.2 793×1 32/0.20 0.6 7.7 894×1 32/0.20 0.6 8.3 1135×1 32/0.20 0.6 9.0 1346×1 32/0.20 0.6 9.5 1567G1 32/0.20 0.6 10.9 1878×1 32/0.20 0.6 11.4 218

10×1 32/0.20 0.6 12.5 25312×1 32/0.20 0.6 12.5 2661×1.5 30/0.25 0.6 4.8 43

Page 65: GKW Railway cables

Caledonian Railway Cables

61

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×1.5 30/0.25 0.6 8.4 1053×(G)1.5 30/0.25 0.6 8.9 1194×(G)1.5 30/0.25 0.6 9.9 163

5×1.5 30/0.25 0.6 10.7 1836×1.5 30/0.25 0.6 11.5 219

7×(G)1.5 30/0.25 0.6 12.7 2738×1.5 30/0.25 0.6 13.7 30510×1.5 30/0.25 0.6 15.0 30912×1.5 30/0.25 0.6 15.0 37114×1.5 30/0.25 0.6 16.0 45516×1.5 30/0.25 0.6 17.0 50219×1.5 30/0.25 0.6 19.3 62721×1.5 30/0.25 0.6 20.3 69825×1.5 30/0.25 0.6 21.7 7371×2.5 50/0.25 0.7 5.6 612×2.5 50/0.25 0.7 9.9 157

3×(G)2.5 50/0.25 0.7 10.5 1984×2.5 50/0.25 0.7 11.5 236

5×(G)2.5 50/0.25 0.7 12.6 2876×2.5 50/0.25 0.7 13.8 3217G2.5 50/0.25 0.7 15.5 4308×2.5 50/0.25 0.7 16.5 46110×2.5 50/0.25 0.7 18.3 53412×2.5 50/0.25 0.7 18.3 56914×2.5 50/0.25 0.7 19.6 66416×2.5 50/0.25 0.7 20.7 75319×2.5 50/0.25 0.7 23.5 93421×2.5 50/0.25 0.7 24.4 1022

1×4 56/0.30 0.8 6.3 842×4 56/0.30 0.8 10.9 1743×4 56/0.30 0.8 11.5 2264×4 56/0.30 0.8 13.2 3175G4 56/0.30 0.8 14.5 3766×4 56/0.30 0.8 15.6 4367×4 56/0.30 0.8 17.0 5318×4 56/0.30 0.8 18.3 61010×4 56/0.30 0.8 20.7 73612×4 56/0.30 0.8 20.7 79114×4 56/0.30 0.8 22.1 9101×6 81/0.30 0.9 6.9 1092×6 81/0.30 0.9 12.1 2503×6 81/0.30 0.9 12.8 3164×6 81/0.30 0.9 14.3 404

Page 66: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

62

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

5×6 81/0.30 0.9 16.0 5186×6 81/0.30 0.9 17.4 5957×6 81/0.30 0.9 19.3 7161×10 78/0.40 1.0 8.4 1682×10 78/0.40 1.0 15.1 3903G10 78/0.40 1.0 16.4 5294G10 78/0.40 1.0 18.1 6695G10 78/0.40 1.0 20.2 8406G10 78/0.40 1.0 22.3 9737G10 78/0.40 1.0 24.3 1132

Highly Flexible UV Resistant

NF C32-070-2.2(C1)IEC 60332-3/EN50266

Fire Retardant

Weather Resistant

Zero

Zero HalogenIEC 60754-1/NF C20-454

EN 50267-2-1

Impact Resistant

Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453

Low Corrosivity Low Toxicity Low Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073

Page 67: GKW Railway cables

Caledonian Railway Cables

63

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

FRA 155 Single Core

º Applications

Single core cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc.

º Standard

• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.34 0.50 0.75 1.0 1.5 2.5 4.0 6.0 10 16Maximum Conductor Resistance Ω/km 85.9 57.2 40.1 26.7 20.0 13.7 8.21 5.09 3.39 1.95 1.24Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)

Nominal Conductor Cross Section mm² 25 35 50 70 95 120 150 185 240Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.164 0.132 0.108 0.0817Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable

Polyolefine Copolymer Insulation

Page 68: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

64

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

1×0.25 19/0.13 0.5 1.5 41×0.34 19/0.16 0.5 1.6 51×0.50 19/0.18 0.5 1.7 71×0.75 24/0.20 0.6 2.2 101×1.0 32/0.20 0.6 2.6 131×1.5 30/0.25 0.6 2.7 201×2.5 48/0.25 0.7 3.4 311×4.0 56/0.30 0.8 4.1 461×6.0 81/0.30 0.9 5.2 65

1×10.0 78/0.40 1.0 6.4 1101×16.0 119/0.40 1.1 7.6 1651×25.0 182/0.40 1.3 9.2 2501×35.0 266/0.40 1.3 10.6 3451×50.0 378/0.40 1.6 12.3 5501×70.0 348/0.50 1.6 14.6 7801×95.0 444/0.50 1.8 16.3 1010

1×120.0 551/0.50 1.8 18.4 12801×150.0 722/0.50 1.9 20.8 14201×185.0 874/0.50 2.0 22.5 17101×240.0 1147/0.50 2.2 25.7 2250

Highly Flexible UV ResistantNF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

Page 69: GKW Railway cables

Caledonian Railway Cables

65

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

FRA 155S Oil Resistant Single Core

º Applications

Single core cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc.

º Standard

• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Colour Code: Various colours on request.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.50 0.75 1.0 1.5 2.5 4.0 6.0Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21 5.09 3.39Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable

Polyolefine Copolymer Insulation

Page 70: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

66

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

1×0.50 19/0.18 0.4 1.7 71×0.75 24/0.20 0.5 2.2 111×1.0 32/0.20 0.6 2.6 151×1.5 30/0.25 0.6 2.7 191×2.5 48/0.25 0.7 3.5 301×4.0 56/0.30 0.8 4.2 451×6.0 81/0.30 0.9 5.2 66

Oil Resistant Highly Flexible UV ResistantNF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

Page 71: GKW Railway cables

Caledonian Railway Cables

67

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

FRA 155/S Multicore

º Applications

Multicore cable very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.

º Standard

• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Sheath:Electronbeamcrosslinkablepolyolefinecopolymer.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.50 0.75 1.0 1.5 2.5Maximum Conductor Resistance Ω/km 85.9 40.1 26.7 20.0 13.7 8.21Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable Polyolefine Copolymer Sheath

Electron Beam Crosslinkable Polyolefine Copolymer Insulation

Page 72: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

68

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

4×0.25 19/0.13 0.5 5.4 333×0.34 19/0.15 0.5 5.1 282×0.5 19/0.18 0.5 5.2 303×0.5 19/0.18 0.5 5.6 408×0.5 19/0.18 0.5 8.8 10216×0.5 19/0.18 0.5 10.4 1663×0.75 24/0.20 0.6 6.7 594×0.75 24/0.20 0.6 7.5 80

2×1 32/0.20 0.6 7.0 613×1 32/0.20 0.6 7.6 77

2×1.5 30/0.25 0.6 7.5 663×1.5 30/0.25 0.6 7.9 924×1.5 30/0.25 0.6 8.8 1175×1.5 30/0.25 0.6 10.1 1503×2.5 50/0.25 0.7 9.9 1454×2.5 50/0.25 0.7 11.0 1865×2.5 50/0.25 0.7 12.0 2235×1.5 30/0.25 0.6 10.1 1503×2.5 50/0.25 0.7 9.9 1454×2.5 50/0.25 0.7 11.0 1865×2.5 50/0.25 0.7 12.0 223

Highly Flexible UV ResistantNF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

Page 73: GKW Railway cables

Caledonian Railway Cables

69

HIGH TEMPERATURE CABLES

HIGH TEMPERATURE CABLES

FRA 155/S EMC Screened Multicore

º Applications

Multicore cable with very high resistance to temperature designed for internal wiring in lamps, heating appliances and distribution boxes in apparatus, mechanical and plant engineering, etc. Used for fixed and flexible application in dry, humid and wet rooms.

º Standard

• IEC60332-1,EN50265-2-1(flameretardant)• EN50266-2(non-flamepropagating)

º Construction

• Conductors: Class 5 stranded tinned copper to IEC60228/VDE 0295.

• Insulation:Electronbeamcrosslinkablepolyolefinecopolymer.• Screen: Copper wire screen.• Sheath: Electronbeamcrosslinkablepolyolefinecopolymer.

º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.25 0.50 1.5 2.5Maximum Conductor Resistance Ω/km 85.9 40.1 13.7 8.21Voltage Rating V 450/750V(≤0.5mm²);600/1000V(>0.5mm²)

º Mechanical and Thermal Properties

Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -55℃ ~+155℃ (Static); -40℃ ~+120℃ (Flexing)Short Circuit Temperature: +280℃

Stranded Tinned Copper Conductor

Electron Beam Crosslinkable Polyolefine Copolymer Sheath

Copper Wire Screen

Electron Beam Crosslinkable Polyolefine Copolymer Insulation

Page 74: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

70

º Dimensions and Weight

No. of cores& Nominal Conductor Cross Sectional Area

No.×mm²

Number and Nominal Diameter

of StrandsNo/mm

Nominal Insulation Thickness

mm

Nominal Overall Diameter

mmNominal Weight

kg/km

2×0.25 19/0.12 0.5 5.1 346×0.25 19/0.12 0.5 7.0 67

4×2×0.25 19/0.12 0.5 14.0 2774×0.5 19/0.18 0.5 7.6 7616×0.5 19/0.18 0.5 11.6 2063G1.5 30/0.25 0.6 8.7 11910G1.5 30/0.25 0.6 14.7 33216G1.5 30/0.25 0.6 22.0 7408G2.5 50/0.25 0.7 18.0 4989G2.5 50/0.25 0.7 18.6 518

Highly Flexible UV ResistantNF C32-070-2.2(C1)

IEC 60332-3/EN50266

Fire RetardantWeather ResistantImpact Resistant Flame RetardantNF C32-070-2.1(C2)

IEC 60332-1/EN 50265-2-1

Page 75: GKW Railway cables

Caledonian Railway Cables

71

ORDERING INFORMATION

ORDERING INFORMATION

Ordering Information For GKW Cables

º Cable Code Designation

3GKW - W/S EMC

GKW - W FE180

FE180: Fire Resistant CableElectron-beam

Cross-linked Insulation

Cold Resistant

EMC:Screen

Blank: Non Screened

Testing Voltage

/S: Multicore

Blank: Single core

Electron-beam

Cross-linked Insulation

RW: Reduced Wall/Thin Wall

DW: Dual Wall

MW: Medium Wall

Cold Resistant

Heat Resistant

RW: Reduced Wall/Thin Wall

DW: Dual Wall

MW: Medium WallHeat Resistant

Page 76: GKW Railway cables

www.addison-cables.com

www.caledonian-cables.co.uk

72

Ordering Information For High Temperature Cables

º Cable Code Designation

FRA 145/S EMC

EMC: Screen

Blank: Non Screened

/S: Multicore

S: Oil Resistant

Blank: Single Core

145: -55℃ ~+145℃

155: -55℃ ~+155℃

Page 77: GKW Railway cables

UNITED KINGDOMMarchants Industrial Centre,

Mill Lane, Laughton, Lewes,

East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: [email protected]

Website: www.caledonian-cables.co.uk

HONG KONGUnit B 22/F CMA Building

64-66 Connaught Road Central

Hong Kong

Tel: 852-36527508

Fax: 852-35834834

Email: [email protected]

[email protected]

SHANGHAIRoom 3501, CITIC Square, 1168 Nanjing Xi Lu,

Shanghai 200041, P.R. China

Tel: 86-21-51119178

Fax: 86-21-52524616

Email: [email protected]

[email protected]