Halitosis Determination with HaliSens measurement of hydrogen sulfide determins the objective severity of Halitosis concentration range 40 - 1200 ppb very short measurement intervall of 2 minutes PC based intuitive and simple handling visualisation of the treatment and the history ready within 2 minutes after starting the instrument robust and reliable system with short amortisation cycle NEW R

Upload: others

Post on 21-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Halitosis Determination with HaliSens R NEW · HaliSens--Brochure-1e C Specifications subjet to changes! Function Principle and Measurement HaliSens allows a rapid and reliable determination

Halitosis Determination with HaliSens

measurement of hydrogen sulfide determins the objective severity of Halitosis

concentration range 40 - 1200 ppb

very short measurement intervall of 2 minutes

PC based intuitive and simple handling

visualisation of the treatment and the history

ready within 2 minutes after starting the instrument

robust and reliable system with short amortisation cycle

NEW

R

Page 2: Halitosis Determination with HaliSens R NEW · HaliSens--Brochure-1e C Specifications subjet to changes! Function Principle and Measurement HaliSens allows a rapid and reliable determination

Ha

liSens-

-Bro

chu

re-1

eC

Speci

ficatio

ns

subje

t to

changes!

Function Principle and Measurement

HaliSens allows a rapid and reliable determination of the concentration of hydrogen sulfide from 5 ml sample gas volume. Halitosis can be characterized with the detection of hydrogen sulfide which is the most important gas component for the determination of halitosis. So the evaluation of the severity of halitosis can be done with high accuracy. The hydrogen sulfide sensor simultaneously detects additional volatile sulfur components (VSC's), which also contributes to halitosis.

With a sterile syringe a breathing gas sample from the oral cavity is injected into the injection port of the instrument. The measured signal and the concentration in ppb are displayed graphically on the display of the PC in real time.

The integrated patient management allows retrospective consideration and the medical treatment of halitosis can be traced at any time.

TECHNICAL DATA

Weight:

Supply voltage:

PC operating system:

Dimensions (LxWxH):

Concentration range:

Uncertainty:

40-1200 ppb

7%

18x18x10 cm

1.7 kg

230V, 2 W

Windows 7 / 10