haug ionization – for the elimination of electrostatic charges · haug ionization – for the...

2
HAUG Ionization – for the elimination of electrostatic charges Power pack Multistat Plus The high-voltage power pack Multitstat Plus with its long permissible connected length and extended monitoring facilities is a high-performance unit. The Multistat Plus is particularly suited to systems with multiple ionizing bars. The extended functions of the Multistat Plus allow improved monitoring of the ionizing system set-up with this unit. The unit has 6 individually monitored high-voltage sockets. Any overload is indicated by means of a warning lamp and a signal at the signalling socket. All HAUG ionizing units can be connected using the X-2000 high-voltage connector system. The most appropriate HAUG ionizing units can therefore be used depending on the fitting dimensions, the required output and the application conditions. Display The display indicates the high-voltage or currents at the 6 high- voltage connections. The currents are output one after another in a fixed sequence. This allows good monitoring of the ionizing units connected to the HV sockets. Control Overload lamp: indicates an overload at the HV connections. Reset: in the event of failure, the unit will switch off – restart using Reset. HV kV / HV mA: voltage of current indication on display 0 I 0 I II Power HV - mA HV - kV Overload Reset ill.2 ill.3 ill.1 Static Line - Power pack Multistat P lus Multistat Plus II = mA Start I = kV ~ 4 6 8 10 2 0 0 1 2 3 4 5 2,5 X-7966 I II STAT PLUS Power HV - mA HV - kV Overload Reset 0 I 0 I II II= mA I= kV HAUG GmbH & Co. KG Germany Friedrich-List-Str. 18 D-70771 Leinf.-Echterdingen Phone: +49 711 / 94 98-0 Telefax: +49 711 / 94 98-298 www.haug.de E-mail: [email protected] HAUG Biel AG Switzerland Johann-Renfer-Str. 60 CH-2500 Biel-Bienne 6 Phone: +41 32 / 344 96 96 Telefax: +41 32 / 344 96 97 www.haug-ionisation.com E-mail: [email protected]

Upload: others

Post on 28-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HAUG Ionization – for the elimination of electrostatic charges · HAUG Ionization – for the elimination of electrostatic charges Power pack Multistat Plus The high-voltage power

HAUG Ionization –

for the elimination

of electrostatic

charges

Power pack Multistat Plus

The high-voltage power pack Multitstat Plus with its long

permissible connected length and extended monitoring

facilities is a high-performance unit.

The Multistat Plus is particularly suited to systems with multiple

ionizing bars. The extended functions of the Multistat Plus allow

improved monitoring of the ionizing system set-up with this unit.

The unit has 6 individually monitored high-voltage sockets. Any

overload is indicated by means of a warning lamp and a signal

at the signalling socket.

All HAUG ionizing units can be connected using the X-2000

high-voltage connector system. The most appropriate HAUG

ionizing units can therefore be used depending on the fitting

dimensions, the required output and the application conditions.

Display

The display indicates the high-voltage or currents at the 6 high-

voltage connections. The currents are output one after another

in a fixed sequence.

This allows good monitoring of the ionizing units connected to

the HV sockets.

Control

Overload lamp: indicates an overload at the HV connections.

Reset: in the event of failure, the unit will switch off –

restart using Reset.

HV kV / HV mA: voltage of current indication on display

0

I

0I

II

PowerHV - mA

HV - kV

Overload Reset

ill.2

ill.3

ill.1

Sta

tic Lin

e - Pow

er pack M

ultis

tat Plu

s

Multistat Plus

II = mA StartI = kV~

4 68

10

2

0

01

2 34

5

2,5 X-7966

I

II

STATPLU

SPower

HV - mA

HV - kV

Overload

Reset

0I

0

I

I I

II = mA

Start

I = kV~

4

6

8

10

20

01

2

3

4

5

2,5

X-7966

I

II

HAUG GmbH & Co. KG Germany

Friedrich-List-Str. 18

D-70771 Leinf.-Echterdingen

Phone: +49 711 / 94 98-0

Telefax: +49 711 / 94 98-298

www.haug.de

E-mail: [email protected]

HAUG Biel AG Switzerland

Johann-Renfer-Str. 60

CH-2500 Biel-Bienne 6

Phone: +41 32 / 344 96 96

Telefax: +41 32 / 344 96 97

www.haug-ionisation.com

E-mail: [email protected]

0

0

I

III

PLU

S

Page 2: HAUG Ionization – for the elimination of electrostatic charges · HAUG Ionization – for the elimination of electrostatic charges Power pack Multistat Plus The high-voltage power

External

reset

button

Multis

tat Plu

s

Technical data Multistat Plus

Types: (115 V) Order-No.: 01.7863.100

(230 V) 01.7862.100

Protection type: IP 54

Protection class: I

Nominal input voltage: 115 V / 230 V (50 – 60 Hz)

Power input: max. 200 VA

Nominal output voltage: ca. 6 – 8 kV

Load rating of signalling contacts: 24 V / 35 V , max. 50 mA

HV-terminals: 6

Connectable length: max. 6 x 10 m

)

Operating temperature: +5 °C to +45 °C

Storage/transport temperature: -15 °C to +60 °C

Weight: approx. 11 kg

Mains cable: 2.6 m; fixed to the device

Multistat Plus

Multistat Plus Order-No.:

HV output current: 4 mA

per HV socket (permissible operating range)

(ionizing unit incl. HV cable

Subject to technical changes!

, shielded

5 m, incl. round plug Order-No.: 06.8941.000

10 m, incl. round plug Order-No.: 06.8941.001

20 m, incl. round plug Order-No.: 06.8941.002

Order-No.: X-0616

Order-No.: X-5718

AC AC

A

AC

AC DC

I �

Accessories

Signalling cable K1

Round plug

Angled plug

Contact assignment

signalling socket

Pin 1: Signal output overload. In the event of

overload, a signal (approx. 12 V) is output.

Pin 2: Signal output, voltage values for current

monitoring of HV sockets.

Pin 3: Input reset signal. After the unit has

switched off following an overload, it can be

restarted by means of this input.

Pin 4: Signal ground GND.

Pin 5: Floating contact. Contact closed when high

voltage is correct.

Pin 6: Floating contact. Contact closed when high

voltage is correct.

Pin PE: Ground.

D-0

14

8-G

B -

07

/09

V 1.1

PLUS0

I

Signalling socket

14

1

12

3

320

0

0

I

III

ST

AT

PLU

S

PowerHV - mA

HV - kV

Overload Reset

II = mA StartI = kV~

4 68

10

2

0

01

2 34

5

2,5 X-7966

I

II

300

30

0

25

Ø 8.2