website: http://www.americanlimetec.com email: [email protected] telephone: 773.286.0566 LAST REVISED 2010-11-16 COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY. Tradical® Hemcrete® Wall System: Internal Wood Frame with Lime Render Exterior Vapor Permeable Paint (2 Coats) Vapor Permeable Magnesium Board Tape and Mud at Magnesium Board Joint Magnesium Board Fastener 2X4 Wood Stud, 16-24” O.C. Tradical® Hemcrete® (variable thickness to suit required thermal performance) 5/8” Baumit FL68 Lime Render Base Coat 1/8” Pre-colored Baumit SEP02 Lime Render Top Coat Flashing Metal Stop Bead at Bottom Edge of Lime Render Brick Veneer at Exposed Foundation Details are indicative only and need to be made project specific. While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements. HC LR-01 RESIDENTIAL CUT-AWAY WALL SECTION Insulative R-Value* 35.5 Efficiency of Construction (# of Trades) 2 Approximate Wall Thickness 13” Embodied Carbon Dioxide Output in kilograms per square foot -4.1 Recyclable or Biodegradable Content 95% Approximate Cost Per Square Foot $29 * R-value not adjusted for thermal mass. The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.

Upload: limetech

Post on 16-Apr-2017

689 views

Category:

Documents


3 download

TRANSCRIPT

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

Tradical® Hemcrete® Wall System:Internal Wood Frame with Lime Render Exterior

Vapor Permeable Paint (2 Coats)

Vapor Permeable Magnesium Board

Tape and Mud at Magnesium Board Joint

Magnesium Board Fastener

2X4 Wood Stud, 16-24” O.C.

Tradical® Hemcrete® (variable thickness to suit required thermal performance)

5/8” Baumit FL68 Lime Render Base Coat

1/8” Pre-colored Baumit SEP02 Lime Render Top Coat

Flashing

Metal Stop Bead at Bottom Edge of Lime Render

Brick Veneer at Exposed Foundation

Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.

HC LR-01RESIDENTIAL CUT-AWAY WALL SECTION

Insulative R-Value* 35.5

Efficiency of Construction (# of Trades) 2

Approximate Wall Thickness 13”

Embodied Carbon Dioxide Outputin kilograms per square foot

-4.1

Recyclable or Biodegradable Content 95%

Approximate Cost Per Square Foot $29

*R-value not adjusted for thermal mass.

The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

HC LR-02RESIDENTIAL CUT-AWAY WALL SECTION

Tradical® Hemcrete® Wall System:Central Wood Frame with Lime Render Exterior

Vapor Permeable Paint (2 Coats)

1/8” Baumit RK38 or KG30 Interior Lime Plaster Top Coat

3/8” Baumit RK38 Interior Lime Plaster Base Coat

2X4 Wood Stud, 16-24” O.C.

Tradical® Hemcrete® (variable thickness to suit required thermal performance)

5/8” Baumit FL68 Lime Render Base Coat

1/8” Pre-colored Baumit SEP02 Lime Render Top Coat

Flashing

Stop Bead at Bottom Edge of Lime Render

Brick Veneer at Exposed Foundation

Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.

Insulative R-Value* 35.5

Efficiency of Construction (# of Trades) 2

Approximate Wall Thickness 13”

Embodied Carbon Dioxide Outputin kilograms per square foot

-4.1

Recyclable or Biodegradable Content 98%

Approximate Cost Per Square Foot $29

*R-value not adjusted for thermal mass.

The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.

Tradical® Hemcrete® Wall System:Internal Wood Frame with Brick Veneer Exterior

Vapor Permeable Paint (2 Coats)

Vapor Permeable Magnesium Board

Tape and Mud at Magnesium Board Joint

Magnesium Board Fastener

2X4 Wood Stud, 16-24” O.C.

Tradical® Hemcrete® (variable thickness to suit required thermal performance)

2x2 Wood Furring, 16-24” O.C.

Brick Tie

Furring Stop

Air Cavity (ventilated and drained)

Brick Veneer

Mortar Net at Base of Air Cavity

Brick Cavity Vent

Flashing

HC BV-01RESIDENTIAL CUT-AWAY WALL SECTION

Insulative R-Value* 29.9

Efficiency of Construction (# of Trades) 2

Approximate Wall Thickness 18”

Embodied Carbon Dioxide Outputin kilograms per square foot

-2.1

Recyclable or Biodegradable Content 96%

Approximate Cost Per Square Foot $35

*R-value not adjusted for thermal mass.

The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.

website: http://www.americanlimetec.comemail: [email protected]

telephone: 773.286.0566LAST REVISED 2010-11-16

COPYRIGHT 2010 AMERICAN LIME TECHNOLOGY.

HC FC-01RESIDENTIAL CUT-AWAY WALL SECTION

Vapor Permeable Paint (2 Coats)

Vapor Permeable Magnesium Board

Tape and Mud at Magnesium Board Joint

Magnesium Board Fastener

2X4 Wood Stud, 16-24” O.C.

Tradical® Hemcrete® (variable thickness to suit required thermal performance)

2x2 Wood Furring, 16-24” O.C.

1x2 Vertical Wood Furring, 16-24” O.C.

Air Cavity (ventilated and drained)

Furring Stop

Fiber Cement Siding

Insect Mesh at Base of Air Cavity

Brick Veneer at Exposed Foundation Wall

Flashing

Details are indicative only and need to be made project specific.While reasonable care has been taken to ensure that the information included in this drawing was accurate at the time of issue, American Lime Technology reserves the right to change specifications at any time. Final detailing remains the responsibility of the designer due to site and client specific requirements.

Tradical® Hemcrete® Wall System:Internal Wood Frame with Fiber Cement Siding Exterior

Insulative R-Value* 29.9

Efficiency of Construction (# of Trades) 2

Approximate Wall Thickness 14”

Embodied Carbon Dioxide Outputin kilograms per square foot

-3

Recyclable or Biodegradable Content 95%

Approximate Cost Per Square Foot $29

*R-value not adjusted for thermal mass.

The above figures reflect the performance of mid-wall conditions only and do not take into account floor, roof, corner, opening or mechanical conditions.