he transter

Upload: ibnuhary

Post on 08-Jan-2016

15 views

Category:

Documents


1 download

DESCRIPTION

Marine Plate Heat Exchanger

TRANSCRIPT

  • www.tranter.com

    PLATE HEAT EXCHANGERS

    FOR MARINE APPLICATIONS

  • There are times when the reliability of your equipment is crucial!When conditions are tough, crew and equipment are really put to the test. The main engine oil cooler and central freshwater cooler simply have to work. There is no room for compromise when the sea is rough and the harbour far away.

    Thats why Tranter offers you the very best. Reliable, compact, and efficient plate heat exchangers that are easy to service and maintain. So, it's no wonder they can be found on board countless vessels all around the world from luxury yachts to huge container vessels, supertankers and offshore rigs.

    Tranter offers an extensive range of gasketed plate heat ex-changers specially designed for marine applications. This, combined with our extensive experience and solid technical expertise within marine and industrial applications, makes us a reliable partner.

    For many decades our plate heat exchangers have proved to be the perfect solution for various closed-circuit cooling systems at sea. They are also frequently found in other applications on board, such as tap-water production systems and HVAC systems.

  • No unnecessary ballastWhy fill up your engine room with heavy, bulky equipment, when efficiency and economy are vital factors?

    A plate heat exchanger from Tranter is only about 1/3 of the size and 1/6 of the weight of a shell-&-tube exchanger of comparable performance. Even if it seems more reasonable to invest in a tube exchanger, this would have a much higher life cycle cost than a plate heat exchanger.

    One reason is that the heat transfer properties of a plate heat exchanger are 3 to 5 times higher. Another is the close tempe-rature approach which is as low as 1K. Efficiency pays off!

    A plate heat exchanger offers many advantages compared with conventional shell-and-tube exchangers Up to 50% more efficient

    Up to 90% more compact

    3-5 times higher k-values

    Unique turbulent flow design Closer temperature approach as low as 1K

    Far less material less use of exotic alloys or titanium

  • Camshaft Lube Oil Cooler

    Stern Tube Lube

    Oil Cooler

    Sea Water

    High Temp. Fresh Water

    Fresh Water

    Lube Oil Main Engine Lube Oil Cooler

    Central Freshwater Coolers

    Keep cool for smooth and reliable operationCentral cooling systemsA central cooling system consists of central coolers that use sea water to cool a secondary circuit with fresh water. This circuit passes through a battery of other coolers, such as lubrication oil cooler, jacket water cooler, turbo-charging air cooler etc.

    Using fresh water in the secondary circuit, minimizes corro-sion, scaling and redundancy in machines and equipment and ensures smooth operation. At the same time the cost for repair and replacement will be kept to a minimum.

  • Central Freshwater Coolers

    Jacket Water Cooler

    M/E T/C.L.O Cooler

    Central Freshwater Coolers

    Jacket Water Cooler

    Stern Tube Lube Oil Cooler

    Main Engine Lube Oil Cooler

  • 6Our experts will guide you to the right solutionTranter is a global supplier of plate heat exchangers. We have extensive experience of heat transfer solutions for marine, off-shore, HVAC and industrial applications around the world. Our mission is to help you achieve the optimum solution with re-gard to performance efficiency, payback and energy conservation. Our marine programme encompasses plate heat exchangers that fulfil any capacity requirement. Our patented Ultra flex design

    means that we can closely match precise heat exchanger require-ments with just a few plate designs. Plates are provided in stain-less steel, and titanium as standard, but are also available in other materials. We can also offer frames constructed from aluminium etc. when it is important to keep the weight low.

    Quality all the wayAt Tranter we enlist cutting-edge technology in our manu-facturing processes. Raw materials are subject to rigorous quality speci fi cations. Exact measurements and metall urgical analyses are performed in accordance with our Total Quality Management System. Fully-automated plate presses ensure consistent high quality and plate uniformity time after time. After assembly each plate heat exchanger is tested, and the results are incorporated into a data bank. Before packing and shipping, we carry out a final check. Nothing is left to chance!

  • Improve thermal systems efficiency and reliability

    SUPERMAX Shell & Plate HE andPLATECOIL Prime Surface HE Banks

    Plate HEs save energy, space and weightBoth the SUPERMAX Shell & Plate HE and PLATECOIL

    Prime Surface HE Banks are designed for optimum efficiency in compact packages. SUPERMAX exchangers consistently

    outperform shell & tube deck heaters, while PLATECOIL

    Banks make pipe coil obsolete for bulk cargo heating banks and box coolers.

    Both products offer: Much smaller footprints

    Lighter weight

    Easier installation

    Removable heat exchange surfaces for effective cleaning

    Faster heating or cooling with less energy fluid

    Turbulent flow for better scaling resistance, greater reliability

    Less steel, lower purchase price, shorter lead time and less

    expensive delivery

    Topside and below, take advantage of all the benefits plate heat exchangers provide. Contact us today for details on these and other strategies to improve your your offshore thermal systems. Let us put the efficiency and reliability of plate HEs

    to work for you!

    Plate HEs on-board optimise your thermal system efficiency with less - for less.

  • When conditions are tough Take your performance to the max

    Plate HEs performance at S&T pressuresNow you can obtain the thermal efficiency and compactness of plate heat exchangers in elevated pressure/high and low temp-erature applications with Tranter gasketless, all-welded plate heat exchangers. Until recently, heat exchangers in elevated pressure/temperature of corrosive media applications were of-ten shell & tube (S&T) units. This meant constant tradeoffs in thermal efficiency, material mass and excessive physical foot-print, until recently.

    Two complementary lines of Tranter all-welded HEs allow you to take your performance to the max, in less space, and at lower cost than S&T tubular exchangers.

    SUPERMAXMAXCHANGER

  • Box Cooler InSea Chest

  • A Tranter plate heat exchanger consists of very few parts and is very compact. The plates have a unique plate design, called Ultraflex, which enables exact matching for any application. Performance adjustments are easily made by adding or removing plates. It is also possible to achieve both symmetrical and asymmetrical flow and full turbulence in each, thus maximizing the heat transfer efficiency and minimizing fouling.

    When it comes to service, you will discover how quick and easy it is to dismantle the exchangers for inspection, cleaning and maintenance.

    Service and maintenance made easy

    A global service networkOur service network of representatives and engineers in Europe, Asia, Australia, Middle East, North & South America will back you up with support and services. They can also train your staff in handling day-to-day maintenance themselves. You will meet experts who can answer any questions that may arise.

    Contact us for more information.

  • Maintenance of plate heat exchangers

    Tranter has a global network of service centres that offers quick and reliable maintenance of plate and frame heat exchangers of all brands.

    Plates are cleaned by immersion. The washing cycles are carried out according to the type of plate material and the nature of fouling.

    These are the conditions in wich you could find your plate heat exchanger without regular maintenance.

    At our service centres, Tranter can overhaul your frame and all your frame components if required. Liquid dye penetrant inspection is offered to ensure that the reconditioned plates are free from defects such as cracks and pinholes.

    Dirty plates effect heat transfer and reduce the overall performance.

  • GX-60GC-60

    GX-100 GX-140

    Connection size 200 mm

    Connection size 50 mm

    GX-51GC-51

    GX-64 GX-91

    Connection size 150 mm

    GL-13/GC-16

    GX-26GC-26

    GX-42

    Connection size 100 mm

    GX-85GL-85

    GX-145GL-145

    GX-205

    Connection size 300 mm

    GL-230, 330, 430

    Connection size 400/450/500 mm

    Marine Plate Heat Exchangers

  • Frame type N/P

    GL-13 50/65 320 832 140 592 135GC-16 50/65 320 832 140 592 135

    GX-26 N 100 450 1166 220 779 226GC-26 N 100 450 1166 220 779 226GX-42 N 100 450 1585 220 1189 226

    GX-51 N 150 585 1730 300 1143 300GC-51 N 150 585 1730 300 1143 300GX-64 P 150 626 1910 300 1320 285GX-91 P 150 626 2390 300 1800 285

    GX-60 P 200 825 1700 350 910 420GC-60 P 200 825 1700 350 910 420GX-100 P 200 825 2280 350 1490 420GX-140 P 200 825 2860 350 2070 420

    GL-85 P 300 1060 1985 360 1140 570GX-85 P 300 1060 1985 360 1140 570GL-145 P 300 1060 2565 360 1720 570GX-145 P 300 1060 2565 360 1720 570GX-205 P 300 1060 3215 360 2300 570

    GL-230 N 400 1510 3172 450 2090 700GL-230 N 450 1510 3172 450 2090 700GL-230 N 500 1510 3172 450 2090 700

    GL-330 N 400 1510 3782 417.5 2765 700GL-330 N 450 1510 3782 442.5 2715 700GL-330 N 500 1510 3782 450 2700 700

    GL-430 N 400 1510 4392 450 3310 700GL-430 N 450 1510 4392 450 3310 700GL-430 N 500 1510 4392 450 3310 700

    Type Connectionmm

    Bmm

    Hmm

    Dmm

    Emm

    Fmm

    Channel plate materials

    AISI 304

    AISI 316

    Titanium

    Max working pressure

    N 10 bar

    P 16 bar

    S 25 bar

    Gaskets

    Nitril

    EPDM

    FKM

    Viton

    Approvals

    SAQ, TTK, TV, ABS,

    GL, LRS, NK, BV,

    DNV, RINA, KR, ChinaClass,

    USSR

    Max working temperature

    Nitril 140C

    EPDM 160C

    FKM 180C

  • Conventional Plates (GC) The corrugated plates have a gasket along the periphery. There are also gaskets around two of the four ports, which means that only one of the two fluids has access to the heating surface. The next plate

    has gaskets around the other two ports. Thus a channel system is created where two fluids pass through every other channel respecti-vely. Leakage between the two fluids is not possible thanks to dou-ble gaskets around the ports. The pressure drop and heat transfer are dependent on factors such as the arrow angle of the plate pat-tern. An obtuse arrow angle (high-theta plate) means high resis-tance and a high thermal driving force. An acute angle (low-theta plate) means a low pressure drop but a lower thermal driving force.

    Ultraflex Plates (GX) Our unique, patented Ultraflex plate design features two angles for each plate size. The plates are available with a herringbone pattern with either an acute or obtuse angle, making it possible to achieve six combinations of channels. An obtuse angle (high-theta plate) gives high resistance an acute angle (low-theta plate) and a low pressure drop. This allows our heat exchangers to be optimized for the characteristics of each individual application. If

    you have different flow rates in the primary and secondary circu-its, your plate heat exchangers can be designed with asymmetri-cal channels for maximum heat transfer efficiency and economy.

    Our unique Ultraflex design allows the two plates to be turned and rotated, giving six combinations of high- and low-theta plate pairs, matching the performance parameters of your application.

    Low-theta plateHigh-theta plate

    Low-theta plateHigh-theta plate

    MS= Medium-theta, same direction

    LS= Low-theta,

    same direction

    MD= Medium-theta,

    different directions

    LD= Low-theta,

    different directionsUltraflex allows asymmetrical designs, with each circuit individually optimized for heat transfer.

    HD= High-theta,

    different directions

    HS= High-theta,

    same direction

  • Plate heat exchanger accessories

    Instrument flanges

    Liners

    Strainers

    Hydraulic tightening toolCIP Cleaning-in-PlaceBack flush

  • 9510

    0-95

    20

    EN

    G

    2010

    -09

    Tranter top quality, high-performance, proprietary products are on the job in demanding industrial and commercial installations around the world. Backed by our comprehensive experience and worldwide presence, Tranter offers you exceptional system performance, applications assistance and local service. Tranter is close to its customers, with subsidiary companies, agents, distributors and representatives located worldwide.Contact us for a qualified discussion of your needs.

    At the forefront of heat exchangertechnology for more than 70 years

    EuropeTranter International ABVnersborg, SwedenTel: +46 521 799 800Fax: +46 521 673 93E-mail: [email protected]

    North AmericaTranter, Inc.Wichita Falls, TX USATel: +1 940 723 7125Fax: +1 940 723 5131E-mail: [email protected]

    South America Tranter Ind e Com de Equip. LtdaCotia, BrazilTel: +55 11 360 841 54E-mail: [email protected]

    Middle East/Africa/AsiaTranter India Pvt. Ltd.Pune, IndiaTel: +91 2137 392300Fax: +91 2137 392354 E-mail: [email protected]

    China/Southeast AsiaTranter ChinaBeijing, ChinaTel: +86 10 8049 1790Fax: +86 10 643 79 490E-mail: [email protected]

    www.tranter.com, [email protected]