Heavy Duty Heating,Ventilation and Air
Conditioning Systems
Ken Collins704-330-4183
![Page 2: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/2.jpg)
Objectives
• Understand the basic theory of heavy-duty truck air-conditioning systems.
• Outline the requirements of the Clean Air Act that apply to a heavy-duty truck air-conditioning system.
• List the five major components of a heavy-duty air-conditioning system and describe how each works in the operation of the system.
![Page 3: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/3.jpg)
(Objectives cont.)
• Explain how the thermostatic expansion valve or orifice tube controls the flow of refrigerant to the evaporator.
• Identify the refrigerants used in heavy-duty truck air-conditioning systems.
• Describe the function of the main components in a typical heavy-duty air- conditioning system.
![Page 4: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/4.jpg)
(Objectives cont.)
• Recognize the environmental and personal safety precautions that must be observed when working on air-conditioning systems.
• Identify air-conditioning testing and service equipment.
• Test an air-conditioning system for refrigerant leaks.
![Page 5: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/5.jpg)
(Objectives cont.)
• Outline the procedure required to service a heavy-duty air-conditioning system.
• Perform some simple diagnosis of air-conditioning system malfunctions.
• Outline the advantages of connecting air-conditioning management electronics to the chassis data bus and explain how to access the system.
![Page 6: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/6.jpg)
(Objectives cont.)
• Explain how a truck cab ventilation system operates.
• Describe the role a liquid-cooled heating system plays in a truck cab heating system.
• Describe some types of auxiliary heating and power units.
![Page 7: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/7.jpg)
INTRODUCTION
Heating, ventilation, and air-conditioning (HVAC) systems are designed to keep the cab, or cab and bunk, in a truck at a comfortable temperature. The air conditioning system also helps clean (condition) the air in the cab by removing dust, pollen, smoke, and moisture.
![Page 8: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/8.jpg)
THERMODYNAMICS
To understand air-conditioning theory, it is important for the service technician to have a basic understanding of how heat behaves. The behavior of heat is a branch of physics known as thermodynamics. An air-conditioning system uses some very basic thermodynamic principles to remove heat from the cab of a truck and dissipate or lose it to the atmosphere outside the truck.
![Page 9: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/9.jpg)
How air is “conditioned” in the cab.
![Page 10: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/10.jpg)
PRINCIPLES OFREFRIGERATION
Air-conditioning and refrigeration systems manage basic thermodynamic principles to produce a more comfortable climate within an enclosed area. To understand how an air-conditioning system works, we first have to know something about the states of matter, heat flow, and something called latent heat.
![Page 11: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/11.jpg)
STATES OF MATTER
• Solid water is known as ice.• Liquid water is known as water.• Vaporized water is known as steam.
The temperature of the water determines which of these three states it is in.
![Page 12: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/12.jpg)
Absolute Heat, Heat Movement,and Measurement
![Page 13: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/13.jpg)
Pressure and Heat
The temperature at which a liquid boils depends on the pressure acting on the liquid. Decreasing the pressure lowers the boil point. Increasing the pressure raises the boil point.
![Page 14: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/14.jpg)
Latent Heat
Whenever a substance changes state, it either releases or consumes heat energy. Latent heat is the amount of heat necessary to change a substance from one state to another.
![Page 15: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/15.jpg)
SUMMARY OF AIR CONDITIONINGPRINCIPLES
• Heat always moves from a warmer area to a cooler area.
• When liquids are heated and evaporate to a vapor state, heat is absorbed.
• When a gas condenses from a vapor to a liquid state, heat is released.
![Page 16: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/16.jpg)
Typical heavy-duty truck heating and an air-conditioning system
![Page 17: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/17.jpg)
REFRIGERANT
The function of a refrigerant is to absorb heat from the air in the cab and transfer it to the atmosphere outside the cab. The refrigerants used in truck A/C systems are industrially manufactured chemicals of some complexity. Refrigerants in mobile systems are controversial and constantly undergoing change.
![Page 18: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/18.jpg)
CHLOROFLUOROCARBONREFRIGERANTS
Until 1995, the common refrigerant used in a truck A/C system was known as R-12. This is classified as a chlorofluorocarbon (CFC). R-12 refrigerant boils at −22°F (−30°C, and for years, it was considered an ideal mobile vehicle A/C refrigerant. However, because it is a substance of some toxicity as well as ozone depleting, its use has in theory become strictly controlled under the guidelines of the federal Clean Air Act.
![Page 19: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/19.jpg)
HYDROCHLOROFLUOROCARBONS(HCFCS)
• HCFC 134a – used in automobile and truck cab HVAC systems
• HCFC 22 – used in trailer reefer systems• HCFC 40a – used in trailer reefer systems
![Page 20: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/20.jpg)
Ozone Depletion
Depletion of the ozone layer has occurred at a rate of around 4 percent per decade since the mid-1970s and is beyond the scope of this textbook. A simple explanation requires understanding a little about ozone. Ozone in the upper atmosphere filters out some of the harmful sunlight directed toward Earth. Chemically, ozone (O3) is triatomic oxygen; that is, three oxygen atoms bond to form an O3 molecule.
![Page 21: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/21.jpg)
Future Refrigerants
Europe currently requires trailer reefers to be equipped with electrical standby for use whenever a vehicle is parked so that CO2 is not produced while running an onboard reefer engine. To minimize refrigerant losses, flared fittings are being phased out in favor of brazed unions, reducing the incidence of leaks. Also under consideration are the use of hybrids and semi-hermetic compressors.
![Page 22: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/22.jpg)
Refrigerant Oils
HCFCs require the use of two refrigerant specific oils:
• Polyalkylene glycol (known as PAG)
• Polyolester (known as POE or ester)
![Page 23: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/23.jpg)
REFRIGERANT CONTAMINATION
R-134a systems look similar to R-12 systems. However, refrigerants should never be mixed in a system; to emphasize this fact, it has been made illegal. Guidelines issued by the Environmental Protection Agency (EPA) specify that all refrigerants must be approved under the Significant New Alternatives Policy (SNAP). Only R-134a meets current SNAP guidelines for mobile refrigerants, but a number of other mobile refrigerants are under research.
![Page 24: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/24.jpg)
Temperature/pressure relationship of refrigerant
![Page 25: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/25.jpg)
Shop Talk
Refrigerant containers for R-12 and R-134a are color-coded. R-12 containers are white and R-134a containers are light blue and clearly marked. In addition, R-134a containers use ½-inch 16 acme threads, which cannot be connected to an R-12 gauge set or recovery machine.
![Page 26: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/26.jpg)
Refrigerant identifier
![Page 27: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/27.jpg)
REFRIGERANT RECOVERY
The Clean Air Act, passed in 1992, has resulted in major changes in industrial, domestic, and vehicle A/C systems.
![Page 28: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/28.jpg)
AIR-CONDITIONING CERTIFICATION
Three training programs in particular are recognized by the federal government: the Mobile Air Conditioning Society (MACS), the International Mobile Air Conditioning Association (IMACA), and the National Institute of Automotive Service Excellence (ASE).
![Page 29: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/29.jpg)
THE REFRIGERATION CYCLE
![Page 30: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/30.jpg)
AIR-CONDITIONING SYSTEMCOMPONENTS
![Page 31: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/31.jpg)
Refrigerant Flow Cycle
![Page 32: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/32.jpg)
Piston-Type Compressors
![Page 33: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/33.jpg)
Cutaway view of a piston-type compressor
![Page 34: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/34.jpg)
Rotary Vane Compressor
![Page 35: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/35.jpg)
Cutaway view of a typical rotary vane compressor
![Page 36: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/36.jpg)
Swashplate-Type Compressors
![Page 37: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/37.jpg)
Compressor Drives
![Page 38: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/38.jpg)
CONDENSER
![Page 39: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/39.jpg)
RECEIVER/DRYER
![Page 40: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/40.jpg)
Binary Switch
![Page 41: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/41.jpg)
Trinary Switch
The trinary switch is mounted on the receiver/dryer in a similar fashion to the binary switch. The trinary pressure switch performs three functions to monitor and control pressure inside the A/C system. The low- and high-range functions are the same as on the binary switch system.
![Page 42: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/42.jpg)
Pressure Relief Valve
A pressure relief valve is also often located on the receiver/dryer. It provides an added high-pressure relief feature if a failure were to develop in the high pressure cut-off switch. The pressure relief valve is designed to pop off when the refrigerant pressure exceeds a preset maximum safe pressure value. Pop off pressure can often be as high as 400 psi.
![Page 43: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/43.jpg)
Fusible Plug
![Page 44: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/44.jpg)
Accumulator
![Page 45: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/45.jpg)
THERMOSTATIC EXPANSION VALVE/ ORIFICE TUBE
![Page 46: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/46.jpg)
Thermostatic Expansion Valve (TXV)
![Page 47: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/47.jpg)
Orifice Expansion Tube
![Page 48: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/48.jpg)
EVAPORATOR
![Page 49: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/49.jpg)
THERMOSTAT (EVAPORATOR FREEZE PROTECTION DEVICE)
![Page 50: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/50.jpg)
REFRIGERATION LINES, HOSES,AND COUPLERS
![Page 51: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/51.jpg)
Hose clamp shell crimp fittings will not seal the new style barrier hose.
![Page 52: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/52.jpg)
New hoses are designed to prevent refrigerant leakage.
![Page 53: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/53.jpg)
Special Crimping Tools
![Page 54: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/54.jpg)
SIGHT GLASS
![Page 55: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/55.jpg)
IN-LINE DRYER
Located between the receiver/dryer and TXV or tube, an in-line dryer absorbs any moisture that gets by the receiver/dryer. It also helps to prevent TXV or tube freeze-up.
![Page 56: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/56.jpg)
MUFFLER
The muffler is usually located on the discharge side of the compressor. It also may be located on the suction side. Its function is to reduce the characteristic pumping noise produced by the compressor.
![Page 57: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/57.jpg)
BLOWER MOTOR AND FAN
![Page 58: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/58.jpg)
ENGINE COOLING FAN
![Page 59: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/59.jpg)
Shop Talk
Remember that just one drop of water added to refrigerant will lead to corrosion and refrigerant breakdown. Corrosive hydrochloric acid can be produced in the older R-12 system when trace drops of water are added. Also, the smallest amounts of air in the refrigerant system can start chemical reactions that result in system malfunctions.
![Page 60: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/60.jpg)
SAFETY PRECAUTIONS
Refrigerant lines are under some pressure even when the system is not running. This means that they should not be disconnected until the refrigerant has been discharged to a refrigerant recovery unit. Refrigerants are safe when handled properly.
![Page 61: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/61.jpg)
CAUTION!
Refrigerant should never come into contact with skin or eyes. Liquid refrigerant, when exposed to the air, quickly evaporates and will almost instantly freeze skin or eye tissue. Serious injury or blindness could result.
![Page 62: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/62.jpg)
CAUTION!
Avoid working in areas where refrigerant may come into contact with an open flame or any burning material, such as a cigarette. When it contacts extreme heat, refrigerant breaks down into poisonous phosgene gas, which, if breathed, causes severe respiratory irritation.
![Page 63: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/63.jpg)
CAUTION!
Under current federal Clean Air Act regulations, refrigerants must be recovered and recycled by all users to protect the environment and should never be released into the atmosphere. Under these regulations, service facilities not having the required recovery and recycling equipment and properly trained and certified personnel are not permitted to perform any refrigeration service work.
![Page 64: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/64.jpg)
Refrigerant Storage
Because of its very low boiling point, refrigerant has to be stored under pressure in containers. These containers should never be exposed to temperatures higher than 125°F. Refrigerant cans should not be left in direct sunlight.
![Page 65: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/65.jpg)
PERFORMANCE TESTING ANAIR CONDITIONING SYSTEM
Because there are differences in each OEM system, this is just a general set of guidelines, and the best approach to testing and troubleshooting a system is to use the OEM service manual.
![Page 66: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/66.jpg)
Cooling Check
![Page 67: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/67.jpg)
Odor Diagnosis
A/C systems may produce a musty odor, usually at startup in hot weather. This type of odor is usually temporary, and, providing it disappears after a short period of operation, should not be of concern. If it persists, it can be an indication of microbial growth on the evaporator core. This requires the removal of the evaporator core and its thorough cleaning with a disinfectant. Some other odor diagnoses are shown in Table 35–1 page 23.
![Page 68: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/68.jpg)
LEAK TESTING A SYSTEM
![Page 69: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/69.jpg)
![Page 70: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/70.jpg)
CAUTION!
Never pressure or leak test R-134a service equipment or vehicle A/C systems with compressed air. Some mixtures of air and R-134a have been shown to be combustible at elevated pressures.
![Page 71: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/71.jpg)
Shop Talk
Because of their sensitivity, electronic-type detectors must be correctly calibrated before each use to detect the lowest permissible leak rate of the component being checked. Trace the refrigerant system in a continuous path so that no potential leaks are missed. If a leak is found, always continue to test the remainder of the system.
![Page 72: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/72.jpg)
Shop Talk (Cont.)
At each area checked, the probe should be moved around the location at a rate no more than 1 to 2 inches/second and no more than 1/4 inch from the surface completely around the position. Slower and closer movement of the probe greatly improves the likelihood of finding a leak. It also helps to place the probe lower than a suspected leak because the refrigerant is heavier than air.
![Page 73: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/73.jpg)
MANIFOLD GAUGE SETS
R-12 R-134a
![Page 74: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/74.jpg)
![Page 75: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/75.jpg)
CAUTION!
Never open the high-side hand valve with the system operating and a refrigerant source at the center hose connection. This will cause refrigerant to exit the A/C system under high pressure into the source container, which could cause it to burst. The only time both hand valves should be open is when evacuating the system.
![Page 76: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/76.jpg)
Shop Talk
Atmospheric pressure reduces as altitude increases. The gauge pressure must be corrected using an OEM correction chart when checking system lowside pressures.
![Page 77: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/77.jpg)
Service Valves
![Page 78: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/78.jpg)
Schrader Type
![Page 79: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/79.jpg)
Shop Talk
In R-12 systems, the Schrader fitting on the high pressure side is smaller than the low-pressure side, and special adapters are necessary to connect the high-side service hose into the system. The difference in fitting sizes is to prevent mixing up the high and low-pressure sides of the system when attaching he gauge set.
![Page 80: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/80.jpg)
Shop Talk
The different size fittings were introduced to prevent disposable 1 lb cans of refrigerant from being connected to the high side of the system, causing them to explode. After disconnecting the gauge lines, check the valve areas to be sure that the service valves are correctly seated and that the Schrader valves are not leaking. In R-134a systems, the size as well as the type of connection is different; that is, the larger connection is used for the high side.
![Page 81: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/81.jpg)
MANIFOLD SERVICE HOST SETS
![Page 82: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/82.jpg)
Vacuum Pump
![Page 83: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/83.jpg)
Rotary Vane-Type Vacuum Pump
![Page 84: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/84.jpg)
Shop Talk
A vacuum pump is unable to remove moisture in liquid state from a system. It lowers the system pressure and, therefore, the boiling point of liquid moisture. It then removes the vaporized moisture. This is why it is necessary to pull a vacuum on a system for an extended period to ensure that no moisture is left in it.
![Page 85: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/85.jpg)
Thermistor Vacuum Gauge
The electronic thermistor vacuum gauge is designed to work with the vacuum pump to measure the last, most critical inch of Hg vacuum during evacuation. It constantly monitors and visually indicates the vacuum level so that a technician will know for sure when a system is entirely free of air and moisture.
![Page 86: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/86.jpg)
AIR CONDITIONING SERVICEPROCEDURES
• System recovering and recycling• System flushing• Compressor oil level checks• Evacuation• System recharging
![Page 87: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/87.jpg)
CHARGING CYLINDER ORCHARGING STATION
![Page 88: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/88.jpg)
Typical Refrigerant Stations
![Page 89: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/89.jpg)
![Page 90: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/90.jpg)
Discharge and Suction Service Valves.
![Page 91: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/91.jpg)
Recovery Hookup
![Page 92: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/92.jpg)
PURGING
![Page 93: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/93.jpg)
![Page 94: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/94.jpg)
CHECKING COMPRESSOR OIL LEVEL
![Page 95: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/95.jpg)
EVACUATING THE SYSTEM
![Page 96: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/96.jpg)
TOP-OFF RECHARGE OFAN A/C SYSTEM
![Page 97: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/97.jpg)
Weighing a Refrigerant Canister
![Page 98: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/98.jpg)
COMMON AIRCONDITIONING PROBLEMS
![Page 99: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/99.jpg)
Performance Testing
![Page 100: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/100.jpg)
Troubleshooting Flow Chart
![Page 101: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/101.jpg)
CONVERTING AN R-12 SYSTEM TO AN R-134A SYSTEM
In theory, R-12 should not be available today, meaning that every retrofit should have taken place. In reality R-12 is still readily available. This means that there are trucks running R-12 systems. It also means that shops continue to the process of retrofitting systems to comply with the MACS standards. Some of the systems are being aftermarket retrofit to blend systems.
![Page 102: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/102.jpg)
AIRFLOW
![Page 103: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/103.jpg)
LIQUID-COOLED HEATINGSYSTEM
![Page 104: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/104.jpg)
HEATER CORE
A typical heater core is designed and constructed very much like a miniature engine cooling radiator. It features inlet and outlet tanks connected by headers to a heat exchanger core. The heater core tank, tubes, and fins can become clogged over time by rust, scale, and mineral deposits circulated by the coolant.
![Page 105: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/105.jpg)
HEATER CONTROL VALVE
A heater control valve, also known as a coolant flow valve, controls the flow of coolant into the heater core from the engine. In a closed position, the valve allows no flow of hot coolant to the heater core, allowing it to remain cool.
![Page 106: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/106.jpg)
THERMOSTAT
The thermostat that helps to regulate the engine coolant temperature plays a role in providing the cab with heat. A malfunctioning thermostat can cause the engine to overheat or not reach normal operating temperature, and either of these conditions will impact the cab heater performance.
![Page 107: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/107.jpg)
COMBINATION HVAC CORE
![Page 108: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/108.jpg)
Cable-Controlled Coolant Valve
![Page 109: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/109.jpg)
Control Panel and Airflow
![Page 110: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/110.jpg)
Sleeper Compartment Heaterand Air Conditioner
![Page 111: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/111.jpg)
Supplementary Coolant Heater
![Page 112: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/112.jpg)
Auxiliary Power Units (APUs)
![Page 113: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/113.jpg)
ELECTRONICALLY MANAGEDCLIMATE CONTROL
Most heavy-duty trucks use some level of electronic controls to manage cab climate. The terms used to describe these control systems are air-conditioning protection and diagnostics system (APADS) and air-conditioning protection unit (ACPU).
![Page 114: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/114.jpg)
COMPUTER-CONTROLLEDA/C COMPONENTS
System components include the A/C control module, which performs logic processing of the system inputs and switches the outputs. It also includes an input and output circuit. The A/C control module masters A/C operation and tracks diagnostic data. It is usually located somewhere in the engine compartment rather than in the vehicle cab.
![Page 115: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/115.jpg)
A/C Clutch Coil
![Page 116: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/116.jpg)
A/C Control Logic
![Page 117: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/117.jpg)
BLUECOOL HEATEXCHANGER
![Page 118: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/118.jpg)
BLUECOOL OPERATION
BlueCool uses a pair of aluminum coil circuits surrounded by a graphite matrix storage core contained in insulation. One coil circuit carries R-134a refrigerant gas and the other a 50/50 mixture of ethylene glycol (EG) and water. The system uses an icebox principle. The graphite matrix absorbs water in liquid both liquid and frozen states. The storage coil is chilled down to subzero temperatures while the truck is operated on the road.
![Page 119: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/119.jpg)
Summary
• Heavy-duty heating and air-conditioning (A/C) systems are designed primarily to keep the cab comfortable despite the outside weather.
• Liquids absorb heat when changed from a liquid state to a gas.
• Gases release heat when changed from a gaseous state to a liquid.
![Page 120: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/120.jpg)
Summary (cont.)
• Heat always moves from a hotter area to a cooler area.
• The temperature at which a liquid changes state to a gas depends on the pressure acting on it.
• Refrigerants are required to have a low boil point and to change quickly from a liquid state to a gas state and back again.
![Page 121: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/121.jpg)
Summary (cont.)
• The basic refrigeration cycle consists of compression, condensation, expansion, and evaporation.
• Compression heats up refrigerant gas. Condensation changes the state of the refrigerant from a gas to a liquid. Expansion reduces the pressure of the liquid refrigerant. Evaporation changes the refrigerant from a liquid state to a gas.
![Page 122: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/122.jpg)
Summary (cont.)
• There are two types of refrigerant lines: suction lines and discharge lines.
• A/C systems are sensitive to moisture and dirt. Clean working conditions are extremely important.
• The electrical system must be checked periodically to prevent the truck A/C system from failing unexpectedly.
![Page 123: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/123.jpg)
Summary (cont.)
• Some trucks use electronic climate and A/C controls. These systems can either be stand-alone or connected to the chassis data bus.
• Current A/C system controllers are networked to the chassis data bus. This enables them to communicate with other MIDs to optimize system operation.
![Page 124: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/124.jpg)
Summary (cont.)
• When the A/C controller is networked to the chassis data bus, the system is accessed by the J1939 connector. This allows the system to be read by any software that can interpret MIDs, parameter identifiers (PIDs), subsystem identifiers (SIDs) and FMIs. To perform operations other than simply read the system, proprietary software is usually required.
![Page 125: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/125.jpg)
Summary (cont.)
• The A/C electronics can respond to a request off the data bus to put the A/C compressor into dropout mode. An example would be a temporary request for full power from the engine electronics, when it would be desirable to eliminate as many parasitic loads as possible.
![Page 126: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/126.jpg)
Summary (cont.)
• BlueCool uses an icebox principle to cool truck bunks during engine shutdown at zero fuel consumption and with no emissions.
![Page 127: Heavy Duty Heating, Ventilation and Air Conditioning Systems](https://reader035.vdocuments.net/reader035/viewer/2022081506/56813cc2550346895da66ea7/html5/thumbnails/127.jpg)
Any Questions ?