The RheoCap SoftwareThe unique project and job stream structure enables the userto customize the software from straight forward QualityControl tests - push a button and pick up the test report - tocustom tailored measurements. Different user levels guaran-tee a minimum of user errors and a maximum of repeatabilityplus data safety. Bagley and Weißenberg-Rabinowitsch datacorrection, data analysis and evaluation with rheological andmathematical models and the determination of elongation vis-cosity according to Cogswell are part of the package. For fur-ther evaluations a convenient data export to other softwareapplications is available. The recommended operating systemfor the RheoCap Software is Microsoft Windows XP.

Exchangeable Pistons and Barrels

The Rheoflixer is a high pressure capillary rheometer for the determination of the flow

behavior of polymers as a function of shear rate and temperature. The computer con-

trolled instrument covers a wide range of shear rates with a variety of measurement

dies. Rod dies, Slit dies and a special sensor for PVC gelation tests complete

the measuring capabilities of the RheoFlixer.

RheoflixerHigh-Pressure Capillary Rheometer

Specifications Rheoflixer

Maximum speed 18 mm/secMinimum speed 0.0018 mm/secMaximum force 20 kNMaximum pressure 2000 barTemperature range 60 – 400°CTemperature stability +/- 0.5 KTemperature PID control loops 2Thermo couples 2 type KPower supply 3x400/230V, 50/60Hz, N, PEStandards ISO 11443, ASTM D 3835, DIN 54811

Priciple of the High-Pressure Capillary Rheometer

Dies and cylindersVarious dies are available to cover a wide shear rate range. The Rheoflixer can beused with a variety of rod and slit capillary dies and an elongation die. Rod capillarydies made out of wear resistant tungsten carbide are available with 0.5, 1 and 2 mmdiameter and 0.5 to 40 mm in length. The range of slit capillary dies range from0.5 to 2 mm in slit sizes.For different sample volumes three cylinders and pistons are available having 9.5,12 or 15 mm diameter. The easy exchange of cylinders and pistons allow a highuser flexibility.

Measurement cylinder

Pressure transducer

Capillary

Heater

Test Sample

Load CellSpeed = const.

Measurement Piston Rod Capillary Dies

Slit Capillary Die

RheoStress, RotoVisco, RheoWin, RheoWizard and RheoWave are registered trademarks of Thermo Haake GmbH . The product information in this document was correct at the timeof printing, however specifications are subject to alteration without notice due to the Thermo Haake philosophy of continual product innovation and development and any informa-tion contained herein should not be construed as a contractual commitment by Thermo Haake. All orders are accepted subject to our current Conditions of Sale, copies of which areavailable on request. © Thermo Haake / Dec 2001 623-3050

A Thermo Electron business

InternationalThermo HaakeDieselstr. 476227 KarlsruheGermanyTel. +49(0)721 40 94-0Fax +49(0)721 40 94 300Hotline +49(0)18 05 [email protected]

USAThermo Haake5225 Verona RoadMadison, WI 53711Tel. 608-327-6777Fax [email protected]

FranceThermo Rheo99 route de Versailles91160 ChamplanTel. +33(0) 01 64 54 01 01Fax +33(0) 01 64 54 01 [email protected]

UKThermo PRISMEmerald WayStone Business Park, StoneStaffordshire ST15 OSRTel. +44 (0) 1785 813 648Fax +44 (0) 1785 814 [email protected]