hihomes concrewall design build market
TRANSCRIPT
HIHOMES CONCREWALL BUILDING TECHNOLOGY
www.Hihomes.Pk Innovation in Built
Environment www.hihomes.pk
TEAM1. Dott. Ing. Duilio Locatelli
2. Engr Farooq e Azam
3. Hujaj KhanWhere the universe
blendsHihomes
D&B Innovation Built Environment
Chapter 9, Surah Taubah, aayats 108-109:
the mosque which has been founded on piety from the very first day is the proper place for you to stand for prayer
“
Site Panels Assembling -Scafolding
Roof Panels Reinforcing
Roof Concrete Pouring
1. SIMPLICITY IN THE SITE ASSEMBLING, WITH GEOMETRIES PREDISPOSED IN FACTORY
2. SITE LIFTING AND THE LIGHTNESS
3. DEAD LOAD REDUCED WITH NOTABLE REDUCTION OF THE SEISMIC MASSES;
4. THERMAL ISOLATION CONTINUITY.
LIGHT MATERIAL
EASY TO INSTALL - FAST
CONSTRUCTION
FIRE RESISTANT
ENERGY EFFICIENT
LOWER UTILITY COSTS
EARTHQUAKE RESISTANT
VERSATILE –FLEXIBLE DESIGN
STORMS RESISTANT
SUPERIOR STRENGTH
Geograhic Presence
SEVERAL INSTALLATION OF PLANT CONCREWALLPRODUCTION IN THE WORLD:ALGERIA, ANGOLA, BULGARIA, DOMINICAN REPUBLIC, GHANA, GUINEA ECUATORIAL, INDIA, INDONESIA, IRAN, ITALIA, JAMAICA, KENYA, MALAYSIA, MEXICO, MONGOLIA, PANAMA, RDC, ROMANIA, SAUDI ARABIA, SPAIN, SOUTH AFRICA, TUNISIA, UNITED ARAB EMIRATES, VENEZUELA.
THERMAL TRANSMITTANCE
Single Panel PCS08
Up = 0,58 W/m2K
HIGH THERMAL INSULATIONTHE POSITION OF CONNECTORS IS PUNCTUAL AND IT DOESN'T REPRESENT A PROBLEM = THERMAL CONDUCTIVITY. THE JOINT METALLIC CONNECTORS ARE 40 PER M2 WITH 3 MM DIAMETER, AND SURFACE Ø3 = 0.07 CM2, IN PERCENTAGE THEY REPRESENT LESS THAN 0.03% OF THE SURFACE OF THE PANEL.
MECHANICAL RESISTANCE TESTS: COMPRESSION
NUMEROUS TESTS OF CENTERED AND ECCENTRIC COMPRESSION HAVE BEEN PERFORMED ON SINGLE PANELS WITH DIFFERENT THICKNESS IN THE
LABORATORY OF THE MARCHE POLYTECHNIC UNIVERSITY. THE MAXIMUM COMPRESSION LOAD WAS 70 T, 23 T WITH A SAFETY FACTOR 3.
STATIC LOAD TEST ON A SINGLE FLOOR PANEL 12 cm
LOAD TEST
DISTRIBUTED LOAD ACTING ON THE
PORTION OF THE FLOOR OF 2000
KGF / SQ.
FILLING A WATER TANK WITH
DIMENSIONS IN PLAN OF 300 CM X
300 CM AND HEIGHT 200 CM.
MISSILE TEST Wind Science & Engineering Research Center_Texas Tech University
•130 mm and 150 mm panels - are resistant to the Florida Building Code & Dade County
Hurricane Envelope resistance = 55 km/h missile & 225 km/h hurricane (34 mph & 140
mph hurricane).
•130 mm panel - threshold of perforation = 129 km/h missile & 322 km/h hurricane (80
mph & 200 mph hurricane) impact resistance, however since panel cracking becomes an
issue with each impact, the panel resistance therefore considered as 122 km/h missile &
306 km/h hurricane (76 mph impact/190 mph). These are ICC-500 Storm Shelter
standards.
The realization of the external infilling walls for residential buildings with thermal insulating panels "Concrewall" introduces the interesting described advantages and is a technique of application of easy realization on site.
ALTERNATIVE WAY TO COMPLETE THE PANELS -PANEL CAST IN FORMWORK
1. CONTINUOUS INSULATION;
2. RESOLVED THE ISSUES RELATED TO THE APPLICATION OF THE PLASTER SPRAYED;
3. DEAD LOAD REDUCED WITH NOTABLE REDUCTION OF THE SEISMIC MASSES;
4. LOWER AMOUNT OF CEMENT, COST REDUCTION.
8. WINDOWS FRAME 10. PLASTER FINISHING
9. WINDOWS THRESHOLD 11. PLASTER FINISHING
12. MEMBRANE
13. TILEING
2,59,271,000,000Countries With Highest GDP From Construction - Top 5 World
Uruguay - Turkey – Paraguay – Chile -Mexico
GDP From Construction in Pakistan increased to 259271 PKR Million in 2014 from 242203 PKR Million in 2013.
GDP From Construction in Pakistan averaged 226289.20 PKR Million from 2005 until 2014, reaching an all time high of 259271 PKR Million in 2014
Thanks!
Any questions?
Hujaj Khan
+923458551887
www.hihomes.pk
https://www.facebook.com/hihomes.pk
www.linkedin.com/in/hihomes
Head office
Safdar Mansion, 16-D 3rd Floor Fazl-e-
Haq Road Blue Area Islamabad 44000
London Office
The Lodge, Sheepcote Road, Harrow
HA1 2HD UK