hole cutting instructions - oldcastle infrastructure...astm c 579 astm d 790 astm c 99 astm c 97...

2
oldcastleprecast.com/enclosuresolutions 559-675-1813 Items Needed • 1/4” carbide tipped masonry drill bit • Corded drill with handle • Diamond tipped masonry hole saw • Tape measure • Pen/Pencil • Cordless drill (optional) (optional) Instructions • Using the tape measure find where you want your hole to be and mark it with a Pen/Pencil. • Once your hole is marked take your drill with a 1/4” carbide tipped masonry bit and drill at the center of where you want your hole. • Using the corded drill with a handle and a diamond tipped masonry hole saw attached make your cut with the guide in the pilot hole. • Use the diagram on the following page for acceptable hole cutting areas. Always follow your company safety procedures when performing this operation. Hole cut in long wall Hole cut over rib on short wall 3 5 4 6 HOLE CUTTING INSTRUCTIONS IM05v02 ©2016 Oldcastle, Inc. 1 2

Upload: others

Post on 02-Aug-2021

48 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HOLE CUTTING INSTRUCTIONS - Oldcastle Infrastructure...ASTM C 579 ASTM D 790 ASTM C 99 ASTM C 97 ASTM D 2444 ASTM C 1028 ASTM D 543 > 12,500 PSI > 3,000 PSI ≤ 0.25% > 70 FT-LB >

oldcastleprecast.com/enclosuresolutions 559-675-1813

Items Needed

• 1/4”carbidetippedmasonrydrillbit

• Cordeddrillwithhandle• Diamondtippedmasonryholesaw

• Tapemeasure• Pen/Pencil• Cordlessdrill(optional)

(optional)

Instructions

• UsingthetapemeasurefindwhereyouwantyourholetobeandmarkitwithaPen/Pencil.

• Onceyourholeismarkedtakeyourdrillwitha1/4”carbidetippedmasonrybitanddrillatthecenterofwhereyouwantyourhole.

• Usingthecordeddrillwithahandleandadiamondtippedmasonryholesawattachedmakeyourcutwiththeguideinthepilothole.

• Usethediagramonthefollowingpageforacceptableholecuttingareas.

Alwaysfollowyourcompanysafetyprocedureswhenperformingthisoperation.

Hole cut in long wall

Hole cut over rib on short wall

3

5

4

6

HOLE CUTTING INSTRUCTIONS

IM05v02©2016 Oldcastle, Inc.

1 2

Page 2: HOLE CUTTING INSTRUCTIONS - Oldcastle Infrastructure...ASTM C 579 ASTM D 790 ASTM C 99 ASTM C 97 ASTM D 2444 ASTM C 1028 ASTM D 543 > 12,500 PSI > 3,000 PSI ≤ 0.25% > 70 FT-LB >

oldcastleprecast.com/enclosuresolutions 559-675-1813IM05v02©2016 Oldcastle, Inc.

THE FOLLOWING MATERIAL PROPERTIES FOR POLYMER CONCRETE PRODUCTS WERE ESTABLISHED THROUGH INDEPENDENT THIRD PARTY TESTING:

COMPRESSIVE STRENGTHFLEXURAL STRENGTHMODULAS OF RUPTUREWATER ABSORPTIONIMPACT RESISTANCEFRICTION COEFFICIENTCHEMICAL RESISTANCE

ASTM C 579ASTM D 790ASTM C 99ASTM C 97ASTM D 2444ASTM C 1028ASTM D 543

> 12,500 PSI> 3,000 PSI≥ 3,000 PSI≤ 0.25%> 70 FT-LB> 0.5RESISTANT, > 75% RETENTIONPHYSICAL PROPERTIES

CONDUIT DRILLING GUIDELINES

NOTE: MINIMUM HOLE SEPARATION SHALL BE AT LEAST ONE_HALF (1/2) OF THE MINIMUM HOLE SIZE DIAMETER.

NOTES: CONDUIT PROVISIONS MAY BE DRILLED ANYWHERE WITHIN THE ACCEPTABLE PENETRATION AREA.QUANTITY OF ALLOWABLE PENETRATIONS VARIES BASED ON MIN HOLE SIZE AND MINIMUM HOLE SEPARATION.

MATERIAL PROPERTIES

ACCEPTABLE PENETRATION AREAS

LONG WALL(DEPTH VARIES - PC1730 SHOWN)

FLAT FLAT FLAT

SHORT WALL(DEPTH VARIES - 1730 SHOWN)

HOLE CUTTING INSTRUCTIONS