HTTF RELAP5-3D Applications and AssessmentPaul D. Bayless
International RELAP5 Users Group MeetingSeptember 11-12, 2014
![Page 2: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/2.jpg)
Overview• High Temperature Test Facility (HTTF) description• Recent RELAP5-3D analyses• Future plans
2
![Page 3: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/3.jpg)
High Temperature Test Facility highlights• Integral experiment being built at Oregon State University• 2.2 MW electrically-heated, scaled model of a high temperature gas
reactor– Reference is the Modular High-Temperature Gas-cooled Reactor
(MHTGR) (prismatic blocks)– Large ceramic block representing core and reflectors – ¼ length scale– Prototypic coolant inlet (259°C) and outlet (687°C) temperatures– Less than scaled power– Maximum pressure of ~700 kPa
• Primary focus is on depressurized conduction cooldown transient
3
![Page 4: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/4.jpg)
HTTF RELAP5-3D Input Model Description
• Four systems– Primary coolant– Secondary coolant– Reactor cavity– Reactor cavity cooling system (RCCS)
• Central and side reflector regions divided into regions with or without coolant holes
• 2-D (radial/axial) conduction in all vertical heat structures• Heater block unit cell centered on the coolant channel• Radial conduction and radiation inside core barrel• Radiation from core barrel to vessel to RCCS
4
![Page 5: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/5.jpg)
Reactor Vessel Nodalization• Multiple flow paths through core
– Three heated channels– Central reflector– Side reflector
• Gaps on either side of permanent side reflector not flow-through
• Riser annulus between core barrel and pressure vessel
• No coolant between upper plenum shield and upper head
5
![Page 6: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/6.jpg)
HTTF RELAP5-3D Core Region Radial NodalizationReactor vessel
Core barrel
Coolant
Central reflector
Core region
Permanent reflector
Coolant gapsHeater rodCoolant hole
Side reflector
6
![Page 7: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/7.jpg)
HTTF Ex-vessel Nodalization
7
![Page 8: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/8.jpg)
Steady state scoping calculations• Effect of reduced power• Effect of reduced pressure• Maintain nominal coolant inlet and outlet temperatures• Can a representative core temperature distribution be maintained?• Can operational costs be reduced?
8
![Page 9: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/9.jpg)
Effect of primary coolant system pressure
700 kW 2200 kW
9
![Page 10: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/10.jpg)
Effect of power on axial average temperatures
10
![Page 11: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/11.jpg)
Effect of power on core block 2 temperatures
11
![Page 12: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/12.jpg)
Effect of power on core block 6 temperatures
12
![Page 13: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/13.jpg)
Effect of power on core block 10 temperatures
13
![Page 14: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/14.jpg)
Depressurized conduction cooldown transient• 5-s forced flow coastdown• System depressurization valve opened at 3 s• At 20 s
– System depressurization valve closed– Hot and cold duct break valves opened– Loop isolation valve closed
• Scram assumed at transient initiation (0 s)
14
![Page 15: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/15.jpg)
Core ceramic temperature response
15
![Page 16: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/16.jpg)
Central reflector temperature response
16
![Page 17: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/17.jpg)
Side reflector temperature response
17
![Page 18: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/18.jpg)
Outer structure temperature response
18
![Page 19: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/19.jpg)
How low can the power go?
19
![Page 20: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/20.jpg)
Summary of results• System pressure had little effect on core temperature distribution• In general, decreasing power at steady state
– Increased the central reflector temperatures– Reduced the core temperatures– Reduced the side reflector temperatures
• Lower power resulted in lower temperatures during the depressurized conduction cooldown transient
– Effect not as large as in initial temperature difference– Decay power is the same in all cases
• Reduced power operation may be viable for many cases– Lower electricity cost– Less water usage
• Model must still be benchmarked!
20
![Page 21: HTTF RELAP5-3D Applications and Assessment Documents... · Overview • High Temperature Test Facility (HTTF) description • Recent RELAP5-3D analyses • Future plans 2](https://reader031.vdocuments.net/reader031/viewer/2022030808/5b1698707f8b9a4f6d8cd19e/html5/thumbnails/21.jpg)
Future plans• Update model when final drawings and component information is
available• Benchmark model using system characterization test data• Perform assessment calculations using transient test data• Provide operational support analyses as needed