hydraw cad 2019 - vestusa.coms-new.pdf · copied symbol auto numbered based on item id scheme....

29
HyDraw ® CAD 2019 What’s New 1 29 of HyDraw CAD 2019 Power-to-Design Circuits What’s New ®

Upload: phungdieu

Post on 25-Jan-2019

221 views

Category:

Documents


0 download

TRANSCRIPT

HyDraw® CAD 2019 What’s New 1 29of

HyDraw CAD 2019

Power-to-Design Circuits

What’s New

®

HyDraw® CAD 2019 What’s New 2 29of

Customized HyDraw Layer Properties Stored in the Drawing

Title Block Attributes Updated using Text File

Display Accessories of Components Excluded from Parts List

Mirror HyDraw schematic

Select Symbol to Insert from Parts List

Warning for Non-Unique Solenoid ID

Parts List Auto-Updated

Group Item ID by Component Code

Properties Equally Spaced in Drawing

Component without Model Code Auto-Grouped

Update Hose ID Text Height

Enhanced Schematic CheckSearch Components by Application Type

HyDraw Ribbon Created using Cuix file

Exclude Multiple Items from Parts List

Change and Update Hose Balloon Type

Inserted Symbol Auto Numbered based on Item ID Scheme

Copied Symbol Auto Numbered based on Item ID Scheme

Network License option available within HyDraw CAD Client

Vertical Stacking option for Item ID and Balloons

ISO 1219-2 Item ID Auto Numbering Scheme Add HyDraw CAD Commands to Quick Access Toolbar

Line Type Preview available for HyDraw Connection Lines

HyDraw® CAD 2019 What’s New!T O C

Edit and Update Blank Fields in Parts List

Define Component Code for a Component Type

HyDraw Library Manager

HyDraw® CAD 2019 What’s New 3 29of

Note:1. Mismatch in component data value with respect to the schematic reflects in the change in text color

in the Parts List to red and appearance of a flag at the start of the row. 2. Update Parts List by right-clicking the Parts List table and selecting ‘Update Parts List’.

Change in a component’s property value reflects in the Parts List:- Flag- Text color changes to red

Parts List Auto-UpdatedNEW

Automatically update the Parts List using theUPDATEPARTLIST command.- Right click on the Parts List or - Use the command line.

HyDraw® CAD 2019 What’s New 4 29of

NEW Inserted Symbols Auto Numbered based on Item ID Scheme

Inserted Symbol is automatically numbered based on the Components & Accessories numbering scheme selected in HyDraw Options, Item ID tab

HyDraw® CAD 2019 What’s New 5 29of

NEW

Note: HyDraw checks the Item ID number of the selected numbering schemeand then assigns the next copied symbol with the number increment by one.

Copied symbol is automatically numbered based on the Components & Accessories numbering scheme selected in HyDraw Options, Item ID tab

Copied Symbols Auto Numberedbased on Item ID Scheme

HyDraw® CAD 2019 What’s New 6 29of

NEW

Item ID grouped based on the Component code assigned to Component types

Component Code assigned for the Component Type in HyDraw Library using HyDraw Library Manager 2019 more…

Group Item ID by Component Code

HyDraw® CAD 2019 What’s New 7 29of

NEW

Text File with Title Block Attributes

Import Title Block Attributes from external text file

Title Block Attributes Updated using Text File

Export Title Block Attributes to external text file

HyDraw® CAD 2019 What’s New 8 29of

NEW

Network License Option is now available within HyDraw CAD Client

Borrow License from HyDraw CAD Client

Check License directly from the client by entering server details

Network License option available within HyDraw CAD Client

HyDraw® CAD 2019 What’s New 9 29of

NEW

Option to search by Application type: Hydraulic, Pneumatic or Electrical is now available in HyDraw Library Explorer

Search Componentsby Application Type

HyDraw® CAD 2019 What’s New 10 29of

NEW

Model Code in Parts List has multiple symbols linked to it in the HyDraw Library

Select an appropriate symbol to insert from the Parts List into the drawing

Select Symbol to Insert from Parts List

HyDraw® CAD 2019 What’s New 11 29of

NEW

Mirror HyDraw Schematic automatically corrects the orientation and position of the texts of Item ID, Properties and Balloons

Note: This is an enhancement to the AutoCAD ‘MIRROR’ command.

Mirror HyDraw Schematic

HyDraw® CAD 2019 What’s New 12 29of

NEW

Accessory Item ID Stacking options in HyDraw Options > Item ID

Note: Option to ‘Stack Vertically’ is now added

Horizontal Stacking of Accessory IDs

Vertical Stacking of Accessory IDs

Vertical Stacking option for Item ID and Balloons

HyDraw® CAD 2019 What’s New 13 29of

NEW

HyDraw stores the prefix and continuously increments the index along with the prefix

Define ISO1219-2 Numbering Scheme for the first symbol

ISO 1219-2 Item ID Auto Numbering Scheme

HyDraw® CAD 2019 What’s New 14 29of

NEW

The spacing between the displayable properties is automatically controlled

Properties Equally Spaced in Drawing

HyDraw CAD 2018 HyDraw CAD 2019

Empty space appears for hidden displayable properties

HyDraw® CAD 2019 What’s New 15 29of

NEW

For components without model code, all identical components are grouped on the basis of properties listed in the Parts List

Components without Model Code Auto-Grouped

HyDraw® CAD 2019 What’s New 16 29of

NEW

Double Click and enter required properties in the blank cells and Update the Parts List

Note: The Model Data linked to the symbol in the drawing will also get updated if the Parts List is updated.

Edit and Update Blank Fields in Parts List

HyDraw® CAD 2019 What’s New 17 29of

NEW

Update Hose ID Text Height

Update Hose ID Text Height

HyDraw® CAD 2019 What’s New 18 29of

NEW

Change and Update Hose Balloon Type

Update Balloon Type for Hoses

Set Separate Balloon Type for Hoses

HyDraw® CAD 2019 What’s New 19 29of

NEW

Warning message is displayed to indicate duplicate Solenoid IDs, when chart is created without Item ID as an option

Warning for Non-Unique Solenoid ID

HyDraw® CAD 2019 What’s New 20 29of

NEW

Schematic check for Envelopes added

Unconnected ends of External Ports listed

Validation of Connection Error

Enhanced Schematic Check

HyDraw® CAD 2019 What’s New 21 29of

NEW

Changes made to the layer properties in the drawing are stored and not overwritten by the default HyDraw layer properties when a new symbol is inserted into the drawing

Customized HyDraw Layer Properties Stored in the Drawing

HyDraw® CAD 2019 What’s New 22 29of

NEW

Multiple Component selection in the drawing can be excluded from the Parts List

Exclude Multiple Items from Parts List

HyDraw® CAD 2019 What’s New 23 29of

Note: You can now exclude a component from the Parts List and not exclude its linked accessories.

NEW Display Accessories of Components Excluded from Parts List

Accessory is still displayed in the drawing

Component included in Parts List

Component not included in Parts List

HyDraw® CAD 2019 What’s New 24 29of

NEW

Add to Quick Access Toolbar by right-clicking the HyDraw CAD command on the ribbon menu

Newly added HyDraw CAD command displays on the Quick Access Toolbar

Add HyDraw CAD Commands to Quick Access Toolbar

HyDraw® CAD 2019 What’s New 25 29of

NEW

Line Type Preview now available for HyDraw CAD Connection Lines

Line Type Preview available forHyDraw Connection Lines

HyDraw® CAD 2019 What’s New 26 29of

NEW

HyDraw Ribbon menu created using CUIX file.This enables “Add to Quick Access” toolbar and any customizations made to the interface are stored and available in a new instance of HyDraw.

HyDraw Ribbon Created using CUIX file

HyDraw® CAD 2019 What’s New 27 29of

HyDraw Library Manager

HyDraw® CAD 2019 What’s New 28 29of

NEW

Note: This is used for assigning Item IDs in the drawing.

Define Component code for a Component Typemore…

Define Component Codefor a Component Type

HyDraw® CAD 2019 What’s New 29 29of

C ontac t VEST Do more…

HyDraw CAD 2019circuit design app

HyDraw CAD 2019 Free Evaluation

For more information, contact VEST

Call +1 (248) 649-9550, or email [email protected]

In Europe, Call +39 328 695 70 01 or email [email protected]

®

v180707 © 2018 VEST, Inc. All rights reserved