hydraw cad 2019 - vestusa.coms-new.pdf · copied symbol auto numbered based on item id scheme....
TRANSCRIPT
HyDraw® CAD 2019 What’s New 2 29of
Customized HyDraw Layer Properties Stored in the Drawing
Title Block Attributes Updated using Text File
Display Accessories of Components Excluded from Parts List
Mirror HyDraw schematic
Select Symbol to Insert from Parts List
Warning for Non-Unique Solenoid ID
Parts List Auto-Updated
Group Item ID by Component Code
Properties Equally Spaced in Drawing
Component without Model Code Auto-Grouped
Update Hose ID Text Height
Enhanced Schematic CheckSearch Components by Application Type
HyDraw Ribbon Created using Cuix file
Exclude Multiple Items from Parts List
Change and Update Hose Balloon Type
Inserted Symbol Auto Numbered based on Item ID Scheme
Copied Symbol Auto Numbered based on Item ID Scheme
Network License option available within HyDraw CAD Client
Vertical Stacking option for Item ID and Balloons
ISO 1219-2 Item ID Auto Numbering Scheme Add HyDraw CAD Commands to Quick Access Toolbar
Line Type Preview available for HyDraw Connection Lines
HyDraw® CAD 2019 What’s New!T O C
Edit and Update Blank Fields in Parts List
Define Component Code for a Component Type
HyDraw Library Manager
HyDraw® CAD 2019 What’s New 3 29of
Note:1. Mismatch in component data value with respect to the schematic reflects in the change in text color
in the Parts List to red and appearance of a flag at the start of the row. 2. Update Parts List by right-clicking the Parts List table and selecting ‘Update Parts List’.
Change in a component’s property value reflects in the Parts List:- Flag- Text color changes to red
Parts List Auto-UpdatedNEW
Automatically update the Parts List using theUPDATEPARTLIST command.- Right click on the Parts List or - Use the command line.
HyDraw® CAD 2019 What’s New 4 29of
NEW Inserted Symbols Auto Numbered based on Item ID Scheme
Inserted Symbol is automatically numbered based on the Components & Accessories numbering scheme selected in HyDraw Options, Item ID tab
HyDraw® CAD 2019 What’s New 5 29of
NEW
Note: HyDraw checks the Item ID number of the selected numbering schemeand then assigns the next copied symbol with the number increment by one.
Copied symbol is automatically numbered based on the Components & Accessories numbering scheme selected in HyDraw Options, Item ID tab
Copied Symbols Auto Numberedbased on Item ID Scheme
HyDraw® CAD 2019 What’s New 6 29of
NEW
Item ID grouped based on the Component code assigned to Component types
Component Code assigned for the Component Type in HyDraw Library using HyDraw Library Manager 2019 more…
Group Item ID by Component Code
HyDraw® CAD 2019 What’s New 7 29of
NEW
Text File with Title Block Attributes
Import Title Block Attributes from external text file
Title Block Attributes Updated using Text File
Export Title Block Attributes to external text file
HyDraw® CAD 2019 What’s New 8 29of
NEW
Network License Option is now available within HyDraw CAD Client
Borrow License from HyDraw CAD Client
Check License directly from the client by entering server details
Network License option available within HyDraw CAD Client
HyDraw® CAD 2019 What’s New 9 29of
NEW
Option to search by Application type: Hydraulic, Pneumatic or Electrical is now available in HyDraw Library Explorer
Search Componentsby Application Type
HyDraw® CAD 2019 What’s New 10 29of
NEW
Model Code in Parts List has multiple symbols linked to it in the HyDraw Library
Select an appropriate symbol to insert from the Parts List into the drawing
Select Symbol to Insert from Parts List
HyDraw® CAD 2019 What’s New 11 29of
NEW
Mirror HyDraw Schematic automatically corrects the orientation and position of the texts of Item ID, Properties and Balloons
Note: This is an enhancement to the AutoCAD ‘MIRROR’ command.
Mirror HyDraw Schematic
HyDraw® CAD 2019 What’s New 12 29of
NEW
Accessory Item ID Stacking options in HyDraw Options > Item ID
Note: Option to ‘Stack Vertically’ is now added
Horizontal Stacking of Accessory IDs
Vertical Stacking of Accessory IDs
Vertical Stacking option for Item ID and Balloons
HyDraw® CAD 2019 What’s New 13 29of
NEW
HyDraw stores the prefix and continuously increments the index along with the prefix
Define ISO1219-2 Numbering Scheme for the first symbol
ISO 1219-2 Item ID Auto Numbering Scheme
HyDraw® CAD 2019 What’s New 14 29of
NEW
The spacing between the displayable properties is automatically controlled
Properties Equally Spaced in Drawing
HyDraw CAD 2018 HyDraw CAD 2019
Empty space appears for hidden displayable properties
HyDraw® CAD 2019 What’s New 15 29of
NEW
For components without model code, all identical components are grouped on the basis of properties listed in the Parts List
Components without Model Code Auto-Grouped
HyDraw® CAD 2019 What’s New 16 29of
NEW
Double Click and enter required properties in the blank cells and Update the Parts List
Note: The Model Data linked to the symbol in the drawing will also get updated if the Parts List is updated.
Edit and Update Blank Fields in Parts List
HyDraw® CAD 2019 What’s New 18 29of
NEW
Change and Update Hose Balloon Type
Update Balloon Type for Hoses
Set Separate Balloon Type for Hoses
HyDraw® CAD 2019 What’s New 19 29of
NEW
Warning message is displayed to indicate duplicate Solenoid IDs, when chart is created without Item ID as an option
Warning for Non-Unique Solenoid ID
HyDraw® CAD 2019 What’s New 20 29of
NEW
Schematic check for Envelopes added
Unconnected ends of External Ports listed
Validation of Connection Error
Enhanced Schematic Check
HyDraw® CAD 2019 What’s New 21 29of
NEW
Changes made to the layer properties in the drawing are stored and not overwritten by the default HyDraw layer properties when a new symbol is inserted into the drawing
Customized HyDraw Layer Properties Stored in the Drawing
HyDraw® CAD 2019 What’s New 22 29of
NEW
Multiple Component selection in the drawing can be excluded from the Parts List
Exclude Multiple Items from Parts List
HyDraw® CAD 2019 What’s New 23 29of
Note: You can now exclude a component from the Parts List and not exclude its linked accessories.
NEW Display Accessories of Components Excluded from Parts List
Accessory is still displayed in the drawing
Component included in Parts List
Component not included in Parts List
HyDraw® CAD 2019 What’s New 24 29of
NEW
Add to Quick Access Toolbar by right-clicking the HyDraw CAD command on the ribbon menu
Newly added HyDraw CAD command displays on the Quick Access Toolbar
Add HyDraw CAD Commands to Quick Access Toolbar
HyDraw® CAD 2019 What’s New 25 29of
NEW
Line Type Preview now available for HyDraw CAD Connection Lines
Line Type Preview available forHyDraw Connection Lines
HyDraw® CAD 2019 What’s New 26 29of
NEW
HyDraw Ribbon menu created using CUIX file.This enables “Add to Quick Access” toolbar and any customizations made to the interface are stored and available in a new instance of HyDraw.
HyDraw Ribbon Created using CUIX file
HyDraw® CAD 2019 What’s New 28 29of
NEW
Note: This is used for assigning Item IDs in the drawing.
Define Component code for a Component Typemore…
Define Component Codefor a Component Type
HyDraw® CAD 2019 What’s New 29 29of
C ontac t VEST Do more…
HyDraw CAD 2019circuit design app
HyDraw CAD 2019 Free Evaluation
For more information, contact VEST
Call +1 (248) 649-9550, or email [email protected]
In Europe, Call +39 328 695 70 01 or email [email protected]
®
v180707 © 2018 VEST, Inc. All rights reserved