hydronex dvip panel - watts

2
DVIP panels use injection reset mixing to modulate the supply fluid temperature to the radiant zones. The injection bridge is 3/4" in size for all DVIP panels. All zones are 3/4" supply with a common 1" return. A Tekmar 361 is provided to control the injection circulator. When selecting a DVIP panel, the following guidelines should be followed: – Make sure all zones fall within a 20 degree required temperature range. (i.e. 110, 114, 125 supply temperature requirements can be grouped from a single injection circulator). – The combined zone gpm can not exceed 20 gpm. Installation Parameters Make sure an electrical outlet is within 3 feet of where the DVIP panel will mount. If there are no outlets, one will need to be added. Install and level Z-Bracket with 1/4" x 2-1/2" lag screw to studs. Make sure the Z-Bracket is the correct size for the given DVIP panel. Incorrect Z-Brackets may interfere with cover placement. Hang the DVIP panel on the Z-Bracket. Lag screws should be added to the bottom of the panel, further securing the panel to the wall. Hang cover from top down. In order to avoid property damage, injury, and/or death, please refer to the complete installation manual and warnings provided with the product. For Residential, Light Commercial, and Snow Melt Applications Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– HydroNex ® DVIP Panel Sizes: 1-1/4" Trunk; 3/4" Zone Supply; 1" Common Return Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Specifications Supply Voltage 120 Volts Circulator Type Watts Radiant 15-58 Taco 007 Bell and Gossett NRF-22 Electrical Relay and CAT-5 Connection Injection/Reset Control Tekmar 361 Temperature, Pressure Ratings 210ºF @ 100 psi. Features Wall mounted white powder coated back panel and cover Easy access to all components Pre-wired circulators and controls Simple CAT-5 jump wiring to connect panels O-Ring sealed, threaded union connection between panels Integrated leveling system Z-Bracket for simplified mounting ES-WR-HydroNex DVIP

Upload: others

Post on 01-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HydroNex DVIP Panel - Watts

DVIP panels use injection reset mixing to modulate the supply fluid temperature to the radiant zones. The injection bridge is 3/4" in size for all DVIP panels. All zones are 3/4" supply with a common 1" return.

A Tekmar 361 is provided to control the injection circulator.

When selecting a DVIP panel, the following guidelines should be followed: – Make sure all zones fall within a 20 degree required

temperature range. (i.e. 110, 114, 125 supply temperature requirements can be grouped from a single injection circulator).

– The combined zone gpm can not exceed 20 gpm.

Installation ParametersMake sure an electrical outlet is within 3 feet of where the DVIP panel will mount. If there are no outlets, one will need to be added.

Install and level Z-Bracket with 1/4" x 2-1/2" lag screw to studs. Make sure the Z-Bracket is the correct size for the given DVIP panel. Incorrect Z-Brackets may interfere with cover placement.

Hang the DVIP panel on the Z-Bracket. Lag screws should be added to the bottom of the panel, further securing the panel to the wall. Hang cover from top down.

In order to avoid property damage, injury, and/or death, please refer to the complete installation manual and warnings provided with the product.

For Residential, Light Commercial, and Snow Melt Applications

Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location ––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––

HydroNex® DVIP PanelSizes: 1-1/4" Trunk; 3/4" Zone Supply; 1" Common Return

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

SpecificationsSupply Voltage 120 Volts

Circulator TypeWatts Radiant 15-58Taco 007Bell and Gossett NRF-22

Electrical Relay and CAT-5 ConnectionInjection/Reset Control Tekmar 361Temperature, Pressure Ratings 210ºF @ 100 psi.

FeaturesWall mounted white powder coated back panel and coverEasy access to all componentsPre-wired circulators and controlsSimple CAT-5 jump wiring to connect panelsO-Ring sealed, threaded union connection between panelsIntegrated leveling systemZ-Bracket for simplified mounting

ES-WR-HydroNex DVIP

Page 2: HydroNex DVIP Panel - Watts

USA: 4500 East Progress Place, Springfield, MO 65803; www.wattsradiant.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca

HydroNex DVIP 3 zone panel. DVIP series are available from 1 to 5 zones.

Description Model # Wt. (lbs) Size1 Zone DVIP DI - ____ - 1 85-90 S2 Zone DVIP DI - ____ - 2 120-125

M3 Zone DVIP DI - ____ - 3 140-1454 Zone DVIP DI - ____ - 4 170-175

L5 Zone DVIP DI - ____ - 5 200-205

S = 28" wide x 31.5" tall x 12" deep M = 40" wide x 31.5" tall x 12" deep L = 52" wide x 31.5" tall x 12" deep

# of Zones1, 2, 3, 4, or 5

DI

Secondary and Injection Circulator Options1. Watts Radiant 15582. B&G NRF 223. Taco 007

GROUND SCREW

P3

WH

ITE

ZONE 1 ZONE 2

ZONE 2 ZONE 3

BLACK

WHITE

GREEN

BLA

CK

P4

WH

ITE

BLA

CK

RED

WHITE

8 7 2 1

5436

BROWN ORANGE

BLUEGREEN

WHITEBROWN

WHITEGREEN

WHITEORANGE

WHITEBLUE

TAB

UP

RE

D

WH

ITE

BLU

E

GR

EE

N

8 7 2 1

5436

BROWN ORANGE

BLUEGREEN

WHITEBROWN

WHITEGREEN

WHITEORANGE

WHITEBLUE

TAB

UP

BLU

E GR

EEN

RE

D

WH

ITE

WH

ITE

RE

D

RE

D

WH

ITE

BLU

E

GR

EE

N

8 7 2 1

5436

BROWN ORANGE

BLUEGREEN

WHITEBROWN

WHITEGREEN

WHITEORANGE

WHITEBLUE

TAB

UP

BLU

E GR

EEN

RE

D

WH

ITE

WH

ITE

RE

D

171615141312UnO

11

Do not apply power

8

N

SR

504-

EX

P

POWERINPUT

PLUG-IN CARDS

ZONE 3 ZONE 4

ZONE 1 ZONE 4

WHITE

BLA

CK

WH

ITE

GROUND SCREW

P3

BLA

CK

WH

ITE

ZONE 3 ZONE 4

ZONE 2 ZONE 3

WH

T

BLACK

WHITE

GREEN

Priority ZoneSmall

Buchanan

R W 24VAC

3N H 4 N

C4

NO

SR

504-

EX

P

POWERINPUT

PLUG-IN CARDS

ZONE 2

ZONE 1 ZONE 4

RED

BLA

CK

WH

ITE

BLA

CK

WH

ITE

6 N

C6

NC

5 N

C

T T COM

TACOSR501

WHITE

P1

BLACK

BLK

GROUND SCREWGREEN

GREEN

GREEN

WHITE

P1P2

BLA

CK

WH

ITE

RED

ZONE 4PRIORITY

Transformer

MASTER

1 AMP FUSE

PCI

24VACPOWER

SLAVE

ON 1 2 3 4OFF

RESET NORMAL

120VRELAY

ZRXX ZC

EXPANSION

Sys

54Power

3

Pmp

2

Demand

1Mix

361

LN

10Boiler

9Var

7

Pmp

6

NComBoil Mix ComOut Indr

Sw

P1P2

INJREDWHITE

BLA

CK

WH

ITE

RED

BLA

CK

WH

ITE

ZONE 4PRIORITY

Transformer

MASTER

1 AMP FUSE

PCI

24VACPOWER

SLAVE

ONZONE 1 1 2 3 4OFF

RESET NORMAL

120VRELAY

ZRXX ZC

EXPANSION

HydroNex DVIP 3 zone panel Schematic

ES-WR-HydroNex DVIP 1109 © 2011 Watts Radiant