Services “Radiology Update Seminar
for The Dental Team”
Dr. Richard DeCann & Mr. Tim Reynolds IMECS Radiography Consultants Tel:07855 183117 email: [email protected]
www.imecs-cpd.co.uk
![Page 2: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/2.jpg)
What do dentists need to know?
• UK radiation dose distributions• Nature and effects of radiation• Clinical implications of IRR1999 and
IR(ME)R 2000• Patient safety and selection criteria• Optimisation of radiographic techniques• Quality assurance and record keeping
www.imecs-cpd.co.uk
![Page 3: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/3.jpg)
What do nurses need to know?
• Principle foundations of dental radiographic techniques
• Equipment used• Methods of processing films and the
practice of digital radiography• Hazards of exposure to ionising radiations• Have an understanding of the regulatory
requirements
www.imecs-cpd.co.uk
![Page 4: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/4.jpg)
What must nurses be able to do?
• Prepare the equipment and materials• Prepare and care for patients• Process radiographs• Properly mount radiographs• Undertake quality assurance measures in
processing
www.imecs-cpd.co.uk
![Page 5: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/5.jpg)
The Discovery of X-Rays
Prof. W. RoentgenNovember 1895
www.imecs-cpd.co.uk
![Page 6: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/6.jpg)
UK Dose Distribution
83%
17%
Comparison between dose sources in the UK
www.imecs-cpd.co.uk
![Page 7: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/7.jpg)
Man Made Dose Distribution
90%
10%
• Medical dose compared with other man made sources
www.imecs-cpd.co.uk
![Page 8: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/8.jpg)
Comparing Medical Doses
97%
3%
• General medical dose compared with dental
www.imecs-cpd.co.uk
![Page 9: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/9.jpg)
Radiological Examinations in the UK
30%
70%
• Number of general medical examinations compared with dental
www.imecs-cpd.co.uk
![Page 10: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/10.jpg)
Potential for Dose Saving
10%
45%
45%• Up to 50% of the medical dose delivered in
the UK is unnecessary
www.imecs-cpd.co.uk
![Page 11: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/11.jpg)
Workshop
• List the characteristics of x-rays e.g. travels in straight lines
www.imecs-cpd.co.uk
![Page 12: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/12.jpg)
Nature of Ionising Radiation
• Travels in straight lines at the speed of light• Obeys the inverse square law• Penetrates, excites and ionises matter• Chemical and biological effect• Photographic and fluoroscopic effect• Unaffected by magnetic or electric fields
www.imecs-cpd.co.uk
![Page 13: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/13.jpg)
Electromagnetic Spectrum
low high
Energy
radiowaves
visible light
cosmic rays
microwaves
X & gamma rays
www.imecs-cpd.co.uk
![Page 14: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/14.jpg)
X-Ray Tube
anodecathode
target
X-ray beam
electron beam
![Page 15: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/15.jpg)
Workshop
• What units are used to measure radiation exposure and dose ?
www.imecs-cpd.co.uk
![Page 16: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/16.jpg)
Units of Radiation Measurement
• Exposure = COULOMBS PER KILOGRAM Kinetic Energy Released per unit Mass (KERMA)
• Absorbed Dose = GRAY Joules per Kilogram
www.imecs-cpd.co.uk
![Page 17: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/17.jpg)
Dose Reference Levels• PA DRLs DOH 4Mgy
HPA 2mGyRecommended 1 – 1.5mGy
OPG DRLs DOH 66mGyHPA 20mGy
Recommended 10 – 15mGy
![Page 18: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/18.jpg)
Units of Radiation Measurement
• Exposure = COULOMBS PER KILOGRAM Kinetic Energy Released per unit Mass (KERMA)
• Absorbed Dose = GRAY Joules per Kilogram
• Dose Equivalent = SIEVERT Gray x Q (x-rays=1, protons=10, alpha=20)
• Effective Dose = SIEVERT Biological Effect (dose equivalent x tissue sensitivity)
www.imecs-cpd.co.uk
![Page 19: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/19.jpg)
Dose Reference Levels• PA DRLs DOH 4Mgy
HPA 2mGyRecommended 1 – 1.5mGy(Effective dose 0.002mSv)
OPG DRLs DOH 66mGyHPA 20mGy
Recommended 10 – 15mGy(Effective dose 0.007mSv)
![Page 20: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/20.jpg)
Units of Radiation Measurement
• Exposure = COULOMBS PER KILOGRAM Kinetic Energy Released per unit Mass (KERMA)
• Absorbed Dose = GRAY Joules per Kilogram
• Dose Equivalent = SIEVERT Gray x Q (x-rays=1, protons=10, alpha=20)
• Effective Dose = SIEVERT Biological Effect (dose equivalent x tissue sensitivity)
www.imecs-cpd.co.uk
![Page 21: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/21.jpg)
Round collimator at 6cms diameter = 29cm
![Page 22: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/22.jpg)
DRL = mGy/cm2
![Page 23: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/23.jpg)
DRL = mGy/cm2
![Page 24: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/24.jpg)
Thyroid collars
![Page 25: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/25.jpg)
Effective Dose and Kilo-voltage
• 60 kV 70kV
![Page 26: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/26.jpg)
Excitation and Ionisation
![Page 27: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/27.jpg)
Excitation and Ionisation
X-ray photon
![Page 28: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/28.jpg)
Excitation and Ionisation
X-ray photon
Ionised electron
![Page 29: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/29.jpg)
Excitation and Ionisation
![Page 30: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/30.jpg)
Excitation and Ionisation
![Page 31: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/31.jpg)
Excitation and Ionisation
![Page 32: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/32.jpg)
Radiobiology
• Random interactions causing direct and indirect tissue damage
• Critical body macromolecules: protein, DNA (damage with incomplete or misrepair)
• H2O affected because of large size and content• Ionised water becomes chemically reactive and
can affect DNA by indirect action• Formation of free radicals:
HO2 (peroxyls) H2O2 (peroxides)
www.imecs-cpd.co.uk
![Page 33: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/33.jpg)
Ionisation and free radicals
• RH + Radiation = RH+ + electron
R H
H2O HO H
![Page 34: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/34.jpg)
RadiobiologyThe exposure of a cell to radiation may result in:
• The premature death of the cell• Prevention or delay in cell division• Changes in cell structure and/or functions
which may be passed on to daughter cells
www.imecs-cpd.co.uk
![Page 35: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/35.jpg)
What is damaged?
• DNA
• Any of the cytoplasmic organelles
• I bet they say MITOCHONDRIA
www.imecs-cpd.co.uk
![Page 36: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/36.jpg)
What Type of Damage Can Occur?
• Stochastic• Deterministic
www.imecs-cpd.co.uk
![Page 37: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/37.jpg)
Who is Affected?
• Somatic• Genetic
www.imecs-cpd.co.uk
![Page 38: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/38.jpg)
Variations with Age at Exposure
Detriment vs Age at Exposure
0 to 5years
5 to 10years
10 to 20years
20 to 30years
30 to 40years
40 to 50years
50 to 60years
www.imecs-cpd.co.uk
![Page 39: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/39.jpg)
Integrated
Management &
Educational
Consultancy
Services “Radiology Update Seminar
for The Dental Team”
Dr. Richard DeCann & Mr. Tim Reynolds IMECS Radiography Consultants Tel:07855 183117 email: [email protected]
www.imecs-cpd.co.uk
![Page 40: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/40.jpg)
Legislative Framework
• Two sets of regulations have been introduced in the UK in the last 13 years
• Ionising Radiations Regulations 1999 (IRR 99)
• Ionising Radiations (Medical Exposures) Regulations 2000 (IR(ME)R 2000)
www.imecs-cpd.co.uk
![Page 41: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/41.jpg)
IRR 1999
• Is about:– Environment– Workers – Members of the public
www.imecs-cpd.co.uk
![Page 42: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/42.jpg)
Public Protection
![Page 43: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/43.jpg)
IRR 1999
• Is about:– Environment– Workers – Members of the public– Management of radiationm protection
www.imecs-cpd.co.uk
![Page 44: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/44.jpg)
IRR 1999
• HSE notification • Risk assessment
www.imecs-cpd.co.uk
![Page 45: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/45.jpg)
Risk Assessment
Window
Exposure Switch
Mains isolator
4M
Surgery 2
Waiting room
![Page 46: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/46.jpg)
Staff Risk Assessment
![Page 47: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/47.jpg)
Staff Risk Assessment
![Page 48: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/48.jpg)
IRR 1999
• HSE notification • Risk assessment• Contingency plans• Dose restriction/limitation• Training• RPS/RPA • Controlled areas
www.imecs-cpd.co.uk
![Page 49: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/49.jpg)
Controlled areas
![Page 50: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/50.jpg)
?Fire regulations
![Page 51: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/51.jpg)
How MUCH Lead ?
![Page 52: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/52.jpg)
IR(ME)R 2000
Is about:
• Patient protection
www.imecs-cpd.co.uk
![Page 53: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/53.jpg)
Ionising Radiation (Medical Exposures) Regulations 2000
Summary
• Justification– Patient examination, identify clinical reason, written report
• Optimisation– Maximum yield with minimal dose
• Entitlement– Anyone can do anything as long as they are trained and it is agreed
and monitored
www.imecs-cpd.co.uk
![Page 54: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/54.jpg)
Selection (Referral)Criteria
• SELECTIVE– Symptomatic to confirm or refute
• ROUTINE– Circumstantial evidence
• SCREENING– No evidence
www.imecs-cpd.co.uk
![Page 55: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/55.jpg)
Optimisation
• Patient ID• Patient care• Check history, area• Admin• Justification• 70kV DC• Film holders
• Rectangular collimators• Film speed• Viewing• Maintenance & QA
– Equipment– Processor
• Audit• Training
www.imecs-cpd.co.uk
![Page 56: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/56.jpg)
Digital Dental Radiography
• Direct– Charge Coupled Devices / CMOS – (wired systems)
• Indirect– Photo phosphor plates
www.imecs-cpd.co.uk
![Page 57: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/57.jpg)
Digital Image Processing
• Analysis– Collect numeric information based on the image
• Enhancement– Improve appearance of image
• Encoding– Reduce information required to describe the image
www.imecs-cpd.co.uk
![Page 58: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/58.jpg)
Ionising Radiation (Medical Exposures) Regulations 2000
Conceptual Framework• Clinical audit
– Radiographic and Radiological
• Expert advice– Medical Physics Expert
• Equipment inventory– Radiation Protection File
• Training– What, how and assessed
• Enforcement– Health & Safety @ Work
www.imecs-cpd.co.uk
![Page 59: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/59.jpg)
Justification of an individual medical exposure
• No person shall carry out a medical exposure unless:
– It has been justified by a practitioner as showing sufficient net benefit.
– It has been authorised by a practitioner (where appropriate the operator)
– Has been authorised by the local research/ethics committee– It is a part of an agreed medico-legal procedure– In the case of a female of childbearing age, he has enquired
whether she is pregnant, if relevant.
www.imecs-cpd.co.uk
![Page 60: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/60.jpg)
Ionising Radiation (Medical Exposures) Regulations 2000
• Employer• Referrer/Prescriber• Practitioner• Operator
www.imecs-cpd.co.uk
![Page 61: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/61.jpg)
Duty of Role Holders
• Employer: to provide a framework for radiation protection of the patient through provision of standard operating procedures.
• Referrer/Prescriber: to provide sufficient relevant clinical information on the patient to enable the justification of the medical exposure.
• Practitioner: to justify each individual medical exposure.• Operator: to undertake practical aspects of the medical
exposure.
www.imecs-cpd.co.uk
![Page 62: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/62.jpg)
Employer
• Any natural or legal person who, in the course of a trade, business or other undertaking, carries out (other than as an employee), or engages others to carry out, medical exposures or practical aspects, at a given radiological installation.
www.imecs-cpd.co.uk
![Page 63: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/63.jpg)
Employer Procedures for Dentists
• Protocols and/or guidelines for:– Patient identification– Competencies of practitioners & operators– Medico-legal exposures– Women of childbearing age– Reduce accidental exposure to ALARP
• Expected doses and dose recording• Quality assurance
www.imecs-cpd.co.uk
![Page 64: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/64.jpg)
Referrer
• A registered medical or dental practitioner, or other health care professional who is entitled in accordance with the employer’s procedures to refer individuals for a medical exposure to a practitioner.
www.imecs-cpd.co.uk
![Page 65: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/65.jpg)
Practitioner
• A registered medical or dental practitioner, or other health professional who is entitled, in accordance with the employer’s procedures, to take responsibility for an individual medical exposure.
www.imecs-cpd.co.uk
![Page 66: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/66.jpg)
Operator
• Any person who is entitled, in accordance with the employer’s procedures, to carry out practical aspects (including those to whom practical aspects have been allocated) except, when training, where they do so under the direct supervision of a person who is adequately trained.
www.imecs-cpd.co.uk
![Page 67: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/67.jpg)
Adequate Training
• Practitioners and operators shall have successfully completed training, including theoretical knowledge and practical experience (in radiation protection and diagnostic or therapeutic techniques involving ionising radiation) appropriate to their specific area of practice.
www.imecs-cpd.co.uk
![Page 68: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/68.jpg)
Quality AssurancePrimary FunctionsüConsistently high quality imagesüDoses to staff and patients are as low as reasonably practicable
Key Elementsü Darkroom, film and processingüX-ray equipmentü Working proceduresü Audits & Quality Targets
www.imecs-cpd.co.uk
![Page 69: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/69.jpg)
Darkroom
• Film storage and stock rotation
• Light tight integrity (visual)
• Safelight (coin test)
www.imecs-cpd.co.uk
![Page 70: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/70.jpg)
Quality Control:Equipment MonitoringWeekly clean with spirit based solution and checks for:
• Electrical: sockets, plugs, earthing, insulation, leads (mains, exposure), tube head (leaks).
www.imecs-cpd.co.uk
![Page 71: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/71.jpg)
Quality Control:Equipment MonitoringWeekly clean with spirit based solution and checks for:
• Electrical: sockets, plugs, earthing, insulation, leads (mains, exposure), tube head (leaks).
• Mechanical: mountings, support, brakes, stability, fixtures and fittings (collimators).
• Radiation: output checks (annual), tube head (dents), mains isolation switch
www.imecs-cpd.co.uk
![Page 72: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/72.jpg)
Trophy 70 Room 2 June 2010 5.6.10 12.6.10 19.6.10 26.6.10
Electrical
Socket
Plug
Leads
Tubes leaks
Mechanical Security
Wall support
Tube arm
Tube head
Cone/collimators
Radiation
Tube dents
Mains isolation
Signature
Date
www.imecs-cpd.co.uk
![Page 73: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/73.jpg)
Quality Control:Processor MonitoringWeekly clean with checks for:
• Electrical: sockets, plugs, leads, earthing and insulation.
• Lightproof: lid, feed cover, light screen (coin test)
• Transport: rollers and screens, daily cleaner.
• Image quality: temperature (heater, thermostat), activity (replenishment), wash, drainage, cleanliness, stepped wedge test.
www.imecs-cpd.co.uk
![Page 74: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/74.jpg)
Velopex June 2006 5.6.06 12.6.06 19.6.06 26.6.06
Electrical
Socket
Plug
Leads
Lightproof
Lid
Sleeves
Daily Cleaner
Daily water drain
Stepped wedge
Signature
Date
www.imecs-cpd.co.uk
![Page 75: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/75.jpg)
Stepped Wedge
This is what the wedge looks like
This is what a picture of it should look like
www.imecs-cpd.co.uk
![Page 76: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/76.jpg)
www.imecs-cpd.co.uk
![Page 77: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/77.jpg)
Accessory Equipment
• Cassettes• Screens• Viewing boxes• Film holders
www.imecs-cpd.co.uk
![Page 78: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/78.jpg)
Quality rating and quality standards for radiographs
Rating/Quality Basis
1. Excellent: No errors of exposure, positioning or processing. Not less than 70%.
2. Acceptable Some errors which do not detract from the diagnostic use. Not greater than 20%.
3. Unacceptable Errors which render the radiograph diagnostically unacceptable.
Not greater than 10%.www.imecs-cpd.co.uk
![Page 79: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/79.jpg)
Guidelines for Image Critiques
• Area: film position and orientation
(axis, border, blip)
• Projection: beam centring and
angulation
www.imecs-cpd.co.uk
![Page 80: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/80.jpg)
Critique• Projection: beam centring and angulation
• (no cone cut, crowns in profile/3mm border, no
interproximal overlap, bite block in profile)
3 mm
![Page 81: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/81.jpg)
Guidelines for Image Critiques
• Area: film position and orientation (axis, border, blip)
• Projection: beam centring and angulation
• Density: level of blackness
• Contrast: difference in density for a range of structures
• Sharpness: level of detail
• Artifacts: something on the film that shouldn’t be there
www.imecs-cpd.co.uk
![Page 82: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/82.jpg)
Orthopantomography
![Page 83: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/83.jpg)
Plain Radiography
![Page 84: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/84.jpg)
Scanography
![Page 85: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/85.jpg)
Scanography
![Page 86: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/86.jpg)
Plain Radiography
![Page 87: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/87.jpg)
Tomography
![Page 88: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/88.jpg)
Tomography
![Page 89: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/89.jpg)
Focal Trough
Focal troughPivotal Plane
![Page 90: I ntegrated M anagement & E ducational C onsultancy S ervices](https://reader035.vdocuments.net/reader035/viewer/2022062501/56816974550346895de14fcf/html5/thumbnails/90.jpg)
Principles of Radiation Protection
• Justification of the exposure• Positive identification of the patient• Reference to existing radiological records• Shielding: primary & secondary barriers• Distance• Beam restriction• Minimum number of personnel in the examination room• Quality assurance of all equipment and audit of activities• Choice of x-ray and imaging equipment
www.imecs-cpd.co.uk